INSTALLATION INSTRUCTIONS
HB0037
MODEL E662
!
!
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)
V06800 rev. F
TABLE OF CONTENTS
BROAN ELITE E662 HOOD SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1. INSTALL DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2. PREPARE THE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3. CABINET PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4. CUTTING HOLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
5. PREPARE THE HOOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6. INSTALL THE HOOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8
7. CABINET BLOWER PREPARATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
8. INSTALL THE BLOWER IN THE CABINET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
9. CONNECT WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
10.REINSTALL SIDE PANELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
11. LIGHT BULBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
12. OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
13. USE AND CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
14. WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
15. SERVICE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
16. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
- 3 -
BROAN ELITE E662
HOOD SYSTEM
Model 634 or 644
(roof cap)
Model 647
Model 634 or 644
(roof cap)
Model 643
(8” Rd wall cap)
(7” Rd wall cap)
Model 412
8” round
adjustable
elbow
Model 415
7”
adjustable
elbow
transition
Model 459
transition
(3¼” x 10”
to 7” round)
(optional)
(3¼” x 14”
to 8” round)
(optional)
Model 407
7” Round
standard
duct
8” Round
standard
duct
3¼” x 14”
rectangular
standard
duct
Model 459
transition
(3¼” x 14”
to 8” round)
3¼” x 10”
rectangular
standard
duct
Model T460
transition
(3¼” x 14”
to 7” round)
Model T461
Adapter and damper 3¼” x 14”
to 3¼” x 10” (optional)
Adapter and damper 3¼” x 14”
(supplied with hood)
Left and right
flow deviators
(supplied with cabinet blower)
Cabinet blower
(supplied with hood)
BROAN ELITE E662 HOOD
HL0055
- 4 -
1. INSTALL DUCTWORK
Plan where and how the ductwork will be installed. Install proper-sized ductwork, elbows and roof or wall cap for the type
of blower you are installing. Use 2” duct tape to seal duct joints.
NOTE: When performing vertical exhaust ductwork, there must be at least 14” high free inside cabinet in order to
allow cabinet blower installation.
The minimum hood distance above cooktop must not be less than 24”. A maximum of 30” above cooktop is
highly recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion.
Roof cap
Roof cap
3¼” x 14” duct
OR 3¼” x 10”
7” OR 8” round duct
Transition model 459
3¼” x 14” to 8” OR
model T460
3¼” x 14” to
3¼” x 10” adaptor
model T461 (optional)
Wall
cap
3¼” x 14” to 7”
Cabinet blower
Wall
cap
Cabinet blower
Hood
Hood
24” minimum above
cooking surface
24” minimum above
cooking surface
HH0046A
HH0045A
2. PREPARE THE INSTALLATION
Make sure that the following items are included:
- Hood
- Accessories:
• Filters (2 for 30’’ and 36’’ width hoods, 3 for 42’’ width hood)
• Cabinet blower including left and right flow deviators (assembled to cabinet blower)
• Electrical cable with 3-prong redeptacle (inside one filler)
• 3¼” x 14” adapter/damper (inside one filler)
• Bag of parts (inside one filler) including:
(2) wire clamps, (5) no. 8 x 1/2” screws, (3) wire connectors, (9) no. 8 x 3/8” screws
Parts sold separately:
- Halogen lights (MR16, GU10, 120 V, 50 W)
- Transition 3¼” x 14” to 8” round model no. 459 (optional), transition 3¼” x 14” to 7” round model no. T460 (optional),
adaptor/damper 3¼” x 14” to 3¼” x 10” model T461 (optional), ducts, elbows, dampers, wall and roof caps. Refer to
page 4 for a complete list of venting options and model numbers.
NOTES: 1. During installation, protect countertop and/or cooktop.
2. If the bottom of the cabinet is recessed, attach three 1’’ width wood strip (not included). Refer to figure below
for wood strips proper location.
CABINET BOTTOM
1”
1”
1”
10¼’’
1¾’’
1¾’’
HO0045A
- 5 -
3. CABINET PREPARATION
WARNING
!
The cabinet must be sized to support the total weight of the hood. For the E662 hood model, the
total weight is 41 lb (19 kg).
If the cabinet need to be reinforced, we suggest to add wood blocks the
strengthen the connection between the bottom of the cabinet and its sides,
as shown beside.
ADD WOOD BLOCKS
HD0139
4. CUTTING HOLES
See figures below for cut-out dimensions in the bottom of the cabinet.
30” CABINET BOTTOM
36” CABINET BOTTOM
C
L
C
L
24½”
24½”
¾”
2”
10”
10”
4½”
4½”
1¼’’
1’’
1’’
1½”
42” CABINET BOTTOM
C
L
24½”
2”
10”
4½”
1¼’’
1’’
1½”
HO0040A
See figures below for cut-out dimensions for ducting.
