Lincoln Impinger Conveyor Ovens 1454 User Manual

SERVICE MANUAL  
(INTERNATIONAL)  
IMPINGER CONVEYOR OVENS  
MODEL 1421-000-E, 1454, 1455  
WITH PUSH BUTTON CONTROLS  
Lincoln Foodservice Products, LLC  
1111 North Hadley Road  
Fort Wayne, Indiana 46804  
United States of America  
Phone: (800) 374-3004  
U.S. Fax: (888) 790-8193 • Int’l Fax: (260) 436-0735  
Technical Service Hot Line  
(800) 678-9511  
1450ExpElect  
REV 1/30/08  
SEQUENCE OF OPERATION  
IMPINGER ADVANTAGE  
SERIAL NUMBER N28654 AND ABOVE  
(OVENS WITH PUSH BUTTON CONTROLS)  
MODEL 1454  
MODEL 1455  
220/380VAC  
240/415VAC  
50 HZ.  
50 HZ.  
3 PHASE  
3 PHASE  
POWER SUPPLY  
Electrical power is to be supplied to the oven by a five conductor  
service.  
Brown conductor is hot.  
Black conductor is hot.  
Black conductor is hot.  
Blue conductor is neutral.  
Green conductor is ground.  
CONTROL BOX AUTO  
COOL DOWN  
When the temperature in the control box reaches 120°F ± 3°F (48.9°C  
± 1.7°C), the cooling fan thermostat will switch power to the control  
box cooling fan. The thermostat will interrupt power to the cooling fan  
when the control box temperature falls to 100°F ± 3°F (37°C ± 1.7°C).  
Electrical power is permanently supplied through three 50 A fuses to  
the normally open contacts of the heat relay. Power is also supplied,  
through the 10 Amp motor and control fuse, through the normally  
closed control box hi-limit thermostat, to the normally open oven power  
switch. Power is also supplied to the control box cooling fan  
thermostat. Closing the oven power switch supplies line voltage to the  
main fan motor. Closing the oven power switch also supplies line  
voltage to the heat circuit and to the primary of the oven control  
transformer.  
MAIN FAN CIRCUIT  
HEAT CIRCUIT  
Closing the oven power switch supplies line voltage through the main  
fan air pressure switch, through the normally closed oven cavity hi-limit  
thermostat, to the oven control  
TEMPERATURE CONTROL Closing the oven power switch supplies line voltage to the primary of  
the control transformer and through the air pressure switch and oven  
cavity hi-limit, to the oven control. Secondary voltage, 24VAC, is  
supplied to the oven control. The oven control is set to desired  
temperature. The thermocouple will provide varying millivolts to the  
oven control. The oven control supplies line voltage to the heat  
contactor at intermittent intervals to maintain desired temperature. The  
display on the oven control will indicate when the heat contactor is  
energized.  
NOTE: The display also indicates oven temperature.  
CONVEYOR DRIVE  
Closing the oven power switch supplies line voltage to the conveyor  
motor and to the primary of the control transformer. Secondary  
voltage, 24VAC, is supplied to the oven control. Setting the oven  
control to the desired time outputs voltage, through a reversing switch,  
to the conveyor motor.  
NOTE: The conveyor system uses a hall effect sensor and magnet to  
prove operation of the conveyor motor. If the motor is not running,  
“BELT JAM” is indicated on the display.  
Impinger I -–Adv Digital – Electric Service Manual - International  
3
SCHEMATIC DIAGRAM  
MODEL 1421-000-E,  
SERIAL NUMBER N28654 AND ABOVE  
4
Impinger I -–Adv Digital – Electric Service Manual - International  
SCHEMATIC DIAGRAM  
MODEL 1454, 1455  
SERIAL NUMBER N28654 AND ABOVE  
TROUBLESHOOTING GUIDE  
Impinger I -–Adv Digital – Electric Service Manual - International  
5
IMPINGER ADVANTAGE ELECTRIC OVENS  
SERIAL NUMBER N28654 AND ABOVE  
(OVENS WITH PUSH BUTTON CONTROLS)  
SYMPTOM  
POSSIBLE CAUSE  
EVALUATION  
Oven fan will not run  
Incoming power supply  
Check circuit breaker, reset if required. Check power  
plug to be sure it is firmly in receptacle. Measure  
incoming power, call power co. if required.  
