Black Box Computer Hardware LPB1305A User Manual

LPB1305A
5-Port PoE+ Gigabit Ethernet Switch User’s Manual  
Provides four PoE+ ports and one uplink port.  
Each port can use a power supply up to 30 W, and the total PoE budget  
is 62 W.  
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)  
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax  
724-746-0746 • Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence,  
PA 15055-1018 • Web site: www.blackbox.com • E-mail: [email protected]  
Customer  
Support  
Information  
FCC and IC RFI Statements/NOM Statement  
FEDERAL COMMUNICATIONS COMMISSION AND  
INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS  
This equipment generates, uses, and can radiate radio-frequency energy,  
and if not installed and used properly, that is, in strict accordance with the  
manufacturer’s instructions, may cause interference to radio communication.  
It has been tested and found to comply with the limits for a Class A computing  
device in accordance with the specifications in Subpart B of Part 15 of FCC rules,  
which are designed to provide reasonable protection against such interference  
when the equipment is operated in a commercial environment. Operation of  
this equipment in a residential area is likely to cause interference, in which case  
the user at his own expense will be required to take whatever measures may be  
necessary to correct the interference.  
Changes or modifications not expressly approved by the party responsible  
for compliance could void the user’s authority to operate the equipment.  
This digital apparatus does not exceed the Class A limits for radio noise  
emission from digital apparatus set out in the Radio Interference Regulation  
of Industry Canada.  
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les  
limites applicables aux appareils numériques de la classe A prescrites dans le  
Règlement sur le brouillage radioélectrique publié par Industrie Canada.  
Normas Oficiales Mexicanas (NOM)  
Electrical Safety Statement  
INSTRUCCIONES DE SEGURIDAD  
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes  
de que el aparato eléctrico sea operado.  
2. Las instrucciones de seguridad y operación deberán ser guardadas para  
referencia futura.  
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de  
operación deben ser respetadas.  
4. Todas las instrucciones de operación y uso deben ser seguidas.  
Page 3  
724-746-5500 | blackbox.com  
NOM Statement  
5. El aparato eléctrico no deberá ser usado cerca del aguapor ejemplo,  
cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca,  
etc.  
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales  
que sean recomendados por el fabricante.  
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea  
recomendado por el fabricante.  
8. ServicioEl usuario no debe intentar dar servicio al equipo eléctrico más allá  
lo descrito en las instrucciones de operación. Todo otro servicio deberá ser  
referido a personal de servicio calificado.  
9. El aparato eléctrico debe ser situado de tal manera que su posición no  
interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá,  
alfombra o superficie similar puede bloquea la ventilación, no se debe  
colocar en libreros o gabinetes que impidan el flujo de aire por los orificios  
de ventilación.  
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor  
como radiadores, registros de calor, estufas u otros aparatos (incluyendo  
amplificadores) que producen calor.  
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo  
del tipo descrito en el instructivo de operación, o como se indique en el  
aparato.  
12. Precaución debe ser tomada de tal manera que la tierra fisica y la  
polarización del equipo no sea eliminada.  
13. Los cables de la fuente de poder deben ser guiados de tal manera que no  
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,  
poniendo particular atención a los contactos y receptáculos donde salen  
del aparato.  
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las  
recomendaciones del fabricante.  
15. En caso de existir, una antena externa deberá ser localizada lejos de las  
lineas de energia.  
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea  
usado por un largo periodo de tiempo.  
Page 4  
724-746-5500 | blackbox.com  
NOM Statement  
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean  
derramados sobre la cubierta u orificios de ventilación.  
18. Servicio por personal calificado deberá ser provisto cuando:  
A: El cable de poder o el contacto ha sido dañado; u  
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o  
C: El aparato ha sido expuesto a la lluvia; o  
D: El aparato parece no operar normalmente o muestra un cambio en su  
desempeño; o  
E: El aparato ha sido tirado o su cubierta ha sido dañada.  
Page 5  
724-746-5500 | blackbox.com  
Table of Contents  
Table of Contents  
1.  
2.  
Specifications......................................................................................... 7  
Overview ............................................................................................... 8  
2.1 Introduction ................................................................................ 8  
2.2 What’s Included.......................................................................... 8  
2.3 Hardware Description.................................................................. 8  
3. Installation............................................................................................10  
4. Operation.............................................................................................11  
Page 6  
724-746-5500 | blackbox.com  
Chapter 1: Specifications  
1. Specifications  
Approvals  
FCC, CE  
Buffer Memory 104K bits  
Filtering/  
Forwarding  
Rates  
1000 Mbps port: 1,488,000 pps;  
100 Mbps port: 148,800 pps;  
10 Mbps port: 14,880 pps  
MAC Address  
1 K  
Power over  
Ethernet  
Supports up to 30 W for each PoE port;  
PoE power budget: 62 W;  
PD classification identify;  
PoE overcurrent protection,  
PoE circuit sorting protection,  
PoE power on RJ-45 pins 3, 6 for power +, pins 1, 2 for power -  
Standards  
IEEE 802.3: 10BASE-T;  
IEEE 802.3u: 100BASE-TX;  
IEEE 802.3ab:1000BASE-TX;  
IEEE 802.3at/af: Power Over Ethernet  
Transmission  
Media  
10BASE-T CAT3, 4, 5 UTP/STP;  
100BASE-TX CAT 5 UTP/STP;  
1000BASE-TX: CAT5e/6/7 UTP/STP  
Transmission  
Method  
Store and Forward  
Connectors  
(4) RJ-45 PoE+ ports;  
(1) RJ-45 uplink port;  
Power connector  
Indicators  
(10) LEDs:  
(1) Power,  
(1) Uplink,  
(4) LAN port,  
(4) PoE port  
Environment  
Temperature: Operating: 32 to 122° F (0 to 50° C);  
Humidity: 10 to 90% relative, noncondensing  
Power  
100–240 VAC, 50/60 Hz internal power module  
1.5"H x 4.5"W x 7.1"D (3.7 x 11.3 x 18 cm)  
1.8 lb. (0.8 kg)  
Dimensions  
Weight  
Page 7  
724-746-5500 | blackbox.com  
Chapter 2: Overview  
2. Overview  
2.1 Introduction  
The 5-Port PoE+ Gigabit Ethernet Switch (LPB1305A) has four PoE+ ports and one uplink  
port. With PoE+, each port can use a power supply up to 30 W, and the total PoE budget  
is 62 W.  
