hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Overview
The HP StorageWorks Modular SAN Array 1000 is a 2 Gb Fibre Channel storage system designed for the entry-
level to mid-range Storage Area Network (SAN). Designed to reduce the complexity, expense and risk of SAN
deployment, the msa1000 is a scaleable, high performance storage system built with investment protection in
mind. The modular design of the msa1000 allows the user to easily add storage capacity on an as needed basis.
HP StorageWorks Modular SAN
Array 1000
The msa1000 combines the array controller shelf and the drive shelf, which holds up to fourteen 1” universal disk
drives in a single 4U rackmount cabinet. More storage can be easily deployed with the addition of up to two
StorageWorks 4314 Enclosures for a maximum storage capacity of 6 TB when using the new 146 GB drives. The
msa1000 provides the latest 2 Gb Fibre Channel technology to the hosts. Besides the single port 2 Gb Fibre
Channel I/O module that comes standard, there is an optional 3-port 2 Gb Fibre Channel hub that also fits inside –
an ideal low cost solution for simple 2-node clustering. There is also a newly introduced 8-port switch that mounts
internally, featuring a low cost per port option that saves rack space. The msa1000 provides Ultra3 SCSI
connections to the hard drives and uses the HP Universal 1” Ultra2, Ultra3, and/or Ultra320 drives. By utilizing
SCSI drives, the msa1000 lowers the total cost of ownership and extends the customer’s hardware investments
into the future.
An alternative firmware version, installed in place of the standard version, now enables support for OpenVMS and
Tru64 UNIX. A copy of this alternative firmware ships with the msa1000 and is also downloadable at no charge
from the HP msa1000 Web site. It replaces the existing firmware that ships with the MSA1000. Included with the
firmware will be instructions on the procedure to upgrade the firmware in either a Tru64 UNIX or an OpenVMS
environment
•
•
•
•
•
•
•
High performance controller(s) built on DAS to SAN {DtS} architecture for maximum investment protection
4U rackmount design combining both the controller and disk shelf
2 Gb Fibre Channel host connections
The msa1000 offers the following
key features
Ultra3 SCSI connections to drives
Support for HP Ultra2, Ultra3, and Ultra320 Universal 1” Drives
Scaleable from 3 to 42 drives via HP StorageWorks 4200/4300 Enclosures
Support for 1 Gb and 2 Gb Fibre Channel fabrics
•
•
•
•
•
•
Multiple clusters and/or single server access to an individual msa1000.
What’s new
Support for concurrent access by servers with OpenVMS and Tru64 UNIX operating systems
Redundancy (if present) retained while expanding number of drives or enlarging LUNs
New 3-port embedded hub or 8-port switch option
Ability to add an additional storage drive enclosure (42/4300) to a msa1000 without power cycling unit
Support for larger and/or faster drives allowing total capacity to scale to 6 TB
•
•
•
DS10, DS10L, DS20E, DS25
ES40, ES45, ES47, ES80
Supported Alpha servers
GS80, GS160, GS320, GS1280
DA-11621
Canada — Version 2 — April 15, 2003
1
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Models
HP StorageWorks Modular SAN
Array 1000 For Alpha Server
Systems w/ OpenVMS and Tru64
UNIX
msa1000, with 256MB cache
201723-B22/
3R-A4328-AA
218231-B22/
3R-A4330-AA
254786-B21/
3R-A3954-AA
218960-B21/
3R-A2969-AA
msa1000 Controller, with 256MB cache
256 MB Cache Module for Controller
msa Fibre Channel I/O Module
msa SAN Switch 2/8 (integrated)
288247-B21/
3R-A4289-AA
msa HUB 2/8 (integrated)
286763-B21/
3R-A3907-AA
FCA2354 Host Adapter (Open VMS/Tru64 UNIX)
2 Gb SFP SW Transceiver Kit
261329-B21/
DS-KGPSA-DA
221470-B21/
3R-A2973-AA
HP StorageWorks Enclosure Model 4314R
HP StorageWorks Dual bus Enclosure Model 4354R
190209-001/
DS-SL13R-AA
190211-001/
DS-SL13R-BA
DA-11621
Canada — Version 2 — April 15, 2003
3
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
MSA1000 Components
With the following components, your storage capacity and performance can be scaled to new levels
The 4U cabinet houses up to fourteen 1” Universal hot pluggable Ultra2, Ultra3, and/or Ultra320 drives. Each
Modular SAN Array 1000
msa1000 includes the following standard components: (1) msa1000 Controller, (1) msa Fibre Channel I/O Module
with a single SFP, dual hot pluggable fans/power supplies and power cables, (2) 3’ VHDCI to VHDCI SCSI cables
to connect expansion enclosures, documentation and a CD Kit containing firmware upgrade code for Tru64 and
OpenVMS and a support software CD.
