| SunScan   Canopy Analysis   System   User Manual   SS1-UM-1.05   Contents   Introduction.................................................................................................6   How to use the manuals............................................................................. 6   Organisation of this manual.......................................................................... 6   The SunScan Canopy Analysis System.................................................... 6   PAR measurements...................................................................................... 6   SunScan probe............................................................................................. 7   Beam Fraction sensor .................................................................................. 7   Data Collection Terminal .............................................................................. 7   SunData software ......................................................................................... 7   Field accessories.......................................................................................... 7   Getting Started............................................................................................8   Preliminary checks ..................................................................................... 8   The Workabout and SunScan probe ............................................................ 8   Checking the Workabout hardware .............................................................. 9   Installing the SunData s/w in your PC..................................................... 10   The SunData s/w Diskette.......................................................................... 10   Installing the s/w ......................................................................................... 10   Running SunData...................................................................................... 11   Setting up your PC's COM port .................................................................. 11   Communication checks:........................................................................... 12   SunScan probe to PC................................................................................. 12   Workabout to PC ........................................................................................ 12   Running SunData in Windows ................................................................. 13   SunScan Tutorial ......................................................................................14   About this tutorial..................................................................................... 14   What you will learn...................................................................................... 14   Using a portable PC instead of the Workabout .......................................... 14   Working with the Workabout ................................................................... 14   Powering up................................................................................................ 14   Navigating around the Workabout.............................................................. 14   What to do if you get lost............................................................................ 15   Starting SunData in the Workabout............................................................ 15   Using a PC instead of the Workabout ..................................................... 16   Starting the PC software............................................................................. 16   Setting up a measurement session......................................................... 18   Working through the menu options............................................................. 18   File Saving.................................................................................................. 19   "Hot Keys"................................................................................................... 19   Taking readings ........................................................................................ 20   Using the Emulator mode ........................................................................... 20   Without a Beam Fraction Sensor................................................................ 21   Connecting the SunScan probe.................................................................. 21   Connecting the Beam Fraction Sensor....................................................... 22   Measuring Leaf Area Index without a Beam Fraction Sensor .................... 23   Averages..................................................................................................... 24   Reviewing your data file........................................................................... 24   Transferring the data file to your PC....................................................... 25   Initiating the file transfer from the Workabout............................................. 26   RS232 communication problems................................................................ 28   Conclusion of the Tutorial........................................................................ 28   SunData Screens on the Workabout ....................................................... 29   SunScan User Manual v 1.05   • 3   Menus and Screens ..................................................................................30   More Psion and file handling notes.........................................................33   Navigating Psion directories and screens...............................................33   The Workabout User Guide........................................................................ 33   Navigating the Psion directories and screens............................................. 33   Psion subdirectory usage in file select dialogs ........................................... 34   Re-installing the SunData application icon.................................................. 35   Deleting unwanted Workabout files ............................................................ 35   Flashcards - reformatting............................................................................ 35   Data memory management .......................................................................36   Configuration and data file handling........................................................36   SunData Configuration files ........................................................................ 36   Data files..................................................................................................... 37   Displaying data files on your PC ..............................................................38   The .PRN file............................................................................................... 38   The .CSV file............................................................................................... 38   Data file layouts and data groups ............................................................... 39   Measurement options...............................................................................41   Experiment design.....................................................................................41   Above-canopy reference requirements....................................................... 41   Canopy type and BFS practicalities............................................................ 42   Canopy type and LAI estimates.................................................................. 42   Canopy Sampling volume........................................................................... 42   Preferred light and weather conditions ....................................................... 43   Planning for the sun’s position .................................................................... 43   Advice on Absorption and ELADP values ...............................................44   Absorption................................................................................................... 44   ELADP ........................................................................................................ 44   Relationship between Mean Leaf Angle and ELADP.................................. 45   SunScan System Measurement modes....................................................46   Workabout setup......................................................................................... 46   The Autolog function................................................................................... 47   Measurement procedures in the field.......................................................48   Probe handling in the field........................................................................... 48   BFS handling in the field ............................................................................. 49   PAR calibrations ......................................................................................... 51   Environmental and moisture protection ...................................................... 53   LAI theory...................................................................................................54   Ingredients of the LAI computation method............................................54   Derivation of Wood’s SunScan canopy analysis equations...................55   The major assumptions............................................................................... 55   Beer's law for canopy absorption................................................................ 56   Campbell's Ellipsoidal LAD equations......................................................... 56   Transmission of Diffuse Light...................................................................... 56   Modelling the canopy transmission............................................................. 58   Accuracy of LAI calculations....................................................................... 60   Functions used to model canopy transmission......................................60   Diffuse light - cosine response sensor........................................................ 60   Diffuse light - hemispherical response sensor. ........................................... 60   Modelling incomplete PAR absorption and scattering................................. 61   Calculating zenith angles ............................................................................ 62   Summary..................................................................................................... 62   Scientific references..................................................................................62   Technical Reference section....................................................................64   4 •   Document code: SS1-UM-1.05   Maintenance and repair............................................................................ 64   Checking the batteries................................................................................ 64   The SunScan probe batteries..................................................................... 64   The Workabout batteries ............................................................................ 64   Checking the desiccant .............................................................................. 65   Checking the PAR calibration..................................................................... 66   Troubleshooting........................................................................................ 67   Psion Workabout ........................................................................................ 67   Problems running the SunData application. ............................................... 67   While running SunData............................................................................... 67   Technical Support..................................................................................... 69   Distributor contact....................................................................................... 69   Direct Delta-T contact................................................................................. 69   Guarantee................................................................................................... 69   Problem Reports......................................................................................... 69   SunScan circuit schematics and data......................................................... 69   Locating version and serial numbers.......................................................... 69   Specifications ........................................................................................... 70   SunScan Probe type SS1......................................................................... 70   Beam Fraction Sensor type BF1 .............................................................. 70   Data Collection Terminal type DCT1 (Psion Workabout) ......................... 70   PC as Data Collection device ..................................................................... 70   Carrying Case type SCC1 ........................................................................ 71   Telescopic Tripod type BFT1.................................................................... 71   Spares Kit type SPS1 ............................................................................... 71   Logging Cables........................................................................................... 71   PAR Performance ..................................................................................... 72   Spectral response....................................................................................... 72   Cosine responses of probe and BFS.......................................................... 73   Appendices................................................................................................74   A. Logging the probe as a Linear Quantum Sensor............................... 74   B. Logging the Beam Fraction sensor..................................................... 75   C. Upgrading the SunScan system.......................................................... 76   D. File transfer between Workabout and PC........................................... 77   Choice of different programs ...................................................................... 77   PsiWin......................................................................................................... 77   SLINK and RCOM ...................................................................................... 78   Example using SLINK................................................................................. 78   Example using RCOM ................................................................................ 80   Documentation of RCOM and SLINK ......................................................... 80   E. Alternative file transfer mechanisms.................................................. 81   Sending a file to a Communication program............................................... 81   Sending a file to a serial printer .................................................................. 81   Using the Workabout COMMS application ................................................. 81   F. Glossary ................................................................................................ 82   Index...........................................................................................................84   SunScan User Manual v 1.05   • 5   Introduction   How to use the manuals   This manual tells you how to use your SunScan Canopy Analyser and its   accessories. Some pages in the Menus and Screens section are "Quick Guides"   which summarise the principal operating modes of the SunScan. They have been   laminated on to durable material so that they can be taken into the field instead of   the full manual. A separate Technical Manual is provided, but you will only need to   refer to it in exceptional circumstances.   If you have purchased the Psion Workabout Data Collection Terminal, you will need   to refer to its Workabout User Guide at first, to learn its basic operations. You may   also want to refer to your PC User Manual when setting it up to communicate with   the SunScan system.   Organisation of this manual   The sections are arranged in a practical order so that you can first of all check the   functioning of the equipment you have received, and then learn how to operate it   proficiently with the tutorials.   After this, there is a discussion of the measurement options that you must consider   when designing your experiments and taking readings in the field. The remainder of   the manual covers such things as the theoretical basis for leaf area index estimates,   and a technical reference section.   As a new user, you are recommended to work methodically through the Getting   Started, and SunScan Tutorial sections. Thereafter you may browse through other   parts of the manual as needed.   The SunScan Canopy Analysis System   Here is a brief overview of the main functions and components of the SunScan   system.   PAR measurements   Fractional interception and Leaf Area Index estimates   The SunScan probe is a portable instrument for measuring the light levels of   photosynthetically active radiation (PAR) in plant canopies. With it, you can   measure the interception of solar radiation by the canopy, and – in some types of   canopy – make estimates of canopy leaf area index (LAI).   PAR mapping   You can quickly take numerous readings to find the average level of PAR beneath   the canopy, for example, or make linear transects of the PAR distribution within the   canopy.   Autolog and Linear Quantum Sensor modes   The SunScan probe may also be left unattended to log the variation in PAR at one   place throughout the course of a day either in its fully functional Autolog mode, or   in its more basic Linear Quantum Sensor mode, connected to a data logger.   6 • Introduction   Document code: SS1-UM-1.05   SunScan probe   The light sensitive “wand” of the probe is 1 metre long, containing 64 photodiodes   equally spaced along its length. The probe handle contains batteries and electronics   for converting the photodiode outputs into digital PAR readings, which get sent to   your Data Collection Terminal via the RS232 link.   Beam Fraction sensor   The Beam Fraction sensor (BFS) also measures PAR light levels. It is used to   monitor the light incident on the canopy at the same time as you are making   measurements beneath it. The BFS incorporates two photodiodes, one of which can   be shaded from the direct solar beam by the shade ring. This allows the direct and   diffuse components of PAR to be separated, which is necessary for the computation   of LAI.   Data Collection Terminal   To observe and store readings from the SunScan probe, you need the Data Collection   Terminal (a Psion Workabout). The Workabout is a lightweight, robust field unit   with a full alphabetic keyboard for the annotation of readings. It comes with a   removable Flashcard which can be used for data storage and transfer.   You can use a portable PC as a data collection terminal instead, but it is less   convenient for field work.   SunData software   In order for the SunScan probe to communicate with the Workabout or a PC, it needs   software. We pre-install the Workabout's SunData software, and we provide the   SunData PC software on a 3.5 inch diskette which you must load into your PC. The   SunData PC software is a DOS program; it does not require Windows, but it can be   run in a DOS window. Data files are created in an ASCII text format which you can   import into spreadsheets or other applications for analysis on any PC.   Field accessories   The sturdy field Carrying Case is designed to accommodate all the components of   the SunScan system. It has room for an optional tripod mount which is intended   primarily for use with the BFS, but which can equally well be used with the SunScan   probe. Space is also provided for extension cables that may be ordered with the BFS.   SunScan User Manual v 1.05   Introduction • 7   Getting Started   After unpacking the SunScan consignment and checking the contents against the   packing list, you will want to know if everything is functioning correctly. All parts   of the system are checked at our factory before despatch, so you should not   anticipate trouble. If the SunScan carrying case is difficult to open, slacken the   pressure release screw which is built into the carrying case moulding.   If you are an experienced user, the functional checks can be done in a few minutes   with no difficulty. If you are a new user you will have to follow the steps below   carefully and systematically, which will inevitably take somewhat longer.   Check the Data Collection Terminal first (the Psion Workabout), and then use it to   check the SunScan probe. After that, you must install the SunData s/w on your PC.   This will enable you to confirm communications with the probe, and to establish the   data transfer link between the Workabout and your PC. Testing the Beam Fraction   sensor will be left until the tutorial.   Preliminary checks   The following instructions should enable you to do the preliminary checks as quickly   as possible, so explanations will be kept to a minimum.   The Workabout and SunScan probe   Step 1 - Getting a screen display   ♦ Unwrap the Workabout.   The screen should be blank.   ♦ Press the yellow On/Esc button.   A screen display should appear.   If it does, Step 1 is satisfactory.   If no screen appears, the Workabout may lack power. Proceed to the Workabout   hardware checks below.   If you cannot successfully follow through these procedures, this may be because   some starting condition is no longer set up exactly as it was when the Workabout left   our factory. Do not abandon the tests, but proceed as far as you can through the   successive steps.   Step 2 - Running SunData and communicating with the probe   The screen should be showing some icons, as above. This is the Psion system   screen.   If something else is on-screen, try the following:   ♦ Press On/Esc (this will escape from any menus).   ♦ Press ∪+X, that is: hold down the grey Psi key ∪ and press X. (This will exit from   any application that is running.)   Warning! Do not Exit from the System screen itself! If you get the Exit System   Screen? dialog press N. If you can't find the SunData application icon, it may have   been lost after exiting the System screen. Proceed immediately to the section on Re-   installing the SunData icon in More Psion and file handling notes to remedy the   situation.   8 • Getting Started   Document code: SS1-UM-1.05   After some minutes of inactivity, the Workabout screen will automatically blank   itself to save power. Press On/Esc once more to restore the screen display.   ♦ Now connect the SunScan probe to the RS232 port at the top of the Workabout.   Leave the BFS sensor disconnected.   ♦ Press the yellow arrow keys to select the SunData icon.(A black background   appears round the selected icon label.)   ♦ Press the yellow Enter button. (Enter always accepts the selected item.)   The SunData opening screen should   appear, with a heading indicating that a   probe is connected.   ♦ Press the red button on the SunScan   probe handle once or twice.   The Workabout screen should change.   If it does, Step 2 is satisfactory.   If you cannot get this step to work, you will have another chance to test the SunScan   probe after you have installed the SunData s/w in your PC.   Step 3 - Switching off the Workabout   ♦ Press ∪+X to exit the SunData program.   ♦ Press Off.   The screen will go blank.   