NEC Electronics America Computer Hardware 2000 IVS User Manual

ND-45504 (E)  
ISSUE 2  
PART OF STOCK # 151900  
®
Circuit Card Manual  
DECEMBER, 1997  
NEC America, Inc.  
ADD. No.  
ADD. No.  
PAGE No.  
PAGE No.  
001 002 003 004 005 006 007 008  
001 002 003 004 005 006 007 008  
i
2.2  
2.1  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
65-1  
65-2  
65-3  
65-4  
66  
67  
68  
2.2  
2.2  
ii  
iii  
iv  
1
2.2  
2
2.1  
2.2  
2.2  
3
2.2  
2.1  
4
5
2.1  
6
7
8
9
2.2  
2.2  
2.2  
2.2  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
2.1  
2.1  
2.2  
2.1  
2.1  
2.1  
2.1  
2.1  
2.2  
2.1  
2.2  
2.2  
2.2  
2.1  
ADDENDUM-001  
JULY, 1998  
ADDENDUM-002  
OCTOBER, 1998  
ADDENDUM-006  
ADDENDUM-003  
ADDENDUM-004  
ADDENDUM-008  
DATE  
DATE  
DATE  
DATE  
DATE  
DATE  
DATE  
DATE  
ADDENDUM-005  
ADDENDUM-007  
NEAX2000 IVS  
Circuit Card Manual  
Addendum Revision Sheet 1/2  
ND-45504 (E) ISSUE 2  
ADD. No.  
ADD. No.  
PAGE No.  
PAGE No.  
001 002 003 004 005 006 007 008  
001 002 003 004 005 006 007 008  
68-1  
68-2  
68-3  
68-4  
69  
2.1  
2.1  
2.1  
2.1  
97  
98  
99  
100  
101  
102  
103  
104  
105  
106  
107  
108  
109  
110  
111  
112  
113  
114  
115  
116  
117  
118  
119  
120  
121  
122  
123  
124  
125  
126  
127  
128  
129  
130  
131  
132  
133  
134  
70  
2.1  
2.1  
71  
72  
73  
74  
75  
76  
77  
78  
78-1  
78-2  
78-3  
78-4  
78-5  
78-6  
79  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
ADDENDUM-001  
JULY, 1998  
ADDENDUM-005  
ADDENDUM-002  
OCTOBER, 1998  
ADDENDUM-006  
ADDENDUM-003  
ADDENDUM-004  
ADDENDUM-008  
DATE  
DATE  
DATE  
DATE  
DATE  
DATE  
ADDENDUM-007  
DATE  
DATE  
NEAX2000 IVS  
Circuit Card Manual  
Addendum Revision Sheet 2/2  
ND-45504 (E) ISSUE 2  
ND-45504 (E)  
ISSUE 2  
DECEMBER, 1997  
NEAX2000 IVS  
Circuit Card Manual  
TABLE OF CONTENTS  
Page  
LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii  
LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv  
CHAPTER 1  
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
1. PURPOSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
2. OUTLINE OF THE MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
CHAPTER 2  
FUNCTIONAL OUTLINE OF CIRCUIT CARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
1. CONTROL CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
2. APPLICATION CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
3. LINE/TRUNK CIRCUIT CARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
CHAPTER 3  
CIRCUIT CARD INSTALLATION CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
1. CIRCUIT CARD MOUNTING SLOTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
2. INSTALLATION CONDITIONS FOR CONTROL CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
2.1  
2.2  
2.3  
2.4  
2.5  
2.6  
PN-CP00/PN-CP00-B/PN-CP00-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
PN-CP01 (FP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
PN-CP02/PN-CP02-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
PN-BS00-A/PN-BS00-B (BS00), PN-BS01-A/PN-BS01-B (BS01) . . . . . . . . . . . . . . . . . . . . . . . 13  
PN-PW00 (EXTPWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
PZ-PW86 (PWR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
3. INSTALLATION CONDITIONS FOR APPLICATION CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . 14  
4. INSTALLATION CONDITIONS FOR LINE/TRUNK CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
CHAPTER 4  
LAMP INDICATIONS AND SWITCH SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
1. PRECAUTION IN HANDLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
2. LAMP INDICATIONS AND SWITCH SETTINGS OF CONTROL CIRCUIT CARDS. . . . . . . . . . . . . . . . 21  
PN-BS00-A/PN-BS00-B (BS00). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
PN-BS01-A (BS01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
PN-BS01-B (BS01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
PN-CP00 (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28  
PN-CP00-B/PN-CP00-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31  
PN-CP03/PN-CP03-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34  
PN-CP01 (FP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37  
PN-CP02/PN-CP02-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39  
PN-PW00 (EXTPWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42  
PZ-PW86 (PWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
PZ-PW86-A (PWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46  
PZ-PW86 (C) (PWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48  
PZ-PW86 (D) (PWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
TABLE OF CONTENTS  
Page i  
Revision 2.2  
Page  
3. LAMP INDICATIONS AND SWITCH SETTINGS OF APPLICATION CIRCUIT CARDS . . . . . . . . . . . . . 52  
PN-AP00-A (AP00) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53  
PN-AP01 (AP01). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
PN-BRTA (BRI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62  
PN-2BRTC (BRI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-1  
PN-CC00 (ETHER) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66  
PN-CC01 (ETHER) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68-1  
PN-CK00 (PLO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69  
PN-24DTA (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72  
PN-24DTA-A (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75  
PN-30DTC/30DTC-A (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78-1  
PN-ME00 (EXTMEM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79  
PN-4RSTB (MFR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84  
PN-4RSTC (CIR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86  
PN-SC00 (CCH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88  
PN-SC01 (DCH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91  
PN-SC02 (ICH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94  
PN-SC03 (ICH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96  
PN-SC03 (CSH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98  
4. LAMP INDICATIONS AND SWITCH SETTINGS OF LINE/TRUNK CIRCUIT CARDS . . . . . . . . . . . . . 100  
PN-2AMPA (AMP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101  
PN-AUCA (AUC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102  
PN-CFTA (CFT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103  
PN-4COTB (COT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104  
PN-4COTG (COT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105  
PN-2DATA (DAT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106  
PN-DK00 (DK). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108  
PN-4DITB (DIT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109  
PN-2DLCB (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110  
PN-2DLCC (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111  
PN-2DLCN (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112  
PN-4DLCA (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113  
PN-4DLCD (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114  
PN-4DLCF (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115  
PN-4DLCM (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116  
PN-4DLCQ (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117  
PN-2DPCB (DPC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118  
PN-2ILCA (ILC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121  
PN-4LCD/4LCD-A (LC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124  
PN-4LCJ (LC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125  
PN-M03 (M03). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126  
PN-2ODTA (ODT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129  
PN-8RSTA (PBR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130  
PN-TNTA (TNT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131  
PN-2CSIA (CSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133  
TABLE OF CONTENTS  
Page ii  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
LIST OF FIGURES  
Figure Title  
Page  
3-1  
3-2  
3-3  
3-4  
3-5  
3-6  
4-1  
4-2  
Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9  
MP/FP Card Mounting Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
MP/FP Card Mounting Slots for Back up MP System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
BS00/BS01 Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Application Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
Line/Trunk Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Static Electricity Precautions (1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Circuit Card Handling Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
ND-45504 (E)  
LIST OF FIGURES  
Page iii  
Revision 2.0  
LIST OF TABLES  
Table  
Title  
Page  
2-1  
2-2  
2-3  
4-1  
4-2  
4-3  
Functional Outline of Control Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
Functional Outline of Application Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
Functional Outline of Line/Trunk Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Table of Control Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
Table of Application Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52  
Table of Line /Trunk Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100  
LIST OF TABLES  
Page iv  
ND-45504 (E)  
Revision 2.0  
CHAPTER 1  
1. PURPOSE  
INTRODUCTION  
For installers and maintenance technicians of the NEAX2000 IVS (PBX), this manual explains the functional  
outline and installation conditions of the circuit cards, and explains the meaning of each indicator lamp (LED)  
and the switch settings on the circuit cards.  
2. OUTLINE OF THE MANUAL  
This manual consists of four chapters. The contents of Chapter 2 through 4 are as outlined below.  
Chapter 2: Functional Outline of Circuit Cards  
This chapter outlines various circuit cards used in the system by means of tables.  
Chapter 3: Circuit Card Accommodating Conditions  
This chapter explains the conditions for installing various circuit cards used in the system.  
Chapter 4: Lamp Indications and Switch Settings  
This chapter explains the meaning of lamp indications and the switch settings of various circuit cards used  
in the system.  
Each switch setting table provided in Chapter 4 has a “CHECK” column. Make necessary entries in the CHECK  
column during and/or after system installation and maintenance. After the result of switch setting has been  
checked, use each table as a reference for subsequent system maintenance and operations.  
ND-45504 (E)  
CHAPTER 1  
Page 1  
Revision 2.0  
This page is for your notes.  
CHAPTER 1  
Page 2  
ND-45504 (E)  
Revision 2.0  
CHAPTER 2  
FUNCTIONAL OUTLINE OF CIRCUIT CARDS  
This chapter explains the functional outline of various circuit cards used in the NEAX2000 IVS. Explanations are  
given in alphabetical order of the circuit card names for each kind (Control, Application, and Line/Trunk) of circuit  
cards.  
1. CONTROL CIRCUIT CARDS  
Table 2-1 shows the functional outline of each control circuit card.  
Table 2-1 Functional Outline of Control Circuit Cards  
FUNCTIONAL  
CARD NAME  
FUNCTIONAL OUTLINE  
NAME  
Bus interface card for PIM0.  
This card functions as a driver/receiver of various signals, adjusts gate delay tim-  
ing and cable delay timing, monitors the I/O Bus and PCM Bus, and controls the  
power supply.  
PN-BS00-A  
/PN-BS00-B  
BS00  
When the system consists of more than one PIM, this card is mounted in PIM0.  
Only one per system is used.  
Bus interface card for PIM1 through PIM7.  
This card functions as a driver/receiver of various signals, adjusts gate delay tim-  
ing and cable delay timing, monitors the I/O Bus and PCM Bus, and controls the  
power supply.  
When the system consists of more than one PIM, one each of this card is mounted  
respectively in PIM1 through PIM7.  
PN-BS01-A  
/PN-BS01-B  
BS01  
MP  
Main Processor card.  
PN-CP00  
/PN-CP00-B  
/PN-CP00-C  
This card is equipped with Memory, TDSW (1024CH × 1024CH), 16-Line CFT,  
PB Sender, Clock, PLO (slave mode 2 ports), RS-232C Ports (2 ports), Modem  
for remote maintenance, and Internal Music-On-Hold tone source.  
One card per system.  
Main Processor card.  
This card is equipped with Memory, TDSW (1024CH × 1024CH), 16-Line CFT,  
PB Sender, PB Receiver, Clock, PLO (slave mode 2 ports), RS-232C Ports (2  
ports) for MAT/Built-in SMDR, Modem for remote maintenance, Internal/Exter-  
nal Music-On-Hold tone source.  
PN-CP03  
/PN-CP03-C  
MP  
One card per system (This card can be used only in 1 or 2 PIM system).  
Firmware Processor card.  
This card is equipped with Line/Trunk Interface and Memory. When the system  
consists of more than one PIM, one each of this card is mounted respectively in  
PIM0, PIM2, PIM4 and PIM6.  
PN-CP01  
FP  
MP  
Main Processor card for Back Up MP System only.  
This card is equipped with Memory, TDSW (1024CH × 1024CH), 16-Line CFT,  
PB Sender, Clock, PLO (slave mode 2 ports), RS-232C Ports (2 ports), Modem  
for remote maintenance, and Music-On-Hold tone source. Two cards per Back up  
MP System.  
PN-CP02  
/PN-CP02-C  
Power Supply card for SN716 Desk Console.  
This card provides –48 V DC power for one SN716 Desk Console, and is mount-  
ed in the LT/AP slot of PIM. Max. 3 PN-PW00 cards per PIM and max. 4 cards  
per 4 PIM.  
PN-PW00  
PW00  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
CHAPTER 2  
Page 3  
Revision 2.2  
Table 2-1 Functional Outline of Control Circuit Cards (Continued)  
FUNCTIONAL  
FUNCTIONAL OUTLINE  
NAME  
CARD NAME  
Main power supply card.  
PZ-PW86/  
PZ-PW86-A  
Input:  
AC100 V/200 V (50 Hz/60 Hz)  
PWR  
PWR  
PWR  
Output: –27 V (8 A), +5 V (8.5 A), CR (30 mA)  
One card per PIM.  
Main power supply card.  
Input:  
Output: –27 V (4.5 A), +5 V (7.5 A), CR (30 mA), +80 V (110 mA)  
One card per PIM.  
AC100 V/200 V (50 Hz/60Hz)  
PZ-PW86(C)  
PZ-PW86(D)  
Main power supply card.  
Input:  
Output: –27 V (4.5 A), +5 V (7.5 A), CR (30 mA), +80 V (110 mA)  
One card per PIM.  
AC100 V/200 V (50 Hz/60 Hz)  
2. APPLICATION CIRCUIT CARDS  
Table 2-2 shows the functional outline of each application circuit card.  
Table 2-2 Functional Outline of Application Circuit Cards  
FUNCTIONAL  
CARD NAME  
FUNCTIONAL OUTLINE  
NAME  
Application Processor card.  
This card is equipped with four RS-232C ports, and is used for SMDR, H/M Print-  
er, PMS functions and MCI.  
PN-AP00-A  
AP00  
One card per system.  
Application Processor card.  
This card is equipped with one RS-232C port and one Ethernet interface port, and  
PN-AP01  
AP01  
is used for OAI function. Also, this card is used to expand authorization code and  
ACD.  
One card per system.  
Basic Rate (2B+D) Interface Trunk card. (S/T Interface)  
This card has one circuit of Basic Rate interface and provides one 2-channel PCM  
digital line.  
PN-BRTA  
BRI  
BRI  
This card is used for BRI trunks from the Telco to the PBX.  
Basic Rate (2B+D) Interface Trunk card.  
This card has two circuits of Basic Rate interface and provides two 2-channel  
PCM digital lines.  
PN-2BRTC  
This card is used for BRI trunks from the Telco to the PBX.  
Memory Expansion card.  
This card is used with PN-AP00-A card for providing expansion memory.  
This card can be equipped with a SRAM card (1MB) as extra SMDR data memo-  
ry.  
PN-ME00  
PN-CC00  
EXTMEM  
ETHER  
Ethernet Control card.  
This card is used with the PN-AP01 card to accommodate the Ethernet, transmit-  
ting/receiving a signal of TCP/IP protocol.  
CHAPTER 2  
Page 4  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
Table 2-2 Functional Outline of Application Circuit Cards (Continued)  
FUNCTIONAL  
FUNCTIONAL OUTLINE  
NAME  
CARD NAME  
Ethernet Control card.  
This card is used with the PN-AP01 card to accommodate the Ethernet, transmit-  
ting/receiving a signal of TCP/IP protocol.  
10 BASE-T twisted pair cable can be connected directly to this card.  
PN-CC01  
ETHER  
PLO  
Phase Locked Oscillator card.  
This card is a phase locked oscillator for providing a synchronized clock signal  
with the network.  
PN-CK00  
This card is used when the PBX is a master office or when the PBX requires two  
clock supply routes and those frequencies differ.  
PN-24DTA  
/PN-24DTA-A  
Digital Trunk Interface (23B+D, 1.5 Mbps) card.  
This card accommodates one 24-channel PCM digital lines.  
DTI  
DTI  
PN-30DTC  
/PN-30DTC-A  
Digital Trunk Interface (2 Mbps) card.  
This card accommodates one 30-channel PCM digital line.  
4-line MF Receiver Trunk card.  
PN-4RSTB  
PN-4RSTC  
PN-SC00  
MFR  
CIR  
This card is used for MF Signaling on Digital DID trunks. A maximum of four  
cards can be provided per one system, including the PN-4RSTC card.  
4-line CALLER ID Receiver Trunk card.  
This card is used for CALLER ID (CLASS SM) on analog trunks. A maximum of  
four cards can be provided per one system, including the PN-4RSTB card.  
Common Channel Handler card.  
This card transmits/receives signals on the common signaling channel of No. 7  
CCIS.  
CCH  
DCH  
D-channel Handler card.  
This card transmits/receives signals on the D channel of ISDN Primary Rate  
(23B+D).  
PN-SC01  
ISDN-channel Handler card.  
This card provides the D channel signaling interface and controls an ILC (Layer 2  
and 3).  
There are 2 types of the ICH card.  
PN-SC02 is the 2-channel ICH card.  
PN-SC03 is the 8-channel ICH card.  
PN-SC02  
/PN-SC03  
ICH  
Zone Transceiver Channel Handler card.  
PN-SC03  
CSH  
This card provides 8 D-channel signaling interface through the PN-2CSIA to the  
Zone Transceiver for the Wireless Communication System.  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 2  
Page 5  
Revision 2.1  
3. LINE/TRUNK CIRCUIT CARDS  
Table 2-3 shows the functional outline of each line/trunk circuit card.  
Table 2-3 Functional Outline of Line/Trunk Circuit Cards  
FUNCTIONAL  
CARD NAME  
FUNCTIONAL OUTLINE  
NAME  
2-line Amplifier Trunk card.  
PN-2AMPA  
AMP  
This card is equipped with the functions of Echo Canceller (EC), Automatic Gain  
Controller (AGC) and Tone Disabler (TD).  
2-line Long-Line circuit card provided with the Power Failure Transfer (PFT)  
function.  
Line resistance in the case of a long-line circuit: Max. 2500 ohms (inclusive of  
the internal resistance of the distant office equipment)  
This card is internally equipped with a –48 V DC On-Board Power Supply.  
This card can also be used as a 2-line Direct Inward Dialling trunk card.  
PN-AUCA  
PN-CFTA  
AUC  
CFT  
Conference Trunk card  
Use of one card: Can control a conference of up to six participants.  