The modular design of the msa1000 makes it possible to add redundant controllers, redundant single port Fibre
Channel I/O Modules, 3-port hub, or msa SAN switch 2/8 and storage expansion enclosures.
The msa1000 Controller is an integrated RAID controller with an integrated LCD/LED status display and 256 MB
read/write battery-backed cache (expandable to 512 MB per controller). One msa1000 Controller is included with
the msa1000; a redundant msa1000Controller is an option.
msa1000 Controller
•
•
•
•
•
•
•
•
Redundant controller support with mirrored cache
Fabric, Private Loop & Public Loop Support
Auto Negotiated F, FL & L Port Login
RAID 0, 1, 1+0, 5 and ADG
Key Features
2 Gb/1 Gb Frequency Agile
Primary & Secondary Inter-Controller Link (ICL)
configurable with Command Line Interface (CLI)
Online RAID Level Migration: allows for online post-configuration change to
RAID level without destroying data or volume information.
msa1000 Controller
Management Features
•
•
Online Capacity Expansion: lets you add storage to an operational
msa1000—reducing expensive server downtime.
Global Online Spare: reduces the risk of data loss by facilitating automatic
rebuilds after a drive failure
Several fault tolerant configurations, which keep data available and servers
running while drives are being replaced, are supported including:
Fault Tolerance
•
Advanced Data Guarding (RAID ADG): Allocates the equivalence of two
parity drives across multiple drives and allows simultaneous write
operations.
•
•
Distributed Data Guarding (RAID 5): Allocates parity data across multiple
drives and allows simultaneous write operations.
Drive Mirroring (RAID 1, (1+0 Striped Mirroring)): Allocates half of the drive
array to data and the other half to mirrored data, providing two copies of
every file.
•
•
Minimizes downtime, reconstructs data, and facilitates a quick recovery
from drive failure
Fault Recovery
Online Spares: If a failure occurs, recovery begins with an online spare and
data is reconstructed automatically. Multiple online spares can be
assigned per array and used across multiple arrays. It is also possible to
assign different online spares across different arrays.
•
Array Accelerator: Onboard, battery-backed cache memory protects data in
the event of a power failure. In the unlikely event of a controller failure, the
battery-backed cache will save critical user data for up to three days
Provides a single 2 Gb Fibre Channel connection per controller from the host side into the msa1000. The msa
Fibre Channel I/O Module includes one 2 Gb, Short Wave, Small-Form-Factor-Pluggable Transceiver (SFP). A
second msa Fibre Channel I/O Module can be installed for redundancy when a redundant controller is used.
msa Fibre Channel I/O Module
DA-11621
Canada — Version 2 — April 15, 2003
4
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
MSA1000 Components
The HP StorageWorks msa Hub 2/3 is a low-cost interconnect designed for clustering or low cost, high speed
attachment of two servers to the msa1000, an entry-level storage area network (SAN) solution. The msa Hub 2/3
is a 3-port Fibre Channel Arbitrated Loop hub that is mounted on a blade that easily installs inside the msa1000
storage unit, saving valuable rack space. Two of these hubs may be installed for redundancy within the msa1000.
The msa Hub 2/3 is not cascadable.
msa Hub 2/3
The hub presents the user with two SFP ports for simple direct attachment to two single or clustered servers
without having to purchase an external interconnect device. It offers the most cost-effective solution for a user to
enable a clustered server environment.
