Frymaster GSMS User Manual

Frymaster, a member of the Commercial Food Equipment Service Association, recommends  
using CFESA Certified Technicians.  
NOVEMBER 2001  
24-Hour Service Hotline 1-800-551-8633  
` 8 1 9 5 3 1 1 ~  
GAS COOKERS GSMS, GBC AND GC  
INSTALLATION AND OPERATION MANUAL  
TABLE OF CONTENTS  
CHAPTER 1: General Information  
1.1 Applicability and Validity..................................................................................................1-1  
1.2 Parts Ordering and Service Information ............................................................................1-1  
1.3 Safety Information .............................................................................................................1-2  
1.4 European Community (CE) Specific Information .............................................................1-2  
1.5 Equipment Description ......................................................................................................1-2  
1.6 Installation, Operating, and Service Personnel..................................................................1-3  
1.7 Definitions..........................................................................................................................1-3  
1.8 Shipping Damage Claim Procedure...................................................................................1-4  
CHAPTER 2: Installation Instructions  
2.1 General Installation Requirements.....................................................................................2-1  
2.2 Caster/Leg Installation.......................................................................................................2-3  
2.3 Pre-Connection Preparations .............................................................................................2-4  
2.4 Connection to Gas Line .....................................................................................................2-6  
2.5 Converting to Another Gas Type.......................................................................................2-8  
CHAPTER 3: Operating Instructions  
3.1 Introduction........................................................................................................................3-1  
3.2 Operating Instructions........................................................................................................3-2  
3.3 Shutting the Cooker Down.................................................................................................3-4  
CHAPTER 4: Preventive Maintenance  
4.1 Daily Preventive Maintenance...........................................................................................4-1  
4.2 Cleaning the Gas Valve Vent Tube ...................................................................................4-2  
4.3 Cleaning and Adjusting the Combustion Air Blower........................................................4-2  
4.4 Adjusting the Burner Gas Pressure....................................................................................4-4  
4.5 Measuring Flame Current ..................................................................................................4-5  
4.6 Controller Simmer Mode Adjustment ...............................................................................4-5  
CHAPTER 5: Operator Troubleshooting  
5.1 Introduction........................................................................................................................5-1  
5.2 Operator Troubleshooting Guides......................................................................................5-2  
5.3 Wiring Diagram .................................................................................................................5-5  
5.4 Replacing the Controller or Controller Wiring Harness....................................................5-6  
i
GAS COOKERS GSMS, GBC, AND GC  
INSTALLATION AND OPERATION MANUAL  
CHAPTER 1: GENERAL INFORMATION  
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE  
1.1  
Applicability and Validity  
The GSMS/GBC/GC model family has been approved by the European Union for sale and  
installation in the following EU countries AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL,  
NO, PT, AND SE.  
This manual is applicable to and valid for all GSMS/GBC/GC units sold in English-speaking  
countries, including those in the European Union. Where conflicts exist between instructions  
and information in this manual and local or national codes of the country in which the  
equipment is installed, installation and operation shall comply with those codes.  
This appliance is only for professional use and shall be used by qualified personnel only, as  
defined in Section 1.7.  
1.2  
Parts Ordering and Service Information  
In order to assist you quickly, the Frymaster Factory Authorized Service Center (FASC) or Service  
Department representative requires certain information about your equipment. Most of this  
information is printed on data plate affixed to the inside of the cooker door. Part numbers are found  
in the Installation, Operation, Service, and Parts Manual. Parts orders may be placed directly with  
your local FASC or distributor. A list of Frymaster FASCs was included with this equipment. If you  
do not have access to this list, contact the Frymaster Service Department at 1-800-551-8633 or  
1-318-865-1711.  
When ordering parts, the following information is required:  
Model Number:  
Serial Number:  
Type of Gas or Voltage:  
Item Part Number:  
Quantity Needed:  
Service information may be obtained by contacting your local FASC/Distributor. Service may also be  
obtained by calling the Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711. When  
requesting service, please have the following information ready:  
Model Number:  
Serial Number:  
Type of Gas:  
1-1  
In addition to the model number, serial number, and type of gas, please be prepared to describe the  
nature of the problem and have ready any other information that you think may be helpful in solving  
your problem.  
1.3  
Safety Information  
Before attempting to operate your unit, read the instructions in this manual thoroughly.  
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the one  
below.  
CAUTION boxes contain information about actions or conditions that may cause or result in a  
malfunction of your system.  
CAUTION  
Example of CAUTION box  
WARNING boxes contain information about actions or conditions that may cause or result in damage  
to your system, and may cause your system to malfunction.  
WARNING  
Example of a WARNING box.  
DANGER boxes contain information about actions or conditions that may cause or result in injury to  
personnel, and may cause damage to your system and/or cause your system to malfunction.  
1.4  
European Union (EU) Specific Information  
The European Union (EU) has established certain specific standards regarding equipment of this type.  
Equipment approved for use in EU countries is marked with the symbol. Whenever a conflict  
exists between CE and non-CE standards or when CE-unique requirements exist, the information or  
instructions concerned are identified by means of shadowed boxes similar to the ones below.  
Non-CE Standard  
CE Standard  
for Incoming Gas Pressures  
for Incoming Gas Pressures  
Normal (Pn)  
(mbar)(1)  
20  
Minimum (Pmin)  
Maximum (Pmax)  
(mbar)(1)  
(mbar)(1)  
Gas  
Minimum  
Maximum  
Gas  
G20  
G25  
G31  
G31  
6.0" WC  
1.62 kPa  
16.19 mbar  
14" WC  
3.48 kPa  
34.87 mbar  
17  
25  
Natural  
20 or 25  
30 or 37  
50  
20  
30  
25  
35 or 45  
57,5  
11" WC  
2.74 kPa  
14" WC  
3.48 kPa  
42,5  
Propane  
(1) mbar = 10,2mm H2O  
27.37 mbar  
34.87 mbar  
1.5  
Equipment Description  
Frymaster GSMS/GBC/GC gas cookers are specifically designed to deliver high volumes of  
cooked or blanched food automatically. All models feature a unique infrared burner system that  
1-2  
delivers 80,000 BTUs (23.4 kW – 84.4, megajoules) to cook 10 pounds (4.5kg) of dry pasta per bulk  
basket. The cooker can also be used to reheat up to 12 10-ounce (0.28kg) packages of pre-cooked  
food at a time. The cookpot measures 18 x 24 x 8 inches (457 x 610 x 203 mm) and holds 2.7  
gallons (48-liters) of water.  
