INSTRUCTION MANUAL
5
Atomic time - WWVB Radio Controlled Time
Function keys
5
6
LCD Screen
6
7
Contents
Manual Settings
Changing the display mode
Alarm
Weather Forecast and Tendency
Outdoor transmitter
915 MHz Reception
Mounting
Care and maintenance
Specifications
Warranty
10
10
11
14
14
14
15
16
17
Language
Page
__________________________________________________________________
English
French
Spanish
1
INSTANT TRANSMISSION is the state-of-the-
art new wireless transmission technology,
exclusively designed and developed by LA
CROSSE TECHNOLOGY. INSTANT
This product offers:
TRANSMISSION offers you an immediate
update (every 4 seconds!) of all your outdoor
data measured from the transmitters: follow
your climatic variations in real-time!
1
2
FEATURES:
RADIO-CONTROLLED CLOCK:
ALKALINE BATTERIES ARE RECOMMENDED FOR USE IN BOTH UNITS. AVOID USING
RECHARGEABLE BATTERIES.
Hanging holes
TO INSTALL / REPLACE BATTERIES IN THE TEMPERATURE TRANSMITTER
(INSTALL BATTERIES IN TRANSMITTER BEFORE INSTALLING BATTERIES IN RADIO-
CONTROLLED CLOCK)
The transmitter uses 2 x AA,1.5V batteries. To install and replace the batteries, please follow
the steps below:
LCD1
display
Function keys
Battery cover
LCD2
display
1.
2.
3.
Remove the battery cover by pushing down towards bottom of transmitter and sliding
cover out.
Insert the batteries, observing the correct polarity (see marking inside battery
compartment).
Replace the battery cover on the unit.
Foldable stands
WWVB Radio controlled time with manual time setting
Time display: hour, minute, second
Alarm setting with snooze function
Calendar display
TO INSTALL / REPLACE BATTERIES IN THE RADIO-CONTROLLED CLOCK
The radio-controlled clock uses 2 x AA,1.5V batteries. To install and replace the batteries,
please follow the steps below:
Weekday display (3 languages to choose from: English, Spanish, French,)
Time zone setting
Daylight savings time ON/OFF option (DST)
Indoor and outdoor temperature display
Temperature display in ºF/ ºC selectable
Weather forecast with weather tendency indicator based on air pressure
Wireless transmission at 915MHz
1.
Insert finger or other solid object in the space at the bottom center of the battery
compartment and lift up to remove the cover.
Insert batteries observing the correct polarity (see marking inside battery compartment).
2.
3.
Replace compartment cover.
Signal reception intervals at 4 seconds
Low battery indicator
Wall mount or freestanding
DO NOT SET THE CLOCK.
REPLACING BATTERY(S):
For best performance, batteries should be replaced at least once a year to maintain the best
running accuracy. Ensure that the batteries used are new and the correct size.
OUTDOOR TEMPERATURE TRANSMITTER:
Please help in the preservation of the environment and return used batteries
to an authorized depot.
Remote transmission of outdoor temperature to the
radio-controlled clock by 915 MHz signals
Wall mounting case
Holder
3
4
3.
4.
Now the minute digits will start flashing.
Set the desired minutes by pressing and releasing the + key. If the + key is held, the units
will increase by 5.
2.
Press and release the SET key to enter the mode “ºC or ºF Temperature Setting”.
°C OR °F TEMPERATURE
1.
2.
The characters “°F” or “°C” will start flashing on LCD2 (Default setting °F). By use of the
+ key select “°C” for temperature display in degrees Celsius or “°F” for degrees
Fahrenheit.
Press and release the SET key to exit the setting mode and switch back to the normal
display mode.
5.
Press and release the SET key to move to the “Year Setting”.
Note: The unit will still try to receive the signal every day despite it being manually set. When it
does receive the signal, it will change the manually set time into the received time. During
reception attempts the WWVB tower icon will flash. If reception has been unsuccessful, then
the WWVB tower icon will not appear but reception will still be attempted the following hour.
WWVB time reception takes place from 12:00 am through 6:00 am each day (attempts WWVB
reception every full hour within this time frame). When the time signal is received for example at
1:00 am, the radio-controlled clock will not attempt to receive the WWVB signal for the
remaining hours until 6:00 am. Therefore, the next signal attempt will take place between 12:00
am and 6:00 am the next day. The other times WWVB reception takes place, are upon setup
and after manual time set exiting mode. Reception is generally not possible during daylight
hours due to the interference of the sun.
EXIT THE MANUAL SETTING MODES
To return to the normal display mode from anywhere in manual setting mode simply press
the SNZ key anytime.
If no keys are pressed for at least 15 seconds in setting mode, the radio-controlled clock
will automatically switch back to normal display mode.
