CyberResearch GDR 15L TR User Manual

®
Displays  
GDR 15L Series  
15.1Flat-Panel TFT LCD Display  
GDR 15L: 15.1Rugged Desktop LCD Monitor  
GDR 15L-TR: GDR 15L with Resistive Touchscreen  
USER’S MANUAL  
VER. 1.1 • MAR 2005  
No part of this manual may be reproduced without permission  
®
CyberResearch , Inc.  
25 Business Park Dr., Branford, CT 06405 USA  
203-483-8815 (9am to 5pm EST) FAX: 203-483-9024  
CyberResearch® Displays  
GDR 15L Series  
©Copyright 2005  
All Rights Reserved.  
March 29, 2005  
The information in this document is subject to change without prior notice  
in order to improve reliability, design, and function and does not represent  
a commitment on the part of CyberResearch, Inc.  
In no event will CyberResearch, Inc. be liable for direct, indirect, special,  
incidental, or consequential damages arising out of the use of or inability  
to use the product or documentation, even if advised of the possibility of  
such damages.  
This document contains proprietary information protected by copyright.  
All rights are reserved. No part of this manual may be reproduced by any  
mechanical, electronic, or other means in any form without prior written  
permission of CyberResearch, Inc.  
Trademarks  
“CyberResearch,” and “GDR 15L Series,” are trademarks of  
CyberResearch, Inc. Other product names mentioned herein are used for  
identification purposes only and may be trademarks and/or registered  
trademarks of their respective companies.  
• NOTICE •  
CyberResearch, Inc. does not authorize any CyberResearch product for  
use in life support systems, medical equipment, and/or medical devices  
without the written approval of the President of CyberResearch, Inc. Life  
support devices and systems are devices or systems which are intended  
for surgical implantation into the body, or to support or sustain life and  
whose failure to perform can be reasonably expected to result in injury.  
Other medical equipment includes devices used for monitoring, data  
acquisition, modification, or notification purposes in relation to life  
support, life sustaining, or vital statistic recording. CyberResearch  
products are not designed with the components required, are not subject  
to the testing required, and are not submitted to the certification required  
to ensure a level of reliability appropriate for the treatment and diagnosis of  
humans.  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT USA  
iii  
P: (203) 483-8815; F: (203) 483-9024  
GDR 15L Series  
CyberResearch® Displays  
Intentionally Blank  
iv  
GDR 15L Series  
CyberResearch® Displays  
GDR 15L Series  
Table Of Contents  
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . .1  
2. Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . .2  
3. Connecting to a Computer . . . . . . . . . . . . . .3  
4. Image Control and Adjustment . . . . . . . . . .4  
5. Specifications . . . . . . . . . . . . . . . . . . . . . . .6  
6. Cleaning and Maintenance . . . . . . . . . . . . .9  
7. Service and Support . . . . . . . . . . . . . . . . . .9  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT USA  
vi  
P: (203) 483-8815; F: (203) 483-9024  
GDR 15L Series  
CyberResearch® Displays  
vii  
©Copyright 2005 CyberResearch, Inc.  
CyberResearch® Displays  
GDR 15L Series  
1.  
Introduction  
Thank you for purchasing the GDR 15L rugged TFT display.  
The GDR 15L range of products have been designed to provide the highest  
possible image quality, in a rugged housing that has specifically been  
manufactured to operate in environments that would normally be  
considered too harsh for normal computer equipment .  
What makes the GDR 15L different?  
The GDR 15L is a high quality, Ultra-Bright TFT LCD display with a resolution  
of 1024x768. Sleek yet solid, our GDR Series displays feature a two-piece  
cast aluminum shell with low-profile rubber buttons, designed to withstand  
the shock and vibration of industrial and vehicle use. The screen is crisp,  
flicker-free, and brilliant  
This well-thought out design is NEMA 12 dust and moisture resistant, with  
elastomer-sealed OSD geometry controls on the front panel for convenient  
screen image control. Locking power and signal connectors help prevent  
accidental disconnection.  
