Delta Tau MACRO CPU BOARD 4Ax 602804 xHxx User Manual

^1 HARDWARE REFERENCE MANUAL  
^2 MACRO CPU BOARD  
^3 HRM for UMAC MACRO & MACRO Stack  
^4 4Ax-602804-xHxx  
^5 January 29, 2003  
Single Source Machine Control  
Power // Flexibility // Ease of Use  
21314 Lassen Street Chatsworth, CA 91311 // Tel. (818) 998-2095 Fax. (818) 998-7807 // www.deltatau.com  
MACRO-CPU Hardware Reference  
CONTENTS  
Contents  
i
MACRO-CPU Hardware Reference  
INTRODUCTION  
The 3U MACRO-CPU board is the processor and MACRO interface board that is used in a 3U MACRO Station  
(in either UMAC MACRO or MACRO Stack configuration).  
Note  
There are 3 documents that describe the operation of Delta Tau Data Systems Inc. 3U MACRO  
Station products:  
UMAC System Manual (General Product Overview)  
3U MACRO Station User’s Manual  
3U MACRO Station Software Reference  
This manual describes the interfaces and physical hardware that is used on the  
3U MACRO CPU.  
The UMAC MACRO and the MACRO Stack provide a remote interface for encoders, flags, direct-PWM digital  
drives, analog drives, stepper drives, analog I/O, and digital I/O for Delta Tau Data's PMAC products that have a  
MACRO interface.  
The UMAC MACRO and MACRO Stack configurations communicate with PMAC2 Ultralites or Turbo PMAC2  
Ultralites solely through the MACRO ring, interfacing to standard drives, encoders, flags, and I/O through on-  
board connectors. This MACRO Station integrated packaging and connectivity strategy provides revolutionary  
flexibility and ease of use.  
A 3U MACRO Station consists of a set of “3U” format Euro-cards (100 x 160 mm) that can be assembled in a  
variety of configurations. When used in the rack configuration, connected through a backplane bus, the backplane  
is UBUS format, designed by Delta Tau Data Systems Inc. for motion control and I/O interfaces.  
When using the fiber optic MACRO interface, the 3U MACRO Station can be up to 3 kilometers (2 miles) away  
from the PMAC2 controller or any other station on the ring. When using the RJ-45 copper electrical interface, it  
can be up to 100 meters (~330 feet) away.  
The 3U MACRO Station allows PMAC2 MACRO controllers to control servo axes and I/O just as if they were  
directly connected to the PMAC2, even though they may be a great distance away. The only interface needed  
from the PMAC2 is the electrically isolated MACRO ring.  
Typically, a PMAC2 “Ultralite” board, one without any of its own servo interface circuitry, is used with the  
MACRO Station to provide the most cost-effective solution.  
Introduction  
1
 
MACRO-CPU Hardware Reference  
3U MACRO-CPU Board (3A0-602804-10x):  
80MHz DSP56303 CPU  
512k x 8 flash memory for user backup & firmware  
Latest released firmware version  
RS-232 serial interface for setup and debugging  
Stack connectors for servo and I/O accessory boards  
UBUS connector for backplane connection to servo  
and I/O accessory boards  
JTHW multiplexed I/O port with 26-pin IDC header  
The 3U MACRO Station can be configured in either of two fundamental assemblies – “UMAC MACRO” and  
“MACRO Stack”:  
UMAC MACRO – In this configuration (once called  
"Pack") the 3U-format boards are put together to  
communicate through a backplane bus called the UBUS.  
All boards are installed in a Euro-card rack. In this  
configuration, all 3U-format boards or modules can be  
installed or withdrawn from the pack individually,  
providing ease of installation, debugging, and repair.  
The photo at the upper right shows a UMAC rack with power  
supply and I/O boards that are connected through a backplane.  
This system allows for an easier integration of the 3U  
MACRO-CPU for larger (up to 8 axes) applications.  
UMAC MACRO Station  
Configuration  
MACRO Stack – In the Stack configuration the 3U-format  
boards are put together as a stack of piggyback boards,  
(right, below). This configuration is ideal for compact,  
cost-sensitive embedded applications.  
4 Axis Stack Configuration  
Note:  
The Stack boards and related breakout boards can be installed in a Euro-card rack,  
creating a hybrid “stack/pack” configuration. This requires a special backplane  
configuration that makes removing stack boards difficult.  
This hybrid configuration is now recommended for existing “legacy” systems only.  
3U Product Configurations (General Description)  
2
Introduction  
 
MACRO-CPU Hardware Reference  
Assemblies of 3U-format boards can be made with either of two CPU processor boards – a 3U MACRO-CPU  
board, or a 3U Turbo PMAC2 CPU board. Most other 3U-format boards, labeled “Accessory” boards, can be  
used with either CPU board.  
When the 3U MACRO-CPU board is used, the resulting assemblies are called “UMAC MACRO” or "3U  
MACRO Stack."  
When the 3U Turbo PMAC2 CPU board is used, the resulting assemblies are called “UMAC Turbo” or  
"Turbo Stack."  
Refer to the "UMAC & 3U Stack Products Selection Guide" for more detailed descriptions of how the rack and  
stack products are integrated.  
UMAC and 3U-Stack Products  
UMAC Products  
Stack Products  
UMAC Turbo  
UMAC MACRO  
Turbo Stack  
MACRO Stack  
The UMAC Turbo is composed of  
a 3U-format Turbo PMAC2 CPU  
board and a set of accessory boards  
in 3U-format, all plugged in a  
common UBUS backplane and  
installed inside a 3U format rack. A  
PC/104 computer and several  
The UMAC MACRO is composed  
of a MACRO Interface/CPU board  
and a set of accessory boards in 3U-  
format, all plugged in a common  
UBUS backplane and installed  
insidea 3U format rack. The UMAC  
MACRO must receive commands  
The Turbo stack is composed of a  
3U-format Turbo PMAC2 CPU  
board and a set of accessory boards  
in 3U-format plugged to it in a stack  
configuration. The Turbo stack  
configuration is less expensive than  
the UMAC Turbo system but it is  
limited to eight axes of motion  
control versus 32 axes on a UMAC  
Turbo system. The Turbo Stack is  
The MACRO stack is composed of  
a MACRO Interface/CPU board  
and a set of accessory boards in  
3U-format plugged to it in a stack  
configuration.  
The  
UMAC  
MACRO must receive commands  
from an external MACRO  
compatible device like a PMAC2  
optional  
communication  
from  
an  
external MACRO  
accessories (including all of the  
major FieldBuses, MACRO and  
Ethernet) can be installedinside the  
compatible device like a PMAC2  
Ultralite or a UMAC Turbo system.  
The UMAC MACRO does not  
support a PC/104 or communication  
accessories and it is preferred for  
distributed control over a MACRO  
ring connection.  
Ultralite or  
a
UMAC Turbo  
system. The MACRO Stack is  
selected over a UMAC MACRO  
system becauseit is more compact,  
allowing its installation inside  
already existingcabinets with some  
space limitations.  
selected over  
a
UMAC Turbo  
UMAC  
system  
providing  
system because is more compact,  
allowing its installation inside  
already existing cabinets with some  
space limitations.  
convenient flexibility and virtually  
unlimited expandability.  
Introduction  
3
MACRO-CPU Hardware Reference  
MACRO CPU Specifications  
Physical Specifications  
Size:  
33.5cm x 9.9cm x 3.8cm (13.2" x 3.9" x 1.4")  
½ lb.  
Weight:  
Temperature  
Operating: 0°C to 60°C (32°)F to 140°F)  
Storage:  
Humidity:  
12°C to 82°C (10°F to 180°F)  
10% to 95%, noncondensing  
Electrical Specifications  
Power:  
1.5A @ +5V (±5%) (7.5W) Pertains to 8-channel configuration, with a typical load of  
encoders.  
4
Introduction  
 