Model Comparison:  
GSMS: The “Gas Spaghetti Magic System” consists of a gas cooker and rinse tank  
combination. The unit is equipped with a programmable controller that controls water  
temperature, water level, and cooking times. A swing-away water faucet is standard. An  
automatic basket lift system lowers and raises either bulk or individualized portions of pasta or  
other food products according to times programmed by the operator. Options include  
automatic water filling (Autofill) and starch skimming (Autoskim). The Autofill feature  
maintains the cookpot water level approximately 11/4-inch (32mm) below the overflow drain.  
The Autoskim feature sprays water on the surface of the water, forcing starch to the overflow  
drain. This eliminates loss of cooking time associated with removing excess starch buildup. It  
also keeps the water in the cookpot at the optimum level by replacing water evaporated  
during the cooking process. The Autoskim feature also saves energy since there is no need to  
refill and reheat the cookpot periodically. The cookpot is safeguarded against over filling and  
boilover by a large overflow drain. SD” following the model designation indicates a stainless  
steel cookpot and door, and enameled cabinet. SC” following the model designation  
indicates all stainless steel components.  
GBC/GC: These standalone cookers are essentially the same as the GSMS, but without the  
built-in rinse tank. GBC models have an automatic basket lift and optional automatic water  
filling and starch skimming. GC models have no basket lifts and no automatic water filling  
and starch skimming options. The cookpot in both is safeguarded against over filling and  
boilover by a large overflow drain. SD” following the model designation indicates a stainless  
steel cookpot and door, and an enameled cabinet. SC” following the model designation  
indicates all stainless steel components.  
1.6  
Installation, Operating, and Service Personnel  
All installation and service on Frymaster equipment must be performed by qualified, certified,  
licensed, and/or authorized installation or service personnel, as defined in Section 1.7.  
1.7  
Definitions  
QUALIFIED INSTALLATION PERSONNEL  
Qualified installation personnel are individuals, firms, corporations, and/or companies which, either in  
person or through a representative, are engaged in and are responsible for the installation of gas-fired  
appliances. Qualified personnel must be experienced in such work, be familiar with all gas  
precautions involved, and have complied with all requirements of applicable national and local codes.  
QUALIFIED OPERATING PERSONNEL  
Qualified operating personnel are those who have carefully read the information in this manual and  
have familiarized themselves with the equipment functions, or who have had previous experience with  
the operation of the equipment covered in this manual.  
1-3  
QUALIFIED SERVICE PERSONNEL  
Qualified service personnel are those who are familiar with Frymaster equipment and who have been  
authorized by Frymaster Corporation to perform service on Frymaster equipment. All authorized  
service personnel are required to be equipped with a complete set of service and parts manuals, and to  
stock a minimum amount of parts for Frymaster equipment. A list of Factory Authorized Service  
Centers (FASC) was included with the cooker when shipped from the factory. Failure to use quali-  
fied service personnel will void the Frymaster Warranty on your equipment.  
1.8  
Shipping Damage Claim Procedure  
Your Frymaster equipment was carefully inspected and packed before leaving the factory. Thetrans-  
portation company assumes full responsibility for safe delivery upon its acceptance of the equipment  
for transport.  
What to do if your equipment arrives damaged:  
1. File a claim for damages immediately, regardless of the extent of damages.  
2. Inspect for and record all visible loss or damage, and ensure that this information is noted on  
the freight bill or express receipt and is signed by the person making the delivery.  
3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be re-  
corded and reported to the freight company or carrier immediately upon discovery. A concealed  
damage claim must be submitted within 15 days of the date of delivery. Ensure that the shipping  
container is retained for inspection.  
FRYMASTER DOES NOT ASSUME RESPONSBILITY FOR DAMAGE OR LOSS  
INCURRED IN TRANSIT.  
1-4  
GAS COOKERS GSMS, GBC, AND GC  
INSTALLATION AND OPERATION MANUAL  
CHAPTER 2: INSTALLATION INSTRUCTIONS  
2.1  
General Installation Requirements  
Qualified, licensed, and/or authorized installation or service personnel, as defined in Section  
1.7 of this manual, should perform all installation and service on Frymaster equipment.  
Conversion of this appliance from one type of gas to another should only be performed by  
qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.7  
of this manual.  
Failure to use qualified, licensed, and/or authorized installation or service personnel (as  
defined in Section 1.7 of this manual) to install, convert to another gas type or otherwise  
service this equipment will void the Frymaster warranty and may result in damage to the  
equipment or injury to personnel.  
Where conflicts exist between instructions and information in this manual and local or  
national codes or regulations, installation and operation shall comply with the codes or  
regulations in force in the country in which the equipment is installed.  
Upon arrival, inspect the cooker carefully for visible or concealed damage. (SeeShipping Damage  
Claim Procedure in Chapter 1.)  
CLEARANCE AND VENTILATION  
The cooker(s) must be installed with 6 inches (150mm) clearance at both sides and back when  
installed adjacent to combustible construction; no construction; no clearance is required when  
installed adjacent to noncombustible construction. A minimum of 24 inches (600mm) clearance  
should be provided at the front of the cooker. To provide the airflow necessary for good combustion  
and burner operation, the areas surrounding the cooker front, sides, and rear must be kept clear and  
unobstructed.  
DANGER  
This appliance must be installed with sufficient ventilation to prevent the occurrence  
of unacceptable concentrations of substances harmful to the health of personnel in  
the room in which it is installed.  
CE Standard  
Required airflow for the combustion air supply is 2m3/h per kW.  
One of the most important considerations of efficient cooker operation is ventilation. Cookers must  
be installed in an area with an adequate air supply and adequate ventilation. Make sure the cooker is  
2-1  
installed so that products of combustion are removed efficiently, and that the kitchen ventilation sys-  
tem does not produce drafts that interfere with proper burner operation.  
The cooker flue opening must not be placed close to the intake of the exhaust fan, and the cooker  
must never have its flue extended in a chimney” fashion. An extended flue will change the  
combustion characteristics of the cooker, causing longer recovery time. It also frequently causes  
delayed ignition.  
When installed beneath a ventilation hood, adequate distance must be maintained from the flue outlet  
of the cooker to the lower edge of the ventilation filter bank. Filters should be installed at an angle of  
45° with a drip tray placed beneath the lowest edge of the filter. For U.S. installation, NFPA standard  
No. 96 states, “ A minimum distance of 18 inches (450mm) should be maintained between the flue  
outlet and the lower edge of the filter.”  
For installations in other than the United States, installers should contact the appropriate local or  
national agency for information on the construction and installation of ventilating hoods.  
