Asus Motherboard P9D C 90SB0330M0UAY0 User Manual

P9D-C  
Series  
 
Contents  
iii  
Contents  
iv  
Contents  
Intel® Rapid Storage Technology enterprise SATA Option ROM Utility 5-5  
v
Contents  
Intel® Rapid Storage Technology enterprise (Windows) ......................5-13  
Installing the Intel® C22x MEI NULL HECI driver...................................6-23  
vi  
Notices  
Federal Communications Commission Statement  
This device complies with Part 15 of the FCC Rules. Operation is subject to the  
following two conditions:  
This device may not cause harmful interference, and  
This device must accept any interference received including interference that  
may cause undesired operation.  
This equipment has been tested and found to comply with the limits for a Class B  
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to  
provide reasonable protection against harmful interference in a residential installation.  
This equipment generates, uses and can radiate radio frequency energy and, if not  
installed and used in accordance with manufacturer’s instructions, may cause harmful  
interference to radio communications. However, there is no guarantee that interference  
will not occur in a particular installation. If this equipment does cause harmful  
interference to radio or television reception, which can be determined by turning the  
equipment off and on, the user is encouraged to try to correct the interference by one  
or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment to an outlet on a circuit different from that to which the  
receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
The use of shielded cables for connection of the monitor to the graphics card is required to  
assure compliance with FCC regulations. Changes or modifications to this unit not expressly  
approved by the party responsible for compliance could void the user’s authority to operate  
this equipment.  
Canadian Department of Communications Statement  
This digital apparatus does not exceed the Class B limits for radio noise emissions  
from digital apparatus set out in the Radio Interference Regulations of the Canadian  
Department of Communications.  
This class B digital apparatus complies with Canadian ICES-003.  
REACH  
Complying with the REACH (Registration, Evaluation,Authorization, and Restriction of  
Chemicals) regulatory framework, we publish the chemical substances in our products  
at ASUS REACH website at http://csr.asus.com/english/REACH.htm.  
vii  
 
Safety information  
Electrical safety  
To prevent electrical shock hazard, disconnect the power cable from the electrical  
outlet before relocating the system.  
When adding or removing devices to or from the system, ensure that the power  
cables for the devices are unplugged before the signal cables are connected.  
If possible, disconnect all power cables from the existing system before you  
add a device.  
Before connecting or removing signal cables from the motherboard, ensure that  
all power cables are unplugged.  
Seek professional assistance before using an adapter or extension cord. These  
devices could interrupt the grounding circuit.  
Make sure that your power supply is set to the correct voltage in your area. If  
you are not sure about the voltage of the electrical outlet you are using, contact  
your local power company.  
If the power supply is broken, do not try to fix it by yourself. Contact a qualified  
service technician or your retailer.  
Operation safety  
Before installing the motherboard and adding devices on it, carefully read all the  
manuals that came with the package.  
Before using the product, make sure all cables are correctly connected and the  
power cables are not damaged. If you detect any damage, contact your dealer  
immediately.  
To avoid short circuits, keep paper clips, screws, and staples away from  
connectors, slots, sockets and circuitry.  
Avoid dust, humidity, and temperature extremes. Do not place the product in any  
area where it may become wet.  
Place the product on a stable surface.  
If you encounter technical problems with the product, contact a qualified service  
technician or your retailer.  
viii  
 
DO NOT throw the motherboard in municipal waste. This product has been designed to enable  
proper reuse of parts and recycling. This symbol of the crossed out wheeled bin indicates that  
the product (electrical and electronic equipment) should not be placed in municipal waste.  
Check local regulations for disposal of electronic products.  
DO NOT throw the mercury-containing button cell battery in municipal waste. This symbol of the  
crossed out wheeled bin indicates that the battery should not be placed in municipal waste.  
Australia statement notice  
From 1 January 2012 updated warranties apply to allASUS products, consistent with  
the Australian Consumer Law. For the latest product warranty details please visit  
http://support.asus.com. Our goods come with guarantees that cannot be excluded  
under theAustralian Consumer Law. You are entitled to a replacement or refund for a  
major failure and compensation for any other reasonably foreseeable loss or damage.  
You are also entitled to have the goods repaired or replaced if the goods fail to be of  
acceptable quality and the failure does not amount to a major failure.  
If you require assistance please call ASUS Customer Service 1300 2787 88 or visit  
us at http://support.asus.com  
ix  
 
About this guide  
This user guide contains the information you need when installing and configuring  
the motherboard.  
How this guide is organized  
This user guide contains the following parts:  
Chapter 1: Product introduction  
This chapter describes the features of the motherboard and the new technologies  
it supports.  
Chapter 2: Hardware information  
This chapter lists the hardware setup procedures that you have to perform when  
installing system components. It includes description of the switches, jumpers,  
and connectors on the motherboard.  
Chapter 3: Powering up  
This chapter describes the power up sequence and ways of shutting down the  
system.  
Chapter 4: BIOS setup  
This chapter tells how to change system settings through the BIOS Setup menus.  
Detailed descriptions of the BIOS parameters are also provided.  
Chapter 5: RAID configuration  
This chapter provides instructions for setting up, creating, and configuring RAID  
sets using the available utilities.  
Chapter 6: Driver installation  
This chapter provides instructions for installing the necessary drivers for different  
system components.  
Appendix: Reference information  
This appendix includes additional information that you may refer to when  
configuring the motherboard.  
Where to find more information  
Refer to the following sources for additional information and for product and software  
updates.  
1.  
2.  
ASUS websites  
The ASUS website provides updated information on ASUS hardware and  
software products. Refer to the ASUS contact information.  
Optional documentation  
Your product package may include optional documentation, such as warranty  
flyers, that may have been added by your dealer. These documents are not  
part of the standard package.  
x
 
Conventions used in this guide  
To ensure that you perform certain tasks properly, take note of the following symbols  
used throughout this manual.  
DANGER/WARNING: Information to prevent injury to yourself when trying to  
complete a task.  
CAUTION: Information to prevent damage to the components when trying to  
complete a task  
IMPORTANT: Instructions that you MUST follow to complete a task.  
.
NOTE: Tips and additional information to help you complete a task.  
Typography  
Bold text  
Italics  
Indicates a menu or an item to select.  
Used to emphasize a word or a phrase.  
<Key>  
Keys enclosed in the less-than and greater-than sign means  
that you must press the enclosed key.  
Example: <Enter> means that you must press the Enter or  
Return key.  
<Key1> + <Key2> + <Key3> If you must press two or more keys simultaneously, the key  
names are linked with a plus sign (+).  
Example: <Ctrl> + <Alt> + <Del>  
Command  
Means that you must type the command exactly as  
shown, then supply the required item or value enclosed  
in brackets.  
Example: At DOS prompt, type the command line:  
format A:/S  
xi  
P9D-C Series Specifications Summary  
Model Name  
P9D-C/4L  
P9D-C/2L  
1 x Socket LGA1150  
Intel® Xeon® Processor E3-1200 v3 product  
Family  
Processor Support / System Bus  
Intel® Core™ i3 Processor Family*  
Core Logic  
Intel® C224 Chipset  
Form Factor  
Fan Speed Control  
Rack Ready  
ATX, 12 in. x 9.6 in.  
(Rack and Pedestal  
dual use)  
ASUS Features  
ASWM Enterprise  
Total Slots  
4 (2 Channels)  
Capacity  
Memory  
Maximum up to 32GB  
DDR3 1333/1600 ECC UDIMM  
6
Memory Type  
Total PCI/PCI-E Slots  
Slot Location 1  
Slot Location 2  
Slot Location 3  
Slot Location 4  
Slot Location 5  
Slot Location 6  
Slot Location 7  
1 x PCI 32bit/33 MHz  
1 x PCI 32bit/33 MHz  
1 x PCI-E x1 (x1 Gen2 link)  
1 x PCI-E x1 (x1 Gen2 link)  
1 x PCI-E x8 (x4 Gen3 link)  
1 x PCI-E x16 (x8 Gen3 link)  
MIO supported  
Expansion  
Slots (follow  
SSI Location #)  
1 x PIKE Slot for Storage expansion  
(x4 Gen3 link)  
Additional Slot 1  
Intel® C224:  
-
-
-
2 x SATA 3Gb/s ports  
4 x SATA 6Gb/s ports  
SATA Controller  
Storage  
Intel® Rapid Storage Technology Enterprise  
(RSTe) supports software RAID 0, 1, 10, & 5  
(Windows®)  
4 x Intel® I210AT  
2 x Intel® I210AT  
LAN  
Networking  
1 x Management LAN  
* Refer to www.asus.com for the complete list of supported CPUs.  
(continued on the next page)  
xii  
 
Model Name  
Graphic  
P9D-C/4L  
P9D-C/2L  
VGA  
Aspeed AST2300 + 32MB VRAM  
1
TPM Header  
24-pin ATX power connector  
8-pin ATX 12V power connector  
PSU Connector  
SATA DOM Power  
Connector  
4-pin power connector  
Management  
Header  
On-board header for optional management card  
1 x USB 3.0 pin header (up to 2 devices)  
1 x USB 2.0 pin header (up to 2 devices)  
1 x USB 2.0 pin header (Type A USB socket)  
Onboard I/O  
Connectors  
USB Connector/  
Header  
Fan Header  
SMBus  
5 x 4 pin headers  
1
1
Chassis Intruder  
Front LAN LED  
4
2
Serial Port Header  
VGA Header  
2
1
2 x USB 3.0  
2 x USB 2.0  
External USB Port  
VGA Port  
1
Rear I/O  
Connectors  
4 x GbE LAN  
1 Management LAN  
2 x GbE LAN  
1 Management LAN  
RJ-45  
PS/2 KB/Mouse  
Software  
1
ASWM Enterprise  
Management  
Solution  
Out of Band  
Remote  
Optional ASMB7-iKVM for KVM-over-Internet  
Management  
CPU Temperature  
FAN RPM  
Monitoring  
Operation temperature:  
10oC – 35oC (50oF – 95oF)  
Non operation temperature:  
-40oC – 70oC (-40oF – 158oF)  
Non operation humidity:  
Environment  
20% – 90% (Non condensing)  
** Specifications are subject to change without notice.  
xiii  
xiv  
Chapter 1:  
Product Introduction  
1.1  
Welcome!  
Thank you for buying an ASUS® P9D-C Series motherboard!  
The motherboard delivers a host of new features and latest technologies, making it  
another standout in the long line of ASUS quality motherboards!  
Before you start installing the motherboard and hardware devices on it, check the  
items in your package with the list below.  
1.2  
Package contents  
Check your motherboard package for the following items.  
Standard Gift Box Pack Standard Bulk Pack  
I/O Shield  
1
1
1
1
2
4
1
1
1
Plate for LGA1150  
--  
--  
--  
--  
1
SATA DOM Power cable  
SATA 3G cable  
Cables  
SATA 6G cable  
Support CD  
Application CD  
ASWM Enterprise SDVD  
1
Motherboard User Guide  
Documentation  
Packing Qty.  
1
1 pc per carton  
10 pcs per carton  
If any of the above items is damaged or missing, contact your retailer.  
Optional items  
Description  
PIKE 2008  
PIKE 2108  
PIKE 2208  
PIKE 9230  
ASMB7-iKVM  
LSI 8-port SAS 6G RAID card  
LSI 8-port SAS 6G HW RAID card  
LSI 8-port SAS 6G HW RAID card  
MARVELL 4-port SATA 6G RAID card  
Remote Management solution provides KVM over IP solution  
1-3  
ASUS P9D-C Series  
 
1.3  
Serial number label  
Before requesting support from the ASUS Technical Support team, you must take  
note of the motherboard's serial number containing 12 characters xxS2xxxxxxxx  
shown as the figure below. With the correct serial number of the product, ASUS  
Technical Support team members can then offer a quicker and satisfying solution  
to your problems.  
P9D-C Series  
Made  
in  
China  
合格  
xxS2xxxxxxxx  
1.4  
Special features  
1.4.1  
Product highlights  
Latest processor technology  
This motherboard supports the latest Intel® Xeon® E3-1200 v3/Core™ i3 processor  
series in LGA1150 package, which has memory and PCI Express controller  
integrated to support 2-channel (4 DIMMs) DDR3 memory and 16 PCI Express  
3.0 lanes. The Intel® Xeon® E3-1200 V3 Core™ i3 processor is one of the most  
powerful and energy efficient CPU in the world.  
Intel® Turbo Boost  
Intel® Turbo Boost opportunistically and automatically allows the processor to  
run faster than the marked frequency if the processor is operating below power,  
temperature and current limits. This technology increases performance of both  
multi-threaded and single-threaded workloads.  
Intel® Hyper Threading  
The thread-level parallelism on each processor makes more efficient use of the  
processor resources, higher processing throughout and improved performance on  
today's multi-threaded software.  
Intel® EM64T  
The motherboard supports Intel® processors with the Intel® EM64T (Extended  
Memory 64 Technology). The Intel® EM64T feature allows your computer to run on  
64-bit operating systems and access larger amounts of system memory for faster  
and more efficient computing.  
PCI Express 3.0  
PCI Express® 3.0 (PCIe 3.0) is the PCI Express bus standard that provides twice the  
performance and speed of PCIe 2.0. It provides an optimal graphics performance,  
unprecedented data speed, and seamless transition with its complete backward  
compatibility to PCIe 1.0/2.0 devices.  
1-4  
Chapter 1: Product introduction  
 
Intel® I210AT LAN Solution  
The motherboard comes with quad Gigabit LAN controllers (dual controllers for  
P9D-C/2L) and ports which provide a total solution for your networking needs. The  
onboard Intel® I210AT Gigabit LAN controllers use the PCI Express interface and  
could achieve network throughput close to Gigabit bandwidth.  
Enhanced Intel SpeedStep Technology (EIST)  
The Enhanced Intel SpeedStep Technology (EIST) intelligently manages the  
CPU resources by automatically adjusting the CPU voltage and core frequency  
depending on the CPU loading and system speed or power requirement.  
Serial ATA II technology  
The motherboard supports the Serial ATA II 3 Gb/s technology through the Serial  
ATA interface and Intel® C224 chipset. The Serial ATA II specification provides  
twice the bandwidth of the current Serial ATA products with a host of new  
features, including Native Command Queuing (NCQ), Power Management (PM)  
Implementation Algorithm, and Hot Swap. Serial ATA allows thinner, more flexible  
cables with lower pin count and reduced voltage requirements.  
Serial ATA III technology  
The motherboard supports the Serial ATA III 6 Gb/s technology through the Serial  
ATA interface and Intel® C224 chipset. Get enhanced scalability, faster data  
retrieval, double the bandwidth of current bus systems with up to 6Gbps data  
transfer rates.  
USB 2.0 technology  
The motherboard implements the Universal Serial Bus (USB) 2.0 specification that  
dramatically increases the connection speed from the 12 Mbps bandwidth on USB  
1.1 to a fast 480 Mbps on USB 2.0. USB 2.0 is backward compatible with USB 1.1.  
USB 3.0 technology  
The motherboard implements the Universal Serial Bus 3.0 (USB 3.0) that has  
a connection speed of up to 5 Gbps - ten times faster than USB 2.0. Backward  
compatible with USB 2.0, it also supports fast-charging of supported devices.  
Temperature, fan, and voltage monitoring  
The CPU temperature is monitored to prevent overheating and damage. The  
system fan rotations per minute (RPM) is monitored for timely failure detection.  
The chip monitors the voltage levels to ensure stable supply of current for critical  
components.  
1-5  
ASUS P9D-C Series  
DDR3 memory support  
The motherboard supports ECC UDIMM DDR3 memory that features data transfer  
rates of 1600/1333 MHz to meet the higher bandwidth requirements of server  
and workstation applications. The dual-channel DDR3 architecture boosts system  
performance, eliminates bottlenecks with peak bandwidth up to 25Gb/s, and  
dramatically reduces the memory voltage to just 1.5V compared to DDR2's memory  
voltage of 1.8V.  
1.4.2  
Innovative ASUS features  
ASUS Fan Speed technology  
The ASUS Fan Speed technology smartly adjusts the fan speeds according to the  
system loading to ensure quiet, cool, and efficient operation.  
PIKE (Proprietary I/O Kit Expansion)  
PIKE is an on-demand upgrade kit for users. This ASUS unique feature enables  
users to choose their preferred I/O solutions. ASUS provides multiple SAS solutions  
for different segments and purposes and PIKE saves lots of validation efforts and  
hardware cost for end users. Moreover, the special patent design offers multiple I/O  
solutions without occupying the Slot 6 in 1U system.  
ASUS MIO Audio card  
TheASUS MIO audio card is a discrete 8-channel high definition audio (High Definition  
Audio previously codenamed Azalia) CODEC that enables the clearest high quality  
audio output. It has jack-sensing feature, retasking functions, and multi-streaming  
technology that simultaneously send different audio streams to different destinations  
for high-end sound quality.  
1-6  
Chapter 1: Product introduction  
Chapter 2:  
Hardware Information  
2.1  
Before you proceed  
Take note of the following precautions before you install motherboard components or change  
any motherboard settings.  
Unplug the power cord from the wall socket before touching any component.  
Use a grounded wrist strap or touch a safely grounded object or a metal object, such  
as the power supply case, before handling components to avoid damaging them due  
to static electricity.  
Hold components by the edges to avoid touching the ICs on them.  
Whenever you uninstall any component, place it on a grounded antistatic pad or in the  
bag that came with the component.  
Before you install or remove any component, ensure that the power supply is switched  
off or the power cord is detached from the power supply. Failure to do so may cause  
severe damage to the motherboard, peripherals, and/or components.  
2-3  
ASUS P9D-C Series  
 
2.2  
Motherboard overview  
Before you install the motherboard, study the configuration of your chassis to ensure that the  
motherboard fits into it.  
To optimize the motherboard features, we highly recommend that you install it in an ATX 1.1  
compliant chassis.  
Ensure to unplug the chassis power cord before installing or removing the motherboard.  
Failure to do so can cause you physical injury and damage motherboard components!  
2.2.1  
Placement direction  
When installing the motherboard, ensure that you place it into the chassis in the correct  
orientation. The edge with external ports goes to the rear part of the chassis as indicated in  
the image below.  
2.2.2  
Screw holes  
Place nine (9) screws into the holes indicated by circles to secure the motherboard to the  
chassis.  
DO NOT overtighten the screws! Doing so can damage the motherboard.  
Place this side towards  
the rear of the chassis  
2-4  
Chapter 2: Hardware information  
 