MACRO-CPU Hardware Reference  
3U MACRO-CPU CONFIGURATION  
The purchase of the 3U MACRO CPU board provides a 3U-format (100mm x 160mm) board with a DSP  
processor, MACRO ring circuitry, “piggyback” connectors onto which “stack” accessory boards can be mounted,  
and a backplane connector through which other 3U-format boards can be connected by means of a “UBUS”  
passive-backplane board.  
The MACRO CPU board went through an extensive redesign in the –105 revision, because key components on  
the –104 and older revisions became obsolete. Both the older and the newer versions are described in this  
manual. The only system change required is a slight change in the DIP-switch addressing of ACC-24E2x and  
ACC-51E backplane axis boards when using the new MACRO CPU boards.  
Note  
It is recommended that only the new MACRO CPU boards, which have stronger backplane bus  
drivers, be used in “UMAC” pack configurations.)  
The 3U MACRO-CPU can be purchased in two physical configurations, distinguished by part number prefix:  
300-602804-10x provides the 3U MACRO-CPU board without a front plate. This configuration is  
recommended for “stack” assemblies.  
3R0-602804-10x provides the 3U MACRO-CPU board with a front plate. This configuration is  
recommended for “UMAC” rack assemblies. The top and bottom plates are provided with the ACC-Px  
rack.  
There are a few options available for the MACRO CPU board.  
One of the Options A or C must be present on a MACRO CPU board to provide the actual MACRO ring interface  
circuitry; both may be present:  
Option A provides an SC-style fiber-optic transceiver to connect into the MACRO ring. Its main component is  
the U73 transceiver.  
Option C provides RJ-45 electrical input and output connectors for the MACRO ring. Its main components are  
J14 and J17.  
Option 10 permits a specified revision of the MACRO Station firmware to be installed in the flash memory in the  
card. Without this option, the latest released revision is installed. A label on the flash memory IC indicates the  
firmware revision installed at the factory (but not necessarily which revision is presently installed in the IC). The  
presently installed revision can be ascertained by using the MSVER{node #}command.  
3U MACRO-CPU Configuration  
5
 
MACRO-CPU Hardware Reference  
6
3U MACRO-CPU Configuration  
MACRO-CPU Hardware Reference  
3U MACRO CPU BOARD HARDWARE SETUP  
The hardware setup of the 3U MACRO CPU Board consists of the setting of 2 rotary switches, the setting of  
several E-point jumpers on each board, followed by power supply and signal connections.  
Note  
E-Point Jumper numbers are shown in white ink on the legend of each board. Pin numbers for  
each number can be determined either from the legend on the component side on the board, or by  
looking at the solder side of the board, where pin 1 has a square solder pad.  
3U MACRO CPU Board Jumper & Switch Setup  
The MACRO Station has two 16-way rotary switches on the MACRO CPU board that establish the station’s basic  
configuration on the MACRO ring.  
SW1 Rotary Switch Setting: SW1 establishes how many servo nodes, and which servo nodes, will be used on  
the MACRO station. It also establishes the mapping of MACRO node numbers to MACRO Station channel  
numbers. This mapping information will be important in establishing the software setup.  
The following table shows possible MACRO Station axis configurations and the appropriate settings of SW1:  
# of  
Servo  
Which  
MACR  
Stack Axis  
Boards Used  
Backplane (UMAC) Axis  
Boards Used  
SW1 Setting  
Chan’s O Servo  
&
Nodes  
Nodes  
Used  
Used  
2
2
2
2
2
2
2
2
4
0, 1  
4, 5  
8, 9  
12, 13  
0, 1  
4, 5  
8, 9  
12, 13  
0, 1, 4, 5  
1x ACC-1E  
1x ACC-1E  
1x ACC-1E  
1x ACC-1E  
1x ACC-2E*  
1x ACC-2E*  
1x ACC-2E*  
1x ACC-2E*  
1x ACC-2E  
--  
--  
--  
--  
8
9
10 ($A)  
11 ($B)  
1x ACC-24E2x or 51E  
1x ACC-24E2x or 51E  
1x ACC-24E2x or 51E  
1x ACC-24E2x or 51E  
1x ACC-24E2x w/ Opt 1x or 1x  
ACC-51E w/ Opt 1  
1x ACC-24E2x w/ Opt 1x or 1x  
ACC-51E w/ Opt 1  
1x ACC-24E2x w/ Opt 1x or 1x  
ACC-51E w/ Opt 1;  
plus 1x ACC-24E2x or 51E  
1x ACC-24E2x w/ Opt 1x or 1x  
ACC-51E w/ Opt 1;  
plus 1x ACC-24E2x or 51E  
2x ACC-24E2x w/ Opt 1x /  
ACC-51E w/ Opt 1  
2
3
4
5
0
4
6
8, 9, 12,  
13  
0, 1, 4, 5,  
8, 9  
1x ACC-2E  
1
1x ACC-1E,  
1x ACC-2E  
12 ($C)  
6
8
0, 1, 4, 5,  
8, 9  
2x ACC-2E*  
2x ACC-2E  
6
7
0, 1, 4, 5,  
8, 9, 12,  
13  
More detailed information on the SW1 settings is presented in the Jumper/Switch description in the back of this  
manual.  
3U MACRO CPU Board Hardware Setup  
7
 
