Atmor new35 User Manual

1
2
3
4
5
7
L
INSTANT  
WATER HEATER  
230V  
N
E
P
8
4
6
7
7
1
2
3
5
L
230V  
N
P
E
6
8
7
7
1
2
3
4
5
L2  
L1 400V  
230V  
N
P
E
1. Multi-pole switch  
2. Terminal block  
3. Thermostat  
5. Switches  
6. LED Light  
7. Heating elements  
8. Pressure switch  
8
6
7
4. Microswitch  
Table 2  
kW loading  
220V 230V 240V  
3.0 3.3 3.6  
3.2 3.5 3.8  
5.0 5.5 6.0  
5.5 6.0 6.6  
7.0 7.7 8.3  
7.3 8.0 8.7  
8.7 9.5 10.3  
Recommended  
cable size  
Recommended  
fuse rating  
Model  
Heat Setting  
New/Lotus - 3.0  
New/Lotus - 3.5  
New/Lotus - 5.0  
New/Lotus - 5.5  
New/Lotus - 7.0  
New/Lotus - 8.0  
New/Lotus - 9.5  
1.0;2.0 or 3.0kW  
1.5;2.0 or 3.5kW  
2.0;3.0 or 5.0kW  
2.5;3.0 or 5.5kW  
3.0;4.0 or 7.0kW  
4.0;4.0 or 8.0kW  
4.5;5.0 or 9.5kW  
2.5mm2  
2.5/4mm2  
4/6mm2  
4/6mm2  
6/10mm2  
6/10mm2  
10mm2  
16amps  
20amps  
25amps  
25-32amps  
40amps  
40amps  
45amps  
• Operating water pressure 0.3-7 BAR (5-100 psi) Water pressure operating power switch  
• Standard 1/2"Ø compression inlet connection Top-left and right cable entry • Bottom-left water entry  
Installation Instructions  
UNIT DIMENSIONS: HEIGHT 185mm WIDTH 300mm DEPTH 110mm  

Whirlpool ELECTRIC LG5796XM User Manual
Uniden DMX 778 Series User Manual
Toshiba Computer Drive MK2565GSX User Manual
Sharp MD MT80H User Manual
Seagate Pipeline HD ST3500312CS User Manual
SanDisk SDUFD2AB 4096 User Manual
Rhino Mounts RHINO TW144 User Manual
Research In Motion Blackberry Cell Phone 8530 User Manual
Pioneer Premier DEH P630 User Manual
Panasonic SQ TC512F User Manual