Checking the Workabout hardware   You should now refer the Psion Workabout User Guide chapters 1 and 2 and start   familiarising yourself with the basic operation of the Psion (you will need to do this   more thoroughly when you reach the tutorial sections).   The Internal drawer   The Workabout hardware installed at despatch is listed below. You can check this by   pressing the drawer release button at the top left corner of the Workabout to open the   battery drawer. Check for:   a) Lithium backup cell installed.   b) One Ni-Cd battery pack installed, and charged.   c) Flashcard in internal drive slot A   The Psion Charger   This provides power to run the Workabout, and at the same time trickle-charges any   Ni-Cd battery that is installed.   ♦ Mount the Workabout into its Docking Unit, and connect the charger to it.   The indicator on the front of the Workabout will light up.   Spare Ni-Cd batteries are supplied uncharged. At the first convenient opportunity,   fit them in the Workabout and trickle-charge them fully (overnight).   This completes the initial checks to show that the SunScan probe and Workabout are   functioning. Now you must install the SunData s/w in your PC.   SunScan User Manual v 1.05   Getting Started • 9   Installing the SunData s/w in your PC   In this section you will be told about the SunData s/w, and what you need to do to   get it running on your PC. You will then use it to establish that your PC can   communicate with the SunScan probe.   The SunData s/w Diskette   What the s/w does   The s/w is provided as three groups of programs in separate directories on the   diskette. If you find a README file in the root directory of the diskette, please read   it. It may contain late release information not included in this manual.   SunData PC s/w (in the \PC directory)   You must install this in a PC for transferring data files from the Workabout to the   PC. You can also install it in a (portable) PC to enable the PC to act as a data   collection terminal instead of the Workabout.   SunData Psion s/w (in the \PSION directory)   This is a backup copy of the s/w that is pre-installed in the Workabout. You will not   use this except in the unlikely event of program loss from the Workabout.   Psion communications s/w (in the \COMMS directory)   These are DOS programs provided by Psion which enable you to transfer files   between the PC and Workabout. Full documentation is provided on disk and in the   appendices. They will not be further described in this section.   These programs are essential if you need to restore s/w lost from the Workabout,   (unless you have purchased the optional PsiWin Windows s/w), and of course they   give you alternative methods of transferring data files from the Workabout to your   PC, if you don't want to use SunData's own data file transfer method.   Installing the s/w   Your PC requirements   Your PC needs: DOS 3.3 or higher; a 3.5 inch 1.44 MB diskette drive, and an   available serial port with 9 pin D-connector   You may need to refer to your PC manual to carry out the following tasks: copy a   diskette, create subdirectories, copy files, and run programs from the DOS prompt.   You should make a copy of the SunData s/w diskette immediately for routine use.   Store the original diskette securely, and set the write-protect slider on the diskettes.   Copy all the diskette files to your hard disk drive (HDD). You are recommended to   use the same diskette directory names and to put them all in a parent directory, for   example: \SUNSCAN. At the same time, you should create another directory for   storing SunScan data files, e.g. \SUNSCAN\SSDATA. You may choose alternative   names for any of these directories if you wish.   ♦ Insert the SunData diskette in your PC's diskette drive.   ♦ Create the required directories on your PC's HDD.   ♦ Copy the files from the diskette to the HDD.   ♦ Remove the SunData diskette from the disk drive.   No problems should be experienced if you wish to de-install the SunData programs   later. Simply delete all the directories and files that you copied on to your hard disk.   10 • Getting Started   Document code: SS1-UM-1.05   Running SunData   The program you will run is SUNDATA.EXE (which was in the \PC directory on the   diskette). This will be a quick test just to obtain the opening SunData screens on   your PC.   From DOS   ♦ Change to the directory on your hard disk which holds the SUNDATA.EXE file.   ♦ At the DOS prompt, type: SUNDATA then ↵ or Return or Enter to run it.   The opening SunData screen will appear. SunData is running. You should see a   starting plaque similar to this:   ♦ Press the Tab key ( →| ) to select either <Color> or <Monochrome>,   then press ↵ to expose the first working screen (see below)   You will not see this starting plaque again, but you will always be able to choose   your screen mode from the system settings in the program.   The first working screen will look like this:   For the moment, ignore the connection instruction at the bottom of the screen,   because you need to tell your PC which COM port to use for the SunScan Probe.   Setting up your PC's COM port   ♦ Press Alt+S, then Y   The System Settings dialog box will appear:   ♦ Use the arrow keys to toggle between the   available COM port options.   ♦ Press the Tab key ( →| ) twice to move to <OK> , then press ↵   (You can also move there with ↑↓, Enter, or Shift+Tab.)   SunScan User Manual v 1.05   Getting Started • 11   Communication checks:   SunScan probe to PC   For this test you will need the SunScan probe, and the SunData PC s/w running in   your PC to the stage described above.   ♦ Now connect the SunScan probe coiled cable to the COM port you have just   specified, and press ↵ again.   The CONNECT option will be activated, and the screen will change to report the   connection.   ♦ On the SunScan probe handle, press the red "GO" button once or twice.   Further changes to the screen will occur.   Communication between the probe and your PC has now been demonstrated. Don't   worry if some of the numbers on the screen appear to be nonsense at this stage. You   will get a chance to set the probe up properly in the Tutorial section.   The SunData probe is supplied with alkaline batteries installed. The power is always   on, but the consumption is so low that new batteries will last for up to 1 year. After   taking readings with the probe, its battery voltage is reported in the screen title. The   cut-off voltage is 4700 mV.   Navigating and selecting options in the PC s/w   If you got lost in any of the above instructions, try again, using the following general   principles for moving around the screen:   a) Select an option by moving the highlighted cursor to it. Use the arrow keys or the   Tab key to move between options. Half-tone highlights indicate that options are   not available at that moment.   b) Accept the selected option by pressing ↵ or Return or Enter   c) Escape from, or cancel, a selection by pressing Esc   Menus at the top of the screen can be selected by pressing Alt + the highlighted letter   key (or using the arrow keys), otherwise the options at the bottom of the screen are   selected.   If you are familiar with the concept of "hot-keys", you will find them listed in the   menu dialog boxes, and you can use them straight away.   To exit or quit SunData   ♦ Press Alt+F then X, or Alt+Q then Q   The program will return you to the DOS prompt.   Workabout to PC   For the moment, if the Workabout and SunScan probe have responded to the Getting   Started operations, then the preliminary tests are complete.   Later on in the Tutorial section you will learn how to transfer data files from the   Workabout to the PC. If you ever need to transfer the program files from the PC to   the Workabout, this is dealt with in the appendices.   12 • Getting Started   Document code: SS1-UM-1.05   Running SunData in Windows   At this stage you may wish to install the SunData program so that it runs from within   Windows.   In Windows 3.11   The SunData diskette also contains SUNDATA.PIF and SUNDATA.ICO files for use   with Windows.   ♦ In Windows Program Manager, select File, New, Program Item   ♦ Specify SunScan for the Description, SUNDATA.PIF for the Command Line, your   program directory name for the Working Directory, and SUNDATA.ICO for the   Icon File.   Program Manager will then display the SunScan Icon.   Later on you can refine this arrangement, and call the program from a data   directory, but for the present it will get you started.   ♦ To run SunData: double click on the SunScan icon to run SunScan full screen.   ♦ To exit: press Alt+F, X, or Alt+Q, Q   In Windows 95   SunData will run from a Windows 95 DOS command prompt, or from an MS-DOS   mode DOS session launched from Windows 95. Do not try to run it under a   Windows 95 non MS-DOS mode DOS session. Then follow the general principles   given above for Windows 3.11.   SunScan User Manual v 1.05   Getting Started • 13   SunScan Tutorial   About this tutorial   What you will learn   This tutorial takes you step by step through the processes of setting up and taking   readings with the SunScan probe, and then transferring the data files to a computer   for analysis. It is divided into two parts, each of which should take about 20 to 30   minutes. For the first part you will need access to the Psion Workabout and its User   Guide, or to a portable computer if you are using that instead. The second part   requires access to the SunScan probe, the Beam Fraction Sensor if it is available, and   a computer for collecting and analysing the data files.   Using a portable PC instead of the Workabout   The SunScan can be controlled using either a Psion Workabout or a portable PC   computer. The instructions in this tutorial show the specific keypresses and SunData   screens for the Psion Workabout, but the layout of menus and the operating   principles are broadly similar if you’re using a portable computer instead. Read the   sections with the PC logo in the margin.   ♦ Instructions for you to follow are bulleted like this one.   Working with the Workabout   Powering up   If you haven't already done this in the Getting Started section, you should check that   the Workabout has a suitable power supply. This is explained in the introductory   section of its manual, page 3 onwards.   ♦ Press the yellow On/Esc button.   The Workabout screen should become visible.   If not, refer to the Troubleshooting section on page 17 of the Workabout manual.   ♦ Check the Workabout’s battery status by pressing Ctrl+Shift+B (hold down the   grey Ctrl and Shift buttons, then press B).   Navigating around the Workabout   Each time it powers up, the Workabout returns you to the same place in the   application you were last working on. Once you’ve got used to it, this is a very   useful feature, but it can be quite confusing when you first start. You may be   anywhere, in any application, and switching the Workabout off and on again won’t   get you back to the start.   ♦ Exit any current application by pressing ∪+X. (Hold down ∪ then press X)   This will take you to the Psion System   Screen. You should see a display   something like this. (If you can't find the   SunData icon, see Getting Started for   help).   14 • SunScan Tutorial   Document code: SS1-UM-1.05   Warning! If you were already in the Psion System Screen, you’ll see a message Exit   System Screen? Press N, so that you stay in the System Screen.   From this point you can launch SunData, the SunScan application, but first it is a   good idea to familiarise yourself with the Workabout’s keyboard. The main uses of   the keys are explained in the Workabout user Guide on pages 10 and 11.   The following keys are particularly important for the Workabout:   Pops up a menu of options relevant to your current activity   Menu   Move the cursor up and down menu options, or adjust the value of a set-   up parameter   ↑ ↓ Cycle through the available settings for a menu option   ← → Carry out highlighted activity, choose menu option or accept highlighted   setting   Enter   Exit from current activity or menu, abandoning any changes   On/Esc   Tab   Gives you and expanded range of choices, especially in file operations   What to do if you get lost   The important thing to remember is that you can get out of any menu by pressing   On/Esc, and out of any application by pressing ∪+X. This should get you back to the   Psion System Screen, as shown above. If things get really stuck, you may have to   reset the Workabout, as explained in its manual on page 20.   Starting SunData in the Workabout   ♦ In the System Screen, use the arrow keys to highlight the SunData application,   and then press Enter.   SunData will load and then flash up   communicating as it tries to connect to   the probe. Since you haven’t yet   connected the probe, it will let you know   that Communications failed, and display   this screen (the title screen):   Now, you need to tell SunData to work in Emulator mode.   ♦ Press Menu and then use the ← →   arrow keys to select the Settings menu,   which will look like this:   ♦ Use the ↑↓ arrow keys to highlight   SunScan Probe, and press Enter to pop   up a dialog box with options on which sensors you have attached.   ♦ Use the ← → arrow keys to change the   Data from: setting to emulator like   this:   ♦ Set the Ext sensor to BFS so that a   Beam Fraction Sensor will also be   emulated.   ♦ Press Enter to accept this setting and return to the title screen.   SunScan User Manual v 1.05   SunScan Tutorial • 15   Using a PC instead of the Workabout   Starting the PC software   Skip this section if you are using the Psion. Refer to the section in Getting Started   for details on starting the PC version of the SunData software. This should bring   you to the PC title screen. You will then set the probe into its emulator mode for the   first part of the tutorial, as follows:   ♦ Press Alt+S to drop down the Settings menu   as shown.   ♦ Move to the SunScan Probe option using the   ↑↓ arrow keys, and accept it by pressing   Enter or ↵   The SunScan Probe dialog box will appear.   ♦ Use the Tab or ↑↓ keys to highlight the Data from field.   ♦ Use the ←→ keys to toggle between the options in the field   ♦ Select the Emulator option   ♦ Move to the External Sensor field,   select the BFS option (it will be   emulated too)   ♦ Move to the <OK> field and press   Enter or ↵   The menu line at the bottom of the screen will now show only the CONTINUE option.   ♦ Press Enter or ↵ to get the following screen:   In the Setting up instructions that follow, you must interpret the Psion Workabout   instructions appropriately for your PC's environment. Don't forget the general rules:   a) Select an option by moving the highlighted cursor to it. Use the arrow keys or the   Tab key to move between options. Half-tone highlights indicate that options are   not available at that moment.   b) Accept the selected option by pressing ↵ or Return or Enter   c) Escape from, or cancel, a selection by pressing Esc   Menus at the top of the screen can be selected by pressing Alt and the highlighted   letter key (or moving the cursor to it with the arrow keys), otherwise the options at   the bottom of the screen are selected.   16 • SunScan Tutorial   Document code: SS1-UM-1.05   (This page is intentionally blank)   SunScan User Manual v 1.05   SunScan Tutorial • 17   Setting up a measurement session   Working through the menu options   In normal use the SunData software calculates Leaf Area Index (LAI) based on   readings from the SunScan probe and from the Beam Fraction Sensor (if fitted).   These calculations also require information about the distribution of leaf angles and   absorption of light by leaves within the canopy and knowledge of the solar angle   calculated from the time of day and local latitude and longitude.   SunScan probe   Beam fraction   Average PAR within canopy   PAR above canopy   ï ï Ratio of Direct to Total light   Leaf Angle Distribution   Leaf PAR Absorption   ELADP setting   Leaf Area Index   Absorption setting   Time and date   ï ï ü Latitude setting   Longitude setting   Solar zenith angle   Before it can make sensible calculations of the Leaf Area Index, SunData needs to   know what values to use for the above settings.   ♦ Press Menu, use the ← → arrow keys to   select the Settings menu, and the ↑↓   keys to highlight Site, and press Enter.   Type in a Name for your present site, and   set the Latitude and Longitude by   pressing Del and typing in the   appropriate values. When everything is   correct, to accept it   ♦ Press Menu again, then select Time & Date and press Enter. Now set the local   time and date in the dialog box. You also need to set the appropriate offset from   GMT for your time zone. Set Local time is GMT to between -12.0 and +13.0   hours. Remember to make allowance for any special seasonal offsets, such as   “Summer Time”, “Daylight Saving”. For example: British Summer Time is   GMT+1, India is GMT+5.5, and USA EST is GMT - 5.0.   ♦ Press Enter to accept the settings and return to the Title screen.   Note: The date and time formats can be changed, but for the moment just get the   information correct. To change am to pm, select it, and press p (or a).   ♦ Use the ← → arrow keys to set the Absorption to   0.85. Set the ELADP (Ellipsoidal Leaf Angle   Distribution Parameter) to 1. Press Enter to accept   these settings.   Later sections in Measurement Options and LAI Theory give explanations and   advice on choosing values for these parameters.   ♦ Set the Display format to LAI. Leave the ‘Sample’ and ‘Plot’ names unchanged.   The options for Display (LAI, PAR and All) have an important effect on the display   of readings but they also interact with the setting for Ext sensor (BFS or none) to   determine the sequence of readings required.   18 • SunScan Tutorial   Document code: SS1-UM-1.05   You will go through these different combinations later in the tutorial, and there is   also a route map in the Menus and Screens section.   These settings can be stored as a Configuration. Saving a number of configurations   enables you to switch quickly between the different set-ups necessary at different   sites, or when analysing the canopy of different crops with different characteristics.   Note: The Workabout’s file structure is very similar to a standard DOS system.   Files, such as SunData configuration and data files, are stored in hierarchical sub-   directories either in the Internal Disk (part of the Workabout memory configured as   a disk, called drive M), or on the Solid State Disks (SSDs) A and B.   ♦ Press Menu, File, Save Config’n.   Type in an appropriate Name for the   configuration. This will save it into the   \SUN\ directory on the Internal disk,   which for the moment will be   satisfactory.   Note: The Tab key is very useful when setting options generally - it pops up a   scrollable list of all the options available. It is particularly important when saving   and loading files, as it calls up a full list of all existing files and directories for you   to scroll through. Use On/Esc to exit from these directories.   Since you are just about to start taking readings, you also need to tell SunData the   name of the file you want to use for storing the data, and what file format you want   the readings to be stored in.   Press Menu, File, Data Storage, Enter. The default file setting is A:\DATA.PRN.   This will give you an easily Printable text file. If you prefer to work with   spreadsheets, choose the data file type Comma separated. For the Disk, specify A,   and for the moment ignore B and C. Do not put data files into the internal memory:   the space there is needed for other things.   File Saving   As soon as you have opened a data file, the SunData program looks after it for you.   The file will be automatically saved whenever you exit the SunData program or   when the Workabout is switched off. When SunData is re-started, the most recently   used file is automatically re-opened. New data will be appended to it - not   overwriting earlier data.   If you want to start a new file, type a new file name in the Store data to sub-screen.   "Hot Keys"   You may have noticed in the menus that many of the commands have a short-cut or   Hot Key combination, for example the dialog box obtained by Menu, File, Data   Storage, Enter can be invoked from the main SunData program simply by pressing   ∪+D.   Try these out from time to time as you become more familiar with SunData program.   Note however that if you are already in a dialog box, you will need to On/Esc from   it before the Hot Key will work.   SunScan User Manual v 1.05   SunScan Tutorial • 19   Taking readings   Using the Emulator mode   You have now configured all the settings necessary to start taking readings,   including setting SunData into emulator mode, with BFS, and setting the display to   LAI At its simplest, you only need to press Enter twice to take, display and store   each Leaf Area Index reading, and the values it is derived from:   ♦ Press Enter once to   collect and display an   (emulated) reading.   ♦ Press Enter again to   store that reading, and   return to the Next   Reading screen.   ....or possibly   Use the ← → arrow keys   to select DISCARD before   pressing Enter, in which   case the reading will not   be stored, ...and   optionally   ♦ Use the ← → arrow   keys to select NOTE   before pressing Enter, so that you can add a note to the reading before it is stored.   Reading labels uniquely   identify each reading.   They can be edited in the   Current time, and   calculated solar angle.   Next Reading screen by   using the ↑ key.   Spread of   readings from   individual   photodiodes   along the probe   wand.   PAR in µmol.m-2.s-1   above the canopy,   measured by Beam   Fraction sensor.   PAR within the   canopy, measured by   the SunScan probe   (or emulated).   Fraction of PAR in the   direct solar beam compared   to total incident PAR   (Direct + Diffuse) above   the canopy.   Leaf Area Index, calculated from   the readings shown and the   parameters entered earlier.   20 • SunScan Tutorial   Document code: SS1-UM-1.05   ♦ Now Set the Display to PAR (Menu,   Settings, Display, Enter)   The procedure for taking, displaying and   storing a reading stays the same, but the   reading display and the data stored   change to reflect the new setting:   This screen is the same if you change the Display to All, but the stored data also   includes readings from all 64 individual photodiodes.   Note: if you’re using a portable computer to control the SunScan, then the All   setting will actually display the 64 (emulated) photodiode readings.   Without a Beam Fraction Sensor   ♦ Change the SunScan probe, Ext sensor to none. (Menu, Settings, SunScan   probe, Enter)   The reading procedure is still the same   two-step process (read, store, read,   store...) without a Beam Fraction Sensor   - as long as you have the Display set to   PAR or All. However, the screen displays   only the average PAR reading from the   SunScan probe and the spread of the   photodiode readings.   Things get more complicated if you want to take Leaf Area Index readings without a   Beam Fraction sensor. SunData still needs measurements of the Incident PAR and   the Beam Fraction, so you have to make them using the SunScan probe itself. We’ll   go into the details of this procedure later on, once you have got the SunScan probe   connected.   Connecting the SunScan probe   By now you should have a reasonable familiarity with using the Workabout, and   how the SunData menus work, so it is time to try taking some readings with the   SunScan probe connected.   ♦ Plug the coiled serial cable from the probe into the RS232 connector at the top   right of the Workabout.   ♦ Use Menu, Settings, Display, Enter, and set the display to PAR.   ♦ Use Menu, Settings, SunScan probe, Enter, to set the Data from: to SunScan   probe.   ♦ For the moment, even if you have a BFS, set the Ext sensor: to none. Press   Enter to accept these settings.   SunData should display a version number at the top of the opening screen. If you see   Communications failed, you will need to recheck the connections.   If you don't get this far but get messages saying the serial port is in use, you must set   the Remote link to off. Exit from the SunData program if necessary (∪+X). From the   Psion System screen, press Menu, Spec, Remote link, Enter, and select Off. Then   restart SunData.   ♦ Press Enter in the Next Reading screen.   SunScan User Manual v 1.05   SunScan Tutorial • 21   This time you will see the value of the PAR reading from the probe. Now is a good   time to play around with the system a bit, shine a light on the probe, or take it   outside and poke it into a few canopies.   ♦ Press the red (GO) button to store the reading. Take a few more readings,   pressing Enter or the red button, and using NOTE, so that you store a few   annotated readings to your data file.   You may hear occasional beeps as you take readings. These are to help you keep   track of the reading process without constantly having to look at the Workabout: one   beep for READ, a double beep for STORE.(If you hate beeps, they can be turned off   - later!)   Connecting the Beam Fraction Sensor   If you have got a Beam Fraction Sensor...   ♦ Screw the BFS connector into the socket at the back of the SunScan probe.   ♦ In Menu, Settings, SunScan probe, Enter, set the Ext sensor: to BFS. Press   Enter to accept this setting.   ♦ Use Menu, Settings, Display, Enter, and set the display to LAI.   Now when you take readings, you will see a value of the Leaf Area Index.   Mount the BFS above the   canopy, with the arrow facing   North, level, and with the   Shade ring adjusted so that it   casts a shadow over the more   northerly photodiode .   SunScan probe   held level within the   canopy being   measured.   22 • SunScan Tutorial   Document code: SS1-UM-1.05   By now you may have accumulated quite a lot of readings in Data.PRN the default   data file. There is no harm in this, but you may want to put further test results into   new file, or maybe try out a .CSV file. If so, follow the Data Storage instructions a   few pages back.   Measuring Leaf Area Index without a Beam Fraction Sensor   This is the most complicated of the combinations of probe and display settings. The   Measurement Options sections discusses in detail the conditions for which it is   possible and desirable to make this measurement.   ♦ set the Ext sensor: to none.   The Next Reading screen now includes   extra options for reading INCIDENT and   B FRAC - and it won’t let you proceed   with a READ until you’ve taken these   readings.   ♦ Highlight B FRAC and press Enter.   Hold the probe level above the canopy as   before, but now cast a small shadow over   part of the probe. Don't hold the shade too   close to the probe - otherwise it will cut   out some of the diffuse light as well.   SunData looks at the readings from the   photodiodes and uses the lowest value to   calculate the Diffuse component of the   incident light. It uses the highest   photodiode values to calculate the Total   incident, and uses these two values to   calculate and display the Beam Fraction:   Note: SunData uses this value for the Beam Fraction to increase the accuracy of   the calculation of Leaf Area Index, as explained in the LAI Theory section.   However, this is a secondary effect, and you should not worry unduly about the   second decimal place for the Beam Fraction value.   ♦ Press Enter or the red button to STORE the Beam Fraction reading.   You can now continue to take readings with the probe and display the LAI as before   - that is, until the light conditions change, when you will need to retake the Beam   Fraction readings. If you wish to recheck only the incident light reading, you can do   so as follows:   ♦ Hold the probe level above the canopy, and make sure as little as possible of your   own outline is being seen by the probe.   ♦ Use the ← → arrow keys to highlight INCIDENT, and press Enter.   SunData will display the reading from   the probe:   ♦ Press Enter or the red button to store   this as the Incident PAR reading.   SunScan User Manual v 1.05   SunScan Tutorial • 23   Averages   SunData can calculate and store the average of all the samples in a plot, as well as   retaining each actual reading.   ♦ In the Reading screen, use the ← →   arrow keys to highlight the AVERAGE   option and press Enter.   You can then store, discard or add a note to   this average. After taking an average,   SunData will automatically increment the plot number.   In the LAI mode SunData calculates the following averages of the samples in the   plot:   • The average of all the Total incident light readings.   • The average of all the transmitted fractions (transmitted light/incident light ) for   each sample.   • The average of all the calculated LAIs for each sample.   In the PAR or All modes, the averages calculated are:   • The average of all the BFS Total readings (if the BFS is present).   • The average of all the SunScan probe readings.   Reviewing your data file   As soon as you have taken a few readings, you may want to look back over the   results before you transfer your data file to a PC. To review your file:   ♦ Press Menu, File, Review, Enter (or   ∪+V) to call up the dialog box as   shown.   You will be prompted with the current   data file name.   ♦ Press Enter to accept it.   The data file should now be visible. If it is cluttered with "" and ,, it is a .CSV file,   and you may format it for clarity. See below.   Owing to the small size of the Workabout screen you must scroll up and down or   sideways to view the whole extent of the file.   ♦ Use the arrow keys for scrolling in   continuous motion.   ♦ Use Shift+ the arrow keys to step a   screen at a time.   ♦ Use ∪+ arrow keys to move to the   ends of a file.   ♦ Press Menu for the list of hot keys, and other options.   These hot keys will take you to the top or bottom of the file, or allow you to zoom in   to three levels of magnification.   Note: you can in fact review the contents of any data file stored in the Workabout.   Just use the dialog box to choose a different file name.   If you have selected a comma separated (.CSV) data file instead of the default print   (.PRN) file, either   24 • SunScan Tutorial   Document code: SS1-UM-1.05   ♦ Select Format CSV: Yes in the Review dialog box   or from the file itself   ♦ Press Menu, Format CSV, Enter (or ∪+F)   This command in fact toggles between the formatted and unformatted states, and the   terminology changes accordingly.   Press On/Esc to exit from any of the dialogs, or from the reviewed file itself.   Note: if you’re using a portable computer to control the SunScan, the file is fitted   into one screen width, and you will be able to see a bigger area of the screen. You   can move throughout the file using ↑↓ PgUp, PgDn, Home, and End keys. You can   also view data files with any other text reading or spreadsheet application.   Transferring the data file to your PC   Now is the time to practice transferring a data file from the Workabout to your PC.   You will run SunData in the Workabout and SunData on the PC, and send the file   via the RS232 serial connection.   The SunData File Transfer system is intended only for transferring data files from   the Workabout to a PC. You can't use it for non data files, nor for transfers from the   PC to the Workabout. Other types of file transfer can be done with the utility   programs referred to in the appendices.   Of course, if you are using a portable PC as a Data Collection Terminal instead of   the Workabout, your data files will already be on the hard disk, and you won't need   to do this.   From the Workabout   On the Workabout:   ♦ Disconnect the SunScan probe coiled cable from the RS232 port on the   Workabout. Plug the (uncoiled) SunScan comms cable into the Workabout. For   the moment leave the remote end of the comms cable not connected to your PC.   If you get a "Failed to open Serial port in use" message, press On/Esc to clear the   message, then press ∪+L from the system screen. The Remote Link dialog box will   appear from which you must set the link to Off, and press Enter to accept it.   SunData should now run.   To the PC   Now proceed to your PC. If you haven't done so already, you should run SunData   and set up your PC's COM port as described in the Getting Started section of this   manual (access the System Settings dialog box by Alt+S then Y, or Ctrl Y).   ♦ Connect the SunScan (uncoiled) comms cable to the COM port you have   specified.   ♦ Select Alt+File, File Transfer, ↵   This calls up the File Transfer box which lets you specify the directory on your PC   into which you want the data file transferred. The current choice of directory is   shown in the top line.   If you want to change it, use the commands shown below.   SunScan User Manual v 1.05   SunScan Tutorial • 25   Navigating in the File Transfer box   • The Tab key (➙➙) will move you from one <field> to the next, in sequence.   Shift+Tab takes you back a step.   • The <Dirs/Drives> area shows you other drives that can be accessed. Use the ↑↓   arrows and press ↵ to select the drive or directory you want.   • "Sliders" on the side of the box give you an indication of where you are in the   complete list.   • ". ." takes you to the parent directory.   • "." Returns you to the current directory File box.   • The <Files> area shows you the filenames that are already used in that directory.   Use the ↑↓ or ←→ arrows to view the complete file listing.   You can't select or change these filenames here - they are listed so that you can see   what files you already have. Specifying the filename you want to save is done in the   next steps on the Workabout. Don't worry about over-writing an existing file, you   will be warned if this is about to happen.   You can quit this process at any stage by pressing Esc on your PC, or by selecting   <Cancel> and ↵.   ♦ When satisfied with your choice of directory, select <Receive> and press ↵.   A "Waiting for Data . . " message will appear in the files box.   Now move back to the Workabout for the final stage.   Initiating the file transfer from the Workabout   With SunData running in the Workabout:   ♦ Press Menu, File, File Transfer, Enter or (∪+R), for the file transfer dialog box.   You will be prompted with the current data file Name and Disk, but you could   choose any data file in the Workabout by following the on-screen prompts. For this   example we will continue with the A:\Data.prn file illustrated.   Now is your chance to specify the   filename you want the file saved as. If you   are happy with the send file Name, then   leave the save as showing ➙.➙.   ♦ If you want to change the name, use the ↑↓ arrows to select save as, and type in   your preferred filename.   ♦ Press Enter.   26 • SunScan Tutorial   Document code: SS1-UM-1.05   You will immediately get a "Sending" message showing the progress of the transfer   until it is completed, after which you will be returned to the SunData program.   If you have no more to do, you can exit SunData with ∪+X and disconnect the   RS232 comms cable.   If the process is not going according to plan, and you suspect problems with the   RS232 link, see the section below for help.   Meanwhile, on the PC...   Simultaneously with the sending message on the Workabout, you will see the file   being written on the PC screen, and a final confirmatory message that the file has   been sent correctly, if all was well.   ♦ Press Esc twice to exit the file transfer process, and then exit the SunData   program too (Alt+F, X).   The data file has now been copied to your PC, into the directory you have specified.   From there you can easily import it into spreadsheets or other applications for   presentation or further analysis.   In a later section (More Psion and file handling notes) you can find out how to   clean up your Flashcard by deleting files you have transferred to your PC.   SunScan User Manual v 1.05   SunScan Tutorial • 27   RS232 communication problems   RS232 links between computers are notorious for giving difficulties, because there is   no completely accepted international standard for them. If you are getting error   messages which indicate the link is not working properly, then the difficulties may   occur in a number of areas.   • The physical connections (the comms cable, the computer serial ports) may be   incorrect or defective.   • The RS232 data parameters of the sending and receiving computers must be   matched. (SunData takes care of the Baud rate, parity, and other data bit settings   for you, so this should not be the problem).   • Even if the above settings and connections are correct, the computers may be   sensitive to the exact order in which components are plugged in and the programs   run.   Try the following systematic process to resolve problems:   ♦ Exit from the SunData programs and disconnect the comms cable from the   Workabout and PC.   ♦ Switch off the Workabout and the PC.   ♦ Work through the instructions above again exactly in the order they are   presented, double checking the physical connection of the comms cable and the   COM port setting of your PC. Preferably work in DOS only.   The above instructions have worked successfully on a variety of portable and   desktop computers, with processors from 286s to Pentiums, and DOS versions from   4.0 to 6.2.   If you still have difficulty, try making the connections in a different order, or try   different PCs if they are available, or contact your agent or supplier, or Delta-T   Devices for technical support. If you are successful, make a note of the exact   process.   Conclusion of the Tutorial   By now you have used the SunScan to take practice readings in the emulator mode,   and you have set up the configuration to take readings with the probe itself in a   variety of modes (PAR, LAI and All). You have stored readings and been able to   review the data file and transfer it to the hard disk of your PC. These are the basic   operations which should enable you to explore other capabilities (such as the   Autolog mode, for example) without further detailed instruction.   If you are now keen to think about the practicalities of your next experiment then   skip to the section on Measurement Options. If not, you could consolidate your   familiarity with the Workabout and its file handling concepts in the next sections.   28 • SunScan Tutorial   Document code: SS1-UM-1.05   SunData Screens on the Workabout   Note: these screens   are only required if you   are measuring Leaf   Area Index (LAI), and   you do not have a   Beam Fraction sensor   attached to the probe.   Note: screen display and data stored   will be different from this if the Menu,   Settings, Display option is set to   either PAR or All instead of LAI.   SunScan User Manual v 1.05   SunScan Tutorial • 29   Menus and Screens   The following table shows the menu options and settings for the Psion Workabout.   Menus for SunData PC software follow a similar layout.   Type in name (and subdirectory) for the data file. .PRN or .CSV   extensions are added automatically, depending on data type.   Press Tab to display a list of files and directories on the specified   Disk. These can be selected too.   Name   ≤ 8 chars.   Data   Storage   File   A, B or   Internal   A and B refer to the Solid State Disks - see Workabout manual   page 12. Internal refers to the Workabout memory (RAM).   Subdirectory usage needs care! See User Manual.   Disk   Type   Print   File is a directly printable, ASCII file with appropriate formatting.   Comma   separated   File type is best for spreadsheets. Fields are enclosed in commas,   text in "...".   Data.prn   Prompts with current data file name, but any other name can be   selected, with Tab or ← →.   send file   Name   Transfer   see above   Disk   Type another name, or the "send file Name" will be used by   default.   save as   ➙.➙   Type in name for configuration file. Extension .CFG is added   automatically. Press Tab to display a list of files and directories on   the specified Disk.   Name   ≤ 8 chars.   Save   Config’n   see above   Disk   Name   Restore   Config’n   Use ← → or press Tab to display a list of possible .CFG files from   which to restore.   see above   Disk   View data file on the Workabout screen. Prompts with current data   Name   Review   file name. Select other names with Tab or ← →   see above   Yes, No   Disk   Yes hides the ",,," in a .CSV file. Has no effect on a .PRN file.   Format   .CSV   Zoom   Menu   For manoeuvring. Press Menu within a reviewed file. Gives rapid   scrolling, zooming to different magnifications, format/unformat of   .CSV files, and quitting the reviewed file.   Also, Shift+ arrow keys moves one screen at a time. ∪+↑↓ moves   to end of file   Top of File   Bottom of file   Format CSV   Quit   Exit the SunData program   Exit   SunScan   probe   Light readings are collected from the SunScan probe.   Data from:   Ext sensor:   SunScan   probe   Settings   emulator   Light readings are generated by the SunData software - used for   test purposes and for the Tutorial.   BFS   Incident PAR and beam fraction readings are collected from a   Beam Fraction sensor attached to the SunScan probe.   none   No external sensor is connected, and readings for incident PAR   and beam fraction (if required) have to be measured using the   SunScan probe itself.   0.5 to 1.0   0 to 1024   Set the leaf PAR absorption. 0.85 is typical.   Absorption   ELADP   Constants   Set the Ellipsoidal Leaf Angle Distribution Parameter, which   models the leaf angles within the canopy. 1 corresponds to a   random spherical distribution, 0 to vertical, and 1024 to horizontal.   Use 1 as default.   30 • Menus and Screens   Document code: SS1-UM-1.05   Title name is stored in the data file heading, and is displayed on   the Title screen.   Title   ≤ 40 chars.   Titles   Site   Settings   (contd.)   Name for a group of readings. A new name (or setting change)   starts a new group.   Group   ≤ 40 chars.   Name of your measurement site.   Site Name ≤ 40 chars.   Latitude -90° to +90°   Latitude of your measurement site. Use negative numbers south   of equator.   Longitude of your measurement site. Use negative numbers east   of Greenwich meridian.   Longitude -180° to   +180°   Set clock to the time at the measurement site.   Local time   Time &   Date   Today’s date.   Date   -12.0 to +13.0   Offset of local time zone from GMT. Remember to include   provision for any local “Summer” time etc.   Local time   is GMT   LAI   Display:   Display:   Display   Solar Zenith   Incident PAR   Transmitted PAR   Beam Fraction   Photodiode spread   Leaf Area Index   PAR   Display:   Transmitted PAR   Incident total PAR   Incident diffuse PAR   Photodiode spread   All   Same as for PAR, but individual readings stored to the data file.   Change name if ‘Sample’ is not appropriate.   'Sample'   name   ≤ 6 chars.   Change name if ‘Plot’ is not appropriate.   'Plot' name ≤ 6 chars.   Restores each photodiode's calibration coefficient as determined   by Delta-T.   Restore   Factory   Calibrate   Utils   Calibration   Calculate and reset the individual photodiode calibration   coefficients using the Beam Fraction sensor as a reference.   Recalibrate   SunScan   SunScan will operate unattended in whatever mode has been set-   up. Complete all the screen entries then press Enter to initiate   Autolog process.   Autolog   (setup   screen)   Date, time   Start   Type in start date and time. These can be in the past 24 hours to   allow alignment with particular periods.   Date, time   Stop   Type in date and time to finish. Must be in the future.   hh:mm:ss   Read   interval   Type in the sampling interval. Every reading is stored.   Minimum 00:00:01, maximum 23:59:59.   hh:mm:ss   Average   interval   Stores averages at the specified interval. Should be a multiple of   the read interval. Zero gives no averages.   yes, no   Ignore   nighttime?   Yes: readings are not taken at night.   No: readings are continuous.   Sleep, (or   Off)   Blanks the screen. This is the usual condition. Press On/Esc to re-   awaken it.   (progress   screen)   Cancel   Stops the Autolog process on demand.   Dumb terminal mode. Factory setup use only.   Comms   Test   Displays Psion SunData s/w version, and the battery voltage and   status for both the SunScan probe and Workabout.   About   SunScan User Manual v 1.05   Menus and Screens • 31   Exit the SunData program   Quit   32 • Menus and Screens   Document code: SS1-UM-1.05   More Psion and file handling notes   Navigating Psion directories and screens   The Workabout User Guide   At this stage you may want to learn more about operating the Workabout, so you   should refer again to the Workabout User Guide in which the following subjects are   well covered.   • Keyboard and LCD screen - pages 8,9   • Key functions and combination keypresses - pages 10,11   • The System Screen and Menus and dialogs - pages 38-42   • Solid State Disk drives - pages 12, 35   • Basic operation and troubleshooting - pages 13,14,16,17-20   When the User Guide refers to "application developers" and functions under   "application control", this means that Delta-T and the SunData program may use   some of the keys for special functions.   Warning! Look at "Changing the system-wide settings" - pages 23-24, but for the   moment do not change any of these! They may well make the SunData screens look   or behave somewhat differently from the examples in the SunScan documentation.   General principles   Remember the general rules for moving around Psion screens:   • The cursor (inverse video) highlights an available option   • Move the cursor with the yellow arrow keys to select options   • Press Enter to accept an option   • Press Menu to view lists of menus   • Press Tab to view alternative choices   • Press On/Esc to exit from menus or screens without changing them   • Press ∪+X to exit from any application   • Press Off to switch off   • Press On/Esc to resume exactly where you were before switching off   • Press Shift+On/Esc for Help (but not in SunData screens).   "Hot keys"   You will see that many menu options provide a hot key combination for rapid access   - for example pressing ∪+L in the Psion System Screen will take you straight into the   Remote Link dialog box. This is often a very convenient form of "shorthand" for   keyboard operations when you have learnt them. Note though, that the hot keys are   application specific - pressing ∪+L in the SunData program will take you to the   Autolog function.   Navigating the Psion directories and screens   The Workabout's file directories are structured just like DOS, but because the Psion   screen is much more limited for space, the method of displaying and navigating   around the directories is illustrated in the following examples.   SunScan User Manual v 1.05   More Psion and file handling notes • 33   This is the Psion System screen. If you   cant see the application you want, use the   yellow left or right arrow keys to scroll   through the range.   To get to the directories press   Menu, then the yellow arrow keys   to select Disk, Directory, and then   press Enter   Warning! Do not Exit (∪+X ) from the   System screen otherwise you will get this   Psion Logo startup screen and lose your   SunData icon. Avoid this screen! To get   back to the System screen follow the   directions: press Menu, then select   System screen, and press Enter. Then   refer below to re-install the SunData   application icon.   This symbol indicates the parent   directory. To move there, select it,   and press Enter.   