Toshiba Computer Drive NC1 User Manual

ADJUSTABLE SPEED DRIVES  
nC1 Drive  
Easy-to-Use  
Easy To Program  
The nC1 uses a simple, straightforward programming menu for quick and  
easy setup of the drive. There are no complicated sub menus or “hidden”  
parameters. By using the built-in programming wizards, the nC1 can be  
programmed for simple operations with the push of a button. Available  
®
Windows programming software makes it a snap to set up the drive.  
User-Friendly Operation  
The nC1 comes ready to run. Simply mount the drive, run your power  
connections and you are ready for operation. Many operations require  
no programming whatsoever. The user-friendly interface is designed to  
set the speed and start/stop functions of the unit easily. The drive will also  
operate from nearly any standard industrial control inputs.  
Array of Communications  
In today’s fast-paced manufacturing world, coordinated systems require  
communications from drive-to-drive and drive-to-system. A built-in port and a  
variety of option cards give you versatility in communication selection.  
Built-In RS232/RS485 Port  
Communication Protocol Options  
- Ethernet TCP/IP  
- Ethernet IP  
- DeviceNet  
- Modbus RTU  
- Modbus Plus  
- Johnson Controls Metasys N2  
- Profibus DP  
nC1 Drive  
Full-Scale  
CHARGE Lamp  
Display  
Displays the operating frequency,  
parameter information, a monitored  
item, the cause of a failure,  
and so on.  
Input  
Terminals  
Indicates that high voltage is still  
present within the inverter. Do not  
open the cover while this is lit.  
MONITOR Key  
PROGRAM Lamp  
Lights when the inverter is in  
parameter setting mode. This lamp  
blinks when the parameter “AUH”  
or “Gr.U” is selected.  
Displays operating frequencies,  
parameter, and error messages.  
RUN Lamp  
UP Key  
Lights when an ON command  
is issued but no frequency signal  
is sent out. It blinks when operation  
is started.  
Pressing the up key when lamp is  
on allows the operating frequency  
to be seen.  
STOP Key  
DOWN Key  
Pressing the down key when lamp  
is on allows the operating frequency  
to be seen.  
Pressing of the STOP key while  
the RUN key lamp is on will cause  
a slowdown-stop.  
Built-In  
Potentionmenter  
Output  
Terminals  
ENTER Key  
Standard Specifications  
nC1 ASD Standard Specifications  
Model Range  
1001P-1007P  
2002P-2022P  
2001PL-2022PL  
2002P-2022P  
230 V/Single Phase with  
RFI / EMI Filter  
Input Voltage Rating  
120 V/Single Phase  
230 V/Single Phase  
230 V/Three Phase  
KW Range  
0.1 to 0.75 KW  
1/8 to 1 HP  
0.2 to 2.2 KW  
1/4 to 3 HP  
0.1 to 2.2 KW  
1/8 to 3 HP  
0.2 to 2.2 KW  
1/4 to 3 HP  
HP Range  
Overload Rating  
Input Voltage Tolerance  
Input Frequency Rating  
Input Frequency Tolerance  
Output Voltage Rating  
Color  
150% for 60 Seconds  
+10%, -15%  
50/60 Hz  
± 5%  
+10%, -15%  
50/60 Hz  
±5%  
+10%, -15%  
50/60 Hz  
±5%  
+10%, -15%  
50/60 Hz  
±5%  
230 V, Three Phase  
Munsel 5Y8 / 0.5  
Control System  
Sinusoidal PWM Control  