ELECTRICAL GROUNDING REQUIREMENTS  
All electrically operated appliances must be grounded in accordance with all applicable national and  
local codes, and where applicable, CE codes. A wiring diagram is located on the inside of the cooker  
door. Refer to the rating plate on the inside of the cooker door for the proper voltages.  
DANGER  
If this appliance is equipped with three-prong (grounding) plug, it must be plugged  
directly into properly grounded receptacle. Do not cut or remove the grounding  
prong from the plug.  
DANGER  
This equipment requires electrical power for operation.  
Place the gas control valve in the OFF position in case of a prolonged power outage.  
Do not attempt to use the equipment during a power outage.  
NATIONAL CODE REQUIREMENTS  
GSMS/GBC/GC cookers are manufactured to use the type of gas specified on the rating plate. The  
rating plate is attached to the inside of the cooker door. Connect a cooker only to the type of gas  
indicated on the rating plate.  
Installation shall be made with a gas connector that complies with the national and local codes or  
regulations in force in the country in which the appliance is being installed. Quick-disconnect devices,  
if used, shall likewise comply with the national and local codes or regulations in force in the country  
in which the appliance is being installed  
When installing GSMS/GBS/GC cookers in theUNITED STATES, the installation must conform to  
the latest edition of the Nation Fuel Gas Code, ANSI Z223.1. In addition, installation must comply  
2-2  
with all local codes. In CANADA, installation must conform to Standard CAN/CGA-B149.1 or  
CAN/CGA-B149.2, Installation Codes for Gas Burning Appliances and Equipment. In addition,  
installation must comply with all local codes. InAUSTRALIA, this appliance must be installed by an  
authorized person in accordance with these instructions, local gas and electrical regulations, and the  
requirements of AA601, Installation Requirements for Gas Burning Appliances.  
For countries not specifically listed above, installation shall comply with the national and local codes  
or regulations in force in the country in which the appliance is being installed.  
FCC COMPLIANCE  
The user is cautioned that any changes or modifications to Frymaster controllers not expressly  
approved by the party responsible for compliance could void the users authority to operate the  
equipment.  
Frymaster controllers have been tested and found to comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC rules. While these devices are verified as Class A devices,  
they have been shown to meet the Class B limits. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used  
in accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of the equipment in residential areas is likely to cause harmful interference in which case  
the user will be required to correct the interference at his own expense. If necessary, the user should  
consult the dealer or an experience radio and television technician for additional suggestions. The  
user may find the booklet “How to Identify and Resolve Radio-TV Interference Problems” helpful. It  
is prepared by the Federal Communications Commission and is available form the U.S. Government  
Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.  
2.2  
Caster or Leg Installation  
Depending upon the specific configuration ordered your cooker may have been shipped without  
installed casters or legs. If casters or legs are installed, you may skip this section and proceed to  
Section 2.3, Pre-Connection Preparations.  
If your cooker requires the installation of casters or legs, install them in accordance  
with the instructions included in your accessory package.  
2-3  
2.3  
Pre-Connection Preparations  
DANGER  
Do not connect cooker to gas supply before completing each step in this section.  
After the cooker has been positioned under the exhaust hood, ensure the following has been  
accomplished:  
1.  
Adequate means must be provided to limit the movement of cookers without depending upon  
the gas line connections. If a flexible gas hose is used, a restraining cable must be connected  
at all times when the cooker is in use. The restraining cable and installation instructions are  
packed with the flexible hose in the accessories box that was shipped with your unit.  
2.  
Single unit cookers (GBS/GC) must be stabilized by installing restraining chains on cooker  
equipped with casters or anchor straps on cooker equipped with legs. Follow the instruction  
shipped with the casters/legs to properly install the chains or straps.  
DANGER  
Do not attach an apron drain board to a single cooker. The cooker may become  
unstable, tip over, and cause injury. The appliance area must be free and clear of  
combustible material at all times.  
3.  
Level cookers equipped with legs by screwing out the legs approximately 1 inch then adjuts-  
ing them so that the cooker is level and at the proper height in the exhaust hood.  
NOTE: There are no built-in leveling devices on cookers equipped with casters. The floor  
where the cooker is to be installed must be level.  
4.  
5.  
For GSMS and GBC units, install the basket lift arms onto the rods (located at the top rear of  
the cabinet), ensuring that the lift arms are guided by the basket lift rollers.  
Connect the water supply to the faucet and, on units with the Autofill option, the water  
solenoid valve. (The valve is located on the lower frame behind the doorpost.)  
CAUTION  
Before connecting the water supply to units equipped with solenoid valves, purge  
the water line to ensure there is no trash in the line.  
DANGER  
The maximum allowable incoming water pressure to the regulator for all units is  
80 PSI (56.3 kg/cm2).  
The maximum allowable incoming water temperature for all units is 180°F (82°C).  
NOTE: Either hot or cold water supplies may be connected to the water solenoid valve. However,  
connecting to a hot water supply will minimize the amount of time required to attain operating  
temperature when filling the cooker with fresh water.  
NOTE: In order for the water level sensors to work properly, a certain amount of mineral content is  
necessary in the water. For that reason, purified, deionized, or highly filtered water should not be  
used.  
2-4  
6.  
7.  
Connect the desired drain plumbing to the 1¼–inch drain valve.  
Test the cooker electrical system:  
a. Plug the cooker electrical cord into a grounded electrical receptacle of appropriate voltage.  
(Check the rating plate on the cooker door to determine the proper voltage).  
b. Place the power switch in the ON position and verify that the display indicates –LO.  
c. Place the cooker power switch in the OFF position. Verify that the display is blank.  
8. Refer to the rating plate on the inside of the cooker door to verify that the cooker is configured  
for the types of gas being supplied before connecting the quick-disconnect device or piping from  
the gas supply line.  
9. Refer to the table below to verify the minimum and maximum gas supply pressures for the type of  
gas being used.  
CE Standard  
for Incoming Gas Pressures  
Normal (Pn)  
(mbar)(1)  
20  
Minimum (Pmin)  
Maximum (Pmax)  
Gas  
G20  
G25  
G31  
G31  
(mbar)(1)  
(mbar)(1)  
17  
25  
20 or 25  
30 or 37  
50  
20  
30  
25  
35 or 45  
57,5  
42,5  
(1) mbar = 10,2mm H2O  
References for CE Standard are Tables 6 and A.2 of EN 203-1:1993  
Non-CE Standard  
for Incoming Gas Pressures  
Gas  
Minimum  
Maximum  
6.0" WC  
1.62 kPa  
14" WC  
3.48 kPa  
Natural  
16.19 mbar  
34.87 mbar  
11" WC  
2.74 kPa  
14" WC  
3.48 kPa  
Propane  
27.37 mbar  
34.87 mbar  
2-5  
2.4  
Connection to the Gas Line  
The GSMS/GBC/GC family of gas cookers has been approved for use with natural and propane (LP)  
gas. The cookers in this family have also received the mark for the countries and gas categories  
indicated in the accompanying table.  
