HP Hewlett Packard HP blade PC bc1000 User Manual

QuickSpecs  
Overview  
HP bc1000 blade PC  
HP bc1000 blade PC  
At a Glance  
1.0-GHz Transmeta Efficeon TM8000  
40-GB Ultra ATA/100 5400 rpm hard drive  
512-MB DDR SDRAM PC2700 (333-MHz) expandable to 1024 MB (2 SODIMM slots)  
(NOTE: 32 MB of system RAM is reserved for processor usage.)  
Two Broadcom 5705F 10/100 Integrated Network Controllers. NIC 1 is compliant with PXE (Pre-boot execution Environment)  
Connector for graphics diagnostics card  
Blade PCs protected by HP Services, including a limited three-year parts warranty with optional service uplifts available  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 1  
QuickSpecs  
Standard Features  
HP bc1000 blade PC  
HP bc1000 blade PC  
Processor  
One Transmeta Efficeon TM8000 1.0-GHz processor, integrated North Bridge with 400-MHz Hyper  
Transport South Bridge interface  
Cache Memory  
Chipset  
1024K L2  
ALi M1563M South Bridge  
NOTE: For more information regarding Acer Labs Inc, please see the following URL:  
Memory  
Standard  
Maximum  
512-MB DDR SDRAM PC2700 (333-MHz) (1x512 MB SODIMM)  
(NOTE: 32 MB of system RAM is reserved for processor usage.)  
1024 MB (2 SODIMM slots total)  
Network Controller  
Internal Storage  
Two 5705F 10/100 Integrated Network Controllers. NIC 1is compliant with PXE  
One 40-GB Ultra ATA/100 5400 rpm hard drive  
Industry Standard  
Compliance  
ACPI 1.0b; ANSI C63.4 - 1992; C.I.S.P.R. Pub 22; CFR 47, Part 15; EN 55022; EN 55024;  
EN 60950: 2000; ICES-003; IEC 61000-4, Section 2-6, 8, 11; IEC 730-1; IEC 801, Part 2;  
IPC-A-610; PC2700; PCI 2.3; PXE 2.1; SPD 1.2B; UL 94; UL 796; USB 1.1  
Manageability  
HP Systems Insight Manager  
ROM Based Setup Utility (RBSU)  
Automatic System Recovery (ASR)  
System Software Manager (SSM)  
DOS-based replicated setup utility (REPSET)  
Unit ID LED  
High Availability  
Robust boot block recovery ROM  
F5 auto roll over to new blade  
Dual network communication paths  
Security  
Administrator's password  
OS Support  
Microsoft® Windows® XP Pro with Service Pack 1a  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 3  
QuickSpecs  
Standard Features  
HP bc1000 blade PC  
HP e-Class Blade PC Enclosure (sold separately)  
Rack Capability  
Mounts in HP 10000 and 9000 series, HP System-E, as well as third-party, and Telco racks. Rack  
mounting hardware for HP and third-party racks ships standard with each blade enclosure. Telco rack-  
mounting hardware is a separately available option kit.  
Rack Airflow  
Requirements  
The increasing power of new high-performance processor technology requires increased cooling  
efficiency for rack-mounted blade PCs. The HP 10000 Series Racks provide enhanced airflow for  
maximum cooling, allowing these racks to be fully loaded with blade PCs using the latest processors.  
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure  
adequate airflow and to prevent damage to the equipment:  
Front and rear doors: If your 42U rack includes closing front and rear doors, you must allow  
5,350 square cm (830 square inches) of hole evenly distributed from top to bottom to permit  
adequate airflow (equivalent to the required 64 percent open area for ventilation).  
Side: The clearance between the installed rack component and the side panels of the rack must be  
a minimum of 7 cm (2.75 inches).  
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This  
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling  
that can lead to thermal damage.  
NOTE: Please consult the Setup & Installation Guide for the blade PC for additional details.  
Enclosure includes  
3U high rack-mountable chassis with 20 blade PC bays  
Rack mounting hardware for HP, Compaq-branded and third-party racks  
Rear bay for Interconnect Switch for network cable management  
Two (2) Diagnostic Adapters (see features following) for connecting keyboard, video, mouse and other  
devices locally to individual blade PCs  
ProLiant Essentials Foundation Pack licenses for 20 Blade PCs (see features following), includes the HP  
Systems Insight Manager and ProLiant Essentials Rapid Deployment Pack CD  
Four hot-plug fans  
Dual hot-plug power supplies (600 watts each), power cords  
Blade PC blanks (to fill 19 of the 20 blade PC bays)  
Null-modem cable for serial connection to the Integrated Administrator serial "Console" connector  
HP Documentation CD  
Diagnostic Adapter  
Interfaces  
NOTE: Two Diagnostic Adapters are included with every enclosure.  
Blade PC LEDs (6)  
PS/2 Mouse  
PS/2 Keyboard  
VGA monitor (functional only when graphics diagnostics card installed)  
Serial RS-232 port  
USB 1.1 ports (2)  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 4  
QuickSpecs  
Standard Features  
HP bc1000 blade PC  
ProLiant Essentials  
Foundation Pack Software Manager  
HP Systems Insight  
                                                 