This shows the Disk and subdirectory   you are in, whose files are listed in the   bottom panel.   The files in the subdirectory are   listed here. To operate on the   highlighted file press Menu for   various options.   To scroll through other disks,   press the yellow left or right arrow   This is the root directory of the   Internal Disk.   To scroll through the list, press the   up or down arrow keys.   Psion subdirectory usage in file select dialogs   In the Workabout file selection dialogs, you are only presented with information   about the file name and the drive it is on. No subdirectory information is given, and   this can cause confusion.   You can see which subdirectory you are currently working in by pressing Tab to   bring up the file directory display.   If you change the filename or drive in the dialog, you should be aware that the   Workabout takes the subdirectory information from the original file, unless you   specify otherwise. For example, if you copy a file from the root directory on drive A:   to another drive, it will be copied into the root directory of the drive you are copying   to.   34 • More Psion and file handling notes   Document code: SS1-UM-1.05   To copy to another subdirectory, you must add that information to the filename you   choose. If you only put a subdirectory name in the filename field, then the   Workabout will use the original filename, but with the new subdirectory. A   subdirectory name always starts and ends with “\”, for example \SUN\. If you are in   any doubt about what is happening, include the complete subdirectory path and   filename (but not the drive) in the filename field.   Re-installing the SunData application icon   If the Psion Logo Start-up screen (see previous page) has been accessed, the   SunData application may not be automatically re-installed on returning to the Psion   System screen, and the SunData icon will no longer be shown.   Re-installing SunData is quite simple. From the Psion system screen:   ♦ Press Menu, Disk, Directory, Enter and make sure that the files SunData.app   and Sys$8087.ldd are present in the \SUN\ directory on the Internal Disk. Press   On/Esc to return to the System screen.   ♦ Press Menu, Apps, Install, Enter, Tab, then move to \SUN\ and press Enter, then   select SunData.app and press Enter.   You will now see the Install dialog box with Filename SunData.app specified.   ♦ Check that Disk is specified as Internal. The Position of the icon in the System   screen can be specified too. When all the settings in the dialog box are   satisfactory, press Enter to accept them.   The Sundata icon should now be present in the System screen.   The identical process can be used subsequently for installing an upgraded version of   the SunData.app program if one is issued.   Deleting unwanted Workabout files   You can delete files from the either the internal memory or the SSDs of the   Workabout using its own file handling procedures as follows:   ♦ On the Workabout, exit from SunData (if necessary) by pressing ∪+X.   ♦ In the System Screen, press Menu, Disk, Directory, Enter.   ♦ Press ← or → to select Disk [A] (or whichever Disk your file is on).   ♦ Press ↑ or ↓ to highlight the filename of the file you want to delete.   ♦ Press Menu, Delete file, Enter, then respond to the confirmatory dialogue box.   You will find that no extra space is created on your SSD by deleting the files. The   only way to liberate space on the SSD is to re-format it after removing all valuable   files from it.   Flashcards - reformatting   The Flashcard (SSD) medium (unlike the Workabout internal memory) is such a   secure form of data storage that the only way to make it rewriteable is to reformat it.   If your Flashcard drive directory shows much less free space than the you would   expect from the difference between 256K (the full amount) and the files shown on it,   then you may want to reformat it. Check this with:   ♦ Menu, Disk, Directory, Enter, then select the drive with ← or →   Reformatting will destroy any files left on the Flashcard. Make sure you have   already transferred all valuable data files to a PC using SunData's file transfer   procedure.   SunScan User Manual v 1.05   More Psion and file handling notes • 35   If you have other (non-data) files you want to keep, copy them to the internal drive,   or to another Flashcard for temporary storage (don't forget to copy them back and   delete them immediately afterwards), alternatively copy them to your PC using   RCOM or SLINK, or the PsiWin program if you have it.   ♦ On the Workabout, exit from SunData (if necessary) by pressing ∪+X.   ♦ In the System Screen, press Menu, Disk, Format disk, Enter.   Then follow the instructions and prompts carefully.   Warning! Reformatting is an irrevocable process - you will get on-screen warnings   that files will be deleted. Also, do not format the Internal drive - you will lose your   SunData program!   Data memory management   The memory space taken up by a given number of readings can't be specified exactly   because it depends on how many notes have been included, the number of data   groups used, whether the file is a .PRN or a .CSV file, and so on. The following   estimates will however give you a useful guide when planning experiments.   For the standard 256K Flashcard, about 2500-3000 readings can be stored in the LAI   and PAR modes. This reduces to about 400-500 in the All mode, which retains the   64 individual diode values for each reading. The optional 1 Mb Flashcard can   accommodate about four times these amounts.   You can check the available memory space on your Flashcard from the Psion system   menus as indicated in the previous paragraph. Bear in mind the note about creating   space on the Flashcard.   Warning! Don't be tempted to store data files in the internal memory even though it   may appear to have plenty of free space. The SunData program uses a lot of this   space when running, and will refuse to run without it.   Configuration and data file handling   Opening and closing files in the SunData programs follows a somewhat different   routine from that used by applications run in desktop PCs because of the   Workabout's Solid State Disks.   Two sorts of files are involved: data files which are used for storing measurements   made by the SunScan; and configuration files, in which you can retain the settings of   different sites and experiments.   SunData Configuration files   Configuration files contain information on the state of the SunData program, which   includes the following Settings menu and readings information:   • SunScan probe and External sensor settings   • Site and local time details.   • Leaf constants (Absorption and leaf angle distribution parameters).   • Display mode for readings (LAI, PAR or All).   • Title and reading Group names.   • The Plot and Sample numbers of the last reading taken.   • The filename, subdirectory and file type (.PRN or .CSV) for data storage.   36 • More Psion and file handling notes   Document code: SS1-UM-1.05   Default .cfg   Every time you exit the SunData program, the program state is stored in the file -   Default.cfg. This configuration is restored when the SunData program is next run,   which means that you start again exactly where you finished last time.   Configuration files can help you if you want to alternate between different sites with   different settings. Set up the appropriate titles, settings and data file information for   each site you have, and save them to separate configuration files. Use a separate data   file for each site.   When you visit a site, Restore its configuration file before you start taking readings   there, and Save it again when you finish. Do this each time you visit a site. This will   give you a separate data file for each site, and the readings will follow on   sequentially within each file, as if you had been at that site without interruption.   Creating a configuration file   You create a configuration file by saving it with a specific file name.   ♦ Run SunData in the Workabout, and set up as many of the above details as you   can establish beforehand (press Menu, Settings, etc; and Menu, File, Data   storage, etc).   ♦ Press Menu, File, Save Config'n, Enter. You will be prompted for a name and   Disk location.   ♦ Press ← → or Tab to survey the subdirectory in which your file will be saved.   Specify a different name from any of these to create a new file, or select one of   the existing files (which will then be overwritten).   Restoring a configuration   ♦ In the SunData program on the Workabout, proceed to Menu, File,   RestoreConfig'n. Press ← → or Tab to survey the list, and then select the .cfg   file that you want to restore.   Data files   A data file is automatically opened whenever you enter SunData. The initial default   file name is A:\DATA.PRN. When you take readings, they are appended to this file,   that is to say the new readings are added to the end of it, and do not overwrite it.   The value of this feature will become apparent when you want to alternate between   plots with different measurement displays. Your data files will be easier to read and   process if they contain only measurements of one type. However, there is absolutely   no restriction on what types of readings a data file can accept.   When you switch off, the file is automatically saved. You cannot forget to save, and   thereby lose readings. When you switch on again, the same file is open ready to   receive more data. There is no "data file close" command.   Changing the data file   If you want to store data in a different file (or change the file type from .PRN to   .CSV) at any time, you must specify a different filename and type (and location) for   it.   ♦ Select Menu, File, Data storage, Enter for the appropriate dialog box. You can   either create a new filename, or select an existing file to append the data to it.   Don't forget that a Configuration contains the filename of the data file it uses. When   changing from plot to plot, you may prefer simply to restore a different   configuration.   SunScan User Manual v 1.05   More Psion and file handling notes • 37   Displaying data files on your PC   As soon as you have transferred data files from the Workabout to your PC (or have   created them on a portable PC) you will want to analyse and print them for your   records.   The .PRN file   The .PRN file format contains ASCII characters which can be read by a wide range   of text reading programs, and by some spreadsheets. An example printout is shown   below.   Created by SunData for Workabout v0.11   Title   :Demonstration   Location :Burwell, Cambridge   Latitude :52.2N   1996-05-19   Longitude :0.4W   Local time is GMT+1 Hrs   SunScan probe emulator   Ext sensor:BFS   Leaf Angle Distn Parameter: 1.5   Leaf Absorption : 0.85   Group   1 :Presentation   Time   Plot   Sample Trans- Spread Incid- Beam Zenith LAI Notes   mitted   ent   frac Angle   15:51:12   15:51:59   15:52:08   15:52:16   15:52:24   1 1 1 1 1 1 2 3 4 5 270.9   189.6   1047.5   63.4   0.13 2000.0 0.65 46.5   0.14 2000.0 0.65 46.6   0.15 2000.0 0.65 46.6   0.14 2000.0 0.65 46.6   0.15 2000.0 0.65 46.6   2.7 Notes appear here.   3.2   0.8   4.7   0.6   1225.3   Average of   5 readings:   Incident light: 2000.0 Transmitted fraction:0.28   LAI: 2.4   The .CSV file   The Comma Separated Value format is a common format where ASCII characters   are separated into fields by commas, and text is identified by being enclosed in "...".   This greatly simplifies importing the files into spreadsheets for further analysis and   printout. The example below was created in Microsoft Excel 5.0   Created by SunData for Workabout v0.11   Title   : Demonstration2   Location : Burwell, Cambridge   Latitude : 52.0N   19/05/96   Longitude :0.1W   Local time is GMT+1 Hrs   SunScan probe emulator   Ext sensor: None   Leaf Angle Distn Parameter:   2.5 Leaf Absorption :   0.9   Group 1 : Presentation2   Time   Plot   Sample Trans-   mitted   Spread   Incid-   ent   Beam   frac   Zenith   Angle   LAI   Notes   15:56:54   1662.4   0.37   Beam Fraction measm't   15:57:54   15:58:00   15:58:05   15:58:09   15:58:15   1 1 1 1 1 1 2 3 4 5 754.2   0.15   47.5   0.9   2.9   2.5   2.2   1 142.9   203.4   255.4   701.4   0.15   0.15   0.17   0.13   47.5   47.5   47.5   47.5   Average of   Incident light:   5 readings:   1662.4 Transmitted fraction   0.25 LAI   1.9   38 • More Psion and file handling notes   Document code: SS1-UM-1.05   Data file layouts and data groups   If you want to get a good idea of how the data files will look, you can run the PC   SunData program in the emulator mode. The general presentation of the results on   screen will be similar to that in the eventual data file.   The one major exception to this is in the All mode when the 64 individual   photodiode readings are listed. On the PC screen they are shown as 4 rows of 16   values, whereas in the .CSV data files they occupy 64 adjacent columns (from handle   to tip of the probe) to the right of the notes field.   A single data file can contain a mixture of layouts. The column headings will be   different for different combinations of equipment (BFS or not) and measurement   (LAI or PAR or All) that you have chosen. Each time there is a change, the headings   and titles will be revised to start a new group and give you a complete "audit trail"   for your measurements. Each group contains readings with exactly the same settings.   When a new group is started, you can create a group title for it from Menu,   Settings, Titles, Enter. The group title is automatically cleared when a new group is   formed.   Group numbering   Data groups are numbered sequentially, starting from group 1 when the data file is   created. You can't edit the group number (in the way that you can edit Plot and   Sample numbers), but you can give it a title.   The group number is incremented automatically whenever you re-start the SunData   program after exiting, or when you change a critical setting, that is:   • any parameter in the Settings menu   • any data or configuration file change.   SunScan User Manual v 1.05   More Psion and file handling notes • 39   Measurement options   Experiment design   This section discusses the factors that bear on the experimental objectives you wish   to achieve. It should help you answer questions like:   • What equipment do I need?   • What readings must be taken?   • Will I have to wait for particular times of day or weather conditions?   The type of study you propose to do will determine the time of year and duration of   the experiment, and whether you are interested, for example, in monitoring growth   by interception of solar radiation, or perhaps in the canopy structure as well.   Some canopies types (the non-uniform ones) preclude the use of the SunScan’s   direct LAI readout. You could, however, characterise the 3-dimensional light   distribution within your canopy at different heights, or along transects through it. For   brevity we will call this approach “PAR mapping” in the discussion below   Answers to the above questions are complicated, but the following tables should   give you a good appreciation of the main issues involved.   Above-canopy reference requirements   This refers to measurements of PAR incident on the canopy, made at the same time   as the below-canopy measurements. The question is whether to use a BFS.   Beam Fraction sensor   A BFS connected to the SunScan probe provides the best option, because you can   operate with fewest restrictions. However, with some canopy types this may not be   practical.   The next best option is to use the SunScan probe (without the BFS) sequentially   above and below the canopy, but you may be restricted to times when the light levels   are not changing fast.   Independent PAR sensor   If that method is not practical either, you may have to rely on independent records of   incident PAR from a separate sensor. In addition to slowly changing light levels, you   may also have to average measurements in each place over periods of a few minutes,   furthermore the direct LAI readout is not available. This is the least convenient   situation, and it will not always be considered in the analysis below.   You cannot currently use the SunData software to merge independent records of   transmitted PAR and incident PAR to get LAI.   Direct and Diffuse components   Assuming that you make your above-canopy measurements on the SunScan (with or   without a BFS), then the next table summarises whether you need to measure the   Direct and Diffuse components of the incident light. If you do not need the separate   components, you benefit because the BFS is quicker to set up (there is no need to re-   adjust its shade ring, once it has been set up correctly).   Type of study   Incident PAR   Total only   Yes   Incident PAR   Direct & Diffuse components   No   Yes   Fractional interception   LAI   No   PAR mapping   Yes   Possibly   SunScan User Manual v 1.05   Measurement options • 41   Canopy type and BFS practicalities   Canopy type is the next variable to be considered. As a general guide, the above-   canopy reference measurements should be made close to, or above, the position of   the SunScan probe. Tall canopies will undoubtedly exercise your ingenuity in   achieving this! If you want to use the BFS for LAI readings you must be able to see   the top of it to set the shade ring correctly.   Canopy   type   Options   Comments   Low   BFS connected, with extension   cables, if necessary.   No BFS   Best, but long cables need   management   Slower. Needs slow-changing light   conditions   Good when possible. Checking BFS   shade ring difficult.   Needs steady light conditions.   Clearing light may be partly shaded.   Needs slow-changing light, and   possibly time average readings. LAI   readings not available.   Low   High   High   High   Devise a portable BFS mount. Use   extension cables.   Use clearings to get out from under   the canopy. (No BFS required)   Use independent sensor for above   canopy PAR.   Canopy type and LAI estimates   Some types of canopy do not conform well to the assumptions about canopy   structure used by the SunScan in calculating LAI. The following table will give you   an initial idea of whether it is applicable to your canopy. You should read the   chapter on the LAI theory for a fuller appreciation of the subject. Some guidance on   specifying values for the typical leaf angle (the ELADP parameter) and leaf   absorptivity of your canopy comes later in this section.   Canopy type   Comments   Low, uniform (e.g. cereal crops, trial Good for LAI   plots)   Low, regular but not uniform (e.g.   row crops)   Absolute LAI dubious. May show valid trends. PAR   mapping   Isolated trees or bushes (e.g.   orchard trees)   PAR mapping only   sparse vegetation (e.g. scrub)   high, uniform , not clumped (e.g.   some timber plantations)   high, clumped vegetation (e.g.   natural woodland)   PAR mapping only   In principle good for LAI, but practical difficulties for   above-canopy reference   PAR mapping only   Canopy Sampling volume   It is useful to be aware of the volume of the canopy that the SunScan is "seeing"   when calculating LAI, so you can take this into account when planning your   sampling scheme.   With the Direct beam, the SunScan only sees the canopy elements along a 1 metre   wide sheet between the probe and the sun. With Diffuse light, the SunScan sees a   much larger volume, covering a region centred on the probe, extending out   approximately as far as the canopy is high, but with the canopy above the probe   making the greatest contribution. These two very different sampling volumes are   measured in the same proportions as the incident Direct and Diffuse light.   42 • Measurement options   Document code: SS1-UM-1.05   This means that in strong sun (high Beam Fraction) the canopy volume sampled is   fairly small and well defined. As the Beam Fraction decreases, the volume sampled   increases, and has less well defined limits.   Preferred light and weather conditions   These also will significantly influence your field operations.   Limitation   Comments   Time of day   Preferably within 3 hours either side of solar noon depending on   the location and season, to meet the next two conditions.   Measurements are easier when the sun is high. Probe and BFS   levelling errors become larger beyond zenith angles of greater   than 60°, especially for LAI   Solar zenith angle   Incident light level -   absolute   Preferably above about 200 µmol.m-2.s-1. Accuracy degrades   below this figure.   Light level - rate of   change   With the BFS, avoid only the very fastest changes between bright   sun and cloud.   With no BFS: slow-changing conditions needed.. For LAI, with no   BFS, slow change of direct and diffuse components.   SunScan LAI model copes with both, but full sun will usually give   the best results. Broken cloud is also satisfactory.   Full overcast, or full   sun in blue sky   Planning for the sun’s position   The SunData software on the PC contains a useful calculator for solar zenith angles   on any date, to help you plan appropriate times to make your measurements. This   can be accessed from the Utilities menu Alt+Utilities, Zenith calculator. The default   values are taken from the Site Settings you are currently using, but can be changed   within the solar predictor without affecting any settings elsewhere in the program.   SunScan User Manual v 1.05   Measurement options • 43   Advice on Absorption and ELADP values   Absorption   Absorption is the percentage of incident PAR that is absorbed by the leaf.   Most leaves have Absorption values in the range 0.8 - 0.9, so the default value of   0.85 will usually be appropriate.   Only adjust the Absorption value if you have good reason to, for example if you are   working with very thick, dark leaves, or very thin transparent ones.   If you set the Absorption value to 1.0, the LAI calculations will be equivalent to   simpler models that assume completely black leaves.   ELADP   ELADP is the Ellipsoidal Leaf Angle Distribution Parameter.   The ELADP is a way of characterising the horizontal or vertical tendency of leaves   in a canopy.   The canopy leaf elements are assumed to be   distributed in space in the same directions and   proportions as the surface area of an ellipsoid of   revolution, symmetrical about the vertical axis.   The Leaf Angle Distribution can then be   V described by a single parameter, the ratio of the   Horizontal to Vertical axes of the Ellipsoid.   H ELADP = H V   This is also equal to the ratio of the vertically projected area to the horizontally   projected area of the ellipsoid (or of the canopy elements).   • An ELADP of 1.0 gives a spherical Leaf Angle Distribution, where all leaf angles   are equally represented.   • A high ELADP (e.g. 1024) represents a broad flat ellipsoid, i.e. the leaf elements   are all horizontal   • A low ELADP (0.0) represents a tall thin ellipsoid, i.e. all the leaf elements are   vertical.   Most crops have ELADPs in the range 0.5 - 2.0.   Setting ELADP   The default setting of 1.0 (spherical leaf angle distribution) is a good starting point.   If you are unable to estimate the ELADP any other way, set ELADP to 1.0. You can   check how much this affects your results in the field by making several   measurements in one place within a canopy using different ELADP values, and   comparing the LAI values calculated.   44 • Measurement options   Document code: SS1-UM-1.05   Estimating ELADP in the field   If the canopy shows a clear predominance of horizontal or vertical leaves, then   choose a small volume of the canopy that is representative. Count the number of   leaves that are at more than 45° from the vertical (i.e. mostly horizontal), and the   number of leaves that are less than 45° from the vertical. If the leaves are curved,   pick the angle at the widest part of the leaf. The ELADP can be estimated as the   number of horizontal leaves (Nh) divided by the number of vertical leaves (Nv),   multiplied by π/2 (1.6).   