QuickSpecs
Overview
HP bc1000 blade PC
HP bc1000 blade PC
At a Glance
1.0-GHz Transmeta Efficeon TM8000
40-GB Ultra ATA/100 5400 rpm hard drive
512-MB DDR SDRAM PC2700 (333-MHz) expandable to 1024 MB (2 SODIMM slots)
(NOTE: 32 MB of system RAM is reserved for processor usage.)
Two Broadcom 5705F 10/100 Integrated Network Controllers. NIC 1 is compliant with PXE (Pre-boot execution Environment)
Connector for graphics diagnostics card
Blade PCs protected by HP Services, including a limited three-year parts warranty with optional service uplifts available
DA - 11903
North America — Version 5 — May 20, 2005
Page 1
QuickSpecs
Standard Features
HP bc1000 blade PC
HP bc1000 blade PC
Processor
One Transmeta Efficeon TM8000 1.0-GHz processor, integrated North Bridge with 400-MHz Hyper
Transport South Bridge interface
Cache Memory
Chipset
1024K L2
ALi M1563M South Bridge
NOTE: For more information regarding Acer Labs Inc, please see the following URL:
Memory
Standard
Maximum
512-MB DDR SDRAM PC2700 (333-MHz) (1x512 MB SODIMM)
(NOTE: 32 MB of system RAM is reserved for processor usage.)
1024 MB (2 SODIMM slots total)
Network Controller
Internal Storage
Two 5705F 10/100 Integrated Network Controllers. NIC 1is compliant with PXE
One 40-GB Ultra ATA/100 5400 rpm hard drive
Industry Standard
Compliance
ACPI 1.0b; ANSI C63.4 - 1992; C.I.S.P.R. Pub 22; CFR 47, Part 15; EN 55022; EN 55024;
EN 60950: 2000; ICES-003; IEC 61000-4, Section 2-6, 8, 11; IEC 730-1; IEC 801, Part 2;
IPC-A-610; PC2700; PCI 2.3; PXE 2.1; SPD 1.2B; UL 94; UL 796; USB 1.1
Manageability
HP Systems Insight Manager
ROM Based Setup Utility (RBSU)
Automatic System Recovery (ASR)
System Software Manager (SSM)
DOS-based replicated setup utility (REPSET)
Unit ID LED
High Availability
Robust boot block recovery ROM
F5 auto roll over to new blade
Dual network communication paths
Security
Administrator's password
OS Support
Microsoft® Windows® XP Pro with Service Pack 1a
DA - 11903
North America — Version 5 — May 20, 2005
Page 3
QuickSpecs
Standard Features
HP bc1000 blade PC
HP e-Class Blade PC Enclosure (sold separately)
Rack Capability
Mounts in HP 10000 and 9000 series, HP System-E, as well as third-party, and Telco racks. Rack
mounting hardware for HP and third-party racks ships standard with each blade enclosure. Telco rack-
mounting hardware is a separately available option kit.
Rack Airflow
Requirements
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted blade PCs. The HP 10000 Series Racks provide enhanced airflow for
maximum cooling, allowing these racks to be fully loaded with blade PCs using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U rack includes closing front and rear doors, you must allow
5,350 square cm (830 square inches) of hole evenly distributed from top to bottom to permit
adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be
a minimum of 7 cm (2.75 inches).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling
that can lead to thermal damage.
NOTE: Please consult the Setup & Installation Guide for the blade PC for additional details.
Enclosure includes
3U high rack-mountable chassis with 20 blade PC bays
Rack mounting hardware for HP, Compaq-branded and third-party racks
Rear bay for Interconnect Switch for network cable management
Two (2) Diagnostic Adapters (see features following) for connecting keyboard, video, mouse and other
devices locally to individual blade PCs
ProLiant Essentials Foundation Pack licenses for 20 Blade PCs (see features following), includes the HP
Systems Insight Manager and ProLiant Essentials Rapid Deployment Pack CD
Four hot-plug fans
Dual hot-plug power supplies (600 watts each), power cords
Blade PC blanks (to fill 19 of the 20 blade PC bays)
Null-modem cable for serial connection to the Integrated Administrator serial "Console" connector
HP Documentation CD
Diagnostic Adapter
Interfaces
NOTE: Two Diagnostic Adapters are included with every enclosure.
