NEC Electronics America Computer Hardware 2000 IVS User Manual |
ND-45504 (E)
ISSUE 2
PART OF STOCK # 151900
®
Circuit Card Manual
DECEMBER, 1997
NEC America, Inc.
ADD. No.
ADD. No.
PAGE No.
PAGE No.
001 002 003 004 005 006 007 008
001 002 003 004 005 006 007 008
i
2.2
2.1
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
65-1
65-2
65-3
65-4
66
67
68
2.2
2.2
ii
iii
iv
1
2.2
2
2.1
2.2
2.2
3
2.2
2.1
4
5
2.1
6
7
8
9
2.2
2.2
2.2
2.2
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
2.1
2.1
2.2
2.1
2.1
2.1
2.1
2.1
2.2
2.1
2.2
2.2
2.2
2.1
ADDENDUM-001
JULY, 1998
ADDENDUM-002
OCTOBER, 1998
ADDENDUM-006
ADDENDUM-003
ADDENDUM-004
ADDENDUM-008
DATE
DATE
DATE
DATE
DATE
DATE
DATE
DATE
ADDENDUM-005
ADDENDUM-007
NEAX2000 IVS
Circuit Card Manual
Addendum Revision Sheet 1/2
ND-45504 (E) ISSUE 2
ADD. No.
ADD. No.
PAGE No.
PAGE No.
001 002 003 004 005 006 007 008
001 002 003 004 005 006 007 008
68-1
68-2
68-3
68-4
69
2.1
2.1
2.1
2.1
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
70
2.1
2.1
71
72
73
74
75
76
77
78
78-1
78-2
78-3
78-4
78-5
78-6
79
2.1
2.1
2.1
2.1
2.1
2.1
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
ADDENDUM-001
JULY, 1998
ADDENDUM-005
ADDENDUM-002
OCTOBER, 1998
ADDENDUM-006
ADDENDUM-003
ADDENDUM-004
ADDENDUM-008
DATE
DATE
DATE
DATE
DATE
DATE
ADDENDUM-007
DATE
DATE
NEAX2000 IVS
Circuit Card Manual
Addendum Revision Sheet 2/2
ND-45504 (E) ISSUE 2
ND-45504 (E)
ISSUE 2
DECEMBER, 1997
NEAX2000 IVS
Circuit Card Manual
TABLE OF CONTENTS
Page
LIST OF FIGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv
CHAPTER 1
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1. PURPOSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. OUTLINE OF THE MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
CHAPTER 2
FUNCTIONAL OUTLINE OF CIRCUIT CARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1. CONTROL CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. APPLICATION CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. LINE/TRUNK CIRCUIT CARDS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CHAPTER 3
CIRCUIT CARD INSTALLATION CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1. CIRCUIT CARD MOUNTING SLOTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2. INSTALLATION CONDITIONS FOR CONTROL CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.1
2.2
2.3
2.4
2.5
2.6
PN-CP00/PN-CP00-B/PN-CP00-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PN-CP01 (FP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PN-CP02/PN-CP02-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
PN-BS00-A/PN-BS00-B (BS00), PN-BS01-A/PN-BS01-B (BS01) . . . . . . . . . . . . . . . . . . . . . . . 13
PN-PW00 (EXTPWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
PZ-PW86 (PWR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3. INSTALLATION CONDITIONS FOR APPLICATION CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . 14
4. INSTALLATION CONDITIONS FOR LINE/TRUNK CIRCUIT CARDS . . . . . . . . . . . . . . . . . . . . . . . . . . 16
CHAPTER 4
LAMP INDICATIONS AND SWITCH SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1. PRECAUTION IN HANDLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
2. LAMP INDICATIONS AND SWITCH SETTINGS OF CONTROL CIRCUIT CARDS. . . . . . . . . . . . . . . . 21
PN-BS00-A/PN-BS00-B (BS00). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
PN-BS01-A (BS01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
PN-BS01-B (BS01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
PN-CP00 (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
PN-CP00-B/PN-CP00-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
PN-CP03/PN-CP03-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
PN-CP01 (FP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
PN-CP02/PN-CP02-C (MP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
PN-PW00 (EXTPWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
PZ-PW86 (PWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
PZ-PW86-A (PWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
PZ-PW86 (C) (PWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
PZ-PW86 (D) (PWR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
ND-45504 (E)
Addendum-002
OCTOBER, 1998
TABLE OF CONTENTS
Page i
Revision 2.2
Page
3. LAMP INDICATIONS AND SWITCH SETTINGS OF APPLICATION CIRCUIT CARDS . . . . . . . . . . . . . 52
PN-AP00-A (AP00) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
PN-AP01 (AP01). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
PN-BRTA (BRI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
PN-2BRTC (BRI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-1
PN-CC00 (ETHER) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
PN-CC01 (ETHER) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68-1
PN-CK00 (PLO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
PN-24DTA (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
PN-24DTA-A (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
PN-30DTC/30DTC-A (DTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78-1
PN-ME00 (EXTMEM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
PN-4RSTB (MFR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
PN-4RSTC (CIR). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
PN-SC00 (CCH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
PN-SC01 (DCH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
PN-SC02 (ICH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
PN-SC03 (ICH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
PN-SC03 (CSH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
4. LAMP INDICATIONS AND SWITCH SETTINGS OF LINE/TRUNK CIRCUIT CARDS . . . . . . . . . . . . . 100
PN-2AMPA (AMP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
PN-AUCA (AUC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
PN-CFTA (CFT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
PN-4COTB (COT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
PN-4COTG (COT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
PN-2DATA (DAT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
PN-DK00 (DK). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
PN-4DITB (DIT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
PN-2DLCB (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
PN-2DLCC (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
PN-2DLCN (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
PN-4DLCA (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
PN-4DLCD (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
PN-4DLCF (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
PN-4DLCM (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
PN-4DLCQ (DLC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
PN-2DPCB (DPC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
PN-2ILCA (ILC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
PN-4LCD/4LCD-A (LC). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
PN-4LCJ (LC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
PN-M03 (M03). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
PN-2ODTA (ODT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
PN-8RSTA (PBR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
PN-TNTA (TNT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
PN-2CSIA (CSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
TABLE OF CONTENTS
Page ii
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
LIST OF FIGURES
Figure Title
Page
3-1
3-2
3-3
3-4
3-5
3-6
4-1
4-2
Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
MP/FP Card Mounting Slots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
MP/FP Card Mounting Slots for Back up MP System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
BS00/BS01 Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Application Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Line/Trunk Circuit Card Mounting Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Static Electricity Precautions (1 of 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Circuit Card Handling Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
ND-45504 (E)
LIST OF FIGURES
Page iii
Revision 2.0
LIST OF TABLES
Table
Title
Page
2-1
2-2
2-3
4-1
4-2
4-3
Functional Outline of Control Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Functional Outline of Application Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Functional Outline of Line/Trunk Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table of Control Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table of Application Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table of Line /Trunk Circuit Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
LIST OF TABLES
Page iv
ND-45504 (E)
Revision 2.0
CHAPTER 1
1. PURPOSE
INTRODUCTION
For installers and maintenance technicians of the NEAX2000 IVS (PBX), this manual explains the functional
outline and installation conditions of the circuit cards, and explains the meaning of each indicator lamp (LED)
and the switch settings on the circuit cards.
2. OUTLINE OF THE MANUAL
This manual consists of four chapters. The contents of Chapter 2 through 4 are as outlined below.
•
•
•
Chapter 2: Functional Outline of Circuit Cards
This chapter outlines various circuit cards used in the system by means of tables.
Chapter 3: Circuit Card Accommodating Conditions
This chapter explains the conditions for installing various circuit cards used in the system.
Chapter 4: Lamp Indications and Switch Settings
This chapter explains the meaning of lamp indications and the switch settings of various circuit cards used
in the system.
Each switch setting table provided in Chapter 4 has a “CHECK” column. Make necessary entries in the CHECK
column during and/or after system installation and maintenance. After the result of switch setting has been
checked, use each table as a reference for subsequent system maintenance and operations.
ND-45504 (E)
CHAPTER 1
Page 1
Revision 2.0
This page is for your notes.
CHAPTER 1
Page 2
ND-45504 (E)
Revision 2.0
CHAPTER 2
FUNCTIONAL OUTLINE OF CIRCUIT CARDS
This chapter explains the functional outline of various circuit cards used in the NEAX2000 IVS. Explanations are
given in alphabetical order of the circuit card names for each kind (Control, Application, and Line/Trunk) of circuit
cards.
1. CONTROL CIRCUIT CARDS
Table 2-1 shows the functional outline of each control circuit card.
Table 2-1 Functional Outline of Control Circuit Cards
FUNCTIONAL
CARD NAME
FUNCTIONAL OUTLINE
NAME
Bus interface card for PIM0.
This card functions as a driver/receiver of various signals, adjusts gate delay tim-
ing and cable delay timing, monitors the I/O Bus and PCM Bus, and controls the
power supply.
PN-BS00-A
/PN-BS00-B
BS00
When the system consists of more than one PIM, this card is mounted in PIM0.
Only one per system is used.
Bus interface card for PIM1 through PIM7.
This card functions as a driver/receiver of various signals, adjusts gate delay tim-
ing and cable delay timing, monitors the I/O Bus and PCM Bus, and controls the
power supply.
When the system consists of more than one PIM, one each of this card is mounted
respectively in PIM1 through PIM7.
PN-BS01-A
/PN-BS01-B
BS01
MP
Main Processor card.
PN-CP00
/PN-CP00-B
/PN-CP00-C
This card is equipped with Memory, TDSW (1024CH × 1024CH), 16-Line CFT,
PB Sender, Clock, PLO (slave mode 2 ports), RS-232C Ports (2 ports), Modem
for remote maintenance, and Internal Music-On-Hold tone source.
One card per system.
Main Processor card.
This card is equipped with Memory, TDSW (1024CH × 1024CH), 16-Line CFT,
PB Sender, PB Receiver, Clock, PLO (slave mode 2 ports), RS-232C Ports (2
ports) for MAT/Built-in SMDR, Modem for remote maintenance, Internal/Exter-
nal Music-On-Hold tone source.
PN-CP03
/PN-CP03-C
MP
One card per system (This card can be used only in 1 or 2 PIM system).
Firmware Processor card.
This card is equipped with Line/Trunk Interface and Memory. When the system
consists of more than one PIM, one each of this card is mounted respectively in
PIM0, PIM2, PIM4 and PIM6.
PN-CP01
FP
MP
Main Processor card for Back Up MP System only.
This card is equipped with Memory, TDSW (1024CH × 1024CH), 16-Line CFT,
PB Sender, Clock, PLO (slave mode 2 ports), RS-232C Ports (2 ports), Modem
for remote maintenance, and Music-On-Hold tone source. Two cards per Back up
MP System.
PN-CP02
/PN-CP02-C
Power Supply card for SN716 Desk Console.
This card provides –48 V DC power for one SN716 Desk Console, and is mount-
ed in the LT/AP slot of PIM. Max. 3 PN-PW00 cards per PIM and max. 4 cards
per 4 PIM.
PN-PW00
PW00
ND-45504 (E)
Addendum-002
OCTOBER, 1998
CHAPTER 2
Page 3
Revision 2.2
Table 2-1 Functional Outline of Control Circuit Cards (Continued)
FUNCTIONAL
FUNCTIONAL OUTLINE
NAME
CARD NAME
Main power supply card.
PZ-PW86/
PZ-PW86-A
Input:
AC100 V/200 V (50 Hz/60 Hz)
PWR
PWR
PWR
Output: –27 V (8 A), +5 V (8.5 A), CR (30 mA)
One card per PIM.
Main power supply card.
Input:
Output: –27 V (4.5 A), +5 V (7.5 A), CR (30 mA), +80 V (110 mA)
One card per PIM.
AC100 V/200 V (50 Hz/60Hz)
PZ-PW86(C)
PZ-PW86(D)
Main power supply card.
Input:
Output: –27 V (4.5 A), +5 V (7.5 A), CR (30 mA), +80 V (110 mA)
One card per PIM.
AC100 V/200 V (50 Hz/60 Hz)
2. APPLICATION CIRCUIT CARDS
Table 2-2 shows the functional outline of each application circuit card.
Table 2-2 Functional Outline of Application Circuit Cards
FUNCTIONAL
CARD NAME
FUNCTIONAL OUTLINE
NAME
Application Processor card.
This card is equipped with four RS-232C ports, and is used for SMDR, H/M Print-
er, PMS functions and MCI.
PN-AP00-A
AP00
One card per system.
Application Processor card.
This card is equipped with one RS-232C port and one Ethernet interface port, and
PN-AP01
AP01
is used for OAI function. Also, this card is used to expand authorization code and
ACD.
One card per system.
Basic Rate (2B+D) Interface Trunk card. (S/T Interface)
This card has one circuit of Basic Rate interface and provides one 2-channel PCM
digital line.
PN-BRTA
BRI
BRI
This card is used for BRI trunks from the Telco to the PBX.
Basic Rate (2B+D) Interface Trunk card.
This card has two circuits of Basic Rate interface and provides two 2-channel
PCM digital lines.
PN-2BRTC
This card is used for BRI trunks from the Telco to the PBX.
Memory Expansion card.
This card is used with PN-AP00-A card for providing expansion memory.
This card can be equipped with a SRAM card (1MB) as extra SMDR data memo-
ry.
PN-ME00
PN-CC00
EXTMEM
ETHER
Ethernet Control card.
This card is used with the PN-AP01 card to accommodate the Ethernet, transmit-
ting/receiving a signal of TCP/IP protocol.
CHAPTER 2
Page 4
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
Table 2-2 Functional Outline of Application Circuit Cards (Continued)
FUNCTIONAL
FUNCTIONAL OUTLINE
NAME
CARD NAME
Ethernet Control card.
This card is used with the PN-AP01 card to accommodate the Ethernet, transmit-
ting/receiving a signal of TCP/IP protocol.
10 BASE-T twisted pair cable can be connected directly to this card.
PN-CC01
ETHER
PLO
Phase Locked Oscillator card.
This card is a phase locked oscillator for providing a synchronized clock signal
with the network.
PN-CK00
This card is used when the PBX is a master office or when the PBX requires two
clock supply routes and those frequencies differ.
PN-24DTA
/PN-24DTA-A
Digital Trunk Interface (23B+D, 1.5 Mbps) card.
This card accommodates one 24-channel PCM digital lines.
DTI
DTI
PN-30DTC
/PN-30DTC-A
Digital Trunk Interface (2 Mbps) card.
This card accommodates one 30-channel PCM digital line.
4-line MF Receiver Trunk card.
PN-4RSTB
PN-4RSTC
PN-SC00
MFR
CIR
This card is used for MF Signaling on Digital DID trunks. A maximum of four
cards can be provided per one system, including the PN-4RSTC card.
4-line CALLER ID Receiver Trunk card.
This card is used for CALLER ID (CLASS SM) on analog trunks. A maximum of
four cards can be provided per one system, including the PN-4RSTB card.
Common Channel Handler card.
This card transmits/receives signals on the common signaling channel of No. 7
CCIS.
CCH
DCH
D-channel Handler card.
This card transmits/receives signals on the D channel of ISDN Primary Rate
(23B+D).
PN-SC01
ISDN-channel Handler card.
This card provides the D channel signaling interface and controls an ILC (Layer 2
and 3).
There are 2 types of the ICH card.
PN-SC02 is the 2-channel ICH card.
PN-SC03 is the 8-channel ICH card.
PN-SC02
/PN-SC03
ICH
Zone Transceiver Channel Handler card.
PN-SC03
CSH
This card provides 8 D-channel signaling interface through the PN-2CSIA to the
Zone Transceiver for the Wireless Communication System.
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 2
Page 5
Revision 2.1
3. LINE/TRUNK CIRCUIT CARDS
Table 2-3 shows the functional outline of each line/trunk circuit card.
Table 2-3 Functional Outline of Line/Trunk Circuit Cards
FUNCTIONAL
CARD NAME
FUNCTIONAL OUTLINE
NAME
2-line Amplifier Trunk card.
PN-2AMPA
AMP
This card is equipped with the functions of Echo Canceller (EC), Automatic Gain
Controller (AGC) and Tone Disabler (TD).
2-line Long-Line circuit card provided with the Power Failure Transfer (PFT)
function.
Line resistance in the case of a long-line circuit: Max. 2500 ohms (inclusive of
the internal resistance of the distant office equipment)
This card is internally equipped with a –48 V DC On-Board Power Supply.
This card can also be used as a 2-line Direct Inward Dialling trunk card.
PN-AUCA
PN-CFTA
AUC
CFT
Conference Trunk card
Use of one card: Can control a conference of up to six participants.