MACRO-CPU Hardware Reference  
SW2 Rotary Switch Setting: SW2 establishes the number of the master IC to which the MACRO station will  
respond. The values of 0 to 15 correspond to Master numbers 0 to 15, respectively. For a non-Turbo PMAC2  
master, this value must match the master number value in the first hexadecimal digit of PMAC2’s I996. For a  
Turbo PMAC2, this value must match the master number value in the first hexadecimal digit of the Turbo  
PMAC2’s I6840, I6890, I6940, or I6990, for MACRO ICs 0, 1, 2, or 3, respectively, on the Turbo PMAC2. The  
default switch setting is 0, so the station will respond to Master 0.  
Watchdog Timer Enable Jumper: For normal operation of the Compact MACRO Station, jumper E1 should be  
OFF to enable the watchdog timer (an important safety feature).  
Operational Mode Jumper: Jumper E2 should connect pins 2 and 3 to tell the CPU it is in normal operational  
mode, not in “bootstrap” mode. It should only connect pins 1 and 2 if you desire to load new firmware into the  
flash IC through the serial port.  
Baud Rate Jumper: Jumper E3 must be ON if you are connecting an ACC-8D Option 9 Yaskawa absolute  
encoder converter to the J7 serial port (most users will connect it to the JTHW port instead). This sets the baud  
rate to 9600. If E3 is OFF, the baud rate is 38400.  
Power Supply Check Jumper: Remove jumper E4 if you are not bringing a +/-12V to +/-15V supply into the  
Compact MACRO Station itself (5V only). If you are bringing these analog circuit supplies into the Compact  
MACRO Station, it is best to have jumper E4 on, so that the servo outputs are disabled if either of the analog  
supplies is lost.  
MACRO Input Select Jumper: Because the MACRO CPU board can potentially accept MACRO ring input  
from either the RJ-45 electrical input or the fiber input, you must select which input is used (even if only one of  
the ring interface options is present). Jumper E40 must be ON to use the fiber input; it must be OFF to use the  
electrical input. (If both interface options A and C are present, either ring output may be used, regardless of the  
setting of E40.)  
MACRO Signal-Loss Detect Jumper: Jumper E5 (board revisions –105 and newer only) should connect pins 1  
and 2 so that the MACRO receiver’s (fiber or electrical) loss-of-signal detect is reported automatically as a byte  
“violation” error. Older revisions (-104 and before) of the board could not use the receiver’s signal-loss detect as  
a “violation” error (relying on higher-level detection schemes), and connecting pins 2 and 3 makes operation of  
the new revision completely compatible with the old. This is not recommended.  
MACRO CPU Board Connections  
The connection of Compact MACRO Station to other stations on the MACRO ring is achieved by connecting the  
output connector of the Compact MACRO Station to the input connector of the next station, and by connecting  
the output connector of the previous station to the input connector of the Compact MACRO Station. There must  
be a completely connected ring, with all stations powered up, for any communications to occur on the ring.  
Optical Fiber Ring Connection: The U73 integrated fiber optic transceiver is used for both the optical fiber  
input and the optical fiber output connections to the MACRO ring. With the component side of the board up, and  
the opening facing you, the input socket is on the right, and the output socket is on the left (these are marked on  
the component).  
RJ45 Electrical Ring Connection: The J14 connector is used for the input from the previous station on the  
MACRO ring if electrical connection is used, and the J17 connector is used for the output to the next station on  
the MACRO ring.  
Multiplexer Port: The J6 26-pin header is used to connect to multiplexer port accessories such as the ACC-8D  
Opt 7 resolver-to-digital converter board and the ACC-8D Opt. 9 Yaskawa absolute encoder interface board. This  
port can be used alternately to provide 8 inputs and 8 outputs (non-multiplexed) at TTL levels.  
Backplane “UBUS” Expansion Port: The P2 96-pin DIN header is used to connect to expansion port  
accessories such as the ACC-9E, 10E, 11E, 12E, and 14E I/O boards, or the ACC-24E2x axis boards, through an  
8
3U MACRO CPU Board Hardware Setup  
 
MACRO-CPU Hardware Reference  
ACC-Ux “UBUS” backplane board. It can also be used to bring in 5V power, and optionally +/-15V power, from  
a backplane or breakout board, to the entire MACRO Station.  
Note  
When interfacing to accessory boards across the UBUS backplane, it is strongly recommended to  
use a new revision (-105 or higher) of the MACRO CPU board, and an ACC-Ux backplane board  
(not an older ACC-Jx backplane board). The newer revision MACRO CPU boards have stronger  
bus driver ICs, but they do not work well with the termination of the ACC-Jx backplane boards.  
Power Terminal Block: The TB1 4-point terminal block can be used to bring in 5V power, and optionally  
+/-15V power, to the entire MACRO Station. In a UMAC (pack) configuration, the power is more likely to be  
brought in through the backplane.  
3U MACRO CPU Board Hardware Setup  
9
MACRO-CPU Hardware Reference  
10  
3U MACRO CPU Board Hardware Setup  
MACRO-CPU Hardware Reference  
3U MACRO-CPU JUMPER AND SWITCH CONFIGURATIONS  
3U MACRO-CPU Card Layout  
The "Location" columns of the following tables refer to the mapped locatiEons shown in the drawings below:  
C D F  
B
A
1
2
3
4
REV-105 and Later Revisions  
REV-104 and Earlier Revisions  
Note:  
Pin 1 of an E-point is masked by an "X" in white ink on the composite side, and by a square  
solder pad on the solder side.  
3U MACRO-CPU Jumper and Switch Configurations  
11  
 
MACRO-CPU Hardware Reference  
E1: Watchdog Timer Disable  
Rev -105  
and Later  
Location  
Rev -104  
and Earlier  
Location  
Jumper  
Type  
Description  
Default  
Remove jumper to enable Watchdog Timer.  
not jumpered  
2-PIN  
B-1  
F-1  
Jump pins 1 and 2 to disable Watchdog Timer (for test  
purposes only)  
E2: CPU Mode Operation  
Rev -105  
and Later  
Location  
Rev -104  
and Earlier  
Location  
Jumper  
Type  
Description  
Default  
Jump pins 1 and 2 for firmware download through serial  
port.  
Pin 2-3  
3-PIN  
D-2  
D-1  
Jump pins 2 and 3 for normal operation.  
E3: Serial Port Baud Rate  
Rev -105  
and Later  
Location  
Rev -104  
and Earlier  
Location  
Jumper  
Type  
Description  
Default  
Jump pins 1 and 2 for 9600-baud serial port operation.  
(Required for Yaskawa interface).  
not jumpered  
2-PIN  
E-3  
E-2  
Remove jumper for 38400-baud serial port operation.  
E4: Power Supply-Loss Control (±15Vdc Supply Monitor)  
Rev -105  
and Later  
Location  
Rev -104  
and Earlier  
Location  
Jumper  
Type  
Description  
Default  
Jump pins 1 and 2 to disable servo outputs on loss of +5V,  
+15V, or –15V power supply.  
not jumpered  
2-PIN  
E-3  
E-2  
Remove this jumper to monitor +5Vdc power supply only.  
±15V supply monitoring is not usually required for  
applications without DACs or A-D converters.  
12  
3U MACRO-CPU Jumper and Switch Configurations  
 