CE Standard  
The nominal heat input (Qn) is 21kW except for AT, DE, LU and for category 3B/P under 50 mbar,  
which is 23kW.  
CE Approved Gas Categories by Country  
COUNTRIES  
CATEGORIES  
GAS  
G20  
PRESSURE (mbar)  
20  
50  
AUSTRIA (AT)  
II  
2H3B/P  
G31  
I 2E(R)B  
I3+  
G20, G25  
G31  
20, 25  
37  
BELGIUM (BE)  
DENMARK (DK)  
G20  
20  
II 2H3B/P  
II 2Esi3+  
G31  
30  
G20,G25  
G31  
20, 25  
37  
FRANCE (FR)  
G20/G25  
G31  
20, 25  
50  
II  
2Esi3P  
G20  
20  
FINLAND (FI)  
II  
2H3B/P  
G31  
30  
G20/G25  
G31  
20  
II 2ELL3B/P  
I3P  
GERMANY (DE)  
50  
G31  
50  
G20  
20  
GREECE (GR)  
ITALY (IT)  
II 2H3+  
G31  
37  
G20  
20  
II 2H3+  
II 2H3+  
G31  
37  
G20  
20  
IRELAND (IE)  
LUXEMBOURG (LU)  
G31  
37  
G20  
20  
II  
2E3B/P  
G31  
50  
G25  
25  
II 2L3P  
G31  
50  
NETHERLANDS (NL)  
G25  
25  
II 2L3B/P  
I 3B/P  
G31  
30  
NORWAY (NO)  
G31  
30  
G20  
20  
PORTUGAL (PT)  
II 2H3+  
G31  
37  
G20  
20  
II 2H3+  
G31  
G37  
20  
SPAIN (ES)  
G20  
II  
2H3P  
G31  
37, 50  
20  
G20  
SWEDEN (SE)  
II  
2H3B/P  
G31  
30  
G20  
20  
UNITED KINGDOM (GB)  
II 2H3+  
G31  
37  
2-6  
The size of the gas line used for installation is very important. If the line is too small, the gas pressure  
at the burner manifold will be low. This may cause slow recovery and delayed ignition. Frymaster  
recommends the incoming gas supply line be a minimum of 1 ½” (38mm) in diameter. Refer to the  
chart below for the minimum sizes of connection piping.  
Gas Connection Pipe Sizes  
(Minimum incoming pipe size should be 1½” (38 mm))  
Gas  
Natural  
Single Unit  
¾” (19 mm)  
½” (13 mm)  
2-3 Units  
1” (25 mm)  
¾” (19 mm)  
Propane  
For distances of more than 20 feet (6m) and/or more than four fittings  
or elbows, increase the connection by one pipe size.  
Before connecting new pipe to your unit, the pipe must be thoroughly blown out to remove any  
foreign particles. If these foreign particles get into the burner and controls, they will cause improper  
and sometimes dangerous operation.  
1. Connect the quick-disconnect hose to the cooker quick-disconnect fitting at the rear of the cooker  
and to the building gas line.  
NOTE: Some cookers are configured for a rigid connection to the gas supply line. These units  
must be connected to the gas supply line at the rear of the unit using fittings approved for that  
purpose by the appropriate regulatory agency of the county in which the appliance is installed.  
NOTE: When using thread compound, use very small amounts on male threads only. Use a pipe  
thread compound that is not affected by the chemical action of LP gases (i.e. propane, G31)  
(Loctite™ PST56765 Sealant is one such compound).DO NOT apply compound to the first two  
threads. This will ensure that the burner orifices and control valve do not become clogged.  
2. Open the gas supply to the cooker and check all piping, fittings, and gas connections for leaks. A  
soap solution should be used for this purpose.  
DANGER  
Never use matches, candles, or any other ignition source to check for leaks. If gas  
odors are detected, shut off the gas supply to the cooker at the main shut-off valve  
and contact the local gas company or an authorized service agency for service.  
3. Close the cooker drain valve and fill the cookpot with water and detergent. Light the cooker and  
perform the boil-out procedures that are described in the Lighting Instructions” and Boiling Out  
the Cookpot” topics found in Chapter 3 of this manual.  
WARNING  
“Dry-firing” this equipment will cause damage to the cookpot. Always ensure that  
water is in the cookpot before firing your unit.  
2-7  
4. It is recommended that the burner gas pressure be checked at this time by the local gas company  
or an authorized service agent. Refer to “Check Burner Pressure” in Chapter 4 of this manual for  
the proper procedure. The accompanying tables list the burner gas pressures for the various gas  
types that can be used with this equipment.  
CE Standard for  
Non-CE Standard for  
Burner Gas Pressure  
Burner Gas Pressure  
Gas Pressure  
Natural Lacq  
(G20) under 20 mbar  
Natural Gronique*  
(G25) under 25 mbar  
Propane  
Gas  
Pressure  
7 mbar  
12 mbar  
22,2 mbar  
3.5" WC  
0.87 kPa  
Natural  
8.718 mbar  
8.25" WC  
2.05 kPa  
(G31) under 37 mbar  
* Belgian G25 = 7,0 mbar  
Propane  
20.55 mbar  
2.5  
Converting to Another Gas Type  
DANGER  
Your cooker is configured at the factory for a specific type of gas. If you desire to  
switch from one type of gas to another, specific gas-conversion components must  
be installed.  
Switching to a different type of gas without installing the proper conversion  
components may result in fire or explosion! NEVER attach your cooker to a gas  
supply for which it is not configured.  
Conversion of this appliance from one type of gas to another should only be  
performed by qualified, licensed, and/or authorized installation or service personnel,  
as defined in Section 1.7 of this manual.  
CE Gas Conversion Components  
G20 or G25 (Natural) to G31 Gas:  
Orifice: 810-1970 (2 required)  
Ignitor Kit: 826-1715 (2 required)  
Conversion Rating Label 802-2144  
G31 (Propane) to G20 or G25 Gas:  
Orifice: 810-0916 (2 required)  
Ignitor Kit: 826-1714 (2 required)  
Conversion Rating Label 802-2144  
Non-CE Gas Conversion Components  
Natural Gas to LP (Propane) Gas:  
Orifice: 810-0917 (2 required)  
Ignitor Kit: 826-1715 (2 required)  
Regulator: 807-1848 (1 required)  
Conversion Rating Label 802-2144  
LP (Propane) Gas to Natural Gas:  
Orifice: 810-0916 (2 required)  
Ignitor Kit: 826-1714 (2 required)  
Regulator: 807-1847 (1 required)  
Conversion Rating Label 802-2144  
2-8  
CE Gas Conversion Instructions  
1. Between G20- and G25- type Natural Gas, adjust the gas pressure at the gas valve regulator.  
(Refer to the CE Standard for Burner Gas Pressure Table on Page 2-7.) Do not change the  
orifices.  