Blade PC LEDs (6)
PS/2 Mouse
PS/2 Keyboard
VGA monitor (functional only when graphics diagnostics card installed)
Serial RS-232 port
USB 1.1 ports (2)
DA - 11903
North America — Version 5 — May 20, 2005
Page 4
QuickSpecs
Standard Features
HP bc1000 blade PC
ProLiant Essentials
Foundation Pack Software Manager
HP Systems Insight
Systems Insight Manager helps maximize system uptime and performance
and reduces the cost of maintaining the IT infrastructure by providing
proactive notification of problems before those problems result in costly
downtime and reduced productivity. Insight Manager is easy to set up and
provides rapid access to inventory information.
ProLiant Essentials Rapid An automated solution for deployment and provisioning, enabling
Deployment Pack
companies to quickly and easily adapt to changing business demands.
NOTE: For more information regarding ProLiant Essentials Software, please
Interconnect Switch
Full featured web-based interface, menu-driven console interface, SNMP-
Management System and based scripting utility and example scripts, SNMP and RMON MIBs, and
Utilities TFTP utilities for management of interconnect switch.
C-GbE Interconnect Switch Features (sold separately)
Provides up to a 40-to-1 reduction in network cables for each blade enclosure using a pair of non-blocking layer 2 switch
modules
Four RJ-45 10/100/1000T Gigabit Ethernet uplinks
Forty 10/100T Ethernet ports dedicated to blade-to-interconnect switch network communications
Communicate with all 40 blade PC network controllers through any one uplink connector and the management connector
Includes Integrated Administrator module (see features following)
Spanning tree protocol for loop-free path redundancy
Browser, scriptable CLI, and console-based interfaces for local and remote interconnect switch management
Manage entire interconnect switch through the Integrated Administrator connectors or any uplink connector
Telnet, RMON and SNMP support; SNMP-based scripting utility with example scripts
IGMP (internet group management protocol) multicasting and quality of service (QoS) packet prioritization
TFTP support for rapid deployment of multiple interconnect switches and to provide backup and restore capabilities
Industry-standard design compatible with industry-standard network components from leading network manufacturers
Fully pre-configured for rapid deployment and immediate operation in HP e-Class Blade PC Enclosure
For more information on the C-GbE Interconnect Switch, please visit the Web site at:
DA - 11903
North America — Version 5 — May 20, 2005
Page 5
QuickSpecs
Standard Features
HP bc1000 blade PC
HP Integrated Administrator Features
Out-of-band local console and remote network access to the blade enclosure and all 20 blade PCs via (one) RJ-45
10/100BaseT Fast Ethernet and (one) RS-232 management connectors
Provides local and remote access to the C-GbE Interconnect Switch command console
Remotely power on/off/reboot blade PCs and enclosures
Remotely toggle on/off unit identification (UID) LEDs of blade PCs and enclosures
Monitors and controls the enclosure fans, temperature sensors, power supplies, interconnect switch and blade PC status
Connect to each blade PC's serial text console for enabling full control over blade PC's Power-On Self Test (POST) and boot
process, including the ROM-Based Setup Utility (RBSU).
User administration for up to 25 users. Blade PC bay privileges can be set on a per-user basis
Virtual NMI button generates non-maskable interrupt for crash debug and analysis
More than 100 scriptable commands enable automated management
Selective enabling of all protocols, such as Telnet
Logging of operating system console, blade PC and enclosure hardware events, user actions and invalid login attempts
Administrator notification that a blade is warm
Enclosure controller blade shutdown (graceful Windows shutdown) if blade overheats
Emergency blade shutdown in the event of a critical temperature fault
Enclosure Link (2) connectors reserved for future use.
CAUTION: The enclosure link (RJ-45) connectors on the interconnect tray are not to be used. Connecting an external device to
these enclosure link (RJ-45) connecters may damage your external device.
