KitchenAid KGSS907S User Manual

®
30" Freestanding and Slide-In Gas Range  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
Freestanding Range  
Slide-in Range  
KGRS807S  
KGSK901S  
KGSS907S  
B
A
Gas supply: Use 3/4" (1.9 cm) rigid pipe gas  
supply line to the range location. A smaller size  
pipe on long runs may result in insufficient gas  
supply. With L.P. gas, piping or tubing size can  
be 1/2" (1.3 cm) minimum. If local codes  
permit, it is recommended that new flexible  
metal tubing, design-certified by CSA, 4-5 feet  
(122-152.4 cm) long, 1/2" (1.3 cm) or 3/4"  
(1.9 cm) I.D., be used for connecting the range  
to the rigid gas supply line. A 1/2" (1.3 cm)  
male pipe thread is needed for connection to  
pressure regulator female pipe threads. An  
easily accessible individual manual shutoff  
valve must be located in the same room, but  
external to the range.  
A
F
C
B*  
D*  
C
E
D
E**  
F**  
A. 5³⁄₄" (14.6 cm)  
B. 30" (76.2 cm)  
E. Model/serial number plate  
(located on the right-hand  
side oven door trim)  
F. 27¹⁄₄" (69.2 cm) max. from  
handle to standoff at back  
of range**  
A. 30⁹⁄₁₆" (77.6 cm)  
D 30" (76.2 cm)  
B. 35⁵⁄₈" (90.5 cm) height to  
underside of cooktop edge  
with leveling legs screwed  
all the way in*  
C. Model/serial number plate  
(located on the right-hand  
side oven door trim)  
E. 27¼" (69.2 cm) from  
handle to standoff at  
back of range**  
F. 23" (58.4 cm) countertop  
notch to rear of cooktop  
Electrical: 120-volt, 60 Hz, AC-only, 15 amp,  
fused electrical circuit is required. A separate  
circuit is recommended. A time-delay fuse or  
circuit breaker is recommended.  
C. 41³⁄₄" (106 cm) overall height  
with leveling legs screwed all  
the way in.  
D. 36" (91.4 cm) cooktop trim  
height with leveling legs  
screwed all the way in*  
*Range can be raised approximately 1" (2.5 cm) by adjusting  
the leveling legs.  
*Range can be raised approximately 1" (2.5 cm) by adjusting  
the leveling legs.  
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)  
countertop; front of oven door protrudes 1" (2.5 cm) beyond  
24" (61 cm) base cabinet.  
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)  
countertop; front of oven door protrudes 1³⁄₄" (4.4 cm) beyond  
24" (61 cm) base cabinet.  
SLIDE-IN RANGE COUNTERTOP PREPARATION  
The cooktop sides of the slide-in range fit over  
the cutout edge of your countertop.  
3/8" (1.0 cm) from each front corner and/or  
rounded edge flattened.  
30"  
(76.2 cm)  
If you have a square finish (flat) countertop  
and the opening width is 30" (76.2 cm), no  
countertop preparation is required.  
If countertop opening width is greater than  
30" (76.2 cm), adjust the 3/8" (1.0 cm)  
dimension.  
³⁄₈"  
(1.0 cm)  
Formed front-edged countertops must have  
molded edge shaved flat 3/8" (1.0 cm) from  
each front corner of opening.  
Countertop must be level. Place level on  
countertop, first side to side; then front to  
back. If countertop is not level, range will not  
be level. Range must be level for satisfactory  
baking conditions.  
30 ³⁄₄"  
(78.1 cm)  
Tile countertops may need trim cut back  
CABINET OPENING DIMENSIONS  
NOTE: 24" (61 cm) minimum  
when bottom of wood or  
metal cabinet is protected by  
not less than 1/4" (0.64 cm)  
flame retardant millboard  
covered with not less than  
No. 28 MSG sheet steel,  
0.015" (0.4 mm) stainless  
steel, 0.024" (0.6 mm)  
For minimum  
clearance to top  
of the cooktop,  
see NOTE.  
For minimum  
clearance to top  
of the cooktop,  
see NOTE.  
13" (33 cm) upper  
cabinet depth  
13" (33 cm) max.  
upper cabinet depth  
30" (76.2 cm) min.  
opening width  
30" (76.2 cm) min.  
opening width  
22¹⁵⁄₁₆" (58.3 cm)  
opening depth  
18" (45.7 cm)  
upper cabinet  
to countertop  
18" (45.7 cm)  
¾" (1.9 cm)  
radius both corners  
30" (76.2 cm)  
upper cabinet  
aluminum or  
min. opening  
to countertop  
width  
0.020" (0.5 mm) copper.  
30" (76.2 cm)  
min. opening  
width  
Grounded  
outlet  
30" (76.2 cm) minimum  
Grounded  
clearance between the top of  
the cooking platform and the  
bottom of an unprotected  
wood or metal cabinet.  
outlet  
This shaded area  
recommended for should not  
installation of  
outlet or  
Cabinet door  
or hinge  
Cabinet door  
or hinge  
should not  
extend into  
the cutout.  
8"  
This shaded area  
5" (12.7 cm) min.  
clearance from  
both sides of the  
range to the side  
wall or other  
8"  
(20.3 cm)  
recommended for  
installation of  
outlet or  
5" (12.7 cm) min.  
clearance from  
both sides of the  
range to the side  
wall or other  
(20.3 cm)  
extend into  
the cutout.  
8"  
8"  
(20.3 cm)  
junction box.  
(20.3 cm)  
junction box.  
combustible  
material.  
7" (17.8 cm)  
4¹⁄2  
(11.4 cm)  
"
If installing a range hood or  
microwave hood combination  
above the range, follow the  
range hood or microwave  
hood combination  
installation instructions for  
dimensional clearances  
above the cooktop surface.  
4¹⁄2"  
7" (17.8 cm)  
combustible  
material.  
(11.4 cm)  
This shaded area  
recommended for  
installation of  
Available area  
for gas and  
electric  
Available area  
for gas and electric  
installation.  
1¹⁄2  
"
1¹⁄2" (3.8 cm)  
(3.8 cm)  
rigid gas pipe.  
This shaded area  
recommended for  
installation of  
installation.  
4¹⁄2  
(11.4 cm)  
"
4¹⁄2  
(11.4 cm)  
"
rigid gas pipe.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10118262  
04-18-07  

Miele CVA 615 User Manual
Maxtor MaxAttach NAS 4000 Series User Manual
Krell Industries Evolution 505 User Manual
Kenwood KDC MP6090R User Manual
Kenwood DPF 1030 User Manual
JVC KW XC410 User Manual
GPX CI109PR User Manual
Emerson PD6513 User Manual
Black Box Computer Accessories IC188A User Manual
ABB CL3020 User Manual