MACRO-CPU Hardware Reference  
E5: MACRO Received Signal Detect/Bypass Mode (rev -105 and 106 only). Does  
not exist on rev 107 and later models.  
Rev -105  
and Later and Earlier  
Rev -104  
Jumper  
Type  
Description  
Default  
Location  
B-3  
Location  
Jump pins 1 and 2 to access the receiver’s signal detect operation.  
Pin 1-2  
Jump pins 2 and 3 to bypass the receiver’s signal detect  
operation.  
3-PIN  
This jumper does not exist on MACRO-CPU versions -104  
and earlier.  
E40: MACRO Input (Fiber/Wired) Selector  
Rev -105  
and Later and Earlier  
Rev -104  
Jumper  
Type  
Description  
Default  
Location  
B-3  
Location  
Remove jumper to select MACRO wired (RJ45) input from J14.  
Jump pins 1 and 2 to select MACRO fiber optic input from U73.  
Jumpered  
(Option A)  
2-PIN  
C-3  
Not  
jumpered  
(Option C)  
JP3: MACRO Loop back Test Select For Copper Only (rev -104 and earlier)  
Rev -105  
and Later and Earlier  
Rev -104  
Jumper  
Type  
Description  
Default  
Location  
Location  
B-1  
Remove jumper to select loop back in the copper interface of  
MACRO communications (for test purposes only).  
jumpered  
Jump pins 1 and 2 for normal copper MACRO communications.  
2-PIN  
This jumper does not exist on MACRO-CPU versions -105  
and greater.  
JP4: Reserved for Future Use  
3U MACRO-CPU Jumper and Switch Configurations  
13  
 
MACRO-CPU Hardware Reference  
JP5-JP6: MACRO Copper EQ Select (rev -104 and earlier)  
Rev -105  
and Later and Earlier  
Rev -104  
Jumper  
Type  
Description  
Default  
Location  
Location  
B-1  
not jumpered  
These jumpers are used to select different modes of  
equalization when copper-based communications are used.  
When not jumpered, adaptive equalization is used. JP5 and  
JP6 are used for manufacturer's testing only.  
2-PIN  
These jumpers do not exist on MACRO-CPU versions -105  
and greater.  
14  
3U MACRO-CPU Jumper and Switch Configurations  
 
MACRO-CPU Hardware Reference  
Switch Configurations  
SW1: MACRO Slave Node Configure  
SW1  
Setting  
# of Servo MACRO  
Station  
Channel  
Nos.  
Station  
Channel  
Starting  
Addresses  
1st Axis 2nd Axis PMAC2's I996  
PMAC2's I1000,  
I1002 Value  
(Turbo  
PMAC2’s I70,  
I71, etc.)  
Channels  
& Nodes  
Used  
Servo  
Nodes  
Specified  
Board  
Servo  
IC  
Board  
Servo  
IC  
Value **  
(Turbo  
PMAC2’S  
I6840, etc.  
$F8033  
0
(default)  
1
4
4
0, 1, 4, 5  
1, 2, 3, 4 $C000, $C008,  
$C010, $C018*  
1, 2, 3, 4 $C000, $C008,  
$C010, $C018*  
4-axis  
4-axis  
None  
None  
$0033  
8, 9, 12,  
13  
$FB300  
$3300  
2
3
4
5
6
2
2
2
2
6
0, 1  
4, 5  
8, 9  
12, 13  
0, 1, 4, 5,  
8, 9  
1, 2  
3, 4  
1, 2  
3, 4  
$C000, $C008*  
$C010, $C018*  
$C000, $C008*  
$C010, $C018*  
4-axis  
4-axis  
4-axis  
4-axis  
4-axis  
None  
None  
None  
None  
4-axis  
$F8003  
$F8030  
$F8300  
$FB000  
$F8333  
$0003  
$0030  
$0300  
$3000  
$0333  
1, 2, 3, 4, $C000, $C008,  
5, 6  
$C010, $C018,  
$C020, $C028*  
7
8
0, 1, 4, 5,  
8, 9, 12,  
13  
1, 2, 3, 4, $C000, $C008,  
5, 6, 7, 8 $C010, $C018,  
$C020, $C028,  
4-axis  
4-axis  
$FB333  
$3333  
$C030, $C038*  
8
9
10  
11  
12  
2
2
2
2
6
0, 1  
4, 5  
8, 9  
12. 13  
0, 1, 4, 5,  
8, 9  
9, 10  
9, 10  
9, 10  
9, 10  
$C090, $C098  
$C090, $C098  
$C090, $C098  
$C090, $C098  
2-axis  
2-axis  
2-axis  
2-axis  
4-axis  
None  
None  
None  
None  
2-axis  
$F8003  
$F8030  
$F8300  
$FB000  
$FB333  
$0003  
$0030  
$0300  
$3000  
$0333  
1, 2, 3, 4, $C000, $C008.  
9, 10  
$C010, $C018,*  
$C090, $C098  
None  
13  
0
None  
None  
None  
-
None  
-
$F8000  
$F8800  
$0000  
(I/O only)  
(Reserved For  
0
14  
15  
Future  
-
Use)  
-
11  
-
***  
*
These addresses are for stack axis boards. Add $40 to these addresses for backplane axis boards.  
** Other bits of this I-variable may also be set to enable I/O nodes or other slave stations it is commanding  
*** A setting of 15 forces the station to use its factory default I-variables on power-up/reset.  
SW2: MACRO Master Number Select  
0: Commanded from Master IC # 0  
1: Commanded from Master IC # 1  
F: Commanded from Master IC # F (15)  
3U MACRO-CPU Jumper and Switch Configurations  
15  
 
MACRO-CPU Hardware Reference  
Connector Summary  
J1: ☼  
J2: ☼  
J3: ☼  
J4: ☼  
J5: ☼  
J6:  
JEXP_A: for interboard connection  
JEXP_B: for interboard connection  
JEXP_C: for interboard connection  
JISP: Factory configuration header  
JTAG/OnCE: Factory troubleshoot header  
JTHW: Multiplexer Port Connector  
JRS232: Serial Port Connector  
J7:  
J14, J17:  
P1:  
RJ45: MACRO Copper I/O (OPT C)  
JEXP: Backplane Expansion Port Connector  
JPWR: 4-Pin Terminal Block  
TB1:  
U73:  
MACRO Fiber Optic Connector (OPT A)  
These connectors are not typically designated as end-user interfaces. The pinouts are not included in this hardware  
reference manual. Consult the factory if pinout information is needed.  
16  
3U MACRO-CPU Jumper and Switch Configurations  
 