•
high-performance: supports msa1000 with a 2 Gb interconnect capable of 200 MB/s speed
low cost: supports the entry-level SAN array with the most cost effective option for 2-node clustering
compact: imbeds in the msa1000, replacing the I/O module, saving valuable rack space
complete: comes with two SW SFPs – no need for further investment
•
•
•
The hp StorageWorks msa SAN switch 2/8 ia a new optional switch embedded on a blade, for mounting internal
to an msa1000. The msa SAN Switch 2/8 offers low price per port and full scalability, doing so while taking zero
rack space, even in a redundant configuration. It ships with four SFPs installed. Because of its’ low cost per port it
is the most cost effective method of enabling the larger SAN. It is interoperable with the hp line of SAN
interconnect family of FC switches.
msa SAN switch 2/8
•
•
•
•
•
eight 2 Gb ports: 1 to controller, 7 user accessible
product ships with 4 SFPs installed
no E-port restriction, accepts all optional software
interoperates with external SAN Switch 2 Gb switches
configuration and management methodology common with SAN Switch product line, same methods as
installed base of 30,000+ HP SAN Switches
2 Gb Small-Form-Factor-Pluggable (SFP) SW Transceivers are industry standard connection devices, which hot
plug into 2 Gb infrastructure components such as 2 Gb Fabric Switches. StorageWorks 2 Gb SFP SW
Transceivers support distances up to 300 metres at 2 Gb and 500 metres at 1 Gb using multi-mode fiber optic
cable.
2 Gb Small Form Factor Pluggable
(SFP) SW Transceiver Kit
Multi-Mode Fibre Channel cables provide a thin, flexible cabling solution that is immune to electromagnetic
interference. HP offers cables to connect the msa1000 to both 2 Gb and 1 Gb Fibre Channel infrastructures. LC
to LC cables are used when connecting the msa1000 to other 2 Gb Fibre Channel components because both
connections will utilize small form factor transceivers. LC to SC cables are used when connecting the msa1000 to
1 Gb Fibre Channel components. 1 Gb components use the larger GBIC style transceivers.
Multi-Mode Fibre Channel Cables
SOFTWARE COMPONENTS
The command line interface (CLI) is used to configure and manage the MSA1000. Additionally, the CLI can be
used to display system information and status. See the HP StorageWorks Modular SAN Array 1000 User Guide
for more information on the CLI commands
Command Line Interface (CLI)
•
•
•
•
•
Tru64 UNIX v5.1A with PK4 and NHD6
Tru64 UNIX v5.1B with IPK
OS Support
Tru64 UNIX Support
OpenVMS Support
OpenVMS v7.3-1 with TIMA (ECO) Kit
OpenVMS v7.2-2 with TIMA (ECO) Kit
OpenVMS v7.3 with TIMA (ECO) Kit
DA-11621
Canada — Version 2 — April 15, 2003
5
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Service & Support, CarePaq and Warranty Information
The Storage Services Packaging takes the existing storage product along with the existing services and creates a
Storage Service Packages
package of the storage hardware and appropriate services. The increased level of support provides for a higher
level of storage system availability for the customer. The package includes 24x7 support with a 4-hour response
for 3 years as well as installation and startup service.
Three-year Limited Warranty for msa1000s, Fibre Channel Cables and SFP Transceivers; 3 years parts
exchange; 1 year labour; 1 year on-site; next business day response. Options for the msa1000 carry their own
warranty. Refer to HP's Limited Warranty Statement for further details.
Warranty
Software Product Services
Hardware Product Services
•
•
HP warrants only that the Software media will be free of physical defects
for a period of ninety (90) days from delivery.
Service & Support, CarePaq and
Warranty Information
Upgrades to the 90 day media defect warranty are available as CarePaq
services. These services are available to upgrade the warranty to (1 or 3)
full year of 9 hours by 5 days (or 24x7) software advisory and remedial
software telephone support, new version license rights, and media and
documentation distribution service.