Adjustable within a Range of 100 to 120% of Corrected Supply Voltage (200 V), Nonadjustable to any Voltage Higher than the Input  
Voltage  
Output Voltage Range  
Output Frequency Range  
Minimum Frequency Step  
0.5 to 200 Hz, Default Setting: 0.5 to 80 Hz, Max Frequency: 30 to 200 Hz  
0.1 Hz: Operation Panel Setting, 0.2 Hz: Analog Input (when the Max Frequency is 100 Hz)  
Digital Setting: within ±0.5% of the Max Frequency (-10 to +50°C)  
Frequency Accuracy  
V/f Characteristics  
Analog Setting: within ±1.0% of the Max Frequency (25°C ± 10°C )  
V/f, Slip Frequency Compensation, Base Frequency, Base Frequency Voltage and Torque Boost (Adjustable Amount)  
Internal Pot on the Front Panel, External Frequency Signal (Connectable to a Volume with a Rated Impedance of 3 to 10 kΩ),  
VI Terminal (Input Impedance: 42 kΩ (Voltage: 0 to 10 Vdc) or 250 Ω (Current: 4 to 20 mAdc)). Frequency can be Set Arbitrarily  
Using a Two Point Setting  
Frequency Setting Signal  
Startup & Jump Frequency  
PWM Carrier Frequency  
Accel/Decel Time  
Adjustable within a Range of 0.5 to 10 Hz; Up to 1 Frequency can be Adjusted Together with its Widths  
Selectable from among 2, 4, 8, 12, and 16 kHz (Standard Default Setting: 12 kHz or 4 kHz for Models with a Built-In EMI Noise Filter)  
Two Selectable Accel/Decel Times Adjustable from 0.1 to 3000 seconds  
Retry Operation  
Selectable Number of Retries (Maximum 10 Times); If Protection Function is activated, Retry Function restarts after a main circuit check.  
Charging of Capacitor (Deceleration Time can be Shortened by Activating Forced Shortened Deceleration Mode)  
Braking Start Frequency: 0 to Max Frequency; Braking Rate: 0 to 100%; Braking Time: 0 to 20 seconds  
Electric Control  
Dynamic Braking  
Input Terminal Functions  
Forward/Reverse Run Input Signal, Jog Run Input Signal, Standby Signal, Preset-Speed Operation Input Signal, Reset Input Signal, etc.  
Frequency Lower Limit Output Signal, Frequency Upper Limit Output Signal, Low-Speed Detection Output Signal, Specified Speed  
Attainment Output Signal, etc., Open Collector, RY Output  
Output Terminal Functions  
Failure Detection Signal  
FM/AM Output  
1 Form C Contact, Rated: 250 Vac, 2A, cosØ = 0.4  
PWM Output: (1 mAdc Full-Scale DC Ammeter or 7.5 Vdc Full-Scale DC Ammeter/Rectifier-Type AC Voltmeter, 225% Current Max  
1 mAdc, 7.5 Vdc Full-Scale)  
Stall Prevention, Current Limitation, Overcurrent, Output Short Circuit, Overvoltage, Overvoltage Limitation, Undervoltage, Ground Fault,  
Power Supply Phase Failure, Output Phase Failure Overload Protection by Electronic Thermal Function, Armature Overload at Startup,  
Load-Side Overtorque at Startup, Overheating Prevention, Detection of Analog Signal Break  
Protective Function  
Momentary Power Failure Protection Auto-Restart Control after Momentary Power Failure  
Electronic Thermal Characteristics  
Switching between Standard Motor/Constant- Torque VF Motor, Overload Trip, Overload Stall Selection  
Frequency: Inverter Output Frequency  
Alarm: Stall Alarm “C,” Overvoltage Alarm “P,” Overload Alarm “L,” Overheat Alarm “H.”  