2. Between a 2nd family (G20 or G25) and a 3rd family gas (G31 Propane):  
a. Change the orifices.  
b. Change the ignitors.  
c. Adjust the incoming gas pressure for the new gas. (Refer to the CE Standard for Incoming  
Gas Pressure table on Page 2-5).  
d. Adjust the burner gas pressure at the gas valve regulator. (Refer to the CE Standard for  
Burner Gas Pressure table on Page 2-8 and adjustment procedure in Chapter 4.)  
3. Affix the new label included with the conversion kit next to the existing rating plate stating that  
the gas type has been converted. Remove any references to the previously used gas from the  
existing rating plate. Label PN 802-2144  
4. If the destination language changes, replace the labels. (You must contact your local service  
agency or KES for label kit. The language of reference is indicated on the corner of the label.)  
Non-CE Gas Conversion Instructions  
1. Change the orifices.  
2. Change the ignitors.  
3. Install the regulator kit in the gas valve in accordance with the instructions furnished with the kit.  
4. Adjust the incoming gas pressure for the new gas. (Refer to the Non-CE Standard for Incoming  
Gas Pressure table on Page 2-5.)  
5. Adjust the gas pressure at the gas valve regulator. (Refer to the Non-CE Standard for Burner  
Gas Pressure table on Page 2-8 and adjustment procedure in Chapter 4.)  
6. Affix the new label included with the conversion kit next to the existing rating plate stating that  
the gas type has been converted. Remove any references to the previously used gas from the  
existing rating plate. Label PN 802-2144  
7. If the destination language changes, replace the labels. (You must contact your local service  
agency or KES for a label kit. The language of reference is indicated on the corner of the label.)  
2-9  
GAS COOKERS GSMS, GBC, AND GC  
INSTALLATION AND OPERATION MANUAL  
CHAPTER 3: OPERATING INSTRUCTIONS  
1
6
10  
2
3
4
5
8
9
7
1
2
3
4
5
Numeric Keypad  
6
7
8
9
Skim Switch  
Timer Start Switch  
Simmer Mode Switch  
Simmer Mode Indicator  
Boil Mode Indicator  
Boil Mode Switch  
Power Switch  
LED Display  
10 Trouble Light  
3.1  
Introduction  
The Spaghetti Magic Controller allows the operator to specify a cook time in minutes and seconds,  
then initiate a cooking cycle. This controller is available in three configurations. The standard  
configuration has both automatic filling (Autofill) and automatic skimming (Autoskim) features.  
Options include Autofill only, or neither Autofill nor Autoskim.  
When in the BOIL mode, the burners are lit at all times. It is used when actually cooking pasta.  
The SIMMER mode feature maintains the water temperature just below boiling, which conserves  
energy and water. This feature is designed for rethermalizing previously cooked packaged products  
and for keeping the cooker in standby.  
The AUTOSKIM and SKIM features are independent of each other. The AUTOSKIM feature, on  
units so equipped, adds water for approximately 3 seconds once a minute. It cannot be turned off.  
The SKIM feature, when activated by pressing the skim button on the controller, delivers a  
continuous spray of water for approximately 2 minutes, then stops until the button is again pressed.  
In both cases, the purpose is to cause the water in the cookpot to overflow into the drain, carrying  
floating starch with it. (A buildup of starch reduces the efficiency of the cooker and can cause  
erroneous temperature and water level sensing.)  
3-1  
LOW WATER SENSING automatically closes the gas valve (thereby extinguishing the burner  
flame) if the water in the cookpot drops too low. When the water level in the cookpot is below the  
low-water sensor, such as when draining and cleaning the cookpot, the controller display will readLO.  
NORMAL WATER LEVEL SENSING, on units configured with the Autofill feature,  
automatically adds water during or after a cooking cycle if the water in the cookpot drops to a level  
lower than approximately 1¼-inch (32 mm) below the overflow drain. With this automatic filling  
feature, the water level does not have to be continuously monitored. The cookpot always has the  
correct amount of water.  
FAHRENHEIT OR CELSIUS TEMPERATURE DISPLAY  
There are two versions of the SMS Controller: one that can be toggled between Fahrenheit and  
Celsius temperature display, and one that cannot. To determine which version you have, turn the  
controller off by pressing the power  
switch. The display will go blank. Press the Simmer  
(right thermometer icon) switch. If Code appears in the display, the temperature display can be  
changed. If not, the display cannot be changed.  
1. If Code appears in the display, press 1, 6, 5, 8. The display will be toggled from Fahrenheit to  
Celsius or from Celsius to Fahrenheit.  
2. Press the Boil  
(left thermometer icon) switch to display the cookpot temperature. If an F  
follows the temperature, the display is in Fahrenheit; if aC follows the temperature, the display is  
in Celsius.  
3.2 Operating Instructions  
Before turning the cooker on, ensure that:  
·
·
·
·
·
the unit is connected to the water supply.  
the water supply is turned on  
the unit is plugged in to an appropriate outlet.  
the electrical power supply is turned on  
the gas supply is turned on.  
3.2.1 Start-up Procedure  
CAUTION  
If this is the first time the unit is being used after installation, refer also to  
Section 3.2.3, Boiling Out the Cookpot.  
1. Press the power  
switch to the ON position. If the cooker is equipped with the Autofill option,  
the cookpot will automatically begin to fill with water. If not, manually fill the cookpot using the  
faucet until the water level is above the upper water level sensor located at the left front of the  
cookpot as you face the unit. (On units with Autofill, the water will automatically shut off when  
the water in the cookpot has reached the correct level.)  
3-2  
2. On Non-CE units, turn the gas valve knob to the ON position  
(see illustration at right.) NOTE: CE gas valves do not have  
an ON/OFF knob. These valves will activate automatically  
when the controller power switch is placed in the ON position  
and the lower water level sensor is covered with water.  
The burners should light for several seconds and then go out. A  
few seconds later they should light again. This cycle will repeat  
about 10 times, at which time the burners should remain lit until  
the setpoint is reached.  
If the burners fail to light, press the power  
switch to the  
OFF position, wait 60 seconds, then repeat this step.  
