Fisher Paykel Cooktop HI120 User Manual

(1,1) -1- 599489D izona vsisland install A2 NZGB.indd 21/7/09 2:51:59 PM  
Installation instructions  
IZONA VentSurface  
HI120 ISLAND models  
NZ AU GB IE  
Important!  
SAVE THESE INSTRUCTIONS  
The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our local  
website listed at the end of this document or contact your local Fisher & Paykel dealer.  
1
SAFETY AND WARNINGS  
Before you install the appliance, please make sure that  
the voltage (V) and frequency (Hz) indicated on the serial number plate as well as  
WARNING!  
the specifications on the rating plate on the inside of the appliance correspond to  
the voltage and frequency of the mains supply.  
the room in which the appliance is installed is well-ventilated.  
the ceiling is able to withstand the total weight (56 kg) of the appliance suspended from it.  
if the air is to be ducted, the flue is in good condition, especially if it has been out of  
use for a long period of time.  
Electrical shock hazard  
Always disconnect the appliance from the mains electricity supply before  
carrying out any servicing or maintenance operations.  
Failure to do so could result in electrical shock or death.  
WARNING!  
If the air is to be ducted, it will not be discharged into a flue that is used for  
exhausting fumes from appliances burning gas or other fuels.  
the installation will comply with laws and regulations regarding ducting waste  
gases.  
Cut Hazard  
Take care - panel edges are sharp.  
for optimal efficiency, use smooth ducting for reduced noise and increased airflow. Flexible ducting  
should only be used as a last resort.  
Failure to use caution could result in injury or cuts.  
When you install the appliance, please make sure that  
Important safety instructions!  
a suitable isolating switch is incorporated in the permanent wiring, mounted  
and positioned to comply with the local wiring rules and regulations. The switch  
must be of an approved type installed in the fixed wiring and have a contact separation in all poles  
that provide full disconnection under overvoltage category III conditions.  
it is not installed and connected to flues where other appliances are installed  
and which run off energy supplies other than electricity (eg water heaters, boilers,  
gas cookers).  
the power supply cable (type H05VV-F 3x0.75 mm2) is connected to terminals marked with  
the letters L (power line) and N (neutral) mounted on the appliance and is secured  
in position by a cable gland.  
the power supply cable is connected to a suitable and easily accessible fixed power outlet or  
isolating switch.  
the power outlet or isolating switch remains accessible after installation and the appliance can be  
disconnected from the electricity supply.  
To avoid hazard, read and follow these instructions carefully before installing or  
using this appliance.  
Please make this information available to the person installing the appliance, as it  
could reduce your installation costs.  
This appliance is to be installed and connected to the electricity supply only by a  
qualified electrician.  
Installation must comply with your local building and electricity regulations.  
Failure to install the appliance correctly could invalidate any warranty or liability  
claims.  
This appliance is designed for permanent fixture and has to be connected to the  
mains electricity supply.  
The appliance must not be installed above cookers with eye-level grills.  
The appliance is heavy, take care when lifting or handling.  
exhaust air is not discharged into a heating flue or wall cavity, unless the cavity is designed for that  
purpose.  
If you install using the external ducting through a side wall, ensure the surface area of the external  
venting grill is no smaller than 150 cm2.  
the glass and stainless steel components are handled with care. These are easily damaged if abraded  
or knocked by tools.  
(2,1) -1- 599489D izona vsisland install A2 NZGB.indd 21/7/09 2:51:59 PM  
4
PARTS SUPPLIED  
Support frame  
for vertical flue  
mounting support  
brackets (1)  
Ceiling  
4 x 50 Screws (4)  
and corresponding  
wall anchors (4)  
Vertical flue  
Aluminium  
mounting  
frame (1)  
Extendable  
flue cover (1)  
Plastic vent  
duct (1)  
4 x 16  
3.5 x 9.5  
Upper glass (1)  
mounting support  
brackets (4)  
mesh filter (1)  
Washers (4)  
Screws (46)  
Note: ducting accessories, carbon filter and the Ductless Recirculating Kit are NOT supplied with your VentSurface but need to be purchased separately. They are available from your nearest Fisher & Paykel Authorised  
5
6
VENTILATION OPTIONS  
RATING PLATE LOCATION  
Cod.  