                                                    
                                                      
                                                       
                                                         
                                                         
                                                           
                                                              
                                                                
                                                                 
                                                                   
                                                                    
                                                                     
                                                                       
                                                                         
Systems Insight Manager helps maximize system uptime and performance  
and reduces the cost of maintaining the IT infrastructure by providing  
proactive notification of problems before those problems result in costly  
downtime and reduced productivity. Insight Manager is easy to set up and  
provides rapid access to inventory information.  
ProLiant Essentials Rapid An automated solution for deployment and provisioning, enabling  
Deployment Pack  
companies to quickly and easily adapt to changing business demands.  
NOTE: For more information regarding ProLiant Essentials Software, please  
Interconnect Switch  
Full featured web-based interface, menu-driven console interface, SNMP-  
Management System and based scripting utility and example scripts, SNMP and RMON MIBs, and  
Utilities TFTP utilities for management of interconnect switch.  
C-GbE Interconnect Switch Features (sold separately)  
Provides up to a 40-to-1 reduction in network cables for each blade enclosure using a pair of non-blocking layer 2 switch  
modules  
Four RJ-45 10/100/1000T Gigabit Ethernet uplinks  
Forty 10/100T Ethernet ports dedicated to blade-to-interconnect switch network communications  
Communicate with all 40 blade PC network controllers through any one uplink connector and the management connector  
Includes Integrated Administrator module (see features following)  
Spanning tree protocol for loop-free path redundancy  
Browser, scriptable CLI, and console-based interfaces for local and remote interconnect switch management  
Manage entire interconnect switch through the Integrated Administrator connectors or any uplink connector  
Telnet, RMON and SNMP support; SNMP-based scripting utility with example scripts  
IGMP (internet group management protocol) multicasting and quality of service (QoS) packet prioritization  
TFTP support for rapid deployment of multiple interconnect switches and to provide backup and restore capabilities  
Industry-standard design compatible with industry-standard network components from leading network manufacturers  
Fully pre-configured for rapid deployment and immediate operation in HP e-Class Blade PC Enclosure  
For more information on the C-GbE Interconnect Switch, please visit the Web site at:  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 5  
QuickSpecs  
Standard Features  
HP bc1000 blade PC  
HP Integrated Administrator Features  
Out-of-band local console and remote network access to the blade enclosure and all 20 blade PCs via (one) RJ-45  
10/100BaseT Fast Ethernet and (one) RS-232 management connectors  
Provides local and remote access to the C-GbE Interconnect Switch command console  
Remotely power on/off/reboot blade PCs and enclosures  
Remotely toggle on/off unit identification (UID) LEDs of blade PCs and enclosures  
Monitors and controls the enclosure fans, temperature sensors, power supplies, interconnect switch and blade PC status  
Connect to each blade PC's serial text console for enabling full control over blade PC's Power-On Self Test (POST) and boot  
process, including the ROM-Based Setup Utility (RBSU).  
User administration for up to 25 users. Blade PC bay privileges can be set on a per-user basis  
Virtual NMI button generates non-maskable interrupt for crash debug and analysis  
More than 100 scriptable commands enable automated management  
Selective enabling of all protocols, such as Telnet  
Logging of operating system console, blade PC and enclosure hardware events, user actions and invalid login attempts  
Administrator notification that a blade is warm  
Enclosure controller blade shutdown (graceful Windows shutdown) if blade overheats  
Emergency blade shutdown in the event of a critical temperature fault  
Enclosure Link (2) connectors reserved for future use.  
CAUTION: The enclosure link (RJ-45) connectors on the interconnect tray are not to be used. Connecting an external device to  
these enclosure link (RJ-45) connecters may damage your external device.  
For more information on the Integrated Administrator, please visit the Web site at:  
Service and Support  
HP Services provides a wide range of service offerings, including a three-year, limited parts warranty on  
the HP bc1000 blade PC.  
CAUTION: Do not ship the blade PCs and enclosure while inside the rack without first installing the e-  
Class Enclosure Shipping Bracket (part number PH555A). Failure to use the shipping bracket may cause  
damage to the blade PC and/or enclosure, thereby voiding the warranty.  
The HP e-Class Blade PC Enclosure has a three-year, limited warranty on parts, labor and on-site  
support.  
Warranties are fully supported by a network of resellers and service providers in over 160 countries. HP  
warranty assistance is available 7x24, toll free in the United States and Canada. Other additional  
support services may be covered under warranty or available for an additional fee.  
A full range of HP Care Pack packaged hardware and software services:  
Add labor or on-site service for the blade PC  
Installation and start up  
Extended coverage hours and enhanced response times  
System management and performance services  
Availability and recovery services  
NOTE: Certain restrictions and exclusions apply. Consult the Customer Support Center at 1-800-567-  
1616 for details.  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 6  
QuickSpecs  
Models  
HP bc1000 blade PC  
bc1000 blade PC  
DS658A (1 pack)  
Processor  
                                                 