3. After the burners have been lit continuously for at least 90 seconds, observe the burners through  
the burner viewports. They should display a bright orange-red glow. If a blue flame is observed,  
or if there are dark spots on a burner face, the air gas mixture requires adjustment, as explained  
below.  
NOTE: Adjusting the Air/Gas Mixture:  
On the side of the blower housing opposite the motor is a plate with one or two locking nuts.  
Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to  
open or close the air intake opening until a bright orange-red glow. Carefully hold the plate in  
position and tighten the lock nut(s).  
3.2.2 Normal Operation  
1. Turn the controller on by pressing the power  
switch.  
2. The unit will automatically enter the boil mode and the boil mode indicator will illuminate. If you  
do not intend to immediately begin cooking, press the Simmer Mode switch. The simmer  
mode indicator will illuminate. To re-enter the boil mode, press the Boil Mode switch.  
3. Enter the desired cooking time using the numeric keypad. The time entered appears in the LED  
display.  
4. When ready to initiate a cooking cycle, press the Start Timer  
switch. The basket lift (on units  
so equipped) will automatically lower the basket or portion cups into the cookpot and the LED  
display will begin to count down. At the end of the cooking cycle, an alarm will sound briefly to  
alert you and the basket lift will automatically raise the basket or portion cups out of the water.  
The display will automatically return to the previously set cooking time. If the same time is  
desired for the next batch, simply press the Start Timer switch when ready, otherwise enter the  
new cooking time before pressing the switch.  
5. To initiate the skim feature, press the Skim switch.  
3-3  
3.2.3 Boiling Out the Cookpot  
To ensure that the cooker is free of contamination from manufacture, shipping, or handling during  
installation, the cookpot must be boiled out before first use.  
1. Close the drain valve and fill the cookpot with a mixture of cold water and 1 cup of detergent.  
2. Place the unit into operation (see Section 3.2.1).  
3. Press the Simmer Mode switch  
and allow the solution to simmer for at least 1 hour.  
4. After the solution simmers for 1 hour, turn the unit off and add cold water until the solution is  
cool. Drain the solution and clean the cookpot thoroughly with a solution of dishwashing  
detergent and hot water.  
5. Rinse the cookpot at least twice by filling with clean water and draining. Dry the cookpot  
thoroughly with clean, dry towel.  
6. For units equipped with a rinse tank, clean the tank with a solution of dishwashing detergent and  
hot water. Drain the tank and dry it thoroughly with a clean, dry towel.  
3.3  
Shutting the Cooker Down  
Turn the unit off by pressing the power  
switch. If shutting down at the end of the day, place the  
gas valve in the OFF position (Non-CE units), drain and clean the cookpot (and rinse tank, if so  
equipped), and put the cookpot and rinse tank covers in place.  
3-4  
GAS COOKERS GSMS, GBC, AND GC  
INSTALLATION AND OPERATION MANUAL  
CHAPTER 4: PREVENTIVE MAINTENANCE  
4.1  
Daily Preventive Maintenance  
It is normal for a coating of starch to form on the sensors and temperature probes during operation. If the  
coating is allowed to build-up, it will adversely affect the operation of the equipment. The preventive main-  
tenance routines below should be performed at least daily to keep your equipment functioning at peak effi-  
ciency. The cookpot and rinse tank – especially the water-level sensors and the temperature probe – may  
require more frequent cleaning, depending upon the product volume.  
Inspect Equipment and Accessories for Damage  
Look for loose or frayed wires and cords, leaks, foreign material in cookpot or inside cabinet, and any  
other indications that the equipment and accessories are not ready for safe operation.  
Clean Cabinet Inside and Out  
Clean inside the cabinet with a dry, clean cloth. Wipe all accessible metal surfaces and components to re-  
move accumulations of oil, dust, or cooking residue.  
Clean the outside of the cabinet with a clean cloth dampened with dishwashing detergent, removing oil, dust,  
or cooking residue.  
DANGER  
Never attempt to clean this equipment during the cooking process or when the cook-  
pot is filled with hot water and/or food products.  
Clean Water-Level Sensors, Temperature Probe, Cookpot, and Rinse Tank  
1. Turn the equipment off and drain the cookpot (and rinse tank, if so equipped).  
2. Remove the probe cover and clean the water-level sensors and temperature probe using a  
Scotchbrite™ or similar abrasive pad and a solution of detergent and water.  
3. Using a Scotchbrite™ or similar abrasive pad and a solution of detergent and water, clean the inside of  
the cookpot (and rinse the tank, if so equipped).  
4. Rinse the cookpot (and rinse tank, if so equipped) thoroughly with clean water at least twice.  
4-1  
4.2  
Cleaning the Gas Valve Vent Tube  
This procedure should be performed at least once every 90 days.  
NOTE: This procedure is not required for cookers configured for export to CE  
countries. The gas valves on CE units are not equipped with vent tubes.  
1. Set the power switch and the gas valve to the OFF position.  
2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for  
ease in removal.  
3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any obstruction.  
4. Remove the wire and blow through the tube to ensure it is clear.  
5. Reinstall the tube and bend it so that the opening is pointing downward.  
4.3  
Cleaning and Adjusting the Combustion Air Blower  
1. Unplug the cooker. Mark and disconnect the four wires running from the motor at the inline connectors.  
2. Remove the four nuts and bolts securing the blower to mounting bracket. Remove the blower from the  
cooker.  
3. Remove the three fasteners that secure the blower motor assembly to the blower housing, and separate  
the two components.  
Remove these fasteners.  
(On black-colored FASCO  
blowers there are three  
nuts. On silver-colored  
KOOLTRONICS blowers  
there are three screws.)  
4-2  
4. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or detergent on  
the blower wheel and the blower housing. Allow it to soak for five minutes. Rinse the wheel and hous-  
ing with hot tap water, then dry with a clean cloth.  
Wrap the motor and  
wires with plastic wrap  
or a plastic bag.  
BLOWER HOUSING  
BLOWER WHEEL  
5. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor assembly  
and blower housing. Reinstall the blower assembly in the cooker and reconnect the wires disconnected  
in Step 1.  
4. Reinstall the blower shield or shield assembly.  
5. Light the cooker in accordance with the procedure described in Chapter 3, Section 3.1.  
6. After the burners have been lit for at least 90 seconds, observe the flames through the burner viewing  
ports. The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with  
the applicable table on page 4-4 and the burners display a bright orange-red glow. If a blue flame is  
observed, or if there are dark spots on a burner face, the air/gas mixture requires adjustment.  
On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loosen  
the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open or close  
the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and  
tighten the locking nut(s).  