•
•
•
•
•
•
Installation services
On-site maintenance (includes warranty support)
Response time upgrades during the warranty period
Post-warranty coverage
RAID setup and performance consulting via statement of work
Migration service consulting via statement of work
Installation and Startup
Services
The Installation and Startup Service package provides installation and
configuration of HP StorageWorks products. Major categories of work could
include:
•
•
•
•
•
•
Pre-installation consulting and planning
Hardware installation, configuration and verification
RAID array configuration and initialization
Installation, configuration and verification of StorageWorks software
Service tools installed, configured and verified
Customer orientation
Warranty Upgrade Options
•
•
•
Response – Upgrade on-site response from next business day to same
day 4 hours
Coverage – Extend hours of coverage from 9 hours x 5 days to 24 hours x
7 days
Duration – Select duration of coverage for a period of 1, 3, or 5 years
DA-11621
Canada — Version 2 — April 15, 2003
6
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Service & Support, CarePaq and Warranty Information
9x5, Next Business Day, On-Site Coverage, 3 years
9x5, 4-Hour Response, On-Site Coverage, 3 years
24x7, 4-Hour Response, On-Site Coverage, 3 years
9x5, Next Business Day, On-Site Coverage, 5 years
9x5, 4-Hour Response, On-Site Coverage, 5 years
24x7, 4-Hour Response, On-Site Coverage, 5 years
Hardware Installation
FM-FCXHW-36
103840-002
FM-FC4HR-36
402165-002
FM-FC724-36
402164-002
FM-FCXHW-60
170183-002
FM-FC4HR-60
170185-002
FM-FC724-60
170187-002
FM-FCINS-IN
402162-002
CarePaq Information
Sample part numbers:
•
CarePaq is defined as an upgrade to the product warranty attribute, available for a specific duration and
hours of coverage.
•
•
CarePaq is not available for less than the product’s warranty duration.
CarePaq is available for sale anytime during the warranty period for most products, but the commencement
date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase
may be required.
•
CarePaq services are prepaid.
NOTE: For additional CarePaq (hardware & software) information, as well as orderable part numbers, please
refer to the URL listed below:
DA-11621
Canada — Version 2 — April 15, 2003
7
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Configuration Information
STEP 1 – ORDER REQUIRED ITEMS
HP StorageWorks Modular SAN Array 1000
201723-B22
Includes
•
•
•
•
•
•
•
(1) msa1000 Controller with 256 MB cache
(1) MSA Fibre Channel I/O Module with 2 Gb SFP SW Transceiver
Redundant Hot Pluggable Power Supply/blower assemblies
Universal Rackmounting Kit
msa1000 Support CD & Documentation
(2) Power cables
(2) 3-ft VHDCI to VHDCI SCSI cables
NOTE: Fibre Channel cables are ordered separately.
DA-11621
Canada — Version 2 — April 15, 2003
8
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Configuration Information
STEP 2 – SELECT OPTIONAL NON-REDUNDANT MSA1000 SYSTEM OPTIONS
msa SAN Switch 2/8 (integrated) (Includes four 2Gb SFPs)
288247-B21
286763-B21
msa Hub 2/3 (integrated) (Includes two 2 Gb SFP transceivers)
NOTE: The msa Hub 2/3 has two external Fibre Channel ports, both of which already
have 2 Gb transceivers installed. The msa SAN switch 2/8 has seven external
ports, four of which have transceivers installed.
DA-11621
Canada — Version 2 — April 15, 2003
9
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Configuration Information
STEP 3 – CHOOS E REDUNDANT MSA1000 SYSTEM OPTIONS
Redundant Configuration
msa1000 Controller
218231-B22
NOTE: Redundant configurations require two Host Adapters per server, an additional
controller for each server. Mixing of the msa Fibre Channel I/O Modular and the
msa Hub 2/3 is not supported. When configuring the msa1000 for redundant
controllers use either two msa Fibre Channel I/O Modules, two msa SAN switch
2/8s, or two msa Hub 2/3s.
msa Fibre Channel I/O Module (Includes 2 Gb SFP transceiver)
msa Hub 2/3 (integrated) (Includes two 2Gb SFP transceivers)
msa SAN Switch 2/8 (integrated) (Includes four 2Gb SFP transceivers)
218960-B21
286763-B21
288247-B21
DA-11621
Canada — Version 2 — April 15, 2003
10
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Configuration Information
STEP 4 – CHOOS E SUPPORTED OPTIONS FOR 2 GB OR 1 GB INFRAS TRUCTURE
2 Gb SFP SW Transceiver Kit
221470-B21
2 Gb Fibre Channel Transceiver
(SFP)
NOTE: “Infrastructure” switches above are interoperable only with HP StorageWorks
MSA SAN Switch 2/8, SAN Switch 2/8EL, 2/16, 2/32, core 2/64 products and all
Power Pak models. They are also interoperable with designated discontinued 1
Gb SAN Switch models.