HORIZONTAL DISCHARGE
VERTICAL DISCHARGE
C
L
FRONT
C
L
BACK OF CABINET
TOP OF CABINET
7¼’’ 7¼’’
3¾”
1½’’
3¾”
7¼’’ 7¼’’
3¼’’
HH0050A
HH0051A
- 6 -
5. PREPARE THE HOOD
SCREW LOCATION
5.1 Remove filters from the hood. Remove (3) screws holding both side
panels to the hood and set aside. Remove both side panels.
3
2
1
HO0042
5.2 Punch out 2 knock-out holes for electrical connections (2 on top or one on top and one on back of the hood).
5.3 Attach one wire clamp on top of the hood for the provided electrical cable with 3-prong plug. Through the wire
clamp, insert this electrical cable in the hood and tighten the wire clamp to secure the cable.
5.4 Connect cable wires as follow: BLUE wire with red connector to BLUE
wire with red connector (A), BROWN wire with red connector to
BLACK wire with red connector (B), GREEN wire under ground screw (C).
B
DO NOT FORGET TO CONNECT THE GROUND.
A
C
HE0052
6. INSTALL THE HOOD
6.1 Run power cable to installation location. Position the hood in its intended location. Using a pen mark the position
of the screws (smaller part of the keyholes, see pictures below for the (5) keyholes locations). Remove the hood.
6.2 Install (4) no. 8 x 1/2” screws, leaving a 1/8” gap (do not install the no. 5 screw yet).
3
1
5
3
1
2
4
HD0129
2
4
HD0127
HD0128
- 7 -
6. INSTALL THE HOOD (CONT’D)
6.3 Attach the second wire clamp, insert the power cable in the hood and tighten the wire clamp to secure the cable.
Place the hood under the cabinet and slide it in position. Run power cable from hood up through slot cut in cabinet.
Tighten the (4) screws completely, the add the last scerw (scerw no 5) in the center keyhole.
7. CABINET BLOWER PREPARATION
7.1 VERTICAL DISCHARGE ONLY
7.1.1 Seal the metal shutoff plate on the back of the cabinet
blower using duct tape.
7.2 HORIZONTAL DISCHARGE ONLY
HD0130
7.2.1 The cabinet blower included with the E662 model is factory
set to exhaus vertically. If the horizontal discharge is
chosen, remove the metal shutoff plate from back of the
hood, by removing the 3 screws. Set aside screws. Discard
both left and right plastic diverters assembled to the metal
shut off plate.
HD0131
7.2.2 Press the metal shutoff plate on a surface to completely flatten
bent flange and install on the top of the blower, using the
3 screws previously set aside plus another no. 8 x 1/2” screw
(from parts bag).
HD0119
7.2.3 Fold down the foldable flange of the adapter/damper. This flange must be
at 90° from the remaining flanges. See picture beside.
HD0112
7.2.4 Using three (3) no. 8 x 1/2” screws provided with hood,
secure the adapter to the back of the cabinet blower.
Remove tape from damper flap. Seal the adapter and the
metal shutoff plate to the cabinet blower using duct tape.
HD0132
- 8 -
8. INSTALL THE BLOWER IN THE CABINET
8.1
Install the cabinet in the cabinet and rest it on th e adapter plate. If a framed cabinet is used, insert the blower
as show in pictures below.
STEP 1
STEP 2
HH0052
HH0053
STEP 3
HH0054
8.2 VERTICAL DISCHARGE ONLY
8.2.1 Using four (4) no. 8 x 1/2” screws provided with hood, secure the
adapter to the top of the cabinet below. Remove tape from damper
flap. Seal the adapter to the cabinet below using tape.
HO0043
8.3 ALL DISCHARGE TYPES
2
1
8.3.1 From inside the hood, secure the blower to the adaptor plate of the
SCREW LOCATIONS
hood using five (5) no 8 x 3/8 screws.
4
5
3
HO0044
8.3.2 Plug the cabinet blower to the hood receptacle.
HE0053
- 9 -
9. CONNECT WIRING
!
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
Connect cable into wiring box using provided wire connectors.
Connect wires as follow: WHITE to WHITE (A), BLACK TO BLACK
(B), and GREEN or BARE wires under GREEN ground screws (C).
DO NOT FORGET TO CONNECT THE GROUND.
A
B
HE0082
10.REINSTALL SIDE PANELS
Reinstall both side panels, using 3 screws per side (saved from step 5), as
shown beside.
SCREW LOCATION
CAUTION
3
2
1
HO0042
Remove protective plastic film covering filters before
installing them.
Reinstall filters.
- 10 -
11.LIGHT BULBS
This hood must use 120V, 50W max., type MR16, GU10 shielded halogen lamps. (Purchase separately).
WARNING
!
In order to prevent the risk of personal injury, do not install a lamp identified for use only in
enclosed fixtures.
