Intel AXXRAKSAS2 User Manual

Intel® RAID Activation Key AXXRAKSAS2  
Install Guide  
Order Number: D92007-001  
Important Safety Instructions  
Read all caution and safety statements in this document before performing any of the instructions.  
See Intel Server Boards and Server Chassis Safety Information at  
Wichtige Sicherheitshinweise  
Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine  
der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-  
Serverplatinen und -Servergehäusen unter  
重要安全指导  
在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。  
Server Boards and Server Chassis Safety Information(《Intel  
服务器主板与服务器机箱安全信息》)。  
Important Safety InstructionsConsignes de sécurité  
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document  
avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety  
010770.htm.  
Instrucciones de seguridad importantes  
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar  
cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en  
WARNINGS  
Server power on/off: The push-button on/off power switch on the front  
panel of the server does not turn off the AC power. To remove AC power  
from the server, you must unplug the AC power cord from either the power  
supply or wall outlet.  
Hazardous conditions: power supply, cables: Hazardous voltage, current,  
and energy levels are present inside the power supply enclosure and may be  
present on power and communication cables. Turn off the server and  
disconnect all cables attached to the server before opening it. Otherwise,  
personal injury or equipment damage can result  
Contents  
Important Safety Instructions ............................................................................iii  
Preface ................................................................................................................ iv  
1 About Intel® RAID Activation Keys............................................................... 1  
Intel® Integrated Server RAID Requirements.................................................... 2  
Installing the Intel® RAID Activation Key AXXRAKSAS2 ................................ 2  
Prepare the Server..................................................................................................................2  
Install the Intel® RAID Activation Key......................................................................................3  
Install the RAID DIMM or Mini-DIMM......................................................................................4  
Finish the Installation ..............................................................................................................5  
Enable and Configure Hardware RAID.............................................................. 5  
Preface  
About this Manual  
Thank you for purchasing and using the Intel® RAID Activation Key AXXRAKSAS2.  
This manual is for system technicians who are responsible this RAID Activation Key. It provides a  
brief overview of the features of the AXXRAKSAS2, and instructions on how to install the  
component. For the latest version of this manual, see  
Product Contents  
Your kit came with these components  
ƒ
ƒ
One Intel® RAID Activation Key AXXRAKSAS2  
These instructions  
iv  
1 About Intel® RAID Activation Keys  
Intel® RAID Activation Keys enable RAID features on Intel® server boards. Several models of  
Intel® RAID Activation Keys are available for different RAID products and to serve different  
purposes.  
This guide is specific to the Intel® RAID Activation Key with the order code, AXXRAKSAS2.  
This key enables hardware RAID across all modes (0, 1, 5, 6, 10, 50, and 60) on these Intel® server  
boards and systems that include an Intel® Integrated Server RAID Module using the LSI* 1078  
ROC controller:  
ƒ
ƒ
ƒ
Intel® Server System S7000FC4UR with SAS riser  
Intel® Server System SR1550ALSAS with 1078-based active midplane  
Intel® Server System SR2500ALLX with 1078-based active midplane  
This guide does not apply to these Intel® RAID Activation Keys:  
ƒ
AXXRAK18E enables integrated hardware RAID 0,1,5,10 and 50 on these systems:  
-
-
-
-
-
-
Intel® Server System SR4850HW4/M with product code SHW4URM3SA  
Intel® Server System SR6850HW4/M with product code SHW6URM3SA  
Intel® Server System S5000PSLROMB using LSI* 1068  
Intel® Server System SC5400RA using LSI 1068  
Intel® Server System SR1550ALSAS using LSI 1068-based active midplane.  
Intel® Server System SR2500ALLX using LSI 1068-based active midplane.  
ƒ
ƒ
AXXRAKSW5 enables software RAID 5 on Intel® Server Boards that include Intel®  
Embedded Server RAID Technology II. This key enables software RAID 5 with the ESB2  
SATA controller and / or the 1064E SAS / SATA controller. Except for the Intel Server  
Platforms SR1550AL and SR2500AS (product codes SR1550ALSAS and SR2500ALLX),  
SAS server boards can include two AXXRAKSW5 sockets.  