Use of two cards:Can control a conference of up to ten participants.
4-line Central Office Trunk card (Ground Start/Loop Start trunk) equipped with
the functions for loop detection, sending/detecting ground on Ring/Tip wire.
PN-4COTB
PN-4COTG
PN-2DATA
COT
COT
DAT
4-line Central Office Trunk card (Loop Start trunk) equipped with the functions
for loop detection, receiving/sending the CALLER ID (CLASS SM) signal.
2-line Digital Announcement Trunk card.
Duration: Max. 60 seconds.
Circuit card for External Relay Control/External Key Scan.
This card is provided with eight circuits, and can provide the above-mentioned
control functions on a per circuit basis.
PN-DK00
PN-4DITB
DK
4-line Direct In Dialing Trunk card.
This card is equipped with the function for loop detection, sending reverse signal
and PB to DP signal conversion.
DIT
This card is internally equipped with –48 V DC On-Board Power supply.
term
2-line Digital Line Circuit card for D
Series E/Series III/DSS Console.
[–48V Version, 2-wire type, line length: max. 850 m (2789 ft.)]
This card is equipped with quick diagnostics to detect short line conditions and
the normality (Synchronous/Asynchronous) of the terminal.
This card is internally equipped with a –48 V DC On-Board Power Supply.
term
PN-2DLCB
PN-2DLCC
PN-2DLCN
DLC
DLC
DLC
2-line Digital Line Circuit card for D
Series II/SN610 Attendant Console.
[–48 V Version, 4-wire type, line length: max. 1200 m (3940 ft.)]
This card is equipped with quick diagnostics to detect short line conditions and
the normality (Synchronous/Asynchronous) of the terminal.
This card is internally equipped with –48 V On-Board Power Supply.
term
2-line Digital Line Circuit card for D
Series E/Series III/DSS Console.
[–48 V Version, 2-wire type, line length: max. 850 m (2789 ft.)]
This card is equipped with quick diagnostics to detect short line conditions
and the normality (Synchronous/Asynchronous) of the terminal.
This card is internally equipped with a –48 V DC On-Board Power Supply.
CHAPTER 2
Page 6
ND-45504 (E)
Revision 2.0
Table 2-3 Functional Outline of Line/Trunk Circuit Cards (Continued)
FUNCTIONAL
FUNCTIONAL OUTLINE
NAME
CARD NAME
term
4-line Digital Line Circuit card for D
Series E/Series III/ElectraPro/DSS Con-
sole.
PN-4DLCA
DLC
[–27 V Version, 2-wire type, line length: max. 200 m (656 ft.)]
This card is equipped with quick diagnostics to detect short line conditions and
the normality (Synchronous/Asynchronous) of the terminal.
4-line Digital Line Circuit card exclusively used for Dterm Series E/Series III.
[-27 V Version, 2-wire type, line length: max. 200 m (656 ft.)]
This card is equippedwith quick diagnostics to detect short line conditions and the
normality (Synchronous/Asynchronous) of the terminal.
PN-4DLCD
PN-4DLCF
DLC
DLC
4-line Digital Line Circuit card for Dterm Series II/SN610 Attendant Console
[-27 V Version, 4-wire type, line length: max. 300 m (984.3 ft.)].
This card is equipped with quick diagnostics to detect short line conditions.
4-line Digital Line Circuit card for Dterm Series E/Series III/ElectraPro/DSS Con-
sole.
PN-4DLCM
PN-4DLCQ
DLC
DLC
[–27 V Version, 2-wire type, line length: max. 200 m (656 ft.)]
This card is equipped with quick diagnostics to detect short line conditions and
the normality (Synchronous/Asynchronous) of the terminal.
4-line Digital Line Circuit card exclusively used for Dterm Series E/Series III.
[–27 V Version, 2-wire type, line length: max. 200 m (656 ft.)]
This card is equipped with quick diagnostics to detect short line conditions and
the normality (Synchronous/Asynchronous) of the terminal.
2-line Data Port Controller card.
This card is used for the intra-office or inter-office digital data transmission on
fixed path connection.
And this card can accommodate a maximum of two DTE with V.11 (X.21) inter-
face or V.24/V.28 (RS-232C) interface.
PN-2DPCB
PN-2ILCA
DPC
ILC
2-line ISDN Line Circuit card.
This card provides a physical interface to ISDN Terminals.
4-line Analog Line Circuit card for single line telephones.
This card is equipped with the function for controlling Message Waiting Lamp.
Loop resistance: Max. 600 ohms.
PN-4LCD
LC
LC
This card is equipped with quick diagnostics to detect short and open line condi-
tions.
This card is internally equipped with a +80 V DC-DC Power Supply circuit and
a relay for momentary open (only in No.3 circuit).
4-line Analog Line Circuit card for single line telephones.
This card is equipped with momentary open function.
This card is equipped with the function for controlling Message Waiting Lamp.
Loop resistance: Max. 600 ohms.
PN-4LCD-A
This card is equipped with quick diagnostics to detect short and open line condi-
tions.
This card is internally equipped with a +80 V DC-DC Power Supply circuit.
ND-45504 (E)
CHAPTER 2
Page 7
Revision 2.0
Table 2-3 Functional Outline of Line/Trunk Circuit Cards (Continued)
FUNCTIONAL
FUNCTIONAL OUTLINE
NAME
CARD NAME
4-line Analog Line Circuit card for single line telephones.
This card provides 4 circuits with Disconnect Supervision.
PN-4LCJ
PN-M03
LC
Loop resistance: Max. 600 ohms.
This card is equipped with quick diagnostics to detect short and open line condi-
tions.
V.35 DTE interface card.
This card is used together with the PN-2DPCB card to provide the V.35 interface.
M03
ODT
2-line OD Trunk card.
This card can be used as either a 2-wire E&M trunk or a 4-wire E&M trunk, and
is internally equipped with a –48 V DC On-Board Power Supply.
Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in
one card.
PN-2ODTA
8-line PB Receiver card.
This card can be used for a PB station line, DID or tie line.
PN-8RSTA
PN-TNTA
PBR
TNT
2-line Tone/Music Source interface card.
This card is used for BGM or Music on Hold, and is equipped with two interface
for an external tone/music source.
2-line Zone Transceiver Interface card.
The CSI is used to interface with the Wireless Communication System to the
Zone Transceiver, based on ISDN S-interface.
Each CSI occupies 7 time slots.
PN-2CSIA
CSI
CHAPTER 2
Page 8
ND-45504 (E)
Revision 2.0
CHAPTER 3
CIRCUIT CARD INSTALLATION CONDITIONS
This chapter explains the conditions for installing various kinds of circuit cards used in the PBX.
1. CIRCUIT CARD MOUNTING SLOTS
Figure 3-1 below shows circuit card mounting slots allocated in the PIM based on circuit card type.
PIM0 - 7
PWR
*1
*2 *3 *4
BUILT-IN BATTERY
LT00 - LT15
AP0 - AP8
MP
FP
BUS
:
:
:
:
:
:
Line/trunk circuit card mounting slots
Application circuit card mounting slots
PN-CP00/PN-CP00-B/PN-CP00-C mounting slot
PN-CP01 mounting slots
PN-BS00-A/PN-BS00-B, PN-BS01-A/PN-BS01-B mounting slot
PZ-PW86 mounting slot
PWR
*1 Either line/trunk circuit cards or application circuit cards can be mounted in these slots.
*2 PN-CP01 or an application circuit card is to be mounted in this slot according to the system
configuration.
*3 PN-CP00/PN-CP00-B/PN-CP00-C, PN-CP01 or an application circuit card is to be
mounted in this slot according to the system configuration.
*4 PN-BS00-A/PN-BS00-B, PN-BS01-A/PN-BS01-B or an application circuit card is to be
mounted in this slot according to the system configuration.
Figure 3-1 Circuit Card Mounting Slots
ND-45504 (E)
Addendum-002
OCTOBER, 1998
CHAPTER 3
Page 9
Revision 2.2
PIM(H)0
PWR
*1
*2
*3
BUILT-IN BATTERY
LT00 - LT15
:
:
:
:
:
:
Line/trunk circuit card mounting slots
Application circuit card mounting slots
PN-CP02/PN-CP02-C mounting slot
PN-CP01 mounting slots
PN-BS00-A/PN-BS00-B, PN-BS01-A/PN-BS01-B mounting slot
PZ-PW86/PZ-PW86-A/PZ-PW86 (C)/(D) mounting slot
AP0 - AP8
MP0, MP1
FP
BUS
PWR
*1 Either line/trunk circuit cards or application circuit cards can be mounted in these slots.
*2 Either line/trunk circuit card, PN-CP01 or an application circuit card is to be mounted in this slot
according to the system configuration.
*3 PN-BS00-A/PN-BS00-B, PN-BS01-A/PN-BS01-B or an application circuit card is to be mounted in
this slot according to the system configuration.
Figure 3-1 Circuit Card Mounting Slots (Continued)
CHAPTER 3
Page 10
Revision 2.2
ND-45504 (E)
Addendum-002
OCTOBER, 1998
2. INSTALLATION CONDITIONS FOR CONTROL CIRCUIT CARDS
2.1 PN-CP00/PN-CP00-B/PN-CP00-C (MP)
Mount the PN-CP00/PN-CP00-B/PN-CP00-C in the MP slot of PIM0.
2.2 PN-CP01 (FP)
1. The PN-CP01 is required only if any of the following is true.
•
•
•
•
More than one PIM is used.
A PN-2DLCC is used.
A PN-AP01 is used.
OAI, ACD, No. 7 CCIS or ISDN is used.
2. When the system is equipped with two PIMs, mount one PN-CP01 in the FP slot of PIM0. When the sys-
tem is equipped with more than two PIMs--depending on the number of additional PIMs used--mount one
PN-CP01 in the FP slot of PIM0 and one PN-CP01 in the MP/FP slot of PIM2, PIM4 and PIM6.
PIM3
PIM2
PIM1
PIM0
PIM7
PIM6
PIM5
PIM4
F
P
F
P
F
P
M
P
F
P
Figure 3-2 MP/FP Card Mounting Slots
ND-45504 (E)
Addendum-002
OCTOBER, 1998
CHAPTER 3
Page 11
Revision 2.2
2.3 PN-CP02/PN-CP02-C (MP)
Mount the PN-CP02/PN-CP02-C in the MP0 and MP1 slot of PIM(H)0.
This card is used only for Back up MP system.
PIM3
PIM7
PIM6
PIM5
PIM4
F
P
F
P
PIM2
PIM1
F
P
M
M
F
P
PIM(H)0
P
P
1
0
Figure 3-3 MP/FP Card Mounting Slots for Back up MP System
CHAPTER 3
Page 12
Revision 2.2
ND-45504 (E)
Addendum-002
OCTOBER, 1998
2.4 PN-BS00-A/PN-BS00-B (BS00), PN-BS01-A/PN-BS01-B (BS01)
1. In a one-PIM system, neither the PN-BS00-A/PN-BS00-B nor the PN-BS01-A/PN-BS01-B is needed.
2. When the system is equipped with more than one PIM, mount a PN-BS00-A/PN-BS00-B in the BUS slot
of PIM0 or PIM(H)0.
3. When the system is equipped with more than one PIM, mount one PN-BS01-A/PN-BS01-B in the BUS
slot of PIM1 through PIM7, as required.
B
S
0
1
B
S
0
1
PIM3
PIM2
PIM1
PIM7
PIM6
PIM5
PIM4
B
S
0
1
B
S
0
1
B
S
0
1
B
S
0
1
B
S
0
0
B
S
0
1
PIM0
or
PIM(H)0
Figure 3-4 BS00/BS01 Card Mounting Slots
2.5 PN-PW00 (EXTPWR)
Mount the PW00 card into the LT01-AP8 slot. A maximum of three PW00 cards can be mounted in one frame
(4PIMs).
Note: The PW00 card occupies the adjoining left side (smaller number) slot because of its two-stories structure.
2.6 PZ-PW86 (PWR)
Mount one PZ-PW86 in the PWR slot of PIM0/PIM(H)0 through PIM7, as required.
ND-45504 (E)
CHAPTER 3
Page 13
Revision 2.0
3. INSTALLATION CONDITIONS FOR APPLICATION CIRCUIT CARDS
1. When the system is equipped with only one PIM:
•
•
An application circuit card can be mounted in the AP0 through AP6, and AP8 slots.
An application circuit card can not be mounted in the AP6 slot if any of the following is true.
–
A PN-2DLCC is used.
–
–
–
A PN-AP01 is used.
OAI, ACD, No. 7 CCIS or ISDN is used.
The PN-CP02s are used.
2. When the system is equipped with more than one PIM:
•
•
•
•
An application circuit card can be mounted in the AP0 through AP5 slots of PIM0/PIM(D)0.
An application circuit card can be mounted in the AP0 through AP6 slots of PIM2, 4 and 6.
An application circuit card can be mounted in the AP0 through AP7 slots of PIM1, 3, 5 and 7.
If the system is equipped with CP02s, the AP5 and AP6 slot of PIM(H)0 cannot be used for an appli-
cation circuit card.
Note 1: The application circuit card (PN-24DTA/PN-24DTA-A/PN-30DTC/PN-30DTC-A) cannot be mounted
in either the AP7 or the AP8 slot since neither of these slots have a connection to the MDF through the
Back Wiring Board.
Note 2: The application circuit card (PN-24DTA/PN-24DTA-A/PN-30DTC/PN-30DTC-A [DT10, DT11] which
receives a clock signal must be mounted in the AP0 through AP5 slots of PIM0/PIM(H)0.
Note 3: The application circuit card (PN-CK00) must be mounted in the AP0 through AP6 slots of PIM0/
PIM(H)0.
Note 4: The application circuit card (PN-CC00/PN-CC01) can be mounted in any one of the LT slots or the AP
slots.
PN-CC00 card needs two LT/AP slots per one card.
Note 5: The application circuit card (PN-CC00/PN-CC01) should be mounted in a LT/AP slot that adjoins an
AP slot for the PN-AP01 card because the cable (48-TW0.3 CONN CA) is connected between the PN-
CC00/PN-CC01 card and the PN-AP01 card.
CHAPTER 3
Page 14
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
LT SLOTS (00-09)
PIM0-7
PWR
*
BUILT-IN BATTERY
•
Line/trunk circuit cards can also be mounted in AP0 - AP5 slots.
LT SLOTS (00-09)
PIMH (0)
PWR
*
BUILT-IN BATTERY
•
Line/trunk circuit cards can also be mounted in AP0 - AP5 slots.
Figure 3-5 Application Circuit Card Mounting Slots
ND-45504 (E)
CHAPTER 3
Page 15
Revision 2.0
4. INSTALLATION CONDITIONS FOR LINE/TRUNK CIRCUIT CARDS
Mount the line/trunk circuit cards in the LT00 through LT15 slots of PIM0/PIM(H)0 through PIM7.
PIM0-7
PWR
*
BUILT-IN BATTERY
•
Application circuit cards can also be mounted in the LT10 through LT15 slots.
PIM(H)0
PWR
*
BUILT-IN BATTERY
•
Application circuit cards can also be mounted in the LT10 through LT15 slots.
Figure 3-6 Line/Trunk Circuit Card Mounting Slots
CHAPTER 3
Page 16
ND-45504 (E)
Revision 2.0
CHAPTER 4
LAMP INDICATIONS AND SWITCH SETTINGS
This chapter explains various circuit cards used in the PBX with respect to the following items. Explanations
are given in the alphabetical order of the circuit card names within each circuit card category (Control, Appli-
cation, and Line/Trunk).
1. Locations of Lamps, Switches, and Connectors
The locations of lamps, switches, and connectors of each circuit card are shown by a face layout.
2. Lamp Indications
The name, color, and functions of each indicator lamp equipped on each circuit card are shown and de-
scribed in a table.
3. Switch Settings
The name, settings, and functions of each switch equipped on each circuit card are shown and described in
a table.
Each switch setting table has a “CHECK” column. Make necessary entries in the CHECK column during and/
or after system installation and maintenance, and use each table as a reference for subsequent system mainte-
nance and operations.
ND-45504 (E)
CHAPTER 4
Page 17
Revision 2.0
1. PRECAUTION IN HANDLING
When handling a circuit card, the installer must wear a grounded wrist strap to protect the circuit card from static
electricity.
• WHEN PLUGGING/UNPLUGGING A CIRCUIT CARD
PBX
FRAME GROUND SCREW
CONNECT THE GROUND WIRE TO THE
FRAME EARTH OF THE EQUIPMENT.
WRIST STRAP
NEVER TOUCH THE COMPONENTS OR
• WHEN HOLDING A CIRCUIT CARD
SOLDERED SURFACE WITH BARE HANDS.
