Installation instructions
IZONA CookSurface
CG903ML & CG903MLD models
NZ AU
Important!
SAVE THESE INSTRUCTIONS
The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please visit our
local website listed at the end of this document or contact your local Fisher & Paykel dealer.
1
SAFETY AND WARNINGS
Before you install the appliance, please make sure that
WARNING!
the local distribution conditions (nature of gas and pressure) and the adjustment of the appliance
are compatible. For adjustment conditions for this appliance, see ‘Gas rate summary’
a suitable disconnection switch is incorporated in the permanent wiring, mounted and positioned to
comply with the local wiring rules and regulations. A means of disconnection with at least a 3 mm
air gap contact separation in all poles must be incorporated into the ꢀxed wiring in accordance with
the wiring rules, unless the local wiring rules allow for alternative means
the appliance is connected to a 220V - 240V 50Hz (10 A) power supply only and earthed via the
power supply cable
Electrical shock hazard
Disconnect appliance from main power supply before continuing.
Failure to do so could result in electrical shock or death.
WARNING!
there is a power outlet within reach of the power supply cable (900 mm from the centre rear of the
product). This must be accessible after installation. The power supply cable should not touch any
metal parts
Cut hazard
if the power supply cable is damaged, it is replaced only by the special cable: Part no. 531953 - Flex
Terminal Block Assy NZ/AU, obtainable from authorised Fisher & Paykel Service Agents
the supply connection point (gas shut-oꢁ valve) is accessible after installation
the benchtop is made of a heat resistant material
Take care - panel edges are sharp.
Failure to use caution could result in injury or cuts.
the installation complies with all the requirements of Australian and New Zealand Gas Installation
Standards (AS5601, NZS5261), including that the product has to be installed so that the surface
temperature of any nearby combustible surface will not exceed 65 OC above ambient. See 3
‘Clearance Dimensions’.
Important safety precautions!
Particular attention shall be given to the relevant requirements regarding ventilation.
Please make this information available to the person installing the appliance as it could reduce your
installation costs.
When you install the appliance
This appliance is to be installed and connected to the electricity and gas supply only by an authorised
person.
Installation must comply with your local building and local gas authority codes and electricity
regulations.
Failure to install the appliance correctly could invalidate any warranty or liability claims.
These appliances are registered in: (New Zealand) at www.ess.govt.nz and (Australia) with SAI Global
This gas appliance is suitable for connection to natural gas only. If in doubt, refer to the local gas
network operator or gas supplier to conꢀrm gas type at installation site.
We do not recommend you ꢂush mount or seal this appliance into the bench with silicone or glue.
Doing so will make future servicing diꢃcult. Fisher & Paykel will not be liable for any costs associated
with removing or replacing a sealed-in appliance, nor for repairing any damage that may be incurred
by doing this.
Seal exposed bare edges of the cutout with an oil-based paint or moisture-proof polyurethane to
prevent possible moisture creeping between the cooktop trim and the benchtop.
We do not recommend the use of a down-draught extractor fan with the appliance, as it may distort
the ꢂame pattern, causing uneven heating and reduced cooking performance.
Where this appliance is installed in marine craft or in caravans, it shall not be used as a space heater.
No combustible material or products should be placed on this appliance at any time.
Do not spray aerosols in the vicinity of this appliance while it is in operation.
If, after following the instructions given, the appliance cannot be adjusted to perform correctly,
please refer to the Service & Warranty book for warranty details and your nearest Authorised Service
4
5
PARTS SUPPLIED
3
Wok stand (1)
Flexible
hose (1)
Blue washer (1)
Elbow
/
“ NPT (1)
Clamping
brackets (4)
and screws (4)
NG regulator (1)
Air intake
grill (1) and
screws (6)
8
GAS RATE SUMMARY
All appliances are factory set for natural gas and are not currently convertable to LPG.
NZ AU
SMALL
MEDIUM
WOK
NG (1.0 kPa)*
NG
NG
NG
CG903ML &
CG903MLD
1.09Y
7.2
1.15Y
8.0
1.65
12.8
*Nominal pressure with the two smaller burners on High.
6
FLUSH MOUNTING INSTALLATION (NOT RECOMMENDED)
view from below
A
C
E
B
WARNING!