Use of two cards:Can control a conference of up to ten participants.  
4-line Central Office Trunk card (Ground Start/Loop Start trunk) equipped with  
the functions for loop detection, sending/detecting ground on Ring/Tip wire.  
PN-4COTB  
PN-4COTG  
PN-2DATA  
COT  
COT  
DAT  
4-line Central Office Trunk card (Loop Start trunk) equipped with the functions  
for loop detection, receiving/sending the CALLER ID (CLASS SM) signal.  
2-line Digital Announcement Trunk card.  
Duration: Max. 60 seconds.  
Circuit card for External Relay Control/External Key Scan.  
This card is provided with eight circuits, and can provide the above-mentioned  
control functions on a per circuit basis.  
PN-DK00  
PN-4DITB  
DK  
4-line Direct In Dialing Trunk card.  
This card is equipped with the function for loop detection, sending reverse signal  
and PB to DP signal conversion.  
DIT  
This card is internally equipped with –48 V DC On-Board Power supply.  
term  
2-line Digital Line Circuit card for D  
Series E/Series III/DSS Console.  
[–48V Version, 2-wire type, line length: max. 850 m (2789 ft.)]  
This card is equipped with quick diagnostics to detect short line conditions and  
the normality (Synchronous/Asynchronous) of the terminal.  
This card is internally equipped with a –48 V DC On-Board Power Supply.  
term  
PN-2DLCB  
PN-2DLCC  
PN-2DLCN  
DLC  
DLC  
DLC  
2-line Digital Line Circuit card for D  
Series II/SN610 Attendant Console.  
[–48 V Version, 4-wire type, line length: max. 1200 m (3940 ft.)]  
This card is equipped with quick diagnostics to detect short line conditions and  
the normality (Synchronous/Asynchronous) of the terminal.  
This card is internally equipped with –48 V On-Board Power Supply.  
term  
2-line Digital Line Circuit card for D  
Series E/Series III/DSS Console.  
[–48 V Version, 2-wire type, line length: max. 850 m (2789 ft.)]  
This card is equipped with quick diagnostics to detect short line conditions  
and the normality (Synchronous/Asynchronous) of the terminal.  
This card is internally equipped with a –48 V DC On-Board Power Supply.  
CHAPTER 2  
Page 6  
ND-45504 (E)  
Revision 2.0  
Table 2-3 Functional Outline of Line/Trunk Circuit Cards (Continued)  
FUNCTIONAL  
FUNCTIONAL OUTLINE  
NAME  
CARD NAME  
term  
4-line Digital Line Circuit card for D  
Series E/Series III/ElectraPro/DSS Con-  
sole.  
PN-4DLCA  
DLC  
[–27 V Version, 2-wire type, line length: max. 200 m (656 ft.)]  
This card is equipped with quick diagnostics to detect short line conditions and  
the normality (Synchronous/Asynchronous) of the terminal.  
4-line Digital Line Circuit card exclusively used for Dterm Series E/Series III.  
[-27 V Version, 2-wire type, line length: max. 200 m (656 ft.)]  
This card is equippedwith quick diagnostics to detect short line conditions and the  
normality (Synchronous/Asynchronous) of the terminal.  
PN-4DLCD  
PN-4DLCF  
DLC  
DLC  
4-line Digital Line Circuit card for Dterm Series II/SN610 Attendant Console  
[-27 V Version, 4-wire type, line length: max. 300 m (984.3 ft.)].  
This card is equipped with quick diagnostics to detect short line conditions.  
4-line Digital Line Circuit card for Dterm Series E/Series III/ElectraPro/DSS Con-  
sole.  
PN-4DLCM  
PN-4DLCQ  
DLC  
DLC  
[–27 V Version, 2-wire type, line length: max. 200 m (656 ft.)]  
This card is equipped with quick diagnostics to detect short line conditions and  
the normality (Synchronous/Asynchronous) of the terminal.  
4-line Digital Line Circuit card exclusively used for Dterm Series E/Series III.  
[–27 V Version, 2-wire type, line length: max. 200 m (656 ft.)]  
This card is equipped with quick diagnostics to detect short line conditions and  
the normality (Synchronous/Asynchronous) of the terminal.  
2-line Data Port Controller card.  
This card is used for the intra-office or inter-office digital data transmission on  
fixed path connection.  
And this card can accommodate a maximum of two DTE with V.11 (X.21) inter-  
face or V.24/V.28 (RS-232C) interface.  
PN-2DPCB  
PN-2ILCA  
DPC  
ILC  
2-line ISDN Line Circuit card.  
This card provides a physical interface to ISDN Terminals.  
4-line Analog Line Circuit card for single line telephones.  
This card is equipped with the function for controlling Message Waiting Lamp.  
Loop resistance: Max. 600 ohms.  
PN-4LCD  
LC  
LC  
This card is equipped with quick diagnostics to detect short and open line condi-  
tions.  
This card is internally equipped with a +80 V DC-DC Power Supply circuit and  
a relay for momentary open (only in No.3 circuit).  
4-line Analog Line Circuit card for single line telephones.  
This card is equipped with momentary open function.  
This card is equipped with the function for controlling Message Waiting Lamp.  
Loop resistance: Max. 600 ohms.  
PN-4LCD-A  
This card is equipped with quick diagnostics to detect short and open line condi-  
tions.  
This card is internally equipped with a +80 V DC-DC Power Supply circuit.  
ND-45504 (E)  
CHAPTER 2  
Page 7  
Revision 2.0  
Table 2-3 Functional Outline of Line/Trunk Circuit Cards (Continued)  
FUNCTIONAL  
FUNCTIONAL OUTLINE  
NAME  
CARD NAME  
4-line Analog Line Circuit card for single line telephones.  
This card provides 4 circuits with Disconnect Supervision.  
PN-4LCJ  
PN-M03  
LC  
Loop resistance: Max. 600 ohms.  
This card is equipped with quick diagnostics to detect short and open line condi-  
tions.  
V.35 DTE interface card.  
This card is used together with the PN-2DPCB card to provide the V.35 interface.  
M03  
ODT  
2-line OD Trunk card.  
This card can be used as either a 2-wire E&M trunk or a 4-wire E&M trunk, and  
is internally equipped with a –48 V DC On-Board Power Supply.  
Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in  
one card.  
PN-2ODTA  
8-line PB Receiver card.  
This card can be used for a PB station line, DID or tie line.  
PN-8RSTA  
PN-TNTA  
PBR  
TNT  
2-line Tone/Music Source interface card.  
This card is used for BGM or Music on Hold, and is equipped with two interface  
for an external tone/music source.  
2-line Zone Transceiver Interface card.  
The CSI is used to interface with the Wireless Communication System to the  
Zone Transceiver, based on ISDN S-interface.  
Each CSI occupies 7 time slots.  
PN-2CSIA  
CSI  
CHAPTER 2  
Page 8  
ND-45504 (E)  
Revision 2.0  
CHAPTER 3  
CIRCUIT CARD INSTALLATION CONDITIONS  
This chapter explains the conditions for installing various kinds of circuit cards used in the PBX.  
1. CIRCUIT CARD MOUNTING SLOTS  
Figure 3-1 below shows circuit card mounting slots allocated in the PIM based on circuit card type.  
PIM0 - 7  
PWR  
*1  
*2 *3 *4  
BUILT-IN BATTERY  
LT00 - LT15  
AP0 - AP8  
MP  
FP  
BUS  
:
:
:
:
:
:
Line/trunk circuit card mounting slots  
Application circuit card mounting slots  
PN-CP00/PN-CP00-B/PN-CP00-C mounting slot  
PN-CP01 mounting slots  
PN-BS00-A/PN-BS00-B, PN-BS01-A/PN-BS01-B mounting slot  
PZ-PW86 mounting slot  
PWR  
*1 Either line/trunk circuit cards or application circuit cards can be mounted in these slots.  
*2 PN-CP01 or an application circuit card is to be mounted in this slot according to the system  
configuration.  
*3 PN-CP00/PN-CP00-B/PN-CP00-C, PN-CP01 or an application circuit card is to be  
mounted in this slot according to the system configuration.  
*4 PN-BS00-A/PN-BS00-B, PN-BS01-A/PN-BS01-B or an application circuit card is to be  
mounted in this slot according to the system configuration.  
Figure 3-1 Circuit Card Mounting Slots  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
CHAPTER 3  
Page 9  
Revision 2.2  
PIM(H)0  
PWR  
*1  
*2  
*3  
BUILT-IN BATTERY  
LT00 - LT15  
:
:
:
:
:
:
Line/trunk circuit card mounting slots  
Application circuit card mounting slots  
PN-CP02/PN-CP02-C mounting slot  
PN-CP01 mounting slots  
PN-BS00-A/PN-BS00-B, PN-BS01-A/PN-BS01-B mounting slot  
PZ-PW86/PZ-PW86-A/PZ-PW86 (C)/(D) mounting slot  
AP0 - AP8  
MP0, MP1  
FP  
BUS  
PWR  
*1 Either line/trunk circuit cards or application circuit cards can be mounted in these slots.  
*2 Either line/trunk circuit card, PN-CP01 or an application circuit card is to be mounted in this slot  
according to the system configuration.  
*3 PN-BS00-A/PN-BS00-B, PN-BS01-A/PN-BS01-B or an application circuit card is to be mounted in  
this slot according to the system configuration.  
Figure 3-1 Circuit Card Mounting Slots (Continued)  
CHAPTER 3  
Page 10  
Revision 2.2  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
2. INSTALLATION CONDITIONS FOR CONTROL CIRCUIT CARDS  
2.1 PN-CP00/PN-CP00-B/PN-CP00-C (MP)  
Mount the PN-CP00/PN-CP00-B/PN-CP00-C in the MP slot of PIM0.  
2.2 PN-CP01 (FP)  
1. The PN-CP01 is required only if any of the following is true.  
More than one PIM is used.  
A PN-2DLCC is used.  
A PN-AP01 is used.  
OAI, ACD, No. 7 CCIS or ISDN is used.  
2. When the system is equipped with two PIMs, mount one PN-CP01 in the FP slot of PIM0. When the sys-  
tem is equipped with more than two PIMs--depending on the number of additional PIMs used--mount one  
PN-CP01 in the FP slot of PIM0 and one PN-CP01 in the MP/FP slot of PIM2, PIM4 and PIM6.  
PIM3  
PIM2  
PIM1  
PIM0  
PIM7  
PIM6  
PIM5  
PIM4  
F
P
F
P
F
P
M
P
F
P
Figure 3-2 MP/FP Card Mounting Slots  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
CHAPTER 3  
Page 11  
Revision 2.2  
2.3 PN-CP02/PN-CP02-C (MP)  
Mount the PN-CP02/PN-CP02-C in the MP0 and MP1 slot of PIM(H)0.  
This card is used only for Back up MP system.  
PIM3  
PIM7  
PIM6  
PIM5  
PIM4  
F
P
F
P
PIM2  
PIM1  
F
P
M
M
F
P
PIM(H)0  
P
P
1
0
Figure 3-3 MP/FP Card Mounting Slots for Back up MP System  
CHAPTER 3  
Page 12  
Revision 2.2  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
2.4 PN-BS00-A/PN-BS00-B (BS00), PN-BS01-A/PN-BS01-B (BS01)  
1. In a one-PIM system, neither the PN-BS00-A/PN-BS00-B nor the PN-BS01-A/PN-BS01-B is needed.  
2. When the system is equipped with more than one PIM, mount a PN-BS00-A/PN-BS00-B in the BUS slot  
of PIM0 or PIM(H)0.  
3. When the system is equipped with more than one PIM, mount one PN-BS01-A/PN-BS01-B in the BUS  
slot of PIM1 through PIM7, as required.  
B
S
0
1
B
S
0
1
PIM3  
PIM2  
PIM1  
PIM7  
PIM6  
PIM5  
PIM4  
B
S
0
1
B
S
0
1
B
S
0
1
B
S
0
1
B
S
0
0
B
S
0
1
PIM0  
or  
PIM(H)0  
Figure 3-4 BS00/BS01 Card Mounting Slots  
2.5 PN-PW00 (EXTPWR)  
Mount the PW00 card into the LT01-AP8 slot. A maximum of three PW00 cards can be mounted in one frame  
(4PIMs).  
Note: The PW00 card occupies the adjoining left side (smaller number) slot because of its two-stories structure.  
2.6 PZ-PW86 (PWR)  
Mount one PZ-PW86 in the PWR slot of PIM0/PIM(H)0 through PIM7, as required.  
ND-45504 (E)  
CHAPTER 3  
Page 13  
Revision 2.0  
3. INSTALLATION CONDITIONS FOR APPLICATION CIRCUIT CARDS  
1. When the system is equipped with only one PIM:  
An application circuit card can be mounted in the AP0 through AP6, and AP8 slots.  
An application circuit card can not be mounted in the AP6 slot if any of the following is true.  
A PN-2DLCC is used.  
A PN-AP01 is used.  
OAI, ACD, No. 7 CCIS or ISDN is used.  
The PN-CP02s are used.  
2. When the system is equipped with more than one PIM:  
An application circuit card can be mounted in the AP0 through AP5 slots of PIM0/PIM(D)0.  
An application circuit card can be mounted in the AP0 through AP6 slots of PIM2, 4 and 6.  
An application circuit card can be mounted in the AP0 through AP7 slots of PIM1, 3, 5 and 7.  
If the system is equipped with CP02s, the AP5 and AP6 slot of PIM(H)0 cannot be used for an appli-  
cation circuit card.  
Note 1: The application circuit card (PN-24DTA/PN-24DTA-A/PN-30DTC/PN-30DTC-A) cannot be mounted  
in either the AP7 or the AP8 slot since neither of these slots have a connection to the MDF through the  
Back Wiring Board.  
Note 2: The application circuit card (PN-24DTA/PN-24DTA-A/PN-30DTC/PN-30DTC-A [DT10, DT11] which  
receives a clock signal must be mounted in the AP0 through AP5 slots of PIM0/PIM(H)0.  
Note 3: The application circuit card (PN-CK00) must be mounted in the AP0 through AP6 slots of PIM0/  
PIM(H)0.  
Note 4: The application circuit card (PN-CC00/PN-CC01) can be mounted in any one of the LT slots or the AP  
slots.  
PN-CC00 card needs two LT/AP slots per one card.  
Note 5: The application circuit card (PN-CC00/PN-CC01) should be mounted in a LT/AP slot that adjoins an  
AP slot for the PN-AP01 card because the cable (48-TW0.3 CONN CA) is connected between the PN-  
CC00/PN-CC01 card and the PN-AP01 card.  
CHAPTER 3  
Page 14  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
LT SLOTS (00-09)  
PIM0-7  
PWR  
*
BUILT-IN BATTERY  
Line/trunk circuit cards can also be mounted in AP0 - AP5 slots.  
LT SLOTS (00-09)  
PIMH (0)  
PWR  
*
BUILT-IN BATTERY  
Line/trunk circuit cards can also be mounted in AP0 - AP5 slots.  
Figure 3-5 Application Circuit Card Mounting Slots  
ND-45504 (E)  
CHAPTER 3  
Page 15  
Revision 2.0  
4. INSTALLATION CONDITIONS FOR LINE/TRUNK CIRCUIT CARDS  
Mount the line/trunk circuit cards in the LT00 through LT15 slots of PIM0/PIM(H)0 through PIM7.  
PIM0-7  
PWR  
*
BUILT-IN BATTERY  
Application circuit cards can also be mounted in the LT10 through LT15 slots.  
PIM(H)0  
PWR  
*
BUILT-IN BATTERY  
Application circuit cards can also be mounted in the LT10 through LT15 slots.  
Figure 3-6 Line/Trunk Circuit Card Mounting Slots  
CHAPTER 3  
Page 16  
ND-45504 (E)  
Revision 2.0  
CHAPTER 4  
LAMP INDICATIONS AND SWITCH SETTINGS  
This chapter explains various circuit cards used in the PBX with respect to the following items. Explanations  
are given in the alphabetical order of the circuit card names within each circuit card category (Control, Appli-  
cation, and Line/Trunk).  
1. Locations of Lamps, Switches, and Connectors  
The locations of lamps, switches, and connectors of each circuit card are shown by a face layout.  
2. Lamp Indications  
The name, color, and functions of each indicator lamp equipped on each circuit card are shown and de-  
scribed in a table.  
3. Switch Settings  
The name, settings, and functions of each switch equipped on each circuit card are shown and described in  
a table.  
Each switch setting table has a “CHECK” column. Make necessary entries in the CHECK column during and/  
or after system installation and maintenance, and use each table as a reference for subsequent system mainte-  
nance and operations.  
ND-45504 (E)  
CHAPTER 4  
Page 17  
Revision 2.0  
1. PRECAUTION IN HANDLING  
When handling a circuit card, the installer must wear a grounded wrist strap to protect the circuit card from static  
electricity.  
• WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD  
PBX  
FRAME GROUND SCREW  
CONNECT THE GROUND WIRE TO THE  
FRAME EARTH OF THE EQUIPMENT.  
WRIST STRAP  
NEVER TOUCH THE COMPONENTS OR  
• WHEN HOLDING A CIRCUIT CARD  
SOLDERED SURFACE WITH BARE HANDS.  
CARD FRONT  
Figure 4-1 Static Electricity Precautions (1 of 2)  
CHAPTER 4  
Page 18  
ND-45504 (E)  
Revision 2.0  
• WHEN SETTING SWITCHES ON A CIRCUIT CARD  
CIRCUIT  
CARD  
WEAR A WRIST STRAP AND PERFORM  
THE WORK STANDING ON A GROUNDED  
CONDUCTIVE WORK SURFACE.  
• WHEN CARRYING A CIRCUIT CARD  
CIRCUIT  
CARD  
CONDUCTIVE  
POLYETHYLENE  
BAG  
WHEN CARRYING A CIRCUIT  
CARD AROUND, KEEP THE  
CARD IN THE CONDUCTIVE  
POLYETHYLENE BAG.  