MACRO-CPU Hardware Reference  
MACRO STATION CHARACTER DISPLAY  
The Compact MACRO Station has a single hexadecimal character display on the CPU/Interface Board that  
provides useful information as to the status of the station. The display can show the following values:  
Value  
(Blank)  
Meaning  
Ring not active  
0-8  
9
Operation OK; value is # of motors enabled  
(reserved for future use)  
Amplifier fault  
Ring break fault  
CPU failure fault  
Ring data error  
Loss-of-encoder fault  
Other failure  
A
B
C
D
E
F
MACRO Station Character Display  
17  
 
MACRO-CPU Hardware Reference  
HARDWARE RE-INITIALIZATION  
MACRO hardware reinitialization to factory defaults is enabled when the SW1 setting is set to 15 or F  
(hexidecimal) and the power is cycled at the MACRO Station. The only time the user would want to use a  
hardware reinitialization to factory defaults with the MACRO Station would be if the MACRO Station always  
powers up with a watchdog (typically if the ring clock at the Ultralite is different than the ring clock at the  
MACRO Station). Node 11 will be the only MACRO Station node enabled. Therefore the user will have to enable  
node 11 of the MACRO IC at the Ultralite to communicate to the MACRO Station.  
Ultralite Example: Servo nodes 0,1,4,5 enabled at Ultralite (I996=$0F8033)  
(A) The user would have to enable node 11, I996=$0F8833  
(B) Then user can reistablish communications with MS11,(MIvar) commands  
(C) Issue MS$$$***11 to ensure re-initialization  
(D) Issue MSSAVE11 command to save the factory defaults to the Station  
Turbo Ultralite Example: Servo nodes 0,1,4,5 enabled at Ultralite (I6841=$0F8033)  
(A) The user would have to enable node 11, I996=$0F8833  
(B) Then user can reistablish communications with MS11,(MIvar) commands  
(C) Issue MS$$$***11 to ensure re-initialization  
(D) Issue MSSAVE11 command to save the factory defaults to the Station  
18  
Hardware Re-initialization  
 
MACRO-CPU Hardware Reference  
Hardware Re-initialization  
19  
MACRO-CPU Hardware Reference  
FIRMWARE UPDATES  
Downloading new firmware to the MACRO Station is a simple process once the MACRO board is setup properly.  
To download new firmware to the MACRO station, the user must have the following items:  
5V power supply  
2 jumpers  
DB9 female to 10 pin header (any cable used for PMAC RS232 communications)  
PC at the DOS prompt.  
New firmware and necessary downloading batch files  
Make sure to power down the MACRO Station  
To download the software to the MACRO station, the user will first jumper the following E2 (1-2) and E1 (1-2).  
Wire the 5V power to the appropriate terminal on the MACRO station or plug into 3U Rack.  
Place the 10 pin header cable to the serial connection on the MACRO-station and place the other end to the  
COM1 port on the PC (the batch files were written for COM1 but could be modified if necessary).  
Goto the DOS prompt and create a directory called firmware and station (as an example).  
C:\firmware\station  
a:\copy *.* c:\firmware\station  
Go back to the c drive and type the following command  
c:\firmware\station\mcdwnld  
The firmware will be down loaded to the MACRO station. Easy!  
The PMAC Executive Software will soon have the capability of downloading the MACRO Station firmware in  
the Windows Operating Environment.  
(5) Place jumper E2 back to pins 2-3 and remove E1 jumper  
Please call the factory if you have any questions.  
20  
Firmware Updates  
 
MACRO-CPU Hardware Reference  
Firmware Updates  
21  
MACRO-CPU Hardware Reference  
3U MACRO-CPU BOARD CONNECTOR PIN-OUTS  
The schematic circuits shown in this section are for interface reference only. Subtle differences may exist  
between the circuits shown here and the actual hardware used.  
J6: (JTHW) Multiplexer Port Connector  
(26-pin Header at Location D-3)  
Front View  
Notes  
Pin #  
Symbol  
Function  
Description  
PMAC Common  
1
2
3
4
5
6
7
8
GND  
GND  
DAT0  
SEL0  
DAT1  
SEL1  
DAT2  
SEL2  
DAT3  
SEL3  
DAT4  
SEL4  
DAT5  
SEL5  
DAT6  
SEL6  
DAT7  
SEL7  
N.C.  
Common  
Common  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
In/Out  
N.C  
PMAC Common  
Data Byte Bit 0  
Select Byte Bit 0  
Data Byte Bit 1  
Select Byte Bit 1  
Data Byte Bit 2  
Select Byte Bit 2  
Data Byte Bit 3  
Select Byte Bit 3  
Data Byte Bit 4  
Select Byte Bit 4  
Data Byte Bit 5  
Select Byte Bit 5  
Data Byte Bit 6  
Select Byte Bit 6  
Data Byte Bit 7  
Select Byte Bit 7  
No Connection  
PMAC Common  
Buffer Request  
PMAC Common  
In Position  
Must be IN for MUX  
Must be OUT for MUX  
Must be IN for MUX  
Must be OUT for MUX  
Must be IN for MUX  
Must be OUT for MUX  
Must be IN for MUX  
Must be OUT for MUX  
Must be IN for MUX  
Must be OUT for MUX  
Must be IN for MUX  
Must be OUT for MUX  
Must be IN for MUX  
Must be OUT for MUX  
Must be IN for MUX  
Must be OUT for MUX  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
GND  
BRLD/  
GND  
IPLD/  
GND  
+5V  
Common  
Output  
Common  
Output  
Common  
Output  
Input  
Low is “BUFFER REQ.”  
Low is “IN POSITION”  
PMAC Common  
+5VDC Supply  
PMAC RESET  
Power Supply OUT  
Low is “RESET”  
INIT/  
22  
3U MACRO-CPU Board Connector Pin-outs  
 