CARD FRONT
Figure 4-1 Static Electricity Precautions (1 of 2)
CHAPTER 4
Page 18
ND-45504 (E)
Revision 2.0
• WHEN SETTING SWITCHES ON A CIRCUIT CARD
CIRCUIT
CARD
WEAR A WRIST STRAP AND PERFORM
THE WORK STANDING ON A GROUNDED
CONDUCTIVE WORK SURFACE.
• WHEN CARRYING A CIRCUIT CARD
CIRCUIT
CARD
CONDUCTIVE
POLYETHYLENE
BAG
WHEN CARRYING A CIRCUIT
CARD AROUND, KEEP THE
CARD IN THE CONDUCTIVE
POLYETHYLENE BAG.
Figure 4-1 Static Electricity Precautions (2 of 2)
ND-45504 (E)
CHAPTER 4
Page 19
Revision 2.0
CAUTION
The installer must hold the edge of circuit card, when plugging or unplugging the circuit card. If you touch
another area, you may be exposed to hazardous voltages.
PBX
NEVER TOUCH THE COMPONENTS
OR SOLDERED SURFACE WITH
BASE HANDS.
CARD FRONT
Figure 4-2 Circuit Card Handling Precautions
CHAPTER 4
Page 20
ND-45504 (E)
Revision 2.0
2. LAMP INDICATIONS AND SWITCH SETTINGS OF CONTROL CIRCUIT CARDS
Table 4-1 below shows the control circuit cards to be explained in this section.
Table 4-1 Table of Control Circuit Cards
EXTRACTION/INSERTION
EXISTENCE OF
LAMPS
X: PROVIDED
EXISTENCE OF
SWITCHES
X: PROVIDED
NAME
(FUNCTIONAL
NAME)
WITH POWER ON
X: ALLOWED
∆: ALLOWED AFTER MB*
—: NOT ALLOWED
REFERENCE
PAGE
—: NOT PROVIDED —: NOT PROVIDED
PN-BS00-A/
PN-BS00-B (BS00)
—
X
∆
22
PN-BS01-A (BS01)
PN-BS01-B (BS01)
PN-CP00 (MP)
—
—
X
X
X
X
∆
∆
24
26
28
—
PN-CP00-B
/PN-CP00-C (MP)
X
X
—
31
PN-CP03
/PN-CP03-C (MP)
X
X
X
X
X
X
—
∆
∆
34
37
39
PN-CP01 (FP)
PN-CP02
/PN-CP02-C (MP)
PN-PW00
(EXTPWR)
X
X
∆
42
PZ-PW86 (PWR)
X
X
X
X
X
X
—
—
—
44
46
48
PZ-PW86-A (PWR)
PZ-PW86(C) (PWR)
PZ-PW86(D)
(PWR)
X
X
—
50
* MB = Make Busy
ND-45504 (E)
Addendum-002
OCTOBER, 1998
CHAPTER 4
Page 21
Revision 2.2
PN-BS00-A/PN-BS00-B (BS00)
PN-BS00-A/PN-BS00-B (BS00)
1. Locations of Lamps, Switches, and Connectors
MB
CN2
CN1
PN-BS00-A/PN-BS00-B (BS00) Card
2. Lamp Indications
This card has no indicator lamps.
CHAPTER 4
ND-45504 (E)
Page 22
Revision 2.0
PN-BS00-A/PN-BS00-B (BS00)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
For make-busy
CHECK
MB (Toggle SW)
UP
ON
For normal operation
DOWN
Note
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.
ND-45504 (E)
CHAPTER 4
Page 23
Revision 2.0
PN-BS01-A (BS01)
PN-BS01-A (BS01)
1. Locations of Lamps, Switches, and Connectors
MB
CN2
SW13
CN1
PN-BS01-A (BS01) Card
2. Lamp Indications
This card has no indicator lamps.
CHAPTER 4
ND-45504 (E)
Page 24
Revision 2.0
PN-BS01-A (BS01)
CHECK
(3) Switch Settings
Switch Settings
SWITCH
SETTING
NUMBER POSITION
SWITCH NAME
FUNCTION
MB (Toggle SW)
UP
For make-busy
ON
For normal operation
DOWN
Note
SW13 (Dip SW)
ON
Set SW13 according to the mounting location of this
card.
1, 5
OFF
ON
1 2 3 4 5 6 7 8
ON
2, 6
SWITCH
OFF
SW13 SW13 SW13 SW13
No.
MOUNTING
LOCATION
-1, 5
-2, 6
-3,7
-4, 8
ON
3, 7
PIM1
ON
OFF
OFF
OFF
OFF OFF
OFF
OFF
OFF
ON
OFF
PIM2, PIM3
PIM4, PIM5
PIM6, PIM7
ON
OFF
OFF
ON
ON
4, 8
OFF OFF
OFF
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.
ND-45504 (E)
CHAPTER 4
Page 25
Revision 2.0
PN-BS01-B (BS01)
PN-BS01-B (BS01)
1. Locations of Lamps, Switches, and Connectors
SW0
MB
CN2
CN1
PN-BS01-B (BS01) Card
2. Lamp Indications
This card has no indicator lamps.
CHAPTER 4
ND-45504 (E)
Page 26
Revision 2.0
PN-BS01-B (BS01)
CHECK
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
SW0 (Rotary SW)
Set this rotary switch to match the location in which this circuit
card is to be mounted.
For mounting this card in PIM1
For mounting this card in PIM2, 3
For mounting this card in PIM4, 5
For mounting this card in PIM6, 7
Not used
0
1
2
3
0 - 3
4 - F
Note 1
MB (Toggle SW)
For make-busy
UP
ON
For normal operation
DOWN
Note 2
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the desired switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
CHAPTER 4
Page 27
Revision 2.0
PN-CP00 (MP)
PN-CP00 (MP)
1. Locations of Lamps, Switches, and Connectors
SW3
RUN
SW1
SW2
CLKIN
JP0
RS
PN-CP00 (MP) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
Green
Green
Flashes at 120 IPM while the circuit card is operating normally.
Lights while receiving clock signals to the PLO oscillator.
CLKIN
CHAPTER 4
ND-45504 (E)
Page 28
Revision 2.0
PN-CP00 (MP)
CHECK
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
SW3 (Rotary SW)
On Line (Call processing is in progress)
0
2
Off Line (Call processing is stopped)
• I/O port: Depending on
CM40 YY=08
0
Off Line (Call processing is stopped)
• I/O port: 1200 bps (Fixed)
3
0 ~ F
B
C
For clearing the office data
For setting the resident system program
Note
1, 4 ~ 9
A, D ~ F
Not used
SW1 (Push SW)
For initializing the CPU
KF Mode
SW2 (Piano Key SW)
ON
1
OFF
MF/PF Mode.
OFF
Selection of PLO (Phase Locked Oscillator)
• When using the internal PLO of MP card:
4
3
2
1
SWITCH NUMBER
FUNCTION
1.5 MHz clock
2
3
ON
OFF
OFF
[For PN-24DTA/PN-24DTA-A]
2, 3
192 kHz clock
[For PN-BRTA]
ON
OFF
2 MHz clock
OFF
ON
ON
ON
[For PN-30DTC/PN-30DTC-A/
PN-2BRTC]
Not used
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 29
Revision 2.1
PN-CP00 (MP)
Switch Settings (Continued)
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SW2 (Piano Key SW)
• When using the PLO card (PN-CK00):
SW2-2
OFF
SW2-3
ON
OFF
2, 3
4
3
2
1
• When not using the internal PLO and the PLO card:
SW2-2
OFF
SW2-3
OFF
ON
4
Not used
OFF
JP0 (Jumper pin)
LEFT
RIGHT
UP
For factory testing
Front
For normal operation
JP2 (Jumper pin)
For normal operation
Memory backup connected
For factory test only
Disconnect battery
DOWN
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note: Set the groove on the switch knob to the desired switch position.
CAUTION
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its
mounting slot.
CHAPTER 4
Page 30
ND-45504 (E)
Revision 2.0
PN-CP00-B/PN-CP00-C (MP)
PN-CP00-B/PN-CP00-C (MP)
1. Locations of Lamps, Switches, and Connectors
SW3
RUN
SW1
SW2
CLKIN
RS
[CP00-B] Note JP0
[CP00-C] Note
JP0
Note: Location of JP0 is different between CP00-B and CP00-C.
PN-CP00-B/PN-CP00-C (MP) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
Green
Green
Flashes at 120 IPM while the circuit card is operating normally.
Lights while receiving clock signals to the PLO oscillator.
CLKIN
ND-45504 (E)
Addendum-002
OCTOBER, 1998
CHAPTER 4
Page 31
Revision 2.2
PN-CP00-B/PN-CP00-C (MP)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SW3 (Rotary SW)
0
2
On Line (Call processing is in progress)
Off Line (Call processing is stopped)
• I/O port: Depending on CM40 YY=08
0
Off Line (Call processing is stopped)
• I/O port: 1200 bps (Fixed)
3
0 ~ F
B
C
For clearing the office data
Note
For setting the resident system program
1, 4 ~ 9
A, D ~ F
Not used
SW1 (Push SW)
For initializing the CPU
KF Mode
SW2 (Piano Key SW)
ON
1
OFF
MF/PF Mode
OFF
Selection of PLO (Phase Locked Oscillator)
• When using the internal PLO of MP card:
8
7
6
5
4
3
2
1
SWITCH NUMBER
FUNCTION
1.5 MHz clock
2
3
OFF
OFF
[For PN-24DTA/PN-24DTA-A]
2, 3
192 kHz clock
[For PN-BRTA]
ON
OFF
2 MHz clock
ON
OFF
ON
ON
ON
[For PN-30DTC/PN-30DTC-A
/PN-2BRTC]
Not used
CHAPTER 4
Page 32
Revision 2.2
ND-45504 (E)
Addendum-002
OCTOBER, 1998
PN-CP00-B/PN-CP00-C (MP)
Switch Settings (Continued)
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SW2 (Piano Key SW)
• When using the PLO card (PN-CK00):
SW2-2
OFF
SW2-3
ON
OFF
2, 3
8
7
6
5
4
3
2
1
• When not using the internal PLO and the PLO card:
SW2-2
OFF
SW2-3
OFF
4 ~ 8
Not used
OFF
ON
JP0 (Jumper pin)
For normal operation
Memory backup connected
UP
For factory testing
(Disconnect battery for memory backup.)
DOWN
Front
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION column
indicate the standard setting of the switch. When the switch is not set as shown by the figure and
setting of the switch varies with the system concerned.
, the
Note: Set the groove on the switch to the desired switch position.
CAUTION
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its
mounting slot.
ND-45504 (E)
Addendum-002
OCTOBER, 1998
CHAPTER 4
Page 33
Revision 2.2
PN-CP03/PN-CP03-C (MP)
PN-CP03/PN-CP03-C (MP)
1. Locations of Lamps, Switches, and Connectors
SW3
RUN
SW1
SW2
JACK
CLK
JP0
JP1
VR
RS1
RS0
PN-CP03/PN-CP03-C (MP) Card
Lamp Indications
2. Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
Green
Green
Flashes at 120 IPM while the circuit card is operating normally.
Lights while receiving clock signals to the PLO oscillator.
CLKIN
CHAPTER 4
Page 34
Revision 2.2
ND-45504 (E)
Addendum-002
OCTOBER, 1998
PN-CP03/PN-CP03-C (MP)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
On Line (Call processing is in progress)
CHECK
SW3 (Rotary SW)
0
2
Off Line (Call processing is stopped)
• I/O port: Depending on CM40 YY=08
Off Line (Call processing is stopped)
• I/O port: 1200 bps (Fixed)
3
0 ~ F
Note
B
C
For clearing the office data
For setting the resident system program
1, 4 ~ 9
A, D ~ F
Not used
SW1 (Push SW)
For initializing the CPU
KF Mode
SW2 (Piano Key SW)
ON
1
OFF
MF/PF Mode
OFF
Selection of PLO (Phase Locked Oscillator)
When using the internal PLO of MP card:
4
3
2
1
SWITCH NUMBER
FUNCTION
1.5 MHz clock
[For PN-24DTA/PN-24DTA-A]
192 kHz clock
2
3
OFF
OFF
ON
2, 3
ON
OFF
[For PN-BRTA]
2 MHz clock
OFF
ON
ON
ON
[For PN-30DTC/PN-30DTC-A
/PN-2BRTC]
Not used
ND-45504 (E)
Addendum-002
OCTOBER, 1998
CHAPTER 4
Page 35
Revision 2.2
PN-CP03/PN-CP03-C (MP)
Switch Settings (Continued)
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SW2 (Piano Key SW)
• When using the PLO card (PN-CK00):
SW2-2
OFF
SW2-3
ON
OFF
2, 3
• When not using the internal PLO and the PLO card:
SW2-2
OFF
SW2-3
OFF
4
3
2
1
ON
When using RS1 port for built-in MODEM
When using RS1 port for RS-232C.
4
ON
OFF
VR (Rotary SW)
Variable Resister for External Hold Tone
Source
(0 - 20 KΩ: Clockwise)
20
0
JP0 (Jumper pin)
For normal operation
UP
DOWN
UP
Memory backup connected
For factory testing
(Disconnect battery for memory backup.)
Front
JP1 (Jumper pin)
For normal operation
DOWN
For using External Tone Source
Front
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note: Set the groove on the switch knob to the desired switch position.
CAUTION
When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from its
mounting slot. When the CP03/CP03-C is plugged in and power is on, do not move Jumper JP1.
CHAPTER 4
Page 36
Revision 2.2
ND-45504 (E)
Addendum-002
OCTOBER, 1998
PN-CP01 (FP)
PN-CP01 (FP)
1. Locations of Lamps, Switches, and Connectors
SW1
RUN
MB
PN-CP01 (FP) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
Green
FUNCTION
RUN
Flashes at 120 IPM while the circuit card is operating normally.
ND-45504 (E)
CHAPTER 4
Page 37
Revision 2.0
PN-CP01 (FP)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SW1 (Rotary SW)
Set this rotary switch to match the location in which this cir-
cuit card is to be mounted.
0
1
2
3
For mounting this card in PIM0
For mounting this card in PIM2
For mounting this card in PIM4
For mounting this card in PIM6
Not used
0 – 3
4 – F
Note 1
MB (Toggle SW)
UP
For make-busy
ON
For normal operation
DOWN
Note 2
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the desired switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Note 3:
The PN-CP01 is required only if any of the following is true:
•
•
•
•
More than one PIM is used.
A PN-2DLCC is used.
A PN-AP01 is used.
OAI, ACD, No. 7 CCIS, or ISDN is used.
CHAPTER 4
Page 38
ND-45504 (E)
Revision 2.0
PN-CP02/PN-CP02-C (MP)
PN-CP02/PN-CP02-C (MP)
1. Locations of Lamps, Switches, and Connectors
SW3
RUN
SW1
SW2
CLKIN
STBY
[CP02] Note
JP0
SW4
MT
RS
[CP02-C] Note JP0
Note: Location of JP0 is different between CP02 and CP02-C.
PN-CP02/PN-CP02-C (MP) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Flashes at 120 IPM while the circuit card is active status and operating normally.
• Flashes at 30 IPM or 15 IPM while the circuit card is stand by status.
Normally operating: 30 IPM (1 sec - ON, 1 sec - OFF)
RUN
Green
Copying office data: 15 IPM (3 sec - ON, 1 sec - OFF)
CLKIN
STBY
Green
Red
Lights while receiving clock signals to the PLO oscillator.
Lights when the circuit card is in the standby mode.
ND-45504 (E)
Addendum-002
OCTOBER, 1998
CHAPTER 4
Page 39
Revision 2.2
PN-CP02/PN-CP02-C (MP)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SW3 (Rotary SW)
On Line (Call processing is in progress)
0
2
Off Line (Call processing is stopped)
• I/O port: Depending on CM40 YY=08
0
Off Line (Call processing is stopped)
• I/O port: 1200 bps (Fixed)
3
0 ~ F
Note 2
Note 1
B
C
For clearing the office data
For setting the resident system program
1, 4 ~ 9
A, D ~ F
Not used
SW1 (Push SW)
For initializing the CPU
KF Mode
SW2 (Piano Key SW)
ON
1
OFF
MF/PF Mode
OFF
Selection of PLO (Phase Locked Oscillator)
• When using the internal PLO of MP card:
8
7
6
5
4
3
2
1
SWITCH
NUMBER
FUNCTION
2
3
1.5 MHz clock
[For PN-24DTA/PN-24DTA-A]
OFF
OFF
2, 3
192 kHz clock
[For PN-BRTA]
ON
OFF
ON
2 MHz clock
OFF
ON
ON
ON
[For PN-30DTC/PN-30DTC-A/PN-
2BRTC]
Not used
CHAPTER 4
Page 40
Revision 2.2
ND-45504 (E)
Addendum-002
OCTOBER, 1998
PN-CP02/PN-CP02-C (MP)
Switch Settings (Continued)
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SW2 (Piano Key SW)
• When using the PLO card (PN-CK00):
SW2-2
OFF
SW2-3
ON
OFF
2, 3
8
7
6
5
4
3
2
1
• When not using the internal PLO and the PLO card:
SW2-2
OFF
SW2-3
OFF
4 ~ 7
Not used
OFF
ON
ON
Allowed to use MAT
8
Note 3
For normal operation
(Not allowed to use MAT)
OFF
JP0 (Jumper pin)
For normal operation
Memory backup connected
UP
Front
For factory test only
(Disconnect battery for memory backup.)