Check, replace if necessary.  
Fuse, 10 Amp  
Fuse holder  
Check, replace if necessary.  
Thermostat, control  
box hi-limit  
Terminals are normally closed, open at 130°F (55°C). If  
open, reset and test for proper operation. If thermostat  
will not hold, and control box temperature is not  
exceeding 130°F (55°C), replace thermostat.  
Check for line voltage supplied to switch. If no voltage is  
present, trace wiring back to fuse holder. Check  
continuity between switch terminals. Replace switch as  
needed.  
Switch, oven power  
Motor, main fan  
Check for line voltage supplied to motor. If no voltage is  
present, trace wiring back to oven power switch. Check  
motor for opens, shorts or grounds.  
WITH POWER OFF: Turn fan blade to check for locked  
rotor.  
No control box cooling Incoming power supply  
Check circuit breaker, reset if required. Check power  
plug to be sure it is firmly in receptacle. Measure  
incoming power, call power co. if required.  
Check, replace if necessary.  
Fuse, 10 Amp  
Fuse holder  
Check, replace if necessary.  
Switch, oven power  
Check for line voltage supplied to switch. If no voltage  
is present, trace wiring back to fuse holder. Check  
continuity between switch terminals. Replace switch as  
needed.  
Cooling fan  
Check for supply voltage to the cooling fan. If no  
voltage is present, trace wiring back to the fuse holder.  
If voltage is present and motor does not run, check  
motor for opens shorts or grounds.  
WITH POWER OFF: Check for locked rotor.  
Check circuit breaker, reset if required. Check power  
plug to be sure it is firmly in receptacle. Measure  
incoming power, call power co. if required.  
Check cooling fan thermostat (thermostat closes at  
120°F and opens at 100°F). With cooling fan thermostat  
pre-heated, check for continuity  
No automatic control  
box cooling  
Incoming power supply  
Cooling fan thermostat  
Control box cooling fan Cooling fan thermostat  
continues to run  
See “Cooling fan thermostat” (NOTE: Thermostat will  
remain closed if control box temperature remains above  
120°F.  
Oven will not heat  
Main fan  
Air pressure switch  
If not operating, refer to “Oven fan will not run”  
Check air switch terminals for supply voltage to  
terminals NO and COM. If voltage is present on one side  
only, check for air tube blockage or misalignment. If  
these are okay, adjust air pressure switch or replace  
switch as needed.  
Oven cavity hi-limit  
thermostat  
Terminals are normally closed, opens at 660°F (350°C).  
If open, reset and test oven for proper operation. If  
thermostat will not hold for maximum temperature, and  
oven is not exceeding control setting, check for proper  
location of the capillary bulb in its spring holder. If above  
checks are okay, replace hi-limit thermostat.  
Check for supply voltage to primary of control  
transformer. If no voltage is present, trace wiring back to  
oven power switch. If voltage is present, check for  
Impinger I -–Adv Digital – Electric Service Manual - International  
Control transformer  
6
24VAC at transformer secondary. If there is primary  
voltage, but no secondary voltage, replace control  
transformer.  
Oven control  
Check for 24VAC supply to oven control. If no voltage is  
present, trace wiring back to control transformer. Check  
for supply voltage to oven control. If no voltage is  
present, trace wiring back to hi-limit thermostat. If  
voltage is present, check for a read-out on the display. If  
there is no read-out on the display, replace oven control.  
If there is a read-out on the display, set the oven control  
to maximum temperature (see installation operations  
manual for temperature adjustment). With the oven  
control at maximum temperature, check for supply  
voltage to the heat contactor. If there is voltage at the  
heat contactor, proceed to “Heat contactor “. If there is  
no voltage at the heat contactor, trace wiring back to the  
oven control. If there is no voltage output at the oven  
control, check the read-out on the oven control. If the  
oven control reads “PROBE FAIL” this indicates that the  
thermocouple has failed or become disconnected from  
the oven control  
Contactor, hi-limit (Model  
1421-000-E only)  
Check for supply voltage to contactor coil. If no voltage  
is present, trace wiring back to oven cavity hi-limit  
thermostat. If supply voltage is present at the coil, check  
to see that contacts are closed. If there is voltage to the  
coil and the contacts are not closed, replace contactor.  