Figure 4-1 Static Electricity Precautions (2 of 2)  
ND-45504 (E)  
CHAPTER 4  
Page 19  
Revision 2.0  
CAUTION  
The installer must hold the edge of circuit card, when plugging or unplugging the circuit card. If you touch  
another area, you may be exposed to hazardous voltages.  
PBX  
NEVER TOUCH THE COMPONENTS  
OR SOLDERED SURFACE WITH  
BASE HANDS.  
CARD FRONT  
Figure 4-2 Circuit Card Handling Precautions  
CHAPTER 4  
Page 20  
ND-45504 (E)  
Revision 2.0  
2. LAMP INDICATIONS AND SWITCH SETTINGS OF CONTROL CIRCUIT CARDS  
Table 4-1 below shows the control circuit cards to be explained in this section.  
Table 4-1 Table of Control Circuit Cards  
EXTRACTION/INSERTION  
EXISTENCE OF  
LAMPS  
X: PROVIDED  
EXISTENCE OF  
SWITCHES  
X: PROVIDED  
NAME  
(FUNCTIONAL  
NAME)  
WITH POWER ON  
X: ALLOWED  
: ALLOWED AFTER MB*  
—: NOT ALLOWED  
REFERENCE  
PAGE  
—: NOT PROVIDED —: NOT PROVIDED  
PN-BS00-A/  
PN-BS00-B (BS00)  
X
22  
PN-BS01-A (BS01)  
PN-BS01-B (BS01)  
PN-CP00 (MP)  
X
X
X
X
24  
26  
28  
PN-CP00-B  
/PN-CP00-C (MP)  
X
X
31  
PN-CP03  
/PN-CP03-C (MP)  
X
X
X
X
X
X
34  
37  
39  
PN-CP01 (FP)  
PN-CP02  
/PN-CP02-C (MP)  
PN-PW00  
(EXTPWR)  
X
X
42  
PZ-PW86 (PWR)  
X
X
X
X
X
X
44  
46  
48  
PZ-PW86-A (PWR)  
PZ-PW86(C) (PWR)  
PZ-PW86(D)  
(PWR)  
X
X
50  
* MB = Make Busy  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
CHAPTER 4  
Page 21  
Revision 2.2  
PN-BS00-A/PN-BS00-B (BS00)  
PN-BS00-A/PN-BS00-B (BS00)  
1. Locations of Lamps, Switches, and Connectors  
MB  
CN2  
CN1  
PN-BS00-A/PN-BS00-B (BS00) Card  
2. Lamp Indications  
This card has no indicator lamps.  
CHAPTER 4  
ND-45504 (E)  
Page 22  
Revision 2.0  
PN-BS00-A/PN-BS00-B (BS00)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
For make-busy  
CHECK  
MB (Toggle SW)  
UP  
ON  
For normal operation  
DOWN  
Note  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.  
ND-45504 (E)  
CHAPTER 4  
Page 23  
Revision 2.0  
PN-BS01-A (BS01)  
PN-BS01-A (BS01)  
1. Locations of Lamps, Switches, and Connectors  
MB  
CN2  
SW13  
CN1  
PN-BS01-A (BS01) Card  
2. Lamp Indications  
This card has no indicator lamps.  
CHAPTER 4  
ND-45504 (E)  
Page 24  
Revision 2.0  
PN-BS01-A (BS01)  
CHECK  
(3) Switch Settings  
Switch Settings  
SWITCH  
SETTING  
NUMBER POSITION  
SWITCH NAME  
FUNCTION  
MB (Toggle SW)  
UP  
For make-busy  
ON  
For normal operation  
DOWN  
Note  
SW13 (Dip SW)  
ON  
Set SW13 according to the mounting location of this  
card.  
1, 5  
OFF  
ON  
1 2 3 4 5 6 7 8  
ON  
2, 6  
SWITCH  
OFF  
SW13 SW13 SW13 SW13  
No.  
MOUNTING  
LOCATION  
-1, 5  
-2, 6  
-3,7  
-4, 8  
ON  
3, 7  
PIM1  
ON  
OFF  
OFF  
OFF  
OFF OFF  
OFF  
OFF  
OFF  
ON  
OFF  
PIM2, PIM3  
PIM4, PIM5  
PIM6, PIM7  
ON  
OFF  
OFF  
ON  
ON  
4, 8  
OFF OFF  
OFF  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.  
ND-45504 (E)  
CHAPTER 4  
Page 25  
Revision 2.0  
PN-BS01-B (BS01)  
PN-BS01-B (BS01)  
1. Locations of Lamps, Switches, and Connectors  
SW0  
MB  
CN2  
CN1  
PN-BS01-B (BS01) Card  
2. Lamp Indications  
This card has no indicator lamps.  
CHAPTER 4  
ND-45504 (E)  
Page 26  
Revision 2.0  
PN-BS01-B (BS01)  
CHECK  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
SW0 (Rotary SW)  
Set this rotary switch to match the location in which this circuit  
card is to be mounted.  
For mounting this card in PIM1  
For mounting this card in PIM2, 3  
For mounting this card in PIM4, 5  
For mounting this card in PIM6, 7  
Not used  
0
1
2
3
0 - 3  
4 - F  
Note 1  
MB (Toggle SW)  
For make-busy  
UP  
ON  
For normal operation  
DOWN  
Note 2  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the desired switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
CHAPTER 4  
Page 27  
Revision 2.0  
PN-CP00 (MP)  
PN-CP00 (MP)  
1. Locations of Lamps, Switches, and Connectors  
SW3  
RUN  
SW1  
SW2  
CLKIN  
JP0  
RS  
PN-CP00 (MP) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
Green  
Green  
Flashes at 120 IPM while the circuit card is operating normally.  
Lights while receiving clock signals to the PLO oscillator.  
CLKIN  
CHAPTER 4  
ND-45504 (E)  
Page 28  
Revision 2.0  
PN-CP00 (MP)  
CHECK  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
SW3 (Rotary SW)  
On Line (Call processing is in progress)  
0
2
Off Line (Call processing is stopped)  
• I/O port: Depending on  
CM40 YY=08  
0
Off Line (Call processing is stopped)  
• I/O port: 1200 bps (Fixed)  
3
0 ~ F  
B
C
For clearing the office data  
For setting the resident system program  
Note  
1, 4 ~ 9  
A, D ~ F  
Not used  
SW1 (Push SW)  
For initializing the CPU  
KF Mode  
SW2 (Piano Key SW)  
ON  
1
OFF  
MF/PF Mode.  
OFF  
Selection of PLO (Phase Locked Oscillator)  
• When using the internal PLO of MP card:  
4
3
2
1
SWITCH NUMBER  
FUNCTION  
1.5 MHz clock  
2
3
ON  
OFF  
OFF  
[For PN-24DTA/PN-24DTA-A]  
2, 3  
192 kHz clock  
[For PN-BRTA]  
ON  
OFF  
2 MHz clock  
OFF  
ON  
ON  
ON  
[For PN-30DTC/PN-30DTC-A/  
PN-2BRTC]  
Not used  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 29  
Revision 2.1  
PN-CP00 (MP)  
Switch Settings (Continued)  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SW2 (Piano Key SW)  
• When using the PLO card (PN-CK00):  
SW2-2  
OFF  
SW2-3  
ON  
OFF  
2, 3  
4
3
2
1
• When not using the internal PLO and the PLO card:  
SW2-2  
OFF  
SW2-3  
OFF  
ON  
4
Not used  
OFF  
JP0 (Jumper pin)  
LEFT  
RIGHT  
UP  
For factory testing  
Front  
For normal operation  
JP2 (Jumper pin)  
For normal operation  
Memory backup connected  
For factory test only  
Disconnect battery  
DOWN  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note: Set the groove on the switch knob to the desired switch position.  
CAUTION  
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its  
mounting slot.  
CHAPTER 4  
Page 30  
ND-45504 (E)  
Revision 2.0  
PN-CP00-B/PN-CP00-C (MP)  
PN-CP00-B/PN-CP00-C (MP)  
1. Locations of Lamps, Switches, and Connectors  
SW3  
RUN  
SW1  
SW2  
CLKIN  
RS  
[CP00-B] Note JP0  
[CP00-C] Note  
JP0  
Note: Location of JP0 is different between CP00-B and CP00-C.  
PN-CP00-B/PN-CP00-C (MP) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
Green  
Green  
Flashes at 120 IPM while the circuit card is operating normally.  
Lights while receiving clock signals to the PLO oscillator.  
CLKIN  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
CHAPTER 4  
Page 31  
Revision 2.2  
PN-CP00-B/PN-CP00-C (MP)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SW3 (Rotary SW)  
0
2
On Line (Call processing is in progress)  
Off Line (Call processing is stopped)  
• I/O port: Depending on CM40 YY=08  
0
Off Line (Call processing is stopped)  
• I/O port: 1200 bps (Fixed)  
3
0 ~ F  
B
C
For clearing the office data  
Note  
For setting the resident system program  
1, 4 ~ 9  
A, D ~ F  
Not used  
SW1 (Push SW)  
For initializing the CPU  
KF Mode  
SW2 (Piano Key SW)  
ON  
1
OFF  
MF/PF Mode  
OFF  
Selection of PLO (Phase Locked Oscillator)  
• When using the internal PLO of MP card:  
8
7
6
5
4
3
2
1
SWITCH NUMBER  
FUNCTION  
1.5 MHz clock  
2
3
OFF  
OFF  
[For PN-24DTA/PN-24DTA-A]  
2, 3  
192 kHz clock  
[For PN-BRTA]  
ON  
OFF  
2 MHz clock  
ON  
OFF  
ON  
ON  
ON  
[For PN-30DTC/PN-30DTC-A  
/PN-2BRTC]  
Not used  
CHAPTER 4  
Page 32  
Revision 2.2  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
PN-CP00-B/PN-CP00-C (MP)  
Switch Settings (Continued)  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SW2 (Piano Key SW)  
• When using the PLO card (PN-CK00):  
SW2-2  
OFF  
SW2-3  
ON  
OFF  
2, 3  
8
7
6
5
4
3
2
1
• When not using the internal PLO and the PLO card:  
SW2-2  
OFF  
SW2-3  
OFF  
4 ~ 8  
Not used  
OFF  
ON  
JP0 (Jumper pin)  
For normal operation  
Memory backup connected  
UP  
For factory testing  
(Disconnect battery for memory backup.)  
DOWN  
Front  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION column  
indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
setting of the switch varies with the system concerned.  
, the  
Note: Set the groove on the switch to the desired switch position.  
CAUTION  
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its  
mounting slot.  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
CHAPTER 4  
Page 33  
Revision 2.2  
PN-CP03/PN-CP03-C (MP)  
PN-CP03/PN-CP03-C (MP)  
1. Locations of Lamps, Switches, and Connectors  
SW3  
RUN  
SW1  
SW2  
JACK  
CLK  
JP0  
JP1  
VR  
RS1  
RS0  
PN-CP03/PN-CP03-C (MP) Card  
Lamp Indications  
2. Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
Green  
Green  
Flashes at 120 IPM while the circuit card is operating normally.  
Lights while receiving clock signals to the PLO oscillator.  
CLKIN  
CHAPTER 4  
Page 34  
Revision 2.2  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
PN-CP03/PN-CP03-C (MP)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
On Line (Call processing is in progress)  
CHECK  
SW3 (Rotary SW)  
0
2
Off Line (Call processing is stopped)  
• I/O port: Depending on CM40 YY=08  
Off Line (Call processing is stopped)  
• I/O port: 1200 bps (Fixed)  
3
0 ~ F  
Note  
B
C
For clearing the office data  
For setting the resident system program  
1, 4 ~ 9  
A, D ~ F  
Not used  
SW1 (Push SW)  
For initializing the CPU  
KF Mode  
SW2 (Piano Key SW)  
ON  
1
OFF  
MF/PF Mode  
OFF  
Selection of PLO (Phase Locked Oscillator)  
When using the internal PLO of MP card:  
4
3
2
1
SWITCH NUMBER  
FUNCTION  
1.5 MHz clock  
[For PN-24DTA/PN-24DTA-A]  
192 kHz clock  
2
3
OFF  
OFF  
ON  
2, 3  
ON  
OFF  
[For PN-BRTA]  
2 MHz clock  
OFF  
ON  
ON  
ON  
[For PN-30DTC/PN-30DTC-A  
/PN-2BRTC]  
Not used  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
CHAPTER 4  
Page 35  
Revision 2.2  
PN-CP03/PN-CP03-C (MP)  
Switch Settings (Continued)  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SW2 (Piano Key SW)  
• When using the PLO card (PN-CK00):  
SW2-2  
OFF  
SW2-3  
ON  
OFF  
2, 3  
• When not using the internal PLO and the PLO card:  
SW2-2  
OFF  
SW2-3  
OFF  
4
3
2
1
ON  
When using RS1 port for built-in MODEM  
When using RS1 port for RS-232C.  
4
ON  
OFF  
VR (Rotary SW)  
Variable Resister for External Hold Tone  
Source  
(0 - 20 K: Clockwise)  
20  
0
JP0 (Jumper pin)  
For normal operation  
UP  
DOWN  
UP  
Memory backup connected  
For factory testing  
(Disconnect battery for memory backup.)  
Front  
JP1 (Jumper pin)  
For normal operation  
DOWN  
For using External Tone Source  
Front  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note: Set the groove on the switch knob to the desired switch position.  
CAUTION  
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its  
mounting slot. When the CP03/CP03-C is plugged in and power is on, do not move Jumper JP1.  
CHAPTER 4  
Page 36  
Revision 2.2  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
PN-CP01 (FP)  
PN-CP01 (FP)  
1. Locations of Lamps, Switches, and Connectors  
SW1  
RUN  
MB  
PN-CP01 (FP) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
Green  
FUNCTION  
RUN  
Flashes at 120 IPM while the circuit card is operating normally.  
ND-45504 (E)  
CHAPTER 4  
Page 37  
Revision 2.0  
PN-CP01 (FP)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SW1 (Rotary SW)  
Set this rotary switch to match the location in which this cir-  
cuit card is to be mounted.  
0
1
2
3
For mounting this card in PIM0  
For mounting this card in PIM2  
For mounting this card in PIM4  
For mounting this card in PIM6  
Not used  
0 – 3  
4 – F  
Note 1  
MB (Toggle SW)  
UP  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the desired switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
Note 3:  
The PN-CP01 is required only if any of the following is true:  
More than one PIM is used.  
A PN-2DLCC is used.  
A PN-AP01 is used.  
OAI, ACD, No. 7 CCIS, or ISDN is used.  
CHAPTER 4  
Page 38  
ND-45504 (E)  
Revision 2.0  
PN-CP02/PN-CP02-C (MP)  
PN-CP02/PN-CP02-C (MP)  
1. Locations of Lamps, Switches, and Connectors  
SW3  
RUN  
SW1  
SW2  
CLKIN  
STBY  
[CP02] Note  
JP0  
SW4  
MT  
RS  
[CP02-C] Note JP0  
Note: Location of JP0 is different between CP02 and CP02-C.  
PN-CP02/PN-CP02-C (MP) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Flashes at 120 IPM while the circuit card is active status and operating normally.  
• Flashes at 30 IPM or 15 IPM while the circuit card is stand by status.  
Normally operating: 30 IPM (1 sec - ON, 1 sec - OFF)  
RUN  
Green  
Copying office data: 15 IPM (3 sec - ON, 1 sec - OFF)  
CLKIN  
STBY  
Green  
Red  
Lights while receiving clock signals to the PLO oscillator.  
Lights when the circuit card is in the standby mode.  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
CHAPTER 4  
Page 39  
Revision 2.2  
PN-CP02/PN-CP02-C (MP)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SW3 (Rotary SW)  
On Line (Call processing is in progress)  
0
2
Off Line (Call processing is stopped)  
• I/O port: Depending on CM40 YY=08  
0
Off Line (Call processing is stopped)  
• I/O port: 1200 bps (Fixed)  
3
0 ~ F  
Note 2  
Note 1  
B
C
For clearing the office data  
For setting the resident system program  
1, 4 ~ 9  
A, D ~ F  
Not used  
SW1 (Push SW)  
For initializing the CPU  
KF Mode  
SW2 (Piano Key SW)  
ON  
1
OFF  
MF/PF Mode  
OFF  
Selection of PLO (Phase Locked Oscillator)  
• When using the internal PLO of MP card:  
8
7
6
5
4
3
2
1
SWITCH  
NUMBER  
FUNCTION  
2
3
1.5 MHz clock  
[For PN-24DTA/PN-24DTA-A]  
OFF  
OFF  
2, 3  
192 kHz clock  
[For PN-BRTA]  
ON  
OFF  
ON  
2 MHz clock  
OFF  
ON  
ON  
ON  
[For PN-30DTC/PN-30DTC-A/PN-  
2BRTC]  
Not used  
CHAPTER 4  
Page 40  
Revision 2.2  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
PN-CP02/PN-CP02-C (MP)  
Switch Settings (Continued)  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SW2 (Piano Key SW)  
• When using the PLO card (PN-CK00):  
SW2-2  
OFF  
SW2-3  
ON  
OFF  
2, 3  
8
7
6
5
4
3
2
1
• When not using the internal PLO and the PLO card:  
SW2-2  
OFF  
SW2-3  
OFF  
4 ~ 7  
Not used  
OFF  
ON  
ON  
Allowed to use MAT  
8
Note 3  
For normal operation  
(Not allowed to use MAT)  
OFF  
JP0 (Jumper pin)  
For normal operation  
Memory backup connected  
UP  
Front  
For factory test only  
(Disconnect battery for memory backup.)  
DOWN  
UP  
SW4 (Toggle SW)  
For make-busy  
ON  
For normal operation  
DOWN  
Note 4  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch to the desired switch position.  
