FieldServer FS 8700 54 User Manual

A Sierra Monitor Company  
Driver Manual  
(Supplement to the FieldServer Instruction Manual)  
FS-8700-54 MDA CM4  
APPLICABILITY & EFFECTIVITY  
Effective for all systems manufactured after May 1, 2001  
Instruction Manual Part Number FS-8700-54  
Version: 1.00fL  
9/19/2000  
FS-8700-54 MDA CM4  
Driver Manual  
1. Zellweger CM4 Description  
The Zellweger CM4 driver allows the FieldServer to transfer data to and from devices over either RS232  
or RS485 using Zellweger CM4 protocol.  
The information that follows describes how to expand upon the factory defaults provided in the  
configuration files included with the FieldServer.  
1.1 Hardware/Software  
Supplied by FieldServer Technologies.  
FieldServer  
Technologies  
PART #  
DESCRIPTION  
8915-10  
8917-02  
UTP cable (7 foot) for RS232 use  
RJ45 to DB9F connector adapter  
FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042  
Page 1  
FS-8700-54 MDA CM4  
Driver Manual  
2. FieldServer as a Zellweger CM4 Client  
2.1 Hardware Connections  
Refer to the Drawings in section 4  
Configure the CM4 according to manufacturer’s instructions  
2.2 Configuration File Structure  
The following tables describe parameters that need to be filled out in the configuration file. For  
convenience, a few example parameters already exist in the supplied PRIMSERV.CSV and  
SECDSERV.CSV files.  
Note that * indicates an optional parameter, with the bold legal value being the default.  
2.2.1 Data Arrays  
Section Title  
Data_Arrays  
Column Title  
Data_Array_Name  
Data_Format  
Function  
Provide name for Data Array  
Provides data format  
Legal Values  
Up to 32 alphanumeric characters  
INT16, INT32, BIT, FLOAT  
1-10,000  
Data_Array_Length  
Number of Data Objects  
Example:  
Data_Arrays  
Data_Array_Name, Data_Format,  
Data_Array_Length  
DA_AI_01,  
DA_AI_02,  
DA_AI_03,  
DA_AI_04,  
DA_AI_11,  
DA_AI_21,  
Uint16,  
Uint16,  
Uint16,  
Uint16,  
Uint16,  
Uint16,  
100  
100  
100  
100  
100  
100  
FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042  
Page 2  
FS-8700-54 MDA CM4  
Driver Manual  
Legal Values  
2.2.2 Client Side Connections  
Section Title  
Connections  
Column Title  
Function  
Specify which port the device is  
connected to the FieldServer  
Specify baud rate  
Specify parity  
Specify data bits  
Port  
P1-P8, R1-R2  
Baud *  
Parity *  
Data_Bits *  
300-9600-38400  
Even, Odd, None  
7, 8  
Stop_Bits *  
Specify stop bits  
1, 2  
Handshaking *  
Specify hardware handshaking  
RTS, RTS/CTS, None  
Example:  
//  
//  
Client Side Connections  
Connections  
Port,  
P8,  
Baud,  
9600,  
Parity,  
None,  
Data_Bits, Stop_Bits, Protocol  
8,  
1,  
CM4  
2.2.3 Client Side Nodes  
Section Title  
Nodes  
Column Title  
Node_Name  
Node_ID  
Function  
Provide name for node  
Node ID of physical server node  
(PLC or Slave Device)  
Specify protocol used  
Legal Values  
Up to 32 alphanumeric characters  
1-255  
Protocol  
Modbus/TCP, Modbus RTU, etc  
Example:  
//  
//  
Client Side Nodes  
Nodes  
Node_Name,  
CN_CM4_1,  
Node_ID, Protocol, Connection  
1, CM4, P8  
FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042  
Page 3  
FS-8700-54 MDA CM4  
Driver Manual  
2.2.4 Client Side Map Descriptors  
Section Title  
Map_Descriptros  
Column Title  
Map_Descriptor_Name  
Data_Array_Name  
Function  
Legal Values  
Name of this Map Descriptor  
Name of Data Array where data is  
to be stored in the FIeldServer  
Starting location in Data Array  
Up to 15 alphanumeric characters  
One of the Data Array names from  
“Data Array” section above  
0 to maximum specified in “Data  
Array” section above  
Data_Array_Location  
Function  
Node_Name  
Function of Client Map Descriptor  
Name of Node to fetch data from  
RDBC, WRBC, WRBX  
One of the node names specified in  
“Client Node Descriptor” above  
Current Point Status, Unit Status,  
System Information  
Data_Type  
Data type  
Length  
Address  
Scaling  
Length of Map Descriptor  
Starting address of read block  
If scaling is required  
1 - 100  
0, 1, 2, 3 *  
Data_Array_Low_Scale*  
Scaling zero in Data Array  
-32767 to 32767, default 0  
Data_Array_High_Scale*  
Scaling max in Data Array  
-32767 to 32767, default 100  
Node_Low_Scale*  
Node_High_Scale*  
Scaling zero in Connected Node  
Scaling max in Connected Node  
-32767 to 32767, default 0  
-32767 to 32767, default 100  
* 0 If Unit Status, System Information.  
