| TEST   PutON-TIMEswitchonthesensorbottomto   TEST and the Dual Light Level (ACCENT)   switch OFF.   ON-TIME   ACCENT   GUARDIAN   PRO™   TEST 1 5 20   Off 3 6 Dusk to Dawn   POST SENTRY   AUTO   Model PLMS   Set ON-TIME switch to   1, 5, or 20 minutes.   TEST 1 5 20 MIN   Features   • Light comes on when motion is detected.   • Automatically controls existing post light.   • Dual Light Level.   • Photocell keeps the light off during day-   light hours.   MANUAL MODE   Manual mode only works at   night because daylight re-   turns the sensor to AUTO.   This package includes:   Flipthelightswitchoffforone   secondthenbackontotoggle   betweenAUTOandMANUAL   MODE.   1 Second   OFF then...   Manual mode works only with   the ON-TIME switch in the 1,   5, or 20 position.   Post Light   3 Screws   Adapter   ... back on.   Mode Switching Summary   TEST   ON-TIME Switch at   3 Wire Connectors   1, 5, or 20 minutes   AUTO   Requirements   Flip light switch   off for 1 second   • The Light Control requires 120 volts AC.   • If you want to use Manual Override, the   control must be wired through a switch.   • Some codes require installation by a   qualified electrician.   MANUAL MODE   then on   * If you get confused while switching modes,   turnthepoweroffforoneminute,thenback   on. After the calibration time the control will   be in the AUTO mode.   OPERATION   Mode:   On-Time   Works: Day Night   Dual Light Level Control   Light comes on half bright for selected time   after dusk (Off, 3 hr., 6 hr., until dawn). If   motion is sensed, the light turns on full bright   for the ON-TIME (1, 5, or 20 minutes) then   returns to dim mode.   Test   Auto   5 Sec   1, 5, or 20 Min   To Dawn*   x x x x x Manual   Accent 3,6 Hr, to Dawn   * resets to Auto Mode at dawn.   240-031-A   © 2003 Atlas Lighting Products, Inc.   598-1095-01   ❒ ❒ When you have the desired coverage   angle make a pencil mark on the sensor   and post to mark the sensor position.   If you need to change the sensitivity,   temporarily lift the fixture and sensor to   make the adjustment. It may be neces-   sary to have a friend hold the fixture   whileadjustingthesensitivity. Toomuch   sensitivity may increase false triggering.   SettheamountofONTIMEyouwantthe   light to stay on after motion is detected.   (1, 5, or 20 minutes).   ADJUSTMENTS   ❒ Turn on the circuit breaker and light   switch.   1 NOTE: Sensor has a 1 /2 minute warm up   periodbeforeitwilldetectmotion.When   first turned on or when switching from   Manual to Auto mode wait 1 1/2 minute.   ❒ Avoid aiming the control at:   • Objects that change temperature rapidly,   such as heating vents and air condition-   ers. These heat sources could cause false   triggering.   • Areaswherepetsortrafficmaytriggerthe   control.   • Nearby large, light-colored objects   reflectinglightmaytriggertheshut-offfeature.   Do not point other lights at the sensor.   OFF 3   6 DUSK TO   TEST 1 5 20 MIN   HOUR DAWN   ❒ Set the Dual Light Level (ACCENT)   switch to the amount of time after dusk   you want the lights on at low level (Off, 3,   6 Hrs., Dusk-to-Dawn).   ❒ Put the sensor and fixture back in place.   Alignthepencilmarksmadeabove.Tighten   the three screws to secure the sensor.   150°   Securing Brass &   Plastic Post Lamps   5 ft.   (1.5 m)   ❒ ❒ Turn power off at circuit breaker.   Turn the post lamp to the desired loca-   tion. Using a #31 drill and the fixture as   a template slightly mark the location of   one of the fixture mounting holes. DO   NOT drill through the sensor plastic.   Lift the fixture off the sensor and keep   the wires away from where you need to   drill. Now finish drilling the first hole.   Set the fixture in position and install a   screw (provided) to hold the fixture.   Mark the remaining holes as above.   Removetheonescrewandliftthefixture   and drill the remaining holes as above.   