MACRO-CPU Hardware Reference  
U12  
160  
159  
158  
157  
156  
155  
154  
153  
152  
151  
150  
149  
148  
147  
146  
145  
144  
143  
142  
141  
140  
139  
138  
137  
136  
135  
134  
133  
132  
131  
130  
129  
128  
127  
126  
125  
124  
123  
122  
121  
120  
119  
118  
117  
116  
115  
114  
113  
112  
111  
110  
109  
108  
107  
106  
105  
104  
103  
102  
101  
100  
99  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
VDD  
VDD2  
IO_00 FLAG_W1  
IO_01 FLAG_V1  
IO_02 FLAG_U1  
IO_03 FLAG_T1  
IO_04 FLAG_D1  
IO_05 FLAG_C1  
IO_06 FLAG_B1  
IO_07 FLAG_A1  
DATA_0 ENC_C1  
ENC_B1  
VSS  
FAULT_1 DATA_2  
FAULT_2 DATA_3  
EQU_1 DATA_4  
EQU_2 DATA_5  
AENA_1 DATA_6  
AENA_2 DATA_7  
A0  
A1  
A2  
A3  
A4  
ENC_A1  
VSS  
A5  
A6  
RD  
WR  
PUL_1 PWM_C_B1  
DIR_1 PWM_C_T1  
IO_08 PWM_B_B1  
IO_09 PWM_B_T1  
IO_10 PWM_A_B1  
IO_11 PWM_A_T1  
VSS2  
CS  
ADC_STRB SEL_0  
VSS2  
ADC_CLK SEL_1  
ADC_1 SEL_2  
ADC_2 SEL_3  
ADC_3 SEL_4  
ADC_4 SEL_5  
S_CLK SEL_6  
S_CLKDIR SEL_7  
SERVO  
PHASE  
DIN0  
DIN1  
DIN2  
DIN3  
DIN4  
DIN5  
DIN6  
DIN7  
DATA_STRB  
VSS2  
VDD2  
VDD  
CMD_IN  
CMD_OUT  
CMD_STROBE  
DOUT0  
DOUT1  
DOUT2  
DOUT3  
DOUT4  
DOUT5  
DOUT6  
DOUT7  
VSS2  
VLTN  
STROBE_OUT  
TCLK  
CTRL0  
CTRL1  
CTRL2  
VSS  
VDD2  
CTRL3  
DISP0  
DISP1  
DISP2  
DISP3  
VDD  
IO_12 PWM_A_T2  
IO_13 PWM_A_B2  
IO_14 PWM_B_T2  
IO_15 PWM_B_B2  
DIR_2 PWM_C_T2  
PUL_2 PWM_C_B2  
VSS2  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
ENC_A2  
ENC_B2  
DATA_1 ENC_C2  
IO_16 FLAG_A2  
IO_17 FLAG_B2  
IO_18 FLAG_C2  
IO_19 FLAG_D2  
IO_20 FLAG_T2  
IO_21 FLAG_U2  
IO_22 FLAG_V2  
IO_23 FLAG_W2  
VDD  
VDD2  
VSS2  
DB0  
DB1  
DB2  
DB3  
DB4  
DB5  
DB6  
DB7  
DB8  
DB9  
DB10  
DB11  
TEST1  
TEST_CLK  
VDD2  
PLLVDD  
CLK20MHZ  
PLLVSS  
LP1  
LP2  
PLLAGND  
VSS2  
RESET  
TESTOUT  
DB12  
DB13  
DB14  
DB15  
DB16  
DB17  
DB18  
+5V  
RP6  
RP7  
3.3KSIP10C  
3.3KSIP10C  
J6  
(JTHW)  
J6  
U98  
48  
47  
46  
45  
1
2
3
4
5
6
7
8
TI00  
OE1  
A0  
A1  
GND  
A2  
A3  
VCC  
A4  
A5  
GND  
A6  
T/R1  
B0  
B1  
GND  
B2  
B3  
VCC  
B4  
B5  
GND  
B6  
B7  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
98  
97  
96  
95  
94  
93  
92  
91  
90  
89  
88  
87  
86  
85  
84  
83  
DAT0  
DAT1  
DISP0  
DISP1  
DISP2  
DISP3  
DISP4  
DISP5  
DISP6  
DISP7  
DAT0  
SEL0  
DAT1  
SEL1  
DAT2  
SEL2  
DAT3  
SEL3  
DAT4  
SEL4  
DAT5  
SEL5  
DAT6  
SEL6  
DAT7  
SEL7  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
DAT2  
DAT3  
DISP4  
VSS  
DISP5  
DISP6  
DISP7  
IO_24  
IO_25  
IO_26  
IO_27  
IO_28  
IO_29  
IO_30  
IO_31  
VDD2  
+5V  
+5V  
DAT4  
DAT5  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
DAT6  
DAT7  
SEL0  
SEL1  
IO_24  
IO_25  
IO_26  
IO_27  
IO_28  
IO_29  
IO_30  
IO_31  
A7  
A8  
A9  
DB19  
DB20  
DB21  
DB22  
DB23  
VSS  
VDD  
B8  
B9  
GND  
A10  
A11  
VCC  
A12  
A13  
GND  
A14  
A15  
OE2  
GND  
B10  
B11  
VCC  
B12  
B13  
GND  
B14  
B15  
T/R2  
SEL2  
SEL3  
82  
81  
SEL4  
SEL5  
DSPGATE2A  
(TQFP160)  
SEL6  
SEL7  
TI01  
+5V  
INIT-  
74FCT16245  
(TSSOP)  
GND  
GND  
HEADER 26  
GND  
Circuitry For J6- JTHW Interface  
3U MACRO-CPU Board Connector Pin-outs  
23  
MACRO-CPU Hardware Reference  
J7: (JRS232) Serial Port Connector  
(10-pin Header at Location C-1)  
Front View  
Notes  
Pin #  
Symbol  
N.C.  
Function  
Description  
No connection  
1
2
3
DTR  
TXD/  
CTS  
BIDIRECT  
OUTPUT  
INPUT  
Data Terminal Ready  
Send Data  
Clear to Send  
Just tied to “DSR”  
Transmit data to host  
Host Ready bit  
4
5
6
7
8
9
10  
RXD/  
RTS  
DSR  
N.C.  
GND  
+5V  
INPUT  
Receive Data  
Receive data from host  
PMAC Ready bit  
Just tied to “DTR”  
OUTPUT  
BIDIRECT  
OUTPUT  
COMMON  
OUTPUT  
Request to Send  
Data Set Ready  
No Connection  
PMAC Common  
+5VDC Supply  
Power supply out  
+5V  
C18  
.1UF  
C17  
U5  
C14  
J7  
6
4
2
.1UF  
C16  
.1UF  
C15  
V-  
+V  
C1+  
C1-  
(JRS232)  
1
C2+  
C2-  
J7  
5
3
.1UF  
.1UF  
TXD  
RXD  
N.C.  
DTR  
1
2
TXD-  
CTS  
RXD-  
RTS  
14  
13  
7
11  
12  
10  
9
TXD-  
CTS  
RXD-  
RTS  
DSR  
N.C.  
GND  
3
4
5
6
7
8
9
TXD  
RXD  
RTS  
CTS  
TXD  
RXD  
RTS  
CTS  
8
CTS-  
+5V  
10  
HEADER 10  
+5V  
MAX202ECSE  
(SOL16)  
GND  
Circuitry for J7- JRS232 Interface  
24  
3U MACRO-CPU Board Connector Pin-outs  
 