NOTE: The rings must be removed from bottom banel before installing halogen lamps.
11.1 Install the lamps by placing the bulb leads into their grooves in the socket
and gently push upward and turn clockwise until secured.
HE0047
11.2 Install trim rings by pushing upward.
HO0034
WARNING
!
In order to prevent the risk of personal injury, the halogen
lamps must be cooled down before removing them.
11.3 To remove lamps, gently push upwad and turn counterclockwise to
disengage bulb leads from their grooves.
HE0047
- 11 -
12.OPERATION
Always turn your blower on before you begin cooking to establish an air flow in the kitchen. Allow the blower run for a
few minutes to clear the air after you turn off the range.
HC0017
A
B
C
D
E
F
A) Blower OFF Delay touch pad
D) OFF lighting touch pad
B) ON / Blower speed control touch pad
E) Halogen light touch pad
C) OFF Blower touch pad / Filter maintenance touch pad
F) Nightlight / keyboard lock touch pad
A. BLOWER OFF DELAY TOUCH PAD:
When a speed is selected, touch the delay touch pad to activate the delay function. The corresponding speed indicator
LED will start flashing to indicate this function is activated. Touch once for a 5-minute delay, twice for 10-minute delay,
three times for 15-minute delay and four times for a 20-minute delay. The fan will continue to operate for the
programmed minutes and will stop automatically. To cancel the delay function, wait 2 seconds and touch the delay
touch pad once again; the blower will then work in normal mode.
NOTE: The blower speed can be increased - or decreased - during delay mode without starting another delay cycle.
B. ON / BLOWER SPEED CONTROL TOUCH PAD:
Touch this touch pad to turn on the blower at the last selected speed. To change the blower speed, touch the touch pad
again until the desired speed is obtained.
NOTES: 1. Each time you touch on the speed control touch pad, the speed changes by increments of 1 (e.g.: speed
1 to speed 2, to speed 3, and then speed 4. From the fourth speed, goes down to speed 1).
2. The last speed used is kept in memory except the fourth, the next time the blower will be turned on, it will
run on speed 3.
HEAT SENTRY
This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower
if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.
When HEAT SENTRY is activated, the first and the last speed blower LEDs are flashing alternately.
When the temperature level drops to normal, the blower will return to its original setting.
WARNING
!
The HEAT SENTRY can start the blower even if the hood is turned OFF. In this case, it is impossible to
turn the blower OFF with blower switch. If you must stop the blower, do it from the main electrical panel.
C. OFF BLOWER / FILTER MAINTENANCE TOUCH PAD:
Touch this touch pad to turn off the blower.This command also cancels the delay function (if activated).
NOTE: After 25 hours of operation, all blower LEDs will flash during 30 seconds to indicate the filters need to be
cleaned in order to maintain efficient hood operation. The LEDS will continue to flash until the function is
reset by pressing on this touch pad for 3 seconds.
D. OFF LIGHTING TOUCH PAD:
Touch this touch pad to turn off lighting.
E. HALOGEN LIGHT TOUCH PAD:
Touch this touch pad to turn on the halogen lamps.The lighting intensity changes by increments of 1 (e.g.:Touch once for low
intensity, once again to get more, up to three times. From the higher intensity, touch once to go back to the lower intensity).
NOTE: The last lighting intensity used is kept in memory. The next time the halogen lamps will be turned on, they will
light with the last intensity used.
F. NIGHTLIGHT / KEYBOARD LOCK TOUCH PAD:
Touch this touch pad to activate the nightlight. The LED will light to indicate the nightlight is on.
When cleaning the hood, use the keyboard lock. To activate the keyboard lock, touch on this touch pad during 3 seconds;
the LED will flash to indicate the keyboard lock is on. Touch on the touch pad and hold for 3 seconds again to stop the
keyboard lock function.
NOTES: 1. When cleaning the hood, never spray cleaning agent directly on the controls; spray it on the cleaning
cloth and wipe the control with it. Spraying cleaning agent directly on the control will cause
unexpected keyboard activation.
2. When the keyboard lock is on, it stops the HEAT SENTRY.
3. If there a temporary power failure when the keyboard lock is on, when the power will be restored, the
keyboard lock will still be on.
- 12 -
13.USE AND CARE
Grease filters and side panels.
The grease filters and the bottom panel should be cleaned frequently. Use a warm detergent solution.
Remove grease filters by pushing them towards the back of hood and rotating downward.
Clean all-metal filters in the diswasher using a non-phophate detergent. Discoloration of the filter may occur if using
phosphate detergents, or as a result of local water conditions — but this will not affect filter performance. This discoloration
is not covered by the warranty.
When cleaning the hood, never spray cleaning agent directly on the controls; spray it on the cleaning cloth and
wipe the control with it. Spraying cleaning agent directly on the control will cause unexpected keyboard activation.