The GDR 15L has been rigorously tested to withstand severe shock and  
continual vibration and features a panel protected by 3mm toughened  
glass. Each display has a guaranteed 24-hour burn prior to shipping.  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT USA  
1
P: (203) 483-8815; F: (203) 483-9024  
GDR 15L Series  
CyberResearch® Displays  
2.  
Unpacking  
Along with the GDR 15L rugged TFT, each box should contain the following:  
1. Universal AC/DC Power Supply  
2. 2-meter VGA Connector Cable  
3. 3-pin IEC Power Lead  
4. 9-pin Serial Connector Cable  
5. Touch Drivers CD-ROM (GDR 15L-TR touchscreen model)  
6. User’s Manual  
*
If any of these items are not included, please contact CyberResearch.  
In the unlikely event of product failure, please retain the original packaging  
so that the units may be safely returned to us for service.  
Important Note: Do not use any other power supply, other than the one  
shipped with the unit. This may cause irreparable damage to either the  
panel or the electronics, and will in all cases invalidate the warranty.  
.
It is recommended that the display be used only in conjunction with  
the VGA cable supplied. Deterioration in picture quality may occur if  
a poorly shielded cable, or a longer cable is used in its place.  
2
©Copyright 2005 CyberResearch, Inc.  
CyberResearch® Displays  
GDR 15L Series  
3.  
Connection to the Computer  
GDR 15L Model  
Using the following simple instructions, the GDR 15L will be installed and  
configured within about five minutes.  
On the bottom of the GDR 15L, there are two ports—a 15-pin VGA port, and  
a power jack. One end of the VGA cable will already be connected to the  
VGA port when the unit is shipped.  
3.1 Turn off the computer.  
3.2 Attach the VGA cable to the video port on the PC and ensure that both  
thumbscrew connections are securely fastened.  
3.3 Insert the power jack on the power supply into the remaining circular  
port on the monitor, and connect the power supply to an outlet using  
the IEC power lead.  
3.4 Turn on the computer.  
3.5 Turn on the display.  
3.6 The display has not yet been configured, so the picture quality may  
not yet be optimized.  
GDR 15L-TR Touchscreen Model  
In addition to the above, the touchscreen model has an extra cable  
terminating in a 9-pin serial connector which connects to one of the PC’s  
serial ports.  
Power, VGA, & Touchscreen connectors on bottom of unit.  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT USA  
3
P: (203) 483-8815; F: (203) 483-9024  
GDR 15L Series  
CyberResearch® Displays  
4.  
Image Control and Adjustment  
There are two important steps in order to ensure that the best possible  
image quality is now obtained:  
4.1 Select the correct resolution and refresh rate.  
The GDR 15L is intended to run at a resolution of 1024x768 pixels.  
Although the unit can display in full screen mode at both 800x600  
and 640x480, we strongly recommend you now set the resolution  
to 1024x768.  
• Move the slider bar until the screen resolution is 1024x768.  
• Change the refresh rate to 60Hz  
• Set the number of colors to 16 million  
• Save settings before exiting.  
4.2 Run the On-Screen Auto Adjust Utility using the buttons on the front of  
the monitor:  
• Click the “Menu” Button once. The On-Screen Menu will now pop up and  
will already be highlighting the “Auto Adjust” option.  
• Click “Select.”  
• The display will now resize and reposition until an optimal image is  
achieved.  
• Wait five seconds and the On-Screen Controls will disappear.  
Important Note: The panel used in the GDR 15L can operate between  
a range of 60 and 75Hz. The best frequency will depend on the driver card  
in the PC. If at this stage there is any “noise” on the screen, we recommend  
the following:  
• Try increasing the refresh rate above 60Hz. Do not exceed 75Hz.  
• Fine-tune the Brightness, Contrast and Sharpness functions using  
the On-Screen Control.  