Status: Inverter Status (Frequency, Cause of Activation of Protective Function, Input / Output Voltage, Output Current, etc.) and Parameter  
Settings  
4-Digit, 7-Segment LED  
Free-Unit Display: Arbitrary Unit (e.g. Rotating Speed) Corresponding to Output Frequency  
Indicator  
Lamps Indicate Inverter Status by Lighting, such as RUN Lamp and PROGRAM Lamp  
2
Indoor-Altitude: 1000 Meters (Maximum), not Exposed to Direct Sunlight, Corrosive Gas, Explosive Gas or Vibration (Less than 5.9 m )  
Use Environments  
(10 to 55 Hz)  
Ambient Temperature  
Storage Temperature  
Relative Humidity  
-10 to +50˚C  
-20 to +65˚C  
20 to 93% Non-Condensing  
Model FLA & Approximate Dimensions (Inches) & Weight (Lbs)  
VOLTAGE  
HP  
MODEL NUMBER  
FLA  
HEIGHT  
WIDTH  
DEPTH  
WEIGHT  
0.12  
0.25  
0.5  
1.0  
0.25  
0.5  
VFNC1S-1001P  
VFNC1S-1002P  
VFNC1S-1004P  
VFNC1S-1007P  
VFNC1S-2002P  
VFNC1S-2004P  
0.7  
1.4  
2.4  
4.0  
1.4  
2.4  
5.6  
5.6  
5.6  
5.6  
5.6  
5.6  
2.8  
2.8  
2.8  
4.6  
2.8  
2.8  
3.9  
3.9  
3.9  
4.9  
3.9  
4.9  
2.2  
2.2  
2.2  
2.2  
2.2  
2.2  
110 V  
Single Phase  
230 V  
Single Phase  
1.0  
2.0  
3.0  
0.12  
0.25  
0.5  
1.0  
2.0  
3.0  
0.25  
VFNC1S-2007P  
VFNC1S-2015P  
VFNC1S-2022P  
VFNC1-2001P  
VFNC1-2002P  
VFNC1-2004P  
VFNC1-2007P  
VFNC1-2015P  
VFNC1-2022P  
VFNC1S-2002PL  
4.0  
7.5  
10  
0.7  
1.4  
2.4  
4.0  
7.5  
10  
5.6  
5.6  
5.6  
5.6  
5.6  
5.6  
5.6  
5.6  
5.6  
5.6  
2.8  
4.6  
4.6  
2.8  
2.8  
2.8  
2.8  
4.6  
4.6  
2.8  
5.4  
6.1  
6.1  
3.9  
3.9  
4.9  
5.4  
6.1  
6.1  
3.9  
2.2  
3.3  
3.3  
2.2  
2.2  
2.2  
2.2  
3.3  
3.3  
2.2  
230 V  
Three Phase  
1.2  
230 V  
Single Phase  
Built-in RFI / EMI Filter  
0.5  
1.0  
2.0  
3.0  
VFNC1S-2004PL  
VFNC1S-2007PL  
VFNC1S-2015PL  
VFNC1S-2022PL  
2.3  
4.0  
7.5  
5.6  
5.6  
5.6  
5.6  
2.8  
2.8  
4.6  
4.6  
4.9  
5.4  
6.1  
6.1  
2.2  
2.2  
3.3  
3.3  
10.7  
North America Headquarters & Manufacturing Facilities (Houston, TX)  
TOSHIBA — Quality by Design  
Toshiba's culture and history are strongly rooted in quality. Our designs are  
technologically innovative, and our products are manufactured from start to  
end using only the highest quality domestic and foreign parts.  
Product Warranty  
Toshiba offers a comprehensive warranty program on its full line of industrial  
products. Consult your salesperson or the factory for specific information.  
Need to Know More?  
information on Toshiba products and services.  
Customer Support Services  
Toshiba offers 24-hour service nationwide. For assistance of any type  
call: 1-800-231-1412.  
ADJUSTABLE SPEED DRIVES  
MOTORS  
CONTROLS  
UPS  
INSTRUMENTATION  
PLC  
Available Through:  
INDUSTRIAL DIVISION  
13131 West Little York Road, Houston, Texas 77041  
Tel 713/466-0277 Fax 713/466-8773  
US 800/231-1412 Canada 800/872-2192 Mexico 01/800/527-1204  
Copyright 8/2007  
* N C 1 b r o c c t 0 7 0 8 1 5 *  

Wibur Curtis Company G3 User Manual
Sony 1264 0776 User Manual
Silicon Laboratories SI5366 User Manual
Seagate Solid State Drive ST120HM000 User Manual
Seagate Barracuda ST340014AS User Manual
Samsung SGH E370 User Manual
Samsung SGH A288 User Manual
Sagem 926 User Manual
Oregon Scientific RM308PU User Manual
Oregon RM962 User Manual