STAINLESS STEEL CLEANING:
Do: - Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.
- Always clean in the direction of original polish lines.
- Always rinse well with clear water (2 or 3 times) after cleaning. Wipe completely dry.
- You may also use a specialized household stainless steel cleaner.
Don’t: -Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.
- Do not use any harsh or abrasive cleasers.
- Do not allow dirt to accumulate.
- Do not let plaster dust or any construction residues reach the hood. During construction or renovation, cover
the hood to make sure no dust sticks to stainless steel surface.
Avoid: when choosing a detergent
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive
and should never be used close to a range.
PAINTED FINISH:
Clean with warm water and mild detergent only. If discoloration occurs, use a good enamel polish such as automotive
polish. (DO NOT use rough abrasive cleaner or porcelain cleaner).
- 13 -
14.WIRING DIAGRAM
!
WARNING
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with
all applicable codes and standards. Before connecting wires, switch power off at service panel and
lock service disconnecting means to prevent power from being switched on accidentally.
120 V Supply
J5
3
2
Line
Return
Ground
BK
W
BK
nc
BK
1
W
W
Light Socket
50W max.
BL
J6
3
2
1
W
Y
Y
BK
nc
W
Y
Light Socket
50W max.
Note
3
BL
BN
(2)
IEC-320
C14 Plug
J4
4
G
3
BK
Y [120]
[70]
[50]
nc
nc
BK
R
R
P
3
2
1
Blower pack #15931
Fan Motor no 2 Fan Motor no 1
P
3
(2)
IEC-320 \
C13 Socket
BL [35]
O [0]
BN
BL
BL
BK
BK
BL
W
W
nc
ELECTRONIC
ASSEMBLY
BN
BN
BL
<ref>
BK
A1
Main power board
ncY [120]
W
BK
J2
nc
G
G
R
P
[70]
[50]
G
16
BL [35]
O [0]
ELECTRONIC
ASSEMBLY
User Interface
W
W
nc
A2
<ref>
-t°
Heat Sentry
WIRING COLOR CODE
NOTES
1. If any of the original wire, as supplied, must be replaced, use the
same equivalent wire.
2. Field wiring must comply with applicable codes, ordinances and
regulations.
BK BLACK
BL BLUE
BN BROWN
P
R
W
Y
PURPLE
RED
WHITE
G
O
GREEN
ORANGE
YELLOW
nc no connection
3. Marked black conductor, for blower wiring.
HE0043A
- 14 -
15. SERVICE PARTS
E662 MODEL
1
2
3
4
5
6
9
7
8
9
12
13
10
10
HL0056
11
KEY
no.
PART
NUMBER
WIDTHS
30’’ 36’’ 42’’
DESCRIPTION
1
1
1
1
1
1
1
1
2
2
2
-
1
2
1
-
-
1
1
1
1
1
1
1
1
1
1
2
2
-
2
1
2
-
1
-
1
1
1
1
1
1
1
1
2
2
3
-
1
2
3
4
5
6
7
8
9
V14971
V06242
V06243
V15931
V06263
V06262
V06750
V06741
V05917
V06268
V06265
V06266
V06733-2
V05921
V06734
V06745
V06746
V06776
V06784
V06800
ADAPTER/DAMPER
LEFT FLOW DEVIATOR
RIGHT FLOW DEVIATOR
CABINET BLOWER
CONTROL PCB
CONTROL FASCIA
BROAN ELITE LOGO
TRANSFORMER AND HARNESS KIT
LAMP SOCKET
TRIM RING
FILTERS 9.922” X 17.981”
FILTERS 12.922” X 17.981”
CONTROL PROCESSOR UNIT
HALOGEN LAMP 50W, 120V, GU-10
LOW VOLTAGE HARNESS
LOW VOLTAGE HARNESS
LOW VOLTAGE HARNESS
BLOWER CORD
10
11
1
2
-
12
13
*
-
1
1
1
*
*
*
*
1
1
1
HOOD CORD
1
1
INSTALLATION MANUAL
PARTS BAG ((2) wire clamps, (3)
wire connectors, ((5) no. 8 x 1/2”
screws, (9) no. 8 x 3/8” screws)
1
1
1
V06752
*
* Item not shown.
- 15 -
16. WARRANTY
WARRANTY
BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY
Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free
from defects in materials or workmanship for a period of one year from the date of original purchase.THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product
or part which is found to be defective under normal use and service.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been
subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-Nutone LLC),
faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some
states or provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not
apply to you.
BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION,
SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-
NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states or
provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state
or province to another. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone LLC at one of the addresses or telephone numbers
stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the
product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
Broan-NuTone Canada Inc., 1140 Tristar Drive, Mississauga, ON L5T 1H9 (1-888-882-7626)
- 16 -
|