4.3 The GDR 15L is an extremely bright display, operating at 400 nits (400  
cd/m2). We strongly recommend that, unless the unit is used in very  
bright lighting conditions, the brightness be reduced to around 60 to  
70% using the On-Screen Control. This helps to eliminate any residual  
screen noise, and also will greatly prolong the backlight life of the  
panel.  
4
©Copyright 2005 CyberResearch, Inc.  
CyberResearch® Displays  
GDR 15L Series  
4.4 Changing the screen resolution:  
The GDR 15L can operate in full screen at either SVGA (800x600) or VGA  
(640x480) .The unit cannot operate at any resolution higher than  
1024x768.  
In order to step down resolution, simply select the “Display” icon in  
the Control Panel, chose “Settings,” and move the slider bar to  
the desired position.  
Note: When changing resolutions it may be necessary to run the On-Screen  
Auto Adjust utility in the new resolution in order to maximize image  
quality.  
Whenever the display is being used at 800x600 the image quality will never  
be as crisp and clear as when it is operating at its preferred resolution of  
1024x768. This is particularly noticeable when viewing text, especially  
small fonts. This is a due to the monitor “doubling” some pixels in order  
to fill the screen and is completely normal.  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT USA  
5
P: (203) 483-8815; F: (203) 483-9024  
GDR 15L Series  
CyberResearch® Displays  
Display  
Display Type  
LCD flat panel  
Video Input Types  
Screen Size (viewable area, diagonal)  
Standard analog VGA (15-pin)  
15.1"  
06" to 15"  
15" to 18"  
Display Filter Screen Size  
Display Brightness  
Display Filter Brightness  
Resolution, max.  
250 nits (High-Bright)  
High-bright (250 to 340 nits)  
1024 x 768 pixels  
Tempered glass  
Anti-reflective coating  
Screen Protection  
Maximum Number of Colors  
Maximum Color Depth in Bits  
Contrast Ratio  
16 million colors  
24-bit color  
300:1  
° Horizontal  
° Vertical  
160°  
110°  
Viewing Angle  
Rise  
Response Rate  
Decay  
60ms  
50ms  
Chassis  
Desktop / benchtop  
Swivel-arm mount  
Mounting Configuration  
Weighted desktop stand  
NEMA 12  
Protection Rating  
IP52 (most dust, falling water within 15 deg. of  
vertical)  
Display Filter Protection  
Front Panel Material  
Chassis Material  
Water-Resistant (NEMA 4/12, IP65)  
Die-cast metal  
Die-cast metal  
Custom Color Options  
Custom color available (min. qty: 100)  
Mounting  
VESA Mounting Hole Pattern  
75x75mm VESA mounting holes  
See optional mounting stands, brackets, and  
swivel arms below.  
Stand Features  
Touchscreen  
Touchscreen Type  
Resistive touchscreen  
RS-232 serial  
75%  
5-wire  
ELO  
Touchscreen Interface  
Light Transmittance of Touchscreen  
Touchscreen Quantity of Wires  
Touchscreen Manufacturer  
Touchscreen Resolution  
1024 x 1024 points  
Indicators, Switches, & Controls  
Brightness  
Contrast  
Sharpness  
On Screen Display (OSD) Control Functions  
Auto adjustment  
Power On/Off Switch  
Front Panel  
1 on/off switch  
Sealed OSD controls for menu navigation (4  
rubber keys)  
Controls  
OSD Controls  
Signal Connectors  
Video Input Connectors  
Touchscreen Connector  
HD15 (standard VGA) connector  
9-pin D-sub female  
Cables  
Video Cable Length (included)  
Pointing Device Cable Length (included)  
6 feet  
6ft (1.83m)  
A 6-foot male-male VGA cable is included with  
all models. Touchscreen models include a 6-foot  
DB-9 M-F touchscreen cable.  
