Gas Built-in Cooktop
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
Metal Cooktops
KGCC506R
KGCC566R
KGCC706R
KGCC766R
KGCV566R
B
Gas Supply: This cooktop is factory set for use
with Natural gas. Cooktop can be converted to LP
gas. Provide a gas supply line of ³⁄₄" (1.9 cm) rigid
pipe to the cooktop location. A smaller size pipe on
longer runs may result in insufficient gas supply.
Pipe-joint compounds that resist the action of LP
gas must be used. Do not use TEFLON® tape. With
LP gas, piping or tubing size can be ¹⁄₂" minimum.
Usually, LP gas suppliers determine the size and
materials used in the system.
A
C
A. 21¹⁄₄" (53.4 cm)
B. 31⁷⁄₁₆" (79.8 cm) on 30" (76.2 cm) models,
37⁹⁄₁₆" (95.4 cm) on 36" (91.4 cm) models
Electrical: A 120 volt, 60 Hz., AC only, 15-amp
fused, electrical circuit is required. A time-delay
fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only
this cooktop be provided.
C. 2⁷⁄₈" (7.3 cm)
Straight-edge glass cooktops
B
A
C
A. 20⁵⁄₁₆" (51.5 cm)
B. 30³⁄₁₆" (76.8 cm) on 30" (76.2 cm) models,
36⁷⁄₁₆" (92.5 cm) on 36" (91.4 cm) models
CABINET OPENING DIMENSIONS
C. 2⁷⁄₈" (7.3 cm)
A
Curved-edge glass cooktops
D
B
B
C
A
C
F
G
K
E
M
A. 21¹⁄₈" (53.7 cm)
B. 30⁵⁄₁₆" (77.0 cm) on 30" (76.2 cm) models,
36⁵⁄₁₆" (92.3 cm) on 36" (91.4 cm) models
C. 2⁷⁄₈" (7.3 cm)
H
L
I
J
F. 19" (48.3 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to
A. 30" (76.2 cm) on 30" models; 36" (91.4 cm) on 36" models
countertop within minimum horizontal clearances to cooktop
B. Combustible area above countertop (shown by dashed box
H. Grounded outlet - Locate within 24" (61 cm) of right rear
corner of cutout
I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models
J. 8³⁄₈" (21.3 cm) minimum distance to nearest left and right side
combustible surface
above)
C. 30" (76.2 cm) minimum clearance between top of cooktop
platform and bottom of unprotected wood or metal cabinet
(24" [61 cm] minimum clearance if bottom of wood or metal
cabinet is protected by not less than ¹⁄₄" [0.6 cm] flame
retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015" [0.04 cm] stainless steel, or
0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
K. 2⁷⁄₈" (7.3 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below
underside of countertop. Cabinet floor: anywhere within
6" (15.2 cm) of rear wall is recommended
D. 13" (33 cm) maximum upper cabinet depth
E. 2¹⁄₈" (5.4 cm)
M. 24" (61 cm) minimum countertop depth is required
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.