B
x 4
C
A
D
We do not recommend ꢁush
mounting and sealing as servicing
requires the CookSurface to be
removed from the benchtop. The
owner carries all risk for ꢀush
mounting the CookSurface.
The owner must ensure the
F
G
E
M
CookSurface has been cut out
from the benchtop before
L
Reꢀt existing
screw to secure
into basepan
K
I
servicing can be carried out. Fisher
& Paykel will not be liable for any
costs associated with removing
or replacing a ꢁush-mounted
and/or sealed-in product, nor for
repairing any damage that may be
incurred by doing this.
2
1
20-50 mm
H
5 mm
Fresh air from
outside cabinetry
For benchtops thicker than
50 mm, reverse the clamping
brackets, as shown in 11
Top view
D
M
J
1
2
H
HI
II
I
Ensure silicone does
N
not leak underneath glass.
3
min. 150 OC rated
Product and cabinetry dimensions (mm)
Apply tape/foam
inside recess to stop
silicone leaking underneath.
overall height of product (including dials/pan supports)
96
96
900
530
94
A
B
C
D
E
F
G
H
HI
I
II
J
K
L
M
N
overall width of product
900
410
94
overall depth of product
F
height of chassis (below top of bench)
TO REMOVE PRODUCT
width of chassis
856
384
424
905
865
415
390
max. 10
64
856
480
480
905
865
535
494
depth of chassis
2
depth of chassis
tted elbow)
overall width of routered recess
width of cutout
overall depth of routered recess
depth of cutout
corner radius of cutout
max. 10
64
1
distance from top of bench to centre of gas inlet on product
distance from edge of chassis to gas inlet on product
corner radius of routered recess
20
20
max. 2
5
max. 2
5
height of routered recess
7
8
REMOVE FROM PACKAGING
ENSURE THERE IS ADEQUATE AIR SUPPLY
A
A
500 mm
50 mm
The CookSurface requires adequate air supply to fully function. The base of the CookSurface must have direct
unrestricted ventilation to the room where the CookSurface is installed. Do not ventilate the base area to an
external area that can be at diꢁerent air pressure to that of the burners. You may ventilate from adjacent
cupboards, but ensure that the available air supply will not be restricted. The ventilation area must be
500 x 50 mm or of an equivalent area. If the 50 mm wide slot is not possible due to the width of the available toe
recess, increase the length of the slot so as to maintain an equivalent area of 250 cm2. An air intake grill is provided.
Ensure that the grill is not covered or obstructed.
9
10
FIT THE ELBOW & FLEXIBLE HOSE
LOWER GENTLY INTO THE CUTOUT
A
A
Important!
The ꢀexible hose supplied
1
must be used to enable servicing.
2
” NPT
1
Ensure there is enough
ꢀexible hose looped to
allow for removing
2
PTFE
1
appliance for servicing.
11
12
SECURE THE PRODUCT TO THE BENCHTOP
CONNECT TO THE GAS & ELECTRICAL SUPPLY
A
view from below
B
A
NG
x 4
Ensure the blue washer is ꢂtted
½“ BSP
For benchtops thicker than 50 mm,
reverse the clamping brackets, as shown
Reꢂt existing
screw to secure
into basepan
Reꢂt existing
screw to secure
into basepan
NG
2
2
1
1
Fresh air from
outside cabinetry
Fresh air from
outside cabinetry
20-50 mm
50+mm
13
14
CHECK FOR GAS LEAKS
TEST OPERATION
A
A
Test operation by
lighting all burners.
1
2
3
4
GAS
GS
ON
15
FINAL CHECKLIST
Installer’s name:
TO BE COMPLETED BY THE INSTALLER
Have you installed the clamping brackets?
Installer’s signature:
Installation company:
Date of installation:
Have you allowed for adequate air supply to the product?
Have you used the supplied ꢁexible hose and blue washer?
Have you leak-tested all connections?
Is the regulator set to the correct working pressure?
Have you placed the supplied duplicate data plate on an adjacent surface?
Is the CookSurface earthed?
LEAVE THESE INSTRUCTIONS WITH THE CUSTOMER
Check that the power supply cable is NOT touching the CookSurface.
OPERATION:
Do all burners ignite both individually and in combination?
Are the ꢁames consistent and appropriately sized?
Have you demonstrated the basic operation to the customer?
|