                                                  
                                                    
                                                     
                                                       
                                                        
                                                          
                                                            
1.0-GHz Transmeta Efficeon TM8000  
1024K L2  
Cache Memory  
Memory  
512-MB DDR SDRAM PC2700 (333-MHz)  
Two Broadcom 5705F 10/100 Integrated NICs  
40-GB Ultra ATA/100 5400 rpm  
Network Controller  
Hard Drive  
Form Factor  
Plugs vertically into HP e-Class Blade PC Enclosure  
bc1000 blade PC  
DS659A (10 pack)  
Processor  
1.0-GHz Transmeta Efficeon TM8000  
1024K L2  
Cache Memory  
Memory  
512-MB DDR SDRAM PC2700 (333-MHz)  
Two Broadcom 5705F 10/100 Integrated NICs  
40-GB Ultra ATA/100 5400 rpm  
Network Controller  
Hard Drive  
Form Factor  
Plugs vertically into HP e-Class Blade PC Enclosure  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 7  
QuickSpecs  
Options  
HP bc1000 blade PC  
Enclosure and Switch  
HP e-Class Blade PC Enclosure (includes 20 licenses for ProLiant Essentials Rapid  
DW366A  
Deployment Pack at 50% of the standard per-node license list price)  
Enclosure Shipping Bracket Kit  
NOTE: When shipping an enclosure in a rack, shipping brackets must be installed to  
the rack.  
C-GbE Interconnect Switch (includes Integrated Administrator module)  
DW367A  
PA715A  
Memory  
512-MB DDR SDRAM PC2700 (333-MHz) Option Kit (1 x 512 MB)  
Miscellaneous  
PS/2 Mouse  
DD440B  
DT527A  
PS/2 Keyboard  
TFT5600 Rackmount Keyboard and Monitor  
TFT721OR 17-inch Rackmount Monitor  
Integrated Keyboard and Drawer  
External USB MultiBay Caddy  
Third-party Rail Kit for HP Input Devices  
Telco Rail Kit for HP Input Devices  
MultiBay 24X CD-ROM  
221546-001  
348373-B21  
257054-001  
DC373A#ABA  
287139-B21  
287138-B21  
217396-930  
DV300C  
Graphics Diagnostics Card (5 pack)  
UPS and PDU Power  
Cord Matrix  
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and  
specifications for UPS and PDU units:  
Uninterruptible Power  
Systems – Rack  
HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage  
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage  
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage  
204404-001  
192186-001  
192186-002  
347207-001  
Rack-Mountable UPS R6000 (6000VA, 6000 Watt) High Voltage  
NOTE: The UPS R6000 has a hardwired input.  
UPS R12000 XR N+ x (200-240V) (hardwired)  
207552-B22  
NOTE: The UPS R12000 XR has a hardwired input and output.  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 8  
QuickSpecs  
Options  
HP bc1000 blade PC  
UPS Options  
SNMP Serial Port Card  
NOTE: Supports tower and rack UPS XR models ranging from 1000 – 3000VA.  
192189-B21  
Six Port Card  
192185-B21  
388643-B21  
NOTE: Supports tower and rack UPS XR models ranging from 1000 – 3000VA.  
High to Low Voltage Transformer (250VA)  
NOTE: Supports R6000 UPS series only. 2.5 amps @ 125 Volts max output across  
two NEMA 5-15.  
Extended Runtime Module, R1500 XR  
NOTE: 2U each, two ERM maximum.  
218971-B21  
192188-B21  
326564-B21  
347224-B21  
217800-B21  
325361-001  
325361-B21  
347225-B21  
123508-B21  
123509-B21  
Extended Runtime Module, R3000 XR  
NOTE: 2U each, one ERM maximum.  
Extended Runtime Module, R5500 XR  
NOTE: 3U each, two ERM maximum.  
Extended Runtime Module, R6000  
NOTE: 3U each, two ERM maximum.  
Extended Runtime Module, R12000 XR, 4U  
NOTE: 4U each, two ERM maximum.  
R12000 XR BackPlate Receptacle Kit, (2) L6-30R  
NOTE: The R12000 XR BackPlate Kit has a hardwired input.  
R12000 XR BackPlate Receptacle Kit, (2) IEC-309R  
NOTE: The R12000 XR BackPlate Kit has a hardwired input.  
SNMP-EN Adapter  
NOTE: Supports R6000 UPS series only.  
Multi-Server UPS Card  
NOTE: Supports R6000 UPS series only.  
Scalable UPS Card  
NOTE: Supports R6000 UPS series only.  