For more information on the Integrated Administrator, please visit the Web site at:
Service and Support
HP Services provides a wide range of service offerings, including a three-year, limited parts warranty on
the HP bc1000 blade PC.
CAUTION: Do not ship the blade PCs and enclosure while inside the rack without first installing the e-
Class Enclosure Shipping Bracket (part number PH555A). Failure to use the shipping bracket may cause
damage to the blade PC and/or enclosure, thereby voiding the warranty.
The HP e-Class Blade PC Enclosure has a three-year, limited warranty on parts, labor and on-site
support.
Warranties are fully supported by a network of resellers and service providers in over 160 countries. HP
warranty assistance is available 7x24, toll free in the United States and Canada. Other additional
support services may be covered under warranty or available for an additional fee.
A full range of HP Care Pack packaged hardware and software services:
Add labor or on-site service for the blade PC
Installation and start up
Extended coverage hours and enhanced response times
System management and performance services
Availability and recovery services
NOTE: Certain restrictions and exclusions apply. Consult the Customer Support Center at 1-800-567-
1616 for details.
DA - 11903
North America — Version 5 — May 20, 2005
Page 6
QuickSpecs
Models
HP bc1000 blade PC
bc1000 blade PC
DS658A (1 pack)
Processor
1.0-GHz Transmeta Efficeon TM8000
1024K L2
Cache Memory
Memory
512-MB DDR SDRAM PC2700 (333-MHz)
Two Broadcom 5705F 10/100 Integrated NICs
40-GB Ultra ATA/100 5400 rpm
Network Controller
Hard Drive
Form Factor
Plugs vertically into HP e-Class Blade PC Enclosure
bc1000 blade PC
DS659A (10 pack)
Processor
1.0-GHz Transmeta Efficeon TM8000
1024K L2
Cache Memory
Memory
512-MB DDR SDRAM PC2700 (333-MHz)
Two Broadcom 5705F 10/100 Integrated NICs
40-GB Ultra ATA/100 5400 rpm
Network Controller
Hard Drive
Form Factor
Plugs vertically into HP e-Class Blade PC Enclosure
DA - 11903
North America — Version 5 — May 20, 2005
Page 7
QuickSpecs
Options
HP bc1000 blade PC
Enclosure and Switch
HP e-Class Blade PC Enclosure (includes 20 licenses for ProLiant Essentials Rapid
DW366A
Deployment Pack at 50% of the standard per-node license list price)
Enclosure Shipping Bracket Kit
NOTE: When shipping an enclosure in a rack, shipping brackets must be installed to
the rack.
C-GbE Interconnect Switch (includes Integrated Administrator module)
DW367A
PA715A
Memory
512-MB DDR SDRAM PC2700 (333-MHz) Option Kit (1 x 512 MB)
Miscellaneous
PS/2 Mouse
DD440B
DT527A
PS/2 Keyboard
TFT5600 Rackmount Keyboard and Monitor
TFT721OR 17-inch Rackmount Monitor
Integrated Keyboard and Drawer
External USB MultiBay Caddy
Third-party Rail Kit for HP Input Devices
Telco Rail Kit for HP Input Devices
MultiBay 24X CD-ROM
221546-001
348373-B21
257054-001
DC373A#ABA
287139-B21
287138-B21
217396-930
DV300C
Graphics Diagnostics Card (5 pack)
UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and
specifications for UPS and PDU units:
Uninterruptible Power
Systems – Rack
HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage
204404-001
192186-001
192186-002
347207-001
Rack-Mountable UPS R6000 (6000VA, 6000 Watt) High Voltage
NOTE: The UPS R6000 has a hardwired input.
UPS R12000 XR N+ x (200-240V) (hardwired)
207552-B22
NOTE: The UPS R12000 XR has a hardwired input and output.
DA - 11903
North America — Version 5 — May 20, 2005
Page 8
QuickSpecs
Options
HP bc1000 blade PC
UPS Options
SNMP Serial Port Card
NOTE: Supports tower and rack UPS XR models ranging from 1000 – 3000VA.