TYPE  
SERIE  
V
BATCH  
Hz  
W
tot  
MAX  
W
W
Recirculation  
(Requires Carbon Filter, to  
1
2
3
L
L
be purchased separately  
as part of the Ductless  
External ducting  
M1  
M2  
Recirculating Kit. Contact  
your nearest Fisher & Paykel  
Authorised Service Agent or  
instructions and details.)  
External ducting  
through a side wall  
or ceiling  
Recirculation  
recirculates filtered air  
back into the kitchen  
(2,2) -1- 599489D izona vsisland install A2 NZGB.indd 21/7/09 2:51:59 PM  
SECURE MOUNTING FRAME TO CEILING & MOUNT UPPER GLASS  
7
A
B
1
6 mm holes  
x 4  
2
Ensure the washers  
provided are used  
8
ATTACH PLASTIC VENT DUCT & ASSEMBLE VERTICAL MOUNTING BRACKETS  
A
B
1
1
x 4  
2
(1,1) -2- 599489D izona vsisland install A2 NZGB.indd 21/7/09 2:52:11 PM  
9
ATTACH VERTICAL MOUNTING BRACKETS & SLIDE ON FLUE COVER  
A
B
1
2
1
2
x 16  
10  
ATTACH MOUNTING BRACKETS TO MOUNTING FRAME & ATTACH FLUE COVER  
A
B
x 8  
2
2
1
1
Important!  
VERY HEAVY: Ensure that the  
ceiling is able to withstand  
the total weight (56 kg) of the  
appliance suspended from it.  
x 4  
(2,1) -2- 599489D izona vsisland install A2 NZGB.indd 21/7/09 2:52:11 PM  
11  
OPTIMISING THE VENTSURFACE BY SELECTING COOKTOP TYPE  
To ensure best performance, the type of cooktop under the VentSurface needs to be selected after installing the appliance.  
To select the type of cooktop  
1
2
3
Make sure the VentSurface is on stand-by (plugged into a power outlet which is switched on but the fan is off).  
Press the  
and  
buttons simultaneously. A single horizontal segment will appear in the display.  
Release and re-press the buttons simultaneously again to scroll through the types of cooktops:  
Top segment – Gas  
Middle segment – Induction  
Bottom segment – Electric/Ceramic  
Gas  
Induction  
Electric  
Ceramic  
4
To store the type of cooktop last selected, press the  
or  
button.  
12  
SELECTING FILTER MODE  
After installation, the VentSurface has to be set to operate on aluminium mesh filter mode (if the extracted air is ducted outside) or carbon filter mode (if the extracted air is recirculated indoors).  
To change between filter modes  
1
2
Make sure the VentSurface is on stand-by (plugged into a power outlet which is switched on but the fan is off).  
Press the  
button.  
3a The display will show the “-“ symbol, indicating that the VentSurface is set to aluminium mesh filter mode (external ducting).  
OR  
3b The display will show the “C” symbol, indicating that the VentSurface is set to carbon filter mode (internal recirculation).  
4
Press the  
button and hold down for at least five seconds to change to the filter mode you want. The filter mode last selected will be activated.  
(2,2) -2- 599489D izona vsisland install A2 NZGB.indd 21/7/09 2:52:11 PM  
13  
FINAL CHECKLIST  
TO BE COMPLETED BY THE INSTALLER  
Have you used the correct fixing screws?  
Have you used the wall anchors provided?  
Have you used the washers provided?  
Have you made sure that all standard requirements for ducting/  
recirculation and electrical connection are met?  
Is the VentSurface set for the correct cooktop type and filter mode?  
Is there a means of disconnection from the mains electricity  
supply (disconnection switch or power outlet) accessible to the customer  
after installation?  
Have you removed the protective blue film from the stainless steel surfaces?  
Is the VentSurface earthed?  
OPERATION:  
Have you informed the customer about the cleaning alerts?  
Have you demonstrated the basic operation to the customer?  
Installer’s name:  
Installer’s signature:  
Installation company:  
Date of installation:  
LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER  

GE Monogram 164D3333P027 User Manual
FUNAI MJ419TG, MJ413TG User Manual
Elo TouchSystems ET1548L XXWC X User Manual
Eizo EIZO RadiForce GS220 User Manual
Dell UltraSharp 2407WFP User Manual
Cypress CY62128B User Manual
Conair Crib Toy BE52LED User Manual
Bose Lifestyle 235 User Manual
Asus P4B533 User Manual
Addonics Technologies ADSACFB User Manual