On the stand by status circuit card, the SW3 can be set to only “0” or “B”. Do not set to the other  
position (1-9, A, C-F).  
Note 3:  
Note 4:  
MP0 and MP1 must not set to “ON” at the same time.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
Addendum-002  
OCTOBER, 1998  
CHAPTER 4  
Page 41  
Revision 2.2  
PN-PW00 (EXTPWR)  
PN-PW00 (EXTPWR)  
1. Locations of Lamps, Switches and Connectors  
RUN  
MB  
CONN  
PN-PW00 (EXTPWR) Card  
Lamp Indications  
2. Lamp Indications  
LAMP NAME  
COLOR  
Green  
FUNCTION  
RUN  
Remains lit while –48 V power is being supplied  
CHAPTER 4  
Page 42  
ND-45504 (E)  
Revision 2.0  
PN-PW00 (EXTPWR)  
CHECK  
(3) Switch Setting  
Switch Settings  
SWITCH  
NAME  
SWITCH  
SETTING  
FUNCTION  
NUMBER  
POSITION  
MB (Toggle SW)  
For make-busy (–48 V power off)  
UP  
ON  
For normal operation (–48 V power on)  
Note  
DOWN  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.  
ND-45504 (E)  
CHAPTER 4  
Page 43  
Revision 2.0  
PZ-PW86 (PWR)  
PZ-PW86 (PWR)  
1. Locations of Lamps, Switches, and Connectors  
SW102  
MJ  
MJ  
MN  
ON  
MN  
ON  
ON  
1
2
GND  
FG  
GND  
–27V  
FG  
–27V  
ON  
OFF  
100/120  
240  
SIDE VIEW  
FRONT VIEW  
PZ-PW86 (PWR) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
MJ  
MN  
ON  
Red  
Lights upon occurrence of a major trouble  
Lights upon occurrence of a minor trouble  
Yellow  
Green  
Remains lit while the operating power is being supplied  
CHAPTER 4  
ND-45504 (E)  
Page 44  
Revision 2.0  
PZ-PW86 (PWR)  
CHECK  
(3) Switch Settings  
Switch Settings  
SETTING  
SWITCH  
SWITCH NAME  
FUNCTION  
NUMBER  
POSITION  
Set to ON.  
1
ON  
ON  
Standard setting (for equalize charging)  
Not used  
1
2
ON  
OFF  
ON  
2
SW  
For turning AC source power on  
For turning AC source power off  
AC INPUT: 90 V - 138 V  
AC INPUT: 180 V - 276 V  
I (ON)  
O (OFF)  
OFF  
100/120  
240  
UP  
DOWN  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
CAUTION  
• When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from  
its mounting slot.  
• Set the appropriate voltage by using the AC voltage select switch (slide switch) before powering on.  
ND-45504 (E)  
CHAPTER 4  
Page 45  
Revision 2.0  
PZ-PW86-A (PWR)  
PZ-PW86-A (PWR)  
1. Locations of Lamps, Switches, and Connectors  
SW102  
MJ  
SW102  
MJ  
MN  
ON  
MN  
ON  
ON  
1
2
GND  
FG  
GND  
–27V  
FG  
–27V  
ON  
OFF  
100/120  
240  
SIDE VIEW  
FRONT VIEW  
PZ-PW86-A (PWR) Card  
Lamp Indications  
2. Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
MJ  
MN  
ON  
Red  
Lights upon occurrence of a major trouble  
Lights upon occurrence of a minor trouble  
Yellow  
Green  
Remains lit while the operating power is being supplied  
CHAPTER 4  
ND-45504 (E)  
Page 46  
Revision 2.0  
PZ-PW86-A (PWR)  
CHECK  
(3) Switch Settings  
Switch Settings  
SETTING  
SWITCH  
SWITCH NAME  
FUNCTION  
NUMBER  
POSITION  
SW102  
To start each PIM on battery power, when AC  
power is not provided (Switch “SW” must be  
ON).  
PRESS  
MOMENTARILY  
1
2
Set to ON.  
ON  
ON  
ON  
1
2
For float charging  
Standard setting for equalize charging (Set to  
equalize for Gel cell or no battery.)  
OFF  
ON  
SW  
For turning AC source power on  
For turning AC source power off  
AC INPUT: 90 V - 138 V  
I (ON)  
O (OFF)  
OFF  
100/120  
UP  
DOWN  
AC INPUT: 180 V - 276 V  
240  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
CAUTION  
• When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from  
its mounting slot.  
• Set the appropriate voltage by using the AC voltage select switch (slide switch) before powering on.  
ND-45504 (E)  
CHAPTER 4  
Page 47  
Revision 2.0  
PZ-PW86 (C) (PWR)  
PZ-PW86 (C) (PWR)  
1. Locations of Lamps, Switches, and Connectors  
BATTERY  
START  
SW102  
MJ  
MN  
ON  
ON  
1
2
MODE  
ON  
GND  
FG  
2
1
–27V  
SW301  
SIG  
SW1  
BATT2  
ON  
OFF  
BATT1  
100/120VAC  
240VAC  
AC INPUT  
SIDE VIEW  
FRONT VIEW  
PZ-PW86(C) (PWR) Card  
Lamp Indications  
2. Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
MJ  
MN  
ON  
Red  
Lights upon occurrence of a major trouble  
Lights upon occurrence of a minor trouble  
Orange  
Green  
Remains lit while the operating power is being supplied  
CHAPTER 4  
ND-45504 (E)  
Page 48  
Revision 2.0  
PZ-PW86 (C) (PWR)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
Always set to OFF  
CHECK  
MODE  
1
OFF  
ON  
Float charging, for sealed batteries (Normal  
Setting).  
OPTION: Periodic Equalize charging of  
external vented batteries.  
ON  
1
2
2
Flaot charging, for vented batteries only.  
OFF  
ON  
SW1  
For turning AC power and the battery on  
For turning AC power and the battery off  
ON (I)  
OFF  
OFF (O)  
AC INPUT: 90 V - 138 V  
AC INPUT: 180 V - 264 V  
100/120 VAC  
UP  
DOWN  
240 VAC  
SW102  
To start each PIM on battery power, when  
AC power is not provided (switch “SW”  
must be ON)  
PRESS  
MOMENTARILY  
SW301  
ON  
OFF  
ON  
CR Voltage: 75 Vrms  
CR Voltage: 90 Vrms  
Frequency: 20 Hz  
1
2
20Hz  
25Hz  
2
1
ON  
OFF  
90V  
Frequency: 25 Hz  
75V  
OFF  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
ND-45504 (E)  
CHAPTER 4  
Page 49  
Revision 2.0  
PZ-PW86 (D) (PWR)  
PZ-PW86 (D) (PWR)  
1. Locations of Lamps, Switches, and Connectors  
MJ  
MN  
ON  
ON  
1
2
MODE  
BATTERY  
START  
SW102  
ON  
2
1
GND  
FG  
–27V  
SW301  
SIG  
(CN103)  
SIG  
(CN103)  
BATT2  
BATT1  
100/120VAC  
240VAC  
SW1  
ON  
OFF  
AC INPUT  
SIDE VIEW  
FRONT VIEW  
PZ-PW86(D) (PWR) Card  
Lamp Indications  
2. Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
MJ  
MN  
ON  
Red  
Lights upon occurrence of a major trouble  
Lights upon occurrence of a minor trouble  
Orange  
Green  
Remains lit while the operating power is being supplied  
CHAPTER 4  
ND-45504 (E)  
Page 50  
Revision 2.0  
PZ-PW86 (D) (PWR)  
(3) Switch Settings  
Switch Settings  
SETTING  
SWITCH  
NUMBER  
SWITCH NAME  
FUNCTION  
CHECK  
POSITION  
MODE  
1
Always set to OFF  
OFF  
Float charging, for sealed batteries (Normal  
Setting).  
OPTION: Periodic Equalize charging of  
external vented batteries.  
ON  
ON  
1
2
2
Flaot charging, for vented batteries only.  
OFF  
ON  
SW1  
For turning AC power and the battery on  
For turning AC power and the battery off  
ON (I)  
OFF  
OFF (O)  
AC INPUT: 90 V - 138 V  
AC INPUT: 180 V - 264 V  
100/120 VAC  
UP  
DOWN  
240 VAC  
SW102  
To start each PIM on battery power, when  
AC power is not provided (switch “SW”  
must be ON)  
PRESS  
MOMENTARILY  
SW301  
ON  
OFF  
ON  
CR Voltage: 75 Vrms  
CR Voltage: 90 Vrms  
Frequency: 20 Hz  
1
2
20Hz  
25Hz  
2
1
ON  
OFF  
90V  
Frequency: 25 Hz  
75V  
OFF  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
ND-45504 (E)  
CHAPTER 4  
Page 51  
Revision 2.0  
3. LAMP INDICATIONS AND SWITCH SETTINGS OF APPLICATION CIRCUIT CARDS  
Table 4-2 below shows the application circuit cards to be explained in this section.  
Table 4-2 Table of Application Circuit Cards  
EXTRACTION/INSER-  
EXISTENCE OF  
LAMPS  
X: PROVIDED  
EXISTENCE OF  
SWITCHES  
X: PROVIDED  
NAME  
(FUNCTIONAL  
NAME)  
TION WITH POWER ON  
X: ALLOWED  
REFERENCE  
PAGE  
: ALLOWED AFTER MB*  
—: NOT PROVIDED —: NOT PROVIDED  
—: NOT ALLOWED  
PN-AP00-A (AP00)  
PN-AP01 (AP01)  
PN-BRTA (BRI)  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
53  
59  
62  
PN-2BRTC (BRI)  
PN-CC00 (ETHER)  
PN-CC01 (ETHER)  
PN-CK00 (PLO)  
65-1  
66  
68-1  
69  
PN-24DTA (DTI)  
PN-24DTA-A (DTI)  
72  
75  
PN-30DTC/30DTC-A  
(DTI)  
X
X
78-1  
PN-ME00 (EXTMEM)  
PN-4RSTB (MFR)  
PN-4RSTC (CIR)  
PN-SC00 (CCH)  
PN-SC01 (DCH)  
PN-SC02 (ICH)  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
79  
84  
86  
88  
91  
94  
96  
98  
PN-SC03 (ICH)  
PN-SC03 (CSH)  
* MB=Make Busy  
CHAPTER 4  
Page 52  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
PN-AP00-A (AP00)  
PN-AP00-A (AP00)  
1. Locations of Lamp, Switches, and Connectors  
SENSE  
RUN  
MB  
J16  
SW1  
WE  
L3  
L2  
L1  
L0  
RS3  
RS2  
RS1  
RS0  
SW0  
PN-AP00-A (AP00) Card  
ND-45504 (E)  
CHAPTER 4  
Page 53  
Revision 2.0  
PN-AP00-A (AP00)  
(2) Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
WE  
Green  
Red  
Flashes at 120 IPM while this card is operating normally.  
Not used.  
Second data setting value for the first data 250 of CM D001  
L0 - L3  
0
1 (port 0) - 3 (port 2)  
Indication of the transmitting status of Indication of the status of CTS signal on  
port 0 port 0 - 2  
Indication of the transmitting status of Indication of the status of DCD signal  
port 1 on port 0 - 2  
Indication of the transmitting status of Indication of the status of TXD signal  
port 2 on port 0 - 2  
Indication of the transmitting status of Indication of the status of RXD signal  
port 3 on port 0 - 2  
L3  
L2  
L1  
L0  
Green  
CHAPTER 4  
Page 54  
ND-45504 (E)  
Revision 2.0  
PN-AP00-A (AP00)  
CHECK  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
SENSE  
(Rotary SW)  
Set the switch to match the AP Number (04 - 15) to be set by  
CM05.  
4 - F  
04 05 06 07 08 09 10 11 12 13 14 15  
AP NO.  
SW NO.  
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 - 3  
Not used  
MB (Toggle SW)  
UP  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
SW1 (Piano Key SW)  
For normal operation  
Not used  
ON  
1
2
OFF  
OFF  
For normal operation  
ON  
4
3
2
1
OFF  
For AP data clearing by CMD100/CMD101  
For normal operation  
ON  
3
4
OFF  
For AP data clearing by CMD100/CMD101  
Always set to OFF  
ON  
OFF  
J16 (Jumper pin)  
Memory backup ON  
RIGHT  
Memory backup OFF  
LEFT  
Front  
ND-45504 (E)  
CHAPTER 4  
Page 55  
Revision 2.0  
PN-AP00-A (AP00)  
Switch Settings (Continued)  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SW0 (Dip SW)  
Enables the receive clock from the DCE (Mo-  
dem) side when the No. 0 Port is synchronous.  
(Clock is received at the RXC terminal.)  
ON  
OFF  
ON  
ON  
1 2 3 4 5 6 7 8  
1
Note 3  
• Uses the internal clock as the receive clock  
when the No. 0 Port is synchronous  
• When the No. 0 Port is asynchronous  
Enables transmit clock from the DCE (Mo-  
dem) side when the No. 0 Port is synchronous.  
(Clock is received at the TXC (2) terminal.)  
2
• Uses the internal clock as the send clock  
when the No. 0 Port is synchronous  
OFF  
• When the No. 0 Port is asynchronous  
For transmitting the send clock from the DTE  
(this card) when the No. 0 Port is synchro-  
nous. (Clock is transmitted from the TXC (1)  
terminal.)  
ON  
3
4
• For not transmitting the send clock from the  
DTE (this card) side when the No. 0 Port is  
synchronous  
OFF  
• When the No. 0 Port is asynchronous  
ON  
When the No. 0 Port is asynchronous  
When the No. 0 Port is synchronous  
OFF  
CHAPTER 4  
Page 56  
ND-45504 (E)  
Revision 2.0  
PN-AP00-A (AP00)  
CHECK  
Switch Settings (Continued)  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
SW0  
FUNCTION  
• Uses the internal clock as the receive  
clock when the No. 0 Port is synchro-  
nous.  
ON  
• When the No. 0 Port is asynchronous.  
5
Note 4  
Enables receive clock from the DCE (Mo-  
dem) side when the No. 0 Port is synchro-  
nous. (Clock is received at the RXC  
terminal)  
OFF  
Set No. 0 port forcibly in a state which DSR  
signal is always provided. Force DSR sig-  
nal high for port 0. No SMDR buffering.  
ON  
OFF  
ON  
6
Note 5  
Receive DSR signal from the DCE on No.  
0 port. Detect DSR signal from DCE for  
port 0. Allows SMDR records to buffer.  
Set No. 1 port forcibly in a state which DSR  
signal is always provided. Force DSR sig-  
nal high for port 1. No SMDR buffering.  
7
Note 5  
Receive DSR signal from the DCE on No.  
1 port. Detect DSR signal from DCE for  
port 1. Allows SMDR records to buffer.  
OFF  
ON  
Set No. 2 port forcibly in a state which  
DSR signal is always provided. Force DSR  
signal high for port 2. No SMDR buffering.  
8
Note 5  
Receive DSR signal from the DCE on No.  
2 port. Detect DSR signal from DCE for  
port 2. Allows SMDR records to buffer.  
OFF  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
ND-45504 (E)  
CHAPTER 4  
Page 57  
Revision 2.0  
PN-AP00-A (AP00)  
Note 1:  
Note 2:  
Set the groove on the switch knob to the desired switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
Note 3:  
The SW 1 is used to select the AP operating mode as shown below.  
SWITCH  
ON LINE  
OFF LINE  
SW 1-4  
SW 1-3  
SW 1-2  
SW 1-1  
OFF  
ON  
ON  
ON  
OFF  
OFF  
OFF  
ON  
On line : Normal operating mode. The AP should be always in the “On line”, other than when you delete the AP  
data.  
Off line : The mode for AP data clearing by the command CMD100/CMD101.  
Note 4:  
The use of the external clock (from the distant end) or the internal clock is determined by the following  
table:  
SW0  
CLOCK  
1
5
External  
Internal  
ON  
OFF  
OFF  
ON  
Note 5:  
When the DCE connected to the port does not provide a function to send the DSR signals, set the switch  
to ON. In this case, the AP00 card can not recognize the actual state of the DCE, so that the call records  
or system messages will not be stored in the memory buffer on the AP00 card even if the cable is discon-  
nected from the DCE.  
When the switch is set to OFF, the call records or system messages will be stored when the cable is dis-  
connected, and will be sent when the cable is re-connected.  
CHAPTER 4  
Page 58  
ND-45504 (E)  
Revision 2.0  
PN-AP01 (AP01)  
PN-AP01 (AP01)  
1. Locations of Lamps, Switches, and Connectors  
SENSE  
RUN  
MB  
SW1  
L3  
L2  
L1  
L0  
RS0  
IP  
SW0  
PN-AP01 (AP01) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
L3  
Green  
Flashes at 120 IPM while this card is operating normally.  
Indication of the status of CTS signal on the RS-232C port.  
Indication of the status of DCD signal on the RS-232C port.  
Indication of the status of TXD signal on the RS-232C port  
Indication of the status of RXD signal on the RS-232C port.  
L2  
L0-L3  
L1  
Green  
L0  
ND-45504 (E)  
CHAPTER 4  
Page 59  
Revision 2.0  
PN-AP01 (AP01)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SENSE  
(Rotary SW)  
4 - F  
Set the switch to match the AP Number (04 - 15) to be set by  
CM05.  
AP NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
SW NO.  