Check to see that the thermocouple is securely  
connected to the oven control. If the thermocouple is  
connected to the oven control, and the display indicates  
“PROBE FAIL”, disconnect the thermocouple from the  
oven control and measure the resistance of the  
thermocouple. The thermocouple should read approx.  
11Ω. If these readings are not achieved, replace the  
thermocouple. If these readings are correct, proceed.  
If the thermocouple checks good, but the oven control  
display indicates that there is a thermocouple failure,  
replace the oven control. If the oven control indicates a  
temperature reading, but the oven will not heat, proceed.  
WITH POWER ON AND THERMOCOUPLE  
Thermocouple  
Oven control  
Thermocouple  
ATTACHED TO THE OVEN CONTROL: Measure the  
DC millivolt output of the thermocouple. Refer to the  
thermocouple chart (located in the “Removal” section of  
the manual) for proper millivolt readings. If these  
readings are not achieved, replace thermocouple.  
If the thermocouple checks good, but there is no supply  
voltage output to the temperature regulation valve,  
replace the oven control. If there is supply voltage output  
to the heat contactor, proceed.  
Oven control  
Heat contactor  
Check for supply voltage to the heat contactor. If voltage  
is present, listen for contacts to open and close. Also  
check for opens or shorts in the operating coil. Replace  
heat contactor as needed.  
Intermittent heating  
Thermal/overload of main fan The main fan motor is equipped with internal thermal  
motor  
protection and will cease to operate if overheating  
occurs. As the motor overheats and cool, this will cause  
the heating system to cycle on and off intermittently.  
Improper ventilation or lack of preventive maintenance  
may cause this problem. Also most of the problems  
listed under “Oven will not heat” can cause intermittent  
failure.  
Conveyor will not run  
Incoming power supply  
Check circuit breaker, reset if required. Check power  
Impinger I -–Adv Digital – Electric Service Manual - International  
7
plug to be sure it is firmly in receptacle. Measure  
incoming power, call power co. if required.  
Check, replace if necessary.  
Fuse, 10 Amp  
Fuse holder  
Check, replace if necessary.  
Switch, oven power  
Check for line voltage supplied to switch. If no voltage  
is present, trace wiring back to fuse holder. Check  
continuity between switch terminals. Replace switch as  
needed.  
Control transformer  
Conveyor motor  
Check for supply voltage to primary of control  
transformer. If no voltage is present, trace wiring back to  
oven power switch. If voltage is present, check for  
24VAC at transformer secondary. If there is primary  
voltage, but no secondary voltage, replace control  
transformer.  
Check for supply voltage to the conveyor motor at  
terminal #8 to neutral. If no voltage is present, trace  
wiring back to oven power switch. If voltage is present,  
but the motor will not run, check the motor windings for  
opens or shorts. If any of the above checks fail, replace  
conveyor motor.  
Capacitor, conveyor motor  
Check for shorts or grounds. Replace capacitor as  
needed.  
WARNING: Capacitor has a stored charge, discharge  
before testing.  
Switch, conveyor reversing  
Oven control  
Check continuity between switch terminals. Replace  
switch as needed.  
If there is voltage supplied to the motor, and the motor  
capacitor and reversing switch check good, replace the  
oven control.  
Conveyor motor runs,  
but there is no speed  
display  
NOTE: Display will indicate  
“BELT JAM”  
Oven control  
Conveyor motor  
Oven control  
Check for output voltage from oven control to hall effect  
sensor (sensor is located in the conveyor motor).  
Measure voltage at the motor connector, red wire and  
yellow wire. Voltage should be approx. 10VDC. If no  
voltage is present, trace wiring back to oven control. If  
there is no voltage output at the oven control, replace  
oven control.  
If there is voltage supplied to the hall effect sensor,  
check for a frequency output from the hall effect sensor.  
Measure frequency across the yellow and white wires in  
the motor connector. Frequency reading should be  
approx. 25-100 Hz. If these readings are not achieved,  
replace conveyor motor. If the readings are achieved,  
proceed.  