DOWN
UP
SW4 (Toggle SW)
For make-busy
ON
For normal operation
DOWN
Note 4
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch to the desired switch position.
On the stand by status circuit card, the SW3 can be set to only “0” or “B”. Do not set to the other
position (1-9, A, C-F).
Note 3:
Note 4:
MP0 and MP1 must not set to “ON” at the same time.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
Addendum-002
OCTOBER, 1998
CHAPTER 4
Page 41
Revision 2.2
PN-PW00 (EXTPWR)
PN-PW00 (EXTPWR)
1. Locations of Lamps, Switches and Connectors
RUN
MB
CONN
PN-PW00 (EXTPWR) Card
Lamp Indications
2. Lamp Indications
LAMP NAME
COLOR
Green
FUNCTION
RUN
Remains lit while –48 V power is being supplied
CHAPTER 4
Page 42
ND-45504 (E)
Revision 2.0
PN-PW00 (EXTPWR)
CHECK
(3) Switch Setting
Switch Settings
SWITCH
NAME
SWITCH
SETTING
FUNCTION
NUMBER
POSITION
MB (Toggle SW)
For make-busy (–48 V power off)
UP
ON
For normal operation (–48 V power on)
Note
DOWN
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note: When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.
ND-45504 (E)
CHAPTER 4
Page 43
Revision 2.0
PZ-PW86 (PWR)
PZ-PW86 (PWR)
1. Locations of Lamps, Switches, and Connectors
SW102
MJ
MJ
MN
ON
MN
ON
ON
1
2
GND
FG
GND
–27V
FG
–27V
ON
–
OFF
100/120
240
SIDE VIEW
FRONT VIEW
PZ-PW86 (PWR) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
MJ
MN
ON
Red
Lights upon occurrence of a major trouble
Lights upon occurrence of a minor trouble
Yellow
Green
Remains lit while the operating power is being supplied
CHAPTER 4
ND-45504 (E)
Page 44
Revision 2.0
PZ-PW86 (PWR)
CHECK
(3) Switch Settings
Switch Settings
SETTING
SWITCH
SWITCH NAME
FUNCTION
NUMBER
POSITION
Set to ON.
1
ON
ON
Standard setting (for equalize charging)
Not used
1
2
ON
OFF
ON
2
SW
For turning AC source power on
For turning AC source power off
AC INPUT: 90 V - 138 V
AC INPUT: 180 V - 276 V
I (ON)
O (OFF)
OFF
100/120
240
UP
DOWN
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
CAUTION
• When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from
its mounting slot.
• Set the appropriate voltage by using the AC voltage select switch (slide switch) before powering on.
ND-45504 (E)
CHAPTER 4
Page 45
Revision 2.0
PZ-PW86-A (PWR)
PZ-PW86-A (PWR)
1. Locations of Lamps, Switches, and Connectors
SW102
MJ
SW102
MJ
MN
ON
MN
ON
ON
1
2
GND
FG
GND
–27V
FG
–27V
ON
–
OFF
100/120
240
SIDE VIEW
FRONT VIEW
PZ-PW86-A (PWR) Card
Lamp Indications
2. Lamp Indications
LAMP NAME
COLOR
FUNCTION
MJ
MN
ON
Red
Lights upon occurrence of a major trouble
Lights upon occurrence of a minor trouble
Yellow
Green
Remains lit while the operating power is being supplied
CHAPTER 4
ND-45504 (E)
Page 46
Revision 2.0
PZ-PW86-A (PWR)
CHECK
(3) Switch Settings
Switch Settings
SETTING
SWITCH
SWITCH NAME
FUNCTION
NUMBER
POSITION
SW102
To start each PIM on battery power, when AC
power is not provided (Switch “SW” must be
ON).
PRESS
MOMENTARILY
1
2
Set to ON.
ON
ON
ON
1
2
For float charging
Standard setting for equalize charging (Set to
equalize for Gel cell or no battery.)
OFF
ON
SW
For turning AC source power on
For turning AC source power off
AC INPUT: 90 V - 138 V
I (ON)
O (OFF)
OFF
100/120
UP
DOWN
AC INPUT: 180 V - 276 V
240
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
CAUTION
• When the operating power is being supplied to this circuit card, do not plug/unplug this circuit card into/from
its mounting slot.
• Set the appropriate voltage by using the AC voltage select switch (slide switch) before powering on.
ND-45504 (E)
CHAPTER 4
Page 47
Revision 2.0
PZ-PW86 (C) (PWR)
PZ-PW86 (C) (PWR)
1. Locations of Lamps, Switches, and Connectors
BATTERY
START
SW102
MJ
MN
ON
ON
1
2
MODE
ON
GND
FG
2
1
–27V
SW301
SIG
SW1
BATT2
ON
OFF
BATT1
100/120VAC
240VAC
AC INPUT
SIDE VIEW
FRONT VIEW
PZ-PW86(C) (PWR) Card
Lamp Indications
2. Lamp Indications
LAMP NAME
COLOR
FUNCTION
MJ
MN
ON
Red
Lights upon occurrence of a major trouble
Lights upon occurrence of a minor trouble
Orange
Green
Remains lit while the operating power is being supplied
CHAPTER 4
ND-45504 (E)
Page 48
Revision 2.0
PZ-PW86 (C) (PWR)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
Always set to OFF
CHECK
MODE
1
OFF
ON
Float charging, for sealed batteries (Normal
Setting).
OPTION: Periodic Equalize charging of
external vented batteries.
ON
1
2
2
Flaot charging, for vented batteries only.
OFF
ON
SW1
For turning AC power and the battery on
For turning AC power and the battery off
ON (I)
OFF
OFF (O)
AC INPUT: 90 V - 138 V
AC INPUT: 180 V - 264 V
100/120 VAC
UP
DOWN
240 VAC
SW102
To start each PIM on battery power, when
AC power is not provided (switch “SW”
must be ON)
PRESS
MOMENTARILY
SW301
ON
OFF
ON
CR Voltage: 75 Vrms
CR Voltage: 90 Vrms
Frequency: 20 Hz
1
2
20Hz
25Hz
2
1
ON
OFF
90V
Frequency: 25 Hz
75V
OFF
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
ND-45504 (E)
CHAPTER 4
Page 49
Revision 2.0
PZ-PW86 (D) (PWR)
PZ-PW86 (D) (PWR)
1. Locations of Lamps, Switches, and Connectors
MJ
MN
ON
ON
1
2
MODE
BATTERY
START
SW102
ON
2
1
GND
FG
–27V
SW301
SIG
(CN103)
SIG
(CN103)
BATT2
BATT1
100/120VAC
240VAC
SW1
ON
OFF
AC INPUT
SIDE VIEW
FRONT VIEW
PZ-PW86(D) (PWR) Card
Lamp Indications
2. Lamp Indications
LAMP NAME
COLOR
FUNCTION
MJ
MN
ON
Red
Lights upon occurrence of a major trouble
Lights upon occurrence of a minor trouble
Orange
Green
Remains lit while the operating power is being supplied
CHAPTER 4
ND-45504 (E)
Page 50
Revision 2.0
PZ-PW86 (D) (PWR)
(3) Switch Settings
Switch Settings
SETTING
SWITCH
NUMBER
SWITCH NAME
FUNCTION
CHECK
POSITION
MODE
1
Always set to OFF
OFF
Float charging, for sealed batteries (Normal
Setting).
OPTION: Periodic Equalize charging of
external vented batteries.
ON
ON
1
2
2
Flaot charging, for vented batteries only.
OFF
ON
SW1
For turning AC power and the battery on
For turning AC power and the battery off
ON (I)
OFF
OFF (O)
AC INPUT: 90 V - 138 V
AC INPUT: 180 V - 264 V
100/120 VAC
UP
DOWN
240 VAC
SW102
To start each PIM on battery power, when
AC power is not provided (switch “SW”
must be ON)
PRESS
MOMENTARILY
SW301
ON
OFF
ON
CR Voltage: 75 Vrms
CR Voltage: 90 Vrms
Frequency: 20 Hz
1
2
20Hz
25Hz
2
1
ON
OFF
90V
Frequency: 25 Hz
75V
OFF
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
ND-45504 (E)
CHAPTER 4
Page 51
Revision 2.0
3. LAMP INDICATIONS AND SWITCH SETTINGS OF APPLICATION CIRCUIT CARDS
Table 4-2 below shows the application circuit cards to be explained in this section.
Table 4-2 Table of Application Circuit Cards
EXTRACTION/INSER-
EXISTENCE OF
LAMPS
X: PROVIDED
EXISTENCE OF
SWITCHES
X: PROVIDED
NAME
(FUNCTIONAL
NAME)
TION WITH POWER ON
X: ALLOWED
REFERENCE
PAGE
∆: ALLOWED AFTER MB*
—: NOT PROVIDED —: NOT PROVIDED
—: NOT ALLOWED
PN-AP00-A (AP00)
PN-AP01 (AP01)
PN-BRTA (BRI)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
∆
∆
∆
∆
X
53
59
62
PN-2BRTC (BRI)
PN-CC00 (ETHER)
PN-CC01 (ETHER)
PN-CK00 (PLO)
65-1
66
∆
∆
∆
∆
68-1
69
PN-24DTA (DTI)
PN-24DTA-A (DTI)
72
75
PN-30DTC/30DTC-A
(DTI)
X
X
∆
78-1
PN-ME00 (EXTMEM)
PN-4RSTB (MFR)
PN-4RSTC (CIR)
PN-SC00 (CCH)
PN-SC01 (DCH)
PN-SC02 (ICH)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
∆
∆
∆
∆
∆
∆
∆
∆
79
84
86
88
91
94
96
98
PN-SC03 (ICH)
PN-SC03 (CSH)
* MB=Make Busy
CHAPTER 4
Page 52
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
PN-AP00-A (AP00)
PN-AP00-A (AP00)
1. Locations of Lamp, Switches, and Connectors
SENSE
RUN
MB
J16
SW1
WE
L3
L2
L1
L0
RS3
RS2
RS1
RS0
SW0
PN-AP00-A (AP00) Card
ND-45504 (E)
CHAPTER 4
Page 53
Revision 2.0
PN-AP00-A (AP00)
(2) Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
WE
Green
Red
Flashes at 120 IPM while this card is operating normally.
Not used.
Second data setting value for the first data 250 of CM D001
L0 - L3
0
1 (port 0) - 3 (port 2)
Indication of the transmitting status of Indication of the status of CTS signal on
port 0 port 0 - 2
Indication of the transmitting status of Indication of the status of DCD signal
port 1 on port 0 - 2
Indication of the transmitting status of Indication of the status of TXD signal
port 2 on port 0 - 2
Indication of the transmitting status of Indication of the status of RXD signal
port 3 on port 0 - 2
L3
L2
L1
L0
Green
CHAPTER 4
Page 54
ND-45504 (E)
Revision 2.0
PN-AP00-A (AP00)
CHECK
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
SENSE
(Rotary SW)
Set the switch to match the AP Number (04 - 15) to be set by
CM05.
4 - F
04 05 06 07 08 09 10 11 12 13 14 15
AP NO.
SW NO.
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 - 3
Not used
MB (Toggle SW)
UP
For make-busy
ON
For normal operation
DOWN
Note 2
SW1 (Piano Key SW)
For normal operation
Not used
ON
1
2
OFF
OFF
For normal operation
ON
4
3
2
1
OFF
For AP data clearing by CMD100/CMD101
For normal operation
ON
3
4
OFF
For AP data clearing by CMD100/CMD101
Always set to OFF
ON
OFF
J16 (Jumper pin)
Memory backup ON
RIGHT
Memory backup OFF
LEFT
Front
ND-45504 (E)
CHAPTER 4
Page 55
Revision 2.0
PN-AP00-A (AP00)
Switch Settings (Continued)
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SW0 (Dip SW)
Enables the receive clock from the DCE (Mo-
dem) side when the No. 0 Port is synchronous.
(Clock is received at the RXC terminal.)
ON
OFF
ON
ON
1 2 3 4 5 6 7 8
1
Note 3
• Uses the internal clock as the receive clock
when the No. 0 Port is synchronous
• When the No. 0 Port is asynchronous
Enables transmit clock from the DCE (Mo-
dem) side when the No. 0 Port is synchronous.
(Clock is received at the TXC (2) terminal.)
2
• Uses the internal clock as the send clock
when the No. 0 Port is synchronous
OFF
• When the No. 0 Port is asynchronous
For transmitting the send clock from the DTE
(this card) when the No. 0 Port is synchro-
nous. (Clock is transmitted from the TXC (1)
terminal.)
ON
3
4
• For not transmitting the send clock from the
DTE (this card) side when the No. 0 Port is
synchronous
OFF
• When the No. 0 Port is asynchronous
ON
When the No. 0 Port is asynchronous
When the No. 0 Port is synchronous
OFF
CHAPTER 4
Page 56
ND-45504 (E)
Revision 2.0
PN-AP00-A (AP00)
CHECK
Switch Settings (Continued)
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
SW0
FUNCTION
• Uses the internal clock as the receive
clock when the No. 0 Port is synchro-
nous.
ON
• When the No. 0 Port is asynchronous.
5
Note 4
Enables receive clock from the DCE (Mo-
dem) side when the No. 0 Port is synchro-
nous. (Clock is received at the RXC
terminal)
OFF
Set No. 0 port forcibly in a state which DSR
signal is always provided. Force DSR sig-
nal high for port 0. No SMDR buffering.
ON
OFF
ON
6
Note 5
Receive DSR signal from the DCE on No.
0 port. Detect DSR signal from DCE for
port 0. Allows SMDR records to buffer.
Set No. 1 port forcibly in a state which DSR
signal is always provided. Force DSR sig-
nal high for port 1. No SMDR buffering.
7
Note 5
Receive DSR signal from the DCE on No.
1 port. Detect DSR signal from DCE for
port 1. Allows SMDR records to buffer.
OFF
ON
Set No. 2 port forcibly in a state which
DSR signal is always provided. Force DSR
signal high for port 2. No SMDR buffering.
8
Note 5
Receive DSR signal from the DCE on No.
2 port. Detect DSR signal from DCE for
port 2. Allows SMDR records to buffer.
OFF
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
ND-45504 (E)
CHAPTER 4
Page 57
Revision 2.0
PN-AP00-A (AP00)
Note 1:
Note 2:
Set the groove on the switch knob to the desired switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Note 3:
The SW 1 is used to select the AP operating mode as shown below.
SWITCH
ON LINE
OFF LINE
SW 1-4
SW 1-3
SW 1-2
SW 1-1
OFF
ON
ON
ON
OFF
OFF
OFF
ON
On line : Normal operating mode. The AP should be always in the “On line”, other than when you delete the AP
data.
Off line : The mode for AP data clearing by the command CMD100/CMD101.
Note 4:
The use of the external clock (from the distant end) or the internal clock is determined by the following
table:
SW0
CLOCK
1
5
External
Internal
ON
OFF
OFF
ON
Note 5:
When the DCE connected to the port does not provide a function to send the DSR signals, set the switch
to ON. In this case, the AP00 card can not recognize the actual state of the DCE, so that the call records
or system messages will not be stored in the memory buffer on the AP00 card even if the cable is discon-
nected from the DCE.
When the switch is set to OFF, the call records or system messages will be stored when the cable is dis-
connected, and will be sent when the cable is re-connected.
CHAPTER 4
Page 58
ND-45504 (E)
Revision 2.0
PN-AP01 (AP01)
PN-AP01 (AP01)
1. Locations of Lamps, Switches, and Connectors
SENSE
RUN
MB
SW1
L3
L2
L1
L0
RS0
IP
SW0
PN-AP01 (AP01) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
L3
Green
Flashes at 120 IPM while this card is operating normally.