Note 1  
0 - 3  
Not used  
UP  
MB(Toggle SW)  
For make-busy  
ON  
DOWN  
For normal operation  
Note 2  
SW1 (Piano Key  
SW)  
For normal operation  
Not used  
ON  
OFF  
ON  
1
2
3
For normal operation  
Not used  
OFF  
OFF  
ON  
4
3
2
1
For normal operation  
Not used  
OFF  
ON  
For normal operation  
Not used  
4
ON  
OFF  
CHAPTER 4  
Page 60  
ND-45504 (E)  
Revision 2.0  
PN-AP01 (AP01)  
CHECK  
Switch Settings (Continued)  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
SW0 (Dip SW)  
1
2
3
Always set to OFF  
Always set to OFF  
OFF  
OFF  
OFF  
OFF  
ON  
1 2 3 4  
Always set to OFF  
Always set to OFF  
4
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the desired switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
CHAPTER 4  
Page 61  
Revision 2.0  
PN-BRTA (BRI)  
PN-BRTA (BRI)  
1. Locations of Lamps, Switches, and Connectors  
SENS  
RUN  
MB  
B1  
B2  
D
ALM  
SW0  
SW1  
PN-BRTA (BRI) Card  
CHAPTER 4  
Page 62  
ND-45504 (E)  
Revision 2.0  
PN-BRTA (BRI)  
(2) Lamp Indications  
Lamp Indications on the PN-BRTA (BRI) Card  
FUNCTION  
LAMP NAME  
COLOR  
RUN  
Green  
Flashes at 120 IPM while this card is operating normally.  
B1 channel status  
ON:  
OFF:  
Busy  
Idle  
B1  
B2  
Green  
Green  
Flash (60 IPM):Make Busy  
B2 channel status  
ON:  
OFF:  
Busy  
Idle  
Flash (60 IPM):Make Busy  
D channel status  
D
Green  
Red  
ON:  
OFF:  
Busy  
Idle  
Transmission line fault status  
ON:  
ALM  
Line fault  
OFF:  
Normal operation  
ND-45504 (E)  
CHAPTER 4  
Page 63  
Revision 2.0  
PN-BRTA (BRI)  
(3) Switch Settings  
Switch Settings on the PN-BRTA (BRI) Card  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
SENS  
4 - F  
Set the switch to match the AP Number (04 - 15) as set by CM05.  
(Rotary SW)  
04 05 06 07 08 09 10 11 12 13 14 15  
AP NO.  
SW NO.  
0
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 - 3  
Not used  
MB (Toggle SW)  
For make-busy  
UP  
ON  
For normal operation  
DOWN  
Note 2  
SW0 (Dip SW)  
For normal operation (BRI mode)  
Not used  
ON  
1
OFF  
ON  
1 2 3 4  
Clock signal from a master office is sent to the PLO of  
MP card according to the switch setting of SW0-3.  
ON  
2
Note 3  
Clock signal from a master office is not sent to the PLO  
of MP card.  
OFF  
ON  
Clock signal is sent to PLO 0 of MP card.  
Clock signal is sent to PLO 1 of MP card.  
For normal operation  
3
Note 3  
OFF  
ON  
4
1
OFF  
Not used  
SW1 (Dip SW)  
For terminating the transmitting side of channels B1 and  
B2 with 100 ohms.  
ON  
ON  
1 2  
To remove the terminating resistor on the transmitting  
side of channels B1 and B2.  
OFF  
For terminating the receiving side of channels B1 and B2  
with 100 ohms.  
ON  
2
To remove the terminating resistor on the receiving side  
of channels B1 and B2.  
OFF  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the desired switch position.  
When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
CHAPTER 4  
Page 64  
ND-45504 (E)  
Revision 2.0  
PN-BRTA (BRI)  
Note 3:  
Set SW0-2 and SW0-3 as follows.  
No. of BRI  
BRI 0  
BRI 1  
BRI 2  
....  
....  
BRI 11  
REMARKS  
SW  
CONDITIONS  
SW SW SW SW SW SW  
0-2 0-3 0-2 0-3 0-2 0-3  
SW SW  
0-2 0-3  
When one BRI is  
provided.  
The MP card will receive the clock signal  
from BRI 0 at its PLO 0 input.  
ON ON  
When more than  
one BRI is pro-  
vided.  
The MP card will receive the clock signal  
from BRI 0 at its PLO 0 input under nor-  
mal conditions.  
ON ON ON OFF OFF ON  
.... OFF ON Should a clock failure occur on BRI 0, the  
MP card will automatically switch to the  
PLO 1 input, and so derive the clock from  
BRI 1.  
ND-45504 (E)  
CHAPTER 4  
Page 65  
Revision 2.0  
PN-2BRTC (BRI)  
PN-2BRTC (BRI)  
1. Locations of Lamps, Switches, and connectors  
SENS  
RUN  
MB  
B21  
B11  
D1  
ALM1  
B20  
B10  
D0  
ALM0  
SW11  
SW10  
SW0  
PN-2BRTC (BRI) Card  
CHAPTER 4  
Page 65-1  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
PN-2BRTC (BRI)  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
RUN  
COLOR  
Green  
Red  
FUNCTION  
Flashes at 120 IPM while this card is operating normally.  
B21  
No.1 Circuit  
B2 channel status  
ON:  
OFF:  
Busy  
Idle  
Flash (60 IPM): Make Busy  
B11  
Red  
B1 channel status  
ON:  
OFF:  
Busy  
Idle  
Flash (60 IPM): Make Busy  
D1  
ALM1  
B20  
Green  
Red  
D channel status  
ON: Busy  
OFF: Idle  
Transmission line fault status  
ON: Line fault  
OFF: Normal operation  
Red  
No.0 Circuit  
B2 channel status  
ON:  
OFF:  
Busy  
Idle  
Flash (60 IPM): Make Busy  
B10  
Red  
B1 channel status  
ON:  
OFF:  
Busy  
Idle  
Flash (60 IPM): Make Busy  
D0  
Green  
Red  
D channel status  
ON: Busy  
OFF: Idle  
ALM0  
Transmission line fault status  
ON: Line fault  
OFF: Normal operation  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 65-2  
Revision 2.1  
PN-2BRTC (BRI)  
3. Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SENS  
(Rotary SW)  
4 ~ F  
Set the switch to match the AP Number (04-15) as set by  
CM05.  
AP No.  
SW No.  
04 05 06 07 08 09 10 11 12 13 14 15  
0
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 ~ 3  
Not used  
UP  
MB (Toggle SW)  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
SW0, SW10  
(Dip SW)  
For terminating the transmitting side  
of channels B1 and B2 with 100 ohms.  
ON  
OFF  
ON  
1
2
1
2
ON  
To remove the terminating resistor on  
the transmitting side of channels B1  
and B2.  
For terminating the receiving side of  
channels B1 and B2 with 100 ohms.  
To remove the terminating resistor on  
the receiving side of channels B1 and  
B2.  
OFF  
CHAPTER 4  
Page 65-3  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
PN-2BRTC (BRI)  
CHECK  
Switch Settings (Continued)  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
SW11 (Dip SW)  
For normal operation (BRI mode)  
Not used  
ON  
1
OFF  
ON  
1 2 3 4  
Output clock signals according to the  
switch setting of SW11-3.  
ON  
2
Note 3  
OFF  
ON  
Do not output clock signals.  
Output clock signals to PLO 0 of MP.  
Output clock signals to PLO 1 of MP.  
For normal operation  
3
Note 3  
OFF  
ON  
4
OFF  
Not used  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION  
column indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1: Set the groove on the switch knob to the desired switch position.  
Note 2: When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
Note 3: The system can supply clock signals from two clock supply routes.  
In normal condition, the system synchronizes to the clock signals supplied on the PLO 0 of MP card via  
the Back Wiring Board, and if the clock signals are failed, the clock supply route takes over to PLO1  
automatically. Set SW11-2 and SW11-3 as follows.  
No. of  
BRI 0  
BRI 1  
BRI 2  
----  
----  
BRI 11  
BRI  
REMARKS  
SW  
SW SW SW SW SW SW  
11-2 11-3 11-2 11-3 11-2 11-3  
SW SW  
11-2 11-3  
CONDITIONS  
The clock signals are supplied to the  
PLO through No. 0 circuit the BRI. If  
the clock supply route of No. 0 circuit  
is failed, the clock supply route of No.  
1 circuit takes over automatically.  
When one BRI is  
provided.  
ON ON  
The system can supply the clock  
signals from BRI 0 or BRI 1. The  
system is synchronized to the BRI 0  
When more than  
one BRI is pro-  
vided.  
ON ON ON OFF OFF ON ---- OFF ON clock signals normally, and if both  
No. 0 circuit clock supply route and  
No. 1 circuit clock supply route is  
failed, the BRI 1 takes over.  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 65-4  
Revision 2.1  
PN-CC00 (ETHER)  
PN-CC00 (ETHER)  
1. Locations of Lamps, Switches, and Connectors  
PN-CC00  
PZ-M397  
ETHER  
RUN  
SW  
RUN  
SW  
ERR  
S1  
ERR  
S1  
S2  
S2  
S3  
S3  
IP  
SW31  
SW51  
PN-CC00 (ETHER) Card  
CHAPTER 4  
Page 66  
ND-45504 (E)  
Revision 2.0  
PN-CC00 (ETHER)  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
RUN  
ERR  
S1  
Green  
Red  
Steadily lights while this card is operating normally.  
Flashes at 120 IPM when system error occurs.  
Lights when it is transmitting or receiving the data.  
Lights when it can transmit or receive the data.  
Lights when the power sets ON.  
Green  
Green  
Green  
S2  
S3  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 67  
Revision 2.1  
PN-CC00 (ETHER)  
(3) Switch Settings  
Switch Settings  
SETTING  
SWITCH  
NAME  
SWITCH  
NUMBER  
FUNCTION  
CHECK  
POSITION  
SW  
(Rotary SW)  
Always set to 0  
Not used  
0
1-F  
SW51 (Dip SW)  
1 (D15)  
2 (D14)  
3 (D13)  
4 (D12)  
5 (D11)  
ON  
ON  
ON:0 OFF:1  
MAC ADDRESS  
SWITCH SETTING  
ON  
1 2 3 4 5 6 7 8  
ON  
00003225 1 X X X  
(HEX)  
OFF  
ON  
SW51-1 (D15) ON  
SW51-2 (D14) ON  
SW51-3 (D13) ON  
SW51-4 (D12) OFF  
Note  
Fixed  
OFF  
ON  
6 (D10)  
7 (D9)  
8 (D8)  
1 (D7)  
2 (D6)  
3 (D5)  
4 (D4)  
5 (D3)  
6 (D2)  
7 (D1)  
8 (D0)  
OFF  
ON  
SW51-5 (D11) ON/OFF  
SW51-6 (D10) ON/OFF  
OFF  
ON  
SW51-7 (D9)  
SW51-8 (D8)  
ON/OFF  
ON/OFF  
OFF  
ON  
SW31 (Dip SW)  
OFF  
ON  
SW31-1 (D7)  
SW31-2 (D6)  
SW31-3 (D5)  
SW31-4 (D4)  
ON/OFF  
ON/OFF  
ON/OFF  
ON/OFF  
ON  
1 2 3 4 5 6 7 8  
OFF  
ON  
Note  
OFF  
ON  
SW31-5 (D3)  
SW31-6 (D2)  
SW31-7 (D1)  
SW31-8 (D0)  
ON/OFF  
ON/OFF  
ON/OFF  
ON/OFF  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
Note: Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more  
than one PBX is installed in the same network, assign the lower 3 digits of the following MAC address by  
SW31 and SW51 to prevent duplicate addresses.  
000032251  
XXX (HEX)  
According to the switch setting of SW51 (D11-D8) and SW31 (D7-D0).  
Fixed  
CHAPTER 4  
Page 68  
ND-45504 (E)  
Revision 2.0  
PN-CC01 (ETHER)  
PN-CC01 (ETHER)  
1. Location of Lamps, Switches, and Connectors  
SW1  
SW2  
RUN  
MB  
LINK  
XMT  
RCV  
RVP  
ERR  
10 BASE-T  
IP  
PN-CC01 (ETHER) Card  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 68-1  
Revision 2.1  
PN-CC01 (ETHER)  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
RUN  
COLOR  
Green  
Green  
Green  
Green  
Green  
Flashes at 60 IPM while this card is operating normally.  
Lights when link is established.  
LINK  
XMT  
Lights when it is transmitting the data.  
Lights when it is receiving the data.  
Lights only when it is receiving the data with its own IP address.  
Not used  
RCV  
RVP  
ERR  
CHAPTER 4  
Page 68-2  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
PN-CC01 (ETHER)  
CHECK  
3. Switch Settings  
Switch Settings  
SETTING  
SWITCH  
NAME  
SWITCH  
NUMBER  
FUNCTION  
POSITION  
MB (Toggle SW)  
UP  
For make-busy  
ON  
For normal operation  
DOWN  
Note 1  
SW1 (Dip SW)  
1 (D15)  
2 (D14)  
3 (D13)  
4 (D12)  
5 (D11)  
ON  
ON  
ON: 0 OFF: 1  
SWITCH SETTING  
MAC ADDRESS  
ON  
1 2 3 4 5 6 7 8  
ON  
00004CA4 X X X X  
(HEX)  
OFF  
ON  
SW1-1 (D15)  
ON/OFF  
ON/OFF  
ON/OFF  
ON/OFF  
Note 2  
Fixed  
SW1-2 (D14)  
SW1-3 (D13)  
SW1-4 (D12)  
OFF  
ON  
6 (D10)  
7 (D9)  
8 (D8)  
1 (D7)  
2 (D6)  
3 (D5)  
4 (D4)  
5 (D3)  
6 (D2)  
7 (D1)  
8 (D0)  
OFF  
ON  
SW1-5 (D11)  
SW1-6 (D10)  
SW1-7 (D9)  
SW1-8 (D8)  
ON/OFF  
ON/OFF  
ON/OFF  
ON/OFF  
OFF  
ON  
OFF  
ON  
SW2 (Dip SW)  
OFF  
ON  
SW2-1 (D7)  
SW2-2 (D6)  
SW2-3 (D5)  
SW2-4 (D4)  
ON/OFF  
ON/OFF  
ON/OFF  
ON/OFF  
ON  
1 2 3 4 5 6 7 8  
OFF  
ON  
Note 2  
OFF  
ON  
SW2-5 (D3)  
SW2-6 (D2)  
SW2-7 (D1)  
SW2-8 (D0)  
ON/OFF  
ON/OFF  
ON/OFF  
ON/OFF  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
ON  
OFF  
Note 1: When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the Circuit card.  
Note 2: Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more  
than one PBX is installed in the same network, assign the lower 4 digits of the following MAC address by  
SW1 and SW2 to prevent duplicate addresses.  
00004CA4  
XX XX (HEX)  
According to the switch setting of SW2 (D7-D0)  
According to the switch setting of SW1 (D15-D8)  
Fixed  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 68-3  
Revision 2.1  
This page is for your notes.  
CHAPTER 4  
Page 68-4  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
PN-CK00 (PLO)  
PN-CK00 (PLO)  
1. Locations of Lamps, Switches, and Connectors  
SYNC  
PLO0  
PLO1  
ALM  
DRFT  
MB  
SW0  
PN-CK00 (PLO) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
SYNC  
Green  
Green  
Lights while clock signals from this card are sent out and are not DRIFT status.  
Lights while receiving clock signals from the network to the PLO0 input on this  
card.  
PLO0  
PLO1  
Lights while receiving clock signals from the network to the PLO1 input on this  
card.  
Green  
ALM  
Red  
Red  
Lights while clock signal from this card are not sent out.  
Lights while clock signals are DRIFT status.  
DRFT  
DRIFT:  
Means the status which the oscillation of clock signal from the PN-CK00 is not synchronized with  
the network.  
ND-45504 (E)  
CHAPTER 4  
Page 69  
Revision 2.0  
PN-CK00 (PLO)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
MB (Toggle SW)  
UP  
For make-busy  
ON  
For normal operation  
DOWN  
Note  
SW0 (Piano Key SW)  
Selection of PLO 0 (Phase Locked Oscillator)  
SWITCH NUMBER  
FUNCTION  
OFF  
1
2
8
7
6
5
4
3
2
1
2 MHz clock  
[For PN-30DTC/PN-30DTC-A/  
PN-2BRTC]  
ON  
ON  
1, 2  
1.5 MHz clock  
[For PN-24DTA/PN-24DTA-A]  
OFF  
ON  
192 kHz clock  
[For PN-BRTA]  
ON  
OFF  
OFF  
OFF  
Not used  
ON  
Selection of PLO 1 (Phase Locked Oscillator)  
SWITCH NUMBER  
FUNCTION  
3
4
2 MHz clock  
ON  
ON  
[For PN-30DTC/PN-30DTC-A/  
PN-2BRTC]  
3, 4  
1.5 MHz clock  
[For PN-24DTA/PN-24DTA-A]  
OFF  
ON  
192 kHz clock  
[For PN-BRTA]  
ON  
OFF  
OFF  
OFF  
Not used  
5 ~ 7  
8
Not used  
OFF  
ON  
PLO frequency hold circuit OFF  
PLO frequency hold circuit ON  
OFF  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION  
column indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
CHAPTER 4  
Page 70  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
PN-CK00 (PLO)  
Note 1: When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card.  
Note 2: When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows.  
SW2-2: OFF  
SW2-3: ON  
Note 3: When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and  
the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as fol-  
lows.  
PN-CK00 card  
SW0-1: OFF  
SW0-2: OFF  
SW0-3: OFF  
SW0-4: OFF  
SW0-8: ON  
PN-24DTA/PN-24DTA-A card  
SW-1: OFF  
PN-30DTC/PN-30DTC-A card  
SW-1: OFF  
SW-2: OFF  
SW-2: OFF  
Note 4: When using this card as a sub-master, set the SW0 switch on the PN-CK00 and the SW switch on the  
PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A as follows:  
For 1.5MHz interface:  
PN-CK00 card  
SW0-1: OFF  
SW0-2: ON  
PN-24DTA/PN-24DTA-A card  
SW-1: ON  
SW-2: OFF  
SW0-3: OFF  
SW0-4: ON*  
SW0-8: ON  
* Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI  
card is mounted in PIM0.  