2 Gb Fibre Channel Fabric
“Infrastructure” family of
switches
HP StorageWorks core 2/64 PowerPak
332178-B21
254508-B21
333764-B21
240603-B21
322119-B21
322118-B21
283056-B21
322121-B21
322120-B21
288247-B21
324504-B21
324506-B21
324507-B21
324508-B21
325891-B21
324505-B21
325892-B21
HP StorageWorks core 2/64
HP StorageWorks SAN Switch 2/32 PowerPak
HP StorageWorks SAN Switch 2/32
HP StorageWorks SAN Switch 2/16 PowerPak
HP StorageWorks SAN Switch 2/16
HP StorageWorks SAN Switch 2/16-EL
HP StorageWorks SAN Switch 2/8 PowerPak
HP StorageWorks SAN Switch 2/8-EL
HP StorageWorks MSA SAN Switch 2/8 (Includes four 2 Gb SFP transceivers)
Fabric Watch for 8 and 16 port switches
ISL Trunking kit for 8 and 16 port switches
Advanced Performance Monitor for 8 and 16 port switches
Quick Loop for 8 and 16 port switches
Remote Switch for 8 and 16 port switches
Extended Fabric for 8 and 16 port switches
HP StorageWorks PowerPak Bundle for 2 Gb Brocade Based 8 and 16 port
Switches(Trunking, Perf Monitor, remote switch, fabric watch, extended fabric)
HP Storageworks 2/8-EL Upgrade license
325888-B21
331148-B21
330883-B21
325887-B21
325886-B21
Optional Rack mount kit for SAN Switch 2/8-EL and SAN Switch 2/16
Remote Switch for HP StorageWorks 2/64
ISL trunking for HP StorageWorks 2/64
•
•
Extended fabric for HP StorageWorks 2/64
NOTE: “High Availability” switches above are interoperable only with HP StorageWorks
Director 2/140. Director 2/64, Edge Switch 2/32, Edge Switch 2/24, and the
discontinued Edge Switch 2/16 products.
2 Gb Fibre Channel Fabric
Switches, “High Availability”
family of switches
HP StorageWorks Director 2/140 (64-ports active)
HP StorageWorks director 2/64
316094-B21
286809-B21
286810-B21
302660-B21
316095-B21
316096--B21
HP StorageWorks edge switch 2/32 (16 active ports)
8-FlexPort upgrade for edge 2/32
HP StorageWorks Edge switch 2/24 (8 ports active)
8-FlexPort upgrade for edge 2/24
MSA Hub 2/3 (integrated option, comes complete with two SFPs)
286763-B21
2 Gb Fibre Channel Integrated
Hub
DA-11621
Canada — Version 2 — April 15, 2003
11
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Configuration Information
STEP 4 – CHOOS E SUPPORTED OPTIONS FOR 2 GB OR 1 GB INFRAS TRUCTURE (continued)
FCA2354 Host Adapter (Tru64 UNIX, OpenVMS)
261329-B21
2 Gb Fibre Channel HBAs
Use 2 Gb Fibre Channel cables when connecting the msa Fibre Channel I/O Module or
the msa Fabric Switch 6 to FCA2101 HBA(s)
Fibre Channel Cables for 2 Gb
Infrastructure
2 m LC-LC Multi-Mode Fibre Channel Cable
5 m LC-LC Multi-Mode Fibre Channel Cable
15 m LC-LC Multi-Mode Fibre Channel Cable
30 m LC-LC Multi-Mode Fibre Channel Cable
50 m LC-LC Multi-Mode Fibre Channel Cable
221692-B21
221692-B22
221692-B23
221692-B26
221692-B27
Use 1 Gb Fibre Channel cables when connecting the msa Fibre Channel I/O Module
and FCA2354 HBA(s) to 1 Gb fabric switches or hubs.
Fibre Channel Cables for 1 Gb
Fabric Switches and Hub
2 m LC-SC Multi-Mode Fibre Channel Cable
5 m LC-SC Multi-Mode Fibre Channel Cable
15 m LC-SC Multi-Mode Fibre Channel Cable
30 m LC-SC Multi-Mode Fibre Channel Cable
50 m LC-SC Multi-Mode Fibre Channel Cable
221691-B21
221691-B22
221691-B23
221691-B26
221691-B27
STEP 5 – CHOOS E HARD DRIVES & STORAGEWORKS ENCLOSURES
Hard Drives
36.4 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″)
72.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″)
146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″)
18.2 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1″)
36.4 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1″)
72.8 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1″)
286713-B22
286714-B22
286716-B22
286775-B22
286776-B22
286778-B22
*NOTE: All Ultra320 Universal Hard Drives are backward compatible to U2 or U3
speeds.
