Dell POWEREDGE R710 User Manual

Dell™  
POWeReDGe™  
R710  
technical GuiDebOOk  
insiDe the POWeReDGe R710  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 5. blOck DiaGRam  
19  
sectiOn 6. PROcessORs  
A. Overview / Description  
B. Features  
21  
21  
21  
C. Supported Processors  
D. Processor Configurations  
21  
22  
sectiOn 7. memORy  
A. Overview / Description  
23  
23  
23  
24  
27  
27  
28  
28  
28  
B. DIMMs Supported  
C. Speed  
D. Slots / Risers  
E. Supported Configurations  
F. Mirroring  
G. Advanced ECC (Lockstep) Modes  
H. Optimizer (Independent Channel) Mode  
sectiOn 8. chiPset  
A. Overview / Description  
29  
29  
sectiOn 9. biOs  
31  
31  
A. Overview / Description  
B. Supported ACPI States  
C. I2C (Inter-Integrated Circuit)  
31  
32  
sectiOn 10. embeDDeD nics / lan On mOtheRbOaRD (lOm)  
A. Overview / Description  
32  
32  
sectiOn 11. i/O slOts  
A. Overview / Description  
B. PCI Express Risers  
33  
33  
35  
35  
35  
35  
C. Additional Riser Restrictions  
D. X16 Express Card Specifications  
E. Boot Order  
sectiOn 12. stORaGe  
A. Overview / Description  
B. Drives  
36  
36  
36  
36  
37  
37  
38  
38  
38  
I. Internal Hard Disk drives  
II. Hard Disk Drive Carriers  
III. Empty Drive Bays  
IV. Diskless Configuration Support  
V. Hard Drive LED Indicators  
C. RAID Configurations  
Dell™ PowerEdge™ R710 Technical Guidebook  
D. Storage Controllers  
I. SAS 6/iR  
39  
39  
40  
41  
II. PERC 6i  
E. LED Indicators  
F. Optical Drives  
G. Tape Drives  
41  
41  
sectiOn 13. viDeO  
A. Overview / Description  
42  
42  
sectiOn 14. auDiO  
A. Overview / Description  
43  
43  
sectiOn 15. Rack infORmatiOn  
A. Overview / Description  
B. Cable Management Arm (CMA)  
C. Rails  
43  
43  
43  
44  
sectiOn 16. OPeRatinG systems  
A. Overview / Description  
45  
45  
sectiOn 17. viRtualizatiOn  
A. Overview / Description  
47  
47  
sectiOn 18. systems manaGement  
A. Overview / Description  
47  
47  
47  
48  
48  
48  
49  
49  
B. Server Management  
C. Embedded Server Management  
I. Unmanaged Persistent Storage  
II. Lifecycle Controller/Unified Server Configurator  
III. iDRAC6 Express  
IV. iDRAC6 Enterprise  
sectiOn 19. PeRiPheRals  
A. USB peripherals  
52  
52  
52  
B. External Storage  
sectiOn 20. DOcumentatiOn  
A. Overview, Description, and List  
53  
53  
sectiOn 21. PackaGinG OPtiOns  
aPPenDix  
53  
54  
Dell™ PowerEdge™ R710 Technical Guidebook  
the Dell™ POWeReDGe™ R710  
The Dell PowerEdge R710 is designed to be the cornerstone of today’s competitive enterprise.  
Engineered in response to input from IT professionals, it is the next-generation 2U rack server  
created to efficiently address a wide range of key business applications. The successor to the  
PowerEdge 2950 III, the R710 runs the Intel® Xeon® 5500 Series Processors and helps you lower  
the total cost of ownership with enhanced virtualization capabilities, improved energy efficiency,  
and innovative system management tools.  
strong it foundation  
As an IT professional, you want a data center built to allow for organic growth and the ability to scale  
based on your company’s changing requirements. You need complete solutions that allow you to  
focus your time and money on managing and growing your business. Dell understands your needs and  
responds with an expanding portfolio of enterprise servers, storage technologies, and services with a  
single goal: to help you simplify IT.  
Purposeful Design  
The R710 takes advantage of Dell’s system commonality. Once your IT managers learn one system, they  
understand how to manage next-generation Dell servers. Logical component layout and power supply  
placement also provide a straightforward installation and redeployment experience. Featuring 18 DIMM  
slots and 4 integrated network connections, the R710 delivers the critical components to virtualization  
and database performance. The Intel Xeon Processor 5500 Series adapts to your software in real time,  
processing more tasks simultaneously. Using Intel® Turbo Boost Technology, the R710 can increase  
performance during peak usage periods. You can then help reduce operating costs and energy usage  
with Intel® Intelligent Power Technology, which proactively puts your server into lower power states when  
demand decreases. Increased memory slots also save money by enabling you to use smaller,  
less-expensive DIMMs to meet your computing needs.  
enhanced virtualization  
Featuring Intel Xeon-based architecture, embedded hypervisors, large memory capacity, and integrated  
I/O, the next-generation Dell PowerEdge R710 delivers better overall system performance and greater  
virtual machine-per-server capacity. With optional factory-integrated virtualization capabilities, you get  
tailored solutions – built with the latest technologies from Dell and our trusted partners – which allow  
you to streamline deployment and simplify virtual infrastructures. Choose your hypervisor from market  
leaders such as VMware®, Citrix®, and Microsoft®, and enable virtualization with a few mouse clicks.  
energy-Optimized technologies  
Using the latest Energy Smart technologies, the R710 reduces power consumption while increasing  
performance capacity versus the previous generation servers. Enhancements include efficient power  
supply units right-sized for system requirements, improved system-level design efficiency, policy-driven  
power and thermal management, and highly efficient standards-based Energy Smart components. Dell's  
advanced thermal control delivers optimal performance at minimal system and fan power consumption  
resulting in our quietest 2U servers to date. These enhancements maximize energy efficiency across our  
latest core data center servers without compromising enterprise performance.  
simplied systems management  
Gain more control with the next-generation Dell OpenManage™ suite of management tools. These tools  
provide enhanced operations and standards-based commands designed to integrate with existing  
systems for effective control. Dell Management Console (DMC) helps simplify operations and creates  
stability by shrinking infrastructure management to one console. This console delivers a single view and  
a common data source into the entire infrastructure management. Built on Symantec® Management  
Platform, it has an easily extensible, modular foundation that can provide basic hardware management  
all the way up to more advanced functions, such as asset and security management. Dell Management  
Console reduces or eliminates manual processes, enabling you to save time and money for more  
5
Dell™ PowerEdge™ R710 Technical Guidebook  
strategic technology usage. Secure, efficient, and more user friendly than its predecessors, the Dell  
Unified Server Configurator (USC) delivers “Instant On” integrated manageability through a single  
access point. You get quick, persistent access to the tool because it is embedded and integrated into  
the system for increased flexibility and capabilities. The USC is a one-stop shop for deploying operating  
systems with built-in driver installations, firmware updates, hardware configuration, and issue diagnoses.  
sectiOn 1. system OveRvieW  
a. Overview / Description  
The PowerEdge R710 will lead Dell's 11th Generation PowerEdge portfolio in key areas of differentiation,  
primarily:  
• Virtualization  
• Power, thermal, efficiency  
• Systems management, and usability  
b. Product features summary  
featuRe  
Details  
Processor  
Nehalem EP  
Front Side Bus  
# Procs  
Intel® QuickPath Interconnect (QPI) @ maximum 6.GT/s  
2S  
# Cores  
4 cores  
L2/L3 Cache  
Chipset  
4MB and 8MB  
Tylersberg  
DIMMs/Speed  
Min/Max RAM  
18 RDIMM or UDIMM DDR3 (9 per processor)  
1GB – 144GB  
Internal hard drive bay and hot-plug backplane  
HD Bays  
Up to six 3.5" SAS or SATA drives without optional flex bay OR  
Up to eight 2.5" SAS or SATA drives with optional flex bay  
HD Types  
SAS, SATA, Near-line SAS, and SSD  
Ext Drive Bay(s)  
Optional flex-bay expansion to support a half-height TBU  
Int. HD Controller PERC 6i and SAS 6/iR  
Opt. HD Controller  
BIOS  
Video  
Based on the Matrox G200 w/iDRAC  
Availability  
Server  
Management  
I/O Slots  
Two x8 and two x4 PCIe Gen2 slots or One x16 PCIe slot and two x4 PCIe Gen2  
6
Dell™ PowerEdge™ R710 Technical Guidebook  
featuRe  
Details  
RAID  
PERC 6i utilizing battery backed 256MB DDRII 667  
Broadcom 5809C (2 cards/4ports)  
NIC/LOM  
USB  
Five (two front, two rear, one internal)  
Two hot-plug high-efficient 570W PSU OR  
Two hot-plug 870W PSUs (1+1)  
Power Supplies  
The system control panel is located on the front of the system chassis to provide  
user access to buttons, display, and I/O interfaces  
Front Control  
Panel  
System ID  
Front and rear (0x0235)  
Five hot-swappable  
Fans  
Additional fan integrated into each power supply  
Single processor configurations will only have four fans  
Chassis  
2u Rackmount  
sectiOn 2. mechanical  
a. chassis Description  
PowerEdge R710 is a 2U rackmount chassis. The updated design includes a new LCD, bezel and  
hard-drive carriers. Additional changes include tool-less rack latches, a pull out tray for customer labels,  
and LOM0/iDRAC MAC address; labels; support persistent storage (internal USB and SD card slots and  
external SD card slots); updated power supplies and removal process.  
From view 3.5" HDD Chassis (without bezel)  
From view 2.5" HDD Chassis (without bezel)  
7
Dell™ PowerEdge™ R710 Technical Guidebook  
b. Dimensions and Weight  
Height  
8.64cm (3.40")  
44.31cm (17.44")  
68.07cm (26.80")  
26.1kg (57.54lbs)  
Width  
Depth  
Weight (maximum config)  
.
c. front Panel view and features  
Front I/O panel access including USB and VGA interfaces. The following components are located on  
the front:  
• Express service tag (Information tag). A slide-out panel for system identification labels  
• Power on indicator, power button  
• NMI indicator (Nonmaskable interrupt). A device sends an NMI to signal the processor about  
hardware errors. It is used to troubleshoot software and device driver errors when using certain  
operating systems  
• (2) USB connectors. Connects USB devices to the system. The ports are USB 2.0 compliant  
• Video connector  
• LCD menu buttons. Allows you to navigate the control panel LCD menu  
• LCD panel. Provides system ID, status information, and system error messages  
• System identification button  
• Optical drive (optional)  
• Hard drives  
• Flex bay  
D. back Panel view and features  
The following components are located on the rear panel of the R710 enclosure:  
• (1) 15-pin VGA connector  
• (1) 9-pin serial port connector  
• (4) 10/100/1000 Ethernet RJ-45 connectors  
• (1) Rear system ID button  
• (1) Active ID Cable Management Arm external LED jack  
• (2) USB ports  
• (1) (Optional) iDRAC6 Enterprise RJ-45 connector  
• (1) Optional) iDRAC6 Express SD module  
8
Dell™ PowerEdge™ R710 Technical Guidebook  
e. Power supply indicators  
The PSUs on the PE R710 have one status bi-color LED: green for AC power present and amber for  
a fault.  
leD  
POWeR suPPly status  
AC power is not present  
AC power is present  
Fault of any kind is detected  
DC power is applied to the system  
PSU mismatch (when hot-added/swapped)  
Table: Power Supply Indicator  
f. nic indicators  
inDicatOR  
inDicatOR cODe  
Link and activity indicators are off  
Link indicator is green  
The NIC is not connected to the network  
The NIC is connected to a valid network link at 1000 Mbps  
The NIC is connected to a valid network link at 1000 Mbps  
Network data is being sent or received  
Link indicator is amber  
Activity indicator is green blinking  
G. side views and features  
9
Dell™ PowerEdge™ R710 Technical Guidebook  
h. Rails and cable management  
Rack installation components such as rails are provided with the PowerEdge R710 Rack Kit. The rack  
installation components are as follows: Sliding rack mount with latest generation Cable Management  
Arm (CMA). When the system is installed in a rack, please observe the following guideline:  
When the system is installed in a rack, only Dell-approved CMAs should be installed behind  
the chassis.  
Rails  
• Enable the replacement of thumbscrews with slam latches on the chassis for easier stowing in  
the rack.  
• Include the new simple and intuitive ReadyRail™ tool-less rack interface for square-hole and  
round-hole racks.  
• Provide significantly improved compatibility with non-Dell racks.  
• Static rails for the R610 & R710 fit in all types of four-post and two-post racks available in the  
industry including four-post threaded hole racks.  
CMAs  
• Provide much larger vent pattern for improved airflow through the CMA.  
• Include a common support tray for eliminating CMA sag.  
• Replaced tie wraps with hook and loop straps to eliminate risk of cable damage during cycling.  
• Maintain key feature of being fully reversible with no conversion required.  
i. fans  
Fans  
Five hot-swappable fans are mounted in a fan gantry that is located in the chassis between the hard  
drive bay and the processors. Each fan has a blind mate 2x2 connector that plugs directly into the  
planar. There is an additional fan integrated in each power supply to cool the power supply subsystem  
and also provide additional cooling for the whole system. Single processor configurations will have four  
fans populated.  
The Embedded Server Management logic in the system monitors the speed of the fans. A fan failure  
or over-temperature in the system results in a notification by iDRAC6. All system fans are pulse-width  
modulated fans. Redundant cooling is supported with one fan failing at a time.  
10  
Dell™ PowerEdge™ R710 Technical Guidebook  
J. control Panel / lcD  
The control panel board is connected to the planar via a 60-wire ribbon cable and a separate 5-wire  
cable for USB signals only. The LCD plugs into the control panel through a 20-pin ZIF connector and  
flex cable.  
The system control panel is located on the front of the system chassis to provide user access to  
switches, display, and I/O interfaces. Features of the system control panel are:  
• ACPI-compliant power button with an integrated green power LED (controlled by ESM)  
• 128x20 pixel LCD with controls  
Two navigation buttons  
• One-select button  
• One system ID button  
• Non-Maskable-Interrupt (NMI) button (recessed)  
• Ambient temperature sensor  
Two external USB 2.0 connectors (with two internal connectors dedicated for UIPS)  
• 15-pin VGA connector  
The LCD panel is a graphics display controlled by the BMC/ESM. Both ESM and BIOS can send error  
codes and messages to the display.  