CHANGING THE DISPLAY MODE (DAY, ALARM AND SECONDS)
There are 3 possible display modes to view the day, alarm and seconds.
The indoor temperature/outdoor temperature/month&date/weekday are the default.
To change the display:
YEAR
The year can be selected sequentially from 2001 to 2029 and will then start over again (default
setting 2006). The year will only appear in the manual setting mode.
1.
2.
The year digits will start flashing on LCD2. Select the desired year by use of the + key.
Press and release the SET key to switch to the “Month Setting”.
1.
2.
3.
Press the + key. The display should now show the indoor temperature/ outdoor
temperature/ alarm/ weekday.
Press the + key a second time and the display will now show the indoor temperature/
outdoor temperature/ seconds/ weekday.
MONTH
1.
2.
The month digits on LCD2 will start flashing. Set the desired month by use of the + key.
Press and release the SET key to move to the mode “Date Setting”.
Press the + key a third time and the display will return to the normal display.
DATE
ALARM
1.
The digits for the date will start flashing on LCD2 (Default setting 1). Set the desired date
To enter into the alarm setting mode:
by use of the + key.
1.
2.
3.
4.
5.
Hold the ALM key for 4 seconds. The hour digits start flashing.
Press and release the + key to set the hour.
Press and release the ALM key to set the minutes. The minute digits start flashing.
Press and release the + key to set the minutes.
Press and release again the ALM key to exit the Alarm setting mode or wait for 15
seconds automatic timeout.
Note: The date can only be set in conjunction with the selected month. For example, it is
not possible to set the date 30 if the month of February is selected.
Press and release the SET key to move to “Weekday”.
2.
WEEKDAY
1. The weekday symbols will be displayed on LCD2 in the pre-set language and flashing.
Set the desired weekday by use of the + key.
9
10
TO DEACTIVATE THE ALARM:
The weather icons change when the unit detects a change in air pressure. The icons change in
order, from “sunny” to “partly sunny” to “cloudy” or the reverse. It will not change from “sunny”
directly to “rainy”, although it is possible for the change to occur quickly. If the symbols do not
change then the weather has not changed, or the change has been slow and gradual.
Alarm icon ((())) (ON)
Weather Tendency Arrows
The alarm will be automatically ON when the alarm time is set. To deactivate the alarm (OFF),
press and release once the ALM key in normal mode display. The alarm icon will disappear, the
alarm is now off.
Other possible displays in LCD 2 are 2 weather tendency arrows, one that points up (on the left
side of the forecast) and one that points down (on the right side of the forecast). These arrows
reflect current changes in the air pressure. An arrow pointing up indicates that the air pressure
is increasing and the weather is expected to improve or remain good. An arrow pointing down
indicates that the air pressure is decreasing and the weather is expected to become worse or
remain poor. No arrow means the pressure is stable.
SNOOZE SETTING
The snooze can only be activated during alarm time for a snooze duration of 10 minutes by
pressing the SNZ key on the back of the clock.
OUTDOOR TEMPERATURE TRANSMITTER:
WEATHER FORECAST
The temperature is measured and transmitted to the radio-controlled clock every 4 seconds.
The radio-controlled clock will update the temperature display every 20 seconds.
The range of the outdoor temperature transmitter may be affected by the temperature. At cold
temperatures the transmitting distance may be decreased. Please bear this in mind when
positioning the transmitter. Also the batteries may be reduced in power during periods of
extreme cold temperatures.
The weather forecasting feature is estimated to be 75% accurate. The weather forecast is
based solely upon the change of air pressure over time. In areas where the weather is not
affected by the change of air pressure, this feature will be less accurate.
Weather Icons
There are 3 possible weather icons that will be displayed in the LCD 2:
915MHz RECEPTION CHECK FOR OUTDOOR TEMPERATURE TRANSMITTER
The radio-controlled clock will receive the temperature data within 4 seconds. If the temperature
data is not being received 2 minutes after setting up (or the display shows “- - -”), then please
check the following points:
1.
The distance of the radio-controlled clock or outdoor temperature transmitter should be at
least 6 feet (2 meters) away from any interfering sources such as computer monitors or
TV sets.
Sunny—indicates that the weather is expected to improve (not that the weather will be sunny).
2.
3.
Avoid placing the receiver onto or in the immediate proximity of metal window frames.
Using other electrical products such as headphones or speakers operating on the same
signal frequency (915MHz) may prevent correct signal transmission and reception.
Neighbors using electrical devices operating on the 915MHz signal frequency can also
cause interference.
Sun with Clouds—indicates that the weather is expected to be fair (not that the weather will be
sunny with clouds).
4.
Clouds with Rain—indicates that the weather is expected to get worse (not that the weather
will be rainy).