2.2.3  
Motherboard layout  
2-5  
ASUS P9D-C Series  
2-6  
Chapter 2: Hardware information  
2.2.4  
Layout contents  
Slots/Sockets  
Page  
2-9  
1.  
2.  
3.  
CPU sockets  
DDR3 sockets  
2-15  
2-18  
PCI Express x16 / PCI Express x8 / PCI Express x1 / PCI  
4.  
PIKE slot  
2-19  
Onboard LEDs  
Page  
2-23  
2-23  
2-24  
2-24  
2-25  
1.  
2.  
3.  
4.  
5.  
Standby Power LED (SB_PWR1)  
Baseboard Management Controller LED (BMC_LED1)  
CPU Warning LED (ERR_CPU1)  
Power LED (+5V_LED1)  
Location LED (LOCLED1)  
Jumpers  
Page  
2-26  
2-27  
1.  
2.  
3.  
Clear RTC RAM (CLRTC1)  
VGA controller setting (3-pin VGA_SW1)  
LAN controller setting  
(3-pin LAN_SW1, LAN_SW2, LAN_SW3, LAN_SW4)  
2-27  
2-28  
2-28  
4.  
RAID configuration utility selection (3-pin RAID_SEL1)  
5.  
Platform Environmental Control Interface (PECI) Setting  
(3-pin PECI1)  
Rear panel connectors  
Page  
2-29  
2-29  
2-29  
2-29  
2-29  
2-29  
2-29  
2-29  
2-29  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
9.  
PS/2 keyboard/mouse port (purple/green)  
RJ-45 port for iKVM  
Video Graphics Adapter port  
RJ-45 ports for LAN.  
Power-on Button  
Location LED  
Power LED  
USB 2.0 ports 1 and 2  
USB 3.0 ports 1 and 2  
2-7  
ASUS P9D-C Series  
Internal connectors  
Page  
1.  
Serial ATA 6.0/3.0 Gbps connector  
(7-pin 6Gbps SATA1, SATA2, SATA3, SATA4 �Light Blue)  
2-30  
(7-pin 3Gbps SATA5, SATA6 �Black)  
2.  
PSAS connectors  
(7-pin PSAS1, PSAS2, PSAS3, PSAS4, PSAS5, PSAS6, PSAS7, 2-31  
PSAS8 �Blue)  
3.  
4.  
5.  
6.  
USB 2.0 connector (10-1 pin USB78; A-Type USB9)  
USB 3.0 connector (20-1 pin USB3_34)  
2-32  
2-32  
2-33  
Thermal sensor cable connectors (3-pin TR1)  
CPU, front, and rear fan connectors  
(4-pin CPU_FAN1, FRNT_FAN1, FRNT_FAN2, FRNT_FAN3,  
REAR_FAN1)  
2-33  
7.  
Serial General Purpose Input/Output connector (6-1 pin  
SGPIO1)  
2-34  
PIKE Serial General Purpose Input/Output connectors  
(8-1 pin PSGPIO1, PSGPIO2)  
8.  
LAN34_LED connector (5-pin LAN34_LED1)  
Parallel port connector (26-1 pin LPT1)  
2-35  
2-35  
2-36  
2-36  
2-37  
2-37  
2-38  
2-39  
2-40  
2-41  
2-41  
9.  
10.  
11.  
12.  
13.  
14.  
15.  
16.  
17.  
18.  
Serial port connectors (10-1 pin COM1/COM2)  
Power Supply SMBus connector (5-pin PSUSMB1)  
Trusted Platform Module connector (20-1 pin TPM1)  
SATA DOM power connector (4-pin PWR3)  
ATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1)  
System panel connector (20-1 pin PANEL1)  
Auxiliary panel connector (20-2 pin AUX_PANEL1)  
VGA connector (16-pin VGA_HDR1)  
Hard disk activity LED connector (4-pin HDLED1)  
2-8  
Chapter 2: Hardware information  
2.3  
Central Processing Unit (CPU)  
The motherboard comes with a surface mount LGA1150 socket designed for the  
Intel® Xeon® E3-1200 v3/Core™ i3 processor.  
Upon purchase of the motherboard, ensure that the PnP cap is on the socket and  
the socket contacts are not bent. Contact your retailer immediately if the PnP cap  
is missing, or if you see any damage to the PnP cap/socket contacts/motherboard  
components. ASUS will shoulder the cost of repair only if the damage is shipment/  
transit-related.  
Keep the cap after installing the motherboard. ASUS will process Return Merchandise  
Authorization (RMA) requests only if the motherboard comes with the cap on the  
LGA1150 socket.  
The product warranty does not cover damage to the socket contacts resulting from  
incorrect CPU installation/removal, or misplacement/loss/incorrect removal of the PnP  
cap.  
2.3.1  
Installing the CPU  
To install the CPU:  
1. Locate the CPU socket on the motherboard.  
Before installing the CPU, ensure that the socket box is facing toward you and the load  
lever is on your right.  
2-9  
ASUS P9D-C Series  
 
2.  
Press the load lever with your thumb  
(A), then move it to the right (B) until it is  
released from the retention tab.  
Load lever  
Do not remove the PnP cap yet from  
the CPU socket. Doing so may bend  
the pins of the socket.  
Retention tab  
3.  
Lift the load lever until the load plate is  
completely lifted.  
Load plate  
4.  
Position the CPU above the socket,  
ensuring that the gold triangle mark is  
on the bottom-left corner of the socket,  
then fit the CPU notches to the socket's  
alignment keys.  
CPU notches  
The CPU fits in only one orientation.  
DO NOT force the CPU into the  
socket to prevent bending the pins on  
the socket and damaging the CPU.  
Gold  
triangle  
mark  
Alignment  
key  
Alignment  
key  
2-10  
Chapter 2: Hardware information  
5.  
Close the load plate (A), ensuring that  
the front edge of the load plate slides  
under the retention lock (B) then push  
down the load lever (C).  
Load lever  
Retention  
lock  
6.  
Insert the load lever under the retention tab to remove the PnP cap from the CPU  
socket.  
Load lever  
Retention tab  
7.  
Apply some Thermal Interface Material  
to the exposed area of the CPU that the  
heatsink will be in contact with, ensuring  
that it is evenly spread in a thin layer.  
Some heatsinks come with pre-  
applied Thermal Interface Material. If  
so, skip this step.  
The Thermal Interface Material is  
toxic and inedible. DO NOT eat it. If  
it gets into your eyes or touches your  
skin, wash it off immediately and seek  
professional medical help.  
2-11  
ASUS P9D-C Series  
2.3.2  
Installing the CPU heatsink  
The Intel® LGA1150 processor requires a specially designed CPU heatsink to ensure  
optimum thermal condition and performance.  
If you buy a CPU separately, ensure that you use only Intel® certified multi-directional  
CPU heatsink or CPU heatsink with CPU fan.  
Use an LGA1150-compatible CPU heatsink and CPU fan assembly only. The  
LGA1150 socket is incompatible with the LGA775 and LGA1366 sockets in size and  
dimension.  
If you purchased a separate CPU heatsink and fan assembly, ensure that the Thermal  
Interface Material is properly applied to the CPU heatsink or CPU before you install the  
heatsink and fan assembly.  
Ensure that you have installed the motherboard to the chassis before you install the CPU  
fan and heatsink assembly.  
A
To install the CPU heatsink and fan:  
B
1.  
Place the heatsink on top of the  
installed CPU, making sure that the  
four fasteners match the holes on the  
motherboard.  
B
A
2.  
Push down two fasteners at a time in  
a diagonal sequence to secure the  
heatsink and fan assembly in place.  
A
B
B
A
Orient the heatsink and fan assembly such that the CPU fan cable is closest to the CPU fan  
connector.  
2-12  
Chapter 2: Hardware information  
3.  
Connect the CPU fan cable to the connector on the motherboard labeled CPU_FAN1.  
DO NOT forget to connect the CPU fan connector! Hardware monitoring errors can occur if  
you fail to plug this connector.  
2.3.3  
Uninstalling the CPU heatsink and fan  
To uninstall the CPU heatsink and fan:  
1.  
Disconnect the CPU fan cable from the  
connector on the motherboard.  
A
B
2.  
3.  
Rotate each fastener counterclockwise.  
B
Pull up two fasteners at a time in a  
diagonal sequence to disengage the  
heatsink and fan assembly from the  
motherboard.  
A
A
B
B
A
4.  
Carefully remove the heatsink and fan assembly from the motherboard.  
2-13  
ASUS P9D-C Series  
2.3.4  
Installing the CPU heatsink in rack  
The Intel® 1150 processor requires a specially designed heatsink to ensure optimum thermal  
condition and performance.  
Ensure that you use qualified heatsink assembly only.  
Ensure that you have applied the thermal interface material to the top of the CPU  
before installing the heatsink and fan.  
1.  
Peel off the sticker on the heatsink metal  
plate and affix the plate to the back of  
the motherboard, matching the standoffs  
to the heatsink screw holes.  
2.  
Use a Phillips screwdriver to tighten  
the four heatsink screws using the  
recommended sequence below.  
A
C
D
A
C
B
D
B
1. Ensure that the heatsink is not skewed or tilted, otherwise the CPU will overheat.  
2. Do not overtighten the screws. Doing so can damage the CPU.  
2-14  
Chapter 2: Hardware information  
2.4  
System memory  
Overview  
2.4.1  
The motherboard comes with four Double Data Rate 3 (DDR3) Dual Inline Memory Modules  
(DIMM) sockets.  
A DDR3 module has the same physical dimensions as a DDR2 DIMM but is notched  
differently to prevent installation on a DDR2 DIMM socket. DDR3 modules are developed for  
better performance with less power consumption.  
The figure illustrates the location of the DDR3 DIMM sockets:  
2.4.2  
Memory Configurations  
You may install 2 GB, 4 GB, and 8 GB Unbuffered with ECC DDR3 DIMMs into the DIMM  
sockets using the memory configurations in this section.  
UDIMM  
DIMM Slot Per DIMM Populated  
DIMM Type  
Speed  
Rank per DIMM  
Channel  
per Channel  
2
2
1
2
Unbuffered DDR3  
Single Rank, Dual Rank  
Single Rank, Dual Rank  
1333/1600  
Unbuffered DDR3 1333/1600  
Always install DIMMs with the same CAS latency. For optimum compatibility, it is  
recommended that you obtain memory modules from the same vendor.  
Start installing the DIMMs in slots A2 and B2 (Blue).  
2-15  
ASUS P9D-C Series  
 
2.4.3  
Installing a DIMM on a single clip DIMM socket  
DIMM notch  
1.  
Unlock a DIMM socket by pressing the  
retaining clip outward.  
1
2.  
Align a DIMM on the socket such that  
the notch on the DIMM matches the  
DIMM slot key on the socket.  
2
DIMM slot key  
Unlocked retaining clip  
A DIMM is keyed with a notch so that it fits in only one direction. DO NOT force a DIMM into  
a socket in the wrong direction to avoid damaging the DIMM.  
3.  
Hold the DIMM by both of its ends  
then insert the DIMM vertically into the  
socket. Apply force to both ends of the  
3
DIMM simultaneously until the retaining  
clip snaps back into place and the  
DIMM cannot be pushed in any further  
to ensure proper sitting of the DIMM.  
Locked Retaining Clip  
Always insert the DIMM into the socket vertically to prevent DIMM notch damage.  
To install two or more DIMMs, refer to the user guide bundled in the motherboard  
package.  
Refer to the user guide for qualified vendor lists of the memory modules.  
Removing a DIMM from a single clip DIMM socket  
1.  
2.  
Press the retaining clip outward to  
unlock the DIMM.  
2
Remove the DIMM from the socket.  
1
Support the DIMM lightly with your fingers when pressing the retaining clips. The DIMM  
might get damaged when it flips out with extra force.  
2-16  
Chapter 2: Hardware information  
2.5  
Expansion slots  
In the future, you may need to install expansion cards. The following subsections describe the  
slots and the expansion cards that they support.  
Ensure to unplug the power cord before adding or removing expansion cards. Failure to do  
so may cause you physical injury and damage motherboard components.  
2.5.1  
Installing an expansion card  
To install an expansion card:  
1.  
Before installing the expansion card, read the documentation that came with it and  
make the necessary hardware settings for the card.  
2.  
3.  
Remove the system unit cover (if your motherboard is already installed in a chassis).  
Remove the bracket opposite the slot that you intend to use. Keep the screw for later  
use.  
4.  
Align the card connector with the slot and press firmly until the card is completely  
seated on the slot.  
5.  
6.  
Secure the card to the chassis with the screw you removed earlier.  
Replace the system cover.  
2.5.2  
Configuring an expansion card  
After installing the expansion card, configure it by adjusting the software settings.  
1.  
Turn on the system and change the necessary BIOS settings, if any. See Chapter 4 for  
information on BIOS setup.  
2.  
3.  
Assign an IRQ to the card. Refer to the tables on the next page.  
Install the software drivers for the expansion card.  
When using PCI cards on shared slots, ensure that the drivers support “Share IRQ” or that  
the cards do not need IRQ assignments. Otherwise, conflicts will arise between the two PCI  
groups, making the system unstable and the card inoperable.  
2-17  
ASUS P9D-C Series  
 
2.5.3  
Interrupt assignments  
Standard Interrupt assignments  
IRQ  
0
Priority Standard function  
1
System Timer  
1
2
Keyboard Controller  
2
-
Programmable Interrupt  
Communications Port (COM2)  
Communications Port (COM1)  
--  
3*  
11  
12  
13  
14  
15  
3
4*  
5*  
6
Floppy Disk Controller  
--  
7*  
8
System CMOS/Real Time Clock  
ACPI Mode when used  
IRQ Holder for PCI Steering  
IRQ Holder for PCI Steering  
PS/2 Compatible Mouse Port  
Numeric Data Processor  
Primary IDE Channel  
Secondary IDE Channel  
9*  
4
10*  
11*  
12*  
13  
14*  
15*  
5
6
7
8
9
10  
* These IRQs are usually available for ISA or PCI devices.  
2.5.4  
PCI Express x16 slots (x8 link)  
The onboard PCI Express x16 slots provide one x8 link that supports VGA cards and various  
server class high performance add-on cards.  
2.5.5  
PCI Express x8 slots (x4 link)  
The onboard PCI-E slot 5 provide one x4 Gen3 link to CPU1. This slot supports various  
server class high performance add-on cards.  
2.5.6  
PCI Express x1 slots (x1 link)  
The onboard PCI Express x1 slots provide one x1 link.  
2.5.7  
PCI slots  
The PCI slot supports cards such as a LAN card, USB card, and other cards that comply with  
PCI 2.3 specifications.  
2-18  
Chapter 2: Hardware information  
No.(Slot location) Short Description  
1 (slot 1)  
2 (slot 2)  
PCI1  
PCI2  
1 x PCI  
1 x PCI  
3 (slot 3)  
4 (slot 4)  
5 (slot 5)  
6 (slot 6)  
PCIE3 1 x PCI-E x1 (x1 Gen2 link)  
PCIE4 1 x PCI-E x1 (x1 Gen2 link)  
PCIE5 1 x PCI-E x8 (x4 Gen3 link)  
PCIE6 1 x PCI-E x16 (x8 Gen3 link)  
7 (slot 7)  
MIO1  
MIO-892 Supported  
additional slot 1  
1 x PIKE slot for Storage expansion (x4 Gen3 link)  
2.5.8  
PIKE slot  
The PIKE slots allows you to choose and change your preferred SAS solution easily. Install an  
optional ASUS PIKE RAID card based on your needs.  
2-19  
ASUS P9D-C Series  
2.5.9  
Installing the ASUS PIKE RAID card  
Follow the steps below to install an optional ASUS RAID card on your motherboard.  
1.  
Locate the PIKE RAID card slot on the  
motherboard.  
2.  
Align the golden fingers of the RAID card  
with the PIKE RAID card slot.  
3.  
Insert the RAID card into the PIKE RAID  
card slot. Ensure that it is completely  
seated on the PIKE RAID card slot.  
-
-
The motherboard illustration is for reference only. The motherboard layout and appearance  
may vary depending on the model, but the installation steps remain the same.  
Refer to section 2.8.2 Internal Connectors for the PIKE SAS/SATA connector  
location.  
2-20  
Chapter 2: Hardware information  
2.5.10  
Installing the Baseboard Management Card  
Follow the steps below to install an optional ASMB7 Management Card on your motherboard.  
1.  
Locate the Baseboard Management Card  
header on the motherboard.  
2.  
Orient and press the Management Card  
in place.  
The motherboard illustration is for reference only. The motherboard layout and appearance  
may vary depending on the model, but the installation steps remain the same.  
2-21  
ASUS P9D-C Series  
2.5.11  
Connecting the Thermal sensor cable  
Follow the steps below to connect the Thermal sensor (TR1) cable to the connector on your  
motherboard.  
1.  
Locate the Thermal Sensor (TR1)  
connector on the motherboard.  
2.  
Connect the Thermal Sensor cable to the  
connector.  
3.  
Place the other end of the Thermal Sensor cable to the device you would like to monitor  
temperature.  
The motherboard illustration is for reference only. The motherboard layout and appearance  
may vary depending on the model, but the installation steps remain the same.  
2-22  
Chapter 2: Hardware information  
2.6  
Onboard LEDs  
1.  
Standby Power LED (SB_PWR1)  
The motherboard comes with a standby power LED. The green LED lights up to  
indicate that the system is ON, in sleep mode, or in soft-off mode. This is a reminder  
that you should shut down the system and unplug the power cable before removing or  
plugging in any motherboard component. The illustration below shows the location of  
the onboard LED.  
2.  
Baseboard Management Controller LED (BMC_LED1)  
The green heartbeat LED blinks per second to indicate that the ASMB7 is working  
normally.  
The heartbeat LED functions only when you install the ASUS ASMB7.  
2-23  
ASUS P9D-C Series  
 