NOTE: For complete compatibility information, refer to the HP SCSI Hard Drive
NOTE: This Web site is available in English only.
DA-11621
Canada — Version 2 — April 15, 2003
12
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Configuration Information
STEP 5 – CHOOS E HARD DRIVES & STORAGEWORKS ENCLOSURES (continued)
The msa1000 cabinet holds fourteen 1” Universal Drives. Add one StorageWorks
Enclosure to increase capacity up to 28 drives. Add two HP StorageWorks Enclosures
to increase capacity up to the maximum of 42 drives.
StorageWorks Enclosures
HP StorageWorks Enclosure Model 4314R (Maximum of two can be connected to the
msa1000)
190209-001
190211-001
HP StorageWorks Enclosure Model 4354R (Maximum of one can be connected to the
msa1000)
STEP 6 – CHOOSE RACK OPTIONS
9142 Rack
120663-B21, -B22, -B23
120664-B21, -B22, -B23
120665-B21, -B22, -B23
222192-B21
9136 Rack
9122 Rack
9842 Rack
10647 (47U) rack
10642 (42U) rack
10636 (36U) rack
10622 (22U) rack
H9A10 Cab
245160-B21, -B23
245161-B21, -B22, -B23
245162-B21, -B22, -B23
245163-B21, -B22, -B23
H9A10-XX
H9A15 Cab
H9A15-XX
DA-11621
Canada — Version 2 — April 15, 2003
13
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Configuration Information
CONFIGURATION EXAMPLES
Two Node Redundant Cluster Solution
Description
HP StorageWorks Modular SAN Array 1000
msa1000 Controller
msa Hub 2/3
Quantity
Part Number
201723-B22
218231-B22
286763-B21
1
1
2
4
Host Adapter
261329-B21
4
14
2 m LC-LC Multi-Mode Fibre Channel Cable
36.4 GB Pluggable Ultra320 Universal Hard Drive, 15K
221692-B21
286776-B21
4 Host, 6TB, Redundant SAN Solution
Description
HP StorageWorks Modular SAN Array 1000
Quantity
Part Number
201723-B22
218231-B22
254786-B21
288247-B21
1
1
2
2
8
8
2
42
msa1000 Controller
256 MB Cache Modules for Controller (one additional for each controller)
msa SAN Switch 2/8 (Includes four 2Gb SFP transceivers)
Host Adapter (appropriate model for operating system)
2 m LC-LC Multi-Mode Fibre Channel Cable
StorageWorks Enclosure Model 4314R
146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″)
221692-B21
190209-001
286716-B22
DA-11621
Canada — Version 2 — April 15, 2003
14
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Technical Specifications
MODULAR SAN ARRAY 1000
Power
LED Indicators on Front (3)
Fault detected in one or more sub-systems
Fault in Enclosure Management
Drive Access (centre)
LED Indicators for Drive
Modules (3)
Online (left)
Drive Failure (right)
Power Supply/Blower Assembly Fault (1)
EMU (3) Power, A bus, B bus
Ultra3 SCSI to Hard Drives
2 Gb Fibre Channel to Hosts
LED Indicators on Rear Panel
(4)
Interface
Fourteen, 1-inch HP Ultra2, Ultra3 or Ultra 320 Universal Hard Drives (msa1000 Cabinet); expandable to 42 using
two additional StorageWorks 4200/4300 Enclosures
Maximum Number of Drives
Temperature Range
Operating
Shipping
50° to 95°F/10° to 35°C
–22° to 122°F/–30° to 50°C
NOTE: Derated 1°C per 1,000 feet of elevation to 10,000 ft.
Operating
10% to 90%
Up to 95%
100 to 240 VAC
50 to 60 Hz
6 A Max
Relative Humidity
Non-operating
Rated Input Voltage
Rated Input Frequency
Rated Input Current
Input Power (max)
1876 Btu/hr*
Input Power Requirements
549 W*
Heat Dissipation (max)
* Input Power and Heat Dissipation specifications are maximum values and apply to worst-case conditions at full
rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment
configuration.