Cabling Details  
6
GDR 15L Series  
CyberResearch® Displays  
GDR 15L Series  
Power Supply  
Power Supply Form Factor  
Nominal Input Voltage(s)  
Input Voltage Range(s)  
Input Frequency  
External (fully enclosed)  
110/220VAC  
100...240VAC  
50/60Hz  
Power Supply Input Connector  
Output Voltage(s)  
NEMA standard male PC cord socket  
+12VDC  
DC Input Power Info  
DC Input Voltage(s)  
+12VDC  
Cooling  
Cooling Summary  
Convection (runs in silence)  
Environmental Specifications  
Operating Temperature  
Storage Temperature  
32°F....122°F (0°C....50°C)  
-13°F....140°F (-25°C....60°C)  
5%....95%  
Relative Humidity, noncondensing  
18g half-sine for 6ms, 500 bumps per axis in  
each direction (total: 3000), operating.  
5 to 150Hz, 1.0g peak-to-peak for 2 hours per  
axis, operating.  
Shock Resistance  
Operating  
Operating  
Vibration  
Resistance  
Safety & Standards Compliance  
Safety/Approvals  
MTBF (average) -- Display Backlight  
Meets EMC Directive 89/336/EEC  
40000 hours  
Dimensions  
Width  
Height  
15.24" (387mm)  
10.98" (279mm)  
2.44" (62mm)  
Depth (including handles)  
Weight  
Weight  
9.9lbs (4.49kg )  
Under 16 lbs.  
Display Filter Weight  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT USA  
7
P: (203) 483-8815; F: (203) 483-9024  
GDR 15L Series  
CyberResearch® Displays  
154.5mm  
60mm  
94.5mm  
m m  
1 6  
3 0 9 m m  
8
©Copyright 2005 CyberResearch, Inc.  
CyberResearch® Displays  
GDR 15L Series  
6.  
Cleaning & Maintenance  
The viewing surface should be cleaned with a suitable general purpose  
anti-static wipe. Never use industrial cleaners or solvents, as there are  
special coatings on the viewing surface that could be damaged.  
7.  
Service and Support  
If you are not completely satisfied with your GDR 15L, simply call our  
toll-free hotline (1-800-341-2525) within 30 days of receiving the item.  
A friendly customer service technician will arrange for a full refund,  
replacement, exchange, or credit.  
If you have any questions about your GDR 15L, call our toll-free number in  
the USA (1-800-341-2525), call worldwide (203-483-8815), send a fax to  
(203-483-9024), or email our applications engineers at techsupport@cyber-  
research.com.  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT USA  
9
P: (203) 483-8815; F: (203) 483-9024  
GDR 15L Series  
CyberResearch® Displays  
10  
©Copyright 2005 CyberResearch, Inc.  
CyberResearch® Displays  
GDR 15L Series  
Product Service  
Diagnosis and Debug  
CyberResearch, Inc. maintains technical support lines staffed by experienced  
Applications Engineers and Technicians. There is no charge to call and we will  
return your call promptly if it is received while our lines are busy. Most problems  
encountered with data acquisition products can be solved over the phone. Signal  
connections and programming are the two most common sources of difficulty.  
CyberResearch support personnel can help you solve these problems, especially  
if you are prepared for the call.  
To ensure your call’s overall success and expediency:  
1)  
2)  
Have the phone close to the PC so you can conveniently and quickly take  
action that the Applications Engineer might suggest.  
Be prepared to open your PC, remove boards, report back-switch or  
jumper settings, and possibly change settings before reinstalling the  
modules.  
3)  
Have a volt meter handy to take measurements of the signals you are  
trying to measure as well as the signals on the board, module, or power  
supply.  
4)  
5)  
Isolate problem areas that are not working as you expected.  
Have the source code to the program you are having trouble with available  
so that preceding and prerequisite modes can be referenced and  
discussed.  