Set the fixture in position and install all the   screws(3provided). Becarefultonotover   tightenthescrewsandstripouttheplastic.   30 ft.   (9.1 m)   Maximum   Range   Maximum   Coverage Angle   Thedetectorislesssensitivetomotiondirectly   towardsitandmoresensitivetoacrossmotion.   ❒ ❒ Motion   Motion   ❒ ❒ Sensor   Least Sensitive   Most Sensitive   ❒ ❒ Walk through the coverage area noting   where you are when the lights turn on.   Loosen the 3 clamp screws slightly and   turn the sensor head left or right to   change the coverage area.   598-1095-01   3 TROUBLESHOOTING GUIDE   If you experience a problem with your Light Control, first follow this guide. For additional assistance write to:   Atlas Lighting Products, Inc. • Customer Service Department • P.O. Box 2348 • Burlington, NC 27216   SYMPTOM   POSSIBLE CAUSE   SYMPTOM   POSSIBLE CAUSE   Light will   not come   on.   1. Light switch is turned off.   2. Bulb is loose or burned out.   3. Fuse is blown or circuit breaker is   turned off.   4. Daylight turnoff is in effect (Re-   check after dark).   5. Incorrect circuit wiring, if this is a   new installation.   6. Re-aim the sensor to cover de-   sired area.   Light stays on 1. The sensor is pointed at nearby   continuously.   objectsthatcauseheattotrigger   the sensor. (Aim the sensor   away from nearby objects).   2. The sensor is pointed toward a   heat source like an air vent,   dryer vent, or brightly-painted   heat-reflectivesurface.(Re-aim   sensor).   Light flashes   on and off.   1. Heat being reflected from other   objects may be affecting the   sensor. (Re-aim sensor).   Light comes 1. Light Control may be installed in   on in   a relatively dark location.   daylight.   2. LightControlisinTest.(Setcontrol   switch to an ON-TIME position).   2. LightControlisintheTestmode   and warming up. (Flashing is   normalundertheseconditions).   Light comes 1. Light Control may be sensing   on for no   apparent   reason.   small animals or automobile traf-   fic (Re-aim sensor).   2. Sensitivity is set too high. (Re-   duce sensitivity).   FIVE YEAR LIMITED WARRANTY   AtlasLightingProducts,Inc.warrantsagainstdefectsinmaterialsorworkmanshipforaperiodoffiveyearsfrom   the date of purchase for use, and agrees to repair or, at our option, replace a defective unit without charge for   either parts or labor. IMPORTANT: This warranty does not cover damage resulting from accident, misuse of   abuse, lack of reasonable care, the affixing of any attachment not provided with product, alteration of any   attachments factory installed, loss of parts or subjecting the fixture to any but the specified electrical service.   Thiswarrantydoesnotcoverfailureofthebulbduetoaccidents, abuse, misuse, vandalism, powersurges, and   acts of nature such as lightning damage. No responsibility is assumed for any special incidental or   consequential damages. Damages occurring during transit are not covered by this warranty-including UPS   shipments. To obtain warranty service, mail sales receipt as proof-of-purchase, date and a brief explanation   of the nature of the defect, to the address listed below. You will receive, by mail, a Return Goods Authorization   number and full instructions for returning defective merchandise. All returned goods must be accompanied   by a Return Goods Authorization number issued by Atlas Lighting Products, Inc.   NOTE: No other warranty, written or verbal, is authorized by Atlas Lighting Products, Inc. This warranty gives   you specific legal rights and you may also have other rights which vary from state to state. Some states do not   allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied   warranty lasts, so the above exclusion and limitations may not apply to you.   For information regarding replacement parts please write to:   Atlas Lighting Products, Inc.   Attn: Customer Service Department   P.O. Box 2348   Burlington, NC 27216   598-1095-01   4 |