The system’s LCD panel provides system information and status messages to signify when the system is  
operating correctly or when the system needs attention.  
The LCD backlight lights blue during normal operating conditions and lights amber to indicate an error  
condition. When the system is in standby mode, the LCD backlight is off and can be turned on by  
pressing the Select button on the LCD panel. The LCD backlight will remain off if the “No Message"  
option is selected through the iDRAC6, the LCD panel, or other tools.  
BIOS has the ability to enter a “Secure Mode" through Setup, which locks the power and NMI buttons.  
When in this mode, pressing either button has no effect but does not mask other sources of NMI and  
power control.  
k. security  
I. Cover Latch  
A tooled entry latch is provided on the top of the unit to secure the top cover to the chassis  
11  
Dell™ PowerEdge™ R710 Technical Guidebook  
II. Bezel  
A metal bezel is mounted to the chassis front to provide the Dell ID. A lock on the bezel is used to  
protect un-authorized access to system peripherals and the control panel. System status via the LCD is  
viewable even when the bezel is installed.  
III. Hard Drive  
The optional front bezel of the system contains a lock. A locked bezel secures the system hard drives.  
IV. TPM  
The TPM is used to generate/store keys, protect/authenticate passwords, and create/store digital  
certificates. TPM can also be used to enable the BitLocker™ hard drive encryption feature in Windows  
Server® 2008. TPM is enabled through a BIOS option and uses HMAC-SHA1-160 for binding. There will be  
different planar PWA part numbers to accommodate the different TPM solutions. The “Rest of World"  
(ROW) version will have the TPM soldered onto the planar. The other version of the planar (post RTS  
and primarily for use by China) will have a connector for a plug-in module.  
V. Power Off Security  
The control panel is designed such that the power switch cannot be accidentally activated. The lock on  
the bezel secures the switch behind the bezel. In addition, there is a setting in the CMOS setup that  
disables the power button function.  
VI. Intrusion Alert  
A switch mounted on the left riser board is used to detect chassis intrusion. When the cover is opened,  
the switch circuit closes to indicate intrusion to ESM. When enabled, the software can provide  
notification to the customer that the cover has been opened.  
VII. Secure Mode  
BIOS has the ability to enter a secure boot mode via Setup. This mode includes the option to lock out  
the power and NMI switches on the Control Panel or set up a system password. See the 11th generation  
of PowerEdge servers BIOS Specification for details  
l. usb key  
The port on the control panel is for an optional USB key and is located inside the chassis. Some of the  
possible applications of the USB key are:  
• User custom boot and pre-boot OS for ease of deployment or diskless environments  
• USB license keys for software applications like eToken™ or Sentinel Hardware Keys  
Storage of custom logs or scratch pad for portable user defined information (not hot-swappable)  
m. battery  
A replaceable coin cell CR2032 3V battery is mounted on the planar to provide backup power for the  
Real-Time Clock and CMOS RAM on the ICH9 chip.  
n. field Replaceable units (fRu)  
The planar contains a serial EEPROM to contain FRU information including Dell part number, part  
revision level, and serial number. The Advanced Management Enablement Adapter (AMEA) also  
contains a FRU EEPROM. The backplane’s SEP and the power supplies’ microcontroller are also used to  
store FRU data.  
12  
Dell™ PowerEdge™ R710 Technical Guidebook  
section 3. electrical  
a. volatility  
See Appendix A of this Technical Guidebook  
b. ePPiD (electronic Piece Part identication)  
ePPID is an electronic repository for information from the PPID label that is stored in non-volatile RAM.  
The BIOS reports the ePPID information using SMBIOS data structures. ePPID includes the following  
information:  
• Dell part number  
• Part revision level  
• Country of origin  
• Supplier ID code  
• Date code (date of manufacture)  
• Unique sequence number  
stORaGe  
cOmPOnent  
DescRiPtiOn  
lOcatiOn  
bOaRDs  
Planar  
PWA,PLN,SV,DELL,R710  
iDRAC FRU  
SEP  
2.5" x 8' Backplane  
3.5" x 6' Backplane  
3.5" x 4' Backplane  
iDRAC Enterprise  
POWeR suPPlies  
PWA,BKPLN,SV,R710,2.5SASX8  
PWA,BKPLN,SV,R710,3.5SASX6  
PWA,BKPLN,SV,R710,3.5SASX4  
PWA,RSR, SV, DELL,AMEA  
SEP  
SEP  
FRU  
PWR SPLY,885W,RDNT,ASTEC  
PWR SPLY,885W,RDNT,DELTA  
PWR SPLY,598W,RDNT,ASTEC  
PWR SPLY,598W,RDNT,COLDWATT  
PSU Microcontroller  
PSU Microcontroller  
PSU Microcontroller  
PSU Microcontroller  
870W PowerEdge™ PSU  
570W Energy Smart PSU  
stORaGe caRDs  
PERC 6/i Integrated  
PERC 6/E External  
SAS 6/iR Integrated  
ASSY,CRD,PERC6I-INT,SAS,NOSLED  
PWA,CTL,PCIE,SAS,PERC6/E,ADPT  
PWA,CTL,SAS,SAS6/IR,INTG  
FRU  
FRU  
FRU  
Table: ePPID Support list  
Note: The fans do not have any integrated NVRAM. The PPID tables are currently scanned into a database by the system integrator.  
13  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 4. POWeR, theRmal, acOustic  
a. Power efficiencies  
One of the main features of the 11th generation of PowerEdge servers is enhanced power efficiency.  
PowerEdge R710 achieves higher power efficiency by implementing the following features:  
• User-selectable power cap (subsystems will throttle to maintain the specified power cap)  
• Improved power budgeting  
• Accurate inlet temperature  
• PSU / VR efficiency improvements  
• Switching regulators instead of linear regulators  
• Closed loop thermal throttling  
• Increased rear venting / 3D venting  
• PWM fans with an increased number of fan zones and configuration-dependent fan speeds  
• Use of DDR3 memory (lower voltage compared to DDR2, UDIMM support)  
• CPU VR dynamic phase shedding  
• Memory VR static phase shedding  
• Random time interval for system start  
• Allows an entire rack to power on without exceeding the available power  
• BIOS Power/Performance options page  
• Active Power Controller (BIOS-based CPU P-state manager)  
• Ability to power down or throttle memory  
• Ability to disable a CPU core  
• Ability to turn off LOMs or PCIe lanes when not being used  
• Option to run PCIe at Gen1 speeds instead of Gen2  
b. Power supplies  
I. Main Power Supply  
The base redundant system consists of two hot-plug 570W Energy Smart (energy efficient) power  
supplies in a 1+1 configuration. An 870W high-output power supply is also available. The power supplies  
connect directly to the planar.  
There is a power cable to connect between the planar and the backplane. PowerEdge R710 power  
supplies have embedded cooling fans.  
Starting with the 11th generation of PowerEdge servers (R710, R610, T610, M610, and M710), the  
power supplies no longer have a FRU EEPROM. FRU data is now stored in the memory of the PSU  
Microcontroller. Additionally, the PSU Firmware can now be updated by the BMC over the PMBus.  
Power is “soft-switched,” allowing power cycling via a switch on the front of the system enclosure, or  
via software control (through server management functions). In a single power supply configuration,  
the power supply is installed in the PS1 location and a blank module (metal cover) is installed in the  
PS2 location for factory consistency. Electrically, the system can operate with a single power supply in  
either bay.  
14  
Dell™ PowerEdge™ R710 Technical Guidebook  
c. Power supply specications  
ac POWeR suPPly (PeR POWeR suPPly)  
870 Watt (High Output)  
570 Watt (Energy Smart)  
Wattage  
Voltage  
90-264 VAC, autoranging, 47-63Hz  
2968.6 BTU/hr maximum (High Output)  
1944.9 BTU/hr maximum (Energy Smart)  
Heat Dissipation  
Under typical line conditions and over the entire system ambient  
operating range, the inrush current may reach 55A per power supply  
for 10ms or less.  
Maximum Inrush Current  
15  
Dell™ PowerEdge™ R710 Technical Guidebook  
D. environmental specications  
temPeRatuRe  
10° to 35°C (50° to 95°F) with a maximum temperature gradation of  
Operating  
10°C per hour. Note: For altitudes above 2950 feet, the maximum  
operating temperature is derated 1°F/550 ft.  
-40° to 65°C (-40° to 149°F) with a maximum temperature gradation of  
20°C per hour  
Storage  
Relative humiDity  
Operating  
20% to 80% (noncondensing) with a maximum humidity gradation of  
10% per hour  
5% to 95% (noncondensing) with a maximum humidity gradation of  
10% per hour  
Storage  
maximum vibRatiOn  
Operating  
0.26 Grms at 5-350Hz in operational orientations  
1.54 Grms at 10-250Hz in all orientations  
Storage  
maximum shOck  
Half sine shock in all operational orientations of 31G +/- 5% with a pulse  
duration of 2.6 ms +/-10%  
Operating  
Half sine shock on all six sides of 71G +/- 5% with a pulse duration of  
2 ms +/-10%: Square wave shock on all six sides of 27G with velocity  
change @ 235 in/sec or greater  
Storage  
altituDe  
Operating  
Storage  
-16 to 3048 m (-50 to 10,000 ft) Note: For altitudes above 2950 feet, the  
maximum operating temperature is derated 1°F/550 ft.  
-16 to 10,600 m (-50 to 35,000 ft)  
16  
Dell™ PowerEdge™ R710 Technical Guidebook  
e. Power consumption testing  
featuRe  
eneRGy smaRt Psu  
hiGh OutPut Psu  
Dimensions  
L-206.4 mm1 x W-67.5 mm x H-76.5 mm  
Status Indicators  
Integrated Fans  
Fixed Input Plug  
AC Cord Rating  
Input Voltage  
1 x bi-color Light Emitting Diode  
1 x 60 mm  
IEC-C14  
15 Amps @ 120 VAC, 10 Amps @ 240 VAC  
90 – 264 VAC  
Auto-ranging  
Yes  
Line Frequency  
47 – 63Hz  
Maximum Inrush Current  
Hot-Swap Capability  
Output Power  
55 Amps per supply for 10 ms or less  
Yes  
570W  
870W  
Maximum Heat Dissipation  
1944.9 BTU per hour  
2968.6 BTU per hour  
86.9 – 90.5% @ 115 VAC  
88 – 92% @ 230 VAC  
85 – 88% @ 115 VAC  
87 – 90% @ 230 VAC  
Efficiency (20% - 100% Load)  
1 Does not include the power supply handle or ejection tab  
f. maximum input amps  
Max input current (High Output): 12A @ 90 VAC, 6A @ 180 VAC  
Max input current (EnergySmart): 7.8A @ 90 VAC, 3.9A @ 180 VAC  
G. energy smaRt enablement  
The 11th generation of PowerEdge servers implements aspects of Dell’s new Energy Smart strategy.  
Major differences include:  
• Discontinuing Energy Smart-branded servers with limited configurations and instead offering  
Energy Smart components on a portfolio level, such as high capacity and Energy Smart  
power supplies  
• Allowing customers to order either a lowest power footprint configuration or a best  
performance-per-watt configuration  
• Offering Energy Smart selected components such as DIMMs or hard drives, but not “cherry  
picking" or screening individual manufacturers’ components based on energy consumption.  
17  
Dell™ PowerEdge™ R710 Technical Guidebook  
h. acoustics  
The acoustical design of the PowerEdge R710 reflects the following:  
• Adherence to Dell’s high sound quality standards. Sound quality is different from sound power  
level and sound pressure level in that it describes how humans respond to annoyances in sound,  
like whistles, hums, etc. One of the sound quality metrics in the Dell specification is prominence  
ratio of a tone, and this is listed in the table below.  
• Office environment acoustics. Compare the values for LpA in the table below and note that  
they are lower than ambient noise levels of typical office environments.  
• Hardware configurations affect system noise levels. Dell’s advanced thermal control provides  
for optimized cooling with varying hardware configurations. Most typical configurations will  
perform as listed in the table below. However some less typical configurations and components  
can result in higher noise levels. For example, a system configured with a PERC6/E card will be  
approximately twice as loud ( 9 dBA higher) in 23+/-2° C ambient.  
~
• Noise ramp and descent at Bootup. Fan speeds hence noise levels ramp during the boot  
process in order to add a layer of protection for component cooling in the case that the system  
were not to boot properly.  
PowerEdge R710 (2.5" and 3.5" chassis) with RK385 fans (quantity below), 2x 870-W FU096 Power  
Supplies, 2.40 GHz Quad-Core E5530 CPUs (quantity below), 7x 2-GB DIMMs, 1x DVD Drive, Perc 6i  
card, and 4x Hard Disk Drives (type below)  
Acoustical dependence on quantities of fans, CPUs, and Hard Disk Drive type is not strong. The values  
below represent therefore the performance for redundant (5x fans and 2x CPUs) as well as the  
nonredundant (4x fans and 1x CPU) configurations. They also represent performance for 2.5" 10k SAS  
XK112 as well as 3.5" 7.2k SATA NW340 Hard Disk Drives.  
_
+
Condition in 23 2° C ambient  
LwA-UL, bels  
LpA, dBA  
Tones  
Standby  
Idle  
3.1  
18  
No prominent tones  
No prominent tones  
5.5  
39  
Active Hard Disk Drives  
Stressed Processor  
5.5  
5.5  
39  
39  
No prominent tones  
No prominent tones  
Definitions  
Standby: AC Power is connected to Power Supply Units but system is not turned on.  
Idle: Reference ISO7779 (1999) definition 3.1.7; system is running in its OS but no other specific activity.  
Active Hard Drives: An operating mode per ISO7779 (1999) definition 3.1.6; Section C.9 of ECMA-74  
9th ed. (2005) is followed in exercising the hard disk drives.  
Stressed Processor: An operating mode per ISO7779 (1999) definition 3.1.6; SPECPower set to 50%  
loading is used.  
LwA-UL: The upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296 (1988) and  
measured in accordance with ISO7779 (1999).  