192189-B21
Six Port Card
192185-B21
388643-B21
NOTE: Supports tower and rack UPS XR models ranging from 1000 – 3000VA.
High to Low Voltage Transformer (250VA)
NOTE: Supports R6000 UPS series only. 2.5 amps @ 125 Volts max output across
two NEMA 5-15.
Extended Runtime Module, R1500 XR
NOTE: 2U each, two ERM maximum.
218971-B21
192188-B21
326564-B21
347224-B21
217800-B21
325361-001
325361-B21
347225-B21
123508-B21
123509-B21
Extended Runtime Module, R3000 XR
NOTE: 2U each, one ERM maximum.
Extended Runtime Module, R5500 XR
NOTE: 3U each, two ERM maximum.
Extended Runtime Module, R6000
NOTE: 3U each, two ERM maximum.
Extended Runtime Module, R12000 XR, 4U
NOTE: 4U each, two ERM maximum.
R12000 XR BackPlate Receptacle Kit, (2) L6-30R
NOTE: The R12000 XR BackPlate Kit has a hardwired input.
R12000 XR BackPlate Receptacle Kit, (2) IEC-309R
NOTE: The R12000 XR BackPlate Kit has a hardwired input.
SNMP-EN Adapter
NOTE: Supports R6000 UPS series only.
Multi-Server UPS Card
NOTE: Supports R6000 UPS series only.
Scalable UPS Card
NOTE: Supports R6000 UPS series only.
Rack-Mountable PDUs – HP Power Distribution Unit-16A (200 to 240V)
1U/0U (Up to 12 outlets) NOTE: The 16A PDU also connects to the high volt models of the UPS R3000 XR
207590-B21
207590-B23
NOTE: 0U mounting
(need cable PN 340653-001) and the UPS R6000 models. Cable PN 340653-001
brackets shipped with the required if connecting to UPS R3000 XR (192186-002-High Volt model only).
unit (separate option kit
for 1U mounting).
HP Power Distribution Unit-40A (200 to 240V)
NOTE: Please see the following Power Distribution Unit (Zero-U/1U PDU)
QuickSpecs for additional options, including cables:
DA - 11903
North America — Version 5 — May 20, 2005
Page 9
QuickSpecs
Options
HP bc1000 blade PC
Modular PDUs 1U/0U
(Up to 32 outlets)
Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)
NOTE: This model has a detachable input power cord and is adaptable to country
252663-B24
specific requirements. The 16A PDU also connects to the high volt models of the UPS
R3000 XR and R6000 models. Cable P/N 340653-001 required if connecting to UPS
R3000 XR (192186-002-High Volt model only).
Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)
Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)
252663-D72
252663-D71
252663-B21
Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U
Modular PDUs) QuickSpecs for additional options including shorter jumper cables
and country specific power cords:
PDU Options
Third Party PDU Mounting Kit
310777-B21
NOTE: This kit allows you to mount the Modular PDUs in racks other than the
9000/10000 Series racks (any racks using the standard 19" rail). For more details
please refer the Modular PDU QuickSpecs.
Enterprise Configurator
HP Rack 10000 Series
(Graphite Metallic)
S10614 (14U) Rack Cabinet – Shock Pallet
HP Rack 10647 (47U) – Pallet
292302-B22
245160-B21
245160-B23
245161-B21
245161-B22
245161-B23
245162-B21
245162-B22
245162-B23
245163-B21
245163-B22
245163-B23
257415-B21
257415-B22
HP Rack 10647 (47U) – Crated
HP Rack 10642 (42U) – Pallet
HP Rack 10642 (42U) – Shock Pallet
HP Rack 10642 (42U) – Crated
HP Rack 10636 (36U) – Pallet
HP Rack 10636 (36U) – Shock Pallet
HP Rack 10636 (36U) – Crated
HP Rack 10622 (22U) – Pallet
HP Rack 10622 (22U) – Shock Pallet
HP Rack 10622 (22U) – Crated
HP Rack 10842 (42U) – 800 mm wide – Pallet
HP Rack 10842 (42U) – Crated
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems,
VARs and Channels)
-B23 (crated) used for air shipments of empty racks
NOTE: Not all HP equipment is qualified to be shipped in the Rack 10000 series.