Rack-Mountable PDUs – HP Power Distribution Unit-16A (200 to 240V)  
1U/0U (Up to 12 outlets) NOTE: The 16A PDU also connects to the high volt models of the UPS R3000 XR  
207590-B21  
207590-B23  
NOTE: 0U mounting  
(need cable PN 340653-001) and the UPS R6000 models. Cable PN 340653-001  
brackets shipped with the required if connecting to UPS R3000 XR (192186-002-High Volt model only).  
unit (separate option kit  
for 1U mounting).  
HP Power Distribution Unit-40A (200 to 240V)  
NOTE: Please see the following Power Distribution Unit (Zero-U/1U PDU)  
QuickSpecs for additional options, including cables:  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 9  
QuickSpecs  
Options  
HP bc1000 blade PC  
Modular PDUs 1U/0U  
(Up to 32 outlets)  
Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)  
NOTE: This model has a detachable input power cord and is adaptable to country  
252663-B24  
specific requirements. The 16A PDU also connects to the high volt models of the UPS  
R3000 XR and R6000 models. Cable P/N 340653-001 required if connecting to UPS  
R3000 XR (192186-002-High Volt model only).  
Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)  
Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)  
252663-D72  
252663-D71  
252663-B21  
Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)  
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.  
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U  
Modular PDUs) QuickSpecs for additional options including shorter jumper cables  
and country specific power cords:  
PDU Options  
Third Party PDU Mounting Kit  
310777-B21  
NOTE: This kit allows you to mount the Modular PDUs in racks other than the  
9000/10000 Series racks (any racks using the standard 19" rail). For more details  
please refer the Modular PDU QuickSpecs.  
Enterprise Configurator  
HP Rack 10000 Series  
(Graphite Metallic)  
S10614 (14U) Rack Cabinet – Shock Pallet  
HP Rack 10647 (47U) – Pallet  
292302-B22  
245160-B21  
245160-B23  
245161-B21  
245161-B22  
245161-B23  
245162-B21  
245162-B22  
245162-B23  
245163-B21  
245163-B22  
245163-B23  
257415-B21  
257415-B22  
HP Rack 10647 (47U) – Crated  
HP Rack 10642 (42U) – Pallet  
HP Rack 10642 (42U) – Shock Pallet  
HP Rack 10642 (42U) – Crated  
HP Rack 10636 (36U) – Pallet  
HP Rack 10636 (36U) – Shock Pallet  
HP Rack 10636 (36U) – Crated  
HP Rack 10622 (22U) – Pallet  
HP Rack 10622 (22U) – Shock Pallet  
HP Rack 10622 (22U) – Crated  
HP Rack 10842 (42U) – 800 mm wide – Pallet  
HP Rack 10842 (42U) – Crated  
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck  
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems,  
VARs and Channels)  
-B23 (crated) used for air shipments of empty racks  
NOTE: Not all HP equipment is qualified to be shipped in the Rack 10000 series.  
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as  
height, width, depth, weight, and color:  
For additional information regarding Rack Cabinets, please see the following URL:  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 10  
QuickSpecs  
Options  
HP bc1000 blade PC  
Rack Options for HP Rack Rack Blanking Panels – Graphite (Multi)  
253214-B26  
253214-B21  
253214-B22  
253214-B23  
253214-B24  
253214-B25  
10000 Series  
NOTE: Contains one each of 1U, 2U, 4U and 8U.  
Rack Blanking Panels – Graphite (1U)  
NOTE: The Rack Blanking Panels Kit contains 10 each of (1U).  
Rack Blanking Panels – Graphite (2U)  
NOTE: The Rack Blanking Panels Kit contains 10 each of (2U).  
Rack Blanking Panels – Graphite (3U)  
NOTE: The Rack Blanking Panels Kit contains 10 each of (3U).  
Rack Blanking Panels – Graphite (4U)  
NOTE: The Rack Blanking Panels Kit contains 10 each of (4U).  
Rack Blanking Panels – Graphite (5U)  
NOTE: The Rack Blanking Panels Kit contains 10 each of (5U).  
600mm Stabilizer Kit – Graphite  
246107-B21  
248929-B21  
246099-B21  
257413-B21  
Baying Kit for Rack 10000 series (Carbon)  
42U Side Panel – Graphite Metallic  