MACRO-CPU Hardware Reference  
J14, J17: MACRO COPPER I/O (OPT C)  
(8 pin RJ45)  
Front View  
Notes  
Pin #  
Symbol  
DATA+  
Function  
Data +  
Description  
1
Differential MACRO Signal. J17: DATA+ input.  
J14: DATA+ output.  
2
DATA-  
Data -  
Differential MACRO Signal  
J17: DATA- input.  
J14: DATA- output.  
See schematic below.  
See schematic below.  
See schematic below.  
See schematic below.  
See schematic below.  
See schematic below.  
3
4
5
6
7
8
unused  
unused  
unused  
unused  
unused  
unused  
Unused terminated pin  
Unused terminated pin  
Unused terminated pin  
Unused terminated pin  
Unused terminated pin  
Unused terminated pin  
The cable used for MACRO wired connections is CAT5 verified straight-through 8 conductor.  
J14  
rj45  
J14  
tx+  
tx-  
1
2
3
4
5
6
7
8
CON8  
50  
50  
50  
50  
50  
50  
50  
50  
50  
J17  
rj45  
J17  
rx+  
rx-  
1
2
3
4
5
6
7
8
U94  
14  
15  
16  
12  
11  
10  
CT  
TD-  
TD+  
CMT  
TX-  
TX+  
CON8  
3
2
1
5
6
7
CT  
RD-  
RD+  
CT  
RX-  
RX+  
50  
50  
50  
50  
50  
50  
PE-68515  
M3  
MTG HOLE  
50  
75  
75  
50  
50  
.01 mfd 2kv  
Circuitry for J14 and J17- Copper MACRO I/O  
3U MACRO-CPU Board Connector Pin-outs  
25  
 
MACRO-CPU Hardware Reference  
P1: UBUS Interface Connector  
(96 pin EURO-Connector at F-1, 2, 3, 4)  
Front View on MACRO-CPU Card  
Pin #  
1
2
Row A  
+5Vdc  
GND  
Row B  
+5Vdc  
GND  
Row C  
+5Vdc  
GND  
3
BD01  
DAT0  
BD00  
4
BD03  
SEL0  
BD02  
5
BD05  
DAT1  
BD04  
6
BD07  
SEL1  
BD06  
7
BD09  
DAT2  
BD08  
8
BD11  
SEL2  
BD10  
9
BD13  
DAT3  
BD12  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
BD15  
BD17  
BD19  
BD21  
SEL3  
DAT4  
SEL4  
DAT5  
SEL5  
DAT6  
SEL6  
DAT7  
BD14  
BD16  
BD18  
BD20  
BD23  
BD22  
BS1 (GND)  
BA01  
BS0 (GND)  
BA00  
BA02  
BA04 (n.c.)  
CS2-  
CS4- (CS6-)  
CS10-  
CS14-  
BA12 (n.c.)  
BWR-  
BS2 (GND)  
RESET  
SERVO+  
SERVO- (n.c.)  
GND  
BA03  
BX/Y  
CS3-  
BA05 (CS7-)  
CS12-  
CS16-  
BA13 (n.c.)  
BRD-  
BS3 (GND)  
n.c.  
PHASE+  
PHASE- (n.c.)  
GND  
SEL7  
BA06 (n.c.)  
BA07 (n.c.)  
BA08 (n.c.)  
BA09 (n.c.)  
BA10 (n.c.)  
BA11 (n.c.)  
MEMCS0- (n.c.)  
MEMCS1- (n.c.)  
n.c.  
n.c.  
n.c.  
-15Vdc  
GND  
+5Vdc  
PWRGUD (n.c.)  
GND  
+15Vdc  
GND  
+5Vdc  
+5Vdc  
1. Refer to the UBUS Specification for detailed signal descriptions. This interface is NOT VME bus compatible.  
2. Items shown in parentheses represent pin descriptions for -104 and earlier revision MACRO-CPU boards.  
26  
3U MACRO-CPU Board Connector Pin-outs  
 
MACRO-CPU Hardware Reference  
TB1: (JPWR) 4-Pin Terminal Block  
(Location B-4)  
Pin #  
Symbol  
Function  
Description  
Reference Voltage  
Positive Supply Voltage  
Positive Supply Voltage  
Negative Supply Voltage  
Notes  
1
2
3
4
GND  
+5V  
+15V  
-15V  
Common  
Input  
Input  
Supplies all PMAC digital circuits  
+12V to +15V; used for on-board analog  
-12 to –15V; used for on-board analog  
Input  
U73: MACRO Fiber Optic Connector (OPT A)  
(2 Socket SC-Style)  
Front View  
Notes  
Pin #  
Symbol  
Function  
Description  
1
2
RX  
TX  
Fiber Input  
Fiber Output  
MACRO Ring Receiver  
MACRO Ring Transmitter  
A. The fiber optic version of MACRO uses 62.5/125 multi-mode glass fiber optic cable terminated in an SC-style  
connector. The optical wavelength is 1,300nm.  
B. It is possible to "adapt" wire to fiber operation when using OPT A & C on the same MACRO-CPU board.  
3U MACRO-CPU Board Connector Pin-outs  
27  
 
MACRO-CPU Hardware Reference  
U MACRO-CPU HARDWARE MEMORY MAP  
The values in this table represent the hardware locations associated with register-based transactions that occur in  
the 3U MACRO-CPU.  
Reference  
CS00-  
CS02-  
CS04-  
CS06-  
CS0-  
ADDR (hex)  
$FFC0  
$FFC8  
$FFD0  
$FFD8  
$C000  
$C020  
$C040  
$C060  
$C080  
$C0C0  
$FFE0  
$FFE8  
$FFF0  
$FFF8  
$D000  
$E000  
Description  
Stack I/O select #1  
Stack I/O select #2  
Stack I/O select #3  
Stack I/O select #4  
Stack axis 1-4 select  
Stack axis 5-8 select  
UBUS backplane axis 1-8 select  
UBUS backplane axis 5-8 select  
On-board DSPGATE2 select  
CS1-  
CS2-  
CS3-  
CS4-  
CS4X-  
CS10-  
CS12-  
CS14-  
CS16-  
MEMCS0-  
MEMCS1-  
UBUS backplane MACROgate or DSPgate2 select (CS4- on UBUS)  
UBUS backplane I/O select #1  
UBUS backplane I/O select #2  
UBUS backplane I/O select #3  
UBUS backplane I/O select #4  
UBUS hardware I/O field (was DPRCS-)  
UBUS hardware I/O field (was VMECS-)  
The addressing field size is 16-bits in the 3U MACRO-CPU. The address table above is similar to the PMAC2  
product line.  
28  
U MACRO-CPU Hardware Memory Map  
 