3.  
CPU Warning LED (ERR_CPU1)  
The CPU warning LEDs light up to indicate impending failure of the CPU.  
4.  
Power LED (+5V_LED1)  
This LED lights up when you turn on the system using the Power-on button.  
2-24  
Chapter 2: Hardware information  
5.  
Location LED (LOCLED1)  
This LED lights for you to conveniently locate the system in error.  
2-25  
ASUS P9D-C Series  
2.7  
Jumpers  
1.  
Clear RTC RAM (3-pin CLRTC1)  
This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can  
clear the CMOS memory of date, time, and system setup parameters by erasing  
the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in  
CMOS, which include system setup information such as system passwords.  
To erase the RTC RAM:  
1.  
2.  
Turn OFF the computer and unplug the power cord.  
Move the jumper cap from pins 1–2 (default) to pins 2–3. Keep the cap on pins  
2–3 for about 5–10 seconds, then move the cap back to pins 1–2.  
Plug the power cord and turn ON the computer.  
3.  
4.  
Hold down the <Del> key during the boot process and enter BIOS setup to re-  
enter data.  
Except when clearing the RTC RAM, never remove the cap on CLRTC jumper default  
position. Removing the cap will cause system boot failure!  
If the steps above do not help, remove the onboard battery and move the jumper again to  
clear the CMOS RTC RAM data. After the CMOS clearance, reinstall the battery.  
2-26  
Chapter 2: Hardware information  
 
2.  
VGA controller setting (3-pin VGA_SW1)  
This jumper allows you to enable or disable the onboard VGA controller. Set to pins  
1–2 to activate the VGA feature.  
3.  
LAN controller setting (3-pin LAN_SW1, LAN_SW2, LAN_SW3, LAN_SW4)  
These jumpers allow you to enable or disable the onboard Intel® I210AT Gigabit LAN  
controllers. Set to pins 1-2 to activate the Gigabit LAN feature.  
The jumpers LAN_SW3 and LAN_SW4 are available for P9D-C/4L only.  
2-27  
ASUS P9D-C Series  
4.  
RAID configuration utility selection (3-pin RAID_SEL1)  
This jumper allows you to select the RAID configuration utility to use when you create  
disk arrays. Place the jumper caps over pins 2–3 to use the Intel® Rapid Storage  
Technology.  
®
P9D-C/4L  
RAID_SEL1  
1
2
2
3
3ͬͩ Party  
(Default)  
Intel  
P9D-C Series RAID setting  
5.  
Platform Enviromental Control Interface Setting (3-pin PECI1)  
When an ASMB7-iKVM is installed, set these to pins 2-3 for correct sensor information  
of the Platform Environmental Control Interface (PECI). Set to pins 1-2 if ASMB7-iKVM  
is not installed.  
2-28  
Chapter 2: Hardware information  
2.8  
Connectors  
2.8.1  
Rear panel connectors  
1.  
2.  
3.  
4.  
PS/2 keyboard/mouse port (purple/green). This port is for a PS/2 keyboard or  
mouse.  
RJ-45 port for iKVM. This RJ-45 port functions only when you install ASMB7  
management card.  
Video Graphics Adapter port. This port is for a VGA monitor or other VGA-compatible  
devices.  
RJ-45 ports for LAN. These ports allows Gigabit connection to a Local Area  
Network (LAN) through a network hub. Refer to the table below for the LAN port LED  
indications.  
P9D-C/4L model has 4 LAN ports. P9D-C/2L model has 2 LAN ports. .  
5.  
6.  
Power-on Button. Press this button to turn on the system.  
Location LED. The Location LED is an onboard LED that ligths up when the Location  
Button on the front panel is pressed. This LED helps you visually locate the server among  
other servers especially when you are located at the back of the server rack.  
7.  
8.  
9.  
Power LED. This LED lights up when the Power-on button is pressed and the system  
is on.  
USB 2.0 ports 1 and 2. These two 4-pin Universal Serial Bus (USB) ports are  
available for connecting USB 2.0 devices.  
USB 3.0 ports 1 and 2. These two 4-pin USB ports are available for connecting USB  
3.0 devices.  
LAN port LED indications  
ACT/LINK SPEED  
Activity/Link LED  
Description  
Speed LED  
LED  
LED  
Status  
Status  
Description  
OFF  
No link  
OFF  
10 Mbps connection  
100 Mbps connection  
1 Gbps connection  
GREEN  
Linked  
ORANGE  
GREEN  
LAN port  
BLINKING  
Data activity  
2-29  
ASUS P9D-C Series  
 
2.8.2  
Internal connectors  
1.  
Serial ATA 6.0/3.0 Gbps connectors  
(7-pin 6Gbps SATA1, SATA2, SATA3, SATA4 [Light Blue])  
(7-pin 3Gbps SATA5, SATA6 [Black])  
Supported by the Intel® C224 chipset, these connectors are for the SerialATAsignal cables  
for Serial ATA hard disk drives that allows up to 6Gbps of data transfer rate.  
If you installed Serial ATA hard disk drives, you can create a RAID 0, RAID 1, RAID 10,  
or RAID 5 configuration.  
The actual data transfer rate depends on the speed of Serial ATA hard disks installed.  
2-30  
Chapter 2: Hardware information  
2.  
PSAS connectors (7-pin PSAS1, PSAS2, PSAS3, PSAS4, PSAS5, PSAS6, PSAS7,  
PSAS8 [Blue])  
This motherboard comes with eight (8) PIKE Serial Attached SCSI (PSAS) connectors  
that supports both Serial Attached SCSI (SAS) and Serial ATA (SATA). Each connector  
supports one device.  
These connectors function only when you install a PIKE RAID card.  
Connect the SAS hard disk drives to PSAS connectors 1–4 (blue) when installing a  
4-port PIKE RAID card.  
2-31  
ASUS P9D-C Series  
3.  
USB 2.0 connector (10-1 pin USB78; A-Type USB9)  
These connectors are for USB 2.0 ports. Connect the USB module cables to connectors  
USB78. These USB connectors comply with USB 2.0 specification that supports up to  
480 Mbps connection speed.  
4.  
USB 3.0 connector (20-1 pin USB3_34)  
These connectors allow you to connect a USB 3.0 module for additional USB 3.0 front  
or rear panel ports. With an installed USB 3.0 module, you can enjoy all the benefits of  
USB 3.0 including faster data transfer speeds of up to 5Gbps, faster charging time for  
USB-chargeable devices, optimized power efficiency, and backward compatibility with  
USB 2.0.  
2-32  
Chapter 2: Hardware information  
5.  
Thermal sensor cable connectors (3-pin TR1)  
This connector allows you to connect a Thermal sensor cable that is used for temperature  
monitoring. Connect the Thermal sensor cable to the connector and place its probe to the  
device that you want to check the temperature.  
6.  
CPU, front, and rear fan connectors  
(4-pin CPU_FAN1, FRNT_FAN1, FRNT_FAN2, FRNT_FAN3, REAR_FAN1)  
The fan connectors support cooling fans. Connect the fan cables to the fan connectors  
on the motherboard, ensuring that the black wire of each cable matches the ground pin  
of the connector.  
DO NOT forget to connect the fan cables to the fan connectors. Insufficient air flow  
inside the system may damage the motherboard components.  
These are not jumpers! DO NOT place jumper caps on the fan connectors!  
All fans feature the ASUS Smart Fan technology.  
2-33  
ASUS P9D-C Series  
7.  
Serial General Purpose Input/Output connector (6-1 pin SGPIO1)  
The SGPIO 1 connectors are used for the Intel Rapid Storage Technology Enterprise  
SGPIO interface that controls the LED pattern generation, device information, and  
general purpose data.  
The PSGPIO 1 and PSGPIO 2 connectors only functions when you install an ASUS PIKE  
RAID card.  
2-34  
Chapter 2: Hardware information  
8.  
LAN34_LED connector (5-1 pin LAN34_LED1)  
These leads are for Gigabit LAN activity LEDs on the front panel. Connect the LAN LED  
cable to the backplane for LAN activity indication.  
The connector LAN34_LED1 is available for P9D-C/4L only.  
9.  
Parallel port connector (26-1 pin LPT1)  
This connector is for a parallel port. Connect the parallel port module cable to this  
connector, then install the module to a slot opening at the back of the system chassis.  
2-35  
ASUS P9D-C Series  
10. Serial port connectors (10-1 pin COM1/COM2)  
These connectors are for the serial COM ports. Connect the serial port module cable  
to one of these connectors, then install the module to a slot opening at the back of the  
system chassis.  
11. Power Supply SMBus connector (5-pin PSUSMB1)  
This connector allows you to connect SMBus (System Management Bus) to the power  
supply unit to read PSU information. Devices communicate with an SMBus host and/or  
other SMBus devices using the SMBus interface.  
This connector functions only when you install the ASUS ASMB7.  
2-36  
Chapter 2: Hardware information  
12. Trusted Platform Module connector (20-1 pin TPM1)  
This connector supports a Trusted Platform Module (TPM) system, which can securely  
store keys, digital certificates, passwords, and data. A TPM system also helps enhance  
network security, protects digital identities, and ensures platform integrity.  
13. SATA DOM power connector (4-pin PWR3)  
This 4-pin connector is for 5V power of a certain SATA DOM (Disk on Module) device  
when using an appropriate cable.  
The SATA DOM power connector is for output power only. It has a maximum output  
current of 1A.  
Ensure that the power of the SATA DOM device that you will use is less than 1A.  
2-37  
ASUS P9D-C Series  
14. ATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1)  
These connectors are for the ATX power supply plugs. The power supply plugs are  
designed to fit these connectors in only one orientation. Find the proper orientation and  
push down firmly until the connectors completely fit.  
DO NOT forget to connect the 24-pin and the 8-pin power plugs; otherwise, the system  
will not boot up.  
Use of a power supply unit (PSU) with a higher power output is recommended when  
configuring a system with more power-consuming devices. The system may become  
unstable or may not boot up if the power is inadequate.  
This motherboard supports ATX2.0 PSU or later version.  
Ensure that your PSU can provide at least the minimum power required by your  
system.  
2-38  
Chapter 2: Hardware information  
15. System panel connector (20-1 pin PANEL1)  
This connector supports several chassis-mounted functions.  
1. System power LED (3-pin PLED)  
This 3-pin connector is for the system power LED. Connect the chassis power  
LED cable to this connector. The system power LED lights up when you turn on  
the system power, and blinks when the system is in sleep mode.  
2. Message LED (2-pin MLED)  
This 2-pin connector is for the message LED cable that connects to the front  
message LED. The message LED is controlled by Hardware monitor to indicate  
an abnormal event occurance.  
3. System warning speaker (4-pin SPEAKER)  
This 4-pin connector is for the chassis-mounted system warning speaker. The  
speaker allows you to hear system beeps and warnings.  
4. Hard disk drive activity LED (2-pin +HDLED)  
This 2-pin connector is for the HDD Activity LED. Connect the HDD Activity LED  
cable to this connector. The IDE LED lights up or flashes when data is read from  
or written to the HDD.  
5. Power button/soft-off button (2-pin PWRSW)  
This connector is for the system power button. Pressing the power button turns  
the system on or puts the system in sleep or soft-off mode depending on the BIOS  
settings. Pressing the power switch for more than four seconds while the system  
is ON turns the system OFF.  
6. Reset button (2-pin RESET)  
This 2-pin connector is for the chassis-mounted reset button for system reboot  
without turning off the system power.  
2-39  
ASUS P9D-C Series  
16. Auxiliary panel connector (20-2 pin AUX_PANEL1)  
This connector is for additional front panel features including front panel SMB, locator  
LED and switch, chassis intrusion, and LAN LEDs.  
1. Front panel SMB (6-1 pin FPSMB)  
These leads connect the front panel SMBus cable.  
2. LAN activity LED (2-pin LAN1_LINKACTLED, LAN2_LINKACTLED)  
These leads are for Gigabit LAN activity LEDs on the front panel.  
3. Chassis intrusion (4-1 pin CASEOPEN)  
These leads are for the intrusion detection feature for chassis with intrusion  
sensor or microswitch. When you remove any chassis component, the sensor  
triggers and sends a high-level signal to these leads to record a chassis intrusion  
event. The default setting is short CASEOPEN and GND pin by jumper cap to  
disable the function.  
4. Locator LED (2-pin LOCATORLED1, LOCATORLED2)  
These leads are for the locator LED1 and LED2 on the front panel. Connect the  
Locator LED cables to these 2-pin connector. The LEDs will light up when the  
Locator button is pressed.  
5. Locator Button/Switch (2-pin LOCATORBTN#)  
These leads are for the locator button on the front panel. This button queries the  
state of the system locator.  
2-40  
Chapter 2: Hardware information  
17. VGA connector (16-1 pin VGA_HDR1)  
This connector supports the VGA High Dynamic-Range interface.  
18. Hard disk activity LED connector (4-pin HDLED1)  
This LED connector is for the storage add-on card cable connected to the SATA or SAS  
add-on card. The read or write activities of any device connected to the SATA or SAS  
add-on card causes the front panel LED to light up.  
2-41  
ASUS P9D-C Series  
2-42  
Chapter 2: Hardware information  
Chapter 3:  
Powering Up  
3
Chapter summary  
This chapter describes the power up sequence, and ways of shutting down the  
system.This chapter contains the following sections:  
ASUS P9D-C Series  
3.1  
Starting up for the first time  
1.  
2.  
3.  
4.  
5.  
After making all the connections, replace the system case cover.  
Be sure that all switches are off.  
Connect the power cord to the power connector at the back of the system chassis.  
Connect the power cord to a power outlet that is equipped with a surge protector.  
Turn on the devices in the following order:  
a. Monitor  
b. External storage devices (starting with the last device on the chain)  
c. System power  
6.  
After applying power, the system power LED on the system front panel case lights up.  
For systems with ATX power supplies, the system LED lights up when you press the  
ATX power button. If your monitor complies with “green” standards or if it has a “power  
standby” feature, the monitor LED may light up or switch between orange and green  
after the system LED turns on.  
The system then runs the power-on self-test or POST. While the tests are running, the  
BIOS beeps or additional messages appear on the screen. If you do not see anything  
within 30 seconds from the time you turned on the power, the system may have failed  
a power-on test. Check the jumper settings and connections or call your retailer for  
assistance.  
7.  
At power on, hold down the <Del> key to enter the BIOS Setup. Follow the instructions  
in Chapter 4.  
3-3  
ASUS P9D-C Series  
 
3.2  
Powering off the computer  
3.2.1  
Using the OS shut down function  
Using Windows® Server 2008 R2:  
1.  
2.  
Click the Start button, move the cursor to the triangle on the right of Log off, then click  
Shut Down.  
From the Shutdown Event Tracker, select the option that best describes why you want  
to shut down the computer.  
3.  
4.  
5.  
Ensure that the Planned check box is checked.  
If necessary, key in comments.  
Click OK.  
Using Windows® Server 2012:  
1.  
2.  
3.  
4.  
Press <Ctrl+Alt+Del>.  
Click on the Power icon on the lower right side of the screen.  
Select Shut down.  
In the Shutdown Event Tracker, select the Other (Planned) option in the selection  
lists. Otherwise, select the option that best describes why you want to shut down the  
computer.  
5.  
Click Continue.  
3.2.2  
Using the dual function power switch  
While the system is ON, press the power switch for less than four seconds to put the system  
to sleep mode or to soft-off mode, depending on the BIOS setting.  
Pressing the power switch for more than four seconds lets the system enter the soft-off mode  
regardless of the BIOS setting.  
3-4  
Chapter 3: Powering up  
 
Chapter 4:  
BIOS setup  
4.1  
Managing and updating your BIOS  
The following utilities allow you to manage and update the motherboard Basic Input/Output  
System (BIOS) setup:  
1.  
ASUS CrashFree BIOS 3  
To recover the BIOS using a bootable USB flash disk drive when the BIOS file fails or  
gets corrupted.  
2.  
3.  
ASUS EzFlash  
Updates the BIOS using a USB flash disk.  
BUPDATER  
Updates the BIOS in DOS mode using a bootable USB flash disk drive.  
Refer to the corresponding sections for details on these utilities.  
Save a copy of the original motherboard BIOS file to a bootable USB flash disk drive in  
case you need to restore the BIOS in the future. Copy the original motherboard BIOS using  
the BUPDATER utility.  
4.1.1  
ASUS CrashFree BIOS 3 utility  
The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS file  
when it fails or gets corrupted during the updating process. You can update a corrupted BIOS  
file using a USB flash drive that contains the updated BIOS file.  
Prepare a USB flash drive containing the updated motherboard BIOS before using this  
utility.  
Recovering the BIOS from a USB flash drive  
To recover the BIOS from a USB flash drive:  
1.  
Insert the USB flash drive with the original or updated BIOS file to one USB port on the  
system.  
2.  
The utility will automatically recover the BIOS. It resets the system when the BIOS  
recovery finished.  
DO NOT shut down or reset the system while recovering the BIOS! Doing so would cause  
system boot failure!  
The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the  
ASUS website at www.asus.com to download the latest BIOS file.  
4-3  
ASUS P9D-C Series  
 