110V Fan Kit (Graphite)  
NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 5-15P.  
220V Fan Kit (Graphite)  
257414-B21  
NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 6-15P.  
36U Side Panel – Graphite Metallic  
47U Side Panel – Graphite Metallic  
9000/10000 Series Offset Baying Kit (42U)  
246102-B21  
255486-B21  
248931-B21  
NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U  
height together. Kit contents include hardware for connecting racks and a panel to  
cover the 100mm gap at the rear of the two racks.  
Cable Management  
FC Cable Routing Spool – box of 12  
Rail-to-Rail FC Cable Routing  
293357-B21  
293358-B21  
293359-B21  
292407-B21  
168233-B21  
Side Rail FC Routing – box of 6  
Compaq Networking Cable Management Kit  
Cable Management D-Rings Kit  
Rack Options for Rack  
10000 Series  
Monitor Utility Shelf  
303606-B21  
120672-B21  
234672-B21  
120675-B21  
260457-B21  
234672-B21  
Ballast Option Kit  
100kg Sliding Shelf  
Rack Rail Adapter Kit (25" depth)  
9000/10000 Grounding Kit  
100-kg Shelf Kit  
NOTE: This 100Kg Shelf Kit (PN 234672-B21) supports the Rack 10000 and 9000  
series only.  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 11  
QuickSpecs  
Options  
HP bc1000 blade PC  
Rack Options for HP,  
Third Party and Telco  
racks  
Telco rack-mounting hardware kit for HP e-Class Blade PC Enclosure  
Enclosure Shipping Bracket Kit  
NOTE: When shipping an enclosure in a rack shipping brackets must be installed to  
the rack.  
266076-B21  
293119-B21  
NOTE: For more information on rack and rack options, please visit the following url:  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 12  
QuickSpecs  
Memory  
HP bc1000 blade PC  
HP bc1000 blade PC  
Standard Memory  
512-MB 333-MHz DDR SDRAM (1x512 MB SODIMM) installed. (NOTE: 32 MB of system RAM is reserved for processor usage.)  
Standard Memory Plus Optional Memory  
Up to 1024 MB of DDR SDRAM is available with the installation of optional DDR SDRAM memory expansion kits (sold separately).  
Memory  
Slot  
1
2
Standard  
Maximum  
512 MB  
Empty  
512 MB  
512 MB  
512 MB  
1024 MB  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 13  
QuickSpecs  
Technical Specifications  
HP bc1000 blade PC  
HP bc1000 blade PC  
Dimensions  
Height  
4.7 in (11.94 cm)  
0.8 in (2.03 cm)  
15.5 in (39.37 cm)  
2.2 lb (1.0 kg)  
Width  
Depth  
Weight  
Maximum  
Operating  
1
Temperature  
50° to 95° F (10° to 35° C)  
Non-operating shipping -40° to 140° F (-40° to 60° C)  
Non-operating storage  
Operating  
-4° to 140° F (-20° to 60° C)  
10% to 90%  
1
Relative humidity  
(noncondensing)  
Non-operating shipping 10% to 90%  
Non-operating storage  
Unit identification  
10% to 95%  
LEDs (Top to bottom)  
Off = off  
Steady blue = blade identified  
Blinking blue = being accessed remotely  
Off = off  
Health  
Green = health good  
Amber = degraded or power up prohibited by  
the Integrated Administrator  
Blinking or steady red = critical  
Off = off  
NIC 1  
NIC 2  
Green = linked to network  
Blinking green = Activity on network  
Off = off  
Green = linked to network  
Blinking green = activity on network  
Off = No drive activity  
Drive activity  
Power  
Blinking green = drive activity  
Off = no AC power to blade or enclosure  
Amber = Enclosure on and in good health  
Green = blade power on  
NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage  
maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.  
40-GB Ultra ATA/100  
Hard Drive  
Capacity  
Interface  
40 GB  
Ultra ATA 100  
Transfer rate synchronous 100 MB/s  
(maximum)  
Seek time (typical reads, Single track  
1.5 ms  
12 ms  
22 ms  
including settling)  
Average  
Maximum  
Rotational speed  
5400 rpm  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 14  
QuickSpecs  
Technical Specifications  
HP bc1000 blade PC  
Broadcom 5705F 10/100  
Integrated NIC  
Network interface  
                                                  