4-3  
TYPICAL NON-CE BLOWER ASSEMBLY  
TYPICAL CE BLOWER ASSEMBLY  
4.4  
Adjusting the Burner Gas Pressure  
DANGER  
Frymaster recommends that ONLY qualified service personnel perform this task.  
1. On Non-CE cookers, ensure that the gas valve knob is in the OFF position.  
2. Remove the pressure tap plug from the gas valve assembly.  
Pressure Tap Plug  
Typical Non-CE  
Valve Assembly  
Typical CE  
Valve Assembly  
3. Insert the fitting for a gas pressure-measuring device into the pressure tap hole  
4. On NON-CE cookers only, place the gas valve in the ON position.  
5. Place the power switch in the ON position. When the burner has lit and burned steadily for at least one  
minute, compare the gas pressure reading to the pressure for the corresponding gas in the appropriate  
table below.  
4-4  
CE Standard for  
Burner Gas Pressure  
Non-CE Standard for  
Burner Gas Pressure  
Gas  
Natural Lacq  
Pressure  
Gas  
Pressure  
7 mbar  
12 mbar  
22,2 mbar  
(G20) under 20 mbar  
Natural Gronique*  
(G25) under 25 mbar  
Propane  
3.5" WC  
0.87 kPa  
Natural  
8.718 mbar  
8.25" WC  
2.05 kPa  
(G31) under 37 mbar  
* Belgian G25 = 7,0 mbar  
Propane  
20.55 mbar  
6. To adjust the burner gas pressure, remove the cap from the gas valve regulator and use a flat-tipped  
screwdriver to adjust the regulator to obtain the correct pressure.  
Non-CE  
Valve  
Later Model  
CE Valve  
Earlier Model CE Valve  
GAS VALVE REGULATOR CAP  
7. Place the power switch (and the gas valve in non-CE cookers) in the OFF position. Remove the fitting  
from the pressure tap hole and reinstall the pressure tap plug.  
4.5  
Measuring Flame Current  
When the burner flame is properly adjusted, it will produce a current between 2.5 µA and 3.5 µA. Flame  
current is measured by placing a microamp (not milliamp) meter in series with the white sensing wire on one  
of the ignitors. This is accomplished as follows:  
1. Place the power switch in the OFF position.  
2. Disconnect the sensing wire from one of the burner ignitors and connect it to the positive lead of the  
meter. Connect the negative lead of the meter to the terminal from which the sensing wire was re-  
moved.  
3. Place the power switch in the ON position to light the burners. After the cookpot temperature reaches  
2000F (930C), wait at least one minute before checking the reading. NOTE: The closer the unit is to  
normal operation temperature, the more accurate the reading will be.  
4.6  
Controller Simmer Mode Adjustment  
NOTE: The controller simmer temperature is adjustable form 185°F to 215°F (85°C to 102°C). There are  
two versions of this controller; one is adjusted by programming, the other is manually adjusted. To  
4-5  
determine which version of the controller you have, turn the controller off by pressing the power  
switch.  
The display will go blank. Press the Simmer Mode (right thermometer icon) switch. If Code appears in  
the display, the setpoint is changed via programming; if not, skip to Manual Adjustment on the next  
page.  
1. Press 1, 6, 5, 0 to enter the programming mode. The currently programmed simmer setpoint will be  
displayed. If the setpoint is not correct, enter the desired setpoint (for example, press 2, 0, 0 to pro-  
gram the simmer setpoint to 200°).  
2. Press the Simmer Mode  
switch again to lock the setpoint, then press the power  
switch to turn  
the controller on and return to the normal operating mode.  
Manual Adjustment  
1. With the unit in the simmer mode, place the tip of a good grade thermometer near the temperature  
probe and determine the actual water temperature in degrees Fahrenheit. If the temperature is within  
±5°F (2°C) of the desired simmer temperature, nothing more needs to be done. If it is not within ±5°F  
(2°C) of the desired temperature, perform Steps 2 through 5.  
2. With the unit in the Simmer Mode, open the control panel by removing the screws in the upper corners  
and tilting the panel out.  
3. Remove the black rubber plug from the top of the controller housing.  
4. Using a small, flat-tipped screwdriver, turn the adjusting screw to change the simmer setpoint. A ¼  
turn will change the setpoint about 10°F (4°C). (You will have to experiment with the direction of  
rotation to determine which way to turn to raise or lower the temperature). Wait at least 5 minutes, then  
recheck actual water temperature. Repeat this step until the water temperature is within ±5°F (2°C) of  
desired temperature.  
5. Replace the plug in the controller, close the control panel, and replace the screws removed in Step 2.  
4-6  
GAS COOKERS GSMS, GBC, AND GC  
INSTALLATION AND OPERATION MANUAL  
CHAPTER 5: OPERATOR TROUBLESHOOTING  
5.1  
Introduction  
This chapter provides a reference guide to the more common problems that may occur during the  
operation of this equipment. The troubleshooting guides in this chapter are intended to help you  
correct, or at least accurately diagnose, problems with the equipment. Although the chapter covers  
the most common problems reported, you may very well encounter a problem not covered. In such  
instances, the Frymaster Technical Service Department will make every effort to help you identify  
and resolve the problem.  
When troubleshooting a problem, always use a process of elimination starting with the simplest  
solution and working through the most complex. Never overlook the obvious. Anyone can forget to  
plug a cord into a receptacle or open the valve on the water supply line. Don’t assume that you are  
exempt from such occurrences. Most importantly, try to establish a clear idea of why a problem has  
occurred. Part of your corrective action involves taking steps to ensure that it doesn’t happen again.  
If a controller malfunctions because of a poor connection, check all other connections while you’re  
at it. If a fuse continues to blow, find out why. Keep in mind that failure of a small component may  
often be indicative of potential failure or incorrect functioning of a more important component or  
system.  
Some of the troubleshooting actions recommended in this chapter involve removing suspect  
controllers and substituting controllers that are known to be good. Whenever this is indicated, refer  
to Section 5.4.  
If your have doubts as to the proper action to take, do not hesitate to call the Frymaster Technical  
Service Department or your local Frymaster Factory Authorized Service Center for assistance.  
Before calling a servicer or the Frymaster HOTLINE (1-800-551-8633):  
Verify that electrical cords are plugged in and that circuit breakers are on.  
Verify that water supply valves are open and that the drain valves are fully closed.  
Verify that the main gas supply valve is open.  
DANGER  
Hot water can cause severe burns. Never attempt to move a cooker containing hot  
water or to transfer hot water from one container to another.  
DANGER  
Use extreme care when performing electrical circuit tests. Live circuits will be  
exposed.  