4.1.2  
ASUS EzFlash Utility  
The ASUS EzFlash Utility feature allows you to update the BIOS using a USB flash disk  
without having to use a DOS-based utility.  
Download the latest BIOS from the ASUS website at www.asus.com before using this utility.  
The succeeding BIOS screens are for reference only. The actual BIOS screen displays may  
not be the same as shown.  
To update the BIOS using EzFlash Utility:  
1.  
Insert the USB flash disk that contains the latest BIOS file to the USB port.  
2.  
Enter the BIOS setup program. Go to the Tool menu to select ASUS EzFlash Utility and  
press <Enter> to enable it.  
ASUS Tek. EzFlash Utility  
New Platform  
Platform : P9D-C/4L  
Version : 0077  
Current Platform  
Platform : P9D-C/4L  
Version : 0060  
Build Date :01/31/2013  
Build Date :12/03/2013  
FS0  
System Volume Information  
<DIR>  
<DIR>  
<DIR>  
P9D-C/4L Bios  
P9D-C/4L Bios  
Windows  
[Up/Down/Left/Right]:Switch [Enter]:Choose [q]:Exit  
3.  
Press <Tab> to switch to the Drive field.  
4.  
Press the Up/Down arrow keys to find the USB flash disk that contains the latest BIOS  
then press <Enter>.  
5.  
Press <Tab> to switch to the Folder Info field.  
6.  
Press the Up/Down arrow keys to find the BIOS file then press <Enter>.  
7.  
Reboot the system when the update process is done.  
This function can support devices such as a USB flash disk with FAT 32/16 format and  
single partition only.  
DO NOT shut down or reset the system while updating the BIOS to prevent system boot  
failure!  
4-4  
Chapter 4: BIOS setup  
Ensure to load the BIOS default settings to ensure system compatibility and stability. Press  
<F5> and select Yes to load the BIOS default settings.  
4.1.3  
BUPDATER utility  
The succeeding BIOS screens are for reference only. The actual BIOS screen displays may  
not be the same as shown.  
The BUPDATER utility allows you to update the BIOS file in DOS environment using a  
bootable USB flash disk drive with the updated BIOS file.  
Updating the BIOS file  
To update the BIOS file using the BUPDATER utility:  
1.  
2.  
3.  
Visit the ASUS website at www.asus.com and download the latest BIOS file for the  
motherboard. Save the BIOS file to a bootable USB flash disk drive.  
Download the BUPDATER utility (BUPDATER.exe) from the ASUS support website at  
support.asus.com to the bootable USB flash disk drive you created earlier.  
Boot the system in DOS mode, then at the prompt, type:  
BUPDATER /i[filename].CAP  
where [filename] is the latest or the original BIOS file on the bootable USB flash disk  
drive, then press <Enter>.  
A:\>BUPDATER /i[file name]CAP  
4-5  
ASUS P9D-C Series  
The utility verifies the file, then starts updating the BIOS file.  
ASUSTek BIOS Update for DOS V1.06 (09/08/04)  
FLASH TYPE: MXIC 25L1605A  
Current ROM  
Update ROM  
BOARD: P9D-C/4L  
BOARD: P9D-C/4L  
VER: 0202  
VER: 0201  
DATE: 12/01/2013  
DATE: 12/09/2013  
PATH:  
WARNING! Do not turn off power during flash BIOS  
Note  
Writing BIOS:  
DO NOT shut down or reset the system while updating the BIOS to prevent system boot  
failure!  
The utility returns to the DOS prompt after the BIOS update process is completed.  
Reboot the system from the hard disk drive.  
4.  
The BIOS update is finished! Please restart your system.  
C:\>  
4-6  
Chapter 4: BIOS setup  
4.2  
BIOS setup program  
This motherboard supports a programmable firmware chip that you can update using the  
provided utility described in section 4.1 Managing and updating your BIOS.  
Use the BIOS Setup program when you are installing a motherboard, reconfiguring your  
system, or prompted to “Run Setup.” This section explains how to configure your system  
using this utility.  
Even if you are not prompted to use the Setup program, you can change the configuration of  
your computer in the future. For example, you can enable the security password feature or  
change the power management settings. This requires you to reconfigure your system using  
the BIOS Setup program so that the computer can recognize these changes and record them  
in the CMOS RAM of the firmware chip.  
The firmware chip on the motherboard stores the Setup utility. When you start up the  
computer, the system provides you with the opportunity to run this program. Press <Del>  
during the Power-On Self-Test (POST) to enter the Setup utility; otherwise, POST continues  
with its test routines.  
If you wish to enter Setup after POST, restart the system by pressing <Ctrl>+<Alt>+<Del>,  
or by pressing the reset button on the system chassis. You can also restart by turning the  
system off then back on. Do this last option only if the first two failed.  
The Setup program is designed to make it as easy to use as possible. Being a menu-driven  
program, it lets you scroll through the various sub-menus and make your selections from the  
available options using the navigation keys.  
The default BIOS settings for this motherboard apply for most conditions to ensure  
optimum performance. If the system becomes unstable after changing any BIOS  
settings, load the default settings to ensure system compatibility and stability. Press  
<F5> and select Yes to load the BIOS default settings.  
The BIOS setup screens shown in this section are for reference purposes only, and  
may not exactly match what you see on your screen.  
Visit the ASUS website (www.asus.com) to download the latest BIOS file for this  
motherboard.  
4-7  
ASUS P9D-C Series  
 
4.2.1  
Menu items  
Main  
BIOS menu screen  
Menu bar  
Configuration fields  
General help  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced Event Logs Boot Monitor Security Tool Exit  
BIOS Information  
BIOS Vendor  
BIOS Version  
Compliancy  
BIOS Version  
Build Date  
Set the Date, Use Tab to  
switch between Data elements.  
American Megatrends  
4.6.5.4  
UEFI 2.3.1; PI 1.2  
0077 x64  
01/31/2013  
System Date  
System Time  
[Mon 02/21/2013]  
[10:10:10]  
Select Screen  
Select Item  
→←:  
↑↓:  
Enter: Select Item  
+/-: Change Opt.  
F1: General Help  
F2: Previous Values  
F5: Optimized Defaults  
F10: Save & Exit  
ESC: Exit  
Version 2.15.1236. Copyright (C) 2013 American Megatrends, Inc.  
Navigation keys  
4.2.2  
Menu bar  
The menu bar on top of the screen has the following main items:  
Main For changing the basic system configuration  
Advanced For changing the advanced system settings  
Event Logs  
Boot  
For changing the event log settings  
For changing the system boot configuration  
Monitor  
For displaying the system temperature, power status, and changing  
the fan settings  
Security  
Tool  
For changing the security settings  
For configuring options for special functions  
For selecting the exit options  
Exit  
To select an item on the menu bar, press the right or left arrow key on the keyboard until the  
desired item is highlighted.  
4-8  
Chapter 4: BIOS setup  
4.2.3  
Menu items  
The highlighted item on the menu bar displays the specific items for that menu. For example,  
selecting Main shows the Main menu items. The other items (Advanced, Event Logs, Boot,  
Monitor, Security, Tool, and Exit) on the menu bar have their respective menu items.  
4.2.4  
Submenu items  
A solid triangle before each item on any menu screen means that the item has a submenu. To  
display the submenu, select the item and press <Enter>.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Main Advanced Event Logs Boot Monitor Security Tool Exit  
PCI, PCI-X and PCI Express  
Settings.  
PCI Subsystem Settings  
ACPI Settings  
Trusted Computing  
4.2.5  
Navigation keys  
At the bottom right corner of a menu screen are the navigation keys for the BIOS setup  
program. Use the navigation keys to select items in the menu and change the settings.  
4.2.6  
General help  
At the top right corner of the menu screen is a brief description of the selected item.  
4.2.7  
Configuration fields  
These fields show the values for the menu items. If an item is user-configurable, you can  
change the value of the field opposite the item. You cannot select an item that is not user-  
configurable. A configurable field is enclosed in brackets, and is highlighted when selected. To  
change the value of a field, select it and press <Enter> to display a list of options.  
4.2.8  
Pop-up window  
Select a menu item and press <Enter> to display a pop-up window with the configuration  
options for that item.  
4.2.9  
Scroll bar  
A scroll bar appears on the right side of a menu screen when there are items that do not fit on  
the screen. Press the Up/Down arrow keys or <Page Up> /<Page Down> keys to display the  
other items on the screen.  
4-9  
ASUS P9D-C Series  
4.3  
Main menu  
When you enter the BIOS Setup program, the Main menu screen appears. The Main menu  
provides you an overview of the basic system information, and allows you to set the system  
date and time.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced Event Logs Boot Monitor Security Tool Exit  
Main  
BIOS InformationBIOS Vendor  
BIOS Version  
American Megatrends  
4.6.5.4  
Set the Date, Use Tab to  
switch between Data  
elements.  
Compliancy  
UEFI 2.3.1; PI 1.2  
0077 x64  
BIOS Version  
Build Date  
01/31/2013  
System Date  
System Time  
[Mon 02/22/2013]  
[10:10:10]  
4.3.1  
System Date  
Allows you to set the system date to [Day mm/dd/yyyy].  
Where:  
Day = Day of the week  
mm = month (numeric value)  
dd = day (numeric value)  
yyyy = year (numeric value)  
4.3.2  
System Time  
Allows you to set the system time to [hh/mm/ss].  
Where:  
hh = hour (numeric value)  
mm = minutes (numeric value)  
ss = seconds (numeric value)  
4-10  
Chapter 4: BIOS setup  
 
4.4  
Advanced menu  
The Advanced menu items allow you to change the settings for the CPU and other system  
devices.  
Take caution when changing the settings of the Advanced menu items. Incorrect field values  
can cause the system to malfunction.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Main Advanced Event Logs Boot Monitor Security Tool Exit  
CPUConguration
P
C
I
,
P
C
I
-X
a
n
d
PC
I
E
x
p
r
e
s
s
Settings.  
PCH-IO Configuration  
SATA Configuration  
Systems Agent (SA) Configuration  
PCI Subsystem Settings  
USB Configuration  
TPM  
ACPI Settings  
WHEA Configuration  
NCT6779D Super IO Configuration  
Intel Server Platform Services  
Onboard LAN Configuration  
MIO Card Configuration  
Serial Port Console Redirection  
Runtime Error Logging  
APM  
Network Stack  
Intel RC Drivers Version Detail  
4-11  
ASUS P9D-C Series  
 