11
12
Note: When the 915 MHz signal is received correctly, do not re-open the battery cover of either
the outdoor temperature transmitter or radio-controlled clock, as the batteries may spring free
from the contacts and force a false reset. Should this happen accidentally then reset all units
(see Setting-up above) otherwise transmission problems may occur.
FOLDOUT TABLE STAND
The foldout table stands legs are located on the backside. Unfold the stands out,
below the battery compartment. Once the foldout table stands are extended, place
the radio-controlled clock in an appropriate location.
The maximum transmission range is 330 feet (100 meters) from the outdoor temperature
transmitter to the radio-controlled clock (in open space). However, this depends on the
surrounding environment and interference levels. If no reception is possible despite the
observation of these factors, all system units have to be reset (see Setting-up).
WALL MOUNTING
1)Using a straightedge, horizontally space at 3.93“ (100 mm) three screw
positions on a wall.
Note: In case the radio-controlled clock is not able to detect the WWVB-signal (disturbances,
transmitting distance, etc.), the time can be manually set (please refer to notes on Manual time
setting).
2)
Install three mounting screws (not included) into a wall within transmission
range—leaving approximately 3/16 of an inch (5mm) extended from the wall.
Place the radio-controlled clock onto the screws, using the hanging holes on
the backside. Gently pull the radio-controlled clock down to lock the screws
into place.
3)
POSITIONING
Before permanently mounting, ensure that the radio-controlled clock is able to receive WWVB
signals from the desired location. Also, extreme and sudden changes in temperature will
decrease the accuracy of the radio-controlled clock, and changes in elevation will result with
inaccurate temperatures readings for the next 12 to 24 hours. These changes will require a 12
to 24 hour wait before obtaining reliable data.
Note: Always ensure that the radio-controlled clock locks onto the screws before releasing.
POSITIONING THE OUTDOOR TEMPERATURE TRANSMITTER
The outdoor temperature transmitter can be mounted with the use of screws:
MOUNTING WITH SCREWS
To achieve a true temperature reading, avoid mounting where direct sunlight can reach the
outdoor temperature transmitter. It is recommended to mount the outdoor temperature
transmitter on a North-facing wall or in any well shaded area. The maximum transmitting range
is 330 feet (100 meters) obstacles such as walls, concrete, and large metal objects can reduce
the range.
1)
2)
Remove the mounting bracket from the outdoor temperature transmitter.
Place the mounting bracket over the desired location. Through the two screw
holes of the bracket, mark the mounting surface with a pencil.
Where marked, start the screw holes into mounting surface.
Screw mounting bracket onto the mounting surface. Ensure that the screws are
flush with the bracket.
3)
4)
Place both units in their desired location, and wait approximately 10 minutes before
permanently mounting to ensure that there is proper reception. The outdoor temperature
transmitter is not waterproof and should not be placed anywhere it will become submerged in
water or be directly in the rain.
TROUBLESHOOTING:
Problem:
Solution:
Problem:
Solution:
The LCD is faint.
1) Replace the batteries.
No reception of WWVB signal
1) It may help reception to face the front of the radio-controlled clock in the
general direction of Ft. Collins, Colorado.
POSITIONING THE RADIO-CONTROLLED CLOCK:
There are two possible ways to mount the radio-controlled clock:
use of the foldout table stands
wall mounting
13
14
2) Wait overnight for signal.
Avoid areas where the units can be exposed to sudden changes in temperature, i.e. direct
sunlight, extreme cold and wet/moist conditions as these will lead to rapid changes which
reduce the accuracy of readings.
When cleaning the LCD and casing, use a soft damp cloth only. Do not use solvents or
scouring agents.
3) Be sure the radio-controlled clock is at least 6 feet (2 meters) from any
electrical devices, i.e. TV sets, computers, or other radio controlled clocks.
4) Remove batteries for five minutes, reinsert and leave the unit alone
overnight without pressing any keys.
Problem:
Solution:
Problem:
Solution:
Hour is incorrect (minute and date are correct).
Do not submerge the units into water.
Immediately remove all low powered batteries to avoid leakage and damage. Replace
only with new batteries of the recommended size.
Do not make any repairs to the units. Please return it to the original point of purchase.
Opening and tampering with the units may invalidate the warranty.
1) Be sure the correct time zone and daylight saving time is selected.
"OF“ appears in the indoor temperature section of the LCD
1) Move the radio-controlled clock to an area with warmer or cooler
surrounding temperature. Current surrounding temperatures are outside
measuring range.
2) Replace Batteries.
SPECIFICATIONS:
Problem:
Solution:
"--.-" appears in the outdoor temperature section of the LCD.
1) Remove the batteries of both units for ten minutes, Press any button 20
times with battery out then reinsert them again. Make sure the batteries are
new and fresh.