Indication of the status of CTS signal on the RS-232C port.
Indication of the status of DCD signal on the RS-232C port.
Indication of the status of TXD signal on the RS-232C port
Indication of the status of RXD signal on the RS-232C port.
L2
L0-L3
L1
Green
L0
ND-45504 (E)
CHAPTER 4
Page 59
Revision 2.0
PN-AP01 (AP01)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SENSE
(Rotary SW)
4 - F
Set the switch to match the AP Number (04 - 15) to be set by
CM05.
AP NO.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
SW NO.
Note 1
0 - 3
Not used
UP
MB(Toggle SW)
For make-busy
ON
DOWN
For normal operation
Note 2
SW1 (Piano Key
SW)
For normal operation
Not used
ON
OFF
ON
1
2
3
For normal operation
Not used
OFF
OFF
ON
4
3
2
1
For normal operation
Not used
OFF
ON
For normal operation
Not used
4
ON
OFF
CHAPTER 4
Page 60
ND-45504 (E)
Revision 2.0
PN-AP01 (AP01)
CHECK
Switch Settings (Continued)
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
SW0 (Dip SW)
1
2
3
Always set to OFF
Always set to OFF
OFF
OFF
OFF
OFF
ON
1 2 3 4
Always set to OFF
Always set to OFF
4
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the desired switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
CHAPTER 4
Page 61
Revision 2.0
PN-BRTA (BRI)
PN-BRTA (BRI)
1. Locations of Lamps, Switches, and Connectors
SENS
RUN
MB
B1
B2
D
ALM
SW0
SW1
PN-BRTA (BRI) Card
CHAPTER 4
Page 62
ND-45504 (E)
Revision 2.0
PN-BRTA (BRI)
(2) Lamp Indications
Lamp Indications on the PN-BRTA (BRI) Card
FUNCTION
LAMP NAME
COLOR
RUN
Green
Flashes at 120 IPM while this card is operating normally.
B1 channel status
ON:
OFF:
Busy
Idle
B1
B2
Green
Green
Flash (60 IPM):Make Busy
B2 channel status
ON:
OFF:
Busy
Idle
Flash (60 IPM):Make Busy
D channel status
D
Green
Red
ON:
OFF:
Busy
Idle
Transmission line fault status
ON:
ALM
Line fault
OFF:
Normal operation
ND-45504 (E)
CHAPTER 4
Page 63
Revision 2.0
PN-BRTA (BRI)
(3) Switch Settings
Switch Settings on the PN-BRTA (BRI) Card
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
SENS
4 - F
Set the switch to match the AP Number (04 - 15) as set by CM05.
(Rotary SW)
04 05 06 07 08 09 10 11 12 13 14 15
AP NO.
SW NO.
0
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 - 3
Not used
MB (Toggle SW)
For make-busy
UP
ON
For normal operation
DOWN
Note 2
SW0 (Dip SW)
For normal operation (BRI mode)
Not used
ON
1
OFF
ON
1 2 3 4
Clock signal from a master office is sent to the PLO of
MP card according to the switch setting of SW0-3.
ON
2
Note 3
Clock signal from a master office is not sent to the PLO
of MP card.
OFF
ON
Clock signal is sent to PLO 0 of MP card.
Clock signal is sent to PLO 1 of MP card.
For normal operation
3
Note 3
OFF
ON
4
1
OFF
Not used
SW1 (Dip SW)
For terminating the transmitting side of channels B1 and
B2 with 100 ohms.
ON
ON
1 2
To remove the terminating resistor on the transmitting
side of channels B1 and B2.
OFF
For terminating the receiving side of channels B1 and B2
with 100 ohms.
ON
2
To remove the terminating resistor on the receiving side
of channels B1 and B2.
OFF
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the desired switch position.
When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
CHAPTER 4
Page 64
ND-45504 (E)
Revision 2.0
PN-BRTA (BRI)
Note 3:
Set SW0-2 and SW0-3 as follows.
No. of BRI
BRI 0
BRI 1
BRI 2
....
....
BRI 11
REMARKS
SW
CONDITIONS
SW SW SW SW SW SW
0-2 0-3 0-2 0-3 0-2 0-3
SW SW
0-2 0-3
When one BRI is
provided.
The MP card will receive the clock signal
from BRI 0 at its PLO 0 input.
ON ON
When more than
one BRI is pro-
vided.
The MP card will receive the clock signal
from BRI 0 at its PLO 0 input under nor-
mal conditions.
ON ON ON OFF OFF ON
.... OFF ON Should a clock failure occur on BRI 0, the
MP card will automatically switch to the
PLO 1 input, and so derive the clock from
BRI 1.
ND-45504 (E)
CHAPTER 4
Page 65
Revision 2.0
PN-2BRTC (BRI)
PN-2BRTC (BRI)
1. Locations of Lamps, Switches, and connectors
SENS
RUN
MB
B21
B11
D1
ALM1
B20
B10
D0
ALM0
SW11
SW10
SW0
PN-2BRTC (BRI) Card
CHAPTER 4
Page 65-1
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
PN-2BRTC (BRI)
2. Lamp Indications
Lamp Indications
LAMP NAME
RUN
COLOR
Green
Red
FUNCTION
Flashes at 120 IPM while this card is operating normally.
B21
No.1 Circuit
B2 channel status
ON:
OFF:
Busy
Idle
Flash (60 IPM): Make Busy
B11
Red
B1 channel status
ON:
OFF:
Busy
Idle
Flash (60 IPM): Make Busy
D1
ALM1
B20
Green
Red
D channel status
ON: Busy
OFF: Idle
Transmission line fault status
ON: Line fault
OFF: Normal operation
Red
No.0 Circuit
B2 channel status
ON:
OFF:
Busy
Idle
Flash (60 IPM): Make Busy
B10
Red
B1 channel status
ON:
OFF:
Busy
Idle
Flash (60 IPM): Make Busy
D0
Green
Red
D channel status
ON: Busy
OFF: Idle
ALM0
Transmission line fault status
ON: Line fault
OFF: Normal operation
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 65-2
Revision 2.1
PN-2BRTC (BRI)
3. Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SENS
(Rotary SW)
4 ~ F
Set the switch to match the AP Number (04-15) as set by
CM05.
AP No.
SW No.
04 05 06 07 08 09 10 11 12 13 14 15
0
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 ~ 3
Not used
UP
MB (Toggle SW)
For make-busy
ON
For normal operation
DOWN
Note 2
SW0, SW10
(Dip SW)
For terminating the transmitting side
of channels B1 and B2 with 100 ohms.
ON
OFF
ON
1
2
1
2
ON
To remove the terminating resistor on
the transmitting side of channels B1
and B2.
For terminating the receiving side of
channels B1 and B2 with 100 ohms.
To remove the terminating resistor on
the receiving side of channels B1 and
B2.
OFF
CHAPTER 4
Page 65-3
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
PN-2BRTC (BRI)
CHECK
Switch Settings (Continued)
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
SW11 (Dip SW)
For normal operation (BRI mode)
Not used
ON
1
OFF
ON
1 2 3 4
Output clock signals according to the
switch setting of SW11-3.
ON
2
Note 3
OFF
ON
Do not output clock signals.
Output clock signals to PLO 0 of MP.
Output clock signals to PLO 1 of MP.
For normal operation
3
Note 3
OFF
ON
4
OFF
Not used
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1: Set the groove on the switch knob to the desired switch position.
Note 2: When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Note 3: The system can supply clock signals from two clock supply routes.
In normal condition, the system synchronizes to the clock signals supplied on the PLO 0 of MP card via
the Back Wiring Board, and if the clock signals are failed, the clock supply route takes over to PLO1
automatically. Set SW11-2 and SW11-3 as follows.
No. of
BRI 0
BRI 1
BRI 2
----
----
BRI 11
BRI
REMARKS
SW
SW SW SW SW SW SW
11-2 11-3 11-2 11-3 11-2 11-3
SW SW
11-2 11-3
CONDITIONS
The clock signals are supplied to the
PLO through No. 0 circuit the BRI. If
the clock supply route of No. 0 circuit
is failed, the clock supply route of No.
1 circuit takes over automatically.
When one BRI is
provided.
ON ON
The system can supply the clock
signals from BRI 0 or BRI 1. The
system is synchronized to the BRI 0
When more than
one BRI is pro-
vided.
ON ON ON OFF OFF ON ---- OFF ON clock signals normally, and if both
No. 0 circuit clock supply route and
No. 1 circuit clock supply route is
failed, the BRI 1 takes over.
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 65-4
Revision 2.1
PN-CC00 (ETHER)
PN-CC00 (ETHER)
1. Locations of Lamps, Switches, and Connectors
PN-CC00
PZ-M397
ETHER
RUN
SW
RUN
SW
ERR
S1
ERR
S1
S2
S2
S3
S3
IP
SW31
SW51
PN-CC00 (ETHER) Card
CHAPTER 4
Page 66
ND-45504 (E)
Revision 2.0
PN-CC00 (ETHER)
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
RUN
ERR
S1
Green
Red
Steadily lights while this card is operating normally.
Flashes at 120 IPM when system error occurs.
Lights when it is transmitting or receiving the data.
Lights when it can transmit or receive the data.
Lights when the power sets ON.
Green
Green
Green
S2
S3
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 67
Revision 2.1
PN-CC00 (ETHER)
(3) Switch Settings
Switch Settings
SETTING
SWITCH
NAME
SWITCH
NUMBER
FUNCTION
CHECK
POSITION
SW
(Rotary SW)
Always set to 0
Not used
0
1-F
SW51 (Dip SW)
1 (D15)
2 (D14)
3 (D13)
4 (D12)
5 (D11)
ON
ON
ON:0 OFF:1
MAC ADDRESS
SWITCH SETTING
ON
1 2 3 4 5 6 7 8
ON
00003225 1 X X X
(HEX)
OFF
ON
SW51-1 (D15) ON
SW51-2 (D14) ON
SW51-3 (D13) ON
SW51-4 (D12) OFF
Note
Fixed
OFF
ON
6 (D10)
7 (D9)
8 (D8)
1 (D7)
2 (D6)
3 (D5)
4 (D4)
5 (D3)
6 (D2)
7 (D1)
8 (D0)
OFF
ON
SW51-5 (D11) ON/OFF
SW51-6 (D10) ON/OFF
OFF
ON
SW51-7 (D9)
SW51-8 (D8)
ON/OFF
ON/OFF
OFF
ON
SW31 (Dip SW)
OFF
ON
SW31-1 (D7)
SW31-2 (D6)
SW31-3 (D5)
SW31-4 (D4)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
Note
OFF
ON
SW31-5 (D3)
SW31-6 (D2)
SW31-7 (D1)
SW31-8 (D0)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Note: Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more
than one PBX is installed in the same network, assign the lower 3 digits of the following MAC address by
SW31 and SW51 to prevent duplicate addresses.
000032251
XXX (HEX)
According to the switch setting of SW51 (D11-D8) and SW31 (D7-D0).
Fixed
CHAPTER 4
Page 68
ND-45504 (E)
Revision 2.0
PN-CC01 (ETHER)
PN-CC01 (ETHER)
1. Location of Lamps, Switches, and Connectors
SW1
SW2
RUN
MB
LINK
XMT
RCV
RVP
ERR
10 BASE-T
IP
PN-CC01 (ETHER) Card
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 68-1
Revision 2.1
PN-CC01 (ETHER)
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
RUN
COLOR
Green
Green
Green
Green
Green
Flashes at 60 IPM while this card is operating normally.
Lights when link is established.
LINK
XMT
Lights when it is transmitting the data.
Lights when it is receiving the data.
Lights only when it is receiving the data with its own IP address.
Not used
RCV
RVP
ERR
CHAPTER 4
Page 68-2
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
PN-CC01 (ETHER)
CHECK
3. Switch Settings
Switch Settings
SETTING
SWITCH
NAME
SWITCH
NUMBER
FUNCTION
POSITION
MB (Toggle SW)
UP
For make-busy
ON
For normal operation
DOWN
Note 1
SW1 (Dip SW)
1 (D15)
2 (D14)
3 (D13)
4 (D12)
5 (D11)
ON
ON
ON: 0 OFF: 1
SWITCH SETTING
MAC ADDRESS
ON
1 2 3 4 5 6 7 8
ON
00004CA4 X X X X
(HEX)
OFF
ON
SW1-1 (D15)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
Note 2
Fixed
SW1-2 (D14)
SW1-3 (D13)
SW1-4 (D12)
OFF
ON
6 (D10)
7 (D9)
8 (D8)
1 (D7)
2 (D6)
3 (D5)
4 (D4)
5 (D3)
6 (D2)
7 (D1)
8 (D0)
OFF
ON
SW1-5 (D11)
SW1-6 (D10)
SW1-7 (D9)
SW1-8 (D8)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
OFF
ON
OFF
ON
SW2 (Dip SW)
OFF
ON
SW2-1 (D7)
SW2-2 (D6)
SW2-3 (D5)
SW2-4 (D4)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON
1 2 3 4 5 6 7 8
OFF
ON
Note 2
OFF
ON
SW2-5 (D3)
SW2-6 (D2)
SW2-7 (D1)
SW2-8 (D0)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Note 1: When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the Circuit card.
Note 2: Each equipment must have a unique MAC address to distinguish between systems. Therefore, when more
than one PBX is installed in the same network, assign the lower 4 digits of the following MAC address by
SW1 and SW2 to prevent duplicate addresses.
00004CA4
XX XX (HEX)
According to the switch setting of SW2 (D7-D0)
According to the switch setting of SW1 (D15-D8)
Fixed
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 68-3
Revision 2.1
This page is for your notes.
CHAPTER 4
Page 68-4
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
PN-CK00 (PLO)
PN-CK00 (PLO)
1. Locations of Lamps, Switches, and Connectors
SYNC
PLO0
PLO1
ALM
DRFT
MB
SW0
PN-CK00 (PLO) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
SYNC
Green
Green
Lights while clock signals from this card are sent out and are not DRIFT status.
Lights while receiving clock signals from the network to the PLO0 input on this
card.
PLO0
PLO1
Lights while receiving clock signals from the network to the PLO1 input on this
card.
Green
ALM
Red
Red
Lights while clock signal from this card are not sent out.
Lights while clock signals are DRIFT status.
DRFT
DRIFT:
Means the status which the oscillation of clock signal from the PN-CK00 is not synchronized with
the network.
ND-45504 (E)
CHAPTER 4
Page 69
Revision 2.0
PN-CK00 (PLO)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
MB (Toggle SW)
UP
For make-busy
ON
For normal operation
DOWN
Note
SW0 (Piano Key SW)
Selection of PLO 0 (Phase Locked Oscillator)
SWITCH NUMBER
FUNCTION
OFF
1
2
8
7
6
5
4
3
2
1
2 MHz clock
[For PN-30DTC/PN-30DTC-A/
PN-2BRTC]
ON
ON
1, 2
1.5 MHz clock
[For PN-24DTA/PN-24DTA-A]
OFF
ON
192 kHz clock
[For PN-BRTA]
ON
OFF
OFF
OFF
Not used
ON
Selection of PLO 1 (Phase Locked Oscillator)
SWITCH NUMBER
FUNCTION
3
4
2 MHz clock
ON
ON
[For PN-30DTC/PN-30DTC-A/
PN-2BRTC]
3, 4
1.5 MHz clock
[For PN-24DTA/PN-24DTA-A]
OFF
ON
192 kHz clock
[For PN-BRTA]
ON
OFF
OFF
OFF
Not used
5 ~ 7
8
Not used
OFF
ON
PLO frequency hold circuit OFF
PLO frequency hold circuit ON
OFF
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
CHAPTER 4
Page 70
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
PN-CK00 (PLO)
Note 1: When the power is on, flip the MB switch ON (UP position) before plugging/unplugging the circuit card.
Note 2: When using this card, set the SW2 switch on the PN-CP00/PN-CP00-B/PN-CP03 (MP) as follows.
SW2-2: OFF
SW2-3: ON
Note 3: When using this card for providing a master office clock signal, set the SW0 switch on the PN-CK00 and
the SW switch on the PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A mounted in PIM0 as fol-
lows.
•
PN-CK00 card
SW0-1: OFF
SW0-2: OFF
SW0-3: OFF
SW0-4: OFF
SW0-8: ON
•
PN-24DTA/PN-24DTA-A card
SW-1: OFF
•
PN-30DTC/PN-30DTC-A card
SW-1: OFF
SW-2: OFF
SW-2: OFF
Note 4: When using this card as a sub-master, set the SW0 switch on the PN-CK00 and the SW switch on the
PN-24DTA/PN-24DTA-A or the PN-30DTC/PN-30DTC-A as follows:
For 1.5MHz interface:
•
PN-CK00 card
SW0-1: OFF
SW0-2: ON
•
PN-24DTA/PN-24DTA-A card
SW-1: ON
SW-2: OFF
SW0-3: OFF
SW0-4: ON*
SW0-8: ON
* Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI
card is mounted in PIM0.