LpA: The average bystander position A-weighted sound pressure level calculated per section 4.3 of  
ISO9296 (1988) and measured in accordance with ISO7779 (1999). The system is placed in a  
rack with its bottom at 25-cm from the floor.  
Tones: Criteria of D.5 and D.8 of ECMA-74 9th ed. (2005) are followed to determine if discrete tones are  
prominent. The system is placed in a rack with its bottom at 75-cm from the floor. The acoustic  
transducer is at front bystander position, ref ISO7779 (1999), Section 8.6.2.  
18  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 5. blOck DiaGRam  
Figure: PowerEdge R710 Main Components  
19  
Dell™ PowerEdge™ R710 Technical Guidebook  
1
2
3
4
5
6
7
8
8
9
11  
10  
1. Embedded Network Interface Ports (4)  
2. PCIe Gen2 Riser / Slots  
7. Heat Sink / Processor Socket  
8. DIMM Slots  
3. Broadcom 5709c Network Interface Chip  
4. PCIe Gen2 Riser / Slots  
5. iDRAC6 Enterprise (Optional)  
6. iDRAC6 Express / Lifecycle Controller  
9. Hot plug, redundant fans  
10. Hard drive bay, 6" x 3.5"  
11. Internal SD Module  
(Embedded Hypervisor Optional)  
20  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 6. PROcessORs  
A. Overview / Description  
The Intel 5500 series 2S processor (Nehalem - Efficient Processor (EP)), is the microprocessor designed  
specifically for servers and workstation applications. The processor features quad-core processing to  
maximize performance and performance/watt for data center infrastructures and highly dense  
deployments. The Nehalem-EP 2S processor also features Intel’s Core™ micro-architecture and Intel  
64 architecture for flexibility in 64-bit and 32-bit applications and operating systems.  
The 5500 series 2S processor (Nehalem EP) utilizes a 1366-contact Flip-Chip Land Grid Array (FC-LGA)  
package that plugs into a surface mount socket. PowerEdge R710 provides support for up to two 5500  
series 2S processors (Nehalem EP).  
nehalem-eP 2s PROcessOR  
featuRes  
Cache Size  
Multi-processor Support  
Package  
32KB instruction, 32KB data, 4 or 8MB (shared)  
1-2 CPUs  
LGA1366  
Table: Nehalem-EP Features  
B. Features  
Key features of the 5500 series 2S processor (Nehalem EP) include:  
• Four or two cores per processor  
Two point-to-point QuickPath Interconnect links at up to 6.4 GT/s  
• 1366-pin FC-LGA package  
• 45 nm process technology  
• No termination required for non-populated CPUs (must populate CPU socket 1 first)  
• Integrated three-channel DDR3 memory controller at up to 1333MHz  
• Compatible with existing x86 code base  
• MMX™ support  
• Execute Disable Bit Intel Wide Dynamic Execution  
• Executes up to four instructions per clock cycle  
• Simultaneous Multi-Threading (Hyper-Threading) capability  
• Support for CPU Turbo Mode (on certain SKUs)  
• Increases CPU frequency if operating below thermal, power, and current limits  
• Streaming SIMD (Single Instruction, Multiple Data) Extensions 2, 3, and 4  
• Intel 64 Tecnology for Virtualization  
• Intel VT-x and VT-d Technology for Virtualization  
• Demand-based switching for active CPU power management as well as support for ACPI  
P-States, C-States, and T-States  
C. Supported Processors  
mODel  
sPeeD  
POWeR  
cache  
cORes  
X5570  
X5560  
X5550  
E5540  
2.93GHz  
2.80GHz  
2.66GHz  
2.53GHz  
95W  
95W  
95W  
80W  
8M  
8M  
8M  
8M  
4
4
4
4
21  
Dell™ PowerEdge™ R710 Technical Guidebook  
mODel  
sPeeD  
POWeR  
cache  
cORes  
E5530  
E5520  
L5520  
E5506  
L5506  
E5504  
E5502  
2.40GHz  
2.26GHz  
2.26GHz  
2.13GHz  
2.13GHz  
2.00GHz  
1.86GHz  
80W  
80W  
60W  
80W  
60W  
80W  
80W  
8M  
8M  
8M  
4M  
4M  
4M  
4M  
4
4
4
4
4
4
2
D. Processor Configurations  
Single CPU Configuration  
The PowerEdge R710 is designed such that a single processor placed in the CPU1 socket will function  
normally, however PowerEdge R710 systems require a CPU blank in the CPU2 socket for thermal reasons.  
The system will be held in reset if a single processor is placed in the CPU2 socket.  
Performance Enhancements  
Intel® Turbo Boost Technology  
Intel Xeon® 5500 Series Processor (Nehalem-EP)  
TURBO Freq  
Intel® Turbo Boost  
Technology  
Increases performance by increasing processor  
frequency and enabling faster speeds when  
conditions allow  
Intel® Hyper-Threading  
Technology  
Increases performance for threading applications  
delivering greater throughput and responsiveness  
Cores / Threads  
BASE Freq  
3.20 GHz  
2.93 GHz  
Be n e f i t  
up to 6%†  
for 16 concurrent  
Core Core  
1
0
Co
0
Core Core  
3
16  
2
Co
2
3
(2 socket/HT on)  
software threads  
Normal  
4C Turbo <4C Turbo  
OR  
Core  
0
IDLE  
IDLE IDLE  
3.33 GHz  
2.93 GHz  
up to 10%  
for 2 software  
Co
0
2
IDL
All cores  
operate  
All cores  
(2 socket/HT on)  
threads  
Fewer cores  
operate  
at higher  
frequency  
may operate  
at even higher  
frequencies  
at rated  
frequency  
Improves application responsiveness  
Delivers higher processor frequency on demand  
Higher performance  
on demand  
Higher performance  
for threaded workloads  
mODel  
sPeeD  
POWeR  
cache  
cORes  
X5570  
X5560  
X5550  
E5540  
E5530  
E5520  
L5520  
E5506  
L5506  
E5504  
E5502  
2.93GHz  
2.80GHz  
2.66GHz  
2.53GHz  
2.40GHz  
2.26GHz  
2.26GHz  
2.13GHz  
2.13GHz  
2.00GHz  
1.86GHz  
95W  
95W  
95W  
80W  
80W  
80W  
60W  
80W  
60W  
80W  
80W  
8M  
8M  
8M  
8M  
8M  
8M  
8M  
4M  
4M  
4M  
4M  
4
4
4
4
4
4
4
4
4
4
2
22  
Dell™ PowerEdge™ R710 Technical Guidebook  
CPU Power Voltage Regulation Modules (EVRD 11.1)  
Voltage regulation to the 5500 series 2S processor (Nehalem EP) is provided by EVRD (Enterprise  
Voltage Regulator-Down). EVRDs are embedded on the planar. CPU core voltage is not shared between  
processors. EVRDs support static phase shedding and power management via the PMBus.  
sectiOn 7. memORy  
a. Overview / Description  
The PowerEdge R710 utilizes DDR3 memory providing a high performance, high-speed memory  
interface capable of low latency response and high throughput. The PE R710 supports Registered  
ECC DDR3 DIMMs (RDIMM) or Unbuffered ECC DDR3 DIMMs (UDIMM).  
Key features of the PowerEdge R710 memory system include:  
• Registered (RDIMM) and Unbuffered (UDIMM) ECC DDR3 technology  
• Each channel carries 64 data and eight ECC bits support for up to 96GB of RDIMM memory  
(with twelve 8GB RDIMMs)  
• Support for up to 24GB of UDIMM memory (with twelve 2GB UDIMMs)  
• Support for 1066/1333MHz single- and dual-rank DIMMs  
• Support for 1066MHz quad rank DIMMs  
• Single DIMM configuration only with DIMM in socket A1  
• Support ODT (On Die Termination) Clock gating (CKE) to conserve power when DIMMs  
are not accessed  
• DIMMs enter a low-power self-refresh mode  
• I2C access to SPD EEPROM for access to RDIMM thermal sensors  
• Single Bit Error Correction  
• SDDC (Single Device Data Correction – x4 or x8 devices)  
• Support for Closed Loop  
• Thermal Management on RDIMMs and UDIMMs  
• Multi Bit Error Detection Support for Memory Optimized Mode  
• Support for Advanced ECC mode  
• Support for Memory Mirroring  
b. Dimms supported  
The DDR3 memory interface consists of three channels, with up to two RDIMMs or UDIMMs per  
channel for single-/dual-rank and up to two RDIMMs per channel for quad rank. The interface uses 2GB,  
4GB, or 8GB RDIMMs. 1GB or 2GB UDIMMs are also supported. The memory mode is dependent on how  
the memory is populated in the system:  
Three channels per CPU populated identically:  
Typically, the system will be set to run in Memory Optimized (Independent Channel) mode in  
this configuration. This mode offers the most DIMM population flexibility and system memory  
capacity, but offers the least number of RAS (reliability, availability, service) features.  
• All three channels must be populated identically.  
• Users wanting memory sparing must also populate the DIMMs in this method, but one channel  
is the spare and is not accessible as system memory until it is brought online to replace a failing  
channel.  
• The first two channels per CPU populated identically with the third channel unused  
Typically, two channels operate in Advanced ECC (Lockstep) mode with each other by  
having the cache line split across both channels. This mode provides improved RAS  
features (SDDC support for x8-based memory).  
• For Memory Mirroring, two channels operate as mirrors of each other — writes go to  
both channels and reads alternate between the two channels.  
23  
Dell™ PowerEdge™ R710 Technical Guidebook  
• One channel per CPU populated:  
• This is a simple Memory Optimized mode. Mirroring is not supported.  
The PowerEdge R710 memory interface supports memory demand and patrol scrubbing, single-bit  
correction and multi-bit error detection. Correction of a x4 or x8 device failure is also possible with  
SDDC in the Advanced ECC mode. Additionally, correction of a x4 device failure is possible in the Memory  
Optimized mode. If DIMMs of different speeds are mixed, all channels will operate at the fastest common  
frequency. RDIMMs and UDIMMs cannot be mixed.  
• If memory mirroring is enabled, identical DIMMs must be installed in the same slots across both  
channels.  
• The third channel of each processor is unavailable for memory mirroring.  
• The first DIMM slot in each channel is color-coded with white ejection tabs for ease of  
installation.  
• The DIMM sockets are placed 450 mils (11.43 mm) apart, center-to-center in order to provide  
enough space for sufficient airflow to cool stacked DIMMs.  
• The PE R710 memory system supports up to 18 DIMMs. DIMMs must be installed in each channel  
starting with the DIMM farthest from the processor. Population order will be identified by the  
silkscreen designator and the System Information Label (SIL) located on the chassis cover.  
• Memory Optimized: {1, 2, 3}, {4, 5, 6}, {7, 8, 9}  
• Advanced ECC or Mirrored: {2, 3}, {5, 6}, {8, 9}  
• Quad Rank or UDIMM: {1, 2, 3}, {4, 5, 6}, {7, 8, 9}  
c. speed  
Memory Speed Limitations  
The memory frequency is determined by a variety of inputs:  
• Speed of the DIMMs  
• Speed supported by the CPU  
• Configuration of the DIMMs  
24  
Dell™ PowerEdge™ R710 Technical Guidebook  
The table below shows the memory populations and the maximum frequency achievable for that  
configuration.  
Dimm tyPe  
Dimm 0  
Dimm 1  
Dimm 2  
# Of Dimms  
800  
1066  
1333  
SR  
DR  
SR  
SR  
DR  
SR  
DR  
QR  
SR  
SR  
DR  
QR  
QR  
QR  
SR  
SR  
SR  
DR  
1
1
UDIMM  
SR  
DR  
DR  
2
2
2
1
1
1
SR  
DR  
DR  
SR  
DR  
QR  
SR  
SR  
DR  
DR  
2
2
2
2
2
2
3
3
3
3
RDIMM  
SR  
DR  
DR  
DR  
Note: For QR mixed with an SR/DR DIMM, the QR needs to be in the white DIMM connector. There is no requirement in the order of SR and DR DIMMs.  
Supported  
Not Supported  
NOTE: For Quad Rank DIMMs mixed with Single- or Dual-Rank DIMMs, the QR DIMM needs to be in the slot with the white ejection tabs (the first DIMM slot in each channel).  