6)  
Have the manual at hand. Also have the product’s utility disks and any  
other relevant disks nearby so programs and version numbers can be  
checked.  
Preparation will facilitate the diagnosis procedure, save you time, and avoid  
repeated calls. Here are a few preliminary actions you can take before you call  
which may solve some of the more common problems:  
1)  
2)  
Check the PC-bus power and any power supply signals.  
Check the voltage level of the signal between SIGNAL HIGH and SIGNAL  
LOW, or SIGNAL+ and SIGNAL– . It CANNOT exceed the full scale range  
of the board.  
3)  
Check the other boards in your PC or modules on the network for address  
and interrupt conflicts.  
4)  
Refer to the example programs as a baseline for comparing code.  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT USA  
11  
P: (203) 483-8815; F: (203) 483-9024  
GDR 15L Series  
CyberResearch® Displays  
Intentionally Blank  
12  
GDR 15L Series  
CyberResearch® Displays  
GDR 15L Series  
Warranty Notice  
CyberResearch, Inc. warrants that this equipment as furnished will be free from  
defects in material and workmanship for a period of one year from the confirmed  
date of purchase by the original buyer and that upon written notice of any such  
defect, CyberResearch, Inc. will, at its option, repair or replace the defective item  
under the terms of this warranty, subject to the provisions and specific exclusions  
listed herein.  
This warranty shall not apply to equipment that has been previously repaired or  
altered outside our plant in any way which may, in the judgment of the manufacturer,  
affect its reliability. Nor will it apply if the equipment has been used in a manner  
exceeding or inconsistent with its specifications or if the serial number has been  
removed.  
CyberResearch, Inc. does not assume any liability for consequential damages as a  
result from our products uses, and in any event our liability shall not exceed the  
original selling price of the equipment.  
The equipment warranty shall constitute the sole and exclusive remedy of any Buyer  
of Seller equipment and the sole and exclusive liability of the Seller, its successors  
or assigns, in connection with equipment purchased and in lieu of all other  
warranties expressed implied or statutory, including, but not limited to, any implied  
warranty of merchant ability or fitness and all other obligations or liabilities of seller,  
its successors or assigns.  
The equipment must be returned postage prepaid. Package it securely and insure it.  
You will be charged for parts and labor if the warranty period has expired.  
Returns and RMAs  
If a CyberResearch product has been diagnosed as being non-functional, is visibly  
damaged, or must be returned for any other reason, please call for an assigned  
RMA number. The RMA number is a key piece of information that lets us track and  
process returned merchandise with the fastest possible turnaround time.  
PLEASE CALL FOR AN RMA NUMBER!  
Packages returned without an RMA number will be refused!  
In most cases, a returned package will be refused at the receiving dock if its  
contents are not known. The RMA number allows us to reference the history of  
returned products and determine if they are meeting your application’s requirements.  
When you call customer service for your RMA number, you will be asked to provide  
information about the product you are returning, your address, and a contact person  
at your organization.  
Please make sure that the RMA number is prominently  
displayed on the outside of the box.  
• Thank You •  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT USA  
13  
P: (203) 483-8815; F: (203) 483-9024  
GDR 15L Series  
CyberResearch® Displays  
Intentionally Blank  
14  
GDR 15L Series  
CyberResearch, Inc.  
25 Business Park Drive  
Branford, CT 06405 USA  
P: (203) 483-8815; F: (203) 483-9024  

Grandstream Networks Dect Ip Accessory Handset And Charger DP710 User Manual
Fujitsu Computer Monitor A17 2 DVI User Manual
Epson TC 1428 User Manual
Epson C82069_ User Manual
Electrolux U05011 mixed km 6 24 User Manual
Electrolux Air O Convect AOS202GCD1 User Manual
DeLonghi Convection Oven 1761030IDL User Manual
Dell M783c User Manual
Black Box Computer Hardware LEH1008A 2MMSC User Manual
Asus Computer Monitor VB195 User Manual