DANGER  
Inspection, testing and repair of electrical components should be performed only by  
qualified service personnel. The equipment should be unplugged when servicing,  
except when electrical tests are required.  
5-1  
5.2  
Operator Troubleshooting Guides  
Problem Probable Causes  
Corrective Action  
A. Turn the controller OFF. Open  
the control panel by removing  
the screws in the upper corners.  
If there are two ignition mod-  
ules, check for blown 2-amp  
fuses and replace as necessary.  
Close the control panel and press  
the power switch. Wait at least  
4 minutes.  
A. Ignition module lockout (the  
burners failed to light within 4  
seconds).  
Indicator: Red trouble light on  
control panel is illuminated.  
BURNERS DO NOT  
LIGHT  
B. Dirty water level sensors. (If the B. Remove the probe block cover  
(Main gas supply  
valve verified to be  
open, the gas valve in  
Non-CE units is  
verified to be ON, and  
power switch is  
computer does not sense sufficient  
water in the cookpot, it will not  
allow the burners to fire.)  
and clean the sensors using a  
Scotchbrite™ or similar pad and  
a solution of detergent and  
water.  
C. Failed controller.  
C. Order replacement controller  
from FASC or distributor.  
verified to be ON.)  
Test: If another controller known  
to be working is available, substi-  
tute the working controller for the  
suspect controller. If the burners  
light, the controller has failed.  
D. Failed ignition module or gas  
valve, or broken or loose wiring.  
C. Call FASC.  
A. Dirty water level sensors. (If the A. Remove the probe block cover  
sensors are dirty, they may cause  
the controller to “think” the  
cookpot is full.)  
and clean the sensors using a  
Scotchbrite™ or similar pad and  
a solution of detergent and  
water.  
ON UNIT WITH  
AUTOFILL,  
B. Failed controller.  
B. Order replacement controller  
from FASC or distributor.  
COOKPOT DID  
NOT FILL WHEN  
UNIT WAS  
TURNED ON  
(Water supply to unit  
verified to be ON.)  
Test: If another controller known  
to be working is available,  
substitute the working controller  
for the suspect controller. If the  
unit begins to fill, the controller  
has failed.  
C. Shorted upper water level sensor, C. Call FASC.  
failed water solenoid valve, or  
loose/broken wiring.  
5-2  
Problem  
Probable Causes  
Corrective Action  
A. Dirty water level sensors. (If the A. Remove the probe block cover  
water level sensors are dirty, the  
controller may not “know” the pot  
is full.)  
and clean the sensors using a  
Scotchbrite™ or similar pad and  
a solution of detergent and  
water.  
ON UNIT WITH B. Insufficient mineral content in  
B. Add -cup of baking soda to the  
water in the cookpot as the unit  
fills. DO NOT USE SALT!  
Doing so will damage the  
cookpot. Avoid using distilled,  
highly filtered, or deionized  
water.  
AUTOFILL,  
WATER DID NOT  
SHUT OFF WHEN  
COOKPOT WAS  
FULL  
water. (Pure water is not a  
conductor of electricity. The water  
level sensors actually sense  
impurities in the water, not the  
water itself.)  
C. Failed upper water level sensor,  
loose or broken upper water level  
sensor wiring, failed water sole-  
noid valve.  
C. Call FASC.  
A. Failed controller. (If the  
AUTOFILL functions correctly,  
the only cause possible is a failed  
controller.)  
A. Order replacement controller  
from FASC or distributor.  
AUTOSKIM DOES  
NOT WORK  
(AUTOFILL functions  
correctly.)  
A. Failed controller.  
A. Order replacement controller  
from FASC or distributor.  
WATER WILL NOT  
BOIL  
Test: If another controller known  
to be working is available,  
substitute the working controller  
for the suspect controller. If the  
unit begins to fill, the controller  
has failed.  
(Cookpot verified to  
be full of water with  
Boil Mode selected,  
i.e., left indicator is lit  
and burners are lit.)  
B. Failed temperature probe.  
A. Controller out of adjustment.  
B. Call FASC.  
A. Adjust controller in accordance  
with procedure in Chapter 4.  
B. Order replacement controller  
from FASC or distributor.  
B. Failed controller.  
Test: If another controller known  
to be working is available,  
substitute the working controller  
for the suspect controller. If the  
unit begins to fill, the controller  
has failed.  
WATER BOILS IN  
SIMMER MODE  
B. Failed/shorted temperature probe. C. Call FASC.  
5-3  
Problem  
Probable Causes  
A. Controller out of adjustment.  
Corrective Action  
A. Adjust controller in accordance  
with procedure in Chapter 4.  
B. Order replacement controller  
from FASC or distributor.  
B. Failed controller.  
WATER  
TEMPERATURE IS  
TOO LOW IN  
Test: If another controller known  
to be working is available,  
substitute the working controller  
for the suspect controller. If the  
unit begins to fill, the controller  
has failed.  
SIMMER MODE  
C. Open temperature probe or loose C. Call FASC.  
probe wire.  
A. Lack of lubrication on basket lift A. Lubricate lifter rods with a  
BASKET LIFT  
MOVEMENT IS  
JERKY OR NOISY  
rods.  
lightweight lubricant.  
5-4  
5.3  
Wiring Diagram  
5-5  
5.4  
Replacing the Controller  
1. Disconnect the cooker from the electrical supply.  
2. Remove the two screws in the upper corners of the control panel and swing the panel open from  
the top, allowing it to rest on its hinge tabs.  
3. Disconnect the wiring harness from the back of the controller.  
4. Disconnect the ground wire from the controller. Remove the control panel by lifting it from the  
hinge slots in the frame.  
5. Follow the instructions that came with the replacement controller to dismount the failed  
controller from the control panel and install the new controller.  
6. Reverse Steps 1 through 4 to complete the procedure.  
5-6  
THIS PAGE INTENTIONALLY LEFT BLANK  
Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000  
Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106  
TEL 1-318-865-1711  
FAX (Parts) 1-318-219-7140  
(Tech Support) 1-318-219-7135  
SERVICE HOTLINE  
1-800-551-8633  
819-5311  
NOVEMBER 2001  
PRINTED IN THE UNITED STATES  

Fisher Paykel FREESTANDING COOKER OR120 User Manual
Eurotech Appliances CPU 1461 User Manual
Eizo EIZO FlexScan T960 User Manual
Eizo COLOREDGE CG243W User Manual
Dell E197FP User Manual
Black Box Computer Hardware LGB424A User Manual
ATI Technologies RADEON 137 40225 20 User Manual
Asus P4U800 X User Manual
Asus Computer Hardware PC133 User Manual
Agilent Technologies HSSI WanProbe J3916A User Manual