4.4.1  
CPU Configuration  
The items in this menu show the CPU-related information that the BIOS automatically detects.  
Some items may not appear if your CPU does not support the related functions.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Enabled for WIndows XP and  
Linux (OS optimized for  
CPU Configuration  
Hyper-Threading Technology)  
Genuine Intel (R) CPU 0000 @ 2.50GHz  
and Disabled for other OS  
CPU Signature  
Microcode Patch  
Max CPU Speed  
Min CPU Speed  
CPU Speed  
306c2  
(OS not optimized for Hyper-  
ffff0006  
2500 MHz  
800 MHz  
Threading Technology).  
When Disabled only one  
thread per enabled core is  
2500 MHz  
4
enabled.  
Processor Cores  
Intel HT Technology  
Intel VT-x Technology  
Intel SMX Technology  
64-bit  
EIST Technology  
CPU C3 State  
CPU C6 State  
CPU C7 State  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
L1 Data Cache  
L1 Code Cache  
L2 Cache  
32 kB x 4  
32 kB x 4  
256 kB x 4  
8192 kB  
→←: Select Screen  
↑↓: Select Item  
Enter: Select Item  
+/-: Change Opt.  
L3 Cache  
Version 2.15.1236. Copyright (C) 2013 American Megatrends, Inc.  
Navigate to the second page of the screen to see the rest of items in this menu by pressing  
the Up or Down arrow keys.  
To quickly go to the last item of the second page, press the Page Down button. Press the  
Page Up button to go back to the first item in the first page.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
L2 Cache  
L3 Cache  
Hyper-threading  
Active Processor Cores  
Execute Disable Bit  
Inter Virtualization Technology[Enabled]  
256 kB x 4  
8192 kB  
→←: Select Screen  
↑↓: Select Item  
Enter: Select Item  
[Enabled]  
+/-: Change Opt.  
[All]  
F1: General Help  
[Enabled]  
F2: Previous Values  
F5: Optimized Defaults  
F10: Save & Exit  
Hardware Prefetcher  
Adjacent Cache Line Prefetch  
CPU AES  
[Enabled]  
[Enabled]  
[Enabled]  
[Turbo Performance]  
[Enabled]  
[Enabled]  
[Performance]  
[Enabled]  
[Enabled]  
[Enabled]  
[Enabled]  
[CPU C7s]  
[Enabled]  
[Enabled]  
[AUTO]  
ESC: Exit  
Boot performance mode  
EIST  
Turbo Mode  
Energy Performance  
CPU C states  
Enhanced C1 state  
CPU C3 Report  
CPU C6 report  
CPU C7 report  
C1 state auto demotion  
C3 state auto demotion  
Package C State limit  
LakeTiny Feature  
Intel TXT (LT) Support  
ACPI T State  
[Disabled]  
[Disabled]  
[Disabled]  
Version 2.15.1236. Copyright (C) 2013 American Megatrends, Inc.  
4-12  
Chapter 4: BIOS setup  
Hyper-threading [Enabled]  
Allows you to enable or disable the Intel Hyper-Threading Technology function.  
Configuration options: [Enabled] [Disabled]  
Active Processor Cores [All]  
Allows you to choose the number of CPU cores to activate in each processor package.  
Configuration options: [All] [1] [2] [3]  
Execute Disable Bit [Enabled]  
Allows you to enable or disable the XD feature that can prevent certain classes of malicious  
buffer overflow attacks when combined with a supporting OS. Configuration options:  
�Enabled�Disabled�  
Intel Virtualization Technology [Enabled]  
Allows you to utilize the additional hardware capabilities provided by Vanderpool Technology.  
Configuration options: [Enabled] [Disabled]  
Hardware Prefetcher [Enabled]  
Allows you to enable or disable the Mid Level Cache (L2) streamer. Configuration options:  
�Enabled�Disabled�  
Adjacent Cache Line Prefetch [Enabled]  
Allows you to enable or disable the Mid Level Cache (L2) prefetching of adjacent cache lines.  
Configuration options: [Enabled] [Disabled]  
CPU AES [Enabled]  
Allows you to enable or disable the CPU Advance Encryption Standard instructions.  
Configuration options: [Disabled] [Enabled]  
Boot performance mode [Turbo Performance]  
This item allows you to select the performance state that the BIOS will set before OS handoff.  
Configuration options: [Max Non-Turbo Performace] [Max Battery] [Turbo Performance]  
EIST [Enabled]  
Allows you to enable or disable the Enhanced Intel SpeedStep Technology (EIST).  
Configuration options: [Enabled] [Disabled]  
Turbo Mode [Enabled]  
This item appears only when you set the EIST item to �Enabled. This allows you to enable or  
disable the Intel® Turbo Mode Technology.  
Configuration options: [Enabled] [Disabled]  
Energy Performance [Performance]  
Allows you to optimize between performance and power savings. Configuration options:  
[Performance] [Balanced Performance] [Balanced Energy] [Energy Efficient]  
4-13  
ASUS P9D-C Series  
CPU C states [Enabled]  
Allows you to enable or disable the CPU C states. Configuration options: [Enabled] [Disabled]  
This following items appears only when you set the CPU C states to �Enabled.  
Enhanced C1 State [Enabled]  
This item allows you to enable or disable the Enhanced C1 state. Configuration options:  
�Enabled�Disabled�  
CPU C3 Report [Enabled]  
Allows you to enable or disable the CPU C3 report to OS. Configuration options:  
�Enabled�Disabled�  
CPU C6 Report [Enabled]  
Allows you to enable or disable the CPU C6 report to OS. Configuration options:  
�Disabled�Enabled�  
CPU C7 Report [CPU C7s]  
Allows you to enable or disable the CPU C7 report to OS. Configuration options:  
�Disabled�CPU C7�CPU C7s�  
C1 state auto demotion [Enabled]  
Allows you to enable or disable the demotion of the C3/C6/C7 request to C1 based on  
uncore auto-demote information. Configuration options: �Disabled�Enabled�  
C3 state auto demotion [Enabled]  
Allows you to enable or disable the demotion of the C6/C7 request to C3 based on  
uncore auto-demote information. Configuration options: �Disabled�Enabled�  
Package C State limit [AUTO]  
Allows you set the Package C State limit to AUTO. Configuration options: [C2] [C3] [C6] [C7]  
�C7s�AUTO�  
LakeTiny Feature [Disabled]  
Allows you enable or disable LakeTiny for C state configuration. Configuration options:  
�Disabled�Enabled�  
Intel TXT (LT) Suppot [Disabled]  
Allows you to enable or disable the Intel TXT (LT) support. Configuration options: [Disabled]  
�Enabled�  
ACPI T State [Disabled]  
Allows you to enable or disable the ACPI T state. Configuration options: [Disabled] [Enabled]  
4-14  
Chapter 4: BIOS setup  
4.4.2  
PCH-IO Configuration  
Allows you to configure PCH parameters.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
USB Configuration  
settings.  
Intel PCH RC Version  
Intel PCH SKU Name  
Intel PCH Rev ID  
1.0.0.0  
C224  
04/C1  
USB Configuration  
PCH Azalia Configuration  
USB Configuration  
Allows you to set the USB Configuration settings.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
USB Configuration  
Mode of operation of xHCI  
controller.  
XHCI Mode  
[Auto]  
EHCI1  
EHCI2  
[Enabled]  
[Enabled]  
USB Ports Per-Port Disable Control [Disabled]  
XHCI Mode [Auto]  
Allows you to set the mode of operation of the xHCI controller. Configuration options: [Auto]  
�Enabled�Disabled�  
EHCI1 / EHCI2 [Enabled]  
Allows you to control the USB EHCI (USB 2.0) functions. One EHCI controller must always  
be enabled. Configuration options: [Auto] [Disabled] [Enabled]  
USB Ports Per-Port Disable Control [Disabled]  
Allows you to control the disabling of the USB ports (0-13). Configuration options:  
�Auto�Disabled�Enabled�  
USB Port #0-#13 Disable [Enabled]  
This items only appears when you set the USB Ports Per-Port Disable Control to �Enabled�  
This item allows you to control the disabling of each of the USB ports (0-13). Configuration  
options: �Disabled�Enabled�  
4-15  
ASUS P9D-C Series  
PCH Azalia Configuration  
Allows you to control the detection of the Azalia device. Configuration options:  
�Auto�Disabled�  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
PCH Azalia Configuration  
Control Detection of  
the Azalia device.  
Azalia  
[Auto]  
Disabled = Azalia will be  
unconditionally disabled  
Enabled = Azalia will be  
unconditionally Enabled  
Auto = Azalia will be  
enabled if present,  
disabled otherwise.  
4.4.3  
SATA Configuration  
While entering Setup, the BIOS automatically detects the presence of SATA devices. The  
SATA Port items show Not Present if no SATA device is installed to the corresponding SATA  
port.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Enable or disable SATA  
Device.  
SATA Controller(s)  
SATA Mode Selection  
S.M.A.R.T. Status Check  
[Enabled]  
[AHCI]  
[Enabled]  
Serial ATA Port 0  
Software Preserve  
Port 0  
HardDisk (250.0GB)  
SUPPORTED  
[Enabled]  
Hot Plug  
[Enabled]  
SATA Device Type  
Spin Up Device  
Serial ATA Port 1  
Software Preserve  
Port 1  
[Hard Disk Drive]  
[Disabled]  
HardDisk (250.0GB)  
SUPPORTED  
[Enabled]  
[Enabled]  
Hot Plug  
SATA Device Type  
Spin Up Device  
Serial ATA Port 2  
Software Preserve  
Port 2  
[Hard Disk Driver]  
[Disabled]  
HardDisk (250.0GB)  
SUPPORTED  
[Enabled]  
[Enabled]  
Hot Plug  
SATA Device Type  
Spin Up Device  
[Hard Disk Driver]  
[Disabled]  
SATA Controller(s) [Enabled]  
This allows you to enable or disable the SATA Device. Configuration options: [Enabled]  
�Disabled�  
SATA Mode Selection [AHCI]  
This allows you to choose how SATA controller(s) should operate. Configuration options:  
�AHCI�IDE�RAID�  
S.M.A.R.T. Status Check [Enabled]  
Self-Monitoring, Analysis, and Reporting Technology (S.M.A.R.T.) is a monitor system. When  
read/write of your hard disk errors occur, this feature allows the hard disk to report warning  
messages during the POST. Configuration options: [Enabled] [Disabled]  
4-16  
Chapter 4: BIOS setup  
Compatible Mode [Disabled]  
This item only appears when you set the SATA Mode Selection to �IDE. This item allows you  
to enable or disable the Compatible mode. Configuration options: [Disabled] [Enabled]  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Determines how SATA  
controller(s) operate.  
SATA Controller(s)  
SATA Mode Selection  
Compatible Mode  
[Enabled]  
[IDE]  
[Disabled]  
[Enabled]  
S.M.A.R.T. Status Check  
Serial SATA Port 0  
Software Preserve  
Serial SATA Port 1  
Software Preserve  
Serial SATA Port 2  
Software Preserve  
Serial SATA Port 3  
Software Preserve  
Serial SATA Port 4  
Software Preserve  
Serial SATA Port 5  
Software Preserve  
HardDisk (250.0GB)  
SUPPORTED  
HardDisk (250.0GB)  
SUPPORTED  
HardDisk (250.0GB)  
SUPPORTED  
HardDisk (250.0GB)  
SUPPORTED  
HardDisk (250.0GB)  
SUPPORTED  
ASUS DVD-E8 ATAPI  
SUPPORTED  
4.4.4  
System Agent (SA) Configuration  
This allows you to change System Agent parameters.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Check to enable VT-d  
function on MCH.  
System Agent Bridge Name  
System Agent RC Version  
VT-d Capability  
Haswell  
1.0.0.0  
Supported  
VT-d  
[Enabled]  
[Disabled]  
[Disabled]  
[Offboard]  
Enable NB Card  
BDAT ACPI Table Support  
VGA Priority  
Memory Configuration  
VT-d [Enabled]  
This allows you enable or disable the VT-d function on MCH. Configuration options: [Enabled]  
�Disabled�  
Enable NB CRID [Disabled]  
This allows you enable or disable the NB CRID WorkAround. Configuration options: [Enabled]  
�Disabled�  
BDAT ACPI Table Support [Disabled]  
This allows you enable or disable the support for the BDAT ACPI table. Configuration options:  
�Enabled�Disabled�  
VGA Priority [Offboard]  
This allows you to prioritize between the onboard and offboard video device to be found.  
Configuration options: [Onboard] [Offboard]  
4-17  
ASUS P9D-C Series  
Memory Configuration  
This allows you to change memory information settings.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Maximum Memory Frequency  
Selections in MHz.  
Memory Information  
Memory RC Version  
Memory Frequency  
Usage Memory  
DIMM_A1  
1.0.0.0  
1067 MHz  
1024 MB (DDR3)  
Not Present  
1024 MB (DDR3)  
Not Present  
Not Present  
7
DIMM_A2  
DIMM_A3  
DIMM_A4  
CAS Latency (tCL)  
Minimum delay time  
CAS to RAS (tRCDmin)  
7
Row Precharge (tRPmin)  
7
Active to Precharge (tRASmin)  
20  
Memory Frequency Limiter  
ECC Support  
[Auto]  
[Enabled]  
[Enabled]  
[Enabled]  
[Disabled]  
Memory Scrambler  
Memory Remap  
GDXC Support  
Memory Frequency Limiter [Auto]  
This allows you to set the memory frequency in MHz. Configuration options: [Auto] [1333]  
�1600�  
ECC Support [Enabled]  
This allows you to enable or disable the DDR ECC support. Configuration options: [Enabled]  
�Disabled�  
Memory Scrambler [Enabled]  
This allows you to enable or disable the Memory Scrambler support. Configuration options:  
�Enabled�Disabled�  
Memory Remap [Enabled]  
This allows you to enable or disable the Memory Remap above 4G. Configuration options:  
�Enabled�Disabled�  
GDXC Support [Disabled]  
This allows you to enable or disable the GDXC feature. Configuration options: [Enabled]  
�Disabled�  
4-18  
Chapter 4: BIOS setup  
4.4.5  
PCI Subsystem Settings  
Allows you to configure PCI, PCI-X, and PCI Express Settings.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Change PCI Express  
Devices Settings.  
PCI Bus Driver Version  
V 2.05.02  
[Disabled]  
[Enabled]  
PCI 64bit Resources Handling  
Above 4G Decoding  
PCI Common Settings  
Load RT32 Image  
PCI Express Settings  
PCIE Slot Configuration  
Above 4G Decoding [Disabled]  
This item allows you to enable or disable 64-bit capable devices to be decoded in above  
4G Address Space if your system supports 64-bit PCI decoding. Configuration Options:  
�Disabled�Enabled�  
Load RT32 Image [Enabled]  
Allows you to enable or disable the RT32 Image Loading. Configuration Options:  
�Disabled�Enabled�  
PCI Express Settings  
Allows you to change the settings of the PCI Express Devices.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Set the ASPM Level: Force  
L0s  
PCI Express Device Register Setting  
PCI Express Device Register Settings  
ASPM Support  
WARNING: Enabling ASPM may cause some  
PCIE devices to fail  
- Force all links to L0s  
State  
[Disabled]  
: AUTO - BIOS auto  
configure :DISABLE -  
Disables ASM  
ASPM Support [Disabled]  
This item allows you to enable or disable support to Active State Power Management (ASPM).  
ASPM is a power management protocol that is used to extend battey life. Configuration  
options:  
�Disabled�  
[Auto]  
�Force L0s�  
Disables ASMP  
BIOS auto configure  
Force all links to L0s State  
4-19  
ASUS P9D-C Series  
PCIE Slot Configuration  
Allows you to perform PCIE slot configurations.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Enabled/Disabled PCIE3  
Option Rom  
PCIE Slot Configuration  
PCIE3  
Not Present  
[Enabled]  
PCIE3 Option Rom  
PCIE4  
Not Present  
[Enabled]  
PCIE4 Option Rom  
PCIE5  
Not Present  
[Enabled]  
PCIE5 Option Rom  
PCIE6  
Not Present  
[Enabled]  
PCIE6 Option Rom  
PIKE  
Not Present  
[Enabled]  
PIKE Option Rom  
PCIE Option Rom 3 - 6 [Enabled]  
Allows you to enable or disable the PCIE slots. Configuration Options: [Disabled][Enabled]  
PIKE Option Rom [Enabled]  
Allows you to enable or disable the PIKE Option Rom. Configuration Options:  
�Disabled�Enabled�  
4-20  
Chapter 4: BIOS setup  
4.4.6  
USB Configuration  
This allows you to make changes on the configuration settings of the USB.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
USB Configuration  
Enables Legacy USB  
support. AUTO option  
disables legacy  
support if no USB  
devices are connected.  
DISABLE option will  
keep USB devices  
available only for  
EFI applications.  
USB Devices  
1 mouse,2 Hubs  
Legacy USB Support  
USB3.0 Support  
XHCI Hand-off  
EHCI Hand-off  
USB Mass Storage Driver Support  
Port 60/64 Emulation  
[Enabled]  
[Enabled]  
[Enabled]  
[Disabled]  
[Enabled]  
[Enabled]  
USB hardware delays and time-outs:  
USB transfer time-out  
[20 sec]  
[20 sec]  
[Auto]  
Device reset time-out  
Device power-up delay  
The USB Devices item shows the auto-detected values. If no USB device is detected, the  
item shows None.  
Legacy USB Support [Enabled]  
Allows you to enable or disable the support for legacy USB devices. Setting to �Autoallows  
the system to detect the presence of USB devices at startup. If detected, the USB controller  
legacy mode is enabled. If no USB device is detected, the legacy USB support is disabled.  
Configuration options: [Disabled] [Enabled] [Auto]  
USB3.0 Support [Enabled]  
Enables or disables the USB3.0 (XHCI) controller support. Configuration options: [Disabled]  
�Enabled�  
XHCI Hand-off [Enabled]  
This functions as a workaround for OSes without XHCI hand-off support. Configuration  
options: �Disabled�Enabled�  
EHCI Hand-off [Enabled]  
This functions as a workaround for OSes without EHCI hand-off support. Configuration  
options: �Disabled�Enabled�  
USB Mass Storage Driver Support [Enabled]  
This allows you to enable or disable the USB Mass Storage driver support. Configuration  
options: �Disabled�Enabled�  
Port 60/64 Emulation [Enabled]  
This allows you to enable the I/O port 60h/64h emulation support. This should be enabled for  
the complete USB keyboard legacy support for non-USB aware OSes. Configuration options:  
�Disabled�Enabled�  
4-21  
ASUS P9D-C Series  
USB transfer time-out [20 sec]  
Allows you to select the USB transfer time-out value. Configuration options:  
�1 sec�5 sec�10 sec�20 sec�  
Device reset time-out [20 sec]  
Allows you to select the USB device reset time-out value. Configuration options:  
�10 sec�20 sec�30 sec�40 sec�  
Device power-up delay [Auto]  
This allows you to set the maximum time the device will take before it properly reports itself to  
the Host Controller. Configuration options: [Auto] [Manual]  
4.4.7  
TPM  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Configuration  
TPM Support  
Enables or Disables BIOS  
support for security  
device.O.S. will not  
show Security Device. TCG  
EFI protocol and INT1A  
interface will not be  
available.  
[Disable]  
Current Status Information  
NO Security Device Found  
Security Device Support [Disabled]  
Allows you to enable or disable BIOS support for security devices. Configuration options:  
�Disabled�Enabled�  
4.4.8  
ACPI Settings  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
ACPI Settings  
Enables or Disables  
System ability to  
Hibernate (OS/S4 Sleep  
State). This option may  
not be effective with  
some OS.  
Enable Hibernation  
ACPI Sleep State  
[Enabled]  
[Both S1 and S3 avai...]  
Enable Hibernation [Enabled]  
Allows you to enable or disable the Hibernation feature (OS/S4 sleep state).  
Configuration options: [Disabled] [Enabled]  
ACPI Sleep State [Both S1 and S3 available for OS to choose from]  
Allows you to set the ACPI Sleep state. Configuration options: [Suspend Disabled]  
�S1 only (CPU Stop Clock)�S3 only (Suspend to RAM)�  
�Both S1 and S3 available for OS to choose from�  
4-22  
Chapter 4: BIOS setup  
4.4.9  
WHEA Support  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Enables or disable  
Windows Hardware Error  
Architecture.  
WHEA Support  
[Enabled]  
WHEA [Enabled]  
Allows you to enable or disable the Windows® Hardware Error Architecture (WHEA) support.  
Configuration options: [Disabled] [Enabled]  
4.4.10  
NCT6779D Super IO Configuration  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
NCT6779D Super IO Configuration  
Set Parameters of  
Serial Port 1 (COM1)  
Serial Port 1 Configuration  
Serial Port 2 Configuration  
Parallel Port Configuration  
Serial Port 1/2 Configuration  
The sub-items in this menu allows you to set the parameters of the Serial Port 1 (COM1) and  
the Serial Port 2 (COM2).  
Serial Port [Enabled]  
Allows you to enable or disable the serial port (COM 1/2). Configuration options: [Enabled]  
�Disabled�  
Change Settings [Auto]  
This item only appears when you set the Serial Port to �Enabled. This item allows you to  
select the serial port base address. Configuration options:  
�Auto�  
[IO=3F8h; IRQ=4]  
�IO=3F8h: IRQ=3, 4, 5, 6, 7, 10, 11, 12�  
[IO=2F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12]  
[IO=3E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12]  
[IO=2E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12]  
[IO=2E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12]  
4-23  
ASUS P9D-C Series  
Parallel Port Configuration  
The sub-items in this menu allow you to set the parallel port configuration.  
Parallel Port [Enabled]  
Allows you to enable or disable the parallel port (LPT/LPTE). Configuration options:  
�Enabled�Disabled�  
Change Settings [Auto]  
Allows you to select the optimal setting for the super IO device.  
Configuration options: [Auto] [IO=378h; IRQ=5] [IO=378h: IRQ=5, 6, 7, 10, 11, 12]  
[IO=278h; IRQ=5, 6, 7, 10, 11, 12] [IO=3BCh; IRQ=5, 6, 7, 10, 11, 12]  
Device Mode [STD Printer Mode]  
Allows you to select the printer port mode. Configuration options: [STD Printer mode]  
�SPP Mode�EPP-1.9 and SPP Mode�EPP-1.7 and SPP Mode�  
�ECP Mode�ECP and EPP 1.9 Mode�ECP and EPP 1.7 Mode�  
4.4.11  
IntelServer Platform Services  
This item displays the information of the Intel Server Platform Services configured in the  
system.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Intel Sever Platform Services Configuration  
ME BIOS Interface Ver :  
1.0  
SPS Version  
3.0.4.162  
ME FW Status Value  
ME FW State  
:
:
0xf0345  
SPS ME FW Active  
M0 without UMA  
No Error  
ME FW Operation State :  
ME FW Error Code  
ME NM FW Status Value :  
:
0x80000001  
Power Optimized Mode  
0
BIOS Booting Mode  
Cores Disabled  
:
:
ME FW SKU Information :  
End-of-POST Status  
Node Manager  
EOP disabled in POST  
:
4-24  
Chapter 4: BIOS setup  
4.4.12  
Onboard LAN Configuration  
This allows you to change the enable or disable the onboard LAN.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Onboard LAN Configuration  
INTEL I210 LAN  
Disable/Enable  
INTEL I210 LAN1 MAC:  
INTEL I210 LAN2 MAC:  
INTEL I210 LAN3 MAC:  
INTEL I210 LAN4 MAC:  
00:E0:18:10:18:E8  
00:E0:18:10:18:E9  
00:E0:18:10:18:EA  
00:E0:18:10:18:EB  
INTEL I210 LAN1 Enable  
INTEL I210 LAN1 OpROM  
INTEL I210 LAN2 Enable  
INTEL I210 LAN2 OpROM  
INTEL I210 LAN3 Enable  
INTEL I210 LAN3 OpROM  
INTEL I210 LAN4 Enable  
INTEL I210 LAN4 OpROM  
[Enabled]  
[PXE]  
[Enabled]  
[PXE]  
[Enabled]  
[Disabled]  
[Enabled]  
[Disabled]  
INTEL I210 LAN1 - LAN4 Enable [Enabled]  
Allows you to enable or disable the INTEL I210 LAN function in the system. Configuration  
Options: �Enabled�Disabled�  
INTEL I210 LAN1/LAN2 OpROM [PXE], INTEL I210 LAN3/LAN4 OpROM  
[Disabled]  
Allows you to launch the Intel I210 LAN OpROM. Configuration options: [Disabled] [PXE]  
�iSCSI�  
P9D-C/4L model has 4 LAN ports. P9D-C/2L model has 2 LAN ports. .  
4.4.13  
MIO Card Configuration  
This item allows you to set MIO Card configuration settings.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Set MIO Card  
MIO Card Type  
Front Panel Type  
MIO Card Type  
[ALC 892]  
[AC97]  
Front Panel Type [AC97]  
Allows you to select the front Panel type of the MIO. Configuration options:  
�AC97�HD�  
4-25  
ASUS P9D-C Series  
4.4.14  
Serial Port Console Redirection  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Console Redirection  
Enable or Disable.  
COM1  
Console Redirection  
[Disabled]  
[Enabled]  
Console Redirection Settings  
COM2  
Console Redirection  
Console Redirection Settings  
Serial Port for Out-of-Band Management/  
Windows Emergency Management Services (EMS)  
Console Redirection  
Console Redirection Settings  
[Disabled]  
COM1/COM2 Console Redirection [Disabled/Enabled]  
Allows you to enable or disable the console redirection feature. Configuration options:  
�Disabled�Enabled�  
The Console Redirection Settings becomes configurable when Console Redirection is  
set to �Enabled.  
COM1/COM2 Console Redirection Settings  
The settings specify how the host computer and the remote computer (which the user is  
using) will exchange data. Both computers should have the same or compatible settings.  
Terminal Type [VT-UTF8]  
Allows you to set the terminal type.  
�VT100�  
�VT100+�  
�VT-UTF8�  
�ANSI�  
ASCII char set.  
Extends VT100 to support color, function keys, among others  
Uses UTF8 encoding to map Unicode chars onto 1 or more bytes  
Extended ASCII char set  
Bits per second [57600]  
Selects serial port transmission speed. The speed must be matched on the other side. Long  
or noisy lines may require lower speeds. Configuration options: [9600] [19200] [38400]  
�57600�115200�  
Data Bits [8]  
Allows you to set the data bits. Configuration options: [7] [8]  
Parity [None]  
Allows you to select the parity bit. A parity bit is sent with the data bits to detect transmission  
errors. Configuration options: [None] [Even] [Odd] [Mark] [Space]  
Stop Bits [1]  
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.) The  
standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop  
bit. Configuration options: [1] [2]  
4-26  
Chapter 4: BIOS setup  
Flow Control [Hardware RTS/CTS]  
Flow control can prevent data loss from buffer overflow. When sending data, if the receiving  
buffers are full, a “stop” signal can be sent to stop the data flow. Once the buffers are empty,  
a “start” signal can be sent to re-start the flow. Hardware flow control uses two wires to send  
start/stop signals. Configuration options: [None] [Hardware RTS/CTS]  
VT -UTF8 Combo Key Support [Enabled]  
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100 terminals.  
Configuration options: [Disabled] [Enabled]  
Recorder Mode [Disabled]  
This allows you to enable or disable the Recorded mode to capture Terminal data.  
Configuration options: [Disabled] [Enabled]  
Resolution 100x31 [Enabled]  
This allows you to enable or disable the extended terminal resolution. Configuration options:  
�Disabled�Enabled�  
Legacy OS Redirection Resolution [80x24]  
This allows you to set the number of rows and columns supported on the Legacy OS.  
Configuration options: [80x24] [80x25]  
Putty Keypad [VT100]  
This allows you to select the FunctionKey and Keypad on Putty. Configuration options:  
�VT100�LINUX�XTERMR6�SCO�ESCN�VT400�  
Redirection After BIOS POST [Bootloader]  
This setting allows you to specify if Bootloader is selected than Legacy console redirection.  
Configuration options: [Always Enable] [Bootloader]  
4-27  
ASUS P9D-C Series  
Serial Port for Out-of-Band Management/Windows Emergency Management  
Services (EMS) Settings  
The following items only appears when you set the Console Redirection to �Enabled.  
Out-of-Band Mgmt Port [COM1]  
Allows remote management of a Windows Server OS through a serial port. Configuration  
options: �COM1�COM2�  
Terminal Type [VT-UTF8]  
Allows you to set the terminal type for out-of-band management. Configuration options:  
�VT100�  
�VT100+�  
�VT-UTF8�  
�ANSI�  
ASCII char set.  
Extends VT100 to support color, function keys, et.  
Uses UTF8 encoding to map Unicode chars onto 1 or more bytes  
Extended ASCII char set  
Bits per second [115200]  
Selects serial port transmission speed. The speed must be matched on the other side. Long  
or noisy lines may require lower speeds. Configuration options: [9600] [19200] [38400]  
�57600�115200�  
Flow Control [None]  
Allows you to set the flow control to prevent data loss from buffer overflow. Configuration  
options: �None�Hardware RTS/CTS�Software Xon/Xoff�  
4-28  
Chapter 4: BIOS setup  
4.4.15  
Runtime Error Logging Support  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Enable/Disable  
Runtime Error Logging  
Support.  
Runtime Error Logging Support  
[Disabled]  
Runtime Error Logging Support [Disabled]  
Allows you to enable or disable the Runtime Error Logging Support. Configuration options:  
�Disabled�Enabled�  
4.4.16  
APM  
Allows you to configure the Advance Power Management (APM) settings.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Restore AC Power Loss  
Power On By PCI  
[Last State]  
[Disabled]  
[Disabled]  
[Disabled]  
Specify what state  
to go to when power  
is re-applied after  
a power failure (G3  
state).  
Power On By PCIE  
Power On By RTC  
EuP Ready  
[Disabled]  
Restore AC Power Loss [Last State]  
Allows you to set the state the system will go to after an AC power loss. Configuration  
options: �Power Off�Power On�Last State�  
Power On By PCI [Disabled]  
You can use this option to enable or disable the Wake-on-LAN feature of the Intel® LAN.  
Configuration options: [Disabled] [Enabled]  
Power On By PCIE [Disabled]  
This allows you to enable or diasble the PCIE devices to generate a wake event.  
Configuration options: [Disabled] [Enabled]  
Power On By RTC [Disabled]  
This item allows you to enable or disable RTC to generate a wake event. When set to  
�Enabled, the items RTC Alarm Date (Days) and Hour/Minute/Second becomes user-  
configurable where you can set values.  
EUP Ready [Disabled]  
This item allows you to switch off some power at S5 to get the system ready for EuP  
requirement. Configuration options: [Enabled] [Disabled]  
4-29  
ASUS P9D-C Series  
4.4.17  
Network Stack  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Enable/Disable the  
network stack (Pxe  
and UEFI)  
Network stack  
[Disable]  
Network stack [Disable]  
Enables or disables the network stack feature. Configuration options: [Disable] [Enable]  
4.4.18  
Intel RC Drivers Version Detail  
This item displays the Version String for the Intel RC Drivers.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Advanced  
Intel CPU RC Version  
Memory RC Version  
Intel SA RC Version  
Intel PCH RC Version  
1.0.0.0  
1.0.0.0  
1.0.0.0  
1.0.0.0  
4-30  
Chapter 4: BIOS setup  
4.5  
Event Logs menu  
The Event Logs menu items allow you to change the event log settings and view the system  
event logs.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Main Advanced Boot Monitor Security Tool Exit  
Event Logs  
Change Smbios Event Log Settings  
View Smbios Event Log  
View System Event Log  
Press <Enter> to change  
the Smbios Event Log  
configuration.  
Change Smbios Event Log Settings  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Main Advanced Event Logs Boot Monitor Security Tool Exit  
Event Logs  
Enabling/Disabling Options  
Smbios Event Log  
Change this to enable or  
disable all features of  
Smbios Event Logging during  
boot.  
[Enabled]  
Erasing Settings  
Erase Event Log  
When Log is Full  
[No]  
[Do Nothing]  
NOTE: All values changed here do not take effect  
until computer is restarted.  
Smbios Event Log [Enabled]  
Allows you to enable or disable all features of Smbios event logging during boot.  
Configuration options: [Disabled] [Enabled]  
Erase Event Log [No]  
This item only appears when Smbios Event Log is set to �Enabled. This item allows you to  
select the options for erasing Smbios event log. Configuration options: [No] [Yes, Next reset]  
Yes, Every reset�  
When Log is Full [Do Nothing]  
This item only appears when Smbios Event Log is set to �Enabled. This item allows you to  
select the options for reaction when the event logs are full. Configuration options:  
�Do Nothing�Erase Immediately�  
4-31  
ASUS P9D-C Series  
 
