KitchenAid KGCC566R User Manual 1

®
Gas Built-in Cooktop  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
Metal Cooktops  
KGCC506R  
KGCC566R  
KGCC706R  
KGCC766R  
KGCV566R  
B
Gas Supply: This cooktop is factory set for use  
with Natural gas. Cooktop can be converted to LP  
gas. Provide a gas supply line of ³⁄₄" (1.9 cm) rigid  
pipe to the cooktop location. A smaller size pipe on  
longer runs may result in insufficient gas supply.  
Pipe-joint compounds that resist the action of LP  
gas must be used. Do not use TEFLON® tape. With  
LP gas, piping or tubing size can be ¹⁄₂" minimum.  
Usually, LP gas suppliers determine the size and  
materials used in the system.  
A
C
A. 21¹⁄₄" (53.4 cm)  
B. 31⁷⁄₁₆" (79.8 cm) on 30" (76.2 cm) models,  
37⁹⁄₁₆" (95.4 cm) on 36" (91.4 cm) models  
Electrical: A 120 volt, 60 Hz., AC only, 15-amp  
fused, electrical circuit is required. A time-delay  
fuse or circuit breaker is also recommended. It is  
recommended that a separate circuit serving only  
this cooktop be provided.  
C. 2⁷⁄₈" (7.3 cm)  
Straight-edge glass cooktops  
B
A
C
A. 20⁵⁄₁₆" (51.5 cm)  
B. 30³⁄₁₆" (76.8 cm) on 30" (76.2 cm) models,  
36⁷⁄₁₆" (92.5 cm) on 36" (91.4 cm) models  
CABINET OPENING DIMENSIONS  
C. 2⁷⁄₈" (7.3 cm)  
A
Curved-edge glass cooktops  
D
B
B
C
A
C
F
G
K
E
M
A. 21¹⁄₈" (53.7 cm)  
B. 30⁵⁄₁₆" (77.0 cm) on 30" (76.2 cm) models,  
36⁵⁄₁₆" (92.3 cm) on 36" (91.4 cm) models  
C. 2⁷⁄₈" (7.3 cm)  
H
L
I
J
F. 19" (48.3 cm)  
G. 18" (45.7 cm) minimum clearance from upper cabinet to  
A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models  
countertop within minimum horizontal clearances to cooktop  
B. Combustible area above countertop (shown by dashed box  
H. Grounded outlet - Locate within 24" (61 cm) of right rear  
corner of cutout  
I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models  
J. 8³⁄₈" (21.3 cm) minimum distance to nearest left and right side  
combustible surface  
above)  
C. 30" (76.2 cm) minimum clearance between top of cooktop  
platform and bottom of unprotected wood or metal cabinet  
(24" [61 cm] minimum clearance if bottom of wood or metal  
cabinet is protected by not less than ¹⁄₄" [0.6 cm] flame  
retardant millboard covered with not less than No. 28  
MSG sheet steel, 0.015" [0.04 cm] stainless steel, or  
0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)  
K. 2⁷⁄₈" (7.3 cm) minimum distance to rear combustible surface  
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below  
underside of countertop. Cabinet floor: anywhere within  
6" (15.2 cm) of rear wall is recommended  
D. 13" (33 cm) maximum upper cabinet depth  
E. 2¹⁄₈" (5.4 cm)  
M. 24" (61 cm) minimum countertop depth is required  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8286304  
11-30-05  

KitchenAid KECC568RPB01 User Manual
KitchenAid KECG260 User Manual
Maytag W10251095A User Manual
Moffat Blue Seal Evolution Series E514C CB User Manual
NEC PowerMate 40 GB User Manual
Panasonic TC 2001ZR User Manual
Philips 21PT6334 User Manual
Philips 109E51 User Manual
Philips DECT5153S User Manual
Philips DVDR3390 User Manual