There is no requirement for the order of SR and DR DIMMs  
25  
Dell™ PowerEdge™ R710 Technical Guidebook  
NHM-EP Platform Memory Overview  
• Platform capability (18 DIMMs):  
– Up to 3 channels per CPU  
– Up to 3 DIMMS per channel  
1
Up to 3  
channels  
per CPU  
NHM-EP  
NHM-EP  
2
3
• Memory Types Supported:  
– DDR 1333, 1066, and 800  
– Registered (RDIMM) and unbuffered (UDIMM)  
– Single-rank (SR), dual-rank (DR), quad-rank (QR)  
1 2 3  
Up to 3  
DIMMs per  
Channel  
• System memory Speed (i.e. the speed at which the memory is  
actually running) is set by BIOS depending on:  
– CPU capability  
– DIMM type(s) used (memory speed, U/RDIMM, SR/DR/QR)  
– DIMM populated per channel  
• All channels in a system will run at the fastest common frequency  
Memory Population Scenarios  
CPUs  
10.6 GB/s  
• Maximum B/W:  
– DDR3 1333 across 3 channels  
10.6  
– 1 DPC (6 DIMMs)  
– Max capacity: 48 GB+  
E5550  
and above  
CPU  
CPU  
CPU  
CPU  
10.6  
8.5 GB/s  
8.5  
• Balanced Performance:  
– DDR3 1066 across 3 channels  
– Up to 2 DIMMs per Channel  
(DPC) (12 DIMMs)  
E5520  
and above  
CPU  
8.5  
– Max capacity: 96 GB+  
6.4 GB/s  
6.4  
• Maximum capacity:  
– DDR3 800 across 3 channels  
– Up to 3 DPC (18 DIMMs total)  
– Max capacity: 144 GB+  
All  
NHM-EP  
SKUs  
CPU  
6.4  
• RAS capabilities:  
Mirroring  
CPU  
Lockstep  
Channel  
0 & 1  
mirror  
Channel  
0 & 1  
operate in  
lockstep  
CPU  
each other  
Channel  
Channel  
2 unused  
2 unused  
26  
Dell™ PowerEdge™ R710 Technical Guidebook  
D. slots / Risers  
The PowerEdge R710 has 18 DIMM slots for memory. It does not have any riser cards for DIMM population.  
e. supported configurations  
memORy sOckets  
sinGle PROcessOR  
Dual PROcessOR  
RDimm  
memORy  
mODule  
size  
memORy  
mODe  
1
2
3
Physical available Physical available  
memORy  
(Gb)  
memORy  
(Gb)  
memORy  
(Gb)  
memORy  
(Gb)  
4
5
6
x
2
4
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
4
6
8
x
x
x
x
x
x
x
x
x
x
12  
2GB  
All  
All  
x
x
x
4
8
x
x
x
x
8
16  
24  
8
12  
4
x
x
8
16  
24  
16  
32  
48  
16  
32  
48  
32  
64  
96  
8
12  
8
4GB  
All  
All  
All  
All  
x
x
x
x
x
x
x
16  
24  
8
x
x
16  
24  
16  
32  
48  
4
8GBa  
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
2
4
4
8
4
8
None  
None  
None  
2GB  
4GB  
8GB  
x
x
x
8
16  
16  
32  
32  
64  
8
8
16  
16  
32  
16  
16  
32  
8
16  
Table: RDIMM Memory Configurations (Each Processor)  
27  
Dell™ PowerEdge™ R710 Technical Guidebook  
memORy  
sinGle  
Dual PROcessOR  
sOckets  
PROcessOR  
uDimm  
memORy  
mODule  
size  
memORy  
mODe  
1
2
3
Physical available Physical available  
memORy  
(Gb)  
memORy  
(Gb)  
memORy  
(Gb)  
memORy  
(Gb)  
4
5
6
x
1
2
x
x
x
x
x
x
x
x
x
x
x
2
3
4
6
1GB  
All  
All  
All  
All  
x
x
x
x
x
x
x
x
4
6
2
8
x
x
12  
4
x
x
x
x
4
6
8
12  
8
x
2GB  
12  
16  
24  
x
x
x
x
x
x
None  
x
2
All All  
1GB  
All  
x
x
x
x
4
None  
x
x
4
2GB  
All  
All  
All  
x
x
x
x
x
x
x
x
x
x
x
x
8
None  
2
4
4
8
1
4
8
2
4
4
8
1GB  
x
x
2
2
4
None  
8
2GB  
x
x
16  
Table: UDIMM Memory Configurations (Each Processor)  
a When available  
b Requires x4- or x8-based memory modules  
f. mirroring  
The system supports memory mirroring if identical memory modules are installed in the two channels  
closest to the processor (memory is not installed in the farthest channel). Mirroring must be enabled in  
the System Setup program. In a mirrored configuration, the total available system memory is one-half of  
the total installed physical memory.  
G. advanced ecc (lockstep) modes  
In this configuration, the two channels closest to the processor are combined to form one 128-bit channel.  
This mode supports Single Device Data Correction (SDDC) for both x4- and x8-based memory modules.  
Memory modules must be identical in size, speed, and technology in corresponding slots.  
h. Optimizer (independent channel) mode  
In this mode, all three channels are populated with identical memory modules. This mode permits a larger  
total memory capacity but does not support SDDC with x8-based memory modules. A minimal single-  
channel configuration of 1GB memory modules per processor is also supported in this mode.  
28  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 8. chiPset  
a. Overview / Description  
The PowerEdge R710 planar incorporated the Intel 5520 chipset (code named Tylersburg) for I/O and  
processor interfacing. Tylersburg is designed to support Intel's 5500 series processors (code named  
Nehalem-EP), QPI interconnect, DDR3 memory technology, and PCI Express Generation 2. The  
Tylersburg chipset consists of the Tylersburg-36D IOH and ICH9.  
The Intel 5520 chipset (code named Tylersburg) I/O Hub (IOH)  
The planar uses the The Intel® 5520 chipset (code named Tylersburg) I/O Hub (IOH)-36D IOH to provide  
a link between the 5500 series 2S processor (Nehalem EP) and I/O components. The main components  
of the IOH consist of two full-width QuickPath Interconnect links (one to each processor), 36 lanes of  
PCI Express Gen2, a x4 Direct Media Interface (DMI), and an integrated IOxAPIC.  
IOH QuickPath Interconnect (QPI)  
The QuickPath Architecture consists of serial point-to-point interconnects for the processors and the  
IOH. The PowerEdge R710 has a total of three QuickPath Interconnect (QPI) links: one link connecting  
the processors and links connecting both processors with the IOH. Each link consists of 20 lanes  
(full-width) in each direction with a link speed of up to 6.4 GT/s. An additional lane is reserved for a  
forwarded clock. Data is sent over the QPI links as packets.  
The QuickPath Architecture implemented in the IOH and CPUs features four layers. The Physical layer  
consists of the actual connection between components. It supports Polarity Inversion and Lane Reversal  
for optimizing component placement and routing. The Link layer is responsible for flow control and the  
reliable transmission of data. The Routing layer is responsible for the routing of QPI data packets. Finally,  
the Protocol layer is responsible for high-level protocol communications, including the implementation of  
a MESIF (Modify, Exclusive, Shared, Invalid, Forward) cache coherence protocol.  
29  
Dell™ PowerEdge™ R710 Technical Guidebook  
Intel Direct Media Interface (DMI)  
The DMI (previously called the Enterprise Southbridge Interface) connects the Tylersburg IOH with the  
Intel I/O Controller Hub (ICH). The DMI is equivalent to a x4 PCIe Gen1 link with a transfer rate of 1 Gb/s  
in each direction.  
PCI Express Generation 2  
PCI Express is a serial point-to-point interconnect for I/O devices. PCIe Gen2 doubles the signaling bit  
rate of each lane from 2.5 Gb/s to 5 Gb/s. Each of the PCIe Gen2 ports are backwards-compatible with  
Gen1 transfer rates.  
In the Tylersburg-36D IOH, there are two x2 PCIe Gen2 ports (1Gb/s) and eight x4 PCIe Gen2 ports (2  
Gb/s). The x2 ports can be combined as a x4 link; however, this x4 link cannot be combined with any of  
the other x4 ports. Two neighboring x4 ports can be combined as a x8 link, and both resulting x8 links  
can combine to form a x16 link.  
Intel I/O Controller Hub 9 (ICH9)  
ICH9 is a highly integrated I/O controller, supporting the following functions:  
• Six x1 PCIe Gen1 ports, with the capability of combining ports 1-4 as a x4 link  
• These ports are unused on the PowerEdge R710  
• PCI Bus 32-bit Interface Rev 2.3 running at 33MHz  
• Up to six Serial ATA (SATA) ports with transfer rates up to 300 MB/s  
The PowerEdge R710 features two SATA port for optional internal optical drive or tape backup  
• Six UHCI and two EHCI (High-Speed 2.0) USB host controllers, with up to twelve USB ports  
The PowerEdge R710 has eight external USB ports and two internal ports dedicated for UIPS.  
Refer to the 11th generation of PowerEdge servers Hardware/BIOS Specification for the USB  
assignments for each platform  
• Power management interface (ACPI 3.0b compliant)  
• Platform Environmental Control Interface (PECI)  
• Intel Dynamic Power Mode Manager  
• I/O interrupt controller  
• SMBus 2.0 controller  
• Low Pin Count (LPC) interface to Super I/O, Trusted Platform Module (TPM), and SuperVU  
• Serial Peripheral Interface (SPI) support for up to two devices  
• The PowerEdge R710’s BIOS is connected to the ICH using SPI  
30  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 9. biOs  
a. Overview / Description  
The PowerEdge R710 BIOS is based on the Dell BIOS core, and supports the following features:  
• Nehalem-EP 2S Support  
• Simultaneous Multi-Threading (SMT) support  
• CPU Turbo Mode support  
• PCI 2.3 compliant  
• Plug n’ Play 1.0a compliant  
• MP (Multiprocessor) 1.4 compliant  
• Boot from hard drive, optical drive, iSCSI drive, USB key, and SD card  
• ACPI support  
• Direct Media Interface (DMI) support  
• PXE and WOL support for on-board NICs  
• Memory mirroring and spare bank support  
• SETUP access through <F2> key at end of POST  
• USB 2.0 (USB boot code is 1.1 compliant)  
• F1/F2 error logging in CMOS  
• Virtual KVM, CD, and floppy support  
• Unified Server Configurator (UEFI 2.1) support  
• Power management support including DBS, power inventory and multiple power profiles  
The PowerEdge R710 BIOS does not support the following:  
• Embedded Diagnostics (embedded in MASER)  
• BIOS language localization  
• BIOS recovery after bad flash (but can be recovered from iDRAC6 Express)  
b. supported acPi states  
Advanced Configuration and Power Interface – A standard interface for enabling the operating system  
to direct configuration and power management.  
The Nehalem processor supports the following C-States: C0, C1, C1E, C3, and C6. R710 will support all of  
the available C-States.  
The PowerEdge R710 will support the available P-States as supported by the specific Nehalem processors:  
PROc  
stanDaRD  
tDP  
qDf #  
fRequency  
lfm tDP  
P-state  
nOtes  
numbeR  
1.60  
1.73  
Pmin+0  
Pmin+1  
Pmin+2  
Pmin+3  
Pmin+4  
Pmin+4  
Pmin+5  
Pmin+5  
Pmin+6  
E5502  
E5504  
L5506  
E5506  
L5520  
E5520  
E5530  
Q1G8  
Q1GM  
Q1HG  
Q1GL  
Q1GN  
Q1GR  
Q1GK  
1.86  
2.00  
2.13  
80  
80  
60  
80  
60  
80  
80  
75  
D-0  
D-0  
D-0  
D-0  
D-0  
D-0  
D-0  
75  
52  
75  
52  
75  
75  
2.13  
2.26  
2.26  
2.40  
31  
Dell™ PowerEdge™ R710 Technical Guidebook  
PROc  
stanDaRD  
tDP  
qDf #  
fRequency  
lfm tDP  
75  
P-state  
nOtes  
numbeR  
E5540  
X5550  
X5560  
X5570  
W5580  
Q1G2  
Q1GJ  
Q1GF  
Q1G9  
Q1G6  
2.53  
2.67  
2.80  
2.93  
3.20  
80  
95  
95  
95  
130  
Pmin+7  
Pmin+8  
Pmin+9  
Pmin+10  
Pmin+12  
D-0  
D-0  
D-0  
D-0  
D-0  
75  
75  
75  
98  
Table: Nehalem P-State Projections  
C. I2C (Inter-Integrated Circuit)  
What is I2C? A simple bi-directional 2-wire bus for efficient inter-integrated circuit control. All I2C-bus  
compatible devices incorporate an on-chip interface which allows them to communicate directly with  
each other via the I2C-bus. This design concept solves the many interfacing problems encountered  
when designing digital control circuits. These I2C devices perform communication functions between  
intelligent control devices (e.g., microcontrollers), general-purpose circuits (e.g., LCD drivers, remote  
I/O ports, memories), and application-oriented circuits.  
The PowerEdge R710, BIOS accesses the I2C through the ICH9 (Intel I/O Controller Hub 9). There are two  
MUXes on ICH9’s I2C bus.  
• One MUX (U_ICH_SPD) controls the DIMM SPDs through four split segments  
• The other MUX (U_ICH_MAIN) controls the clock buffers, TOE, USB Hub through four split  
segments.  
BIOS controls both the MUXes through the two select lines using GPIO pins.  
Clock chip, USB hub, and the front panel EEPROM device addresses are located on the IOH I2C bus.  
sectiOn 10. embeDDeD nics / lan On mOtheRbOaRD (lOm)  
a. Overview / Description  
Embedded Gigabit Ethernet Controllers with TCP Offload Engine (TOE) support  
Two embedded Broadcom 5709C dual-port LAN controllers are on the R710 planar as independent  
Gigabit Ethernet interface devices. The following information details the features of the LAN devices.  
• x4 PCI Express Gen2 capable interface  
• The PowerEdge R710 operates this controller at Gen1 speed  
• Integrated MAC and PHY 3072x18 Byte context memory  
• 64 KB receive buffer  
• TOE (TCP Offload Engine)  
• iSCSI controller (enabled through an optional hardware key)  
• RDMA controller (RNIC) (enabled post-RTS through an optional hardware key)  
• NC-SI (Network Controller-Sideband Interface) connection for manageability  
• Wake-On-LAN (WOL)  
• PXE 2.0 remote boot  
• iSCSI boot  
• IPv4 and IPv6 support  
• Bare metal deployment support  
32  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 11. i/O slOts  
a. Overview / Description  
The PowerEdge R710 requires two PCI Express risers: Riser 1 and Riser 2. Each riser connects to the  
planar through an x16 PCI Express connector.  
• Riser 1 consists of two x4 slots and a third x4 slot dedicated for internal SAS storage through  
the PERC 6i or SAS 6/iR.  
• The default Riser 2 consists of two x8 PCI Express connectors.  
• There is also an optional x16 Riser 2 that supports one x16 PCI Express card.  
To ensure proper cooling, no more than two of the four expansion cards can have a power consumption  
of greater than 15W (up to 25W maximum each), not including the integrated storage controller.  
The system does not support hot-plug or hot-removal of PCI Express cards.  
The table below provides a guide for installing expansion cards to ensure proper cooling and mechanical  
fit. The expansion cards with the highest priority should be installed first using the slot priority indicated.  
All other expansion cards should be installed in card priority and slot priority order.  
slOt  
max  
25W  
caRD  
caRD tyPe  
PRiORity  
PRiORity  
allOWeD  
caRD?  