For 2MHz interface:
•
PN-CK00 card
SW0-1: ON
SW0-2: ON
SW0-3: ON
SW0-4: ON*
SW0-8: ON
•
PN-30DTC/PN-30DTC-A card
SW-1: ON
SW-2: OFF
* Set to ON, when more than one DTI card is mounted in PIM0, or set to OFF when only one DTI
card is mounted in PIM0.
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 71
Revision 2.1
PN-24DTA (DTI)
PN-24DTA (DTI)
1. Locations of Lamps, Switches, and Connectors
SENS
RUN
MB
SW
JPS
CRC
PCM
FRM
RMT
AIS
JPR1
JPR0
BL
PN-24DTA (DTI) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
CRC
PCM
FRM
RMT
Green
Red
Flashes at 120 IPM while this card is operating normally.
Lights when detecting Cyclic Redundancy Checking (CRC) errors.
Lights when detecting PCM signal loss.
Red
Red
Lights when detecting a Frame Alignment signal loss.
Red
Lights when receiving a Frame Alignment signal loss alarm from a distant office.
Lights when a pattern of consecutive “1” bits is received. The distant office transmits this
signal for a loop-back test.
AIS
Red
Red
B channel status
ON
OFF
:
:
More than 10 channels are busy
All channels are idle
BL
Flash (60 IPM):Only one channel is busy
Flash (120 IPM):2 through 10 channels are busy
CHAPTER 4
Page 72
ND-45504 (E)
Revision 2.0
PN-24DTA (DTI)
CHECK
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
SENS
4 - F
Set the switch to match the AP Number (04 - 15) to be set by CM05.
(Rotary SW)
AP NO.
SW NO.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 - 3
Not used
UP
MB (Toggle SW)
For make-busy
ON
For normal operation
DOWN
Note 2
SW
Clock signal from a master office is sent to the PLO 0 in-
put on the MP card.
ON
OFF
ON
(Piano Key SW)
1
2
Clock signal from a master office is not sent to the PLO
0 input on the MP card.
OFF
Clock signal from a master office is sent to the PLO 1 in-
put on the MP card.
8
7
6
5
4
3
2
1
Clock signal from a master office is not sent to the PLO
1 input on the MP card.
OFF
ON
OFF
ON
Remote loop-back
3
4
5
6
For normal operation
Local loop-back (AIS send)
For normal operation
OFF
ON
ON
Set the equalizer according to the cable length
between the PBX and the MDF.
OFF
ON
SW-5 SW-6 SW-7
CABLE LENGTH
ON ON ON
0 - 40 m ( 0 - 131.2 ft.)
ON ON OFF 40 - 80 m (131.2 - 262.5 ft.)
ON OFF ON 80 - 120 m (262.5 - 394 ft.)
ON OFF OFF 120 - 160 m (394 - 525 ft.)
OFF ON ON 160 - 200 m (525 - 656 ft.)
OFF OFF OFF Signal is not sent
OFF
ON
7
8
OFF
OFF
Always set to OFF
ND-45504 (E)
CHAPTER 4
Page 73
Revision 2.0
PN-24DTA (DTI)
Switch Settings (Continued)
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
JPS (Jumper pin)
Neutral grounding on the transmitting line is not provid-
ed.
Right
Left
Neutral grounding on the transmitting line is provided.
JPR0 (Jumper pin)
Neutral grounding on the receiving line is not provided.
Up
Neutral grounding on the receiving line is provided.
Down
JPR1 (Jumper pin)
Line impedance : 110 ohms
Line impedance : 100 ohms
Right
Left
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the intended switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Note 3:
Set SW-1 and SW-2 as follows:
DTI0
DTI1
DTI2
DTI3
DTI4
NO. OF DTI
SW
REMARKS
SW SW SW SW SW SW SW SW SW SW
-1 -2 -1 -2 -1 -2 -1 -2 -1 -2
CONDITIONS
When one DTI is
provided
The MP card receives the clock
signal from DTI0 at its PLO0 in-
put.
ON OFF
When more than one
DTI is provided
The MP card receives the clock
signal from DTI0 at its PLO0 in-
put under normal conditions.
ON OFF OFF ON OFF OFF OFF OFF OFF OFF Should a clock failure occur with
DTI0, the MP card switches to the
PLO1 input, which gets clock
from DTI1.
Note 4:
When the PBX is the master office, set the SW-1 and SW-2 on all the DTI cards mounted in PIM0 to
“OFF”.
CHAPTER 4
Page 74
ND-45504 (E)
Revision 2.0
PN-24DTA-A (DTI)
PN-24DTA-A (DTI)
1. Location of Lamps, Switches, and Connectors
[When Card Issue No. is before 5A]
[When Card Issue No. is after 5B]
SENS
RUN
MB
SENS
RUN
MB
SW
SW
AISS
AISS
MAS
CRC
CRC
PCM
FRM
AIS
PCM
MAS
FRM
RMT
RMT
BL
JPR1
JPR0
JPS
JPR1
JPR0
JPS
AIS
BL
PN-24DTA-A (DTI) Card
Lamp Indications
2. Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
CRC
PCM
FRM
RMT
Green
Red
Flashes at 120 IPM while this card is operating normally.
Lights when detecting Cyclic Redundancy Checking (CRC) errors.
Lights when detecting PCM signal loss.
Red
Red
Lights when detecting a Frame Alignment signal loss.
Red
Lights when receiving a Frame Alignment signal loss alarm from a distant office.
Lights when a pattern of consecutive “1” is received. The distant office transmits this signal
for a loop-back test.
AIS
Red
Red
B channel status
ON
OFF
:
:
More than 10 channels is busy
All channels are idle
BL
Flash (60 IPM):Only one channel is busy
Flash (120 IPM):2 through 10 channels are busy
ND-45504 (E)
CHAPTER 4
Page 75
Revision 2.0
PN-24DTA-A (DTI)
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
SENS
4 ~ F
Set the switch to match the AP Number (04 ~ 15) to be set by CM05.
(Rotary SW)
AP NO.
SW NO.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
Not used
UP
Note 1
0 ~ 3
MB (Toggle SW)
For make-busy
ON
For normal operation
DOWN
Note 2
Clock signal from a master office is sent to the PLO 0 in-
put on the MP card.
ON
OFF
ON
1
2
Clock signal from a master office is not sent to the PLO
0 input on the MP card.
Clock signal from a master office is sent to the PLO 1 in-
put on the MP card.
SW
(Piano Key SW)
Clock signal from a master office is not sent to the PLO
1 input on the MP card.
OFF
ON
OFF
Remote loop-back
3
4
5
6
8
7
6
5
4
3
2
1
For normal operation
Local loop-back (AIS send)
For normal operation
OFF
ON
OFF
Set the equalizer according to the cable length between
the PBX and the MDF.
ON
OFF
SW-5
SW-6
SW-7
CABLE LENGTH
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON 0 - 40 m ( 0 - 131.2 ft.)
OFF 40 - 80 m (131.2 - 262.5 ft.)
ON 80 - 120 m (262.5 - 394 ft.)
OFF 120 - 160 m (394 - 525 ft.)
ON 160 - 200 m (525 - 656 ft.)
OFF Signal is not sent
7
8
OFF
ON
OFF
Always set to ON
CHAPTER 4
Page 76
ND-45504 (E)
Revision 2.0
PN-24DTA-A (DTI)
CHECK
Switch Settings (Continued)
SETTING
SWITCH
NAME
SWITCH
FUNCTION
NUMBER POSITION
JPS (Jumper pin)
JPR0 (Jumper pin)
JPR1 (Jumper pin)
AISS (Jumper pin)
MAS (Jumper pin)
Neutral grounding on the transmitting line is not provid-
ed.
Right
Left
Right
Left
Neutral grounding on the transmitting line is provided.
Neutral grounding on the receiving line is provided.
Neutral grounding on the receiving line is not provided.
Line impedance : 110 ohms
Right
Left
Line impedance : 100 ohms
AIS signal is sent out when make-busy or power on.
AIS signal is not sent out when make-busy or power on.
When this card is used for factory testing.
When this card is used for normal operation.
Right
Left
Right
Left
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the intended switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
CHAPTER 4
Page 77
Revision 2.0
PN-24DTA-A (DTI)
Note 3: Set SW-1 and SW-2 as follows:
DTI0
DTI1
DTI2
DTI3
DTI4
No. of DTI
SW
REMARKS
SW- SW- SW- SW- SW- SW- SW- SW- SW- SW-
1
2
1
2
1
2
1
2
1
2
CONDITIONS
The MP card will receive the
clock signal from DTI0 at its
PLO0 input.
When one DTI is pro-
vided.
ON OFF
The MP card will receive the
clock signal from DTI0 at its
PLO0 input, under normal condi-
tions.
Should a clock failure occur with
DTI0, the MP card will switch to
the PLO1 input which gets clock
from DTI1.
When more than one
DTI is provided.
ON OFF OFF ON OFF OFF OFF OFF OFF OFF
Note 4:
When the PBX is the master office, set the SW1-1 and SW1-2 on all the DTI cards mounted in PIM0 to
“OFF”.
CHAPTER 4
Page 78
ND-45504 (E)
Revision 2.0
PN-30DTC/30DTC-A (DTI)
PN-30DTC/30DTC-A (DTI)
1. Locations of Lamps, Switches, and Connectors
SENS
RUN
MB
SW
PCM
FRM
MFRM
RMT
MRMT
AIS
JPS
JPR
BL
JP
PN-30DTC/30DTC-A (DTI) Card
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 78-1
Revision 2.1
PN-30DTC/30DTC-A (DTI)
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
RUN
COLOR
Green
Red
Flashes at 120 IPM when this card is normally operating.
Lights when detecting PCM signal loss.
PCM
FRM
Red
Lights when detecting Frame Alignment signal loss.
Lights when detecting Multi-Frame Alignment signal loss on time slot 16.
MFRM
Red
Lights when receiving an alarm because Frame Alignment signal loss has been
detected at the distant office.
RMT
Red
Red
Lights when receiving an alarm because Multi-Frame Alignment signal loss has
been detected at the distant office.
MRMT
Lights when indicating that the pattern of consecutive “1” is being received. (The
distant office transmits this signal for a loop-back test).
AIS
BL
Red
Red
B channel status
ON
OFF
: More than10 channels are busy
: All channels are idle
Flash (60 IPM) : Only one channel is busy
Flash (120 IPM) : 2 to 10 channels are busy
CHAPTER 4
Page 78-2
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
PN-30DTC/30DTC-A (DTI)
3. Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
SENS
4 ~ F
Set the switch to match the AP Number (04-15) as set by CM05.
(Rotary SW)
AP NO.
SW NO.
04 05 06 07 08 09 10 11 12 13 14 15
0
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 ~ 3
Not used
UP
MB (Toggle SW)
For make-busy
ON
For normal operation
DOWN
Note 2
SW
Clock signal from master office is sent to PLO 0 on
the MP card.
ON
OFF
ON
1
(Piano Key SW)
Clock signal from master office is not sent to
PLO 0 on the MP card.
Note 3
OFF
8
7
6
5
4
3
2
1
Clock signal from master office is sent to PLO 1 on
the MP card.
2
Clock signal from master office is not sent to
PLO 1 on the MP card.
Note 3
OFF
ON
OFF
ON
Remote loop-back
3
4
5
For normal operation
Local loop-back (AIS send)
For normal operation
ON
OFF
ON
Transmission line cable: Coaxial (75 Ω)
Note 4
Transmission line cable: Twisted-pair (120 Ω)
Always set to OFF
OFF
OFF
OFF
ON
6
7
8
Always set to ON
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 78-3
Revision 2.1
PN-30DTC/30DTC-A (DTI)
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
JPS
(Jumper pin)
Balanced transmission
(For twisted-pair cable)
UP
TA is grounded on the transmission line
DOWN
UP
(For coaxial cable)
Note 4
JPR
(Jumper pin)
Balanced transmission
(For twisted-pair cable)
RA is grounded on the transmission line
(For coaxial cable)
DOWN
RIGHT
LEFT
JP
Line impedance: 75 ohms
(Jumper pin)
(For coaxial cable)
Note 4
Line impedance: 120 ohms
(For twisted-pair cable)
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1: Set the groove on the switch knob to the intended switch position.
Note 2: When the power is on, set the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
CHAPTER 4
Page 78-4
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
PN-30DTC/30DTC-A (DTI)
Note 3: Set SW-1 and SW-2 as follows.
No. of DTI
SW
DTI 0
DTI 1
DTI 2
DTI 3
REMARKS
SW-1 SW-2 SW-1 SW-2 SW-1 SW-2 SW-1 SW-2
CONDITIONS
The MP card will receive the clock
signal from DTI 0 at its PLO 0 input.
When one DTI is provided. ON
OFF
OFF
The MP card will receive the clock
signal from DTI 0 at its PLO 0 input,
under normal conditions.
When more than one DTI
ON
OFF
ON
OFF
OFF
OFF
OFF Should a clock failure occur on
DTI 0, the MP card will automatical-
ly switch to the PLO 1 input, and so
derive the clock from DTI 1.
is provided.
Note 4: Coaxial cable connection to the PN-30DTC/30DTC-A is not available in the U.S.
ND-45504 (E)
Addendum-001
JULY, 1998
CHAPTER 4
Page 78-5
Revision 2.1
This page is for your notes.
CHAPTER 4
Page 78-6
Revision 2.1
ND-45504 (E)
Addendum-001
JULY, 1998
PN-ME00 (EXTMEM)
PN-ME00 (EXTMEM)
1. Locations of Lamps, Switches, and Connectors
JP0
SENS
RUN
JP2
MB
WP
BAT
CN0
PN-ME00 (EXTMEM) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
WP
Green
Red
Flashes at 120 IPM while this circuit card is operating normally.
Lights when the RAM is being accessed.
Lights indicating the status (Write Protect Switch status and the battery voltage
status) of the SRAM card on this circuit card.
WRITE PROTECT
SWITCH STATUS
BATTERY VOLTAGE
STATUS
LAMP STATUS
BAT
Red
On
Protect On
OK
Flash (60 IPM)
Flash (120 IPM)
Off
Protect Off
Protect On
Protect Off
Needs to be replaced
Needs to be replaced
OK
ND-45504 (E)
CHAPTER 4
Page 79
Revision 2.0
PN-ME00 (EXTMEM)
How to Handle the SRAM Card
■ Mounting the SRAM Card
① Slide the lock switch downward (Lock Release), then remove the battery case from the SRAM card.
② Mount the battery on the battery case, then insert the battery case into the SRAM card.
③ Slide the lock switch upward (Lock).
④ Mount the SRAM card in the PN-ME00 card.
⑤ Slide the write protect switch downward (Active).
BATTERY CASE LOCK SWITCH
WRITE PROTECT SWITCH
DOWNWARD
UPWARD
L O C K
ACTIVE
LOCK
PROTECT
LOCK RELEASE
FRONT
Front View of the SRAM Card
CHAPTER 4
ND-45504 (E)
Page 80
Revision 2.0
PN-ME00 (EXTMEM)
■
Removing the SRAM Card
➀ Push the card slot bar of the PN-ME00 card.
➁ Remove the SRAM card.
PN-ME00
PUSH
SRAM
Removing the SRAM Card
■ Replacing the SRAM Battery
CAUTION
To prevent loss of memory on an active system, the battery must be replaced when the SRAM card is installed on
the PN-ME00, and the PN-ME00 is installed in the system. Also, power to the system must be “ON”.
➀ Slide the lock switch downward (Lock Release), then remove the battery case from the SRAM card.
➁ Replace the battery, then insert the battery case into the SRAM card.
➂ Slide the lock switch upward (Lock).
ND-45504 (E)
CHAPTER 4
Page 81
Revision 2.0
PN-ME00 (EXTMEM)
PN-ME00
REMOVE THE
BATTERY CASE
LITHIUM BATTERY:
BR2325 OR CR2325
Replacing the SRAM Battery
CHAPTER 4
Page 82
ND-45504 (E)
Revision 2.0
PN-ME00 (EXTMEM)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
FUNCTION
CHECK
SENSE
(Rotary SW)
4 - F
Set the switch to match the AP Number (04 - 15) to be set by
CM05.
AP NO.