4.6  
Boot menu  
The items in Boot menu allows you to change the options on how the system will boot.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Main Advanced Event Logs Monitor Security Tool Exit  
Boot  
Boot Configuration  
Number of seconds to wait  
for setup activation key.  
65535(0xFFFF) means  
Setup Prompt Timeout  
Bootup NumLock State  
1
[On]  
indefinite waiting.  
Full Screen Logo  
[Enabled]  
07.69  
CSM16 Module Version  
GateA20 Active  
[Upon Request]  
[Force BIOS]  
[Immediate]  
Option ROM Messages  
INT19 Trap Response  
Boot Device Seeking  
[Endless PXE]  
Boot Option Priorities  
Boot Option #1  
[P0: DVD  
]
Boot Option #2  
[P4: Harddisk 2.50G]  
[Windows Boot Man..]  
Boot Option #3  
Network Device BBS Priorities  
Hard Drive BBS Priorities  
CSM parameters  
Setup Prompt Timeout [xx]  
This item allows you to adjust the number of seconds to wait for setup activation key. Use the  
<+> and <-> keys to specify the values.  
Bootup NumLock State [On]  
Allows you to select the power-on state for the NumLock. Configuration options: [Off] [On]  
Full Screen Logo [Enabled]  
Allows you to enable or disable the full screen logo display feature. Configuration options:  
.
�Disabled�Enabled�  
Set the Full Screen Logo to �Enabledto use the ASUS MyLogo2™ feature.  
GateA20 Active [Upon Request]  
This item is useful when any RT code is execute above 1MB. When set to �Upon Request,  
the GA20 can be disabled using BIOS services. When set to �Always, disabling of GA20 is  
.
not allowed. Configuration options: [Upon Request] [Always]  
Option ROM Messages [Force BIOS]  
Allows you to set the display mode for Option ROM. Configuration options:  
�Force BIOS�Keep Current�  
4-32  
Chapter 4: BIOS setup  
 
INT19 Trap Response [Immediate]  
This item allows you to set the BIOS reaction on INT19 trapping by Option ROM.  
Configuration options: [Immediate] [Postponed]  
Boot Device Seeking [Endless PXE]  
This allows you to enable the Boot Device Seeking option. Configuration options:  
�Endless PXEContinuosly seek remote boot image until boot image is found or  
the operation is aborted <Ctrl>+<Alt>+<Del> is pressed by the  
user).  
�Normal�  
Seek remote boot image once then stop.  
Boot Option Priorities  
These items specify the boot device priority sequence from the available devices. The number  
of device items that appears on the screen depends on the number of devices installed in the  
system.  
To select the boot device during system startup, press <F8> when ASUS Logo  
appears.  
To access Windows® OS in Safe Mode, do any of the following:  
- Press <F5> when ASUS Logo appears.  
- Press <F8> after POST.  
Network Device BBS Priorities / Hard Drive BBS Priorities  
This allows you to set the order of the legacy devices in this group.  
4-33  
ASUS P9D-C Series  
CSM Parameters  
This allows you to set OpROM execution, boot options filter, and other OpROM settings  
settings.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Boot  
Launch CSM  
[Enabled]  
This option controls if  
CSM will be launched.  
Boot Option filter  
[Legacy only]  
[Legacy only]  
[Legacy only]  
[Legacy only]  
Launch PXE OpROM policy  
Launch Storage OpRom policy  
Launch Video OpRom policy  
Other PCI device ROM priority  
[Legacy OpROM]  
Launch CSM [Enabled]  
This option allows you to enable or disable the launch of CSM. Configuration options:  
�Disabled�Enabled�  
Boot Option filter [Legacy only]  
This option allows you to control what devices the system can boot to. Configuration options:  
�UEFI and Legacy�Legacy only�UEFI only�  
Launch PXE OpROM policy [Legacy only]  
This option allows you to control the execution of UEFI and Legacy PXE OpROM.  
Configuration options: [Do not launch] [UEFI only] [Legacy only] [Legacy first] [UEFI first]  
Launch Storage OpROM policy [Legacy only]  
This option allows you to control the execution of UEFI and Legacy Storage OpROM.  
Configuration options: [Do not launch] [UEFI only] [Legacy only] [Legacy first] [UEFI first]  
Launch Video OpROM policy [Legacy only]  
This option allows you to control the execution of UEFI and Legacy Storage OpROM.  
Configuration options: [Do not launch] [UEFI only] [Legacy only] [Legacy first] [UEFI first]  
Other PCI device ROM priority [Legacy OpROM]  
This option allows you to control the execution of UEFI and Legacy Storage OpROM.  
Configuration options: [UEFI OpROM] �Legacy OpROM�  
4-34  
Chapter 4: BIOS setup  
4.7  
Monitor menu  
The Monitor menu displays the system temperature/power status, and allows you to change  
the fan settings.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Main Advanced Event Logs Boot Monitor Security Tool Exit  
Monitor  
CPU Temperature  
MB Temperature  
TR1 Temperature  
CPU_FAN1 Speed  
REAR_FAN1 Speed  
FRNT_FAN1 Speed  
FRNT_FAN2 Speed  
FRNT_FAN3 Speed  
VCORE1  
: +58ºC/ +162ºF  
: +52ºC/ +151ºF  
: N/A  
Whisper/Generic/High/  
Speed/Full Speed  
: 1054 RPM  
: N/A  
: N/A  
: N/A  
: N/A  
: +1.800 V  
: +12.288 V  
: +5.040 V  
: +1.504 V  
: +3.408 V  
: +1.296 V  
: +3.344 V  
+12V  
+5V  
+VDDQ  
+3VSB  
+3.3V  
VBAT  
FAN Speed Control  
[Generic Mode]  
CPU/MB/TR1 Temperature [xxx�C/xxx�F]  
The onboard hardware monitor automatically detects and displays the CPU and motherboard  
component temperatures.  
CPU_FAN1 Speed; FRNT_FAN1–3 Speed; REAR_FAN1 Speed [xxxx RPM] or  
[Ignore] / [N/A]  
The onboard hardware monitor automatically detects and displays the speed of CPU fans,  
front fans, and rear fan in rotations per minute (RPM). If the fan is not connected to the  
motherboard, the field shows N/A.  
VCORE1 Voltage: +12V, +5V, +VDDQ, +3VSB, +3.3V, and VBAT  
The onboard hardware monitor automatically detects the voltage output through the onboard  
voltage regulators.  
Fan Speed Control [Generic Mode]  
Allows you to configure the ASUS Smart Fan feature that smartly adjusts the fan speeds for  
more efficient system operation. Configuration options:  
�Low Speed Mode�Generic Mode�High Speed Mode�Full Speed Mode�  
4-35  
ASUS P9D-C Series  
 
4.8  
Security  
This menu allows a new password to be created or a current password to be cchanged. The  
menu also enables or disables the Secure Boot state and lets the user configure the System  
Mode state.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Security  
Main Advanced Event Logs Boot Monitor Tool Exit  
Password Description  
Set Setup Administrator  
Password  
If ONLY the Administrator’s password is set, then  
this only limits access to Setup and is only asked  
for when entering Setup.  
If ONLY the User’s password is set, then this  
is a power on password and must be entered to  
boot or enter Setup. In Setup the User will have  
Administrator rights.  
The password length must be  
in the following range:  
Minimum length  
Maximum length  
3
20  
Administrator Password  
User Password  
Clear Password  
System Boot Menu  
HDD Security Configuration:  
P1: HardDisk  
P2: HardDisk  
Administrator Password  
To set an administrator password:  
1.  
2.  
3.  
Select the Administrator Password item and press <Enter>.  
From the Create New Password box, key in a password, then press <Enter>.  
Confirm the password when prompted.  
To change an administrator password:  
1.  
2.  
Select the Administrator Password item and press <Enter>.  
From the Enter Current Password box, key in the current password, then press  
<Enter>.  
3.  
From the Create New Password box, key in a new password, then press <Enter>.  
4.  
Confirm the password when prompted.  
To clear the administrator password, follow the same steps as in changing an administrator  
password, but press <Enter> when prompted to create/confirm the password.  
4-36  
Chapter 4: BIOS setup  
 
User Password  
To set a user password:  
1.  
2.  
3.  
Select the User Password item and press <Enter>.  
From the Create New Password box, key in a password, then press <Enter>.  
Confirm the password when prompted.  
To change a user password:  
1.  
2.  
Select the User Password item and press <Enter>.  
From the Enter Current Password box, key in the current password, then press  
<Enter>.  
3.  
From the Create New Password box, key in a new password, then press <Enter>.  
4.  
Confirm the password when prompted.  
To clear a user password:  
1.  
2.  
Select the Clear User Password item and press <Enter>.  
Select Yes from the Warning message window then press <Enter>.  
Secure Boot Menu  
This item allows you to customize the Secure Boot settings.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Security  
Platform Mode  
Secure Boot  
Setup  
Secure Boot flow control.  
Secure Boot can be  
Disabled  
enabled only when  
Secure Boot Control  
[Enabled]  
Platform Key (PK) is  
enrolled and Platform is  
operating in User mode.  
Secure Boot Mode  
Image Execution Policy  
Key Management  
[Standard]  
Secure Boot Control [Enabled]  
This item allows you to enable or disable the Secure Boot flow control. Configuration options:  
�Disabled�Enabled�  
Secure Boot Mode [Standard]  
This item allows you to select the mode of the Secure boot to change Execution policy and  
Secure Boot Key management. Configuration options: [Standard] [Custom]  
4-37  
ASUS P9D-C Series  
Image Execution Policy  
This item only appears when you set the Secure Boot Mode to �Custom. This allows you to  
manage the Image Policy on Security Violation.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Security  
Image Execution Policy  
per device path on  
Security Violation.  
Interval FV  
Option ROM  
Removable Media  
Fixed Media  
[Always Execute]  
[Deny Execute]  
[Deny Execute]  
[Deny Execute]  
Internal FV [Always Execute]  
Configuration options: [Always Execute]  
Option ROM/Removable Media/Fixed Media [Deny Execute]  
Configuration options: [Always Execute] [Always Deny] [Allow Execute] [Defer Execute]  
�Deny Execute�Query User�  
Key Management  
This item only appears when you set the Secure Boot Mode to �Custom. This allows you to  
modify Secure Boot variables and set Key Management page.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Security  
Factory Default Key Provisioning [Disabled]  
Install All Factory Default Keys  
Install Factory default  
Secure Boot Keys when  
System is in Setup Mode  
Platform Key (PK)  
Set new PK  
Delete PK  
NOT INSTALLED  
Key Exchange Key Database (KEK)  
Set new KEK  
NOT INSTALLED  
NOT INSTALLED  
NOT INSTALLED  
Delete KEK  
Append Var to KEK  
Authorized Signature Database (DB)  
Set new DB  
Delete DB  
Append Var to DB  
Forbidden Signature Database (DBX)  
Set new DBX  
Delete DBX  
Append Var to DBX  
Factory Default Key Provisioning [Disabled]  
Configuration options: [Disabled] [Enabled]  
Install All Factory Default Keys  
This item will ask you if you want to Install Factory Default secure variables. Select Yes if you  
want to load the default secure variables, otherwise select No.  
Platform Key (PK)/Key Exchange Key Database (KEK)/Authorized Signature Database  
(DB)/ Forbidden Signature Database (DBX)  
Configuration options: [Set New] [Delete] [Append]  
4-38  
Chapter 4: BIOS setup  
4.9  
Tool menu  
The Tool menu items allow you to configure options for special functions. Select an item then  
press <Enter> to display the submenu.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Main Advanced Event Logs Boot Monitor Security Tool Exit  
Tool  
Press ENTER to run the  
utility to select and  
update BIOS.  
Start EzFlash  
Start EzFlash utility  
Allows you to run the Start EzFlash utility. For more information, see section  
4.1.2 ASUS EzFlash utility.  
4.10  
Exit menu  
The Exit menu items allow you to save or discard your changes to the BIOS items.  
Aptio Setup Utility - Copyright (C) 2013 American Megatrends, Inc.  
Main Advanced Event Logs Boot Monitor Security Tool  
Exit  
Exit system setup without  
saving any changes.  
Discard Changes & Exit  
Save Changes & Reset  
Discard Changes & Reset  
Restore Defaults  
Boot Override  
IBA GE Slot 0B00 v1404  
IBA GE Slot 0B00 v1404  
Windows Boot Manager  
Launch EFI Shell from filesystem device  
Pressing <Esc> does not immediately exit this menu. Select one of the options from this  
menu or <F10> from the legend bar to exit.  
Discard Changes & Exit  
This option allows you to exit the Setup program without saving your changes. When you  
select this option or if you press <Esc>, a confirmation window appears. Select Yes to discard  
changes and exit.  
Save Changes & Reset  
Once you are finished making your selections, choose this option from the Exit menu to  
ensure the values you selected are saved. When you select this option or if you press <F10>,  
a confirmation window appears. Select Yes to save changes and exit.  
4-39  
ASUS P9D-C Series  
 
Discard Changes & Reset  
This option allows you to reset without saving your changes. When you select this option or  
if you press <ENTER>, a confirmation window appears. Select Yes to discard changes and  
reset.  
Restore Defaults  
This option allows you restore or load the default values for all the setup options. When you  
select this option or if you press <ENTER>, a confirmation window appears. Select Yes to  
apply the default values or press <Esc> to exit.  
Launch EFI Shell from filesystem device  
This option allows you to launch the EFI Shell application (shellx64.efi) from one of the  
available filesystem devices. Select Yes to proceed, or No to cancel, and then press <Enter>.  
4-40  
Chapter 4: BIOS setup  
Chapter 5:  
RAID Configuration  
5
Chapter summary  
This chapter provides instructions for setting up, creating, and configuring RAID sets using  
the available utilities.  
This chapter contains the following sections:  
Intel® Rapid Storage Technology enterprise SATA Option ROM Utility 5-5  
Intel® Rapid Storage Technology enterprise (Windows) ......................5-13  
ASUS P9D-C Series  
5.1  
Setting up RAID  
The motherboard comes with the Intel® C224 controller that supports the following SATA  
RAID solutions:  
Intel® Rapid Storage Technology enterprise Option ROM Utility with RAID 0,  
RAID 1, RAID 10, and RAID 5 support (for Windows® OS only).  
5.1.1  
RAID definitions  
RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in  
parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a  
sustained data transfer rate, double that of a single disk alone, thus improving data access  
and storage. Use of two new identical hard disk drives is required for this setup.  
RAID 1 (Data mirroring) copies and maintains an identical image of data from one drive to a  
second drive. If one drive fails, the disk array management software directs all applications  
to the surviving drive as it contains a complete copy of the data in the other drive. This RAID  
configuration provides data protection and increases fault tolerance to the entire system. Use  
two new drives or use an existing drive and a new drive for this setup. The new drive must be  
of the same size or larger than the existing drive.  
RAID 10 is data striping and data mirroring combined without parity (redundancy data) having  
to be calculated and written. With the RAID 10 configuration you get all the benefits of both  
RAID 0 and RAID 1 configurations. Use four new hard disk drives or use an existing drive and  
three new drives for this setup.  
RAID 5 stripes both data and parity information across three or more hard disk drives. Among  
the advantages of RAID 5 configuration include better HDD performance, fault tolerance, and  
higher storage capacity. The RAID 5 configuration is best suited for transaction processing,  
relational database applications, enterprise resource planning, and other business systems.  
Use a minimum of three identical hard disk drives for this setup.  
If you want to boot the system from a hard disk drive included in a created RAID set, copy  
first the RAID driver from the support DVD to a floppy disk before you install an operating  
system to the selected hard disk drive.  
5-3  
ASUS P9D-C Series  
 