If the hall effect sensor readings are correct, but there is  
no speed indicated on the display, replace the oven  
control.  
REMOVAL, INSTALLATION & ADJUSTMENTS  
IMPINGER ADVANTAGE SERIES  
CAUTION!  
BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER  
OVEN BE SURE TO DISCONNECT ELECTRICAL POWER AND GAS SUPPLY  
8
Impinger I -–Adv Digital – Electric Service Manual - International  
MOTOR, MAIN FAN - REPLACEMENT  
1.Shut off power at main breaker.  
2.Remove louvered motor cover from back of oven.  
3.Remove wireway by taking out the (5) five hex screws.  
4.Disconnect wiring from motor.  
5.Remove the twelve (12) hex head bolts from the oven back and slide back straight out of the oven.  
6.Remove two (2) bolts from fan hub and remove fan from motor shaft.  
NOTE: Measure distance from fan blade to rear wall assembly before removal to aid in reassembly.  
7.Remove the eight (8) hex head bolts from the motor mount and slide the motor assembly out of the oven back.  
8.Remove motor by taking off motor clamp and removing the four (4) mounting nuts and washers.  
9.Reassemble in reverse order. When motor mount assembly is set on the oven back, align motor shaft in the center  
of the hole. Set fan assembly on the motor shaft.  
NOTE: A. Torque specs on bolts (150 in/lb. torque)  
B. It is recommended that an anti-seize compound be brushed on to the bolts around  
the back and motor mount bracket before assembly.  
FAN, MAIN - REPLACEMENT  
Shut off power at main breaker.  
Remove back assembly. (See MOTOR, MAIN FAN))  
Reinstall and locate fan so that the bottom of the fan spider is 1 1/2" from the top of the oven back cone. (See Drawing)  
FAN SPIDER  
NOTE: MEASUREMENT MUST BE  
MADE FROM CONE TO FAN SPIDER  
FAN HUB  
CONE  
1 1/2 INCH  
CAPACITOR, MOTOR - REPLACEMENT  
1.Shut off power at main breaker.  
2.Remove motor cover from back of oven.  
3.Discharge capacitor.  
4.Remove and replace.  
COOLING FAN, CONTROL BOX - REPLACEMENT  
1.Shut off power at main breaker.  
2.Remove control panel top and front cover.  
3.Remove four (4) screws from the fan frame.  
4.Disconnect cord and plug and remove fan.  
5.Reassemble in reverse order.  
THERMOSTAT, COOLING FAN - REPLACEMENT  
1.Shut off power at main breaker.  
2.Remove control panel top and front cover.  
3.Remove lead wires and mark for reassembly.  
4.Remove two (2) screws and remove thermostat.  
5.Reassemble in reverse order.  
Impinger I -–Adv Digital – Electric Service Manual - International  
9
THERMOSTAT, OVEN CAVITY HI-LIMIT – REPLACEMENT  
1. Shut off power at main breaker.  
2. Remove control box cover and front panel. Remove conveyor assembly and fingers from oven to aid in removal of  
thermostat from oven.  
3. Disconnect wires from thermostat and mark for reassembly.  
4. Remove thermostat from oven.  
5. Reassemble in reverse order and check system operation.  
AIR PRESSURE SWITCH – REPLACEMENT  
1.Shut off power at main breaker.  
2.Remove control panel top and front cover.  
3.Disconnect wires from air pressure switch and mark for reassembly.  
4.Remove air switch tube from air pressure switch.  
5.NOTE: There are two types of air pressure switches used. Remove air pressure switch from its mount.  
6.Reassemble in reverse order and check system operation.  
7.To adjust air pressure switch, remove cover from switch to expose adjusting screw. To increase sensitivity, turn  
screw counter-clockwise. To decrease sensitivity, turn screw clockwise.  
THERMOCOUPLE (TYPE K) - REPLACEMENT  
1.Shut off power at main breaker.  
2.Remove control panel top and front cover.  
3.Slide thermocouple out of oven chamber.  
NOTE: Remove conveyor and bottom fingers to aid in removal and installation of thermocouple.  
4.Remove two (2) wires from temperature control. Make note of wire numbers or color and  
location for reinstallation.  
5.Reassemble in reverse order making sure the metal end on the thermocouple is in the wire form in the oven  
chamber.  