SW NO.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 - 3
Not used
For make-busy
MB(Toggle SW)
UP
For normal operation
ON
DOWN
Note 2
JP0 (Jumper pin)
For normal operation
UP
Front
Note 3
JP2 (Jumper pin)
For normal operation
UP
Front
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the desired switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Note 3:
Do not touch the JP0. If the jumper is pulled off, the data in the memory of the ME00 card is cleared.
ND-45504 (E)
CHAPTER 4
Page 83
Revision 2.0
PN-4RSTB (MFR)
PN-4RSTB (MFR)
1. Locations of Lamps, Switches and Connectors
SENS
RUN
MB
SW
OPE3
OPE2
OPE1
OPE0
PN-4RSTB (MFR) Card
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
RUN
Green
Flashes at 120 IPM while the circuit card is operating normally.
• Lights when the corresponding circuit is in use.
OPE
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
CHAPTER 4
Page 84
ND-45504 (E)
Revision 2.0
PN-4RSTB (MFR)
CHECK
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
SENS
(Rotary SW)
Set the switch to match the AP Number (04 - 15) to be set by CM05.
4 - F
AP NO.
SW NO.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 - 3
Not used
UP
MB (Toggle SW)
For make-busy
For normal operation
ON
DOWN
Note 2
SW
ON
OFF
ON
For make-busy No. 0 circuit
For normal operation
1
2
3
4
(Piano Key SW)
For make-busy No. 1 circuit
For normal operation
OFF
OFF
ON
8
7
6
5
For make-busy No. 2 circuit
For normal operation
OFF
ON
For make-busy No. 2 circuit
For normal operation
4
3
2
1
OFF
OFF
OFF
OFF
ON
5
6
7
8
Not used
ON
Always set to ON
Note 1:
Note 2:
Set the groove on the switch knob onto the desired switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
CHAPTER 4
Page 85
Revision 2.0
PN-4RSTC (CIR)
PN-4RSTC (CIR)
1. Locations of Lamps, Switches and Connectors
SENSE
RUN
MB
SW1
BL3
BL2
BL1
BL0
JP0
PN-4RSTC (CIR) Card
Lamp Indications
2. Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
Green
Red
Flashes at 120 IPM while the circuit card is operating normally.
Lights when receiving a CALLER ID (CLASS SM) signal.
BL0-3
CHAPTER 4
Page 86
ND-45504 (E)
Revision 2.0
PN-4RSTC (CIR)
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
4 - F
Set the switch to match the AP Number (04 - 15) to be set by CM05.
(Rotary SW)
AP NO.
SW NO.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
0 - 3
Not used
Note 1
MB(Toggle SW)
UP
For make-busy
ON
For normal operation
DOWN
Note 2
SW1
(Piano Key SW)
ON
OFF
ON
For make-busy No. 0 circuit
For normal operation
1
2
3
4
For make-busy No. 1 circuit
For normal operation
OFF
OFF
ON
4
3
2
1
For make-busy No. 2 circuit
For normal operation
OFF
ON
For make-busy No. 3 circuit
For normal operation
ON
OFF
JP0 (Jumper pin)
For normal operation
Right
Note 1:
Note 2:
Set the groove on the switch knob onto the desired switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
CHAPTER 4
Page 87
Revision 2.0
PN-SC00 (CCH)
PN-SC00 (CCH)
1. Locations of Lamps, Switches and Connectors
SW1
SENS
RUN
MB
SW0
LC
LPB
RS
PN-SC00 (CCH) Card
Lamp Indications
2. Lamp Indications
LAMP NAME
COLOR
FUNCTION
RUN
Green
Flashes at 120 IPM while this card is operating normally.
Lights when communications are normally ongoing with the common signalling channel
data links connected.
LC
Green
Green
LPB
Lights when a loop-back test is in progress.
CHAPTER 4
Page 88
ND-45504 (E)
Revision 2.0
PN-SC00 (CCH)
CHECK
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
4 - F
Set the switch to match the AP Number (04 - 15) to be set by CM05.
SENS
(Rotary SW)
AP NO.
SW NO.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 - 3
Not used
MB(Toggle SW)
UP
For make-busy
For normal operation
ON
DOWN
Note 2
SW0
(Piano Key SW)
ON
OFF
ON
Loop-back test
1
2
For normal operation
Analog interface
Digital interface
OFF
OFF
4
3
2
1
RS-232C RTS signal (to MODEM) ON
Note 3
ON
3
4
OFF
ON
RS-232C RTS signal (to MODEM) OFF
Always set to ON
ON
ND-45504 (E)
CHAPTER 4
Page 89
Revision 2.0
PN-SC00 (CCH)
Switch Settings (Continued)
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
• Common channel signalling data transmission speed
(For Digital Interface)
ON
1
OFF
TRANSMISSION SW
SW
1-2
SW
1-3
SW
1-4
SW
1-5
ON
SPEED
1-1
2
48Kbps ¨
48Kbps ¦
56Kbps
64Kbps
ON ON OFF OFF ON
ON ON ON OFF ON
ON ON OFF ON ON
ON ON ON ON ON
OFF
ON
3
SW1(Dip SW)
OFF
• Common channel signalling data transmission speed
(For Analog Interface)
ON
ON
4
1 2 3 4 5 6 7 8
Set switches (SW1-1 - SW1-5) to OFF.
OFF
ON
5
OFF
A-Law
ON
6
µ-law
OFF
Always set to OFF
Always set to OFF
7
8
OFF
OFF
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the desired switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
Note 3:
Note 4:
This setting is available when SW0-2 is set to ON (Analog Interface).
The followimg two kinds of rate adaptation method are available when using 48 Kbps data transmis-
sion. The rate adaptation method must be set to match the rate adaptation of the master office.
SW1-3: OFF
SW1-3: ON
1
2
48 Kbps
48 Kbps
1
1
1
1
Data
Data
CHAPTER 4
Page 90
ND-45504 (E)
Revision 2.0
PN-SC01 (DCH)
PN-SC01 (DCH)
1. Locations of Lamps, Switches and Connectors
SW1
SENS
RUN
MB
SW0
LC
LPB
PN-SC01 (DCH) Card
Lamp Indications
2. Lamp Indications
LAMP NAME
COLOR
FUNCTION
Flashes at 120 IPM while this card is operating normally.
RUN
LC
Green
Green
Green
Lights when communications are normally ongoing with the D channel data links connected.
Not used.
LPB
ND-45504 (E)
CHAPTER 4
Page 91
Revision 2.0
PN-SC01 (DCH)
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENS
4 - F
Set the switch to match the AP Number (04 - 15) to be set by CM05.
(Rotary SW)
AP NO.
SW NO.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 - 3
Not used
UP
MB(Toggle SW)
For make-busy
ON
For normal operation
DOWN
Note 2
SW0
(Piano Key SW)
OFF
ON
AT&T Interface
1
Northern Telecom Interface
No deletion
OFF
ON
OFF
2
3
Delete the first three digits of all 011 International Calls.
Always set to OFF
4
3
2
1
OFF
4
Always set to ON
ON
ON
SW1 (Dip SW)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
1
2
3
4
5
6
7
8
Always set to OFF
Always set to OFF
Always set to OFF
Always set to OFF
Always set to OFF
Always set to OFF
Always set to OFF
Always set to OFF
ON
1 2 3 4 5 6 7 8
CHAPTER 4
Page 92
ND-45504 (E)
Revision 2.0
PN-SC01 (DCH)
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob onto the intended switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
CHAPTER 4
Page 93
Revision 2.0
PN-SC02 (ICH)
PN-SC02 (ICH)
1. Locations of Lamps, Switches, and Connectors
SENS
RUN
MB
DOPE1
DOPE0
SW0
PN-SC02 (ICH) Card
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
RUN
Green
Flashes at 120 IPM while this card is operating normally.
ON: No. 0 circuit D channel link is connected.
OFF: No. 0 circuit D channel link is not connected.
DOPE0
DOPE1
Green
Green
ON: No. 1 circuit D channel link is connected.
OFF: No. 1 circuit D channel link is not connected.
CHAPTER 4
Page 94
ND-45504 (E)
Revision 2.0
PN-SC02 (ICH)
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
SENS
4 - F
Set the switch to match the AP Number (04 - 15) to be set by CM05.
(Rotary SW)
AP NO.
SW NO.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 - 3
Not used
MB (Toggle SW)
UP
For make-busy
ON
For normal operation
DOWN
Note 2
SW0
(Piano Key SW)
1
2
3
Always set to OFF
Always set to OFF
Always set to OFF
Always set to ON
OFF
OFF
OFF
OFF
4
3
2
1
4
ON
ON
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the desired switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
CHAPTER 4
Page 95
Revision 2.0
PN-SC03 (ICH)
PN-SC03 (ICH)
1. Locations of Lamps, Switches, and Connectors
SENSE
RUN
MB
DOPE7
DOPE6
DOPE5
DOPE4
DOPE3
DOPE2
DOPE1
DOPE0
PN-SC03 (ICH) Card
2. Lamp Indications
Lamp Indications on ICH Card
FUNCTION
LAMP NAME
COLOR
RUN
Green
Green
Green
Green
Green
Green
Green
Green
Green
Flashes at 120 IPM while the card is operating normally.
Lights when No.7 circuit D channel link is connected.
Lights when No.6 circuit D channel link is connected.
Lights when No.5 circuit D channel link is connected.
Lights when No.4 circuit D channel link is connected.
Lights when No.3 circuit D channel link is connected.
Lights when No.2 circuit D channel link is connected.
Lights when No.1 circuit D channel link is connected.
Lights when No.0 circuit D channel link is connected.
DOPE7
DOPE6
DOPE5
DOPE4
DOPE3
DOPE2
DOPE1
DOPE0
CHAPTER 4
Page 96
ND-45504 (E)
Revision 2.0
PN-SC03 (ICH)
(3) Switch Settings
Switch Settings on ICH Card
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
SENSE
4 ~ F
Set the switch to match the AP Number (04 ~ 15) to be set by CM05.
(Rotary SW)
AP No.
SW No.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 ~ 3
Not used
UP
MB (Toggle SW)
For make-busy
ON
For normal operation
DOWN
Note 2
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the intended switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
CHAPTER 4
Page 97
Revision 2.0
PN-SC03 (CSH)
PN-SC03 (CSH)
1. Locations of Lamps, Switches, and Connectors
SENSE
RUN
MB
DOPE7
DOPE6
DOPE5
DOPE4
DOPE3
DOPE2
DOPE1
DOPE0
PN-SC03 (CSH) Card
CHAPTER 4
Page 98
ND-45504 (E)
Revision 2.0
PN-SC03 (CSH)
(2) Lamp Indications
Lamp Indications on CSH Card
FUNCTION
LAMP NAME
COLOR
RUN
Green
Green
Green
Green
Green
Green
Green
Green
Green
Flashes at 120 IPM while the card is operating normally.
Lights when No.7 circuit D channel link is connected.
Lights when No.6 circuit D channel link is connected.
Lights when No.5 circuit D channel link is connected.
Lights when No.4 circuit D channel link is connected.
Lights when No.3 circuit D channel link is connected.
Lights when No.2 circuit D channel link is connected.
Lights when No.1 circuit D channel link is connected.
Lights when No.0 circuit D channel link is connected.
DOPE7
DOPE6
DOPE5
DOPE4
DOPE3
DOPE2
DOPE1
DOPE0
3. Switch Settings
Switch Settings on CSH Card
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
SENSE
4 ~ F
Set the switch to match the AP Number (04 ~ 15) to be set by CM05.
(Rotary SW)
AP No.
SW No.
04 05 06 07 08 09 10 11 12 13 14 15
4
5
6
7
8
9
A
B
C
D
E
F
Note 1
0 ~ 3
Not used
UP
MB (Toggle SW)
For make-busy
ON
For normal operation
DOWN
Note 2
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note 1:
Note 2:
Set the groove on the switch knob to the intended switch position.
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit
card.
ND-45504 (E)
CHAPTER 4
Page 99
Revision 2.0
4. LAMP INDICATIONS AND SWITCH SETTINGS OF LINE/TRUNK CIRCUIT CARDS
Table 4-3 below shows the line/trunk circuit cards to be explained in this section.
Table 4-3 Table of Line /Trunk Circuit Cards
EXISTENCE OF
EXISTENCE OF
EXTRACTION/INSER-
NAME
(FUNCTIONAL NAME)
REFERENCE
PAGE
LAMPS
X: PROVIDED
SWITCHES
X: PROVIDED
TION WITH POWER ON
X: ALLOWED
— : NOT PROVIDED
— : NOT PROVIDED
: NOT ALLOWED
—
PN-2AMPA (AMP)
PN-AUCA (AUC)
PN-CFTA (CFT)
PN-4COTB (COT)
PN-4COTG (COT)
PN-2DATA (DAT)
PN-DK00 (DK)
X
X
X
X
X
X
—
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
—
—
X
—
—
—
—
—
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
101
102
103
104
105
106
108
109
110
111
112
113
114
115
116
117
118
121
124
125
126
129
130
131
133
—
—
—
—
—
—
—
—
—
—
X
PN-4DITB (DIT)
PN-2DLCB (DLC)
PN-2DLCC (DLC)
PN-2DLCN (DLC)
PN-4DLCA (DLC)
PN-4DLCD (DLC)
PN-4DLCF (DLC)
PN-4DLCM (DLC)
PN-4DLCQ (DLC)
PN-2DPCB (DPC)
PN-2ILCA (ILC)
PN-4LCD/4LCD-A (LC)
PN-4LCJ (LC)
X
—
—
X
PN-M03 (M03)
PN-2ODTA (ODT)
PN-8RSTA (PBR)
PN-TNTA (TNT)
PN-2CSIA (CSI)
—
—
X
X
CHAPTER 4
Page 100
ND-45504 (E)
Revision 2.0
PN-2AMPA (AMP)
PN-2AMPA (AMP)
1. Locations of Lamps, Switches and Connectors
BL1
BL0
PN-2AMPA (AMP) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the corresponding circuit is in use.
BL0, 1
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 101
Revision 2.0
PN-AUCA (AUC)
PN-AUCA (AUC)
1. Locations of Lamps, Switches and Connectors
BL1
BL0
CN1
PN-AUCA (AUC) Card
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
• Remains lit when the corresponding circuit is in use.
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
BL0, 1
Red
3. Switch Settings
This card has no switches.
CHAPTER 4
ND-45504 (E)
Page 102
Revision 2.0
PN-CFTA (CFT)
PN-CFTA (CFT)
1. Locations of Lamps, Switches and Connectors
BL1
PN-CFTA (CFT) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the card is in use.
BL0
Red
• Flashes (60 IPM) When the circuit on the card is in the make-busy state on the system data
for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 103
Revision 2.0
PN-4COTB (COT)
PN-4COTB (COT)
1. Locations of Lamps, Switches and Connectors
BL3
BL2
BL1
BL0
CN1
PN-4COTB (COT) Card
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
• Remains lit when the corresponding circuit is in use.
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
BL0 - 3
Red
3. Switch Settings
This card has no switches.
CHAPTER 4
ND-45504 (E)
Page 104
Revision 2.0
PN-4COTG (COT)
PN-4COTG (COT)
1. Locations of Lamps, Switches and Connectors
BL3
BL2
BL1
BL0
CN1
PN-4COTG (COT) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the corresponding circuit is in use.
BL0 - 3
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 105
Revision 2.0
PN-2DATA (DAT)
PN-2DATA (DAT)
1. Locations of Lamps, Switches and Connectors
BL1
BL0
SW
PN-2DATA (DAT) Card
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
• Remains lit when the corresponding circuit is in use.
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
BL0, 1
Red
CHAPTER 4
Page 106
ND-45504 (E)
Revision 2.0
PN-2DATA (DAT)
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
Data write into the No.1 circuit is disabled.
Data write into the No.1 circuit is enabled.
Data write into the No.1 circuit is disabled.
Data write into the No.1 circuit is enabled.
ON
SW
SW-0
(Piano Key SW)
ON
OFF
SW1
SW0
ON
SW-1
OFF
OFF
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
ND-45504 (E)
CHAPTER 4
Page 107
Revision 2.0
PN-DK00 (DK)
PN-DK00 (DK)
1. Locations of Lamps, Switches and Connectors
PN-DK00 (DK) Card
2. Lamp Indications
This card has no indicator lamps.
3. Switch Settings
This card has no switches.
CHAPTER 4
ND-45504 (E)
Page 108
Revision 2.0
PN-4DITB (DIT)
PN-4DITB (DIT)
1. Locations of Lamps, Switches, and Connectors
BL3
BL2
BL1
BL0
PN-4DITB (DIT) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
BL0 ~ 3
COLOR
FUNCTION
• Light when the corresponding circuit is in use.