                                                    
                                                    
                                                       
                                                         
                                                          
                                                            
                                                             
                                                               
                                                                
                                                                  
                                                                   
                                                                    
                                                                     
                                                                       
10Base-T/100Base-TX  
Compatibility  
IEEE 802.3/802.3u compliant  
32-bit bus-master PCI  
Data transfer method  
Features  
NIC 1 WOL enabled and PXE compliant  
Network transfer rate  
10Base-T (half-duplex)  
10Base-T (full-duplex)  
10 Mb/s  
20 Mb/s  
100Base-TX (half-duplex) 100 Mb/s  
100Base-TX (full-duplex) 200 Mb/s  
Mates into enclosure center wall assembly  
Connector  
Cable support  
10Base-T  
Categories 3, 5, or 6 UTP; up to 328 ft (100 m)  
Category 5 or 6 UTP; up to 328 ft (100 m)  
100Base-TX  
Enclosure  
Dimensions  
Height (3U)  
Width  
5.25 in (13.34 cm)  
19 in (48.26 cm)  
27 in (68.58 cm)  
59 lb (26.76 kg)  
103 lb (46.7 kg)  
Depth  
Weight (with interconnect No blade PCs  
tray)  
20 blade PCs  
Rated input (autosensing) Voltage  
Minimum: 90 VAC  
Maximum: 264 VAC  
Nominal: 100 to 120 VAC or 200 to 240 VAC  
Frequency  
Current  
47 to 63 Hz  
11.7 A at 90 VAC  
8.5 A at 120 VAC  
4.3 A at 240 VAC  
Power  
1000 W  
BTUs  
Per hour  
3416  
1
Temperature  
Operating  
50° to 95° F (10° to 35° C)  
-40° to 140° F (-40° to 60° C)  
10% to 90%  
Shipping, 72 hours  
Operating  
Relative humidity  
(noncondensing)  
Non-operating  
10% to 95%  
Management  
Enclosure self recovery  
Health logs  
Redundant power supply utility  
Automatic System Recovery (ASR)  
High availability  
Redundant hot-plug power supplies  
Redundant hot-plug fans  
NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage  
maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 15  
QuickSpecs  
Technical Specifications  
HP bc1000 blade PC  
Enclosure Hot-Plug Power  
Supply  
Dimensions  
                                                  
                                                  
                                                     
                                                       
                                                         
                                                          
                                                           
                                                             
                                                               
Height  
                                                                                        
                                                                                          
                                                                                           
                                                                                             
                                                                                               