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as
height, width, depth, weight, and color:
For additional information regarding Rack Cabinets, please see the following URL:
DA - 11903
North America — Version 5 — May 20, 2005
Page 10
QuickSpecs
Options
HP bc1000 blade PC
Rack Options for HP Rack Rack Blanking Panels – Graphite (Multi)
253214-B26
253214-B21
253214-B22
253214-B23
253214-B24
253214-B25
10000 Series
NOTE: Contains one each of 1U, 2U, 4U and 8U.
Rack Blanking Panels – Graphite (1U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (1U).
Rack Blanking Panels – Graphite (2U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (2U).
Rack Blanking Panels – Graphite (3U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (3U).
Rack Blanking Panels – Graphite (4U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (4U).
Rack Blanking Panels – Graphite (5U)
NOTE: The Rack Blanking Panels Kit contains 10 each of (5U).
600mm Stabilizer Kit – Graphite
246107-B21
248929-B21
246099-B21
257413-B21
Baying Kit for Rack 10000 series (Carbon)
42U Side Panel – Graphite Metallic
110V Fan Kit (Graphite)
NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 5-15P.
220V Fan Kit (Graphite)
257414-B21
NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 6-15P.
36U Side Panel – Graphite Metallic
47U Side Panel – Graphite Metallic
9000/10000 Series Offset Baying Kit (42U)
246102-B21
255486-B21
248931-B21
NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U
height together. Kit contents include hardware for connecting racks and a panel to
cover the 100mm gap at the rear of the two racks.
Cable Management
FC Cable Routing Spool – box of 12
Rail-to-Rail FC Cable Routing
293357-B21
293358-B21
293359-B21
292407-B21
168233-B21
Side Rail FC Routing – box of 6
Compaq Networking Cable Management Kit
Cable Management D-Rings Kit
Rack Options for Rack
10000 Series
Monitor Utility Shelf
303606-B21
120672-B21
234672-B21
120675-B21
260457-B21
234672-B21
Ballast Option Kit
100kg Sliding Shelf
Rack Rail Adapter Kit (25" depth)
9000/10000 Grounding Kit
100-kg Shelf Kit
NOTE: This 100Kg Shelf Kit (PN 234672-B21) supports the Rack 10000 and 9000
series only.
DA - 11903
North America — Version 5 — May 20, 2005
Page 11
QuickSpecs
Options
HP bc1000 blade PC
Rack Options for HP,
Third Party and Telco
racks
Telco rack-mounting hardware kit for HP e-Class Blade PC Enclosure
Enclosure Shipping Bracket Kit
NOTE: When shipping an enclosure in a rack shipping brackets must be installed to
the rack.
266076-B21
293119-B21
NOTE: For more information on rack and rack options, please visit the following url:
DA - 11903
North America — Version 5 — May 20, 2005
Page 12
QuickSpecs
Memory
HP bc1000 blade PC
HP bc1000 blade PC
Standard Memory
512-MB 333-MHz DDR SDRAM (1x512 MB SODIMM) installed. (NOTE: 32 MB of system RAM is reserved for processor usage.)
Standard Memory Plus Optional Memory
Up to 1024 MB of DDR SDRAM is available with the installation of optional DDR SDRAM memory expansion kits (sold separately).