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or
the system data for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 109
Revision 2.0
PN-2DLCB (DLC)
PN-2DLCB (DLC)
1. Locations of Lamps, Switches and Connectors
BL1
BL0
CN0
PN-2DLCB (DLC) Card
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
• Remains lit when the corresponding circuit is in use.
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
BL0 , 1
Red
3. Switch Settings
This card has no switches.
CHAPTER 4
ND-45504 (E)
Page 110
Revision 2.0
PN-2DLCC (DLC)
PN-2DLCC (DLC)
1. Locations of Lamps, Switches and Connectors
BL1
BL0
PN-2DLCC (DLC) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the corresponding circuit is in use.
BL0 , 1
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 111
Revision 2.0
PN-2DLCN (DLC)
PN-2DLCN (DLC)
1. Locations of Lamps, Switches and Connectors
BL1
BL0
CN0
PN-2DLCN (DLC) Card
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
• Remains lit when the corresponding circuit is in use.
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
BL0, 1
Red
3. Switch Settings
This card has no switches.
CHAPTER 4
ND-45504 (E)
Page 112
Revision 2.0
PN-4DLCA (DLC)
PN-4DLCA (DLC)
1. Locations of Lamps, Switches and Connectors
BL3
BL2
BL1
BL0
PN-4DLCA (DLC) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the corresponding circuit is in use.
BL0 - 3
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 113
Revision 2.0
PN-4DLCD (DLC)
PN-4DLCD (DLC)
1. Locations of Lamps, Switches and Connectors
BL3
BL2
BL1
BL0
PN-4DLCD (DLC) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the corresponding circuit is in use
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the
system data for this card is not assigned
BL0-3
Red
3. Switch Settings
This card has no switches.
CHAPTER 4
ND-45504 (E)
Page 114
Revision 2.0
PN-4DLCF (DLC)
PN-4DLCF (DLC)
1. Locations of Lamps, Switches and Connectors
BL3
BL2
BL1
BL0
CN1
PN-4DLCF (DLC) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the corresponding circuit is in use.
BL0 - 3
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 115
Revision 2.0
PN-4DLCM (DLC)
PN-4DLCM (DLC)
1. Locations of Lamps, Switches and Connectors
BL3
BL2
BL1
BL0
PN-4DLCM (DLC) Card
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
• Remains lit when the corresponding circuit is in use.
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
BL0-3
Red
3. Switch Settings
This card has no switches.
CHAPTER 4
ND-45504 (E)
Page 116
Revision 2.0
PN-4DLCQ (DLC)
PN-4DLCQ (DLC)
1. Locations of Lamps, Switches and Connectors
BL3
BL2
BL1
BL0
PN-4DLCQ (DLC) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the corresponding circuit is in use.
BL0-3
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 117
Revision 2.0
PN-2DPCB (DPC)
PN-2DPCB (DPC)
1. Location of Lamps, Switches and Connectors
RSC1
SDT1
RDR1
CDI1
BL1
LB11
LB12
BL0
LB01
LB02
RSC0
SDT0
RDR0
CDI0
SW1
SW0
XCN1
XCN0
RS1
RS0
PN-2DPCB (DPC) Card
CHAPTER 4
Page 118
ND-45504 (E)
Revision 2.0
PN-2DPCB (DPC)
(2) Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME COLOR
ON: Ready for digital data transmission or the circuit is busy.
OFF: Fixed path is not connected.
BL0
Red
Flash (60IPM): Make-busy state or the system data for this card is not as-
signed.
Flash (120IPM): Fixed path is connected.
ON: Loop Back 1 is set.
OFF: Normally operating.
LB01
LB02
RSC0
SDT0
RDR0
CDI0
Red
Red
ON: Loop Back 2 is set.
OFF: Normally operating.
No. 0 Circuit
ON: RTS/C signal ON.
OFF: RTS/C signal OFF.
Green
Green
Green
Green
ON: TXD/T signal is “0”.
OFF: TXD/T signal is “1”.
ON: RXD/R signal is “0”.
OFF: RXD/R signal is “1”.
ON: DCD/I signal ON.
OFF: DCD/I signal OFF.
ON: Ready for digital data transmission or the circuit is busy.
OFF: Fixed path is not connected.
BL1
Red
Flash (60IPM): Make-busy state or the system data for this card is not as-
signed.
Flash (120IPM): Fixed path is connected.
ON: Loop Back 1 is set.
OFF: Normally operating.
LB11
LB12
RSC1
SDT1
RDR1
CDI1
Red
Red
ON: Loop Back 2 is set.
OFF: Normally operating.
No. 1 Circuit
ON: RTS/C signal ON.
OFF: RTS/C signal OFF.
Green
Green
Green
Green
ON: TXD/T signal is “0”.
OFF: TXD/T signal is “1”.
ON: RXD/R signal is “0”.
OFF: RXD/R signal is “1”.
ON: DCD/I signal ON.
OFF: DCD/I signal OFF.
ND-45504 (E)
CHAPTER 4
Page 119
Revision 2.0
PN-2DPCB (DPC)
(3) Switch Settings
Switch Settings
SWITCH
NUMBER POSITION
SETTING
SWITCH NAME
FUNCTION
Loop Back 1 ON
CHECK
SW1
(Piano Key SW)
ON
1
Loop Back 1 OFF
OFF
No. 0
Circuit
ON
Loop Back 2 ON
OFF
2
Loop Back 2 OFF
OFF
4
3
2
1
ON
Loop Back 1 ON
3
Loop Back 1 OFF
OFF
No. 1
Circuit
ON
Loop Back 2 ON
ON
4
Loop Back 2 OFF
OFF
SW0 (Dip SW)
ON
Forcibly turning the DTR signal to ON
The DTR signal from DTE goes through the card
Forcibly turning the RTS/C signal to ON
The RTS/C signal from DTE goes through the card
Not used
1
OFF
1 2 3 4 5 6 7 8
ON
ON
2
No. 0
Circuit
OFF
3
4
OFF
ON
V.11 (X.21) interface
OFF
ON
V.24/V.28 (RS-232C) interface
Forcibly turning the DTR signal to ON
The DTR signal from DTE goes through the card
Forcibly turning the RTS/C signal to ON
The RTS/C signal from DTE goes through the card
Not used
5
OFF
ON
6
7
8
No. 1
Circuit
OFF
OFF
ON
V.11 (X.21) interface
OFF
V.24/V.28 (RS-232C) interface
The figure in the SWITCH NAME column and the position in
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure
and , the setting of the switch varies with the system concerned.
in the SETTING POSITION col-
Note: When the power is on, disconnect the cables before unplugging the circuit card, and connect the cables af-
ter plugging the circuit card.
CHAPTER 4
Page 120
ND-45504 (E)
Revision 2.0
PN-2ILCA (ILC)
PN-2ILCA (ILC)
1. Locations of Lamps, Switches, and Connectors
ACT1
PAL1
LPB1
B21
B11
ACT0
PAL0
LPB0
B20
B10
SW1
SW0
PN-2ILCA (ILC) Card
ND-45504 (E)
CHAPTER 4
Page 121
Revision 2.0
PN-2ILCA (ILC)
(2) Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
ON: Normally operating.
OFF: Not operating.
ACT1
Green
ON: Line is short-circuiting.
OFF: Normally operating.
PAL1
LPB1
B21
Red
Red
No. 1 Circuit OFF: Not used.
ON: B2 channel is in use.
OFF: B2 channel is idle.
Green
ON: B1 channel is in use.
OFF: B1 channel is idle.
B11
Green
Green
ON: Normally operating.
OFF: Not operating.
ACT0
ON: Line is short-circuiting.
OFF: Normally operating.
PAL0
LPB0
B20
Red
Red
No. 0 Circuit OFF: Not used.
ON: B2 channel is in use.
OFF: B2 channel is idle.
Green
ON: B1 channel is in use.
OFF: B1 channel is idle.
B10
Green
CHAPTER 4
Page 122
ND-45504 (E)
Revision 2.0
PN-2ILCA (ILC)
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
SW1
(Piano Key SW)
Always set to OFF
Always set to OFF
Always set to OFF
Always set to OFF
1
2
3
OFF
OFF
OFF
OFF
4
3
2
1
4
1
2
3
4
OFF
ON
SW0
(Piano Key SW)
No. 0 Circuit Terminating register is provided.
ON
OFF
ON
(Receiving)
Terminating register is not provided.
OFF
No. 0 Circuit Terminating register is provided.
4
3
2
1
(Sending)
OFF
ON
Terminating register is not provided.
No. 1 Circuit Terminating register is provided.
(Receiving)
OFF
ON
Terminating register is not provided.
ON
No. 1 Circuit Terminating register is provided.
(Sending)
OFF
Terminating register is not provided.
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
ND-45504 (E)
CHAPTER 4
Page 123
Revision 2.0
PN-4LCD/4LCD-A (LC)
PN-4LCD/4LCD-A (LC)
1. Locations of Lamps, Switches and Connectors
BL3
BL2
BL1
BL0
PN-4LCD/4LCD-A (LC) Card
2. Lamp Indications
Lamp Indications
FUNCTION
LAMP NAME
COLOR
• Remains lit when the corresponding circuit is in use.
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
BL0-3
Red
3. Switch Settings
This card has no switches.
CHAPTER 4
ND-45504 (E)
Page 124
Revision 2.0
PN-4LCJ (LC)
PN-4LCJ (LC)
1. Locations of Lamps, Switches and Connectors
BL3
BL2
BL1
BL0
PN-4LCJ (LC) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the corresponding circuit is in use.
BL0 - 3
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 125
Revision 2.0
PN-M03 (M03)
PN-M03 (M03)
1. Locations of Lamps, Switches and Connectors
OPRS
OPER
SW0
OPSD
OPE
RS
SD
RD
CD
ER
DR
CS
SELX21
X21
SELCN0
CN0
JP1B
JP1A
V35
PN-M03 (M03) Card
CHAPTER 4
Page 126
ND-45504 (E)
Revision 2.0
PN-M03 (M03)
(2) Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
ON: This card is normally connected to the PN-2DPCB.
OFF: This card is abnormally connected to the PN-2DPCB.
OPE
Green
Green
Green
Green
Green
Green
Green
Green
ON: RTS signal is ON.
OFF: RTS signal is OFF.
RS
SD
RD
CD
ER
DR
CS
ON: TXD signal is “0” (Space condition).
OFF: TXD signal is “1” (Mark condition).
ON: RXD signal is “0” (Space condition).
OFF: RXD signal is “1” (Mark condition).
ON: DCD signal is ON.
OFF: DCD signal is OFF.
ON: DTR signal is ON.
OFF: DTR signal is OFF.
ON: DSR signal is ON.
OFF: DSR signal is OFF.
ON: CTS signal is ON.
OFF: CTS signal is OFF.
ON: Connecting to the PN-2DPCB is available.
OFF: Connecting to the PN-2DPCB is not available.
SELX21
SELCN0
Green
Green
Not used.
ND-45504 (E)
CHAPTER 4
Page 127
Revision 2.0
PN-M03 (M03)
(3) Switch Settings
Switch Settings
SWITCH
NAME
SWITCH
NUMBER POSITION
SETTING
FUNCTION
CHECK
SW0 (Dip SW)
Always set to OFF.
Not used.
1
2
OFF
OFF
2
1
ON
JP1A (Jumper pin)
TXC(2) signal is sent out.
Right
Left
TXC(2) signal is inputted.
Note
JP1B (Jumper pin)
TXC(2) signal is sent out.
Right
Left
TXC(2) signal is inputted.
Note
OPSD (Jumper pin)
Set the function of extending distance for TXD signal.
Right
Left
Cancel the function of extending distance for TXD sig-
nal.
OPRS (Jumper pin)
OPER (Jumper pin)
Set the function of extending distance for RTS signal.
Right
Left
Cancel the function of extending distance for RTS sig-
nal.
Set the function of extending distance for DTR signal.
Right
Left
Cancel the function of extending distance for DTR sig-
nal.
Note: The JP1A and JP1B must be set to the same position each other.
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
CHAPTER 4
ND-45504 (E)
Page 128
Revision 2.0
PN-2ODTA (ODT)
PN-2ODTA (ODT)
1. Locations of Lamps, Switches and Connectors
BL1
BL0
CN1
PN-2ODTA (ODT) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
• Remains lit when the corresponding circuit is in use.
BL0, 1
Red
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system
data for this card is not assigned.
3. Switch Settings
This card has no switches.
ND-45504 (E)
CHAPTER 4
Page 129
Revision 2.0
PN-8RSTA (PBR)
PN-8RSTA (PBR)
1. Locations of Lamps, Switches and Connectors
PN-8RSTA (PBR) Card
2. Lamp Indications
This card has no indicator lamps.
3. Switch Settings
This card has no switches.
CHAPTER 4
ND-45504 (E)
Page 130
Revision 2.0
PN-TNTA (TNT)
PN-TNTA (TNT)
1. Location of Lamps, Switches and Connectors
SW
JACK1
JACK0
PN-TNTA (TNT) Card
2. Lamp Indications
This card has no lamps.
ND-45504 (E)
CHAPTER 4
Page 131
Revision 2.0
PN-TNTA (TNT)
3. Switch Settings
Switch Settings
SWITCH
NUMBER
SETTING
POSITION
SWITCH NAME
SW
FUNCTION
CHECK
Volume adjustment for No. 0 circuit
(Piano Key SW)
SWITCH NUMBER
VOLUME
OFF
1
2
1, 2
OFF
ON
OFF
ON
OFF
OFF
ON
–10 dB
–7 dB
–4 dB
–1 dB
4
3
2
1
ON
ON
Volume adjustment for No. 1 circuit
SWITCH NUMBER
VOLUME
3
4
3, 4
OFF
ON
OFF
ON
OFF
OFF
ON
–10 dB
–7 dB
–4 dB
–1 dB
ON
CHAPTER 4
Page 132
ND-45504 (E)
Revision 2.0
PN-2CSIA (CSI)
PN-2CSIA (CSI)
1. Locations of Lamps, Swtiches, and Connectors.
OPE
LB
B13
B12
B11
B10
B03
B02
B01
B00
DL1
DL0
PN-2CSIA (CSI) Card
2. Lamp Indications
Lamp Indications
LAMP NAME
COLOR
FUNCTION
OPE
LB
Green
Red
Lights when the corresponding circuit is in use.
Lights when a loop-back is in progress.
Not used (Flash [60IPM])
B13
Red
B channel status
ON : B2 channel of the No. 1 circuit is in use.
OFF : B2 channel of the No. 1 circuit is in idle.
Flash (60 IPM) : ZT is not connected to the No. 1 circuit.
ZT is in make-busy status.
B12
B11
Red
Red
B channel status
ON : B1 channel of the No. 1 circuit is in use.
OFF : B1 channel of the No. 1 circuit is in idle.
Flash (60 IPM) : ZT is not connected to the No. 1 circuit.
ZT is in make-busy status.
ND-45504 (E)
CHAPTER 4
Page 133
Revision 2.0
PN-2CSIA (CSI)
LAMP NAME
Lamp Indications
COLOR
FUNCTION
B channel status
ON : B0 channel of the No. 1 circuit is in use.
OFF : B0 channel of the No. 1 circuit is in idle.
Flash (60 IPM) : ZT is not connected to the No. 1 circuit.
ZT is in make-busy status.
B10
B03
B02
Red
Red
Red
Not used (Flash[60 IMP])
B channel status
ON : B2 channel of the No. 0 circuit is in use.
OFF : B2 channel of the No. 0 circuit is in idle.
Flash (60 IPM) : ZT is not connected to the No. 0 circuit.
ZT is in make-busy status.
B channel status
ON : B1 channel of the No. 0 circuit is in use.
OFF : B1 channel of the No. 0 circuit is in idle.
Flash (60 IPM) : ZT is not connected to the No. 0 circuit.
ZT is in make-busy status.
B01
B00
Red
Red
B channel status
ON : B0 channel of the No. 0 circuit is in use.
OFF : B0 channel of the No. 0 circuit is in idle.
Flash (60 IPM) : ZT is not connected to the No. 0 circuit.
ZT is in make-busy status.
3. Switch Settings
Switch Settings
SWITCH
NUMBER POSITION
SETTING
SWITCH NAME
FUNCTION
CHECK
DL0 (Rotary SW)
For normal operation
0
0 ~ F
Not used
1 ~ F
Note
DL1 (Rotary SW)
For normal operation
0
0 ~ F
Not used
1 ~ F
Note
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note: Set the groove on the switch knob to the intended switch position.
CHAPTER 4
Page 134
ND-45504 (E)
Revision 2.0
|