2) Move the radio-controlled clock closer to the transmitter or place the
transmitter closer to the radio-controlled clock. Make sure the clock is at a
receivable range from the transmitter.
3) Move the units to another location. Interferences from other electrical
devices operating on the same signal frequency (915MHz) may prevent
correct signal transmission and reception.
Temperature measuring range
Indoor
:
14.0F to 99.5F with 0.5F resolution
(-9.5C to +38.0C with 0.5C resolution)
(“OF” displayed if outside this range)
Outdoor
:
-39.0F to 140.0F with 0.5F resolution
(-39.5C to 60.0C with 0.5C resolution)
(“OF” displayed if outside this range)
Temperature checking interval
Indoor
Outdoor
:
:
Every 20 seconds
Every 4 seconds
Problem:
Solution:
"OF“ appears in the outdoor temperature section of the LCD.
1) Wait until the current surrounding temperature cools down or increases.
Current temperature is outside of the measuring range of the transmitter.
The outdoor temperature will be displayed again once the current
surrounding temperature is within the range of the transmitter.
2) Replace Batteries
Transmission distance
Maximum 330 feet (100 meters) in open field, depending upon surrounding structures,
mounting location and possible interfering sources.
Power source (Alkaline batteries recommended)
Radio-controlled clock
Transmitter
Battery life
:
:
:
2 x AA, 1.5V batteries
2 x AA, 1.5V batteries
about 24 months
CARE AND MAINTENANCE:
Avoid placing the units in areas prone to vibration and shock as these may cause
damage.
Dimensions (H x L x W)
Radio-controlled clock
:
8.03“ x 12.20“ x 1.18“ / 204 x 310 x 30mm
16
15
center; (6) units used for other than home use (7) applications and uses that this product was not intended or
(8) the products inability to receive a signal due to any source of interference.
Transmitter
:
5.05” x 1.50” x 0.83” / 128.3 x 38.2 x 21.2 mm
Low battery indicator:
-RX Low battery indicator is displayed on the LCD when the weather station batteries require
changing.
This warranty covers only actual defects within the product itself, and does not cover the cost of installation or
removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller
or performance variations resulting from installation-related circumstances.
-TX Low battery indicator is displayed on the LCD when the transmitter batteries require
changing.
LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL,
PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF
THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC
INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S REACH.
Alarm :
- 4 digits showing alarm hour and alarm minute.
- 85 seconds duration approx.
- Snooze duration is 10 minutes.
This warranty gives you specific legal rights. You may also have other rights specific to your State. Some
States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of
limitation may not apply to you.
For warranty work, technical support, or information contact:
WARRANTY INFORMATION
La Crosse Technology
2809 Losey Blvd. S.
La Crosse, WI 54601
Phone: 608.782.1610
Fax: 608.796.1020
La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in
materials and workmanship.
This limited warranty begins on the original date of purchase, is valid only on products purchased and used in
North America and only to the original purchaser of this product. To receive warranty service, the purchaser
must contact La Crosse Technology, Ltd for problem determination and service procedures. Warranty service
can only be performed by a La Crosse Technology, Ltd authorized service center. The original dated bill of sale
must be presented upon request as proof of purchase to La Crosse Technology, Ltd or La Crosse Technology,
Ltd’s authorized service center.
e-mail: [email protected] (warranty work)
La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated
herein, with new or reconditioned parts or products if found to be defective during the limited warranty period
specified above. All replaced parts and products become the property of La Crosse Technology, Ltd and must
be returned to La Crosse Technology, Ltd.
Questions? Instructions? Please visit: www.lacrossetechnology.com/8158
All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or
processed using electronic, mechanical or chemical procedures without written permission of the publisher.
Replacement parts and products assume the remaining original warranty, or ninety (90) days, whichever is
longer. La Crosse Technology, Ltd will pay all expenses for labor and materials for all repairs covered by this
warranty. If necessary repairs are not covered by this warranty, or if a product is examined which is not in need
or repair, you will be charged for the repairs or examination.
This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked
and corrections made in the next issue. We accept no liability for technical mistakes or printing errors, or their
consequences.
The owner must pay any shipping charges incurred in getting your La Crosse Technology, Ltd product to a La
Crosse Technology, Ltd authorized service center.
All trademarks and patents are acknowledged.
Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with the following
specified exceptions: (1) damage caused by accident, unreasonable use or neglect (including the lack of
reasonable and necessary maintenance); (2) damage occurring during shipment (claims must be presented to
the carrier); (3) damage to, or deterioration of, any accessory or decorative surface; (4) damage resulting from
failure to follow instructions contained in your owner’s manual; (5) damage resulting from the performance of
repairs or alterations by someone other than an authorized La Crosse Technology, Ltd authorized service
17
18
|