Memory
Slot
1
2
Standard
Maximum
512 MB
Empty
512 MB
512 MB
512 MB
1024 MB
DA - 11903
North America — Version 5 — May 20, 2005
Page 13
QuickSpecs
Technical Specifications
HP bc1000 blade PC
HP bc1000 blade PC
Dimensions
Height
4.7 in (11.94 cm)
0.8 in (2.03 cm)
15.5 in (39.37 cm)
2.2 lb (1.0 kg)
Width
Depth
Weight
Maximum
Operating
1
Temperature
50° to 95° F (10° to 35° C)
Non-operating shipping -40° to 140° F (-40° to 60° C)
Non-operating storage
Operating
-4° to 140° F (-20° to 60° C)
10% to 90%
1
Relative humidity
(noncondensing)
Non-operating shipping 10% to 90%
Non-operating storage
Unit identification
10% to 95%
LEDs (Top to bottom)
Off = off
Steady blue = blade identified
Blinking blue = being accessed remotely
Off = off
Health
Green = health good
Amber = degraded or power up prohibited by
the Integrated Administrator
Blinking or steady red = critical
Off = off
NIC 1
NIC 2
Green = linked to network
Blinking green = Activity on network
Off = off
Green = linked to network
Blinking green = activity on network
Off = No drive activity
Drive activity
Power
Blinking green = drive activity
Off = no AC power to blade or enclosure
Amber = Enclosure on and in good health
Green = blade power on
NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage
maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.
40-GB Ultra ATA/100
Hard Drive
Capacity
Interface
40 GB
Ultra ATA 100
Transfer rate synchronous 100 MB/s
(maximum)
Seek time (typical reads, Single track
1.5 ms
12 ms
22 ms
including settling)
Average
Maximum
Rotational speed
5400 rpm
DA - 11903
North America — Version 5 — May 20, 2005
Page 14
QuickSpecs
Technical Specifications
HP bc1000 blade PC
Broadcom 5705F 10/100
Integrated NIC
Network interface
10Base-T/100Base-TX
Compatibility
IEEE 802.3/802.3u compliant
32-bit bus-master PCI
Data transfer method
Features
NIC 1 WOL enabled and PXE compliant
Network transfer rate
10Base-T (half-duplex)
10Base-T (full-duplex)
10 Mb/s
20 Mb/s
100Base-TX (half-duplex) 100 Mb/s
100Base-TX (full-duplex) 200 Mb/s
Mates into enclosure center wall assembly
Connector
Cable support
10Base-T
Categories 3, 5, or 6 UTP; up to 328 ft (100 m)
Category 5 or 6 UTP; up to 328 ft (100 m)
100Base-TX
Enclosure
Dimensions
Height (3U)
Width
5.25 in (13.34 cm)
19 in (48.26 cm)
27 in (68.58 cm)
59 lb (26.76 kg)
103 lb (46.7 kg)
Depth
Weight (with interconnect No blade PCs
tray)
20 blade PCs
Rated input (autosensing) Voltage
Minimum: 90 VAC
Maximum: 264 VAC
Nominal: 100 to 120 VAC or 200 to 240 VAC
Frequency
Current
47 to 63 Hz
11.7 A at 90 VAC
8.5 A at 120 VAC
4.3 A at 240 VAC
Power
1000 W
BTUs
Per hour
3416
1
Temperature
Operating
50° to 95° F (10° to 35° C)
-40° to 140° F (-40° to 60° C)
10% to 90%
Shipping, 72 hours
Operating
Relative humidity
(noncondensing)
Non-operating
10% to 95%
Management
Enclosure self recovery
Health logs
Redundant power supply utility
Automatic System Recovery (ASR)
High availability
Redundant hot-plug power supplies
Redundant hot-plug fans
NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage
maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.
DA - 11903
North America — Version 5 — May 20, 2005
Page 15
QuickSpecs
Technical Specifications
HP bc1000 blade PC
Enclosure Hot-Plug Power
Supply
Dimensions
Height
3.579 in (9.14 cm)
10.24 in (28.45 cm)
4.47 in (11.43 cm)
Depth
Width
Weight
6.5 lb (2.95 kg)
Voltage (autosensing)
Frequency
Rated input
100 to 127 VAC (200 to 240 VAC)
47 to 63 Hz
Current
8.5 A at 120 VAC (4.3 A at 240 VAC)
1000 W
Power
Maximum peak power
Voltage/current
1167 W
Rated output
5.01 V - 0.5 A ~ 34 A
3.33 V - 0.5 A ~ 36 A
12.1 V - 0.5 A ~ 38 A
5 Vaux - 0.2 A ~ 8 A
600 W
Power RMS
Maximum peak power
Operating
700 W for 2 minutes
5° to 55° F (10° to 35° C)
1
Temperature
Non-operating, shipping -40° to 85° F (-40° to 60° C)
1
Relative humidity
(noncondensing)
Operating
10% to 90%
Non-operating
Input to output
Input to ground
10% to 95%
Dieletric voltage
withstand
2000 VAC minimum
1500 VAC minimum
NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage
maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.