1
PERC 5/E controller  
PERC 6/E  
1, 3, 4  
3, 4, 1  
3, 4, 1, 2  
3, 4, 1  
2, 1  
2
2
Y
Y
2
3
4
5
6
10Gb NIC  
2
Y
All other Dell storage cards  
All other NICs  
2
Y
4a  
4a  
Nb  
Nb  
Non-Dell storage cards  
1, 2  
a Maximum of 2 of any card whose maximum power exceeds 15w  
b Refer to the expansion card’s documentation to determine if the maximum power exceeds 15w  
33  
Dell™ PowerEdge™ R710 Technical Guidebook  
POWeReDGe R710  
PCI Express Gen2 Slots  
Slot 1: Half-Length (6.6" Factory Installation) / Full-Height (x8 connector), x4 link width  
Slot 2: Full-Length (12.2" Factory Installation) / Full-Height (x8 connector), x8 link width  
Slot 3: Full-Length (12.2" Factory Installation) / Full-Height (x8 connector), x8 link width  
Slot 4: Half-Length (6.6" Factory Installation) / Full-Height (x8 connector), x4 link width  
Slot 5: Half-Length (6.6" Factory Installation) / Full-Height (x8 connector), x4 link width  
Card  
Priority  
PCIe Link  
Width  
Slot  
Priority  
Max  
Cards  
Category  
Description  
Dell PN  
Internal Storage  
(Integrated Slot)  
T95  
4J  
1
Dell™ PERC 6/i Integrated (Sled)  
Gen1 x8  
Gen1 x8  
Gen1 x8  
Gen1 x8  
Gen1 x8  
Gen1 x8  
Integrated  
Integrated  
Slot 4, 51  
1
Internal Storage  
(Integrated Slot)  
YK8  
38  
2
3
4
5
6
Dell SAS 6/iR Integrated (Sled)  
1
External Storage  
Controller  
*Dell PERC 5/E Adapter  
(Test only, no factory install)  
GP2  
97  
22  
22  
22  
2
External Storage  
Controller  
*Dell PERC 6/E Adapter  
(512MB)  
Slot 3, 2,  
5, 4, 1  
J15 5F  
External Storage  
Controller  
*Dell PERC 6/E Adapter  
(256MB)  
F98  
9F  
Slot 3, 2,  
5, 4, 1  
*Intel 10GBase-T Copper Single  
Port NIC (Copperpond)  
XR9  
97  
Slot 4, 5, 1,  
2, 3  
10Gb NIC  
10Gb NIC  
10Gb NIC  
*Broadcom BCM57710  
10GBase-T Copper Single Port  
NIC (Quiver)  
RK3  
75  
Slot 4, 5, 1,  
2, 3  
7
Gen1 x8  
2
Intel® 10GBase-SR Optical  
Single Port NIC (BelleFontaine)  
RN  
219  
Slot 4, 5, 1,  
2, 3  
8
9
Gen1 x8  
Gen1 x8  
Gen1 x8  
Gen2 x4  
Gen2 x4  
2
22  
22  
5
External Storage  
Controller  
M7  
78G  
Slot 3, 2,  
4, 5, 1  
*Dell SAS 5/E Adapter  
Internal Tape  
Controller  
Dell SAS 5/iR Adapter  
(for internal tape only)  
UN  
939  
Slot 3, 2,  
4, 5, 1  
10  
11  
Fibre Channel  
8 HBA  
Emulex LPe12002 FC8  
Dual-Channel HBA  
C85  
6M  
Slot 4, 5, 1,  
2, 3  
Fibre Channel  
8 HBA  
Emulex LPe12000 FC8  
Single-Channel HBA  
C85  
5M  
Slot 4, 5, 1,  
2, 3  
12  
5
1 Thermal testing to determine if the PERC5 can be installed in other slots is pending.  
2 A maximum of 2 nternal/external storage controllers (Dell PERC and SAS cards) are allowed in the system in addition to the integrated storage controller.  
34  
Dell™ PowerEdge™ R710 Technical Guidebook  
b. Pci express Risers  
The two PowerEdge R710 PCI Express risers provide up to four expansion slots and one internal slot  
as follows:  
Two x8 and two x4 PCI Express Gen2 slots, connected to the IOH  
• One x4 PCI Express Gen1 slot for internal storage, connected to the IOH  
• Support for three full-height 9.5" long PCI Express cards and one full-height bracket, low-profile  
PCB PCI Express card  
• Support for field upgrading one slot (on the center riser) to a full-length 12.2" PCI Express card  
• System supports 25W maximum power for the first two cards and 15W for the third and  
fourth cards  
• The lower power support on the third and fourth cards is due to system thermal limitations  
• An optional x16 riser to accommodate interface cards for external GPU boxes that supports a  
maximum power of 25W. Use of this riser reduces the number of PCI Express slots from four  
to three  
c. additional Riser Restrictions  
• The riser connectors on the planar do not support plugging in a standard PCI Express card. Do  
not attempt this for troubleshooting.  
Two PowerEdge R710 risers must be installed or the system will not power up.  
D. x16 express card specications  
The PowerEdge R710 supports x16 cards that meet the following requirements:  
• Standard height (4.376")  
• Maximum length of 9.5" (Half-length cards are 6.6"; Full-length cards are 12.283")  
• x16 cards can only plug into the optional PowerEdge R710 x16 left riser  
• Support for full bandwidth of x16 Gen2 link  
• No support for hot-plug or hot-removal  
• Maximum power of 25W  
• The PowerEdge R710 provides +12V, +3.3V, and +3.3Vaux in accordance with Power Supply Rail  
Requirements (Table 4-1 of PCIe Card Electromechanical Spec, Rev 2.0)  
• The PowerEdge R710 x16 slot is not compliant with the PCI Express x16 Graphics  
150W-ATX Specification  
• x16 cards must be compliant with the PCI Express Card Electromechanical Specification Rev 2.0  
• x16 cards must only occupy the space of one slot. Cards that occupy the space of two slots are  
not supported  
• The x16 card is limited to 25W initial start-up power until it is configured as a high-power  
device. If no value is set for the Slot Power Limit, the card is limited to 25W. The card must then  
either scale down to 25W or disable operation per PCI Express Base Spec Rev 2.0  
• The x16 card must be able to support a maximum operating temperature of 55°C as defined in  
the Dell PCI Environmental Spec and the PCI Express Card Electromechanical Spec. The  
PowerEdge R710 provides a minimum transverse air velocity of 100 LFM (linear feet per minute)  
to the x16 card.  
e. boot Order  
PCIe scan order (from the BIOS HW spec v1.0)  
IOH port 1,2 (PCI Express Gen1 x4) – Broadcom BCM5709C Gigabit Embedded NIC #1  
IOH port 3 (PCI Express Gen1 x4) – Broadcom BCM5709C Gigabit Embedded NIC #2  
IOH port 4 in Bluefish or ICH9 port1-4 in Thidwick (PCI Express Gen1 x4) – Integrated PERC6i or SAS6i  
on the Riser 1  
IOH port 5 (PCI Express Gen2 x4) – Slot 2 on Riser 1  
IOH port 6 (PCI Express Gen2 x4) – Slot 1 on Riser 1  
IOH port 7/8 (PCI Express Gen2 x8) – Slot 3 on Riser 2  
IOH port 9/10 (PCI Express Gen2 x8) – Slot 4 on Riser 2  
For PCI-e X16 optional left riser, IOH port 7,8,9,10 are combined into one x16 PCI-e slot.  
35  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 12. stORaGe  
a. Overview / Description  
The PowerEdge R710 supports three different backplanes to support different hard drive configurations:  
six 3.5" hard drives, four 3.5" hard drives, or eight 2.5" hard drives.  
On each backplane are two LED indicators per drive slot with one or two mini-SAS x4 cable connectors  
for connecting the backplane to the integrated SAS 6/iR or PERC 6i, and a power connector to connect  
to the planar. Both Serial Attached SCSI (SAS) and Serial ATA (SATA) hard drives are supported. For  
SAS/SATA mixing, two SAS drives are supported with the 3.5" backplane.  
b. Drives  
I. Internal Hard Disk drives  
The PowerEdge R710 supports up to eight 2.5" or six 3.5" hard disk drives.  
• Support for 15,000 rpm 3.5" SAS drives  
• Support for 10,000 and 15,000 rpm 2.5" SAS drives  
• Support for 7,200 rpm 3.5" Near Line SAS drives  
• Support for 7,200 rpm 3.5" and 2.5" Enterprise SATA drives  
• Support for 7,200 rpm 3.5" and 2.5" SATAu drives  
• For SAS/SATA mixing, two SAS and up to six SATA drives are possible  
• A pair of SAS drives must be installed in slots 0 and 1  
• One mixed 2.5" and 3.5" hard drive configuration is allowed:  
• A pair of 2.5" 10k rpm SAS drives must be installed with an adapter in a 3.5" hard drive  
carrier in drive slots 0 and 1  
• The remaining hard drives must be 3.5" hard drives and must be either all SAS or all  
SATA  
• Support for 25 and 50GB 2.5" solid state drives at RTS (additional solid state drive support is  
Post RTS)  
• SSDs require the PERC 6/i Integrated storage controller and cannot be mixed with any other  
type of hard drive  
2.5 HDDs  
2.5" Enterprise SATA 7.2K HDs  
2.5" SAS 10K HDs:  
160GB, 250GB, and 500GB  
73GB, 146GB, and 300GB  
2.5" entry 10K SAS in 3.5" HDD carrier  
2.5" SAS 15K HDs  
73GB and 146GB  
2.5" Enterprise SATA SSD  
2.5" SSD  
25GB, 50GB, and 100GB  
25GB and 50GB  
3.5 HDDs  
160GB, 250GB, 500GB, 750GB, and  
1,000GB  
Support for 3.5" Enterprise SATA 7.2K:  
Support for 3.5" Enterprise SATAu 7.2K:  
500GB SATAu, 750GB SATAu, and  
1 ,000GB SATAu  
Support for 3.5" Green Enterprise SATA 5.4K  
Support for 3.5" Near Line SAS 7.2K  
Support for 3.5" SAS 15K HDs:  
1,000GB  
500GB, 750GB, and 1,000GB  
146GB, 300GB, and 450GB  
Table: R710 supported HDD matrix  
36  
Dell™ PowerEdge™ R710 Technical Guidebook  
For mixed SAS/SATA configurations, SAS drives must be installed as a pair in drive slots 0 and 1.  
One mixed 2.5" and 3.5" hard drive configuration is allowed: a pair of 2.5" 10k rpm SAS drives can be  
installed with an adapter in a 3.5" hard drive carrier in drive slots 0 and 1. The remaining hard drives must  
be 3.5" hard drives and must be either all SAS or all SATA.  
POWeReDGe  
R710  
4
4
4
4
4
4
4
4
4
Platforms  
All 2.5" HDD SAS (or) SATA  
All 2.5" SSD***  
Mixed SSD/SAS**  
All 3.5" HDD SAT (or) SATA  
Mixed SAS/SATA*  
2.5" SAS in 3.5" HDD Carrier (RTS+)  
2.5" SAS HDD in 3.5" HDD Carrier + 3.5" SATA HDDs (Mixed SAS)  
2.5" SAS HDD in 3.5" HDD Carrier + 3.5" SATA HDDs (Mixed SAS/SATA)*  
• SAS HDDs should be in slots 0 & 1 and min/max number of SAS HDDs is 2, rest will be SATA  
HDDs and min/max number of SATA HDDs depends on the configuration.  
• **No maximum for SAS HDD’s combined with SSD  
• ***SSD Support requires PERC 6/i  
20GB and 50GB solid state drives (SSD) support will be supported at RTS  
II. Hard Disk Drive Carriers  
Hard drives must use the Dell 2.5" and the 3.5" Hard Drive Disk Carriers.  
Figure: 2.5" HDD Carrier  
III. Empty Drive Bays  
For the slots that are not occupied by drives, a carrier blank is provided to maintain proper cooling,  
maintain a uniform appearance to the unit, and provide EMI shielding.  
37  
Dell™ PowerEdge™ R710 Technical Guidebook  
IV. Diskless Configuration Support  
The system supports diskless configuration with no storage controller (SAS 6/iR or PERC 6i) installed in  
the system. A 2.5" HDD backplane is still installed in this configuration.  
V. Hard Drive LED Indicators  
Each disk drive carrier has two LED indicators visible from the front of the system. One is a green LED  
for disk activity and the other is a bicolor (green/amber) LED for status information. The activity LED is  
driven by the disk drive during normal operation. The bicolor LED is controlled by the SEP device on the  
backplane. Both LEDs are used to indicate certain conditions under direction of a storage controller.  
c. RaiD configurations  
PowerEdge R710 Factory Configuration Summary  
nOn-mixeD  
DRives, all  
sata OR  
mixeD sas/ sata  
min 2xsas+1xsata  
2.5": MAx 2xsas + 6xsata  
cOnfiG  
tyPe  
all sas  
3.5": MAx 2xsas + 6xsata  
cOnfiGs  
DescRiPtiOn  
min  
max  
hDD  
min  
max  
hDD  
hDD  
hDD  
Integrated  
SAS/SATA No RAID  
(SAS 6/iR)  
2.5"=1  
3.5"=1  
2.5"=8  
3.5"=8  
SAS/SATA  
(No RAID)  
0
1
MSS  
Integrated  
SAS/SATA RAID 0  
(SAS 6/iR, PERC6/I)  
2.5"=1*  
3.5"=1*  
2.5"=8  
3.5"=8  
MSSR0  
MSSR1  
MSSR5  
MSSR6  
MSSR10  
N/A  
N/A  
N/A  
N/A  
Integrated  
SAS/SATA RAID 1  
(SAS 6/iR, PERC6/I)  
2.5"=2  
3.5"=2  
2.5"=2  
3.5"=2  
2
3
4
5
Integrated  
SAS/SATA RAID 5  
(PERC 6/i)  
2.5"=3  
3.5"=3  
2.5"=8  
3.5"=8  
Integrated  
SAS/SATA RAID 6  
(PERC 6/i)  
2.5"=4  
3.5"=4  
2.5"=8  
3.5"=8  
SAS/SATA  
(RAID)  
Integrated  
SAS/SATA RAID 10  
(PERC 6/i)  
2.5"=4  
3.5"=4  
2.5"=8  
3.5"=8  
Integrated  
SAS/SATA RAID  
1/RAID 1  
2.5"=2+2 2.5"=2+2  
3.5"=2+2 3.5"=2+2  
6
MSSR1R1  
(SAS 6/iR, PERC 6/i)  
Integrated  
SAS/SATA RAID  
1/RAID 5 (PERC 6/i)  
2.5  
3.5  
"
"
=2+3 2.5"=2+6  
=2+3 3.5"=2+6  
7
8
MSSR1R5  
MSS-X  
Integrated  
SAS/SATA No RAID  
(SAS 6/iR)  
2.5"=3  
3.5"=3  
2.5"=6  
3.5"=6  
SAS/SATA  
(No RAID)  
38  
Dell™ PowerEdge™ R710 Technical Guidebook  
nOn-mixeD  
DRives, all  
sata OR  
mixeD sas/ sata  
min 2xsas+1xsata  
2.5": MAx 2xsas + 6xsata  
cOnfiG  
cOnfiGs  
tyPe  
all sas  
3.5": MAx 2xsas + 6xsata  
DescRiPtiOn  
min  
max  
hDD  
min  
max  
hDD  
hDD  
hDD  
Integrated  
SAS/SATA RAID  
1/RAID 1  
2.5"=2+2  
3.5"=2+2  
2.5"=2+2  
3.5"=2+2  
9
MSSR1R1- X  
(SAS 6/iR, PERC 6/i)  
SAS/SATA  
(RAID)  
Integrated  
SAS/SATA RAID  
1/RAID 5  
2.5"=2+3  
2.5"=2+6  
10 MSSR1R5-X  
3.5"=2+3  
3.5"=2+6  
(PERC 6/i)  
Integrated SSD  
RAID 1 (PERC 6/i) 3.5"=N/A 3.5"=N/A  
2.5"=2  
2.5"=2  
11  
12  
13  
MSSR1  
MSSR5  
MSSR10  
N/A  
N/A  
N/A  
Integrated SSD 2.5"=3 2.5"=  
SSD  
(RAID)  
RAID 5 (PERC 6/i) 3.5"=N/A 3.5"=N/A  
Integrated SSD 2.5"=4 2.5"=8  
RAID 10 (PERC 6/i) 3.5"=N/A 3.5"=N/A  
Integrated  
SSD/SAS RAID  
1/RAID 5  
2.5"=2+3  
3.5"=N/A  
2.5"=2+6  
3.5"=N/A  
SSD/SAS  
(RAID)  
14 MSSR1R5-X  
(PERC 6/i)  
* Minimum of 1 hard drive for PERC6i ; and minimum of 2 for SAS6iR.  