5.1.2  
Installing hard disk drives  
The motherboard supports Serial ATA for RAID set configuration. For optimal performance,  
install identical drives of the same model and capacity when creating a disk array.  
To install the SATA hard disks for RAID configuration:  
1.  
2.  
3.  
Install the SATA hard disks into the drive bays following the instructions in the system  
user guide.  
Connect a SATA signal cable to the signal connector at the back of each drive and to  
the SATA connector on the motherboard.  
Connect a SATA power cable to the power connector on each drive.  
5.1.3  
Setting Jumpers  
Ensure to turn off power before setting the jumpers on the motherboard.  
You must set the jumper settings of your motherboard to activate the embedded Intel® Rapid  
Storage Technology enterprise SATA Option ROM Utility.  
To set the jumper settings for Intel® Rapid Storage Technology enterprise SATA Option  
ROM Utility, set the 3-pin RAID_SEL1 jumper to pins 2-3.  
For more information about the jumper settings of 3-pin RAID_SEL1, you may refer to the  
RAID configuration utility section on page 2-27.  
5.1.4  
Setting the RAID mode in BIOS  
You must set the RAID mode in the BIOS Setup to be able to launch the RAID utilities before  
you can create a RAID set from the SATA hard disk drives attached to the SATA connectors  
supported by Intel® C224 chipset.  
To do this:  
1.  
2.  
3.  
4.  
Enter the BIOS Setup during POST.  
Go to the Advanced Menu > SATA Configuration, then press <Enter>.  
Set SATA Mode to �RAID.  
Press <F10> to save your changes and exit the BIOS Setup.  
Refer to Chapter 4 for details on entering and navigating through the BIOS Setup.  
5.1.5  
RAID configuration utilities  
Depending on the RAID connectors that you use, you can create a RAID set using the utilities  
embedded in each RAID controller. For example, use the Intel® Rapid Storage Technology  
enterprise SATA Option ROM Utility if you installed Serial ATA hard disk drives on the Serial  
ATA connectors supported by the Intel® C224 chipset.  
5-4  
Chapter 5: RAID configuration  
5.2  
Intel® Rapid Storage Technology enterprise SATA  
Option ROM Utility  
The Intel® Rapid Storage Technology enterprise SATA Option ROM utility allows you to create  
RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives  
that are connected to the Serial ATA connectors supported by the Southbridge.  
Before you proceed, ensure that you have installed the Serial ATA hard disk drives, have  
set the correct jumper settings of the motherboard, and have set the correct SATA mode in  
the BIOS setup. You can refer to sections 5.1.2 Installing hard disk drives, 5.1.3 Setting  
Jumpers, and 5.1.4 Setting the RAID mode in BIOS for more information.  
To launch the Intel® Rapid Storage Technology enterprise SATA Option ROM utility:  
1.  
2.  
Turn on the system.  
During POST, press <Ctrl>+<I> to display the utility main menu.  
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023  
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.  
[ MAIN MENU ]  
1. Create RAID Volume  
2. Delete RAID Volume  
3. Reset Disks to Non-RAID  
4. Exit  
[ DISK/VOLUME INFORMATION]  
RAID Volumes:  
None defined.  
Physical Disks:  
ID Drive Model  
Serial #  
HWAS0000991753TR  
37VN00009846RAJ1  
397600009846UEDY  
GWC50000991756G6  
Size  
279.3GB  
279.3GB  
279.3GB  
279.3GB  
Type/Status(Vol ID)  
Non-RAID Disk  
Non-RAID Disk  
Non-RAID Disk  
Non-RAID Disk  
0
1
2
3
ST3300656SS  
ST3300656SS  
ST3300656SS  
ST3300656SS  
[
]-Select  
[ESC]-Exit  
[ENTER]-Select Menu  
The navigation keys at the bottom of the screen allow you to move through the menus  
and select the menu options.  
The RAID BIOS setup screens shown in this section are for reference only and may not  
exactly match the items on your screen.  
5-5  
ASUS P9D-C Series  
 
5.2.1  
Creating a RAID set  
To create a RAID set:  
1.  
2.  
From the utility main menu, select 1. Create RAID Volume and press <Enter>.  
Key in a name for the RAID set from the following screen and press <Enter>.  
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023  
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.  
[ CREATE VOLUME MENU ]  
Name: Volume0  
RAID Level: RAID0(Strips)  
Disks: Select Disks  
Strip Size: 128KB  
Capacity: 0.0 GB  
Syne: N/A  
Create Volume  
[ HELP ]  
Enter a unique volume name that has no special characters and is  
16 characters or less.  
[
]Change  
[TAB]-Next  
[ESC]-Previous Menu  
[ENTER]-Select  
3.  
4.  
Press the up/down arrow keys to select a RAID Level that you wish to create then  
press <Enter>.  
From the Disks item field, press <Enter> to select the hard disk drives that you want to  
include in the RAID set.  
[ SELECT DISKS ]  
Port Drive Model  
Serial #  
Size  
Status  
0
1
2
3
ST3300656SS  
ST3300656SS  
ST3300656SS  
ST3300656SS  
HWAS0000991753TR  
37VN00009846RAJ1  
397600009846UEDY  
GWC50000991756G6  
279.3GB  
279.3GB  
279.3GB  
279.3GB  
Non-RAID Disk  
Non-RAID Disk  
Non-RAID Disk  
Non-RAID Disk  
Select 2 disks to create volume.  
]-Prev/Next [TAB]-(M)aster [SPACE]-(R)ecovery [ENTER]-Done  
[
5.  
Use the up/down arrow keys to move the selection bar then press <Space> to select a  
disk. A small triangle before the Port number marks the selected drive. Press <Enter>  
when you are done.  
5-6  
Chapter 5: RAID configuration  
6.  
Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0,  
10 and 5 only) then press <Enter>. The available stripe size values range from 4 KB to  
128 KB. The following are typical values:  
RAID 0: 128KB  
RAID 10: 64KB  
RAID 5: 64KB  
We recommend a lower stripe size for server systems, and a higher stripe size for  
multimedia computer systems used mainly for audio and video editing.  
7.  
In the Capacity field item, key in the RAID volume capacity that you want to use and  
press <Enter>. The default value indicates the maximum allowed capacity.  
8.  
9.  
Press <Enter> to start creating the RAID volume.  
From the following warning message, press <Y> to create the RAID volume and return  
to the main menu, or press <N> to go back to the CREATE VOLUME menu  
WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST.  
Are you sure you want to create this volume? (Y/N):  
5-7  
ASUS P9D-C Series  
5.2.2  
Deleting a RAID set  
Take caution when deleting a RAID set. You will lose all data on the hard disk drives when  
you delete a RAID set.  
To delete a RAID set:  
1.  
2.  
From the utility main menu, select 2. Delete RAID Volume and press <Enter>.  
From the Delete Volume Menu, press the up/down arrow keys to select the RAID set  
you want to delete then press <Del>.  
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023  
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.  
[ DELETE VOLUME MENU ]  
Name  
Volume0  
Level  
RAID0(Stripe)  
Drives  
2
Capacity  
298.0GB  
Status  
Normal  
Bootable  
Yes  
[ HELP ]  
Deleting a volume will reset the disks to non-RAID  
WARNING: ALL DISK DATA WILL BE DELETED.  
(This does not apply to Recovery volumes)  
[
]-Select  
[ESC]-Previous Menu  
[DEL]-Delete Volume  
3.  
From the following warning message, press <Y> to delete the RAID set and return to  
the utility main menu, or press <N> to return to the DELETE VOLUME menu.  
[ DELETE VOLUME VERIFICATION ]  
ALL DATA IN THE VOLUME WILL BE LOST!  
(This does not apply to Recovery volumes)  
Are you sure you want to delete volume “Volume0”? (Y/N):  
5-8  
Chapter 5: RAID configuration  
5.2.3  
Resetting disks to Non-RAID  
Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a  
RAID volume hard disk drive deletes all internal RAID structure on the drive.  
To reset a RAID set hard disk drive:  
1.  
2.  
From the utility main menu, select 3. Reset Disks to Non-RAID and press <Enter>.  
Press the up/down arrow keys to select the drive(s) or disks of the RAID set you want  
to reset, then press <Space>. A small triangle before the Port number marks the  
selected drive. Press <Enter> when you are done.  
[ RESET RAID DATA ]  
Resetting RAID disk will remove its RAID structures  
and revert it to a non-RAID disk.  
WARNING: Resetting a disk causes all data on the disk to be lost.  
(This does not apply to Recovery volumes)  
Port Drive Model  
Serial #  
HWAS0000991753TR  
37VN00009846RAJ1  
Size  
279.3GB  
279.3GB  
Status  
Member Disk  
Member Disk  
0
1
ST3300656SS  
ST3300656SS  
Select the disks that should be reset.  
]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete  
[
3.  
Press <Y> in the confirmation window to reset the drive(s) or press <N> to return to the  
utility main menu.  
5-9  
ASUS P9D-C Series  
5.2.4  
Exiting the Intel® Rapid Storage Technology enterprise  
SATA Option ROM utility  
To exit the utility:  
1.  
2.  
From the utility main menu, select 4. Exit then press <Enter>.  
From the following warning message, press <Y> to exit or press <N> to return to the  
utility main menu.  
[ CONFIRM EXIT ]  
Are you sure you want to exit? (Y/N):  
5.2.5  
Rebuilding the RAID  
This option is only for the RAID 1 set.  
Rebuilding the RAID with other non-RAID disk  
If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays  
the status of the RAID volume as “Degraded” during POST. You can rebuild the RAID array  
with other installed non-RAID disks.  
To rebuild the RAID with other non-RAID disk:  
1.  
During POST, press <Ctrl>+<I> at the prompt to enter the Intel Rapid Storage  
Technology option ROM utility.  
2.  
If there is a non-RAID SATA Hard Disk available, the utility will prompt you to rebuild the  
RAID. Press the up/down arrow keys to select the destination disk then Press <Enter>  
to start the rebuilding process or press <ESC> to exit.  
[ DEGRADED VOLUME DETECTED ]  
“Degraded” volume and disk available for rebuilding detected. Selectign  
a disk initiates a rebuild. Rebuild completes in the operating system.  
Select the port of destination disk for rebuilding (ESC to exit):  
Port Drive Model  
XXXXXXXXXXX  
Serial #  
XXXXXXXX  
Size  
XXX.GB  
X
[
]-Previous/Next [ENTER]-Select [ESC]-Exit  
Select a destination disk with the same size as the original hard disk.  
5-10  
Chapter 5: RAID configuration  
3.  
The utility immediately starts rebuilding after the disk is selected. The status of the  
degraded RAID volume is changed to “Rebuild”.  
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023  
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.  
[ MAIN MENU ]  
1. Create RAID Volume  
2. Delete RAID Volume  
3. Reset Disks to Non-RAID  
4. Exit  
[ DISK/VOLUME INFORMATION]  
RAID Volumes:  
*=Data is Encrypted  
ID  
1
Name  
Level1  
RAID1(Mirror)  
Strip  
N/A  
Size  
149.0GB  
Status  
Bootable  
Yes  
Volume0  
Rebuild  
Physical Devices:  
Port Drive Model  
Serial #  
9LS0F4HL  
3LS0JYL8  
Size  
Type/Status(Vol ID)  
Member Disk(0)  
Member Disk(0)  
1
2
ST3160812AS  
ST3160812AS  
149.0GB  
149.0GB  
Volumes with “Rebuild” status will be rebuilt within the operating system.  
[
]-Select  
[ESC]-Exit  
[ENTER]-Select Menu  
4.  
5.  
Exit Intel Rapid Storage Technology and reboot the system.  
Select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console or  
click the Intel Rapid Storage Technology tray icon to load the Intel Rapid Storage  
Manager utility.  
6.  
7.  
From the View menu, select Advanced Mode to display the details of the Intel Rapid  
Storage Console.  
From the Volumes view option, select RAID volume to view the rebuilding status.  
When finished, the status is changed to “Normal”.  
Rebuilding the RAID with a new hard disk  
If any of the SATA hard disk drives included in the RAID array failed, the system displays the  
status of the RAID volume as “Degraded” during POST. You may replace the disk drive and  
rebuild the RAID array.  
To rebuild the RAID with a new hard disk:  
1.  
Remove the failed SATA hard disk and install a new SATA hard disk of the same  
specification into the same SATA Port.  
Select a destination disk with the same size as the original hard disk.  
2.  
Reboot the system then follow the steps in section Rebuilding the RAID with other  
non-RAID disk.  
5-11  
ASUS P9D-C Series  
5.2.6  
Setting the Boot array in the BIOS Setup Utility  
You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-  
RAID using the Intel® Rapid Storage Technology enterprise SATA Option ROM utililty.  
To set the boot array in the BIOS:  
Set at least one of the arrays bootable to boot from the hard disk.  
1.  
2.  
3.  
Reboot the system and press <Del> to enter the BIOS setup utility during POST.  
Go to the Boot menu and select the boot option priority.  
Use up/down arrow keys to select the boot priority and press <Enter>. See the Boot  
menu section of Chapter 4 for more details.  
4.  
From the Exit menu, select Save Changes & Exit, then press <Enter>.  
5.  
When the confirmation window appears, select Yes, then press <Enter>.  
5-12  
Chapter 5: RAID configuration  
5.3  
Intel® Rapid Storage Technology enterprise  
(Windows)  
The Intel® Rapid Storage Technology enterprise allows you to create RAID 0, RAID 1, RAID 10  
(RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial  
ATA connectors supported by the Southbridge.  
You need to manually install the Intel® Rapid Storage Technology enterprise utility on a  
Windows® operating system. Please refer to the installation instructions in Chapter 6.  
To enter the Intel® Rapid Storage Technology enterprise utility under Windows operating  
system:  
1.  
2.  
Turn on the system to windows desktop.  
Click the Intel® Rapid Storage Technology enterprise icon to display the main menu.  
Your storage system is configured for data protection, increased performance and optimal data  
storage capacity. You can create additional volumes to further optimize your storage system.  
You can click Rescan to re-scan any attached hard disks.  
5-13  
ASUS P9D-C Series  
 
5.3.1  
Creating a RAID set  
To create a RAID set:  
1.  
2.  
From the utility main menu, select Create Volume and select volume type.  
Click Next.  
3.  
4.  
5.  
Enter a name for the RAID set, then select the array disks.  
Select Volume Size tab, you can drag the bar to decide the volume size.  
Click Next.  
If you do not want to keep the data on one of the selected disks, select NO when  
prompted.  
If you want to Enable volume write-back cache or Initialize volume, click  
Advanced.  
5-14  
Chapter 5: RAID configuration  
6.  
Confirm the volume creation, than click Create Volume to continue.  
This process could take a while depending on the number and size of the disks. You can  
continue using other applications during this time.  
7.  
Wait until the process is completed, then click OK when prompted.  
You still need to partition your new volume using Windows Disk Management before adding  
any data.  
The RAID set is displayed in the Volumes list and you can change the settings in Volume  
Properties.  
5-15  
ASUS P9D-C Series  
5.3.2  
Changing a Volume Type  
To change the volume type in Volume Properties:  
1.  
2
Click the SATA array items you want to change in Volumes field.  
From the Volume Properties field, select Type:RAID 1 Change type.  
3.  
4.  
You can change the Name, Select the new volume type, and Select additional disks  
to include in the new volume if needed.  
Select the Data stripe size for the RAID array (for RAID 0, 10 and 5 only), and click  
OK. The available stripe size values range from 4 KB to 128 KB. The following are  
typical values:  
RAID 0: 128KB  
RAID 10: 64KB  
RAID 5: 64KB  
We recommend a lower stripe size for server systems, and a higher stripe size for multimedia  
computer systems used mainly for audio and video editing.  
5-16  
Chapter 5: RAID configuration  
5.3.3  
Deleting a volume  
Be cautious when deleting a volume. You will lose all data on the hard disk drives.Before  
you proceed, ensure that you back up all your important data from your hard drives.  
To delete a volume:  
1.  
From the utility main menu, select the volume (exp. Volume_0000) in Volumes field you  
want to delete.  
2.  
Select Delete volume in Volume Properties field. The following screen appears.  
3.  
Click Yes to delete the volume and return to the utility main menu, or click No to return  
to the main menu.  
5-17  
ASUS P9D-C Series  
5.3.4  
Preferences  
System Preferences  
Allow you to set to show the notification area icon and show system information, warning, or  
errors here.  
E-Mail Preferences  
Allow you to set to sent e-mail of the following events:  
Storage system information  
Storage system warnings  
Storage system errors  
5-18  
Chapter 5: RAID configuration  
Chapter 6:  
Driver installation  
6.1  
RAID driver installation  
After creating the RAID sets for your server system, you are now ready to install an  
operating system to the independent hard disk drive or bootable array. This part provides the  
instructions on how to install the RAID controller drivers during OS installation.  
6.1.1  
Creating a RAID driver disk  
The system does not include a floppy drive. You have to use a USB floppy drive when  
creating a SATA RAID driver disk.  
A floppy disk with the RAID driver is required when installing Windows® or Red Hat®  
Enterprise operating system on a hard disk drive that is included in a RAID set. You can  
create a RAID driver disk in DOS (using the Makedisk application in the support DVD).  
To create a RAID driver disk in DOS environment:  
1.  
2.  
3.  
4.  
Place the motherboard support DVD in the optical drive.  
Restart your computer.  
Enter the BIOS Setup.  
Select the optical drive as the first boot priority to boot from the support DVD. Save  
your changes.  
5.  
6.  
Exit the BIOS Setup and restart your computer.  
The following Makedisk menu appears.  
Select the C22x INTEL RAID Driver and press <Enter> to go to the sub-menu.  
Create Driver Diskette Menu  
C22x INTEL RAID Driver  
Write DMI  
FreeDOS command prompt  
7.  
From the C22x Intel RAID Driver sub-menu, use the Up or Down arrow keys to select the  
driver and press <Enter> to create the RAID driver disk.  
C22x INTEL RAID Driver  
Windows 64 bit(AHCI / AHCI RAID)  
Windows Server 2012 64 bit (AHCI / AHCI RAID)  
Back  
Exit  
ASUS P9D-C Series  
6-3  
 