0, 1, 2, 3 If Current Point Status.  
Example:  
//  
//  
Client Side Map Descriptors  
Map_Descriptors  
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name, Data_Type, Address  
CMD_AI_01,  
CMD_AI_02,  
CMD_AI_03,  
CMD_AI_04,  
CMD_AI_11,  
CMD_AI_21,  
DA_AI_01,  
DA_AI_02,  
DA_AI_03,  
DA_AI_04,  
DA_AI_11,  
DA_AI_21,  
0,  
0,  
0,  
0,  
0,  
0,  
RDBC,  
RDBC,  
RDBC,  
RDBC,  
RDBC,  
RDBC,  
CN_CM4_1, CPS*,  
CN_CM4_1, CPS*,  
CN_CM4_1, CPS*,  
CN_CM4_1, CPS*,  
CN_CM4_1, Unit Status, 0  
CN_CM4_1, SI**,  
0
1
2
3
0
*->  
**->  
Current Point Status  
System Information  
FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042  
Page 4  
FS-8700-54 MDA CM4  
Driver Manual  
2.3 Troubleshooting Data Array Maps  
Current Point Status  
Data Array  
Offset  
Function  
0
Function Code always 55  
1
2
3
4
5
Current Date: Year  
Current Date: Month  
Current Date: Day  
Current Time: Hour  
Current Time: Minute  
Current Time: Second  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
Gas Abbreviation Code  
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
Format Code  
Current Flow  
Time and Date TWA Start Current Date: Year  
Time and Date TWA Start Current Date: Month  
Time and Date TWA Start Current Date: Day  
Time and Date TWA Start Current Time: Hour  
Time and Date TWA Start Current Time: Minute  
Time and Date TWA Start Current Time: Second  
Time and Date TWA End Current Date: Year  
Time and Date TWA End Current Date: Month  
Time and Date TWA End Current Date: Day  
Time and Date TWA End Current Time: Hour  
Time and Date TWA End Current Time: Minute  
Time and Date TWA End Current Time: Second  
TWA Concentration  
Last Concentration  
Alarm Status  
Status  
FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042  
Page 5  
FS-8700-54 MDA CM4  
Unit Status  
Driver Manual  
Data Array  
Offset  
Function  
Function Code always 55  
0
1
2
3
4
5
6
Current Date: Year  
Current Date: Month  
Current Date: Day  
Current Time: Hour  
Current Time: Minute  
Current Time: Second  
7
General Status  
8
New Events  
9
Concentration Summary  
Chem Casette Remaining Window  
Chem Casette Remaining Day  
Internal Filter  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
External Filter  
Flow Rate Point 1  
Flow Rate Point 2  
Flow Rate Point 3  
Flow Rate Point 4  
Optics Cal Status  
Maintenance Status  
FieldServer Technologies 1991 Tarob Court, Milpitas, California 95035 (408) 262-2299 fax: (408) 262-9042  
Page 6  

Microsoft Windows 7 Home Premium With Service Pack QGF00154 User Manual
LG Electronics VX3450L User Manual
Kyocera VMS130 User Manual
Kenwood KDC C469FM User Manual
Hitachi Travelstar 0F12115 User Manual
Fujitsu Computer Drive MHY2250BH User Manual
Freecom Technologies II User Manual
Fostex CD 1A User Manual
Clarion DRB365D User Manual
Bodum 8 Cup Black Vacuum Coffee Maker 1208 01 User Manual