D. storage controllers  
I. SAS 6/iR  
The PowerEdge R710 internal SAS 6/iR HBA is an expansion card that plugs into a dedicated PCI  
Express x8 slot (only four lanes wired). It incorporates two four-channel SAS IOCs for connection to  
SAS/SATA hard disk drives. It is designed in a form factor that allows the same card to be used in R610  
and T610.  
39  
Dell™ PowerEdge™ R710 Technical Guidebook  
II. PERC 6i  
For customers who want a hardware RAID solution, the PERC 6i is an option. The PERC 6i uses the LSI  
1078 ROC (RAID on Chip) processor with a PCI Express host interface and DDR2 memory. A battery is  
also available for backup.  
R710  
Pcie  
Pcie  
i/O  
PRODuct  
usaGe  
slOt  
RaiD  
bbu  
suPPORt  
cOn  
bRacket  
cOn  
0, 1,  
5, 6,  
10, 50, Yes  
and  
60  
Internal  
Backplane  
Storage  
PERC 6/i  
Integrated  
Storage  
slot  
x4 int  
x4 int  
Yes, Max 1  
x8  
No  
(HDD, SSD)  
Yes, Max 2  
(MD1000  
SAS/SATA Pompano  
0, 1,  
5, 6,  
10, 50, TBBU  
and  
60  
External  
PERC 6/E  
Adapter  
PCIe  
slot  
x4 ext  
x4 ext  
x8  
x8  
Yes  
Yes  
Storage  
& MD1020  
Ridgeback)  
Yes, Max 2  
(MD1000,  
Pompano,  
& MD1020  
Ridgeback)  
External  
Legacy  
Storage  
PERC 5/E  
Adapter  
PCIe  
slot  
x4 ext 0, 1, 5,  
x4 ext 10, 50  
TBBU  
Internal  
Backplane  
Storage  
(No tape  
or SSD  
SAS 6/iR  
Integrated  
Storage  
slot  
x4 int  
0, 1  
Yes, Max 1  
x8  
x8  
No  
No  
No  
x4 int  
support)  
External  
SAS (DAS, Yes, Max 2  
Tape)  
SAS 5/E  
Adapter  
PCIe  
slot  
x4 ext  
none  
Yes  
x4 ext  
Internal  
slim-line  
SATA  
Optical  
and/or  
TBU Only  
(no HDD)  
Yes, 2  
ports for  
Optical  
and/or  
TBU  
On Planar  
via chipset  
n/a  
n/a  
n/a  
Yes  
x1 int  
n/a  
n/a  
n/a  
n/a  
Internal or  
External  
SCSI  
SCSI  
int  
SCSI  
ext  
LSI 2032  
Adapter  
PCIe  
slot  
Tape/  
Yes, Max 2  
x8  
Legacy  
External  
storage  
Note: A maximum of 2 external storage controllers (Dell PERC or SAS cards) are allowed in the system in  
addition to the integrated storage controller.  
40  
Dell™ PowerEdge™ R710 Technical Guidebook  
e. leD indicators  
Each disk drive carrier has two LED indicators visible from the front of the system. One is a green LED  
for disk activity and the other is a bicolor (green/amber) LED for status information. The activity LED is  
driven by the disk drive during normal operation. The bicolor LED is controlled by the SEP device on the  
backplane. Both LEDs are used to indicate certain conditions under direction of a storage controller.  
f. Optical Drives  
Optical drives are optional in all of the PowerEdge R710 systems and connect to the planar via the SATA  
interface. The following internal slim-line drives are available on the PowerEdge R710: DVD-ROM and  
DVD+RW. PATA (IDE) optical drives are not supported.  
If an optical drive is not ordered with the system, a blank is installed in its place.  
G. tape Drives  
Internal tape drives are optional in systems with the 4x3.5" or 8x2.5" backplanes. Internal SATA tape  
drives connect directly to the SATA connector on the planar. Internal SCSI tape drives connect through  
the LSI 2032 PCI Express SCSI adapter card.  
taPe DRives  
Internal (RD1000 Half-Height SATA)  
Internal Tape  
DAT72 Half –Height SCSI  
Internal Tape  
One 3.5" Half-Height Tape Drive Bay  
Drive Bays  
External (RD1000 USB)  
LTO-2L (Legacy, SCSI)  
LTO-3-060 (SCSI)  
LTO-3 (Legacy, SCSI)  
External TBU  
LTO-4-120 (Half-Height SAS)  
LTO-4-120 (Full-Height SAS)  
2U external TBU (PV114T)  
DAT72 Half–Height SCSI  
4U SAS, SCSI, iSCSI, and FC  
2U SAS, SCSI, iSCSI, and FC  
External  
TBU/Automation  
ML6000 Family SAS, SCSI, and FC  
2U external TBU (PV124T ) Legacy SCSI  
41  
Dell™ PowerEdge™ R710 Technical Guidebook  
chassis cOnfiG taPe backuP unit (inteRnal)  
backplane type  
config  
tbu controller  
tbu cable  
3.5" x 6"  
No TBU  
No TBU  
N/A  
N/A  
N/A  
N/A  
Internal for 3.5 Bay (RD 1000 Half-Height  
SATA)  
Connects to MB  
XR724  
3.5" x 4"  
DAT72 for 3.5 Bay (Half-Height SCSI)  
No TBU  
LSI 2032 (SCSI) HBA  
N/A  
DR017  
N/A  
Internal for 3.5 Bay (RD 1000  
Half-Height SATA)  
Connects to MB  
RN694  
CJ176  
2.5" x 8  
DAT72 for 3.5 Bay (Half-Height SCSI)  
LSI 2032 (SCSI) HBA  
sectiOn 13. viDeO  
a. Overview / Description  
The PowerEdge R710 Integrated Dell Remote Access Controller 6 (iDRAC6) incorporates an integrated  
video subsystem, connected to the 32-bit PCI interface of the ICH9. This logic is based on the Matrox  
G200. The device only supports 2D graphics. The video device outputs are multiplexed between the  
front and rear video ports. If a monitor is connected to the front video connector, it will take precedence  
over the rear connection, thereby removing the display from the rear connection. The integrated video  
core shares its video memory with the iDRAC6’s 128MB DDR2 application space memory. This memory  
is also used for the KVM buffer.  
The PowerEdge R710 system supports the following 2D graphics video modes:  
ResOlutiOn  
RefResh Rate (hz)  
cOlOR DePth (bit)  
640 x 480  
800 x 600  
1024 x 768  
1152 x 864  
1280 1024  
1280 1024  
60, 72, 75, and 85  
56, 60, 72, 75, and 85  
60, 72, 75, and 85  
75  
8, 16, and 32  
8, 16, and 32  
8, 16, and 32  
8, 16, and 32  
8 and 16  
60, 75, and 85  
60  
32  
42  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 14. auDiO  
a. Overview / Description  
No speakers supported  
sectiOn 15. Rack infORmatiOn  
a. Overview / Description  
Rack installation components such as rails are provided with the PowerEdge R710 Rack Kit. The rack  
installation components are as follows: Sliding Rack mount with latest generation Cable Management  
Arm (CMA). When the system is installed in a rack, please observe the following guidelines:  
Nothing should be located within 12" of the front of the unit that would restrict the airflow into the system.  
Nothing should be mounted or placed behind the chassis that would restrict airflow from exiting the  
system. Only Dell approved CMAs can be placed behind the chassis. All other objects should be located  
at least 24" away from the rear of the chassis.  
When two systems are placed back to back, the separation between the units should be at least 24" if  
the exit airflow is equivalent for the two chassis. This allows the exit air to escape without creating an  
extreme back pressure at the rear of one of the chassis.  
b. cable management arm (cma)  
cable tyPe  
numbeR Of cables  
Mouse – USB  
Keyboard – USB  
Video – VGA  
Power Cords  
LOMs – Ethernet  
PCI NICs  
1
1
1
2
1
1
Total  
8
Notes: • CMA supports for the maximum number of cables supported by system  
• The numbers in this matrix represent the number and types of external cables required to be  
supported by the CMA solution.  
• This matrix is built on the practical worst case configuration in each platform based on prior  
and projected take rates. Note that other combinations of adapters and associated cables exist,  
but are assumed to fall within these guidelines from the standpoint of bend radius and  
flexibility, cable bundling, cable volume, etc.  
• PCI NIC cables are assumed to be Ethernet.  
• KVM cable dongle may be used for mouse/keyboard/video.  
43  
Dell™ PowerEdge™ R710 Technical Guidebook  
c. Rails  
Support for tool-less installation in CEA-310-E compliant square hole 4-post racks including:  
Support for Dell 2410 24U Rack  
Support for Dell 4210 Rack  
Support for HP/Compaq 10xxx series  
Support for tooled or tool-less installation in CEA-310-E compliant round hole 4-post racks  
(tool-less preferred)  
Support for flush and center mount installation in CEA-310-E compliant 2-post racks (1U & 2U only)  
The R710 rail supports the following racks:  
Support for Dell 4210 & 2410 racks  
Support for Dell 4200 & 2400 racks without CMA  
Support for HP/Compaq 10XXX series racks  
Support for HP/Compaq 9XXX & 7XXX series racks without CMA  
44  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 16. OPeRatinG systems  
a. Overview / Description  
The PowerEdge R710 supports Windows®, Linux®, and Solaris™ Operating Systems.  
Windows® Support:  
x86  
factORy  
installatiOn  
lOGO  
ceRtificatiOn  
test/  
OR  
installatiOn  
scheDule  
suPPORt  
valiDate  
x64  
Windows® Small Business Server 2008 and Essential Business Server 2008  
Windows  
Standard/  
Premium  
Hardware  
x64  
Yes  
Shipping  
Shipping  
Yes  
Yes  
Yes  
Quality Labs -  
Windows 2008  
Windows Server® 2008 (x64 includes Hyper-V™)  
Standard  
Windows  
Hardware  
x64  
Yes  
Yes  
Enterprise  
Datacenter  
Quality Labs -  
Windows 2008  
Windows Server® 2008  
Windows  
Hardware  
Quality Labs -  
Windows 2008  
Standard  
x86  
Yes  
Yes  
Shipping  
Shipping  
Yes  
Yes  
Yes  
Yes  
Enterprise  
Windows® Web Server 2008  
Windows  
Hardware  
Quality Labs -  
Windows 2008  
x86  
and  
x64  
Web  
Windows Server® 2008, SP2 (x64 includes Hyper-V™)  
Standard  
Windows  
Available in  
August -  
October  
2009  
Hardware  
x64  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Enterprise  
Datacenter  
Quality Labs -  
Windows 2008  
Windows Server® 2008, SP2  
Windows  
Hardware  
Quality Labs -  
Windows 2008  
Available in  
August -  
October  
2009  
Standard  
x86  
Yes  
Enterprise  
Windows® Web Server 2008, SP2  
Windows  
Hardware  
Quality Labs -  
Windows 2008  
Available in  
August -  
October  
2009  
x86  
and  
x64  
Web  
Yes  
45  
Dell™ PowerEdge™ R710 Technical Guidebook  
x86  
factORy  
installatiOn  
lOGO  
ceRtificatiOn  
test/  
OR  
installatiOn  
scheDule  
suPPORt  
valiDate  
x64  
Windows Server® 2008, R2, (x64 includes Hyper-V™)  
Windows  
Available in  
November  
2009 -  
January  
2010  
Standard  
Enterprise  
Datacenter  
Hardware  
Quality Labs -  
Windows 2008  
Release 2  
x64  
Yes  
Yes  
Yes  
Linux support:  
Red Hat® Enterprise Linux 4.7  
x86  
and  
x64  
Available in  
June 2009  
Available in  
June 2009  
ES/AS  
N/A  
N/A  
N/A  
Yes  
Yes  
Yes  
Yes  
Red Hat Enterprise Linux 5.2  
x86  
and  
x64  
Standard/AP  
Yes  
Shipping  
Red Hat Enterprise Linux 5.3  
x86  
and  
x64  
Available in  
June 2009  
Available in  
June 2009  
Standard/AP  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Novell® SUSE® Linux Enterprise Server 10 SP2  
x64 Enterprise Yes  
N/A  
N/A  
Shipping  
Novell SUSE Linux Enterprise Server 11  
Available in  
June 2009  
Available in  
June 2009  
x64  
Enterprise  
Solaris™ 10 05/09  
x64 Enterprise  
Available in  
June 2009  
Drop in the box  
N/A  
Yes  
Yes  
46  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 17. viRtualizatiOn  
a. Overview / Description  
Supported embedded hypervisors:  
• Microsoft® Windows Server® 2008 Hyper-V  
• VMware® ESXi Version 4.0 and 3.5 update 4  
• Citrix® XenServer 5.0 with Hotfix 1 or later  
sectiOn 18. systems manaGement  
a. Overview / Description  
Dell is focused on delivering open, flexible, and integrated solutions the help our customers reduce the  
complexity of managing disparate IT assets. We build comprehensive IT management solutions.  