AXXRAKU42E is used to enable RAID on the SCSI ROMB models of these Intel® Server  
Boards and Platforms that include an on-board SCSI controller:  
-
-
-
Intel® Server Board SE7520AF2  
Intel® Server System SR4850HW4/M with product code SHW4UR/M  
Intel® Server System SR6850HW4/M with product code SHW6UR/M  
Intel® RAID Activation Key AXXRAKSAS2 Install Guide  
1
Intel® Integrated Server RAID Requirements  
Intel® Integrated Server RAID requires a DIMM in addition to the standard server board DIMMs or  
FBDIMMs. The Intel® Server System S7000FC4UR SAS riser includes a full-size DIMM socket  
for this DIMM, and the SR1550ALSAS and SR2500LX provide a mini-DIMM socket. Only use  
memory DIMMs listed under the RAID module section of the Tested Memory List, available under  
the listing for your system at http://support.intel.com/support/motherboards/server.  
A backup battery, the Intel® RAID Smart Battery Backup Unit (AXXRSBBU4), is available to  
prevent data loss in the RAM cache if AC power is lost. The backup battery maintains the data for  
up to 72 hours. The Smart Battery Backup Unit mounts to the RAID controller card.  
Installing the Intel® RAID Activation Key  
Prepare the Server  
1. Observe all safety and ESD precautions at the beginning of this guide and in the documentation  
for your server board and chassis.  
2. If your server system is running, power off all peripheral devices attached to the server, power  
down the server, and disconnect the AC power cord from the server.  
3. Remove the chassis cover. See your server chassis documentation for instructions.  
2
Install the Intel® RAID Activation Key  
1. Remove the RAID Activation Key from its packaging.  
2. See your server board or system documentation to locate the ROMB connection in your server.  
It may be on a midplane board or on the SAS riser board in a specially keyed PCI Express*  
slot.  
3. With the Intel name on the RAID Activation Key facing up, insert the RAID Activation Key  
into the socket.  
4. Make sure the Key is fully seated. The metal clips on the socket sit on the top edge of the Key.  
Figure 1. Installing the RAID Activation Key on Intel® Server System S7000FC4UR SAS Riser  
AF000479  
Figure 2. Installing RAID Activation Key on Midplane Board  
Intel® RAID Activation Key AXXRAKSAS2 Install Guide  
3
Install the RAID DIMM or Mini-DIMM  
1. Open the clips on each side of the DIMM socket.  
2. Holding the DIMM by the edges, remove it from its anti-static package.  
3. Align the notch on the DIMM with the key in the DIMM socket.  
4. Push the DIMM firmly into the socket. The clips will latch. Make sure the clips are firmly  
latched.  
Figure 3. Installing DIMM on Intel® Server System S7000FC4UR SAS Riser  
AF000481  
Figure 4. Installing Mini-DIMM on Midplane Board  
4
Finish the Installation  
1. (Optional) Follow the instructions included with the Intel RAID Smart Battery (AXXRSBBU4)  
to install this accessory.  
2. Reinstall any components inside of the server chassis that you needed to remove. See your  
server board or chassis documentation for instructions.  
3. Install the server chassis cover and connect the AC power supply.  
Enable and Configure Hardware RAID  
After you boot your system, update the firmware for the RAID function of the LSI* 1078  
controller. The update package is available at http://support.intel.com. Follow the instructions in the  
firmware package to update the firmware and enable hardware RAID.  
For RAID configuration instructions, see the RAID Software User’s Guide.  
Intel® RAID Activation Key AXXRAKSAS2 Install Guide  
5

JVC DVD & HDD VIDEORECORDER DR MH50S User Manual
Konftel Conference Phone 50 User Manual
LG Electronics LG Life Good Computer Monitor L226WTX User Manual
LG Electronics LG Life Good Computer Monitor W2353V User Manual
Mitsubishi Electronics CK 35308 User Manual
Philips 29PT5026C User Manual
Philips 107E60 User Manual
Philips 170B7CS User Manual
Philips 170S8FB User Manual
Philips 13512832 User Manual