MACRO-CPU Hardware Reference  
U MACRO-CPU Hardware Memory Map  
29  
MACRO-CPU Hardware Reference  
ACCESSORIES  
Both the Turbo and the MACRO CPU boards can support either the Stack or the UMAC configuration. The  
systems are configured modularly with the selection of a series of accessory boards, some appropriate for the  
Stack, and some appropriate for the UMAC. These accessories are listed here. Each has its own manual for  
detailed description.  
The following table shows 3U products by function:  
Board must be ordered with  
either Option A or Option C. connectors  
Option A, fiber-optic  
Option C, RJ-45 electrical  
MACRO connectors  
MACRO CPU Board  
Options  
ACC-1E, 2-Axis Interface  
Stack Board (UMAC  
MACRO only), 3x0-602810- 3x0-602805-10x  
10x  
ACC-2E, 4-Axis Interface  
Stack Board,  
ACC-3E, 48/96/144 TTL I/O  
Stack Board,  
3x0-602811-10x  
“Stack” Piggyback  
Accessory Boards  
ACC-4E, Isolated 24-In/24-  
Out Stack Board,  
3x0-602872-10x  
ACC-6E, 8/16-Channel 12-  
Bit ADC Stack Board,  
3x0-602810-10x  
ACC-24E2, 2-Axis Digital  
PWM, 3x0-603397-10x  
Option 1D, Additional 2-  
Axis Digital PWM,  
3D1-603397-10x  
ACC-24E2A, 2-Axis  
Analog, 3x0-603398-10x  
UMAC Backplane-  
Mountable  
Accessory Boards –  
Axis  
Option 1A, Additional 2-  
Axis Analog,  
ACC-24E2S, 4-Axis  
Stepper, 3x0-603441-10x  
3A1-603398-10x  
ACC-3E1, 48/96/144 I/O,  
3x0-603359-10x  
ACC-9E, 48 In,  
3x0-603283-10x  
ACC-10E, Isolated 48-  
Output Board,  
3x0-603299-10x  
UMAC Backplane-  
Mountable  
Accessory Boards –  
I/O  
ACC-11E, Isolated 24-In/24- ACC-12E, Isolated 24-  
ACC-14E, 48 I/O,  
3x0-603472-10x  
Out Board, 3x0-603307-10x  
In/24-Hi-Power-Out Board,  
3x0-603277-10x  
ACC-55E, (UNET)  
Universal Field Bus Adapter  
Network Card,  
UMAC Backplane-  
Mountable  
Accessory Boards –  
Communication  
3x0-603485-10x  
ACC-28E, 16-Bit A/D,  
3x0-603404-10x  
ACC-36E, A/D, D/A  
Converter, 3x0-603483-10x  
ACC-51E, X 4096  
Interpolator,  
3x0-603438-10x  
UMAC Backplane-  
Mountable  
Accessory Boards –  
Miscellaneous  
ACC-53E, SSI,  
3x0-603360-10x  
ACC-56E, Extender Card,  
300-603401-10x  
ACC-57E, Yaskawa or  
Mitsubishi ABS, Encoder  
Unit, 3x0-603484-10x  
ACC-58E, R/D Converter,  
16 Bit, 3x0-603482-10x  
ACC-U4, UBUS 4-Slot  
ACC-U6, UBUS 6-Slot  
ACC-U8, UBUS 8-Slot  
UBUS Backplane  
30  
Accessories  
 
MACRO-CPU Hardware Reference  
Backplane, 300-603462  
Backplane,  
300-603403-10x  
Backplane,  
300-603463-10x  
Boards  
ACC-U10, UBUS 10-Slot  
Backplane,  
ACC-U12, UBUS 12-Slot  
Backplane,  
ACC-U14, UBUS 14-Slot  
Backplane,  
300-603464-10x  
300-603465-10x  
300-603466-10x  
ACC-U16, UBUS 16-Slot  
Backplane,  
ACC-U18, UBUS 18-Slot  
Backplane,  
300-603471-10x  
300-603491-10x  
4-Axis Analog ± 10V Input  
Linear Amplifier, 24VDC,  
0.5/1A,  
4-Axis Analog ± 10V Input  
PWM Amplifier, 48VDC,  
2/4A, 300-603443-10x  
4-Axis Analog ± 10V Input  
PWM Amplifier, 70VDC,  
8/12A, 300-603486-10x  
Amplifiers – Analog  
±10VDC Input  
(Brush Motors)  
300-603489-10x  
Backplane, Double Analog  
Amplifier, 300-603470-10x  
Backplane, Single Analog  
Amplifier, 300-603490-10x  
2-Axis Digital PWM  
Amplifier, 360VDC, 4/8A,  
400-603391-10x  
2-Axis Digital PWM/Macro  
Amplifier, 360VDC, 8/16A,  
400-603392-10x  
Single Axis Digital  
PWM/Macro Amplifier,  
360VDC, 8/16A,  
Amplifiers – Digital  
PWM Input  
(brushless)  
401-603391-10x  
Single-Axis Digital PWM  
Amplifier, 360VDC, 8/16A,  
401-603492-10x  
Power Supply for 3U Digital Backplane, Digital PWM,  
PWM Amplifiers,  
400-603428-10x  
300-603435-10x  
ACC-F, 3U DC to DC  
Converter,10A,  
30F-603216-OPT  
Power Supplies –  
DC Input  
ACC-E, 3U AC Power  
Supply, 8A,  
30E-603269-OPT  
ACC-E1, 3U AC Power  
Supply, 14A,  
31E-603269-OPT  
ACC-E2, AC Power Supply,  
20A, 32E-603468-OPT  
Power Supplies –  
AC Input  
3U Rack, 10-1/2 Slot (42T)  
542-602932-10x  
3U Rack, 15-3/4 Slot (63T)  
563-602932-10x  
3U Rack, 21 Slot (84T)  
584-602932-10x  
UMAC Chassis  
Assemblies (Rack)  
3U Rack, Variable Width per  
Customer Requirements  
(custom design) ,  
500-602932-10x  
ACC-8DE, 2-Axis 3U  
Analog-Output Breakout  
Board, 3x0-603215-10x  
ACC-8FE, 2-Axis 3U  
Digital-Output Breakout  
Board, 3x0-603176-10x  
ACC-13, Encoder Terminal  
Block Board,  
300-603365-10x  
Hybrid Stack/Pack  
Accessories  
(Legacy Systems  
Only)  
ACC13A, Flag Terminal  
Block Board,  
300-603366-10x  
ACC-13B, Amplifier  
Terminal Block Board,  
300-603367-10x  
ACC-15E, Isolated 12-In/12-  
Out Opto22 Driver &  
Breakout Board,  
300-603488-10x  
Accessories  
31  

Freecom Technologies Firewire 400 User Manual
Electrolux Thermaline 9CHG584115 User Manual
Electrolux 922046 User Manual
Cypress FLEx36 CYD09S36V User Manual
Black Box Computer Hardware VX HDV 4P AUDIO User Manual
BenQ Computer Monitor G900WD User Manual
AT T 9230 User Manual
A T International CL82501 User Manual
Aluratek Tornado Plus AHDURS250F120 User Manual
Acer AL1917X User Manual