Combining Dell PowerEdge Servers with a wide selection of Dell-developed management solutions, we  
provide customers choice and flexibility – so you can simplify and save in environments of any size.  
To help you meet your server performance demands, Dell offers Dell OpenManage™ systems  
management solutions for:  
• Deployment of one or many servers from a single console  
• Monitoring of server and storage health and maintenance  
• Update of system, operating system, and application software  
We offer IT management solutions for organizations of all sizes – priced right, sized right, and  
supported right.  
b. server management  
A Dell Systems Management and Documentation DVD and a Dell Management Console DVD are included  
with the product. ISO images are also available. The following sections briefly describe the content.  
Dell Systems Build and Update Utility: Dell Systems Build and Update Utility assists in OS install and  
pre-OS hardware configuration and updates.  
OpenManage Server Administrator: The OpenManage Server Administrator (OMSA) tool provides a  
comprehensive, one-to-one systems management solution, designed for system administrators to  
manage systems locally and remotely on a network. OMSA allows system administrators to focus on  
managing their entire network by providing comprehensive one-to-one systems management.  
Management Console: Our legacy IT Assistant console is also included, as well as tools to allow access  
to our remote management products. These tools include: Remote Access Service, for iDRAC, and the  
BMC Management Utility.  
Active Directory Snap-in Utility: The Active Directory Snap-in Utility provides an extension snap-in to  
the Microsoft Active Directory. This allows you to manage Dell specific Active Directory objects. The  
Dell-specific schema class definitions and their installation are also included on the DVD.  
Dell Systems Service Diagnostics Tools: Dell Systems Service and Diagnostics tools deliver the latest  
Dell optimized drivers, utilities, and operating system-based diagnostics that you can use to update  
your system.  
eDocs: The section includes Acrobat files for PowerEdge systems, storage peripheral and  
OpenManage software.  
47  
Dell™ PowerEdge™ R710 Technical Guidebook  
Dell Management Console DVD: The Dell Management Console is a Web-based systems management  
software that enables you to discover and inventory devices on your network. It also provides advanced  
functions, such as health and performance monitoring of networked devices and patch management  
capabilities for Dell systems.  
Server Update Utility: In addition to the Systems Management Tools and Documentation and Dell  
Management Console DVDs, customers have the option to obtain Server Update Utility DVD. This  
DVD has an inventory tool for managing updates to firmware, BIOS and drivers for either Linux or  
Windows varieties.  
c. embedded server management  
The PowerEdge R710 implements circuitry for the next generation of Embedded Server Management. It  
is Intelligent Platform Management Interface (IPMI) v2.0 compliant. The iDRAC6 (Integrated Dell Remote  
Access Controller) is responsible for acting as an interface between the host system and its management  
software and the periphery devices. These periphery devices consist of the PSUs, the storage backplane,  
integrated SAS HBA or PERC 6/i and control panel with semi-intelligent display.  
The iDRAC6 provides features for managing the server remotely or in data center lights-out  
environments.  
Advanced iDRAC features require the installation of the iDRAC6 Enterprise card.  
I. Unmanaged Persistent Storage  
The unmanaged persistent storage consists of two ports:  
• one located on the control panel board  
• one located on the Internal SD Module  
The port on the control panel is for an optional USB key and is located inside the chassis. Some of the  
possible applications of the USB key are:  
• User custom boot and pre-boot OS for ease of deployment or diskless environments  
• USB license keys for software applications like eToken™ or Sentinel Hardware Keys  
Storage of custom logs or scratch pad for portable user-defined information (not hot-pluggable)  
The Internal SD Module is dedicated for an SD Flash Card with embedded Hypervisor for virtualization.  
The SD Flash Card contains a bootable OS image for virtualized platforms.  
II. Lifecycle Controller/Unified Server Configurator  
Embedded management is comprised of several pieces which are very interdependent.  
• Lifecycle Controller  
• Unified Server Configurator  
• iDRAC6  
• vFLASH  
Lifecycle controller is the hardware component that powers the embedded management features. It is  
integrated and tamperproof storage for system-management tools and enablement utilities (firmware,  
drivers, etc.). It is flash partitioned to support multiple, future use cases.  
Dell Unified Server Configurator is a 1:1 user interface exposing utilities from Lifecycle Controller. Customers  
will use this interface to configure hardware, update server, run diagnostics, or deploy the operating  
system. This utility resides on Lifecycle Controller. To access the Unified Server Configurator, press <F10>  
key within 10 seconds of the Dell logo display during the system boot process. Current functionality  
enabled by the Unified Server Configurator includes:  
48  
Dell™ PowerEdge™ R710 Technical Guidebook  
featuRe  
DescRiPtiOn  
Drivers and the installation utility are embedded on system, so no need to  
scour DELL.COM  
Faster O/S  
Installation  
Integration with Dell support automatically directed to latest versions  
of the Unified Server Configurator iDRAC, RAID, BIOS, NIC, and  
Power Supply  
Faster System Updates  
Update Rollback  
Description: Ability to recover to previous “known good state” for all  
updatable components  
More Comprehensive  
Diagnostics  
Diagnostic utilities are embedded on system  
Detects RAID controller and allows user to configure virtual disk  
and choose virtual disk as boot device, eliminating the need to  
launch a separate utility and also provides configuration for iDRAC,  
BIOS, and NIC/LOM.  
Simplified Hardware  
Configuration  
III. iDRAC6 Express  
The iDRAC6 Express is the first tier of iDRAC6 upgrades. In addition to upgrading the system with a  
Lifecycle Controller, the iDRAC6 Express offers the following key features:  
• Graphical web interface  
• Standard-based interfaces  
• Server Sensor monitoring and fault alerting  
• Secure operation of remote access functions including authentication, authorization,  
and encryption  
• Power control and management with the ability to limit server power consumption and  
remotely control server power states  
• Advanced troubleshooting capabilities  
For more information on iDRAC6 Express features see the table below.  
IV. iDRAC6 Enterprise  
The optional iDRAC6 Enterprise card provides access to advanced iDRAC6 features. The iDRAC6  
Enterprise connects directly to the PowerEdge R710 planar and is mounted parallel to the planar  
with stand-offs.  
Key features for the iDRAC6 Enterprise include:  
• Scripting capability with Dell’s Racadm command-line  
• Remote video, keyboard, and mouse control with Virtual Console  
• Remote media access with Virtual Media  
• Dedicated network interface  
Additionally, the iDRAC6 Enterprise can be upgraded by adding the vFlash Media card. This is a 1GB  
Dell branded SD card that enabled a persistent 256MB virtual flash partition. In the future, vFlash will be  
expanded to include additional features.  
49  
Dell™ PowerEdge™ R710 Technical Guidebook  
A more detailed feature list for iDRAC6 Enterprise and vFlash is included in the table below.  
iDRac6  
iDRac6  
vflash  
meDia  
featuRe  
bmc  
exPRess  
enteRPRise  
Interface and Standards Support  
IPMI 2.0  
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Web-based GUI  
SNMP  
WSMAN  
SMASH-CLP  
Racadm command-line  
Conductivity  
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Shared/Failover Network Modes  
IPv4  
VLAN tagging  
IPv6  
Dynamic DNS  
Dedicated NIC  
Security & Authentication  
Role-based Authority  
Local Users  
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Active Directory  
SSL Encryption  
Remote Management & Remediation  
Remote Firmware Update  
Server power control  
Serial-over-LAN (with proxy)  
Serial-over-LAN (no proxy)  
Power capping  
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Last crash screen capture  
Boot capture  
Serial-over-LAN  
Virtual media  
Virtual console  
50  
Dell™ PowerEdge™ R710 Technical Guidebook  
iDRac6  
iDRac6  
vflash  
meDia  
featuRe  
bmc  
exPRess  
enteRPRise  
4
4
4
Virtual console sharing  
Virtual flash  
Monitoring  
4
4
4
4
4
4
4
4
4
4
4
4
4
Sensor Monitoring and Alerting  
Real-time Power Monitoring  
Real-time Power Graphing  
Historical Power Counters  
Logging Features  
System Event Log  
RAC Log  
4
4
4
4
4
4
4
4
4
4
Trace Log  
51  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 19. PeRiPheRals  
a. usb peripherals  
The PowerEdge R710 supports the following USB devices:  
• DVD (bootable; requires two USB ports)  
• USB Key (bootable)  
• Keyboard (only one USB keyboard is supported)  
• Mouse (only one USB mouse is supported)  
b. external storage  
exteRnal stORaGe  
EMC's AX Arrays (SCSI, FC, and iSCSI)  
SAN Support  
EMC's CX Arrays (SCSI, FC, and iSCSI)  
EqualLogic's PS5XXX Arrays (iSCSI)  
OMSS X.X for MD1000  
OMSS X.X for MD1020  
SAS Management  
SW for xBOD  
X.X for MD3000  
for MD3000i  
Attachment to PV NX1950 including iSCSI and clustering support  
Attachment to Win Storage Server on PE  
Attachment to EMC NS500G (S&P)  
MD1000 JBOD  
PV NAS  
PV DAS  
MD3000 RBOD  
MD1120 2.5 SAS/SATA JBOD  
MD1100 3.5 SAS/SATA JBOD  
MD3000i iSCSI RAID array  
PS5000 family  
PV SAN  
EqualLogic™  
SAS xBOD SW  
PS5500 family  
OpenManage Storage Manager  
52  
Dell™ PowerEdge™ R710 Technical Guidebook  
sectiOn 20. DOcumentatiOn  
a. Overview, Description, and list  
PowerEdge R710 and other 11G systems use the new enterprise documentation set. The following is a  
summary of some of the documents slated for the PowerEdge R710 product. For the complete list of  
documents, including language requirements and delivery scheduling, refer to the Documentation Matrix  
and the Documentation Milestones in the InfoDev Functional Publications Plan.  
• Getting Started Guide: This guide provides initial setup steps, a list of key system features, and  
technical specifications. This document is required for certain worldwide regulatory submittals.  
This guide is printed and shipped with the system, and is also available in PDF format on the  
Dell support site.  
• Hardware Owner’s Manual: This document provides troubleshooting and remove/replace  
procedures, as well as information on the System Setup program, system messages, codes,  
and indicators. This document is provided to customers in HTML and PDF format at the Dell  
support site.  
• System Information Label: The system information label documents the system board layout  
and system jumper settings and is located on the system cover. Text is minimized due to space  
limitations and translation considerations. The label size is standardized across platforms.  
• Information Update: This is a PDF document that provides information on late changes and  
issues having significant customer impact which were discovered after document signoff.  
• General System Information Placemat: This is a paper document that is provided with every  
system. The document provides general information about the system, including software  
license agreement information and the location of the service tag.  
• Rack Placemat: This is a paper document that is provided with the rack kits. The document  
provides an overview of procedures for setting up the rack.  
sectiOn 21. PackaGinG OPtiOns  
PackaGinG  
PROviDe PackaGinG tO suPPORt system  
Will not bag the server in outbound pack  
Multi-pack rails targeted to go in a box within the  
multi-pack but investigation underway for a separate  
box for ease of customer staging  
Accessory tray needs a cover and icon showing contents  
Doc Box – separate box within the main box containing  
import documentation and software (OS, OM, etc.)  
Packaging should  
incorporate keyboard,  
mouse, bezel, Doc,  
CDs, rails  
53  
Dell™ PowerEdge™ R710 Technical Guidebook  
appendix  
R710 Volatility Chart.  
nOn-  
vOlatile  
Ram  
vOlatile RefeRence  
tyPe [e.g., flash PROm,  
EEPROM]:  
qty size  
Ram  
DesiGnatOR  
PlanaR, POWeReDGe R710  
4MB  
Flash EEPROM (SPI interface)  
System BIOS SPI Flash  
LOM Configuration Data  
iDRAC6 Controller ROM  
iDRAC6 Controller RAM  
System CPLD  
Y
Y
Y
U_SPI_BIOS  
U15, U16  
U_IBMC  
1
2
1
512KB  
FLASH (NOR)  
ROM  
4KB  
8KB  
RAM  
Y
U_IBMC  
1
1200 Macro cells  
Internal Flash EEPROM  
RAM  
Y
Y
U_CPLD  
U_CPLD  
U_EMMC  
1
1KB  
1GB  
System CPLD  
Y
Y
1
NAND FLASH  
iDRAC6 Express Internal Flash  
1
J_CPU(2:1)_  
CH(2:0)_  
DIMM(3:1)  
up to 18 DIMMs  
*16GB  
RAM  
System RAM  
18  
TPM ID EEPROM  
(Plug in module only)  
256B  
256B  
128MB  
4KB  
EEPROM  
EEPROM  
DDR2 RAM  
EEPROM  
Y
Y
U_SEEPROM  
U7261  
1
1
1
1
TPM Binding EEPROM  
(on China planar only)  
U_IBMC_  
MEM  
iDRAC6 SDRAM  
iDRAC6 FRU  
Y
U_IBMC_  
FRU  
Y
2MB  
FLASH (NOR)  
EEPROM  
iDRAC6 Boot Block Flash  
Trusted Platform Module  
chiPset  
Y
Y
U_IBMC_SPI  
U_TPM  
1
1
128 bytes  
N
256KB  
32KB  
Battery backed RAM  
CMOS  
Y
U_ICH9  
U_SEP  
1
1
2.5" backPlane OR 3.5" backPlane  
Embedded Microcontroller  
Flash  
Storage Controller Processor  
cOntROl Panel  
Y
J_USBKEY  
(connector)  
License key hard set ROM or  
user choice  
User selectable  
Internal USB  
Y
Y
1
1
J_SDCARD  
(Connector)  
User selectable -  
1GB shipped  
Secure Digital NAND Flash  
Internal SD Module  
POWeR suPPly  
Maximum  
supported = 2MB  
per PSU  
Varies by  
part number  
Up  
to 2  
Embedded microcontroller  
flash  
PSU Microcontroller  
Y
PeRc 6/i inteGRateD  
PERC NVSRAM Config Data  
32KB  
Non-volatile SRAM  
FLASH (NOR)  
RAM  
Y
Y
U23  
1
1
1
1
1
1
PERC Firmware  
4MB  
U24  
PERC Cache RAM  
FRU  
256MB  
256MB  
1KB  
Y
U58-61  
U40  
EEPROM  
Y
Y
Y
IBUTTON Key EEPROM  
CPLD  
EEPROM  
U21  
72 macrocells  
Internal Flash EEPROM  
U_CPLD  
SAS 6/iR Integrated  
Controller Configuration Data  
FRU  
4MB  
FLASH (NOR)  
EEPROM  
Y
Y
Y
U3  
U4  
U1  
1
1
1
256KB  
32KB  
Integrated Mirroring NVSRAM  
iDRAC6 Enterprise  
Non-volatile SRAM  
J_SD  
(connector)  
1GB @ RTS,  
Larger later  
VFlash  
Secure Digital NAND Flash  
Y
1
54  
Dell™ PowerEdge™ R710 Technical Guidebook  
R710 Volatility Chart Continued.  
can useR PROGRams OR OPeRatinG  
system WRite Data tO it DuRinG  
nORmal OPeRatiOn?  