π 2 Nh   Nv   ELADP =   The factor π/2 comes from the fact that the vertical leaves are distributed about the   vertical axis, so for any light ray, some will be seen face-on, and some edge-on. In   effect, the ellipsoidal distribution is being further approximated as a cylindrical   distribution.   If you set ELADP to 1024, and Absorption to 1.0, the LAI calculations will be   equivalent to the simple Beer’s law inversion based on black, horizontal leaves.   Relationship between Mean Leaf Angle and ELADP   Wang & Jarvis (1988) describe the relationship between ELADP and the Mean Leaf   Angle, which is sometimes known from other studies. Their results are summarised   by the following graph:   90   80   70   60   50   40   30   20   10   0 0.01   0.1   1 10   100   ELADP   SunScan User Manual v 1.05   Measurement options • 45   SunScan System Measurement modes   Workabout setup   With your planned experiments in mind, you should now know what measurements   you want to make, and what equipment you will need. The following section   describes the three display functions that you may use, and gives advice on the   handling of SunData configuration files.   The LAI, PAR and All displays   (Note that the values in the screens below were generated with the emulator for   illustration purposes and may not be very realistic).   LAI display   LAI readings are available only in this mode.   With Beam Fraction sensor   With no BFS   PAR display   This display is most often used for simple light interception measurements which   can later be processed to give values of the fractional interception.   All display   This mode is appropriate for PAR mapping and profiling. Each stored reading   contains the summary readings displayed, plus the 64 individual photodiode   readings. Don't use this mode unless you have to - it will consume data file memory   space much more rapidly!   In the All display on the Workabout, there is not enough room to display the   individual photodiode readings. You can only view these in the File, Review screen,   or after transferring the data file to your PC (but they can be viewed with a PC   connected directly to the SunScan probe instead of the Workabout).   46 • Measurement options   Document code: SS1-UM-1.05   The Autolog function   You can set up the SunScan system to operate automatically in any of its modes, just   as if you were pushing the read, store and average buttons at regular intervals.   Note: don't confuse Autolog with logging the probe as a Linear Quantum sensor, or   with logging the Beam Fraction sensor as an independent sensor. These applications   are dealt with in the Appendices.   From Menu, Utils, Autolog, Enter you will arrive in the Automatic Logging setup   screen:   This is the Autolog setup screen.   Use the ↑↓ keys to select the   choices; edit the prompted values   or use the ➙ keys to toggle   through options presented.   System time in the heading is   constantly updated   You will be prompted with a current   Start time, and 6 hours later Stop time   and date. Edit these appropriately.   Change the read interval to   whatever sampling interval you   want (hh:mm:ss).   Nighttime is defined as when the   sun is more than 6° below the   If you leave the Average interval at 0   horizon. SunScan computes this   you will not get average summaries.   for you automatically.   Any other setting (hh:mm:ss) will   insert average summaries into the data   file at the specified intervals.   The Start time can be set to a time up to 24 hours before the current time! You might   do this for example if you wanted to set up averaging on the hour with sampling at   one minute intervals but the system time had just gone past the hour.   When you are satisfied with your choices, press Enter to accept the screen and   initiate the logging process. After a few minutes the Workabout will sleep and the   screen will go blank. You can safely press Off to blank the screen immediately (it   will not stop the Autolog process). From time to time when a reading is logged, the   screen will briefly show a Logging in progress message.   At any time, if you want to check the status of the Autolog, press On/Esc to access   the screen on the left.   The timing of the next reading (and the Plot and Sample number) will be indicated,   with the current system time. You can either select Sleep, Enter (to continue) or   Cancel, Enter to cancel (stop) the logging session from this screen. If you select   Cancel you must confirm that you want to stop logging by pressing On/Esc.   SunScan User Manual v 1.05   Measurement options • 47   Battery and memory management   When leaving the SunScan probe to Autolog over a few days, the memory space on   the Flashcard will determine how long it can run for, provided the Workabout Ni-Cd   battery is fully charged, and the probe alkaline batteries are not near the end of their   life. Approximate indications of data memory requirements are given in the earlier   Data memory management section.   Warning! If you leave the Workabout in the field for Autologging, you must enclose   it in a bag or container with plenty of desiccant to protect it from the possibility of   internal condensation. If you are using the Beam Fraction sensor as well during the   Autolog process, bear in mind that the shade ring may need occasional   readjustment.   Measurement procedures in the field   Of course it is worth checking the equipment a day or two before your field   experiment for routine matters such as the state of the batteries and the internal   desiccant. See the Technical Reference section for details of these.   Probe handling in the field   Earlier sections in the SunScan User Manual (Measurement options and experiment   design) give you guidance as to what equipment you will need (BFS or not) and   what types of measurement you will make (LAI, PAR, or All). This section helps   with practical comments and advice.   The probe GO button   The red button on the probe handle allows you to initiate and store repetitive   readings from the probe without needing to look at the Workabout display. Listen for   the tones from the Workabout which tell you where you are in the process:   • single beep - initiate READ   • double beep - accept STORE   The GO button functions just like the Enter button on the Workabout, for all menu   options that are presented at the bottom of the screen.   Levelling the probe   The probe is fitted with a miniature bubble level to help you hold it level during the   measurements.   In most situations beneath the canopy, exact levelling of the probe is not critical.   Do your best to minimise your own shading of the probe when taking readings. If the   probe can "see" you, you will be blocking a certain amount of diffuse light from the   sky. Casting a dense shadow on the probe by blocking the direct beam could cause   significant errors.   Your best strategy will be to take as many samples as quickly as you can rather than   aim for perfection with each reading. This will counter the spatial variability of most   canopies, and is especially true if you have to work in unsteady light conditions.   When using the GO button, concentrate on getting the best levelling for the READ   function (single beep) which then "freezes" the reading. It does not matter whether   the probe is level when you press GO the second time to store the reading.   48 • Measurement options   Document code: SS1-UM-1.05   Levelling is most critical when you are using the probe:   • for the incident radiation above the canopy, and   • when then direct solar beam is strong, and   • when the sun is low in the sky.   Use of the tripod   The probe base has a standard camera mount socket for use with the tripod. You will   probably not want to use this routinely, but you could use it, for example, to mount   the probe in one fixed position for taking readings in the Autolog mode during the   course of a day.   The Workabout   Whatever measurements you are taking, you will always have the probe connected   via its coiled cable to your Workabout or other data collection device. The terminal   case and strap supplied with the Workabout should enable you to operate the   keyboard with one hand.   BFS handling in the field   The Beam Fraction sensor is definitely recommended for taking most types of   readings, however the extra cable connection to the SunScan probe does add an   unwelcome practical complication! If, in addition, you are using a portable PC   instead of the Workabout, you may find that a two-person team can cope much better   than a single person working alone.   Diffuse photodiode. In line with   the shade ring pivots   Bubble level.   Desiccant indicator   Total photodiode   Align this arrow with North   Using the tripod   The BFS has a tripod mount, which will probably be the most convenient mounting   method to use above low field canopies (up to about 1.8 m high). If you are working   with canopies higher than this, you will need to devise an alternative mounting   method.   SunScan User Manual v 1.05   Measurement options • 49   Finding North, and setting the shade ring   If you are taking measurements which require only the incident total radiation on   the canopy, you can ignore the compass orientation of the BFS and you should set   the shade ring horizontal so that it is not in use.   If, however, you want the Direct and Diffuse components of the incident radiation,   you must elevate the shade ring so that its shadow falls across the Diffuse sensor   (the one directly in line with the shade ring pivots), covering it completely.   If you are moving the BFS frequently, the compass orientation of the BFS need not   be accurately set to north. If you want the shadow to track correctly for longer   periods of time, set the BFS to point true north more carefully. The same instructions   apply if you are using the BFS in the southern hemisphere.   The shadow may not track perfectly throughout the course of a whole day, owing to   limitations imposed by the simple and robust design of the BFS. You should inspect   the BFS from time to time and readjust the ring if necessary.   In overcast conditions, the exact elevation of the shade ring is not critical (and it is   quite difficult to estimate!). If there is any chance of direct sun breaking through,   you must wait for it to do so before setting the elevation.   Levelling the BFS   The BFS is equipped with a miniature bubble level. The tripod supplied has 3-axis   adjustment to facilitate levelling.   It is more important to level the BFS accurately than the probe.   The usual routine for setting up the tripod will be:   • Orientate the BFS to face true north.   • Level the BFS.   • Elevate the shade ring to bring the shadow completely across the Diffuse sensor   (the northernmost one).   Extension cables, and the location of the BFS   Extension cables of 10, 25 and 50 m can be fitted between the BFS and the probe,   which will extend your range of operation from the BFS. There is a trade-off   between range and convenience: the greater your range, the fewer times you need to   re-site the BFS, but the more time you are likely to spend handling the cable.   Extension cables can be joined together. A combination of two shorter cables may   be preferable to one long one.   You should bear in mind that the SunScan will read the BFS and probe   simultaneously. If the different locations are widely spaced apart, the light levels   could momentarily be different - cloud shadows can easily travel at 20 m.s-1.   The solution is to be aware of this possibility in fast changing conditions and avoid   taking readings at critical moments.   Very long cable lengths may introduce a small systematic error in BFS readings. Up   to 100 metres, this should not be significant (< 10 µmol.m-2.s-1). At 200 metres it   could add about 20 µmol.m-2.s-1 to the readings, which may need subsequent   adjustment .   50 • Measurement options   Document code: SS1-UM-1.05   PAR calibrations   This section describes the basis for the light calibrations used in the SunScan   system, and explains when and how you might want to recalibrate the probe or   restore its factory calibration.   Factory light calibration   The SunScan probe and Beam Fraction Sensor are calibrated to give PAR readings   which match those of a standard PAR quantum sensor in typical bright daylight   conditions.   This matching cannot be made completely reproducible because an ideal PAR   quantum sensor has perfect spectral and cosine responses whereas the SunScan   probe and BFS can only approximate to the ideal. However, for most normal usage,   the SunScan calibration will be perfectly satisfactory, but if you are working under   strong artificial lights (for example) you may need to contact Delta-T for advice.   SunScan readings of LAI and fractional interception depend for their validity on the   ratio of the transmitted light to the incident light rather than their absolute values,   so it is the matching between the probe and the BFS calibration that is important.   Checking the probe/BFS matching   It is good experimental practice to carry out this test in the field before (and after)   taking a lot of readings.   ♦ Mount the SunScan probe and your BFS horizontally in uniform sunlight. Place   the shade ring horizontal as well. Make sure the probe and BFS diffusers are   clean.   ♦ In the SunData program, select the PAR display (∪+F hot key), and take some   readings.   The display will show you the values of the SunScan probe, BFS Total and BFS   Diffuse sensors. All three values should be approximately the same. Store these   readings, and you will have complete results that you can refer back to later if need   be.   The BFS values should be within about 5% of each other.   Mismatches of this magnitude have only a minor effect on the beam fraction   calculations and hence the LAI. (There is no field method for re-matching the Total   and Diffuse sensors. Contact Delta-T if you have a problem).   The probe and BFS Total readings may be within 5-10% of each other without   greatly contributing to errors in canopies where the transmission is below 50%.   Errors from the mismatch are likely to be swamped by the magnitude of the variation   in the samples. However, if you want to improve the matching, then proceed with the   Recalibrate option.   The Recalibrate option   This option matches your probe to your BFS (you cannot recalibrate the probe if you   do not have a BFS).   ♦ Set up the probe and BFS as for the previous test. On the Workabout, access the   Calibrate procedure (∪+C) and select Recalibrate SunScan, then follow the   instructions.   SunScan User Manual v 1.05   Measurement options • 51   You should not expect to have to do this very often. The photodiodes and light   measurement circuits are very stable.   The source of the apparent variability mentioned above is the not quite ideal cosine   and spectral response of the sensors.   Restoring the factory calibration   At any time after carrying out the Recalibrate option you can restore the original   factory calibration. You do not have to set up the probe or BFS in uniform light.   ♦ On the Workabout, simply access the Calibrate procedure (∪+C) and select   Restore Factory calibration.   You will briefly see a message confirming that this has been done.   Effect of the shade ring on the BFS   If the above matching tests are carried out with the shade ring elevated (but not   actually casting a shadow on either BFS sensor), you will get different results.   The shade ring blocks about 7% of the diffuse sky light, and none of the direct beam.   In bright sun conditions it will have no significant effect on LAI readings. In   completely overcast conditions it might contribute a small error of up to 0.1 to the   LAI value.   Comparing the calibration with other PAR sensors   You can carry out matching comparisons between the probe and BFS and any other   PAR quantum sensor. You cannot reset the probe values to it, but you can annotate   the readings and retain the comparison information in the SunScan data files.   Routine maintenance and cleaning   The probe diffuser is Perspex. Clean it when necessary with a damp cloth, moistened   with mild detergent, or with IPA (iso propyl alcohol).   The BFS diffusers are also made of Perspex. Clean them very carefully, especially   the groove around the diffusers. Use a fine soft brush to remove any dirt or dust   from the groove - it could affect the accuracy of the cosine response of the sensors.   The "spread" measurement   The "spread" value is a measure of the relative variation of the light along the probe.   This is a useful parameter in light profiling measurements: it is the value of the   standard deviation of the 64 photodiode readings, divided by their mean.   You can check the probe uniformity of calibration at any time by taking a reading in   uniform light. The spread value should be 0.00 or 0.01.   52 • Measurement options   Document code: SS1-UM-1.05   Environmental and moisture protection   You should be aware of the different levels of protection of the components of the   SunScan system to avoid putting them at risk when working outdoors. As with all   field instruments you should minimise, as far as practical their exposure to high or   rapidly changing temperatures.   The SunScan probe and Beam Fraction Sensor   Warning! The probe and BFS are designed to resist dust and water jets (IP65), but   they are not hermetically sealed. They will survive rainfall, but will not survive   being immersed in water.   Avoid any situation where they could be flooded. Internal condensation will be   avoided provided that you keep the desiccant fresh. Inspect the coloured indicator   panels on the housings to check this.   The probe and BFS are reasonably robust, but they do not have a drop test rating. Do   not drop them! Take extra care when carrying the 1 metre-long probe!   The Workabout   The Workabout is dust proof and splash proof (IP54), and has a 1 metre drop test   rating, but does not contain desiccant. Operating conditions are specified as 0% -   90% RH, non condensing.   Warning! If you leave the Workabout in the field for Autologging, you must enclose   it in a bag or container with plenty of desiccant to protect it from the possibility of   internal condensation.   SunScan User Manual v 1.05   Measurement options • 53   LAI theory   In this section we shall explain as fully as we can how the SunScan computes its   readings of leaf area index, and what the main limitations and provisos are in   interpreting these for real canopies.   Ingredients of the LAI computation method   There are three broad areas contributing to the final result.   Geometric analysis   The first is the analysis of what happens to a ray of light passing through the canopy.   In order to do this, we have to make some general assumptions about the canopy, i.e.   uniformity, randomness and total absorption by canopy elements. This was done by   Campbell (1986) for a beam of light from a single direction (the Direct solar beam)   passing through a canopy with a generalised ellipsoidal leaf angle distribution   function. This function allows a wide range of different canopy types to be described   by the value of a single parameter ELADP.   Wood then integrated Campbell’s result over the whole sky to give a description of   the transmission of Diffuse light through the same canopy. This is important because   the transmission of Diffuse light is different, and in reality there is usually a   combination of both Direct and Diffuse illumination. In particular, the analysis   shows that Diffuse transmission is strongly dependent on the leaf angle distribution,   a point which has not generally been recognised.   These functions are integrals which do not have direct analytical solutions, so have   to be solved numerically, and computable functions fitted to the results. This has   been done to a high degree of accuracy, improving on Campbell’s original   approximation.   Incomplete absorption - more elaborate analysis   The above analysis based on black leaves is relatively straightforward. However,   real leaves also reflect or scatter some of the light that falls on them. Typically, only   about 85% of the incident light is absorbed. This means that in reality, every leaf   element in the canopy is re-emitting light, as well as absorbing it, which makes the   situation much more complicated.   Because the direction of any particular light ray can be changed by reflection or   scattering, it means the spatial distribution of the light changes through the canopy.   Therefore it is no longer adequate to consider just the vertical component of the light   (as measured by a cosine corrected sensor), the horizontal component must also be   included. This is why Wood’s analysis also considers a hemispherical response   sensor (which measures both horizontal and vertical components).   The relentless advance of computing power has made it possible to model the   situation in ways that were not feasible in the past. By integrating the "black leaf"   analysis into a computer model Wood has calculated the light levels in the canopy   across the whole range of canopy and incident light parameters.   54 • LAI theory   Document code: SS1-UM-1.05   Equation fitting and inversion   The results of the computer modelling, while accurate, are not suitable for use in a   field instrument. It takes many minutes of processing on a fast PC to calculate light   transmission for any given conditions using the model, and the Psion Workabout is   not a fast computer!. The model calculates values of light transmission for a given   LAI, whereas the SunScan measures light transmission. This means that the   functions have to be inverted to work back to LAI, which is more difficult.   To give you immediate results in the field, computable functions have been fitted to   the model data, and it is these that are solved to give LAI to reasonable accuracy   from the parameters measured by the SunScan system.   Note! Wood’s SunScan equations are copyright, and you should not copy them   without written permission unless for purposes of scientific debate or publication, in   which case they should be fully acknowledged.   Theory versus reality   We believe that Wood’s SunScan equations accurately reflect the assumptions that   the modelling is based on.   By far the largest uncertainties are bound to be caused by   • the mismatch between the real canopy architecture and the simplifying   assumptions built into the fundamental analysis   • to a lesser extent the uncertainty in the numerical values of ELADP estimated for   your canopy.   With these caveats, the values of LAI for your canopy, even if of uncertain accuracy,   will provide valid trends for a given canopy (e.g. canopy growth in a season), and   valid comparisons between different canopies of similar architecture (e.g. trial plots   of different cultivars of the same species). If you are able to compare SunScan   estimates with actual harvested samples from time to time, this will enable you to   calibrate out any systematic errors due to your canopy not matching the SunScan   assumptions.   If you wish, you can force the SunScan calculations to be equivalent to older, less   sophisticated inversions by setting some of the parameters to appropriate values.   For example, setting ELADP to 1024 (horizontal leaves) and Absorption to 1.0 will   give you the simple Beer’s law inversion.   Derivation of Wood’s SunScan canopy analysis equations   The major assumptions   • The canopy is an infinite, uniform, horizontal slab, with leaf elements randomly   distributed in proportion to the surface area of an ellipsoid, as described by   Campbell.   • The incident light consists of a component from a point source at a given zenith   angle (the Direct beam); and a Diffuse component of equal intensity from every   point in the sky (Uniform Overcast Sky).   • The canopy either has sufficiently high LAI that light reflected back from the   ground below is negligible, or the reflectance of the ground is similar to that of   the canopy.   • Of the light intercepted by the leaf element, a fraction a (absorption) is totally   absorbed. The remainder is re-emitted uniformly in all directions.   SunScan User Manual v 1.05   LAI theory • 55   Beer's law for canopy absorption   Beer's law occurs in many situations where events happen at random. In the case of   light absorption by a canopy, it applies to the absorption of incident photons or light   rays. For a uniform infinite randomly distributed canopy of completely absorbing   leaves, it can be shown that the relationship between the transmitted light I, a beam   of incident light I0 and the Leaf Area Index L is given by:   . . I I exp( K L)   0 where K is the extinction coefficient which depends on the leaf angle distribution   and the direction of the beam. K=1 for entirely horizontal leaves.   Campbell's Ellipsoidal LAD equations.   Campbell (1986) derives an equation for the extinction coefficient of leaves   distributed in the same proportions and orientation as the surface of an ellipsoid of   revolution, symmetrical about a vertical axis. The semi vertical axis is a and the semi   horizontal axis is b . There is symmetry about the vertical axis. He relates these to a   single parameter x = b/a. (x is the Ellipsoidal Leaf Angle Distribution Parameter, or   ELADP). The extinction coefficient also depends on the zenith angle of the   incoming direct beam. Canopy elements are assumed to be completely black, and   randomly distributed in a horizontal slab extending to infinity in all directions.   Note: in the following equations derived in MathCad, different conventions are used   for some symbols. Equality is represented by :=, and tan2 (θ) is expressed tan(θ)2 .   The extinction coefficient, K, is calculated as follows:   2 x2 tan(   . θ ) Ext'n   Coeff't   3 2 1 0 K( x ,   θ ) 0.708   x 1.702 ( x 1.12)   K( 0,   K( 1,   θ θ ) ) Where:   x is the ELADP   θ is the zenith angle of the direct   beam.   K( 100 ,   θ ) The transmitted fraction of incident   0°   90°   θ direct light is given by:   . τ exp( K( x ,   θ ) L)   dir   where L is the canopy LAI.   Transmission of Diffuse Light   Campbell's analysis applies only to a beam of light from a specific direction, which   is the Direct solar beam in our case. Even under strong sunlight, the Direct fraction   rarely exceeds 80% of the Total incident radiation, so penetration of the Diffuse   component of incident radiation is also important.   There is a misconception that the extinction coefficient for Diffuse light is   independent of canopy Leaf Angle Distribution, but this is not the case as the   following analysis shows. As the following graph also shows, transmission of   Diffuse light does not obey a simple Beer's law curve, so cannot be represented by a   single extinction coefficient, except in the case of a horizontal LAD.   56 • LAI theory   Document code: SS1-UM-1.05   The next section derives the transmission of light from a uniform overcast sky   through a uniform infinite canopy of black leaves of constant LAI with an ellipsoidal   leaf angle distribution.   Let the sky have uniform brightness of 1 per steradian over the hemisphere.   The radiance of a strip around the sky at angle θ is given by:   .π .   . R 2 sin(   θ ) dθ   and the irradiance on a horizontal surface due to that strip is given by   .π .   . . I 2 sin(   θ ) cos( ) dθ   θ 0 The total irradiance due to the hemisphere is obtained by integrating over the   complete sky area:   π 2 .π .   . 2 sin(   θ ) cos(   θ ) dθ   = 1   π 0 For each strip of sky, the transmitted radiation is given by   . . I I exp( K L)   0 where K is the extinction coefficient from Campbell,   so the total transmitted radiation is   π 2 .π .   . . . I 2 sin(   θ ) cos(   θ ) exp( K( x , ) L) dθ   θ 0 and the transmission fraction τ is given by I/I0   π 2 1 . .π .   . . . τ ( x , L)   diff   2 sin(   θ ) cos(   θ ) exp( K( x , ) L) dθ   θ π 0 This integral was evaluated numerically over the range x = 0 to 1000 and L = 0 to   10, and is graphed below for three different values of x.   SunScan User Manual v 1.05   LAI theory • 57   Diffuse light transmission (cosine corrected sensor)   1 Transmission   fraction   Leaf Angle Distribution   vertical   0.1   τ τ τ (0,L)   diff   diff   diff   vertical   (1,L)   spherical   horizontal   spherical   (1000 ,L)   0.01   horizontal   0.001   0 2 4 6 8 10   L Leaf Area Index   Modelling the canopy transmission   Accounting for incomplete absorption of PAR by the canopy elements, and   scattering of light within the canopy is complicated. It is no longer sufficient to   consider only the vertical component of PAR (i.e. as measured by a cosine-corrected   sensor) because scattering effectively transfers power between the horizontal and   vertical components, so the canopy changes the spatial distribution of power in the   PAR flux as it is transmitted down through the canopy and reflected back up.   A multi-stream computer model was set up to calculate these effects as follows.   Assumptions   • The canopy is an infinite, uniform, horizontal slab, with leaf elements randomly   distributed in proportion to the surface area of an ellipsoid, as described by   Campbell.   • The incident light consists of a component from a point source at a given zenith   angle (the Direct Beam); and a Diffuse component of equal intensity from every   point in the sky (Uniform Overcast Sky).   • The canopy either has sufficiently high LAI that light reflected back from the   ground below is negligible, or the reflectance of the ground is similar to that of   the canopy.   • Of the light intercepted by the leaf element, a fraction a (absorption) is totally   absorbed. The remainder is re-emitted uniformly in all directions.   58 • LAI theory   Document code: SS1-UM-1.05   In detail:   • The canopy is divided into horizontal layers of LAI 0.1   • Direct beam absorption by each layer is calculated using Campbell's equation. In   calculating the amount of absorbed light that is re-emitted, the total power in the   direct beam has to be used (i.e. as measured by an integrating hemisphere or a   cosine-corrected sensor perpendicular to the beam). The amount intercepted by   the layer is the difference between the absolute intensity above and below the   layer.   • Diffuse light intercepted by the layer is calculated in a similar way, taking into   account the incident Diffuse light, and the sum of re-emitted light from all other   layers, attenuated by the intervening layers. This is done for both downwelling   and upwelling Diffuse light. A fraction of the Diffuse light absorbed by the layer   is also re-emitted. Again, absolute rather than cosine-corrected intensity   measurements must be used.   • Both cosine-corrected and absolute light measurements are calculated for each   layer, and the model iterated until it converges. This has been done for a range of   different values of zenith angle, Direct/Diffuse ratios, Leaf Angle Distributions   and Absorptions.   Simpler functions have been found to approximate these results, and are used in the   SunData software when inverting transmitted fraction back to LAI. These are   described in detail in the next section.   The canopy model   SunScan User Manual v 1.05   LAI theory • 59   Accuracy of LAI calculations   When used to predict LAI from transmitted fraction, the functions used in the   SunData software are accurate to within ±10% ±0.1 over the range of LAI less than   10 and Zenith Angle less than 60° when compared to the output of the full model.   The errors become larger for highly vertical leaves with a strong low sun, and users   should avoid these conditions if possible.   In practice, the greatest errors are likely to follow from the differences between the   real canopy and the idealised assumptions in the model.   Functions used to model canopy transmission   Diffuse light - cosine response sensor   The transmission of diffuse light through a canopy, as measured by a cosine   corrected sensor, can be modelled by the following functions:   1 Given:   A( x )   1.38   . 0.15 x   0.007   . . B( x )   C( x )   4.32 2.60 exp( 2.75 x )   . . 0.57 0.23 exp( 1.40 x )   3 C( x)   . . . τ ( x , L)   diff   exp( L) A( x ) L exp B( x ) L   These curves give maximum errors of 0.009 in τdiff, with a maximum 6% error for   τdiff greater than 0.01 over the range L = 0 to 10 and x = 0 to 1000.   Diffuse light - hemispherical response sensor.   The previous analysis of diffuse light transmission is appropriate for a cosine-   corrected sensor as it only considers the vertical component of the incident and   transmitted light. This works as long as the leaf absorption in the PAR band is   complete, and there is no scattering of the incoming light.   When we consider leaves with incomplete PAR absorption, some of the absorbed   light is re-emitted in different directions to the original incoming light. Because of   this we have to account for all of the incoming light, both horizontal and vertical   components, and also be aware that the spatial intensity distribution of the light is   modified by the canopy and varies through the canopy depending on the canopy leaf   angle distribution.   The above analysis is now repeated to find the transmission of uniform diffuse light   as measured by a sensor with a hemispherical response. The equivalent equation for   the transmission fraction is:   π 2 1 . .π .   . . τ ( x , L)   2 sin(   θ ) exp( K( x , ) L) dθ   θ spher   . 2 π 0 60 • LAI theory   Document code: SS1-UM-1.05   This was again calculated numerically and curves fitted to the data with similar   accuracy as above. The curves fitted are:   . . . . P( x )   Q( x )   R( x )   1 0.4 exp( 0.1 x ) ( atan( 0.9 x ) 0.95)   Given:   . 0.255 atan( x ) 0.6   exp( x )   exp P( x ) LQ(x) R( x ) ln( 1 L)   . . τ ( x , L)   spher   Diffuse light transmission (hemispherical response sensor)   1 Transmission   fraction   Leaf Angle   Distribution   Vertical   0.1   τ τ τ (0,L)   spher   Vertical   (1,L)   spher   spher   Spherical   Horizontal   (1000 ,L)   Spherical   0.01   Horizontal   L 0.001   0 2 4 6 8 10   Leaf Area Index   Modelling incomplete PAR absorption and scattering   Radiation models have been used for many years to calculate the effects of scattering   in the canopy e.g. Norman & Jarvis (1975). Wood's model incorporates Campbell’s   ellipsoidal leaf angle distribution and the effects this has on transmission of both   Direct and Diffuse light.   The model splits the canopy into layers of LAI 0.1, extending to a sufficient depth to   absorb all of the incident light. Incident light above the top layer was a known   fraction of Direct (at a given zenith angle) and Diffuse light. The amount of light   absorbed by a layer, assuming completely black leaves, was calculated. The fraction   of this absorbed light re-emitted by the leaves was then assumed to be re-emitted in   all directions uniformly (see Monteith & Unsworth, 1990, p85 onwards) .   The light level at any point in the canopy is then the light calculated assuming   complete absorption, plus the sum of the light re-emitted by each canopy layer,   attenuated by the intervening layers.   These calculations had to take full account of both horizontal and vertical light   components. This involved an iterative solution and a lot of computer time. Finally,   the light intensity as measured by a cosine corrected sensor was calculated.   SunScan User Manual v 1.05   LAI theory • 61   The results were then analysed in terms of La, the LAI of a canopy of black leaves   that would give the same transmission as a canopy of LAI L assuming incomplete   absorption, all other factors being equal.   . L L ( 1 g( 1 a) )   a L is the "true" LAI, La is the LAI that when used in the black leaf model, gives the   same transmission as L used in the complete model. a is the leaf absorptivity in the   PAR band.   The function g varied with all the other parameters in a complex way, but most   strongly with x, the leaf angle distribution parameter, and with solar zenith angle for   the direct beam. The following equations represent quite a crude approximation to   the full model, but give satisfactory results for most situations. If any given   transmission fraction is inverted using the approximation, the LAI calculated is   within ±10% ±0.1 of the "true" LAI indicated by the full model, except for x near 0   (extreme vertical leaves) and zenith angle > 60 ° (strong low sun).   g 0.5   For diffuse light:   diff   2 5 . . . . For direct beam:   g exp( 1.5 x )   0.2 0.7 zen   0.2 zen   0.3   dir   where: x is the ellipsoidal leaf angle distribution parameter   zen is the solar zenith angle in radians.   The full equation thus becomes:   . . . . τ f exp K( x ,   θ ) 1 g ( 1 a) L ...   Direct part   Diffuse   b dir   3 C( x)   a . . . . + 1   f exp   L A( x ) L   exp B( x ) L   b a a This looks hard to invert to get LAI from τ, but an iterative solution is fairly   straightforward given the computing power, and is much simpler than the full   numerical solution.   Calculating zenith angles   Zenith angles are calculated from latitude, longitude, and local time using standard   astronomical equations as given in Practical Astronomy. These give zenith angles   accurate to better than 0.1° and times of sunrise or sunset to within a few seconds.   Summary   A computer model has been created which calculates accurately the transmitted light   below the canopy based on the assumptions given. This has been run over the whole   range of each of the different variables, i.e. Direct beam angle, Direct beam fraction,   Leaf Angle Distribution, Leaf Absorption and Leaf Area Index. The results of these   runs, taking many hours of computer time, have been collected and functions found   to fit them.   These approximating functions are used in the SunData software to predict LAI from   the measured inputs in the field. The LAI values calculated by the SunData software   are within ± 10% ± 0.1 of the LAI that would have been calculated by the full   model.   Scientific references   Campbell G S (1986). Extinction coefficients for radiation in plant canopies using   an ellipsoidal inclination angle distribution. Agric. For. Meteor., 36:317-321.   62 • LAI theory   Document code: SS1-UM-1.05   Daughty, Craig S T (1990). Direct measurements of canopy structure. Remote   Sensing Reviews 1990 vol 5(1) pp 45 - 60.   Diffey B L (ed).(1989) Radiation Measurement in Photobiology. Academic Press.   Goudriaan J (1977). Crop Micrometeorology: A Simulation Study. Centre for   Agricultural Publication Documentation, Wageningen, Netherlands.   Jones, Hamlyn G. (1992) Plants and Microclimate second edition. CUP.   Lang A R G & Xiang Yueqin (1986). Estimation of leaf area index from   transmission of direct sunlight in discontinuous canopies. Agric. For. Meteor.   35:83-101.   Lang A R G, Xiang Yueqin, & Norman J M (1985). Crop structure and the   penetration of direct sunlight. Agric. For. Meteorol. 35:83-101.   Marshall B and Woodward F I (eds). (1985) Instrumentation for Environmental   Physiology. SEB Seminar series 22, CUP.   Monteith J L & Unsworth M H. (1990) Principles of Environmental Physics second   edition. Edward Arnold (Hodder & Stoughton).   Norman J M & Welles J M (1983). Radiative transfer in an array of canopies.   Agron. J. 63:743-748.   Norman J M and Jarvis P G (1975). Photosynthesis in Sitca Spruce (Picea sitchensis   (Bong) Carr.) V. Radiation penetration theory and a test case. J. Appl. Ecol.,   12:839-878   Russel G, Marshall B and Jarvis P (eds). (1989) Plant Canopies, their Growth, Form   & Function. SEB Seminar series 31, CUP, Cambridge   Wang Y P and Jarvis P G (1988). Mean leaf angles for the ellipsoidal inclination   angle distribution. Agric. For. Meteor., 43:319-321.   Welles J M (1990). Some indirect methods of estimating canopy structure. Remote   Sensing Reviews 1990 vol 5(1) pp 31 - 43.   SunScan User Manual v 1.05   LAI theory • 63   Technical Reference section   Maintenance and repair   Checking the batteries   The SunScan system requires batteries within the probe and in the Workabout. The   Beam Fraction sensor does not require batteries because it draws its power from the   probe.   The SunScan probe batteries   The probe is powered by 4 AA size alkaline cells mounted within the probe handle.   With typical use, these batteries should last from 6 - 12 months. The probe circuit   automatically "sleeps" when no readings are being taken. There is no probe on/off   switch.   Checking the probe battery level   Connect the probe to the Workabout, and from the SunData program take a reading   with the probe (any light reading will do - it is required only to activate the battery   sensing circuit).   Then press ∪+B (or Menu,Utils,About). The screen display will show various   version numbers plus a Battery mV reading.   Replace the batteries if the reading is 4700 mV or less. A reading of 5000 mV or   above indicates that the batteries are healthy. You will get an on-screen warning if   the batteries are low. When this happens replace them as soon as you can.   If you get a 0 mV reading, the probe has not been read. Take a light reading, and try   ∪+B again.   Probe battery life   With a fresh set of batteries in the probe, you could take about 300,000 readings. If   you took no readings, the batteries would last for about 6-12 months.   Warning! If you are likely to store the probe for a long period, you should remove   the batteries.   Replacing the probe batteries   You must dismantle the probe handle. Disconnect the BFS and the probe's RS232   cable. The baseplate of the probe is secured to the handle by 4 cross-head corner   screws. Unscrew these to remove the handle, whilst carefully supporting the probe.   The battery holder can now be prised out of its compartment, and the batteries   changed.   The Workabout batteries   Checking the Workabout battery levels   The Workabout is supplied with a rechargeable Ni-Cd battery pack and a Lithium   back-up battery installed. Press Shift+Ctrl+B to display the Psion Battery info   screen. You will be warned when the batteries get low. Switch off and recharge the   batteries as soon as possible.   For full details on the care and maintenance of the Workabout's batteries you should   refer to the Workabout User Guide pages 2-5, but the following brief notes will get   you started.   64 • Technical Reference section   Document code: SS1-UM-1.05   Workabout battery management   When you receive the Workabout, the installed battery pack may not be fully   charged. Connect the Workabout to the Docking unit and Charger immediately, so   that charging can proceed whilst you are learning to use the SunScan.   The charger is a trickle-charger and may take 14 hours to fully recharge the battery   pack. A fully charged Ni-Cd battery should easily give 2 or 3 full days use in the   field. You must then recharge the Workabout overnight if you want to continue with   daily use in the field.   Warning! In general, Ni-Cd batteries prefer to be fully discharged before being   recharged. Do not leave them continuously trickle-charging.   If you ordered a spare Ni-Cd battery pack it will not be charged initially. Charge it as   soon as you have the opportunity, so that you can replace an exhausted one without   delay.   To gain access to the batteries, open the battery drawer by pressing the black button   at the top left corner of the Workabout very firmly.   The Workabout will run equally well from 2 AA alkaline cells. Carry some of these   with you if there is any chance that your Ni-Cd will become exhausted when no   mains power is available for recharging.   Warning! Don't leave the Workabout without a main battery for more than a day or   two. Its back-up cell will last for several days only.   Beyond this time you may lose data in the internal memory (but Flashcard data will   not be affected).   If you get low battery warnings, even after fully charging the Ni-Cd pack, these can   be reset by removing and then replacing the pack.   Checking the desiccant   Both the SunScan probe and Beam Fraction sensor contain desiccant packs to   prevent internal condensation of moisture when they are used outside. The dryness   of the desiccant is indicated by a coloured panel on the outside of each housing. Blue   indicates dry, pink indicates that renewal is needed. The Workabout does not contain   desiccant.   Refreshing the desiccant   The desiccant pack can be regenerated by heating. Remove the pack from the probe   or BFS and heat the pack in an oven for a few hours at about 140ºC, then allow it to   cool down away from moisture before reinstalling it.   Access to the probe handle is as described above for probe battery changing. To   access the Beam Fraction sensor, prise upwards the red plastic strips on the lid, then   undo the four cross-head screws that are revealed.   SunScan User Manual v 1.05   Technical Reference section • 65   Checking the PAR calibration   Various techniques for checking the SunScan system PAR calibration and   consistency are described in the Measurement Options, PAR calibration section,   which you should refer to. This also includes advice on when to use the recalibrate   and restore factory calibration procedures.   Factory calibration method   A standard PAR Quantum sensor provides the reference value of PAR that the Beam   Fraction sensor and the SunScan probe are set up to. This process is carried out   under a near-daylight spectrum lamp in controlled conditions.   Re-setting the factory calibration   The electronic components and photodiodes used in the PAR circuits of the Beam   Fraction sensor and SunScan probe are very stable and are not expected to change   for the lifetime of the instrument.   Circuit adjustment facilities in the Beam Fraction sensor are provided for the initial   factory set-up and are not intended to be used for routine adjustment thereafter. The   probe factory calibration cannot be adjusted without specialist equipment.   Warning! Do not attempt to change the factory calibration without referring back to   Delta-T first. The most likely cause of an apparent change of calibration is physical:   dirt in the grooves around the BFS diffusers, or dirt or staining of the probe diffuser.   If after checking the above you still have:   • a Beam Fraction sensor with badly matched Total and Diffuse outputs, or   • a SunScan probe with an out-of-spec calibration, or individual diode readings that   appear faulty,   please refer back to your agent or the factory.   66 • Technical Reference section   Document code: SS1-UM-1.05   Troubleshooting   Psion Workabout   There is no SunData Icon in the system screen.   • From the Psion system screen, select Menu, Apps, Install, Enter, Tab, and select   Sundata.app in the \SUN\ subdirectory. If this file does not exist, it must be   copied from the SunScan program disk - refer to the appendix: File Transfer   between Workabout and PC.   The system fails to recognise a Flashcard in the A: or B: drives.   • Make sure the SSD drawer is firmly closed.   The Workabout gives continuous “low battery” warnings, even after fully recharging   the battery pack.   • Remove and then replace the battery pack when it is fully charged. This will reset   the “low battery” warnings.   Problems running the SunData application.   SunData fails to run, with exit code 80.   • The supporting file Sys$8087.ldd is not in the \SUN\ subdirectory. Copy it there   from the SunScan program disk - refer to the installation notes.   SunData reports “serial port in use”.   • Exit the program, and make sure the Remote Link is off. Press Menu, Spec,   Remote Link, Enter, from the system screen.   SunData fails with “insufficient memory” or “insufficient system resources” message.   • Close any other applications that are running. Delete any unnecessary data files   stored on the Internal drive. From the system screen, select Menu, Info, Memory   Info, Enter. If the amount of System memory is shown as more than 80k, reboot   the Workabout (∪+Ctrl+Del) and reinstall the SunData Icon. As a last resort, cold   boot the Workabout (∪+Shift+Ctrl+Del). You will then have to reinstall the   SunData programs from the SunScan program disk - see the complete installation   instructions.   While running SunData   SunData reports “SunScan probe not connected”.   • Check the cable connections. Check the condition of the batteries in the SunScan   probe.   SunData recognises the SunScan probe, but fails to take readings.   • Exit the SunData program, and run it again. If “BFS” is selected as the external   sensor in Menu, Settings, SunScan Probe, Enter, make sure a Beam Fraction   sensor is connected and is exposed to some light.   On running SunData, all the system settings are scrambled.   • The Default.cfg may be corrupted. Exit SunData and delete the file Default.cfg   in the \SUN\ subdirectory.   “Out of memory” reported on drive A:.   • Replace the Flashcard with an empty formatted one and start a new data file.   Transfer the data on the full Flashcard to a PC and reformat it.   SunScan User Manual v 1.05   Technical Reference section • 67   “Insufficient power to write data” reported.   • Recharge the Ni-Cd battery pack, or replace it with a freshly charged Ni-Cd pack   or two AA Alkaline cells.   When transferring files to a PC, data is transferred, but there are repeated checksum or   device IO errors.   • Reboot your PC and start again. See the advice on RS232 communications in the   SunScan Tutorial (p28).   SunScan or BFS give inconsistent light readings.   • Make sure the diffusers are clean and that the desiccant condition indicators are   blue. See the advice on PAR calibration in Measurement Options (p49).   68 • Technical Reference section   Document code: SS1-UM-1.05   Technical Support   Distributor contact   If you have a problem, please call your local distributor first.   Direct Delta-T contact   You can contact SunScan Technical Support at Delta-T directly on:   Tel: +44 (0)1638 742922   Fax: +44 (0)1638 743155   Email: [email protected]   Guarantee   The SunScan system and its components are guaranteed for one year against defects   in manufacture and materials. The guarantee does not cover damage through misuse   or inexpert servicing, or other circumstances beyond our control.   Problem Reports   It will help considerably if you can first fax through as many relevant details as   possible. In particular:   • a description of the fault, its symptoms, or error messages   • what components of the SunScan system you are using   • details of any PC you are using   • software version numbers and hardware serial numbers (see below)   SunScan circuit schematics and data   These are provided in a separate booklet: the SunScan Technical Manual.   Locating version and serial numbers   S/W Diskette:   SunData s/w type SDA1 has the version number on the label.   SunData S/W programs:   In the Workabout, from the SunData program: Menu, Utils, About, Enter   In your PC, from the SunData program: Alt+Utilities, About, Enter   SunScan probe   The serial number label is on the base of the probe handle.   The PROM chip (inside the probe handle) is labelled with its version number. This   can also be seen at the top of the SunData's title screen when the probe is connected.   Beam Fraction Sensor   The serial number label is on the underside of the case.   Psion Workabout:   Serial number is inside its case, at the top of the battery drawer.   SunScan User Manual v 1.05   Technical Reference section • 69   Specifications   SunScan Probe type SS1   Active area   1000 x 13 mm wide. Sensor spacing 15.6 mm.   Spectral response   Measurement time   Maximum reading   Resolution   400 - 700 nm (PAR)   120 ms   2500 µmol.m-2.s-1   0.3 µmol.m-2.s-1   Linearity   better than 1%   Accuracy   +/- 10%   1 mV per µmol.m-2.s-1   Analogue output   Serial interface   Environmental   Size (overall)   Power   RS232, 9 pin female 'D' connector   protected to IP65, 0° - 60°C working temperature   1300(l) x 100(w) x 130(h) mm   4 x AA Alkaline cells (lifetime up to 1 year)   Beam Fraction Sensor type BF1   Total PAR, Diffuse PAR. 1 mV per µmol.m-2.s-1   Outputs   2500 µmol.m-2.s-1   Maximum range   Cable length   Extension cables   Mounting   7 m standard   10 m, 25 m, 50 m   1/4 inch Whitworth tripod socket   protected to IP65, 0°...60°C working temperature   160 x 80 x 65 mm (excluding shade ring)   Provided from SunScan (5 - 12 V)   Environmental   Size   Power   Data Collection Terminal type DCT1 (Psion Workabout)   Full specifications for the Workabout are contained in its User Guide, app B p277.   Screen / keyboard   Data storage   Display options   Environmental   Drop resistance   Power   10 lines x 40 characters / full alphanumeric   Flashcards, 256k or 1Mb - effectively unlimited   a) LAI b) PAR average c) ALL individual sensor readings   IP 54, RH 0%...90% non condensing, -20°...60°C   1 m onto concrete   Ni-Cd pack (up to 15 hours per charge) or 2 x AA Alkaline cells   PC as Data Collection device   Alternatively, the SunScan probe can be operated directly from a PC, minimum   requirements:   • MS-DOS 3.3, and higher   • 512k RAM   • 80 x 25 character display   • RS232 port   • 3.5" FDD   70 • Technical Reference section   Document code: SS1-UM-1.05   Carrying Case type SCC1   Moulded plastic case with O-ring seal for moisture and dust proofing, including   pressure release valve.   Outside dimensions   Weight   1.40 x 0.44 x 0.16 m   approx 8 kg   Telescopic Tripod type BFT1   3-way head with quick release platform. Geared friction elevator control. Locking   leg catches and brace. Dual Spike/rubber feet.   Max. height   Closed length   Weight   1.73 m   0.68 m   2.5 kg   Spares Kit type SPS1   A detailed list of parts can be supplied on request. The kit includes:   • electrical components which might be subject to breakdown by electrostatic   discharge   • mechanical parts likely to break, be damaged or lost through wear and tear.   Logging Cables   Logger cable for SunScan probe, type SSDL10   10 m cable with connector to attach to SunScan probe, for logging as a linear   quantum sensor.   Logger cable for Beam Fraction sensor type BFDL5   5 m cable with connector to attach to Beam Fraction sensor, for logging Total PAR   and Diffuse PAR outputs.   SunScan User Manual v 1.05   Technical Reference section • 71   PAR Performance   The graphs below show the actual spectral and cosine response curves for the   SunScan system.   Spectral response   The spectral response curve shows that the SunScan response is almost entirely   within the PAR wavelength band of 400 nm - 700 nm. The GaAsP sensors used have   an increased sensitivity towards the red end of the spectrum, but this is compensated   for by the sharp cut-off at 670 nm. In practice, we have found that these sensors read   to within a few percent of an accurate PAR sensor in natural daylight conditions   above or within the canopy. However, if you are working under artificial or strongly   coloured light you should check the SunScan readings against an accurate PAR   sensor if you need to know absolute PAR levels.   SunScan   Spectral response   Ideal   160   140   120   100   80   60   40   20   0 350   400   450   500   550   600   650   700   750   wavelength nm   72 • Technical Reference section   Document code: SS1-UM-1.05   Cosine responses of probe and BFS   The cosine response curves show a diminishing response compared to the ideal at   high zenith angles. For this reason, you should avoid taking measurements when the   sun is strong and near the horizon.   Most studies will be looking at the ratio of incident and transmitted light, and the   graph shows the SunScan and Beam Fraction sensor are very closely matched in   their cosine and spectral responses, so the small deviations from the ideal will not   introduce significant errors.   Ideal   SunScan system cosine response   Actual   Actual / Ideal   1.1   1 0.9   0.8   0.7   0.6   0.5   0.4   0.3   0.2   0.1   0 0 10 20 30 40 50 60 70 80 90   0 10 20 30 40 50 60 70 80 90   SunScan probe Zenith angle °   Beam Fraction sensor   SunScan User Manual v 1.05   Technical Reference section • 73   Appendices   A. Logging the probe as a Linear Quantum Sensor   This application of the SunScan probe turns it into a simple Line Quantum sensor   that can be attached to a data logger. No Data Collection Terminal is used, but you   do require a data logger that can supply power to the probe when taking readings.   The Delta-T DL2e and DL3000 loggers are suitable for this purpose.   If you want to mount the probe on a tripod, a camera mount is provided in the base   of the probe handle. The probe's coiled RS232 cable is not used, and it must be   protected from moisture by enclosing it in a bag with desiccant, for example.   Note: no batteries are required in the probe for this mode, but it does not hurt to   leave them in situ.   Wiring connections   You must use the (optional) special logging cable which plugs into the socket on the   probe handle normally occupied by the Beam Fraction sensor. The cable is 10 metres   long. If you need more length, simply join on extra screened multicore cable of a   similar type. Make sure the joint is weatherproof.   The cores of the probe logging cable have the following functionality:   Core   orange   green   brown   grey   Function   Logger Connection   V+ Power supply positive   0V Power supply negative   HI Signal output positive   LO Signal output negative   not used   Sensor power positive (switched for warm-up)   Sensor power negative (0V)   Input channel +   Input channel -   blue   braid   Screen   Not connected (see below)   Note: the grey, green and braid are connected internally in the probe handle.   Connecting the braid to an earthing point on the logger could create earth loops, and   is not recommended.   Output   • The output signal is the transmitted PAR irradiance, averaged along the length of   the probe. (Individual photodiode readings are not accessible in the Linear   Quantum Sensor mode.)   • The millivolt output is linear, with a sensitivity of 1 mV = 1 µmol.m-2.s-1.   Maximum output is 2500 mV.   Logger requirements   • The probe requires a voltage supply of 7-15 V dc (unregulated), at about 30 mA   current. The analogue output is enabled when the external voltage is greater than   the battery voltage.   • Configure one channel of the logger for voltage input, with the above sensitivity.   • Use a "warm-up" time of 1 second (the logger must apply the power 1 second   before taking its reading).   • The output voltage will be stable 120 ms after applying external power, and is   updated every 60 ms while external power remains connected.   74 • Appendices   Document code: SS1-UM-1.05   B. Logging the Beam Fraction sensor   You can log the Beam Fraction sensor in a similar manner, using the (optional)   special logging cable for it. Two outputs are available, corresponding to the Total   incident PAR and Diffuse PAR photodiode readings.   Be aware that the shade ring elevation may need readjustment after an hour or two.   Also, that separately logged incident PAR readings cannot at present be merged   with probe readings of transmitted PAR to give LAI estimates using the SunScan   mathematical model.   Wiring connections   The Beam Fraction sensor logging cable plugs into the BFS cable connector, giving   up to 12 metres distance from the logger. If you need more length, simply join on   extra screened multicore cable of a similar type. Make sure the joint is weatherproof.   The cores of the BFS logging cable have the following functionality:   Core   Function   Logger Connection   orange   green   brown   V+ Power supply positive   0V Power supply negative   HI Total PAR signal output   positive   Sensor power positive (switched for warm-up)   Sensor power negative (0V)   Input channel +, for Total PAR   grey   blue   braid   LO Common signal output   negative   HI Diffuse PAR signal output   positive   Input channels - common negative   Input channel +, for Diffuse PAR   Frame earth, or 0V   Screen   Note: the grey and green are connected internally in the BFS case. The braid is not   connected to any other core.   Output   • The output signals are the Total and the Diffuse PAR irradiance.   • The millivolt outputs are linear, with a sensitivity of 1 mV = 1 µmol.m-2.s-1.   Maximum output is dependent on the supply voltage, and can exceed 2500 mV.   Logger requirements   • The BFS requires a voltage supply of 5-15 V dc (unregulated), at about 1 mA   current.   Warning! Pre-Release Beam Fraction sensors require a regulated voltage supply of   5 V dc (±0.25 V). Refer to Delta-T if you are uncertain about this.   • Configure two logger channels for voltage input, with the above sensitivity.   • Use a "warm-up" time of 1 second (the logger must apply the power 1 second   before taking its reading). Outputs will be stable after 10 ms.   SunScan User Manual v 1.05   Appendices • 75   C. Upgrading the SunScan system   From time to time, new issues of the software programs in the SunScan system may   be released and offered to existing customers. Brief notes follow for what is   involved in installing them.   The SunData PC s/w   New versions of the PC program file SunData.exe will be provided on a floppy   disk. Rename the existing file on your PC's hard disk, then copy the new file across   to the same directory as was previously used.   The Workabout SunData s/w   New versions of the SunData.app file (and any other files needed in the Psion),   must be copied across to the Workabout and the application installed. To do this,   you will need to use the SLINK or RCOM file transfer utilities, or the PsiWin   program if you have it.   Once you have copied across the new program file, you will need to install the   SunData application as described in the section More Psion and file handling notes.   Revision History   Full release versions of hardware, software and documentation are v1.05 or later   (December 1996).   Pre-Release units were issued before this time. A free of charge upgrade has been   offered to all pre-release customers. If you are unsure about the status of your   equipment, please refer to the earlier Technical Support section of this manual for   how to locate version and serial numbers, then contact your agent or Delta-T.   76 • Appendices   Document code: SS1-UM-1.05   D. File transfer between Workabout and PC   Choice of different programs   For the transfer of data files from the Workabout to a PC, the SunData software that   resides in the Workabout and on your PC provides all you need, but it is specific for   this purpose. There are other occasions however when you may want to transfer   other files between the PC and the Workabout, for example to send an upgraded   version of the SunData.app file to the Workabout.   To do this, there are three routes. We provide two DOS utility programs from Psion   plc on the SunData diskette called SLINK and RCOM. The main difference   between these programs is that RCOM is operated from your PC keyboard with   DOS-like commands, whereas SLINK lets you use the Workabout's own file and   directory screens, and no input is required from the PC. Documentation text files are   included on the SunData diskette.   If you are familiar with the Workabout's screens then you will probably find SLINK   is the easiest route to master quickly.   In addition, we offer as an option the Psion PsiWin program for Windows, which is   an excellent application program for handling communications between PCs and   various computers in the Psion range. Contact your agent or Delta-T if you wish to   purchase a copy.   The Workabout Remote Link   We give you below some notes on using each of these programs. In every case you   must set the Workabout's Remote Link on. Access this from the Psion System screen   with ∪+L, or press Menu, Spec, Remote Link, Enter.   Warning! Don't forget to turn the Remote Link off when you have finished. If you   neglect this, you will get a "Failed to open Serial Port In use" message when you   next try to run SunData in the Workabout.   PsiWin   PsiWin is a well documented program with a full User Manual and on-screen Help.   It uses a screen layout very similar to Windows File Manager. When communication   is established between your PC and the Workabout, you can drag and drop files   between different drives and directories, and of course do very much more   ♦ Install and run PsiWin on your PC.   ♦ Connect the Workabout to your PC COM port with the SunScan RS232 comms   cable.   ♦ On your Workabout, exit from the SunData program if necessary (∪+X). Access   the Remote Link dialog (∪+L) and set the link on, port A and with 19200 Baud.   In PsiWin:   The Setup, Communications... menu deals with COM ports and serial data   parameters. Check that they correspond exactly with those of the Workabout remote   link.   The Setup, Conversions... menu deals with file conversions. This is not needed for   any file transfer. Make sure Conversion is Off.   Window, Refresh is worth doing when verifying that a file has been transferred to a   new drive or directory.   SunScan User Manual v 1.05   Appendices • 77   If PsiWin has difficulty establishing the link to the Workabout at any stage,   powering down PsiWin and the Workabout and physically remaking the RS232   connections before running them again may clear the problem.   Don't forget to turn off the remote link in the Workabout when you have finished.   SLINK and RCOM   The procedure   For maximum safety, to start with, close down all other applications on the PC, and   run everything from the DOS prompt whilst you do this.   Both programs follow a similar procedure in general.   ♦ On your PC, copy the RCOM and SLINK files on to your hard disk if you have   not already done so by following the Getting Started section in the User Manual.   ♦ On the Workabout, exit the SunData s/w, and set up the Remote Link parameters   in the Psion's system.   ♦ Connect the Workabout comms cable between the RS232 port on the Workabout   and the COM1 serial port on your PC. (If you can't use COM1 you must refer to   the program documentation to enable it to use COM2).   ♦ Run whichever program you have chosen, and copy the appropriate files across.   Verify that the file names now appear in the new directories.   ♦ Exit from the transfer program on your PC.   ♦ Close down the Remote Link on the Workabout.   Example using SLINK   SLINK lets you initiate all the file transfer commands from the Workabout's screens   and menus. Consult the earlier section More Psion and file handling notes first if   you are not adequately familiar with the Psion's routines.   On the Workabout:   ♦ Exit from the SunData application (if necessary) by pressing ∪+X.   ♦ In the System Screen, press Menu, Spec, Remote Link, and press Enter. Set the   Remote link to On, Baud rate to 9600, and the Port to A. Press Enter to accept.   ♦ Connect the RS232 port at the top right of the Workabout to the PC’s COM1   serial port with the SunScan comms cable.   On your PC:   ♦ Exit Windows. From the DOS prompt, in the directory holding SLINK.EXE,   type: SLINK ↵   You will get an SLINK acknowledgement like this (or similar):   Psion MC/HC/Series3 File Server Version 1.2 - Copyright (C) Psion Plc 1991   Press Q to Quit   As an example, let us consider how to transfer a new version of the SunData   program to the Workabout from your PC. We will assume you have already copied   the program file SunData.app into a directory called C:\SUNSCAN\PSION on your   Hard Disk.   The same process can be used if you need to re-load the SunData program for any   reason.   SunData.app needs to run from a subdirectory \SUN\ on the Internal drive. You   must create this, if it is not already present.   On the Workabout:   78 • Appendices   Document code: SS1-UM-1.05   ♦ From the Psion System Screen, press Menu, Disk, Directory, Enter.   ♦ Press ← → to select the Disk Internal, (or any other Disks or drives).   Note: the Workabout refers to its own drives as Internal and Disk A, B, C etc . The   drives on the PC are referred to as REM::A:, REM::C: (REM = remote).   If no subdirectory \SUN\ exists, then create one as follows:   ♦ Select \, the root directory of the Disk Internal   ♦ Press Menu, Directory, Make directory, Enter.   ♦ For Dir. Name type \SUN and press Enter.   ♦ Access the directories again with Menu, Disk, Directory, Enter.   The new subdirectory \SUN\ will now be listed under the root directory of the   Internal Disk.   ♦ Now press ← → to move to the REM::C: drive (your PC's hard disk) and enter the   \SUNSCAN\PSION directory.   ♦ Press ↑ or ↓ to highlight the file Sundata.app. Don't press Enter!   ♦ Press Menu, File, Copy file, Enter.   ♦ Complete the dialog box as shown below, noting the general advice.   You must specify the full   subdirectory path of the Disk. Start   and finish with backslashes(\).   If you leave the filename blank after   the backslash, the original filename   will be used. If you want to change   the filename, type in the new   filename, with its extension, after the   directory path.   ♦ Press Enter to accept, when you are happy with all the details.   The Workabout will warn you if you have chosen a filename that already exists, and   offer you various options. Otherwise it will proceed, and briefly advise you of the   copying process.   A copy of the file is now in the new location you have specified.   You must also copy across the file Sys$8087.ldd to the same directory on the   Workabout, for the SunData program to run properly. You can do this by a similar   procedure. Finally:   ♦ On your PC, quit the SLINK program by typing Q.   ♦ On the Workabout, close down the Remote Link: From the System Screen, press   Menu, Spec, Remote Link, and set it to Off, then press Enter.   If the SunData icon does not automatically appear in the Psion System screen, see   More Psion and file handling notes about re-installing SunData as an application.   SunScan User Manual v 1.05   Appendices • 79   Example using RCOM   On the Workabout:   ♦ Exit from the SunData application on the Workabout by pressing ∪+X.   ♦ In the System Screen, press Menu, Spec, Remote Link, and press Enter. Set the   Remote Link to On, Baud rate to 19200, and the Port to A.   ♦ Connect the RS232 port at the top right of the Workabout to the PC’s COM1   serial port using the SunScan comms cable.   From the PC   ♦ At the DOS prompt, in the directory holding RCOM.EXE, type: RCOM↵   (Let's assume this is in your C:\SUNSCAN\COMMS directory)   The RCOM prompt "»" followed by the current subdirectory name will appear, in a   DOS-like screen.   You should now be able to get a directory listing of the Workabout Internal Disk on   your PC by typing DIR I: ↵ at the prompt.   Note: in RCOM, the Workabout drives A, B and Internal are mapped onto drives L,   R and I.   ♦ If the subdirectory \SUN\ does   not exist you must create it as   follows:   >>C:\SUNSCAN\COMMS>I:↵   >> I:\>md\sun↵   ♦ Check the new subdirectory   now exists:   >> I:\>dir↵   ♦ Then type   >> I:\>copy   c:\sunscan\psion\*.