THERMOCOUPLE MEASURMENT  
TEMPERATURE  
200°  
D.C. MILLVOLTS (APPROX.)  
2.8  
4.0  
5.1  
6.0  
7.1  
8.2  
9.3  
10.4  
11.5  
250°  
300°  
350°  
400°  
450°  
500°  
550°  
600°  
10  
Impinger I -–Adv Digital – Electric Service Manual - International  
CONTROL TRANSFORMER - REPLACEMENT  
1.Shut power off at main breaker.  
2.Remove control panel top and front cover.  
3.Remove two (2) wires on primary side, note color and location.  
4.Remove two (2) wires on secondary side, note color and location.  
5.Remove two (2) screws from transformer base and replace assembly.  
6.Reinstall in reverse order and check system operation.  
CONVEYOR DRIVE MOTOR - REPLACEMENT  
1.Shut power off at main breaker.  
2.Remove control panel top and front cover.  
3.Loosen set screw on conveyor drive sprocket and slide sprocket off shaft.  
4.Disconnect motor plug.  
5.Remove four (4) screws from motor frame, on control box side, and remove motor assembly.  
6.Reassemble in reverse order making sure to align chain sprockets and adjust motor for proper chain tension  
(1/2" SAG).  
CAPACITOR, CONVEYOR MOTOR – REPLACEMENT  
1.Shut off power at main breaker.  
2.Remove control box cover and front panel.  
3.Discharge capacitor before removing wires. Mark wires for reassembly.  
4.Remove mounting screw and remove capacitor.  
5.eassemble in reverse order and check system operation.  
REVERSING SWITCH – REPLACEMENT  
1. Shut off power at main breaker.  
2. Remove control box cover and front panel.  
3. Disconnect wires from reversing switch and mark for reassembly.  
4. Remove mounting nut and remove reversing switch.  
5. Reassemble in reverse order and check system operation.  
REVERSING CONVEYOR DIRECTION  
All ovens leaving our plant are wired to operate conveyors from left to right. To reverse conveyor  
direction, use the following procedure.  
1.Shut off power at oven switch.  
2.Set conveyor reversing switch in the other position.  
3.Turn oven “on” and check for proper operation.  
ON-OFF SWITCH - REPLACEMENT  
1. Shut off power at main breaker.  
2. Remove control box cover.  
3. Remove access cover.  
4. Depress spring clips on side of switch and push out.  
5. Remove wires from back of switch, note wire number and location.  
6. Reassemble in reverse order and check system operation.  
NOTE: Make sure switch housing is fully seated in control box housing.  
OVEN CONTROL – REPLACEMENT  
A.  
B.  
C.  
D.  
E.  
Shut off power at main breaker.  
Remove control box cover and front panel.  
Remove all wiring connections and mark for reassembly.  
Remove oven control by pulling control from the mounting pins. Remove control from oven.  
Before installing new oven control, set voltage jumper (located at the bottom center of the  
oven control) to the proper voltage (120V/240V) position. Install the four pushbutton extensions  
Impinger I -–Adv Digital – Electric Service Manual - International  
11  
(included with the oven control) by pushing the extensions onto the four set buttons on control.  
Reassemble in reverse order and check system operation.  
F.  
G.  
Set the oven control for the proper operating mode. The 1400 series ovens use a single temperature control  
system. The oven control must be set to the proper operating mode. Set the control as follows: With the oven  
power switch “off”, depress the “time” and “up” buttons and turn the oven “on”. Control will indicate  
“Imp I or Imp II” Release the buttons. Press the “up” or “down” button until “Imp I” and “temp to store” appears  
on the display. Press the “temp” button. The control is now set for Impinger I conveyor and single burner  
operation.  
FUSE HOLDER – REPLACEMENT  
1.  
2.  
3.  
4.  
5.  
Shut off power at main breaker.  
Remove control box cover.  
Remove all wiring from fuse holder and mark for reassembly.  
Remove mounting nut for fuse holder and remove fuse holder.  
Reassemble in reverse order and check system operation.  