PuRPOse? [e.g., bOOt cODe]  
PlanaR, POWeReDGe R710  
Boot Code, System Configuration Information, EUFI  
environment  
System BIOS SPI Flash  
No  
LOM Configuration Data  
iDRAC6 Controller ROM  
iDRAC6 Controller RAM  
System CPLD  
No  
No  
No  
No  
No  
LAN on motherboard configuration and firmware  
not utilized  
iDRAC internal RAM  
System-specific hardware logic  
not utilized  
System CPLD  
iDRAC Operating System plus Managed System Services  
Repository (i.e., Unified Server Configurator, OS drivers,  
diagnostics, rollback versions of various programmables)  
No for iDRAC Operating System. Yes for  
Managed System Services Repository  
iDRAC6 Express Internal Flash  
System RAM  
Yes  
No  
System OS RAM  
TPM ID EEPROM  
(Plug in module only)  
BIOS Identification of TPM module  
TPM Binding EEPROM  
(on China planar only)  
No  
BIOS binding of plug in module to a particulare planar  
iDRAC6 SDRAM  
iDRAC6 FRU  
No  
No  
BMC OS + VGA frame buffer  
Motherboard electronic product identifier  
iDRAC boot loader and configuration (i.e., MAC address),  
life cycle log, and system event log  
iDRAC6 Boot Block Flash  
No  
Trusted Platform Module  
chiPset  
yes  
Storage of encryption keys  
CMOS  
No  
BIOS settings  
2.5" backPlane OR 3.5" backPlane  
Storage Controller Processor  
No  
Backplane firmware (HDD status, etc.)  
cOntROl Panel  
Normal usage is read only software license key, but not  
limited  
Internal USB  
Yes as allowed by OS  
Yes as allowed by OS  
Normal usage is embedded hypervisor OS but not  
limited  
Internal SD Module  
POWeR suPPly  
Power supply operation, power telemetry data, and fault  
behaviors  
PSU Microcontroller  
No  
PeRc 6/i inteGRateD  
PERC NVSRAM Config Data  
PERC Firmware  
No  
Stores configuration data of HDDs  
Storage Controller Firmware  
Storage RAID controller cache  
No  
PERC Cache RAM  
No - not directly.  
Card product identification for system inventory  
purposes  
FRU  
No  
IBUTTON Key EEPROM  
CPLD  
No  
No  
Feature enablement encyrpted key  
HW control logic (i.e., power sequencing)  
SAS 6/iR Integrated  
Controller Configuration Data  
No  
No  
No  
Stores configuration data of HDDs  
Card product identification for system inventory  
purposes  
FRU  
Integrated Mirroring NVSRAM  
iDRAC6 Enterprise  
Stores configuration data of HDDs  
Yes - When enabled, installed, and the media  
does not have the write protect switch applied  
VFlash  
Storage of logs, user images like files, drivers, OS's, etc.  
55  
Dell™ PowerEdge™ R710 Technical Guidebook  
R710 Volatility Chart Continued.  
hOW is Data inPut tO this memORy?  
PlanaR, POWeReDGe R710  
Loading flash memory requires a vendor-provided firmware file and loader program that is executed by booting  
up the system from a floppy or OS-based executable containing the firmware file and the loader. System  
loaded with arbitrary data in firmware memory would not operate. Future firmware releases may add support  
for recovery of a bad/corrupted BIOS ROM image via the iDRAC (administrator privilege plus specific firmware,  
binary, and commands)  
System BIOS SPI Flash  
Loading flash memory requires a vendor-provided firmware file and loader program that is executed by booting  
up the system from a floppy or OS-based executable containing the firmware file and the loader. LOMs loaded  
with arbitrary data in firmware memory would not operate.  
LOM Configuration Data  
iDRAC6 Controller ROM  
iDRAC6 Controller RAM  
N/A  
iDRAC embedded system  
Loading flash memory requires a vendor-provided firmware file and loader program that is executed by booting  
up the system from a floppy or OS-based executable (currently only DRMK utility support) containing the  
firmware file and the loader. System loaded with arbitrary data in CPLD memory would not operate.  
System CPLD  
System CPLD  
Not utilized  
iDRAC OS: Loading flash memory requires a vendor-provided firmware file and loader program that is executed  
by booting up the system from a floppy or OS-based executable containing the firmware file and the loader.  
System loaded without a good iDRAC firmware image yields a non-functional iDRAC. Managed Services  
Repository: Various partitions are loaded via vendor-provided firmware file and loader program just like iDRAC  
OS.  
iDRAC6 Express Internal  
Flash  
System RAM  
System OS  
TPM ID EEPROM  
(Plug in module only)  
Factory load only.  
TPM Binding EEPROM  
(on China planar only)  
BIOS only  
iDRAC6 SDRAM  
iDRAC6 FRU  
Embedded iDRAC OS for 108MB and 8MB for VGA frame buffer  
Factory and iDRAC embedded OS  
Loading flash memory requires a vendor-provided firmware file and loader program that is executed by booting  
up the system from a floppy or OS-based executable or out-of-band firmware updates across the management  
network. Bad contents yield the iDRAC inoperable and unrecoverable in the customer environment. Note the  
life cycle log is automatically updated by the iDRAC as various system component FW, HW, and SW verions are  
changed.  
iDRAC6 Boot Block  
Flash  
Trusted Platform Module  
chiPset  
Using TPM-enabled operating systems  
CMOS  
BIOS control only via input such as BIOS F2 menu user configuration settings (such as boot order)  
2.5" backPlane OR 3.5" backPlane  
Loading flash memory requires a vendor-provided firmware file and loader program that is executed by booting  
up the system from a floppy or OS-based executable (DRMK, USC, OS DUPs utility support) containing the firm-  
ware file and the loader. Backplane loaded with bad firmware will not provide backplane and HDD status.  
Storage Controller Pro-  
cessor  
cOntROl Panel  
Internal USB  
Either read-only license key or OS control copies  
Internal SD Module  
Factory load, OS run time usage, and OS updates and configuration changes.  
POWeR suPPly  
Loading flash memory requires a vendor-provided firmware file and loader program that is executed by booting  
up the system from a floppy or OS-based executable (Unified Server Configurator) containing the firmware file  
and the loader. PSUs loaded with bad firmware will not provide PSU functional behavior and result in PSU system  
faults.  
PSU Microcontroller  
PeRc 6/i inteGRateD  
PERC NVSRAM Config  
Data  
Embedded storage firmware controls this data  
Loading flash memory requires a vendor-provided firmware file and loader program that is executed by booting  
up the system from a floppy or OS-based executable (DUPs, Unified Server Configurator) containing the firmware  
file and the loader. Storage adapters loaded with bad firmware will not provide storage controller behavior.  
PERC Firmware  
PERC Cache RAM  
FRU  
Embedded storage firmware controls the use of storage cache data.  
Factory only. Not customer updatable.  
IBUTTON Key EEPROM  
CPLD  
Factory only. Not customer updatable.  
Factory only. Not customer updatable.  
SAS 6/iR Integrated  
56  
Dell™ PowerEdge™ R710 Technical Guidebook  
R710 Volatility Chart Continued.  
hOW is Data inPut tO this memORy?  
PlanaR, POWeReDGe R710  
Loading flash memory requires a vendor-provided firmware file and loader program that is executed by booting  
up the system from a floppy or OS-based executable (DUPs, Unified Server Configurator) containing the firmware  
file and the loader. Storage adapters loaded with bad firmware will not provide storage controller behavior.  
Controller Configuration  
Data  
FRU  
Factory only. Not customer updatable.  
Integrated Mirroring  
NVSRAM  
Embedded storage firmware controls this data  
iDRAC6 Enterprise  
Preloaded media before installation, or remote out-of-band upload of user data (i.e., ISO images, files) or local  
server read/write capability to use like a hard disk  
VFlash  
hOW is this memORy WRite PROtecteD?  
PlanaR, POWeReDGe R710  
hOW is the memORy cleaReD?  
Not possible with any utilities or applications and  
system is not functional if corrupted/removed.  
System BIOS SPI Flash  
Software write protected  
Not explicitly protected but special applications  
are needed to communicate through the LOMs to  
reprogram this ROM.  
LOM Configuration Data  
Not user clearable  
iDRAC6 Controller ROM  
iDRAC6 Controller RAM  
Protected permanently by hardware  
n/a  
Not clearable  
iDRAC reset  
Not possible with any utilities or applications and  
system is not functional if corrupted/removed.  
System CPLD  
System CPLD  
Requires special system-specific utility  
It's not accessible  
Not clearable  
Writes are proxied through a temporary iDRAC  
scratchpad RAM and not directly made from an OS or  
OS application.  
iDRAC6 Express Internal  
Flash  
Not user clearable  
System RAM  
OS control  
Reboot or power down system  
Not - read only  
TPM ID EEPROM  
(Plug in module only)  
HW read only  
TPM Binding EEPROM  
(on China planar only)  
Locked by BIOS from physical access by anyone after  
boot  
N/A - BIOS control only  
AC cycle for BMC OS and reset / power off server for  
VGA frame buffer  
iDRAC6 SDRAM  
iDRAC6 FRU  
n/a  
Writes controlled by iDRAC embedded OS  
EPPID is not clearable  
Not possible with any utilities or applications and  
iDRAC does not function as expected if corrupted/  
removed. Lifecycle log is clearable only in a factory  
environment. SEL is user clearable.  
iDRAC6 Boot Block  
Flash  
iDRAC embedded OS control of the write protection.  
Trusted Platform Module SW write protected  
F2 setup option  
chiPset  
Planar NVRAM_CLR jumper or remove AC cord, remove  
cover, remove coin cell battery. Wait for 30 seconds,  
replace battery, cover, and then AC cord.  
CMOS  
N/A - BIOS only control  
F2 system setup option to restore defaults  
2.5" backPlane OR 3.5" backPlane  
Not possible with any utilities or applications and  
backplane does not function as expected if corrupted/  
removed.  
Storage Controller  
Processor  
Embedded firmware only writeable through controlled  
iDRAC methods  
cOntROl Panel  
Internal USB  
OS control  
OS control format  
OS control format  
Internal SD Module  
Only by SD card write-protect switch.  
POWeR suPPly  
Protected by the embedded microcontroller. Special  
keys are used by special vendor-provided utilities to  
unlock the ROM with various CRC checks during load.  
PSU Microcontroller  
N/A - not in-system clearable  
57  
Dell™ PowerEdge™ R710 Technical Guidebook  
R710 Volatility Chart Continued.  
hOW is this memORy WRite PROtecteD?  
hOW is the memORy cleaReD?  
PlanaR, POWeReDGe R710  
PeRc 6/i inteGRateD  
PERC NVSRAM Config  
Data  
Storage controller firmware accessed only  
N/A - not in-system clearable  
N/A - not in-system clearable  
PERC Firmware  
Write control access by storage controller firmware  
Storage controller firmware accessed only  
Storage controller firmware clearable only. Remove AC  
AND deplete or remove backup battery.  
PERC Cache RAM  
FRU  
Protected in that no iDRAC-embedded firmware writes  
to this device. Although very convoluted, theoretically,  
IPMI I2C Master write commands would flow through to  
overwrite this EEPROM  
N/A - not in-system clearable  
IBUTTON Key EEPROM  
CPLD  
SHA1 encryption included. Storage controller use only  
Only factory programmable  
N/A - not in-system clearable  
N/A - not in-system clearable  
SAS 6/iR Integrated  
Controller Configuration  
Data  
Write control access by storage controller firmware  
N/A - not in-system clearable  
N/A - not in-system clearable  
N/A - not in-system clearable  
Protected in that no iDRAC-embedded firmware writes  
to this device. Although very convoluted, theoretically,  
IPMI I2C Master write commands would flow through to  
overwrite this EEPROM  
FRU  
Integrated Mirroring  
NVSRAM  
Storage controller firmware accessed only  
iDRAC6 Enterprise  
iDRAC-based format or local OS format or delete or  
card removal and formatted on a client  
VFlash  
Media write protection switch or OS control  
58  

HP Hewlett Packard HP NVIDIA Tesla GPU Module C7S14A User Manual
Gigabyte GA EP45 UD3P User Manual
GE Profile PP989DN User Manual
Gaggenau KG 260 CA User Manual
Fisher Paykel Cooktop CG604D User Manual
Electrolux Thermaline WLXRABOOOO User Manual
Eizo FlexScan EV2303W User Manual
Eizo EIZO FlexScan T962 User Manual
Cypress CY7C1394BV18 User Manual
Black Box Computer Hardware VX HDMI IP VTX User Manual