C-GbE Interconnect
Switch
General
Two 24-port Managed Layer 2 Ethernet switches for network cable
reduction; fully pre-configured for immediate operation
Performance
4.0 Gbps Switching bandwidth
12 million pps aggregate throughput (64-byte packets)
Full-wire speed for all connections
Store and forward
Forwarding mode
MAC addresses
16,382; MAC address based filtering and MAC address packet priority
configuring
Memory
64 MB Main
12 MB Flash
32 MB Packet Buffer
DA - 11903
North America — Version 5 — May 20, 2005
Page 16
QuickSpecs
Technical Specifications
HP bc1000 blade PC
Ports
Four RJ-45 10/100/1000 T/TX/T Gigabit Ethernet uplink ports for customer
use
Forty 10/100 T/TX fast Ethernet downlink ports dedicated to blade PC to
interconnect switch network connections
Two 10/100 T/TX Fast Ethernet ports dedicated to inter-switch module
communications
One RS-232 DB-9 port (console connector for Integrated Administrator)
One 10/100 T/TX Fast Ethernet port (Network management connector for
Integrated Administrator)
Auto-negotiation and auto-sensing with full-duplex
Web-based interface with graphical user interface
Console menu driven Interface via local RS-232 and Telnet
Scriptable command line interface (CLI)
Management
SNMP v1 (RFC 1157) with scripting tool and example scripts
RMON v1 (RFC 1757) groups 1, 2, 3, and 9
Telnet (RFC 854)
MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface MIB (RFC 2233),
801.1Q MIB (RFC 2684), RMON1 MIB (RFC 1757) groups 1, 2, 3, and 9,
Ethernet MIB (RFC1643) and HP-specific switch MIBs
XML human read/write configuration file
TFTP client (RFC 783) for backup and remote download of configuration
and history log files
IGMP (Internet Group Management Protocol) multicasting
Uplink port speed and link activity LEDs
Simple network time protocol (SNTP)
Broadcast, multicast, and DA-unknown packet storm control
BootP and DHCP client support
Port mirroring
HP Interconnect Switch Management System and Utilities
High availability
Security
Dual network communication paths using redundant, non-blocking layer 2
switch modules with redundant inter-module communication links
Two redundant uplink ports per each interconnect switch module
Spanning tree protocol for loop-free path redundancy
Multilevel user names and passwords with configurable time out period
setting, IP address restriction
IEEE standards
compliance
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Ethernet
IEEE 802.3ab 1000Base-T Ethernet
IEEE 802.1D Spanning Tree Protocol
IEEE 802.1p Quality of Service (QoS) Packet Prioritization
IEEE 802.3x Flow Control
Form factor
Removable interconnect tray that plugs into the rear of the server blade
enclosure
DA - 11903
North America — Version 5 — May 20, 2005
Page 17
QuickSpecs
Technical Specifications
HP bc1000 blade PC
Network transfer rate
10Base-T (half-duplex)
10Base-T (full-duplex)
10 Mb/s
20 Mb/s
100Base-TX (half-duplex) 100 Mb/s
100Base-TX (full-duplex) 200 Mb/s
1000Base-T (full-duplex, 2000 Mb/s
uplink ports only)
Cable support
10Base-T
Categories 3, 5, or 6 UTP; up to 328 ft (100 m)
Category 5 or 6 UTP; up to 328 ft (100 m)
100Base-TX
1000Base-T (uplink ports Category 5 or 6 UTP; up to 328 ft (100 m)
only)
© Copyright 2005 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
DA - 11903
North America — Version 5 — May 20, 2005
Page 18
|