3.579 in (9.14 cm)  
10.24 in (28.45 cm)  
4.47 in (11.43 cm)  
Depth  
Width  
Weight  
6.5 lb (2.95 kg)  
Voltage (autosensing)  
Frequency  
Rated input  
100 to 127 VAC (200 to 240 VAC)  
47 to 63 Hz  
Current  
8.5 A at 120 VAC (4.3 A at 240 VAC)  
1000 W  
Power  
Maximum peak power  
Voltage/current  
1167 W  
Rated output  
5.01 V - 0.5 A ~ 34 A  
3.33 V - 0.5 A ~ 36 A  
12.1 V - 0.5 A ~ 38 A  
5 Vaux - 0.2 A ~ 8 A  
600 W  
Power RMS  
Maximum peak power  
Operating  
700 W for 2 minutes  
5° to 55° F (10° to 35° C)  
1
Temperature  
Non-operating, shipping -40° to 85° F (-40° to 60° C)  
1
Relative humidity  
(noncondensing)  
Operating  
10% to 90%  
Non-operating  
Input to output  
Input to ground  
10% to 95%  
Dieletric voltage  
withstand  
2000 VAC minimum  
1500 VAC minimum  
NOTE 1: Operating temperature has an altitude derating of 34° F (1° C) per 1,000 ft (304.8 m). No direct sunlight. Storage  
maximum humidity of 95% is based on a maximum temperature of 112° F (45° C). Minimum pressure for storage is 70 KPa.  
C-GbE Interconnect  
Switch  
General  
Two 24-port Managed Layer 2 Ethernet switches for network cable  
reduction; fully pre-configured for immediate operation  
Performance  
4.0 Gbps Switching bandwidth  
12 million pps aggregate throughput (64-byte packets)  
Full-wire speed for all connections  
Store and forward  
Forwarding mode  
MAC addresses  
16,382; MAC address based filtering and MAC address packet priority  
configuring  
Memory  
64 MB Main  
12 MB Flash  
32 MB Packet Buffer  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 16  
QuickSpecs  
Technical Specifications  
HP bc1000 blade PC  
Ports  
Four RJ-45 10/100/1000 T/TX/T Gigabit Ethernet uplink ports for customer  
use  
Forty 10/100 T/TX fast Ethernet downlink ports dedicated to blade PC to  
interconnect switch network connections  
Two 10/100 T/TX Fast Ethernet ports dedicated to inter-switch module  
communications  
One RS-232 DB-9 port (console connector for Integrated Administrator)  
One 10/100 T/TX Fast Ethernet port (Network management connector for  
Integrated Administrator)  
Auto-negotiation and auto-sensing with full-duplex  
Web-based interface with graphical user interface  
Console menu driven Interface via local RS-232 and Telnet  
Scriptable command line interface (CLI)  
Management  
SNMP v1 (RFC 1157) with scripting tool and example scripts  
RMON v1 (RFC 1757) groups 1, 2, 3, and 9  
Telnet (RFC 854)  
MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface MIB (RFC 2233),  
801.1Q MIB (RFC 2684), RMON1 MIB (RFC 1757) groups 1, 2, 3, and 9,  