2.2 What’s Included  
Your package should include the following items. If anything is missing or damaged,  
contact Black Box Technical Support at 724-746-5500 or [email protected].  
• (1) PoE+ Switch  
• (1) power cord  
• A printed Quick Start Guide  
NOTE: To download the user manual (the document you are reading now), go to  
search bar.  
2.3 Hardware Description  
1 2  
3
4
Figure 2-1. Front panel.  
5
6
7
Figure 2-2. Back panel.  
Page 8  
724-746-5500 | blackbox.com  
Chapter 2: Overview  
Table 2-1. PoE+ switch components.  
Number in Component Description  
Figure 2-1  
or 2-2  
1
2
(1) Power LED Lights green when power is on and normal.  
(1) LAN LED  
Lights green/orange on when the 10/100/1000  
Ethernet uplink port is connected.  
3
4
(4)  
Flashes orange when the port is transferring data  
10/100/1000 at 1000 Mbps.  
LEDs  
Flashes green when the port is transferring data at  
100 Mbps.  
Off when the port is transferring data at 10 Mbps.  
(4) PoE+  
LEDs  
Lights orange when the Power over Ethernet (PoE)  
function on port x (where x=1–4) is active.  
Off when PoE on the port 1–4 is disabled.  
5
6
7
(1) 3-prong  
connector  
Links to 110–240 VAC power cord.  
(1) RJ-45  
connector  
Link Port 1: Connects to a network via CAT5e/6/7  
cable.  
(4) RJ-45  
connectors  
Ports 2–5: Link to Powered Devices (PD) for Power  
over Ethernet (PoE).  
Page 9  
724-746-5500 | blackbox.com  
Chapter 3: Installation  
3. Installation  
STEP 1: Connect the AC power cord to the PoE+ switch, and the Power LED will  
light.  
STEP 2: Link Port 1 on the PoE+ switch to a network connection via CAT5e/6/7  
cable.  
STEP 3: Attach the four PoE+ ports on up to four Powered Devices (PDs) to the  
four PoE+ ports on the PoE+ switch.  
Figure 3-1 shows an application diagram.  
Gigabit Ethernet  
Access Point  
Up to 328 feet (100 m)  
of CAT5e/6/7 cable  
PoE  
PoE  
Up to 328 feet (100 m)  
of CAT5e/6/7 cable  
5-Port PoE+ Gigabit  
Ethernet Switch  
(LPB1305A)  
Gigabit Ethernet  
Access Point  
PoE  
Up to 328 feet (100 m)  
of CAT5e/6/7 cable  
Up to 328 feet (100 m)  
of CAT5e/6/7 cable  
Gigabit Ethernet  
PoE splitter  
Gigabit Ethernet  
Access Point  
PC  
Figure 3-1. Typical installation.  
Page 10  
724-746-5500 | blackbox.com  
Chapter 4: Operation  
4. Operation  
Once installed, the switch operates automatically. LED indicators function as  
described in Table 4-1.  
Table 4-1. LED indicators on the LPB1305A PoE+ Switch.  
Indicator  
Function  
(1) Power LED  
(1) LAN LED  
Lights green when power is on and normal.  
Lights green/orange on when the 10/100/1000 Ethernet  
uplink port is connected.  
(4) 10/100/1000 Flashes orange when the port is transferring data at 1000  
LEDs  
Mbps.  
Flashes green when the port is transferring data at 100  
Mbps.  
Off when the port is transferring data at 10 Mbps.  
(4) PoE+ LEDs  
Lights orange when the Power over Ethernet (PoE)  
function on port x (where x=1–4) is active.  
Off when PoE on the port 1–4 is disabled.  
Page 11  
724-746-5500 | blackbox.com  
Black Box Tech Support: FREE! Live. 24/7.  
Tech support the  
way it should be.  
Great tech support is just 30 seconds away at  
724-746-5500 or blackbox.com.  
About Black Box  
Black Box provides an extensive range of networking and infrastructure products.  
You’ll find everything from cabinets and racks and power and surge protection  
products to media converters and Ethernet switches all supported by free, live 24/7  
Tech support available in 30 seconds or less.  
© Copyright 2013. Black Box Corporation. All rights reserved. Black Box® and the Double Diamond logo  
are registered trademarks of BB Technologies, Inc. Any third-party trademarks appearing in this manual  
are acknowledged to be the property of their respective owners.  
LPB1305A user manual, version 1  
724-746-5500 | blackbox.com  

Hanns G HG 216D Series User Manual
Frigidaire 318200657 User Manual
Equipex FC 26, FC 34, CN 34 User Manual
Electrolux KCG800 User Manual
Disney DT1900 P User Manual
DCS RGS 486GD User Manual
Cypress CY62148EV30 User Manual
Cypress CY7C1522AV18 User Manual
BenQ FP2091 User Manual
AT T E5902B User Manual