BEARING, CONVEYOR – REPLACEMENT  
1. Remove conveyor from oven and place on flat work surface.  
2. Remove connecting links from conveyor belt. See Installation and operations manual.  
3. Remove conveyor belt from conveyor. Remove drive sprocket from drive shaft if required.  
4. Move shaft toward end of conveyor, and shaft with bearings will now slip out of holding bracket.  
5. Replace bearing and reassemble in reverse order.  
HEAT CONTACTOR – REPLACEMENT  
1. Shut off power at main breaker.  
2. Remove control box cover and front panel.  
3. Remove all wiring from contactor and mark for reassembly.  
4. Remove mounting screws and remove contactor.  
5. Reassemble in reverse order and check system operation. NOTE: be sure that contactor is not mounted upside  
down, as this will cause a constant “on” condition.  
HI-LIMIT CONTACTOR – REPLACEMENT  
See “HEAT CONTACTOR – REPLACEMENT”  
EMI FILTER – REPLACEMENT  
1. Shut off power at main breaker.  
2. Remove control box cover and front panel.  
3. Remove all wiring from filter and mark for reassembly.  
4. Remove mounting screws and remove filter.  
5. Reassemble in reverse order and check system operation.  
HEATING ELEMENT – REPLACEMENT  
1. Shut off power at main breaker.  
2. Remove back cover.  
3. Disconnect wiring from heating element and mark wires for reassembly.  
4. Disconnect motor wiring and mark for reassembly.  
5. Remove oven back assembly from oven.  
6. Remove fan shroud.  
7. Remove heating element from oven back.  
8. Reassemble in reverse order and check system operation. NOTE: Be sure heating element connections are tight.  
12  
Impinger I -–Adv Digital – Electric Service Manual - International  
THERMOSTAT, CONTROL BOX HI-LIMIT – REPLACEMENT  
1. Shut off power at main breaker.  
2. Remove control box cover and front panel.  
3. Remove wiring from thermostat and mark for reassembly.  
4. Remove mounting screws and remove thermostat.  
5. Reassemble in reverse order and check system operation. NOTE: Be sure to press reset button on new  
thermostat to set for operation.  
Impinger I -–Adv Digital – Electric Service Manual - International  
13  
GENERAL VIEW  
ADVANTAGE SERIES  
LETTER  
PART NUMBER  
DESCRIPTION  
A
B
C
369003  
369110  
369337  
369929  
369828  
369209  
369310  
369308  
369334  
369309  
350638  
369311  
369336  
369906  
370110  
369157  
1534  
Door hinge  
Access window assembly  
Retainer (old style)  
Retainer (new style)  
Handle spacer  
D
E
F
G
H
J
K
L
M
N
O
P
Q
R
S
T
Latch & strike  
Screw, 6-32 x 3/16”  
Bottom, access window  
Access door glass  
Top, access window  
Handle  
Handle spacer (2 req.)  
Door latch  
Screw, 8-32 x 5/8”  
Door assembly (solid)  
Door assembly (with window)  
Finger support assembly  
Support bracket pin  
Strike assembly  
369057  
369643  
1009  
Oven top  
U
V
W
X
Y
369062  
369140  
369903  
369141  
369139  
369058  
369211  
369203  
369749  
369204  
369373  
369748  
369328  
369052  
369030  
369904  
369053  
Top, control box  
Compression spring  
Washer, flat  
Conveyor hold down bracket  
Shoulder screw  
Baffle, inlet and outlet  
Thumb screw (not shown)  
Stud, wing head  
Chain cover kit (includes AA, CC)  
Split ring retainer  
Receptacle, snap –in  
Bracket, chain cover  
Leg, stand  
Z
*
AA  
BB  
CC  
DD  
EE  
FF  
GG  
HH  
JJ  
KK  
LL  
Adjustable leg  
Caster, 6”  
Insulation holder assembly  
Finger housing  
Columnating plates –  
see installation operations manual  
Finger cover  
Crumb pan, internal  
Window frame, bottom  
Glass, access window  
Window frame, top  
MM  
NN  
OO  
PP  
369055  
369218  
369926  