For 2MHz interface:  
PN-CK00 card  
SW0-1: ON  
SW0-2: ON  
SW0-3: ON  
SW0-4: ON*  
SW0-8: ON  
PN-30DTC/PN-30DTC-A card  
SW-1: ON  
SW-2: OFF  
* Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI  
card is mounted in PIM0.  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 71  
Revision 2.1  
PN-24DTA (DTI)  
PN-24DTA (DTI)  
1. Locations of Lamps, Switches, and Connectors  
SENS  
RUN  
MB  
SW  
JPS  
CRC  
PCM  
FRM  
RMT  
AIS  
JPR1  
JPR0  
BL  
PN-24DTA (DTI) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
CRC  
PCM  
FRM  
RMT  
Green  
Red  
Flashes at 120 IPM while this card is operating normally.  
Lights when detecting Cyclic Redundancy Checking (CRC) errors.  
Lights when detecting PCM signal loss.  
Red  
Red  
Lights when detecting a Frame Alignment signal loss.  
Red  
Lights when receiving a Frame Alignment signal loss alarm from a distant office.  
Lights when a pattern of consecutive “1” bits is received. The distant office transmits this  
signal for a loop-back test.  
AIS  
Red  
Red  
B channel status  
ON  
OFF  
:
:
More than 10 channels are busy  
All channels are idle  
BL  
Flash (60 IPM):Only one channel is busy  
Flash (120 IPM):2 through 10 channels are busy  
CHAPTER 4  
Page 72  
ND-45504 (E)  
Revision 2.0  
PN-24DTA (DTI)  
CHECK  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
SENS  
4 - F  
Set the switch to match the AP Number (04 - 15) to be set by CM05.  
(Rotary SW)  
AP NO.  
SW NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 - 3  
Not used  
UP  
MB (Toggle SW)  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
SW  
Clock signal from a master office is sent to the PLO 0 in-  
put on the MP card.  
ON  
OFF  
ON  
(Piano Key SW)  
1
2
Clock signal from a master office is not sent to the PLO  
0 input on the MP card.  
OFF  
Clock signal from a master office is sent to the PLO 1 in-  
put on the MP card.  
8
7
6
5
4
3
2
1
Clock signal from a master office is not sent to the PLO  
1 input on the MP card.  
OFF  
ON  
OFF  
ON  
Remote loop-back  
3
4
5
6
For normal operation  
Local loop-back (AIS send)  
For normal operation  
OFF  
ON  
ON  
Set the equalizer according to the cable length  
between the PBX and the MDF.  
OFF  
ON  
SW-5 SW-6 SW-7  
CABLE LENGTH  
ON ON ON  
0 - 40 m ( 0 - 131.2 ft.)  
ON ON OFF 40 - 80 m (131.2 - 262.5 ft.)  
ON OFF ON 80 - 120 m (262.5 - 394 ft.)  
ON OFF OFF 120 - 160 m (394 - 525 ft.)  
OFF ON ON 160 - 200 m (525 - 656 ft.)  
OFF OFF OFF Signal is not sent  
OFF  
ON  
7
8
OFF  
OFF  
Always set to OFF  
ND-45504 (E)  
CHAPTER 4  
Page 73  
Revision 2.0  
PN-24DTA (DTI)  
Switch Settings (Continued)  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
JPS (Jumper pin)  
Neutral grounding on the transmitting line is not provid-  
ed.  
Right  
Left  
Neutral grounding on the transmitting line is provided.  
JPR0 (Jumper pin)  
Neutral grounding on the receiving line is not provided.  
Up  
Neutral grounding on the receiving line is provided.  
Down  
JPR1 (Jumper pin)  
Line impedance : 110 ohms  
Line impedance : 100 ohms  
Right  
Left  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the intended switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
Note 3:  
Set SW-1 and SW-2 as follows:  
DTI0  
DTI1  
DTI2  
DTI3  
DTI4  
NO. OF DTI  
SW  
REMARKS  
SW SW SW SW SW SW SW SW SW SW  
-1 -2 -1 -2 -1 -2 -1 -2 -1 -2  
CONDITIONS  
When one DTI is  
provided  
The MP card receives the clock  
signal from DTI0 at its PLO0 in-  
put.  
ON OFF  
When more than one  
DTI is provided  
The MP card receives the clock  
signal from DTI0 at its PLO0 in-  
put under normal conditions.  
ON OFF OFF ON OFF OFF OFF OFF OFF OFF Should a clock failure occur with  
DTI0, the MP card switches to the  
PLO1 input, which gets clock  
from DTI1.  
Note 4:  
When the PBX is the master office, set the SW-1 and SW-2 on all the DTI cards mounted in PIM0 to  
“OFF”.  
CHAPTER 4  
Page 74  
ND-45504 (E)  
Revision 2.0  
PN-24DTA-A (DTI)  
PN-24DTA-A (DTI)  
1. Location of Lamps, Switches, and Connectors  
[When Card Issue No. is before 5A]  
[When Card Issue No. is after 5B]  
SENS  
RUN  
MB  
SENS  
RUN  
MB  
SW  
SW  
AISS  
AISS  
MAS  
CRC  
CRC  
PCM  
FRM  
AIS  
PCM  
MAS  
FRM  
RMT  
RMT  
BL  
JPR1  
JPR0  
JPS  
JPR1  
JPR0  
JPS  
AIS  
BL  
PN-24DTA-A (DTI) Card  
Lamp Indications  
2. Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
CRC  
PCM  
FRM  
RMT  
Green  
Red  
Flashes at 120 IPM while this card is operating normally.  
Lights when detecting Cyclic Redundancy Checking (CRC) errors.  
Lights when detecting PCM signal loss.  
Red  
Red  
Lights when detecting a Frame Alignment signal loss.  
Red  
Lights when receiving a Frame Alignment signal loss alarm from a distant office.  
Lights when a pattern of consecutive “1” is received. The distant office transmits this signal  
for a loop-back test.  
AIS  
Red  
Red  
B channel status  
ON  
OFF  
:
:
More than 10 channels is busy  
All channels are idle  
BL  
Flash (60 IPM):Only one channel is busy  
Flash (120 IPM):2 through 10 channels are busy  
ND-45504 (E)  
CHAPTER 4  
Page 75  
Revision 2.0  
PN-24DTA-A (DTI)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
SENS  
4 ~ F  
Set the switch to match the AP Number (04 ~ 15) to be set by CM05.  
(Rotary SW)  
AP NO.  
SW NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
Not used  
UP  
Note 1  
0 ~ 3  
MB (Toggle SW)  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
Clock signal from a master office is sent to the PLO 0 in-  
put on the MP card.  
ON  
OFF  
ON  
1
2
Clock signal from a master office is not sent to the PLO  
0 input on the MP card.  
Clock signal from a master office is sent to the PLO 1 in-  
put on the MP card.  
SW  
(Piano Key SW)  
Clock signal from a master office is not sent to the PLO  
1 input on the MP card.  
OFF  
ON  
OFF  
Remote loop-back  
3
4
5
6
8
7
6
5
4
3
2
1
For normal operation  
Local loop-back (AIS send)  
For normal operation  
OFF  
ON  
OFF  
Set the equalizer according to the cable length between  
the PBX and the MDF.  
ON  
OFF  
SW-5  
SW-6  
SW-7  
CABLE LENGTH  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
ON 0 - 40 m ( 0 - 131.2 ft.)  
OFF 40 - 80 m (131.2 - 262.5 ft.)  
ON 80 - 120 m (262.5 - 394 ft.)  
OFF 120 - 160 m (394 - 525 ft.)  
ON 160 - 200 m (525 - 656 ft.)  
OFF Signal is not sent  
7
8
OFF  
ON  
OFF  
Always set to ON  
CHAPTER 4  
Page 76  
ND-45504 (E)  
Revision 2.0  
PN-24DTA-A (DTI)  
CHECK  
Switch Settings (Continued)  
SETTING  
SWITCH  
NAME  
SWITCH  
FUNCTION  
NUMBER POSITION  
JPS (Jumper pin)  
JPR0 (Jumper pin)  
JPR1 (Jumper pin)  
AISS (Jumper pin)  
MAS (Jumper pin)  
Neutral grounding on the transmitting line is not provid-  
ed.  
Right  
Left  
Right  
Left  
Neutral grounding on the transmitting line is provided.  
Neutral grounding on the receiving line is provided.  
Neutral grounding on the receiving line is not provided.  
Line impedance : 110 ohms  
Right  
Left  
Line impedance : 100 ohms  
AIS signal is sent out when make-busy or power on.  
AIS signal is not sent out when make-busy or power on.  
When this card is used for factory testing.  
When this card is used for normal operation.  
Right  
Left  
Right  
Left  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the intended switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
CHAPTER 4  
Page 77  
Revision 2.0  
PN-24DTA-A (DTI)  
Note 3: Set SW-1 and SW-2 as follows:  
DTI0  
DTI1  
DTI2  
DTI3  
DTI4  
No. of DTI  
SW  
REMARKS  
SW- SW- SW- SW- SW- SW- SW- SW- SW- SW-  
1
2
1
2
1
2
1
2
1
2
CONDITIONS  
The MP card will receive the  
clock signal from DTI0 at its  
PLO0 input.  
When one DTI is pro-  
vided.  
ON OFF  
The MP card will receive the  
clock signal from DTI0 at its  
PLO0 input, under normal condi-  
tions.  
Should a clock failure occur with  
DTI0, the MP card will switch to  
the PLO1 input which gets clock  
from DTI1.  
When more than one  
DTI is provided.  
ON OFF OFF ON OFF OFF OFF OFF OFF OFF  
Note 4:  
When the PBX is the master office, set the SW1-1 and SW1-2 on all the DTI cards mounted in PIM0 to  
“OFF”.  
CHAPTER 4  
Page 78  
ND-45504 (E)  
Revision 2.0  
PN-30DTC/30DTC-A (DTI)  
PN-30DTC/30DTC-A (DTI)  
1. Locations of Lamps, Switches, and Connectors  
SENS  
RUN  
MB  
SW  
PCM  
FRM  
MFRM  
RMT  
MRMT  
AIS  
JPS  
JPR  
BL  
JP  
PN-30DTC/30DTC-A (DTI) Card  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 78-1  
Revision 2.1  
PN-30DTC/30DTC-A (DTI)  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
RUN  
COLOR  
Green  
Red  
Flashes at 120 IPM when this card is normally operating.  
Lights when detecting PCM signal loss.  
PCM  
FRM  
Red  
Lights when detecting Frame Alignment signal loss.  
Lights when detecting Multi-Frame Alignment signal loss on time slot 16.  
MFRM  
Red  
Lights when receiving an alarm because Frame Alignment signal loss has been  
detected at the distant office.  
RMT  
Red  
Red  
Lights when receiving an alarm because Multi-Frame Alignment signal loss has  
been detected at the distant office.  
MRMT  
Lights when indicating that the pattern of consecutive “1” is being received. (The  
distant office transmits this signal for a loop-back test).  
AIS  
BL  
Red  
Red  
B channel status  
ON  
OFF  
: More than10 channels are busy  
: All channels are idle  
Flash (60 IPM) : Only one channel is busy  
Flash (120 IPM) : 2 to 10 channels are busy  
CHAPTER 4  
Page 78-2  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
PN-30DTC/30DTC-A (DTI)  
3. Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
SENS  
4 ~ F  
Set the switch to match the AP Number (04-15) as set by CM05.  
(Rotary SW)  
AP NO.  
SW NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
0
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 ~ 3  
Not used  
UP  
MB (Toggle SW)  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
SW  
Clock signal from master office is sent to PLO 0 on  
the MP card.  
ON  
OFF  
ON  
1
(Piano Key SW)  
Clock signal from master office is not sent to  
PLO 0 on the MP card.  
Note 3  
OFF  
8
7
6
5
4
3
2
1
Clock signal from master office is sent to PLO 1 on  
the MP card.  
2
Clock signal from master office is not sent to  
PLO 1 on the MP card.  
Note 3  
OFF  
ON  
OFF  
ON  
Remote loop-back  
3
4
5
For normal operation  
Local loop-back (AIS send)  
For normal operation  
ON  
OFF  
ON  
Transmission line cable: Coaxial (75 )  
Note 4  
Transmission line cable: Twisted-pair (120 )  
Always set to OFF  
OFF  
OFF  
OFF  
ON  
6
7
8
Always set to ON  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 78-3  
Revision 2.1  
PN-30DTC/30DTC-A (DTI)  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
JPS  
(Jumper pin)  
Balanced transmission  
(For twisted-pair cable)  
UP  
TA is grounded on the transmission line  
DOWN  
UP  
(For coaxial cable)  
Note 4  
JPR  
(Jumper pin)  
Balanced transmission  
(For twisted-pair cable)  
RA is grounded on the transmission line  
(For coaxial cable)  
DOWN  
RIGHT  
LEFT  
JP  
Line impedance: 75 ohms  
(Jumper pin)  
(For coaxial cable)  
Note 4  
Line impedance: 120 ohms  
(For twisted-pair cable)  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1: Set the groove on the switch knob to the intended switch position.  
Note 2: When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
CHAPTER 4  
Page 78-4  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
PN-30DTC/30DTC-A (DTI)  
Note 3: Set SW-1 and SW-2 as follows.  
No. of DTI  
SW  
DTI 0  
DTI 1  
DTI 2  
DTI 3  
REMARKS  
SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 SW-1 SW-2  
CONDITIONS  
The MP card will receive the clock  
signal from DTI 0 at its PLO 0 input.  
When one DTI is provided. ON  
OFF  
OFF  
The MP card will receive the clock  
signal from DTI 0 at its PLO 0 input,  
under normal conditions.  
When more than one DTI  
ON  
OFF  
ON  
OFF  
OFF  
OFF  
OFF Should a clock failure occur on  
DTI 0, the MP card will automatical-  
ly switch to the PLO 1 input, and so  
derive the clock from DTI 1.  
is provided.  
Note 4: Coaxial cable connection to the PN-30DTC/30DTC-A is not available in the U.S.  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
CHAPTER 4  
Page 78-5  
Revision 2.1  
This page is for your notes.  
CHAPTER 4  
Page 78-6  
Revision 2.1  
ND-45504 (E)  
Addendum-001  
JULY, 1998  
PN-ME00 (EXTMEM)  
PN-ME00 (EXTMEM)  
1. Locations of Lamps, Switches, and Connectors  
JP0  
SENS  
RUN  
JP2  
MB  
WP  
BAT  
CN0  
PN-ME00 (EXTMEM) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
WP  
Green  
Red  
Flashes at 120 IPM while this circuit card is operating normally.  
Lights when the RAM is being accessed.  
Lights indicating the status (Write Protect Switch status and the battery voltage  
status) of the SRAM card on this circuit card.  
WRITE PROTECT  
SWITCH STATUS  
BATTERY VOLTAGE  
STATUS  
LAMP STATUS  
BAT  
Red  
On  
Protect On  
OK  
Flash (60 IPM)  
Flash (120 IPM)  
Off  
Protect Off  
Protect On  
Protect Off  
Needs to be replaced  
Needs to be replaced  
OK  
ND-45504 (E)  
CHAPTER 4  
Page 79  
Revision 2.0  
PN-ME00 (EXTMEM)  
How to Handle the SRAM Card  
Mounting the SRAM Card  
Slide the lock switch downward (Lock Release), then remove the battery case from the SRAM card.  
Mount the battery on the battery case, then insert the battery case into the SRAM card.  
Slide the lock switch upward (Lock).  
Mount the SRAM card in the PN-ME00 card.  
Slide the write protect switch downward (Active).  
BATTERY CASE LOCK SWITCH  
WRITE PROTECT SWITCH  
DOWNWARD  
UPWARD  
L O C K  
ACTIVE  
LOCK  
PROTECT  
LOCK RELEASE  
FRONT  
Front View of the SRAM Card  
CHAPTER 4  
ND-45504 (E)  
Page 80  
Revision 2.0  
PN-ME00 (EXTMEM)  
Removing the SRAM Card  
Push the card slot bar of the PN-ME00 card.  
Remove the SRAM card.  
PN-ME00  
PUSH  
SRAM  
Removing the SRAM Card  
Replacing the SRAM Battery  
CAUTION  
To prevent loss of memory on an active system, the battery must be replaced when the SRAM card is installed on  
the PN-ME00, and the PN-ME00 is installed in the system. Also, power to the system must be “ON”.  
Slide the lock switch downward (Lock Release), then remove the battery case from the SRAM card.  
Replace the battery, then insert the battery case into the SRAM card.  
Slide the lock switch upward (Lock).  
ND-45504 (E)  
CHAPTER 4  
Page 81  
Revision 2.0  
PN-ME00 (EXTMEM)  
PN-ME00  
REMOVE THE  
BATTERY CASE  
LITHIUM BATTERY:  
BR2325 OR CR2325  
Replacing the SRAM Battery  
CHAPTER 4  
Page 82  
ND-45504 (E)  
Revision 2.0  
PN-ME00 (EXTMEM)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
FUNCTION  
CHECK  
SENSE  
(Rotary SW)  
4 - F  
Set the switch to match the AP Number (04 - 15) to be set by  
CM05.  
AP NO.  
SW NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 - 3  
Not used  
For make-busy  
MB(Toggle SW)  
UP  
For normal operation  
ON  
DOWN  
Note 2  
JP0 (Jumper pin)  
For normal operation  
UP  
Front  
Note 3  
JP2 (Jumper pin)  
For normal operation  
UP  
Front  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the desired switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
Note 3:  
Do not touch the JP0. If the jumper is pulled off, the data in the memory of the ME00 card is cleared.  
ND-45504 (E)  
CHAPTER 4  
Page 83  
Revision 2.0  
PN-4RSTB (MFR)  
PN-4RSTB (MFR)  
1. Locations of Lamps, Switches and Connectors  
SENS  
RUN  
MB  
SW  
OPE3  
OPE2  
OPE1  
OPE0  
PN-4RSTB (MFR) Card  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
RUN  
Green  
Flashes at 120 IPM while the circuit card is operating normally.  
• Lights when the corresponding circuit is in use.  