4U Rack Form Factor
msa1000 Cabinet
Dimensions (H x W x D)
Weight
6.9 x 19 x 20.5 in/17.5 x 48.3 x 52.1 cm
Net 55 to 85 lb/24.95 to 38.56 kg
Dimensions (L x W x D)
Weight
28.5 x 14.81 x 33.13 in/72.4 x 37.6 x 84.1 cm
Gross 75 to 105 lb/34.02 to 47.63 kg
Shipping Packaging
DA-11621
Canada — Version 2 — April 15, 2003
15
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Technical Specifications
MODULAR SAN ARRAY 1000 CONTROLLER
Controller Display with Status Indicators (2) and Push Buttons (4)
User Interface
Status Indicators on front of Controller (16)
LVD (Low Voltage Differential)
Wide Ultra3 SCSI (160 MB/s per channel)
4-channel: 2 external/2 Internal
Up to 42 drives
Electrical Interface
Protocol Support
SCSI Ports
Drives Supported
Maximum Capacity
Logical Drives
6.0 TB (42 drives x 146 GB)
Up to 32 logical drives
RAID ADG (Advanced Data Guarding)
RAID 5 (Distributed Data Guarding)
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
RAID Support
Up to 512 MB Read/Write (256-MB modules). Added cache size must match original and if a second controller is
employed, it too must have equally configured cache.
Cache Memory
ECC protection, battery-backed, and removable
Standard, starting November 19, 2002: 256 MB cache memory (single module)
Up to three days of redundant battery life, removable for easy replacement
2 MB flashable ROM
Cache Batteries
Upgradeable Firmware
HP Ultra 320, Ultra3, and Ultra2 SCSI 1-inch Universal drives
Disk Drive and Enclosure
Protocol Support
Dimensions (L x W x D)
Weight
17 x 12.5 x 7.75 in/43.2 x 31.75 x 19.7 cm
Gross 6 lb/2.72 kg
Packaging
MODULAR SAN ARRAY FIBRE CHANNEL I/O MODULE
LC
Connector Type
One 2 Gb Fibre Channel Port using removable Small-Form-Factor-Pluggable Transceiver (SFP)
Number of Fibre Channel Ports
Bandwidth
200 MB/s
Fibre Channel Class 2 and 3 connectionless service
Fibre Channel
Operation Modes
Protocols Supported
Packaging
Dimensions (L x W x D)
Weight
17 x 12.5 x 7.75 in/43.2 x 31.75 x 19.7 cm
Gross 6 lb/2.72 kg
FCA2354 HOST ADAPTER
LC
Connector Type
SCSI, IP
Protocol
64-bit/66 MHz PCI
200 MB/s
Data Transfer Method
Maximum Transfer Rate
Packaging
Dimensions (L x W x D)
Weight
11 x 8.5 x 3 in/27.9 x 21.6 x 7.6 cm
Gross 1 lb/0.45 kg
DA-11621
Canada — Version 2 — April 15, 2003
16
hp StorageWorks
modular SAN array 1000
specific for Tru64 UNIX and OpenVMS only
QuickSpecs
Technical Specifications
MULTI-MODE FIBRE CHANNEL CABLES KITS
LC-LC (2 Gb to 2 Gb connections) and LC-SC (2 Gb to 1 Gb connections) 50 Micron multi-mode fibre
6.5 ft, 16.4 ft, and 49.2 ft/2 m, 5 m, and 15 m
Cable Type
Available Cable Lengths
Packaging
Dimensions (L x W x D)
Weight
11.5 x 9 x 1.5 in/29.2 x 22.8 x 3.8 cm
Gross 0.75 to 1 lb/0.34 to 0.45 kg
© 2003 Compaq Canada Corp. (an HP Company) All rights reserved. Printed in Canada.
Hewlett-Packard, the Hewlett-Packard logo, CarePaq, Open VMS, ProLiant, StorageWorks and Tru64 are trademarks of Hewlett-Packard Company in the
U.S. and/or other countries. UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. All other product names
mentioned herein may be trademarks of their respective companies.
Hewlett-Packard shall not be liable for technical or editorial errors or omissions contained herein. The information is provided “as is” without warranty of any
kind and is subject to change without notice. The warranties for Hewlett-Packard products are set forth in the express limited warranty statements
accompanying such products. Nothing herein should be construed as constituting an additional warranty.
DA-11621
Canada — Version 2 — April 15, 2003
17
|