369925  
369927  
QQ  
14  
Impinger I -–Adv Digital – Electric Service Manual - International  
Impinger I -–Adv Digital – Electric Service Manual - International  
15  
CONTROL BOX  
1421-000-E, 1454,1455  
LETTER  
PART #  
369066  
370373  
369507  
369025  
369119  
369134  
370163  
370387  
370485  
369838  
357107  
369014  
369378  
369331  
370359  
369368  
370388  
370360  
4000054  
369125  
369427  
370362  
370363  
370354  
369432  
370355  
7006831  
DESCRIPTION  
A
B
C
D
E
F
G
H
I
Sprocket, 10 tooth  
Conveyor motor  
Thermostat, cooling fan  
Air pressure switch  
Terminal block  
Fuse, 50A  
Terminal block, 5 Pole  
Filter, EMI  
Contactor, mercury  
Thermostat, control box hi-limit  
Fuse holder  
Fuse, 10A  
Cooling fan  
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
Finger guard  
Reversing switch  
Thermostat, oven cavity hi-limit  
Cover, access  
Capacitor, Conveyor motor  
Ground lug  
Terminal block, 2-pole  
Transformer, control  
Thermocouple, type “K”  
Front cover assembly  
Facia, label  
Switch, on/off  
Oven control  
Top, control panel  
AA  
16  
Impinger I -–Adv Digital – Electric Service Manual - International  
Impinger I -–Adv Digital – Electric Service Manual - International  
17  
OVEN BACK  
ADVANTAGE SERIES  
GAS AND ELECTRIC  
LETTER  
A
PART NUMBER  
DESCRIPTION  
369808  
370140  
369214  
369033  
369215  
369192  
369306  
369646  
369647  
369213  
369547  
369287  
369315  
369122  
Cover, motor (gas ovens)  
Cover, motor (electric ovens)  
Motor, main fan (50 Hz.)  
Motor clamp  
Motor support assembly  
Capacitor, 7.5 MFD  
Oven back assembly, gas oven  
Stand-off  
Inlet panel  
Main fan  
Bracket, thermostat  
Heating element, 208V  
Heating element, 220V  
Heating element, 240V  
B
C
D
E
F
G
H
J
K
M
18  
Impinger I -–Adv Digital – Electric Service Manual - International  
Impinger I -–Adv Digital – Electric Service Manual - International  
19  
CONVEYOR  
1450 SERIES  
LETTER  
A
PART NUMBER  
369830  
DESCRIPTION  
Complete conveyor assembly  
Conveyor belt, 30” Wide  
Conveyor belt, 1 ft. section, 30” Wide  
Conveyor Belt, 32” Wide (units mfg after 10/2003)  
Conveyor Belt, 1 ft. section, 32” Wide  
(units mfg after 10/2003)  
Retaining ring  
Conveyor bearing block  
Roll, conveyor, notched  
Conveyor idler shaft  
369816  
370092  
369163  
369362  
B
C
D
E
F
369825  
369813  
369314  
369812  
369160  
369814  
369005  
369811  
369161  
369806  
370050  
369162  
Conveyor pan stop  
Connecting link (30 inch wide belt)  
Connecting link (32 inch wide belt)  
Conveyor drive shaft  
Roller chain sprocket  
Crumb pan  
G
H
J
K
L
Conveyor frame  
Drive chain  
M
20  
Impinger I -–Adv Digital – Electric Service Manual - International  
Impinger I -–Adv Digital – Electric Service Manual - International  
21  
This page intentionally left blank.  
22  
Impinger I -–Adv Digital – Electric Service Manual - International  
This page intentionally left blank.  
Impinger I -–Adv Digital – Electric Service Manual - International  
23  
Lincoln Foodservice Products, LLC  
1111 North Hadley Road  
Fort Wayne, Indiana 46804  
United States of America  
Telephone: (260) 459-8200  
U.S. Facsimile: (888) 790-8193  
Int’l Facsimile: (260) 436-0735  
Technical Service Hotline: (800) 678-9511  

IBM 6348 User Manual
Krell Industries RS 232 User Manual
LG Electronics L1753TR User Manual
LG Electronics LG Life Good CRT Television 29FX6ALX ZG User Manual
Panasonic CT 36SL13 User Manual
Panasonic TC 1401ZR User Manual
Panasonic TX21FJ50A User Manual
Panasonic WV BM503 User Manual
Philips 107E61 User Manual
Philips MCL1801 User Manual