OPE  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
CHAPTER 4  
Page 84  
ND-45504 (E)  
Revision 2.0  
PN-4RSTB (MFR)  
CHECK  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
SENS  
(Rotary SW)  
Set the switch to match the AP Number (04 - 15) to be set by CM05.  
4 - F  
AP NO.  
SW NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 - 3  
Not used  
UP  
MB (Toggle SW)  
For make-busy  
For normal operation  
ON  
DOWN  
Note 2  
SW  
ON  
OFF  
ON  
For make-busy No. 0 circuit  
For normal operation  
1
2
3
4
(Piano Key SW)  
For make-busy No. 1 circuit  
For normal operation  
OFF  
OFF  
ON  
8
7
6
5
For make-busy No. 2 circuit  
For normal operation  
OFF  
ON  
For make-busy No. 2 circuit  
For normal operation  
4
3
2
1
OFF  
OFF  
OFF  
OFF  
ON  
5
6
7
8
Not used  
ON  
Always set to ON  
Note 1:  
Note 2:  
Set the groove on the switch knob onto the desired switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
CHAPTER 4  
Page 85  
Revision 2.0  
PN-4RSTC (CIR)  
PN-4RSTC (CIR)  
1. Locations of Lamps, Switches and Connectors  
SENSE  
RUN  
MB  
SW1  
BL3  
BL2  
BL1  
BL0  
JP0  
PN-4RSTC (CIR) Card  
Lamp Indications  
2. Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
Green  
Red  
Flashes at 120 IPM while the circuit card is operating normally.  
Lights when receiving a CALLER ID (CLASS SM) signal.  
BL0-3  
CHAPTER 4  
Page 86  
ND-45504 (E)  
Revision 2.0  
PN-4RSTC (CIR)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER  
SETTING  
POSITION  
FUNCTION  
CHECK  
SENSE  
4 - F  
Set the switch to match the AP Number (04 - 15) to be set by CM05.  
(Rotary SW)  
AP NO.  
SW NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
0 - 3  
Not used  
Note 1  
MB(Toggle SW)  
UP  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
SW1  
(Piano Key SW)  
ON  
OFF  
ON  
For make-busy No. 0 circuit  
For normal operation  
1
2
3
4
For make-busy No. 1 circuit  
For normal operation  
OFF  
OFF  
ON  
4
3
2
1
For make-busy No. 2 circuit  
For normal operation  
OFF  
ON  
For make-busy No. 3 circuit  
For normal operation  
ON  
OFF  
JP0 (Jumper pin)  
For normal operation  
Right  
Note 1:  
Note 2:  
Set the groove on the switch knob onto the desired switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
CHAPTER 4  
Page 87  
Revision 2.0  
PN-SC00 (CCH)  
PN-SC00 (CCH)  
1. Locations of Lamps, Switches and Connectors  
SW1  
SENS  
RUN  
MB  
SW0  
LC  
LPB  
RS  
PN-SC00 (CCH) Card  
Lamp Indications  
2. Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
RUN  
Green  
Flashes at 120 IPM while this card is operating normally.  
Lights when communications are normally ongoing with the common signalling channel  
data links connected.  
LC  
Green  
Green  
LPB  
Lights when a loop-back test is in progress.  
CHAPTER 4  
Page 88  
ND-45504 (E)  
Revision 2.0  
PN-SC00 (CCH)  
CHECK  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
4 - F  
Set the switch to match the AP Number (04 - 15) to be set by CM05.  
SENS  
(Rotary SW)  
AP NO.  
SW NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 - 3  
Not used  
MB(Toggle SW)  
UP  
For make-busy  
For normal operation  
ON  
DOWN  
Note 2  
SW0  
(Piano Key SW)  
ON  
OFF  
ON  
Loop-back test  
1
2
For normal operation  
Analog interface  
Digital interface  
OFF  
OFF  
4
3
2
1
RS-232C RTS signal (to MODEM) ON  
Note 3  
ON  
3
4
OFF  
ON  
RS-232C RTS signal (to MODEM) OFF  
Always set to ON  
ON  
ND-45504 (E)  
CHAPTER 4  
Page 89  
Revision 2.0  
PN-SC00 (CCH)  
Switch Settings (Continued)  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
• Common channel signalling data transmission speed  
(For Digital Interface)  
ON  
1
OFF  
TRANSMISSION SW  
SW  
1-2  
SW  
1-3  
SW  
1-4  
SW  
1-5  
ON  
SPEED  
1-1  
2
48Kbps ¨  
48Kbps ¦  
56Kbps  
64Kbps  
ON ON OFF OFF ON  
ON ON ON OFF ON  
ON ON OFF ON ON  
ON ON ON ON ON  
OFF  
ON  
3
SW1(Dip SW)  
OFF  
• Common channel signalling data transmission speed  
(For Analog Interface)  
ON  
ON  
4
1 2 3 4 5 6 7 8  
Set switches (SW1-1 - SW1-5) to OFF.  
OFF  
ON  
5
OFF  
A-Law  
ON  
6
µ-law  
OFF  
Always set to OFF  
Always set to OFF  
7
8
OFF  
OFF  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the desired switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
Note 3:  
Note 4:  
This setting is available when SW0-2 is set to ON (Analog Interface).  
The followimg two kinds of rate adaptation method are available when using 48 Kbps data transmis-  
sion. The rate adaptation method must be set to match the rate adaptation of the master office.  
SW1-3: OFF  
SW1-3: ON  
1
2
48 Kbps  
48 Kbps  
1
1
1
1
Data  
Data  
CHAPTER 4  
Page 90  
ND-45504 (E)  
Revision 2.0  
PN-SC01 (DCH)  
PN-SC01 (DCH)  
1. Locations of Lamps, Switches and Connectors  
SW1  
SENS  
RUN  
MB  
SW0  
LC  
LPB  
PN-SC01 (DCH) Card  
Lamp Indications  
2. Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
Flashes at 120 IPM while this card is operating normally.  
RUN  
LC  
Green  
Green  
Green  
Lights when communications are normally ongoing with the D channel data links connected.  
Not used.  
LPB  
ND-45504 (E)  
CHAPTER 4  
Page 91  
Revision 2.0  
PN-SC01 (DCH)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER  
SETTING  
POSITION  
FUNCTION  
CHECK  
SENS  
4 - F  
Set the switch to match the AP Number (04 - 15) to be set by CM05.  
(Rotary SW)  
AP NO.  
SW NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 - 3  
Not used  
UP  
MB(Toggle SW)  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
SW0  
(Piano Key SW)  
OFF  
ON  
AT&T Interface  
1
Northern Telecom Interface  
No deletion  
OFF  
ON  
OFF  
2
3
Delete the first three digits of all 011 International Calls.  
Always set to OFF  
4
3
2
1
OFF  
4
Always set to ON  
ON  
ON  
SW1 (Dip SW)  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
1
2
3
4
5
6
7
8
Always set to OFF  
Always set to OFF  
Always set to OFF  
Always set to OFF  
Always set to OFF  
Always set to OFF  
Always set to OFF  
Always set to OFF  
ON  
1 2 3 4 5 6 7 8  
CHAPTER 4  
Page 92  
ND-45504 (E)  
Revision 2.0  
PN-SC01 (DCH)  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob onto the intended switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
CHAPTER 4  
Page 93  
Revision 2.0  
PN-SC02 (ICH)  
PN-SC02 (ICH)  
1. Locations of Lamps, Switches, and Connectors  
SENS  
RUN  
MB  
DOPE1  
DOPE0  
SW0  
PN-SC02 (ICH) Card  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
RUN  
Green  
Flashes at 120 IPM while this card is operating normally.  
ON: No. 0 circuit D channel link is connected.  
OFF: No. 0 circuit D channel link is not connected.  
DOPE0  
DOPE1  
Green  
Green  
ON: No. 1 circuit D channel link is connected.  
OFF: No. 1 circuit D channel link is not connected.  
CHAPTER 4  
Page 94  
ND-45504 (E)  
Revision 2.0  
PN-SC02 (ICH)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
SENS  
4 - F  
Set the switch to match the AP Number (04 - 15) to be set by CM05.  
(Rotary SW)  
AP NO.  
SW NO.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 - 3  
Not used  
MB (Toggle SW)  
UP  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
SW0  
(Piano Key SW)  
1
2
3
Always set to OFF  
Always set to OFF  
Always set to OFF  
Always set to ON  
OFF  
OFF  
OFF  
OFF  
4
3
2
1
4
ON  
ON  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the desired switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
CHAPTER 4  
Page 95  
Revision 2.0  
PN-SC03 (ICH)  
PN-SC03 (ICH)  
1. Locations of Lamps, Switches, and Connectors  
SENSE  
RUN  
MB  
DOPE7  
DOPE6  
DOPE5  
DOPE4  
DOPE3  
DOPE2  
DOPE1  
DOPE0  
PN-SC03 (ICH) Card  
2. Lamp Indications  
Lamp Indications on ICH Card  
FUNCTION  
LAMP NAME  
COLOR  
RUN  
Green  
Green  
Green  
Green  
Green  
Green  
Green  
Green  
Green  
Flashes at 120 IPM while the card is operating normally.  
Lights when No.7 circuit D channel link is connected.  
Lights when No.6 circuit D channel link is connected.  
Lights when No.5 circuit D channel link is connected.  
Lights when No.4 circuit D channel link is connected.  
Lights when No.3 circuit D channel link is connected.  
Lights when No.2 circuit D channel link is connected.  
Lights when No.1 circuit D channel link is connected.  
Lights when No.0 circuit D channel link is connected.  
DOPE7  
DOPE6  
DOPE5  
DOPE4  
DOPE3  
DOPE2  
DOPE1  
DOPE0  
CHAPTER 4  
Page 96  
ND-45504 (E)  
Revision 2.0  
PN-SC03 (ICH)  
(3) Switch Settings  
Switch Settings on ICH Card  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
SENSE  
4 ~ F  
Set the switch to match the AP Number (04 ~ 15) to be set by CM05.  
(Rotary SW)  
AP No.  
SW No.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 ~ 3  
Not used  
UP  
MB (Toggle SW)  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the intended switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
CHAPTER 4  
Page 97  
Revision 2.0  
PN-SC03 (CSH)  
PN-SC03 (CSH)  
1. Locations of Lamps, Switches, and Connectors  
SENSE  
RUN  
MB  
DOPE7  
DOPE6  
DOPE5  
DOPE4  
DOPE3  
DOPE2  
DOPE1  
DOPE0  
PN-SC03 (CSH) Card  
CHAPTER 4  
Page 98  
ND-45504 (E)  
Revision 2.0  
PN-SC03 (CSH)  
(2) Lamp Indications  
Lamp Indications on CSH Card  
FUNCTION  
LAMP NAME  
COLOR  
RUN  
Green  
Green  
Green  
Green  
Green  
Green  
Green  
Green  
Green  
Flashes at 120 IPM while the card is operating normally.  
Lights when No.7 circuit D channel link is connected.  
Lights when No.6 circuit D channel link is connected.  
Lights when No.5 circuit D channel link is connected.  
Lights when No.4 circuit D channel link is connected.  
Lights when No.3 circuit D channel link is connected.  
Lights when No.2 circuit D channel link is connected.  
Lights when No.1 circuit D channel link is connected.  
Lights when No.0 circuit D channel link is connected.  
DOPE7  
DOPE6  
DOPE5  
DOPE4  
DOPE3  
DOPE2  
DOPE1  
DOPE0  
3. Switch Settings  
Switch Settings on CSH Card  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
SENSE  
4 ~ F  
Set the switch to match the AP Number (04 ~ 15) to be set by CM05.  
(Rotary SW)  
AP No.  
SW No.  
04 05 06 07 08 09 10 11 12 13 14 15  
4
5
6
7
8
9
A
B
C
D
E
F
Note 1  
0 ~ 3  
Not used  
UP  
MB (Toggle SW)  
For make-busy  
ON  
For normal operation  
DOWN  
Note 2  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note 1:  
Note 2:  
Set the groove on the switch knob to the intended switch position.  
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit  
card.  
ND-45504 (E)  
CHAPTER 4  
Page 99  
Revision 2.0  
4. LAMP INDICATIONS AND SWITCH SETTINGS OF LINE/TRUNK CIRCUIT CARDS  
Table 4-3 below shows the line/trunk circuit cards to be explained in this section.  
Table 4-3 Table of Line /Trunk Circuit Cards  
EXISTENCE OF  
EXISTENCE OF  
EXTRACTION/INSER-  
NAME  
(FUNCTIONAL NAME)  
REFERENCE  
PAGE  
LAMPS  
X: PROVIDED  
SWITCHES  
X: PROVIDED  
TION WITH POWER ON  
X: ALLOWED  
: NOT PROVIDED  
: NOT PROVIDED  
: NOT ALLOWED  
PN-2AMPA (AMP)  
PN-AUCA (AUC)  
PN-CFTA (CFT)  
PN-4COTB (COT)  
PN-4COTG (COT)  
PN-2DATA (DAT)  
PN-DK00 (DK)  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
101  
102  
103  
104  
105  
106  
108  
109  
110  
111  
112  
113  
114  
115  
116  
117  
118  
121  
124  
125  
126  
129  
130  
131  
133  
X
PN-4DITB (DIT)  
PN-2DLCB (DLC)  
PN-2DLCC (DLC)  
PN-2DLCN (DLC)  
PN-4DLCA (DLC)  
PN-4DLCD (DLC)  
PN-4DLCF (DLC)  
PN-4DLCM (DLC)  
PN-4DLCQ (DLC)  
PN-2DPCB (DPC)  
PN-2ILCA (ILC)  
PN-4LCD/4LCD-A (LC)  
PN-4LCJ (LC)  
X
X
PN-M03 (M03)  
PN-2ODTA (ODT)  
PN-8RSTA (PBR)  
PN-TNTA (TNT)  
PN-2CSIA (CSI)  
X
X
CHAPTER 4  
Page 100  
ND-45504 (E)  
Revision 2.0  
PN-2AMPA (AMP)  
PN-2AMPA (AMP)  
1. Locations of Lamps, Switches and Connectors  
BL1  
BL0  
PN-2AMPA (AMP) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the corresponding circuit is in use.  
BL0, 1  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 101  
Revision 2.0  
PN-AUCA (AUC)  
PN-AUCA (AUC)  
1. Locations of Lamps, Switches and Connectors  
BL1  
BL0  
CN1  
PN-AUCA (AUC) Card  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
• Remains lit when the corresponding circuit is in use.  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
BL0, 1  
Red  
3. Switch Settings  
This card has no switches.  
CHAPTER 4  
ND-45504 (E)  
Page 102  
Revision 2.0  
PN-CFTA (CFT)  
PN-CFTA (CFT)  
1. Locations of Lamps, Switches and Connectors  
BL1  
PN-CFTA (CFT) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the card is in use.  
BL0  
Red  
• Flashes (60 IPM) When the circuit on the card is in the make-busy state on the system data  
for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 103  
Revision 2.0  
PN-4COTB (COT)  
PN-4COTB (COT)  
1. Locations of Lamps, Switches and Connectors  
BL3  
BL2  
BL1  
BL0  
CN1  
PN-4COTB (COT) Card  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
• Remains lit when the corresponding circuit is in use.  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
BL0 - 3  
Red  
3. Switch Settings  
This card has no switches.  
CHAPTER 4  
ND-45504 (E)  
Page 104  
Revision 2.0  
PN-4COTG (COT)  
PN-4COTG (COT)  
1. Locations of Lamps, Switches and Connectors  
BL3  
BL2  
BL1  
BL0  
CN1  
PN-4COTG (COT) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the corresponding circuit is in use.  
BL0 - 3  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 105  
Revision 2.0  
PN-2DATA (DAT)  
PN-2DATA (DAT)  
1. Locations of Lamps, Switches and Connectors  
BL1  
BL0  
SW  
PN-2DATA (DAT) Card  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
• Remains lit when the corresponding circuit is in use.  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
BL0, 1  
Red  
CHAPTER 4  
Page 106  
ND-45504 (E)  
Revision 2.0  
PN-2DATA (DAT)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
Data write into the No.1 circuit is disabled.  
Data write into the No.1 circuit is enabled.  
Data write into the No.1 circuit is disabled.  
Data write into the No.1 circuit is enabled.  
ON  
SW  
SW-0  
(Piano Key SW)  
ON  
OFF  
SW1  
SW0  
ON  
SW-1  
OFF  
OFF  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
ND-45504 (E)  
CHAPTER 4  
Page 107  
Revision 2.0  
PN-DK00 (DK)  
PN-DK00 (DK)  
1. Locations of Lamps, Switches and Connectors  
PN-DK00 (DK) Card  
2. Lamp Indications  
This card has no indicator lamps.  
3. Switch Settings  
This card has no switches.  
CHAPTER 4  
ND-45504 (E)  
Page 108  
Revision 2.0  
PN-4DITB (DIT)  
PN-4DITB (DIT)  
1. Locations of Lamps, Switches, and Connectors  
BL3  
BL2  
BL1  
BL0  
PN-4DITB (DIT) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
BL0 ~ 3  
COLOR  
FUNCTION  
• Light when the corresponding circuit is in use.  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or  
the system data for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 109  
Revision 2.0  
PN-2DLCB (DLC)  
PN-2DLCB (DLC)  
1. Locations of Lamps, Switches and Connectors  
BL1  
BL0  
CN0  
PN-2DLCB (DLC) Card  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
• Remains lit when the corresponding circuit is in use.  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
BL0 , 1  
Red  
3. Switch Settings  
This card has no switches.  
CHAPTER 4  
ND-45504 (E)  
Page 110  
Revision 2.0  
PN-2DLCC (DLC)  
PN-2DLCC (DLC)  
1. Locations of Lamps, Switches and Connectors  
BL1  
BL0  
PN-2DLCC (DLC) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the corresponding circuit is in use.  