* I:\sun\↵   This copies both the SunData program sundata.app and sys$8087.ldd, which is   also required, to the Workabout Internal drive subdirectory \SUN\ and confirms the   process. When you have finished:   ♦ On your PC, type EXIT↵ to exit from RCOM   ♦ On the Workabout, close down the Remote Link: From the System Screen, press   Menu, Spec, Remote Link, and set it to Off, then press Enter.   If the SunData icon does not automatically appear in the Psion System screen, see   More Psion and file handling notes about re-installing SunData as an application.   Documentation of RCOM and SLINK   If you have been successful with the above transfer instructions, you can skip this,   but if you need to know more about either RCOM or SLINK, the SunData s/w   diskette contains text files in the \COMMS directory which explain the operation of   the transfer programs.   • COMMS.TXT gives brief details of the operation of both SLINK and RCOM.   • RCOM.TXT is a text file containing the full RCOM manual.   80 • Appendices   Document code: SS1-UM-1.05   E. Alternative file transfer mechanisms   Sending a file to a Communication program   You can send your files to a communications program such as Windows Terminal or   ProComm. However, if you do this there will be no error checking during the file   transfer.   Connect the Workabout to an appropriate serial port on the PC using the SunScan   RS232 cable or a null modem serial cable.   In the communications program   Set the COM port you are using to 9600 baud, No parity, 8 data bits, 1 stop bit.   Select either hardware (RTS/CTS) or software (XON/XOFF) handshaking.   Select “capture to file” or “receive text file” and the filename you want to store the   data in.   In SunData on the Workabout   Select Menu, File, File Transfer, Enter, and select the file you want to send.   The Workabout will send “start of header” (SOH ASCII 01) followed by the   filename.   After a few seconds, the message “no response from receive program” will appear.   Select continue and the Workabout will send “start of text” (STX ASCII 02) then   continue transmitting the file. You should see this appear on the communications   program screen.   You can stop the transfer by pressing On/Esc on the Workabout, or Ctrl+X in the   communications program.   After the file has been sent, the Workabout will finally send “end of text” (ETX   ASCII 03) and a file checksum value. A few seconds later the message “no   acknowledgement from receive program” will appear. Select Quit.   Now close your file in the communications program.   Sending a file to a serial printer   You can print files out directly to a printer with a serial port. You must set the   printer serial port to 9600 baud, No parity, 8 data bits, 1 stop bit, with either   hardware (RTS/CTS) or software (XON/XOFF) handshaking. This is usually done   by setting switches or jumpers inside the printer, and will be explained in the printer   manual. Connect the printer to the Workabout using the SunScan RS232 cable or a   null modem cable.   Proceed on the Workabout as described in the paragraph above.   Using the Workabout COMMS application   There is a built in communications program accessible from the Workabout system   screen. This supports various protocols including XMODEM and YMODEM, and   will support file transfer via a modem. The use of this is described in the Workabout   manual on pages 52-58.   SunScan User Manual v 1.05   Appendices • 81   F. Glossary   Beam fraction - the fraction of the Total incident PAR in the Direct beam.   Beam Fraction Sensor (BFS) - consists of two PAR sensors and a shade ring, used   for measuring Direct and Diffuse light above the canopy.   Beer’s law - a general law describing transmission through an absorbing medium.   The intensity falls off exponentially with distance through the medium.   Cosine response - the response of a sensor to a ray of light is proportional to the   cosine of the angle of incidence of the ray (measured from the perpendicular to the   sensor surface).   CSV (Comma Separated Variable) a file format intended for importing into   spreadsheet or database programs. Fields are separated by commas, text is enclosed   in quotes.   Data Collection Terminal - the Psion Workabout handheld computer, used for   driving the SunScan probe, and presenting and storing the results.   Diffuse light - light scattered in the atmosphere. It is treated as coming from all parts   of the sky with equal intensity i.e. a Uniform Overcast Sky.   Direct beam - light coming directly from the sun, with no scattering. Usually treated   as if it comes from a point source.   ELADP - see Leaf Angle Distribution   Emulator - a setting in the SunData software that generates random results,   regardless of whether a SunScan probe is connected. Useful for learning to use the   software.   GMT - Greenwich Mean Time, also called Universal Time (UT). The standard time   used for astronomical measurements and calculations.   Hemispherical response - the response of the sensor is equal for all light rays   coming from above the plane of the sensor surface, independent of angle.   LAD - see Leaf Angle Distribution.   LAI - see Leaf Area Index.   Leaf absorption - the fraction of intercepted PAR that is actually absorbed by the   leaf. The remainder is reflected or scattered.   Leaf Angle Distribution - a way of describing the distribution of orientations in   space of the canopy elements. We model this using the Ellipsoidal Leaf Angle   Distribution, which describes the distribution of canopy elements as in the same   proportions as the surface of an ellipsoid. Using this model, a wide range of different   canopy types can be described by a single parameter, the Ellipsoidal Leaf Angle   Distribution Parameter (ELADP), which is the ratio of the horizontal to vertical axes   of the ellipsoid. An ELADP much greater than 1 describes a canopy of mostly   horizontal leaves, an ELADP near 0 describes a canopy of mainly vertical leaves.   Leaf Area Index (LAI) - the surface area of leaf per unit of ground area (assuming   leaves are flat, and including only one side of each leaf). Instruments like the   SunScan cannot differentiate between leaf and stem, so could more correctly be said   to estimate Plant Area Index.   82 • Appendices   Document code: SS1-UM-1.05   Local time - the time used in your particular time zone. It varies from GMT by an   amount depending on longitude, political boundaries, and any daylight saving time.   Mean Leaf Angle (also Mean Tip Angle, Mean Inclination Angle) is the average   angle of all the leaf elements relative to the horizontal, weighted according to area.   This can be directly related to ELADP.   PAR - Photosynthetically Active Radiation is visible light of wavelength 400 nm -   700 nm. It is measured in units of µmol.m-2.s-1 (micromoles per square metre per   second) or formerly µE (micro-Einstein). The normal daylight maximum is a little   over 2000 µmol.m-2.s-1 .   PAR mapping - the study of distribution and variation of PAR within and below a   canopy.   PRN a text file format intended for directly printable output.   Spread - a measure of the relative variation in light intensity along the SunScan   probe. It is calculated as the Standard Deviation divided by the Mean (sometimes   called coefficient of variation).   SunData software- the software used to drive the SunScan probe and calculate and   store the results. There are two versions, one which runs in the Psion Workabout, the   other in an IBM compatible PC. They are functionally very similar.   SunScan probe - the long light sensitive wand and handle used for light readings   within the canopy.   Total PAR - the sum of Direct beam PAR and the Diffuse light PAR.   Transmission fraction - the fraction of incident light that passes through a given   canopy. It can refer to Direct, Diffuse, or Total incident light.   Zenith angle - the angle between the centre of the sun and the point directly   overhead.   SunScan User Manual v 1.05   • 83   Index   Constants.............................................................18, 30   Continue....................................................................16   Copyright ..............................................................2, 53   Cosine response...................................................71, 80   CSV files.......................................................19, 37, 80   A About ........................................................................ 31   Absorption   incomplete................................................. 52, 56, 59   values .................................................................... 42   Accuracy   D LAI........................................................................ 58   PAR................................................................. 48, 49   All, display................................................................ 44   Appending data......................................................... 19   ASCII text................................................................... 7   Assumptions, theory ........................................... 53, 56   Autolog........................................................... 6, 31, 45   Average interval........................................................ 31   Averages ................................................................... 24   Data   groups....................................................................38   memory..................................................................35   Data Collection Terminal................................7, 68, 80   Data file.....................................................................36   display ...................................................................37   layout.....................................................................38   Data Storage........................................................19, 30   Data.prn...............................................................19, 36   Default.cfg...........................................................36, 65   Desiccant...................................................................63   Diffuse light ..................................................39, 54, 80   Diffusers....................................................................50   Direct beam.........................................................39, 80   Discard......................................................................21   Display................................................................18, 31   B B FRAC.................................................................... 23   Batteries.............................................................. 46, 62   checking .......................................... 9, 12, 14, 65, 66   Beam fraction............................................................ 80   Beam Fraction Sensor..................................... 7, 21, 80   Beeps .................................................................. 22, 46   Beer's Law .......................................................... 43, 80   BFS   extension cables .................................................... 48   field use................................................................. 47   levelling................................................................. 48   specs...................................................................... 68   E ELADP......................................................................80   estimating ..............................................................43   setting ....................................................................42   Emulator..................................................16, 20, 30, 80   Exit............................................................................30   Experiment design.....................................................39   Ext sensor............................................................16, 21   Extension cables....................................................7, 48   Extinction coefficient................................................54   C Calibrate ................................................................... 31   Calibration   factory ............................................................. 49, 64   restore................................................................ 31   Campbell's equations ................................................ 52   Canopy   model..................................................................... 57   sampling volume ................................................... 40   Canopy types   clumped................................................................. 40   real ........................................................................ 40   Carrying Case ........................................................... 69   CE marks .................................................................... 2   Circuit schematics..................................................... 67   COM ports, PC ......................................................... 11   Comms Test.............................................................. 31   Communication program .......................................... 79   Communications   checks.................................................................... 12   Communications failed ....................................... 15, 21   Compass.................................................................... 47   Configuration files .................................................... 35   Connect..................................................................... 12   F File ............................................................................19   Review...................................................................24   Saving....................................................................19   Transfer ...........................................................25, 75   alternatives.........................................................79   dialog .................................................................26   Files, Psion   deleting..................................................................34   Flashcard.........................................................7, 34, 65   Format CSV ........................................................25, 30   Fractional interception ................................................6   G GMT....................................................................18, 80   GO button............................................................12, 46   Group   number...................................................................38   title.........................................................................38   Guarantee ..................................................................67   84 • Index   Document code: SS1-UM-1.05   H Problem reports ........................................................ 67   Protection, moisture.................................................. 51   Psion   Logo screen........................................................... 33   subdirectories........................................................ 33   System screen.............................................. 8, 14, 33   PsiWin ...................................................................... 75   Hemispherical response.......................................58, 80   Hot keys ..............................................................19, 32   I Inversion....................................................................53   L Q LAI, display...............................................................44   LAI, theory................................................................52   Latitude .....................................................................18   Leaf absorption..........................................................80   Leaf Angle Distribution.............................................80   Leaf Area Index.....................................................6, 80   Levelling .............................................................22, 46   Light conditions   preferred ................................................................41   sun position............................................................41   Linear Quantum sensor..........................................6, 72   Local time..................................................................81   Logging   Quit........................................................................... 31   R RCOM ...................................................................... 76   Read interval............................................................. 31   Readings ................................................................... 20   Recalibrate.......................................................... 31, 49   References ................................................................ 61   Remote Link ....................................................... 21, 65   Reset ......................................................................... 15   Restore   calibration ............................................................. 50   Config'n................................................................. 30   Review...................................................................... 30   Revision history........................................................ 74   RS232   BFS........................................................................73   cables.....................................................................69   Probe......................................................................72   Longitude ..................................................................18   communications .............................................. 28, 66   M S Manuals.......................................................................6   Mean Leaf Angle.................................................43, 81   Measurement procedures   field........................................................................46   Memory...............................................................46, 65   Menus..................................................................18, 30   Sample name............................................................. 31   Save Config'n...................................................... 19, 30   Serial numbers .......................................................... 67   Serial printer............................................................. 79   Settings ............................................................... 16, 18   Shade ring........................................................... 22, 50   Site...................................................................... 18, 31   Sleep..................................................................... 9, 31   SLINK ...................................................................... 76   Spares kit .................................................................. 69   Specifications............................................................ 68   Spectral response...................................................... 70   Spread................................................................. 50, 81   Store.......................................................................... 21   SunData s/w........................................................ 74, 81   diskette.................................................................. 10   Icon ................................................................. 34, 65   installation............................................................. 10   SunData.app.............................................................. 65   SunData.exe.............................................................. 11   SunScan probe................................ 7, 8, 16, 21, 30, 65   specs...................................................................... 68   Sys$8087.ldd ............................................................ 65   N Navigating   Psion ................................................................14, 32   Night time..................................................................31   North, setting.......................................................22, 48   Notes .........................................................................20   P PAR.......................................................................6, 81   calibration..................................................49, 50, 64   mapping .......................................................6, 44, 81   profiling.................................................................44   sensor, independent................................................39   Total.......................................................................81   PAR, display .............................................................44   PC   Data Collection......................................................68   instead of Workabout.................................14, 16, 25   portable..............................................................7, 37   PC software ...............................................................16   Photodiodes.........................................................21, 44   Plot name...................................................................31   PRN files.............................................................37, 81   T Tab key..................................................................... 19   Technical Reference section..................................... 62   Technical Support..................................................... 67   Time & Date....................................................... 18, 31   Titles......................................................................... 31   SunScan User Manual v 1.05   Index • 85   Transfer, file ............................................................. 30   Transmitted fraction.................................................. 81   Tripod Mount...................................................... 47, 69   Troubleshooting.............................................. 8, 27, 65   Tutorial ..................................................................... 14   software .........................8, 10, 15, 32, 34, 35, 45, 75   Weather   preferred ................................................................41   Windows, running SunData.......................................13   Wood's SunScan equations........................................53   Workabout.......................................................8, 47, 65   charger.....................................................................9   COMMS................................................................79   hardware ..................................................................9   keys........................................................................15   screens ...................................................................29   setup ......................................................................44   U Upgrades................................................................... 74   Utilities ..................................................................... 41   Utils .......................................................................... 31   V Version numbers....................................................... 67   Z W Zenith angle.........................................................60, 81   Solar Predictor.................................................41, 60   Zoom.........................................................................30   Warnings   field use............................. 39, 46, 48, 50, 51, 58, 64   general......................................................... 2, 54, 73   hardware.................................................... 50, 62, 63   86 • Index   Document code: SS1-UM-1.05   |