6.  
Select YES from the following warning message then press <Enter>.  
WARNING !!!  
)ADLOLYDOAUTAWAONNT TTHOECFOLNOTPIPNYUEDI?SKETTE WILL BE DELETED !!  
YES  
NO  
7.  
On the following Important message, select YES if an ASMB7 is installed, otherwise  
select NO, then press <Enter>.  
<Important>  
Please ensure ASMB7-iKVM is well installed on the  
motherboard.  
YES  
NO  
8.  
9.  
Insert the formatted diskette into the disk drive and press <Enter>. The system writes  
the image to the disk.  
Press any key to continue when prompted.  
The Create Driver Diskette Menu appears after the creation of the diskette is finished.  
To create a RAID driver disk in Windows® environment:  
1.  
2.  
3.  
4.  
5.  
Start Windows®.  
Place the motherboard support DVD into the optical drive.  
Go to the Make disk menu, then select the type of RAID driver disk you want to create.  
Insert a floppy disk into the USB floppy disk drive.  
Follow succeeding screen instructions to complete the process.  
Write-protect the floppy disk to avoid computer virus infection.  
6-4  
Chapter 6: Driver installation  
6.1.2  
Installing the RAID controller driver  
During Windows® Server 2008 OS installation  
To install the RAID controller driver when installing Windows® Server 2008 OS  
1.  
Boot the computer using the Windows® Server 2008 OS installation disc. Follow the screen  
instructions to start installing Windows Server 2008.  
2.  
When prompted to choose a type of installation, click Custom (advanced).  
3.  
Click Load Driver.  
ASUS P9D-C Series  
6-5  
4.  
A message appears, reminding you to insert the installation media containing the driver  
of the RAID controller driver. If you have only one optical drive installed in your system,  
eject the Windows OS installation disc and replace with the motherboard Support DVD  
into the optical drive. Click Browse to continue.  
5.  
Locate the driver in the corresponding folder of the Support DVD, and then click OK to  
continue.  
6.  
Select the RAID controller driver you need from the list and click Next.  
7.  
When the system finishes loading the RAID driver, replace the motherboard Support DVD  
with the Windows Server installation disc. Select the drive to install Windows and click  
Next.  
8.  
Setup then proceeds with the OS installation. Follow screen instructions to continue.  
6-6  
Chapter 6: Driver installation  
6.2  
Management applications and utilities  
installation  
The support DVD that is bundled with your motherboard contains drivers, management  
applications, and utilities that you can install to maximize the features of your  
motherboard.  
1. The contents of the support DVD are subject to change at any time without notice.  
Visit the ASUS website (www.asus.com) for the latest updates on software and  
utilities.  
2. The support DVD is supported on Windows® Server 2008 R2 and Windows®  
Server 2012.  
6.3  
Running the Support DVD  
When you place the support DVD into the optical drive, the DVD automatically displays  
the main screen if Autorun is enabled in your computer. By default, the Drivers tab is  
displayed.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to  
run the support DVD.  
The main screen of the Support DVD contains the following tabs:  
1.  
2.  
3.  
4.  
5.  
Drivers  
Utilities  
MakeDisk  
Manual  
Contact  
The main screen of the Support DVD looks exactly the same on the Windows® Server  
2008 R2 and on the Windows® Server 2012 Operating System (OS).  
ASUS P9D-C Series  
6-7  
 
6.3.1  
Drivers menu tab  
The Drivers Menu shows the available device drivers if the system detects installed devices.  
Install the necessary drivers to activate the devices.  
6.3.2  
Utilities menu tab  
The Utilities menu displays the software applications and utilities that the motherboard  
supports.  
6-8  
Chapter 6: Driver installation  
6.3.3  
MakeDisk menu tab  
The MakeDisk menu contains items to create the Intel RAID driver disks.  
You have to press the arrow down button in the lower part of the screen to view the  
remaining items of the MakeDisk menu.  
6.3.4  
Manual menu  
The Manual menu provides the link to the Broadcom NetXtreme II Network Adapter  
user guide.  
You need an internet browser installed in your OS to view the User Guide.  
ASUS P9D-C Series  
6-9  
6.3.5  
Contact information menu  
The Contact menu displays the ASUS contact information, e-mail addresses, and  
useful links if you need more information or technical support for your motherboard.  
6.3.6  
Installing the Intel® Chipset device Software driver  
This section provides the instructions on how to install the Intel® chipset device software on  
the system.  
You need to manually install the Intel® chipset device software on a Windows® Operating  
System.  
To install the Intel® chipset device software on Windows® Server 2008 R2:  
1.  
2.  
3.  
Restart the computer.  
Log with Administrator privileges.  
Insert the Motherboard Support DVD to the optical drive.  
The support DVD automatically displays the Drivers menu if Autorun is enabled in your  
computer.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run  
the support DVD.  
4.  
Click Intel® Chipset Device Software from the Drivers menu to start the installation.  
6-10  
Chapter 6: Driver installation  
5.  
From the Intel® Chipset Device  
Software, click Next to start the  
installation.  
6.  
In the License Agreement window,  
click Yes to continue.  
7.  
Read the Readme File information and  
click Next to continue.  
ASUS P9D-C Series  
6-11  
8.  
Click Install in the Windows Security  
window.  
The Windows Security window may appear more than once and you may have to click  
Install several times to continue with the installation.  
9.  
When the installation of files is finish, click  
Next.  
10. When prompted to restart the computer,  
select Yes, I want to restart this  
computer now then click Finish to  
complete the installation.  
6-12  
Chapter 6: Driver installation  
To install the Intel® Chipset device software on Windows® Server 2012:  
1.  
2.  
3.  
Restart the computer.  
Log with Administrator privileges.  
Insert the Motherboard Support DVD to the optical drive.  
The support DVD automatically displays the Drivers menu if Autorun is enabled in your  
computer.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run  
the support DVD.  
4.  
5.  
Click Intel® Chipset Device Software from the Drivers menu to start the installation.  
From the Intel® Chipset Device  
Software, click Next.  
6.  
In the License Agreement window,  
click Yes to continue the process.  
ASUS P9D-C Series  
6-13  
7.  
Read the Readme File information and  
click Next to continue.  
8.  
When the loading fo files is finish, click  
Finish to complete the installation.  
6-14  
Chapter 6: Driver installation  
6.4  
Installing the LAN driver  
This section provides the instructions on how to install the Intel® Network Connections  
Software drivers on the system.  
You need to manually install the LAN controller driver on a Windows® operating system.  
To install the LAN controller device on Windows® Server 2008 R2:  
1.  
2.  
3.  
Restart the computer.  
Log with Administrator privileges.  
Insert the Motherboard Support DVD to the optical drive.  
The support DVD automatically displays the Drivers menu if Autorun is enabled in your  
computer.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run  
the support DVD.  
4.  
Click Intel® Network Connections  
Software on the Drivers menu to start  
the installation.  
5.  
From the Intel® Network Connections  
window, click Install Drivers and  
Software.  
ASUS P9D-C Series  
6-15  
 
6.  
Click Next in the Welcome to the  
InstallShield Wizard for Intel(R) Network  
Connections.  
7.  
Toggle I accept the terms in the license  
agreement then click Next in the License  
Agreement window.  
8.  
Select the drivers you want to install in the  
Setup Options window and click Next.  
9.  
From the Ready to Install the Program  
window, click Install.  
6-16  
Chapter 6: Driver installation  
10. Click Yes when the Microsoft  
Management Console dialog box  
appears.  
The Microsoft Management  
Console dialog box appears when  
the system detects open or running  
applications that needs to be closed.  
You have to terminate open or  
running applications specified in  
the dialog box to proceed with the  
installation.  
11. When the loading of drivers is  
finish, click Finish to complete the  
installation.  
To install the LAN controller device on Windows® Server 2012:  
1.  
2.  
3.  
Restart the computer.  
Log with Administrator privileges.  
Insert the Motherboard Support DVD to the optical drive.  
The support DVD automatically displays the Drivers menu if Autorun is enabled in your  
computer.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run  
the support DVD.  
4.  
Click Intel® Network Connections Software on the Drivers menu to start the  
installation.  
ASUS P9D-C Series  
6-17  
5.  
From the Intel® Network Connections  
window, click Install Drivers and  
Software.  
6.  
Click Next in the Welcome to the  
InstallShield Wizard for Intel(R) Network  
Connections window.  
7.  
Select the drivers you want to install in  
the Setup Options window and click  
Next.  
6-18  
Chapter 6: Driver installation  
8.  
Click Install to continue.  
9.  
When the the installation of files is finish,  
click Finish to complete the installation.  
ASUS P9D-C Series  
6-19  
6.5  
Installing the VGA driver  
This section provides the instructions on how to install the ASPEED Video Graphics  
Adapter (VGA) driver.  
You need to manually install the ASPEED Video Graphics Adapter (VGA) driver on a  
Windows® operating system.  
To install the ASPEED VGA driver on Windows® Server 2008 R2:  
1.  
2.  
3.  
Restart the computer.  
Log with Administrator privileges.  
Insert the Motherboard Support DVD to the optical drive.  
The support DVD automatically displays the Drivers menu if Autorun is enabled in your  
computer.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run  
the support DVD.  
The Main menu of the Support DVD  
appears.  
4.  
Click ASPEED AST2300/AST1300  
Display Driver on the Drivers menu to  
start the installation.  
5.  
Toggle I accept the terms in the license  
agreement and click Next in the License  
Agreement window.  
6-20  
Chapter 6: Driver installation  
 
6.  
Enter a username and organization  
then click Next.  
7.  
Toggle Complete in the Setup Type  
window then click Next.  
8.  
Click Install to begin the installation.  
9.  
When the the installation of files is  
complete, click Finish.  
ASUS P9D-C Series  
6-21  
10. When prompted to restart the  
computer, click Yes.  
To install the ASPEED VGA driver on Windows® Server 2012:  
1.  
2.  
3.  
Restart the computer.  
Log with Administrator privileges.  
Insert the Motherboard Support DVD to the optical drive.  
The support DVD automatically displays the Drivers menu if Autorun is enabled in your  
computer.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run  
the support DVD.  
4.  
5.  
Click ASPEED AST2300/AST1300 Display Driver on the Drivers menu to start the  
installation.  
Click OK in the Driver Information window.  
Wait for the loading of drivers to finish.  
6.  
Click OK to complete the installation.  
6-22  
Chapter 6: Driver installation  
6.6  
Installing the Intel® C22x MEI NULL HECI driver  
This section provides the instructions on how to install the Intel® C22x MEI NULL HECI driver  
on the motherboard.  
To install the Intel® C22x MEI NULL HECI driver in Windows:  
1.  
2.  
3.  
Restart the computer.  
Log on with Administrator privileges.  
Insert the motherboard/system support DVD to the optical drive.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run  
the support DVD.  
4.  
Click Intel® C22x MEI NULL HECI on the  
Drivers menu of the main screen to start  
the installation.  
5.  
The Welcome to the Setup Program  
window appears. Click Next.  
6.  
Click Yes in the License Agreement  
window to continue with the installation.  
ASUS P9D-C Series  
6-23  
 
9.  
Click NEXT when the installation of  
driver is complete.  
10. Click Finish to complete the  
installation.  
6-24  
Chapter 6: Driver installation  
6.7  
Installing the Intel® I210 Gigabit Adapter driver  
This section provides the instructions on how to install the Intel® I210 Gigabit Adapter  
driver on the system.  
To install the Intel® I210 Gigabit Adapter driver on Windows® Server 2008 R2:  
1.  
2.  
3.  
Restart the computer.  
Log on with Administrator privileges.  
Insert the motherboard/system support DVD to the optical drive.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run  
the support DVD.  
4.  
Click Intel® I210 Gigabit Adapter Driver  
in the Drivers menu of the main screen  
to start the installation.  
5.  
Click Next to continue.  
6.  
Toggle Modify then click Next in the  
Program Maintenance window.  
ASUS P9D-C Series  
6-25  
 
7.  
Select the options you want to install then  
click Next to continue.  
8.  
Click Install in the Ready to Modify the  
Program window to begin with the loading  
of the selected options.  
9.  
When the the installation of files is  
complete, click Finish.  
6-26  
Chapter 6: Driver installation  
To install the Intel® I210 Gigabit Adapter driver on Windows® Server 2012:  
1.  
2.  
3.  
Restart the computer.  
Log on with Administrator privileges.  
Insert the motherboard/system support DVD to the optical drive.  
If Autorun is NOT enabled in your computer, browse the contents of the support DVD to  
locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run  
the support DVD.  
4.  
5.  
Click Intel® I210 Gigabit Adapter Driver in the Drivers menu of the main screen to  
start the installation.  
Click Next to continue.  
6.  
Toggle Modify then click Next in the  
Program Maintenance window.  
7.  
Select the options you want to install then  
click Next to continue.  
ASUS P9D-C Series  
6-27  
8.  
In the Ready to Modify the Program  
window, click Install to load the options you  
selected.  
9.  
When the the installation of files is  
complete, click Finish.  
6-28  
Chapter 6: Driver installation  
Appendix A:  
Reference Information  
A
Chapter summary  
This appendix includes additional information that you may refer to when  
configuring the motherboard. This chapter contains the following sections:  
ASUS P9D-C Series  
A.1  
P9D-C/4L block diagram  
A-3  
ASUS P9D-C Series  
 
A.2  
P9D-C/2L block diagram  
A-4  
Appendix A: Reference information  
 
ASUS contact information  
ASUSTeK COMPUTER INC.  
Address  
Telephone  
Fax  
E-mail  
Web site  
15 Li-Te Road, Peitou, Taipei, Taiwan 11259  
+886-2-2894-3447  
+886-2-2890-7798  
info@asus.com.tw  
http://www.asus.com.tw  
Technical Support  
Telephone  
+86-21-38429911  
Fax  
+86-21-58668722 ext: 9101  
Online Support  
http://support.asus.com/techserv/techserv.aspx  
ASUSTeK COMPUTER INC. (Taiwan)  
Address  
Telephone  
Fax  
E-mail  
Web site  
15 Li-Te Road, Peitou, Taipei, Taiwan 11259  
+886-2-2894-3447  
+886-2-2890-7798  
info@asus.com.tw  
http://www.asus.com.tw  
Technical Support  
Telephone  
+886-2-2894-3447 (0800-093-456)  
Online Support  
http://support.asus.com/techserv/techserv.aspx  
ASUSTeK COMPUTER INC. (China)  
Address  
No.508, Chundong Road, Xinzhuang Industrial Zone,  
Minhang District, Shanghai, China.  
+86-21-5442-1616  
+86-21-5442-0099  
Telephone  
Fax  
Web site  
http://www.asus.com.cn  
Technical Support  
Telephone  
+86-21-3407-4610 (800-820-6655)  
Online Support  
http://support.asus.com/techserv/techserv.aspx  
ASUS contact information  
ASUS COMPUTER INTERNATIONAL (America)  
Address  
800 Corporate Way, Fremont, CA 94539, USA  
Fax  
+1-510-608-4555  
Web site  
http://usa.asus.com  
Technical Support  
Support fax  
+1-812-284-0883  
General support  
Online support  
+1-812-282-2787  
http://support.asus.com/techserv/techserv.aspx  
ASUS COMPUTER GmbH (Germany and Austria)  
Address  
Harkort Str. 21-23, D-40880 Ratingen, Germany  
Fax  
+49-2102-959911  
Web site  
Online contact  
http://www.asus.de  
http://www.asus.de/sales  
Technical Support  
Telephone +49-1805-010923  
Support Fax +49-2102-959911  
Online support http://support.asus.com/techserv/techserv.aspx  
ASUS Czech Service s.r.o. (Europe)  
Address Na Rovince 887, 720 00 Ostrava – Hrabová, Czech  
Republic  
Telephone +420-596766888  
Web site http://www.asus.cz  
Technical Support  
Telephone +420-596-766-891  
Fax +420-596-766-329  
E-mail advance.rma.eu@asus.com  
Online Support http://support.asus.com/techserv/techserv.aspx  
ASUS contact information  
ASUS Holland BV (The Netherlands)  
Address  
Marconistraat 2, 7825GD EMMEN, The Netherlands  
Web site  
http://www.asus.com  
Technical Support  
Telephone  
+31-(0)591-5-70292  
Fax  
+31-(0)591-666853  
E-mail  
Online Support  
advance.rma.eu@asus.com  
http://support.asus.com/techserv/techserv.aspx  
ASUS Polska Sp. z o.o. (Poland)  
Address  
Ul. Postępu 6, 02-676 Warszawa, Poland  
Web site  
http://pl.asus.com  
Technical Support  
Telephone  
+48-225718033  
Online Support  
http://support.asus.com/techserv/techserv.aspx  
ASK-Service (Russia and CIS)  
Address  
г.Москва, ул. Орджоникидзе, д.10, Россия  
Telephone  
Web site  
(495) 640-32-75  
http://ru.asus.com  
Technical Support  
Telephone  
008-800-100-ASUS (008-800-100-2787)  
Online Support  
http://vip.asus.com/eservice/techserv.aspx?SLanguage=ru  

Hitachi Computer Drive 4K80 User Manual
GE Monogram ZGU48N4G User Manual
Fujitsu FM3 32 Bit Microcontroller MB9B500A User Manual
Envision Peripherals Envision Professional G912WA2 User Manual
Eizo EIZO FlexScan S2001W User Manual
Cypress ISR 37000 CPLD User Manual
BT Verve 100 User Manual
Black Decker CTO6305 User Manual
AT T CL81211 User Manual
AMD 7ZMMC User Manual