BL0 , 1  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 111  
Revision 2.0  
PN-2DLCN (DLC)  
PN-2DLCN (DLC)  
1. Locations of Lamps, Switches and Connectors  
BL1  
BL0  
CN0  
PN-2DLCN (DLC) Card  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
• Remains lit when the corresponding circuit is in use.  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
BL0, 1  
Red  
3. Switch Settings  
This card has no switches.  
CHAPTER 4  
ND-45504 (E)  
Page 112  
Revision 2.0  
PN-4DLCA (DLC)  
PN-4DLCA (DLC)  
1. Locations of Lamps, Switches and Connectors  
BL3  
BL2  
BL1  
BL0  
PN-4DLCA (DLC) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the corresponding circuit is in use.  
BL0 - 3  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 113  
Revision 2.0  
PN-4DLCD (DLC)  
PN-4DLCD (DLC)  
1. Locations of Lamps, Switches and Connectors  
BL3  
BL2  
BL1  
BL0  
PN-4DLCD (DLC) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the corresponding circuit is in use  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the  
system data for this card is not assigned  
BL0-3  
Red  
3. Switch Settings  
This card has no switches.  
CHAPTER 4  
ND-45504 (E)  
Page 114  
Revision 2.0  
PN-4DLCF (DLC)  
PN-4DLCF (DLC)  
1. Locations of Lamps, Switches and Connectors  
BL3  
BL2  
BL1  
BL0  
CN1  
PN-4DLCF (DLC) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the corresponding circuit is in use.  
BL0 - 3  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 115  
Revision 2.0  
PN-4DLCM (DLC)  
PN-4DLCM (DLC)  
1. Locations of Lamps, Switches and Connectors  
BL3  
BL2  
BL1  
BL0  
PN-4DLCM (DLC) Card  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
• Remains lit when the corresponding circuit is in use.  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
BL0-3  
Red  
3. Switch Settings  
This card has no switches.  
CHAPTER 4  
ND-45504 (E)  
Page 116  
Revision 2.0  
PN-4DLCQ (DLC)  
PN-4DLCQ (DLC)  
1. Locations of Lamps, Switches and Connectors  
BL3  
BL2  
BL1  
BL0  
PN-4DLCQ (DLC) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the corresponding circuit is in use.  
BL0-3  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 117  
Revision 2.0  
PN-2DPCB (DPC)  
PN-2DPCB (DPC)  
1. Location of Lamps, Switches and Connectors  
RSC1  
SDT1  
RDR1  
CDI1  
BL1  
LB11  
LB12  
BL0  
LB01  
LB02  
RSC0  
SDT0  
RDR0  
CDI0  
SW1  
SW0  
XCN1  
XCN0  
RS1  
RS0  
PN-2DPCB (DPC) Card  
CHAPTER 4  
Page 118  
ND-45504 (E)  
Revision 2.0  
PN-2DPCB (DPC)  
(2) Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME COLOR  
ON: Ready for digital data transmission or the circuit is busy.  
OFF: Fixed path is not connected.  
BL0  
Red  
Flash (60IPM): Make-busy state or the system data for this card is not as-  
signed.  
Flash (120IPM): Fixed path is connected.  
ON: Loop Back 1 is set.  
OFF: Normally operating.  
LB01  
LB02  
RSC0  
SDT0  
RDR0  
CDI0  
Red  
Red  
ON: Loop Back 2 is set.  
OFF: Normally operating.  
No. 0 Circuit  
ON: RTS/C signal ON.  
OFF: RTS/C signal OFF.  
Green  
Green  
Green  
Green  
ON: TXD/T signal is “0”.  
OFF: TXD/T signal is “1”.  
ON: RXD/R signal is “0”.  
OFF: RXD/R signal is “1”.  
ON: DCD/I signal ON.  
OFF: DCD/I signal OFF.  
ON: Ready for digital data transmission or the circuit is busy.  
OFF: Fixed path is not connected.  
BL1  
Red  
Flash (60IPM): Make-busy state or the system data for this card is not as-  
signed.  
Flash (120IPM): Fixed path is connected.  
ON: Loop Back 1 is set.  
OFF: Normally operating.  
LB11  
LB12  
RSC1  
SDT1  
RDR1  
CDI1  
Red  
Red  
ON: Loop Back 2 is set.  
OFF: Normally operating.  
No. 1 Circuit  
ON: RTS/C signal ON.  
OFF: RTS/C signal OFF.  
Green  
Green  
Green  
Green  
ON: TXD/T signal is “0”.  
OFF: TXD/T signal is “1”.  
ON: RXD/R signal is “0”.  
OFF: RXD/R signal is “1”.  
ON: DCD/I signal ON.  
OFF: DCD/I signal OFF.  
ND-45504 (E)  
CHAPTER 4  
Page 119  
Revision 2.0  
PN-2DPCB (DPC)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NUMBER POSITION  
SETTING  
SWITCH NAME  
FUNCTION  
Loop Back 1 ON  
CHECK  
SW1  
(Piano Key SW)  
ON  
1
Loop Back 1 OFF  
OFF  
No. 0  
Circuit  
ON  
Loop Back 2 ON  
OFF  
2
Loop Back 2 OFF  
OFF  
4
3
2
1
ON  
Loop Back 1 ON  
3
Loop Back 1 OFF  
OFF  
No. 1  
Circuit  
ON  
Loop Back 2 ON  
ON  
4
Loop Back 2 OFF  
OFF  
SW0 (Dip SW)  
ON  
Forcibly turning the DTR signal to ON  
The DTR signal from DTE goes through the card  
Forcibly turning the RTS/C signal to ON  
The RTS/C signal from DTE goes through the card  
Not used  
1
OFF  
1 2 3 4 5 6 7 8  
ON  
ON  
2
No. 0  
Circuit  
OFF  
3
4
OFF  
ON  
V.11 (X.21) interface  
OFF  
ON  
V.24/V.28 (RS-232C) interface  
Forcibly turning the DTR signal to ON  
The DTR signal from DTE goes through the card  
Forcibly turning the RTS/C signal to ON  
The RTS/C signal from DTE goes through the card  
Not used  
5
OFF  
ON  
6
7
8
No. 1  
Circuit  
OFF  
OFF  
ON  
V.11 (X.21) interface  
OFF  
V.24/V.28 (RS-232C) interface  
The figure in the SWITCH NAME column and the position in  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure  
and , the setting of the switch varies with the system concerned.  
in the SETTING POSITION col-  
Note: When the power is on, disconnect the cables before unplugging the circuit card, and connect the cables af-  
ter plugging the circuit card.  
CHAPTER 4  
Page 120  
ND-45504 (E)  
Revision 2.0  
PN-2ILCA (ILC)  
PN-2ILCA (ILC)  
1. Locations of Lamps, Switches, and Connectors  
ACT1  
PAL1  
LPB1  
B21  
B11  
ACT0  
PAL0  
LPB0  
B20  
B10  
SW1  
SW0  
PN-2ILCA (ILC) Card  
ND-45504 (E)  
CHAPTER 4  
Page 121  
Revision 2.0  
PN-2ILCA (ILC)  
(2) Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
ON: Normally operating.  
OFF: Not operating.  
ACT1  
Green  
ON: Line is short-circuiting.  
OFF: Normally operating.  
PAL1  
LPB1  
B21  
Red  
Red  
No. 1 Circuit OFF: Not used.  
ON: B2 channel is in use.  
OFF: B2 channel is idle.  
Green  
ON: B1 channel is in use.  
OFF: B1 channel is idle.  
B11  
Green  
Green  
ON: Normally operating.  
OFF: Not operating.  
ACT0  
ON: Line is short-circuiting.  
OFF: Normally operating.  
PAL0  
LPB0  
B20  
Red  
Red  
No. 0 Circuit OFF: Not used.  
ON: B2 channel is in use.  
OFF: B2 channel is idle.  
Green  
ON: B1 channel is in use.  
OFF: B1 channel is idle.  
B10  
Green  
CHAPTER 4  
Page 122  
ND-45504 (E)  
Revision 2.0  
PN-2ILCA (ILC)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
SW1  
(Piano Key SW)  
Always set to OFF  
Always set to OFF  
Always set to OFF  
Always set to OFF  
1
2
3
OFF  
OFF  
OFF  
OFF  
4
3
2
1
4
1
2
3
4
OFF  
ON  
SW0  
(Piano Key SW)  
No. 0 Circuit Terminating register is provided.  
ON  
OFF  
ON  
(Receiving)  
Terminating register is not provided.  
OFF  
No. 0 Circuit Terminating register is provided.  
4
3
2
1
(Sending)  
OFF  
ON  
Terminating register is not provided.  
No. 1 Circuit Terminating register is provided.  
(Receiving)  
OFF  
ON  
Terminating register is not provided.  
ON  
No. 1 Circuit Terminating register is provided.  
(Sending)  
OFF  
Terminating register is not provided.  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
ND-45504 (E)  
CHAPTER 4  
Page 123  
Revision 2.0  
PN-4LCD/4LCD-A (LC)  
PN-4LCD/4LCD-A (LC)  
1. Locations of Lamps, Switches and Connectors  
BL3  
BL2  
BL1  
BL0  
PN-4LCD/4LCD-A (LC) Card  
2. Lamp Indications  
Lamp Indications  
FUNCTION  
LAMP NAME  
COLOR  
• Remains lit when the corresponding circuit is in use.  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
BL0-3  
Red  
3. Switch Settings  
This card has no switches.  
CHAPTER 4  
ND-45504 (E)  
Page 124  
Revision 2.0  
PN-4LCJ (LC)  
PN-4LCJ (LC)  
1. Locations of Lamps, Switches and Connectors  
BL3  
BL2  
BL1  
BL0  
PN-4LCJ (LC) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the corresponding circuit is in use.  
BL0 - 3  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 125  
Revision 2.0  
PN-M03 (M03)  
PN-M03 (M03)  
1. Locations of Lamps, Switches and Connectors  
OPRS  
OPER  
SW0  
OPSD  
OPE  
RS  
SD  
RD  
CD  
ER  
DR  
CS  
SELX21  
X21  
SELCN0  
CN0  
JP1B  
JP1A  
V35  
PN-M03 (M03) Card  
CHAPTER 4  
Page 126  
ND-45504 (E)  
Revision 2.0  
PN-M03 (M03)  
(2) Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
ON: This card is normally connected to the PN-2DPCB.  
OFF: This card is abnormally connected to the PN-2DPCB.  
OPE  
Green  
Green  
Green  
Green  
Green  
Green  
Green  
Green  
ON: RTS signal is ON.  
OFF: RTS signal is OFF.  
RS  
SD  
RD  
CD  
ER  
DR  
CS  
ON: TXD signal is “0” (Space condition).  
OFF: TXD signal is “1” (Mark condition).  
ON: RXD signal is “0” (Space condition).  
OFF: RXD signal is “1” (Mark condition).  
ON: DCD signal is ON.  
OFF: DCD signal is OFF.  
ON: DTR signal is ON.  
OFF: DTR signal is OFF.  
ON: DSR signal is ON.  
OFF: DSR signal is OFF.  
ON: CTS signal is ON.  
OFF: CTS signal is OFF.  
ON: Connecting to the PN-2DPCB is available.  
OFF: Connecting to the PN-2DPCB is not available.  
SELX21  
SELCN0  
Green  
Green  
Not used.  
ND-45504 (E)  
CHAPTER 4  
Page 127  
Revision 2.0  
PN-M03 (M03)  
(3) Switch Settings  
Switch Settings  
SWITCH  
NAME  
SWITCH  
NUMBER POSITION  
SETTING  
FUNCTION  
CHECK  
SW0 (Dip SW)  
Always set to OFF.  
Not used.  
1
2
OFF  
OFF  
2
1
ON  
JP1A (Jumper pin)  
TXC(2) signal is sent out.  
Right  
Left  
TXC(2) signal is inputted.  
Note  
JP1B (Jumper pin)  
TXC(2) signal is sent out.  
Right  
Left  
TXC(2) signal is inputted.  
Note  
OPSD (Jumper pin)  
Set the function of extending distance for TXD signal.  
Right  
Left  
Cancel the function of extending distance for TXD sig-  
nal.  
OPRS (Jumper pin)  
OPER (Jumper pin)  
Set the function of extending distance for RTS signal.  
Right  
Left  
Cancel the function of extending distance for RTS sig-  
nal.  
Set the function of extending distance for DTR signal.  
Right  
Left  
Cancel the function of extending distance for DTR sig-  
nal.  
Note: The JP1A and JP1B must be set to the same position each other.  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
CHAPTER 4  
ND-45504 (E)  
Page 128  
Revision 2.0  
PN-2ODTA (ODT)  
PN-2ODTA (ODT)  
1. Locations of Lamps, Switches and Connectors  
BL1  
BL0  
CN1  
PN-2ODTA (ODT) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
• Remains lit when the corresponding circuit is in use.  
BL0, 1  
Red  
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system  
data for this card is not assigned.  
3. Switch Settings  
This card has no switches.  
ND-45504 (E)  
CHAPTER 4  
Page 129  
Revision 2.0  
PN-8RSTA (PBR)  
PN-8RSTA (PBR)  
1. Locations of Lamps, Switches and Connectors  
PN-8RSTA (PBR) Card  
2. Lamp Indications  
This card has no indicator lamps.  
3. Switch Settings  
This card has no switches.  
CHAPTER 4  
ND-45504 (E)  
Page 130  
Revision 2.0  
PN-TNTA (TNT)  
PN-TNTA (TNT)  
1. Location of Lamps, Switches and Connectors  
SW  
JACK1  
JACK0  
PN-TNTA (TNT) Card  
2. Lamp Indications  
This card has no lamps.  
ND-45504 (E)  
CHAPTER 4  
Page 131  
Revision 2.0  
PN-TNTA (TNT)  
3. Switch Settings  
Switch Settings  
SWITCH  
NUMBER  
SETTING  
POSITION  
SWITCH NAME  
SW  
FUNCTION  
CHECK  
Volume adjustment for No. 0 circuit  
(Piano Key SW)  
SWITCH NUMBER  
VOLUME  
OFF  
1
2
1, 2  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
–10 dB  
–7 dB  
–4 dB  
–1 dB  
4
3
2
1
ON  
ON  
Volume adjustment for No. 1 circuit  
SWITCH NUMBER  
VOLUME  
3
4
3, 4  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
–10 dB  
–7 dB  
–4 dB  
–1 dB  
ON  
CHAPTER 4  
Page 132  
ND-45504 (E)  
Revision 2.0  
PN-2CSIA (CSI)  
PN-2CSIA (CSI)  
1. Locations of Lamps, Swtiches, and Connectors.  
OPE  
LB  
B13  
B12  
B11  
B10  
B03  
B02  
B01  
B00  
DL1  
DL0  
PN-2CSIA (CSI) Card  
2. Lamp Indications  
Lamp Indications  
LAMP NAME  
COLOR  
FUNCTION  
OPE  
LB  
Green  
Red  
Lights when the corresponding circuit is in use.  
Lights when a loop-back is in progress.  
Not used (Flash [60IPM])  
B13  
Red  
B channel status  
ON : B2 channel of the No. 1 circuit is in use.  
OFF : B2 channel of the No. 1 circuit is in idle.  
Flash (60 IPM) : ZT is not connected to the No. 1 circuit.  
ZT is in make-busy status.  
B12  
B11  
Red  
Red  
B channel status  
ON : B1 channel of the No. 1 circuit is in use.  
OFF : B1 channel of the No. 1 circuit is in idle.  
Flash (60 IPM) : ZT is not connected to the No. 1 circuit.  
ZT is in make-busy status.  
ND-45504 (E)  
CHAPTER 4  
Page 133  
Revision 2.0  
PN-2CSIA (CSI)  
LAMP NAME  
Lamp Indications  
COLOR  
FUNCTION  
B channel status  
ON : B0 channel of the No. 1 circuit is in use.  
OFF : B0 channel of the No. 1 circuit is in idle.  
Flash (60 IPM) : ZT is not connected to the No. 1 circuit.  
ZT is in make-busy status.  
B10  
B03  
B02  
Red  
Red  
Red  
Not used (Flash[60 IMP])  
B channel status  
ON : B2 channel of the No. 0 circuit is in use.  
OFF : B2 channel of the No. 0 circuit is in idle.  
Flash (60 IPM) : ZT is not connected to the No. 0 circuit.  
ZT is in make-busy status.  
B channel status  
ON : B1 channel of the No. 0 circuit is in use.  
OFF : B1 channel of the No. 0 circuit is in idle.  
Flash (60 IPM) : ZT is not connected to the No. 0 circuit.  
ZT is in make-busy status.  
B01  
B00  
Red  
Red  
B channel status  
ON : B0 channel of the No. 0 circuit is in use.  
OFF : B0 channel of the No. 0 circuit is in idle.  
Flash (60 IPM) : ZT is not connected to the No. 0 circuit.  
ZT is in make-busy status.  
3. Switch Settings  
Switch Settings  
SWITCH  
NUMBER POSITION  
SETTING  
SWITCH NAME  
FUNCTION  
CHECK  
DL0 (Rotary SW)  
For normal operation  
0
0 ~ F  
Not used  
1 ~ F  
Note  
DL1 (Rotary SW)  
For normal operation  
0
0 ~ F  
Not used  
1 ~ F  
Note  
The figure in the SWITCH NAME column and the position in  
in the SETTING POSITION col-  
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and  
, the setting of the switch varies with the system concerned.  
Note: Set the groove on the switch knob to the intended switch position.  
CHAPTER 4  
Page 134  
ND-45504 (E)  
Revision 2.0  

Insignia IS CM100751 User Manual
Juniper Networks Secure Services Gateway SSG 20 User Manual
JVC KS RF50 User Manual
Moffat Blue Seal G518B LS User Manual
Moffat E27 User Manual
Philips 29PT785C User Manual
Philips DVP5150X User Manual
Philips HDR3700 User Manual
Philips Magnavox DVD850AT User Manual
Philips MDV460 User Manual