Ethernet MIB (RFC1643) and HP-specific switch MIBs  
XML human read/write configuration file  
TFTP client (RFC 783) for backup and remote download of configuration  
and history log files  
IGMP (Internet Group Management Protocol) multicasting  
Uplink port speed and link activity LEDs  
Simple network time protocol (SNTP)  
Broadcast, multicast, and DA-unknown packet storm control  
BootP and DHCP client support  
Port mirroring  
HP Interconnect Switch Management System and Utilities  
High availability  
Security  
Dual network communication paths using redundant, non-blocking layer 2  
switch modules with redundant inter-module communication links  
Two redundant uplink ports per each interconnect switch module  
Spanning tree protocol for loop-free path redundancy  
Multilevel user names and passwords with configurable time out period  
setting, IP address restriction  
IEEE standards  
compliance  
IEEE 802.3 10Base-T Ethernet  
IEEE 802.3u 100Base-TX Ethernet  
IEEE 802.3ab 1000Base-T Ethernet  
IEEE 802.1D Spanning Tree Protocol  
IEEE 802.1p Quality of Service (QoS) Packet Prioritization  
IEEE 802.3x Flow Control  
Form factor  
Removable interconnect tray that plugs into the rear of the server blade  
enclosure  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 17  
QuickSpecs  
Technical Specifications  
HP bc1000 blade PC  
Network transfer rate  
10Base-T (half-duplex)  
10Base-T (full-duplex)  
10 Mb/s  
20 Mb/s  
100Base-TX (half-duplex) 100 Mb/s  
100Base-TX (full-duplex) 200 Mb/s  
1000Base-T (full-duplex, 2000 Mb/s  
uplink ports only)  
Cable support  
10Base-T  
Categories 3, 5, or 6 UTP; up to 328 ft (100 m)  
Category 5 or 6 UTP; up to 328 ft (100 m)  
100Base-TX  
1000Base-T (uplink ports Category 5 or 6 UTP; up to 328 ft (100 m)  
only)  
© Copyright 2005 Hewlett-Packard Development Company, L.P.  
The information contained herein is subject to change without notice.  
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation.  
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and  
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial  
errors or omissions contained herein.  
DA - 11903  
North America — Version 5 — May 20, 2005  
Page 18  

Hanns G HW 216DPB User Manual
Garland ECO E 10 E User Manual
Epson MF1436 02 User Manual
Envision Peripherals Computer Monitor User Manual
DoubleSight Displays Computer Monitor DS 70U User Manual
Cypress Perform CY7C68013 User Manual
CTX PV720A User Manual
Creative Labs Sound Blaster Audigy 2ZS User Manual
American Audio 4 GB SD Card User Manual
Acer 41L1700 786 7A User Manual