DH
Document # PG07-007
Revised 07/03/13 Page 1/2
PLANNING
GUIDE
Distinctive™ 30 and 36” Wide
Wall Mount Range Hoods
All tolerances: ±1/16” (±1.6 mm), unless otherwise stated
warning
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
11 7/8 ”
(30.2 cm)
•
•
A
This appliance must be installed in accordance with the
accompanying installation instructions.
6”
(15.2 cm)
C
23 5/8”
(60.0 cm)
Model
Dimension (a)
DH3006S 29 7/8” (75.9 cm)
DH3606S 35 7/8” (91.1 cm)
ical
ccess
OvERALL DIMENsIONs
Specifications
Filters
2 mesh (baffle type optional, order kit # AHBF2)
Exhaust
8-inch
Total Connect
Load
120 Vac, 60 Hz, 2 Amp. Max. (10.0 Amp Max
Lights
Fan Rating*
Weight
2, 120 Vac, 75 W each halogen
340 CFM @ high setting, 275 CFM
DH3006S: 31 lbs. (14.1 kg) DH
* At zero inches static pressure. Tested with
straight duct. Consult your local building d
make up air requirements.
of
od
Standard 8” duct
C
connection
L
*Above cooking surface
Model
Dimension (C)
DH3006S 30” (76.2 cm)
DH3606S 36” (91.4 cm)
1 1/2”
(3.8 cm)
”
6 1/8
(15.6 cm)
CAbINET LAyOUT
Electrical access holes,
7/8” dia. (5.1 cm)
■
Maximum cooking appliance width: 30 inches for DH3006S, 36 inches
for DH3606S.
B
3”
(7.6 cm)
■
The exhaust duct and electrical wiring are connected from the top of
the hood.
Model
Dimension (B)
DH3006S
DH3606S
4 1/8” (10.5 cm)
6 9/16” (16.7 cm)
■
■
The hood must be centered horizontally over the cooktop/range.
Cabinet storage space located directly above the range should be
avoided.
TOP DIMENsIONs
All specifications subject to change without notice.
Phone: (800) 793-0093
|