PRODUCT OVERVIEW
1
5
MODEL: EB313HG
USER MANUAL
2
3
1. SNOOZE / LIGHT button
2. Weather Forecast & Barometric Trend Area
3. Temperature & Humidity Area
4. Clock / Alarm Area
4
6
7
8
5
Moon Phase
6. ALARM: view alarm status; set alarm
7. MEM: view current, maximum and minimum
9
temperature / humidity readings
10
8. MODE: change display / settings
11
9.
and – : increase or decrease setting.
+
12
13
14
15
10. Strap hole
11.
12.
: turn alarm off for 24 hours
: Lock button
13. Table stand / Belt clip
14. Battery compartment
15. °C / °F switch
16. RESET hole
16
1
EB313HG_EN_final
1
1/11/05, 2:52 PM
SET ALARM
BAROMETRIC TREND
1. Press ALARM to switch to Alarm display.
DESCRIPTION
TREND
2. Press and hold ALARM again for 2 seconds. The
Alarm settings will blink.
Rising
3. Select the hour and minute. Press
or – to
+
change settings. Press ALARM to confirm.
Steady
Falling
ACTIVATE ALARM
Press to activate or deactivate the Alarm.
shows in the Clock / Alarm Area when the Alarm
is activated.
WEATHER FORECAST
SILENCE ALARM
This product forecasts the next 12 to 24 hours of weather
within a 19 - 31 mile (30 to 50 km) radius with 70 to
75 percent accuracy. The weather forecast is always
displayed.
When the Alarm time is reached, the alarm will sound
for 2 minutes. Press SNOOZE / LIGHT to silence it for 8
minutes. Or, press
to turn it off until the next day.
PARTLY
CLOUDY
SEVERE
If no button is pressed, the Alarm will automatically
silence after 2 minutes. It will then sound again after
8 minutes.
CLOUDY
RAINY
CLEAR
WEATHER
BAROMETER
This product tracks barometric pressure changes over
the past 24 hours to provide the weather forecast
and a trend line showing the direction of barometric
change.
3
EB313HG_EN_final
3
1/11/05, 2:52 PM
TEMPERATURE AND HUMIDITY
BACKLIGHT
This product can display current, minimum, and
maximum temperatures and humidity percentage
information.
Press SNOOZE / LIGHT to activate the backlight.
KEY LOCK
SELECT TEMPERATURE UNIT
The buttons may be locked to avoid accidental changes.
To activate lock, press and hold
seconds. Repeat the same procedure to unlock buttons.
Slide the °C / °F switch into the desired location. The
switch is located inside battery compartment.
LOCK for two
MINIMUM / MAXIMUM RECORDS
SPECIFICATIONS
TEMPERATURE
Press MEM to toggle between current, maximum (MAX)
and minimum (MIN) records. To clear the records, press
and hold MEM for 2 seconds. A beep will sound to confirm
that the memory has been cleared.
Unit
°C or °F
Temperature Range
-4.0 °F to +14.0 °F-
(-20.0 °C to +60.0 °C)
MOON PHASE
Resolution
0.2° F (0.1 °C)
The Calendar must be set for this feature to work.
Press
or – to view the moon phase for the
RELATIVE HUMIDITY
Range
+
next or previous day. Press and hold or – to scan
quickly through the years (2001 to 2099).
+
25% to 95%
1%
Resolution
New Moon
Waxing crescent
First quarter
Full Moon
Waning gibbous
Last quarter
Waxing gibbous
Waning crescent
4
EB313HG_EN_final
4
1/11/05, 2:52 PM
BAROMETER
ABOUT OREGON SCIENTIFIC
Weather Forcast
Rainy, cloudy, partly
cloudy, sunny, severe
weather
more about Oregon Scientific products such as digital
cameras; MP3 players; children's electronic learning
products and games; projection clocks; health and
fitness gear; weather stations; and digital and
conference phones. The website also includes contact
information for our customer care department in case
you need to reach us, as well as frequently asked
questions and customer downloads.We hope you will
find all the information you need on our website, however
if you'd like to contact the Oregon Scientific Customer
Care department directly, please visit:
NOTE
Suggested operating temperature for a more
accurate weather forecast: 32 °F to +140 °F
(0 °C to +60 °C )
CLOCK
Clock display
Hour format
Time zone
HH:MM:SS
12hr AM/PM
PA (Pacific), MO
(Mountain), CE (Central)
www2.oregonscientific.com/service/support
or EA (Eastern)
OR
Calendar
Alarm
MM/DD; weekday in
5 languages (E, D, F, I, S)
Call 949-608-2848 in the US.
2- minute single alarm
For international enquiries, please visit:
default.asp
POWER
Main unit batteries
2 x CR2032 Lithium
batteries
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
5
EB313HG_EN_final
5
1/11/05, 2:52 PM
WARNING Changes or modifications to this unit not
expressly approved by the party responsible for
compliance could void the user's authority to operate
the equipment.
DECLARATION OF CONFORMITY
The information below is not to be used as contact for
support or sales. Please call our customer service
com, or on the warranty card for this product) for all
inquiries instead.
NOTE This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications.However, there is
no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
We
Name:
Oregon Scientific, Inc.
19861 SW 95th Place,
Tualatin, Oregon 97062 USA
1-800-853-8883
Address:
Telephone No.:
Fax No.:
1-503-684-3332
declare that the product
Product No.:
EB313HG
Product Name:
Manufacturer:
Address:
Remote Thermometer
IDT Technology Limited
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.
Block C, 9/F, Kaiser Estate,
Phase 1, 41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
•
•
6
EB313HG_EN_final
6
1/11/05, 2:52 PM
is in conformity with Part 15 of the FCC Rules. Operation
is subject to the following two conditions:
1)This device may not cause harmful interference.
2)This device must accept any interference received,
including interference that may cause undesired
operation.
CAUTION
—
—
The content of this manual is subject to change
without further notice.
Due to printing limitations, the displays shown
in this manual may differ from the actual display.
—
The contents of this manual may not be
reproduced without the permission of the
manufacturer.
7
EB313HG_EN_final
7
1/11/05, 2:52 PM
Handheld Weather Forecaster
Model: EB313HG
User Manual
EB313HG_EN_final
8
1/11/05, 2:52 PM
© 2005 Oregon Scientific. All Rights Reserved.
086-003462-063
EB313HG_EN_final
9
1/11/05, 2:52 PM
|