KitchenAid KECD806R User Manual

®
Electric Built-in Ceramic Downdraft Cooktop  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
KECD806R  
KECD866R  
30-3/8" (77.1 cm) - 30" (76.2 cm) models  
36-3/8" (92.3 cm) - 36" (91.4 cm) models  
width  
21-5/16"  
(54.1 cm)  
depth  
Electrical: A four-wire or three-wire, single-  
phase, 240-volt, 60-Hz, AC-only electrical supply is  
required on a separate 30-ampere circuit, fused on  
both sides of the line. A time-delay fuse or circuit  
breaker is recommended. Connected directly to the  
fused disconnect (or circuit breaker box) through  
flexible, armored or non-metallic sheathed, copper  
cable (with ground wire). Flexible armored cable  
should connect cooktop directly to the junction  
box. A U.L.-listed 1/2" (12.7 mm) conduit  
2-15/16"  
(74.6 mm)  
burner box  
depth  
15-5/8" (39.6 cm)  
blower housing  
depth  
connector must be provided at the junction box.  
The recommended minimum copper wire size is  
10-gauge. However, wire sizes and connections  
must conform to the requirements of the National  
Electrical Code and all local codes and ordinances.  
Venting system: Use metal vent only.  
Exception: Under a concrete slab, PVC may be  
used. Rigid metal vent is recommended. Do not  
use plastic or metal foil vent.  
3-ft. (91.4 cm) long  
power supply cable  
factory installed.  
CABINET OPENING DIMENSIONS  
Minimum base cabinet  
dimensions —  
30" (76.2 cm) base cabinet width  
24" (61 cm) base cabinet depth  
25" (63.5 cm) countertop depth  
30" (76.2 cm) min - 30" (76.2 cm) model  
36" (91.4 cm) min - 36" (91.4 cm) model  
when higher than 18" (45.7 cm)  
This downdraft cooktop is rated at 60 feet  
(18.3 m) of straight vent or the equivalent.  
If vent length is 10 feet (3 m) or less, 6" (15.2 cm)  
diameter round vent may be used. If vent length is  
more than 10 feet (3 m), use 6" (15.2 cm)  
diameter round or 3-1/4" x 10" (8.3 x 25.4 cm)  
rectangular vent.  
Countertop opening dimensions that  
are shown must be used. Given  
dimensions are minimum clearances  
and provide required 0" (0 cm)  
clearance.  
New installations — Follow  
minimum dimensions given.  
Replacement installation — Be sure  
that front edge of cooktop is at least  
1-1/2" (38.1 mm) back from front  
edge of countertop.  
If cabinet has drawers, drawers will  
need to be removed and drawer  
fronts installed on front of cabinet.  
See Note ** for  
minimum clearances  
Venting system must terminate to the outside.  
21" (53.3 cm)  
opening depth  
Minimum distance  
Do Not seal  
cooktop to countertop.  
to nearest combustible  
vertical surface  
Cooktop location should be away from strong draft  
areas, such as windows, doors and strong heating  
vents or fans.  
All openings in the wall or floor where cooktop is  
to be installed must be sealed.  
extending 18" (45.7 cm)  
above cooktop  
1" (25.4 mm)  
29-1/2" (74.9 cm) - 30" (76.2 cm) model  
35-1/2" (90.2 cm) - 36" (91.4 cm) model  
cutout width  
Side clearance — 6" (15.2 cm)  
minimum clearance between side of  
cooktop and side wall is  
recommended for maximum  
ventilation performance.  
Note: 24" (61 cm) minimum when bottom of wood or metal  
cabinet is protected by not less than 1/4" (6.4 mm) flame  
retardant millboard covered with not less than No. 28 MSG sheet  
steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum  
or 0.020" (0.5 mm) copper.  
**  
Rear clearance — 3/4" (19.1 mm)  
clearance between rear edge of  
cooktop and rear wall is  
recommended.  
30" (76.2 cm) minimum clearance between the top of the cooking  
platform and bottom of unprotected wood or sheet metal.  
Motor/blower clearance —  
2" (51 mm) minimum clearance  
between motor and cabinet is  
required for proper cooling. 6"  
(15.2 cm) clearance is  
29-1/2" (74.9 cm) - 30" (76.2 cm) model  
35-1/2" (90.2 cm) - 36" (91.4 cm) model  
cutout width  
9-3/4" (24.8 cm)  
Exhaust Duct  
Cutout Locations  
hole in rear or  
17"  
(43.2 cm)  
side of cabinet  
21" (53.3 cm)  
cutout depth  
recommended for servicing access.  
countertop  
9-5/8" (24.4 cm) -  
30" (76.2 cm) cooktop  
5" (12.7 cm)  
13-5/16" (33.8 cm) -  
36" (91.4 cm) cooktop  
2" (5.1 cm)  
minimum space  
to front edge of  
countertop  
18"  
(45.7 cm)  
Countertop must be  
Select required duct cutout  
(see Page 4 for exhaust duct  
cutout location).  
supported within  
3" (7.6 cm) of cutout.  
floor  
8" (20.3 cm)  
11" (27.9 cm)  
Install rear wall junction box in shaded area.  
Darker area is preferred.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8286553  
08-11-05  

Innovative Ideas Limited LCD Monitor Arm 9103 User Manual
JVC AV 21QS5SP User Manual
JVC I'Art LCT1855 001B A User Manual
Lava Computer Computer Hardware LavaPort Quad User Manual
Lindy 20288 User Manual
Moffat Blue Seal G518B LS User Manual
Moffat RN8406E LS User Manual
Philips 29PT4622 User Manual
Philips 150S5FS User Manual
Philips Magnavox PR1909B User Manual