		 User’s Guide   
					
					Models:   
					f 
					CBS-2031e / CBS-2031s   
					CBS-2032e / CBS-2032s   
					f 
					NOTICE TO INSTALLER: Please leave this book with the machine.   
					Table of Contents   
					Contact Information ..................................................2   
					Operating Instructions ..............................................8   
					Programming............................................................9   
					Batch Settings.......................................................9   
					Temperature Settings .........................................10   
					Advanced Settings and Diagnostics ...................10   
					Relay Test...........................................................11   
					Error Codes ............................................................12   
					Parts .......................................................................13   
					Description & Features.............................................2   
					Specifications............................................................2   
					Requirements........................................................2   
					Weights and Capacities ........................................2   
					Electrical Configuration and Brewing Efficiency ...3   
					Dimensions & Utility Connections.............................4   
					Installation.................................................................5   
					FETCO®, LUXUS®, EXTRACTOR® and Driven To Pioneer Innovation™ are trademarks or trade names of Food Equipment Technologies Company.   
					© 2005 Food Equipment Technologies Company Part # P019 August 16, 2005   
				Electrical Configuration and Brewing Efficiency   
					US & Canada   
					CBS-2031e / CBS-2031s   
					3.0 liters per batch   
					Batches per Hour* (max 11)   
					Electrical   
					Heater   
					Voltage   
					(AC)   
					Maximum   
					Amp draw   
					Config. Code   
					Configuration   
					Phase   
					Wires   
					KW   
					1.6   
					2.4   
					2.6   
					3.1   
					Cold Water   
					Hot Water   
					E31045   
					Can be connected   
					1 X 1.5 KW   
					2 X 1.5 KW   
					120   
					single 2 + ground   
					13.0   
					11.3   
					12.0   
					13.0   
					4.9   
					11.0   
					120/208 single 3 + ground   
					120/220   
					120/240   
					7.3   
					11.0   
					to 120 VAC or   
					8.2   
					11.0   
					120/208-240 VAC   
					9.7   
					11.0   
					E31035   
					Can be connected   
					1 X 1.7 KW   
					2 X 1.7 KW   
					120   
					single 2 + ground   
					1.8   
					2.7   
					3.0   
					3.5   
					14.7   
					12.8   
					13.5   
					14.7   
					5.5   
					8.3   
					9.2   
					11.0   
					11.0   
					11.0   
					11.0   
					120/208 single 3 + ground   
					120/220   
					120/240   
					to 120 VAC or   
					120/208-240 VAC   
					11.0   
					E31015   
					Can be connected   
					1 X 2.3 KW   
					2 X 2.3 KW   
					120   
					single 2 + ground   
					2.4   
					3.6   
					4.1   
					4.7   
					19.7   
					17.1   
					18.1   
					19.7   
					7.4   
					11.0   
					11.0   
					11.0   
					11.0   
					120/208 single 3 + ground   
					120/220   
					120/240   
					11.0   
					11.0   
					11.0   
					to 120 VAC or   
					120/208-240 VAC   
					CBS-2032e / CBS-2032s   
					3.0 liters per batch   
					Batches per Hour* (max 22)   
					Electrical   
					Heater   
					Voltage   
					(AC)   
					Maximum   
					Amp draw   
					Config. Code   
					Configuration   
					Phase   
					Wires   
					KW   
					Cold Water   
					Hot Water   
					E32015   
					2 X 3 KW   
					120/208 single 3 + ground 4.6   
					22.4   
					23.7   
					25.8   
					14.6   
					16.9   
					19.4   
					22.0   
					22.0   
					22.0   
					120/220   
					120/240   
					5.1   
					6.1   
					* Based on standard factory settings: 4.0 minute brew time; 0% prewet; 200 F water.   
					Export   
					CBS-2031e / CBS-2031s   
					3.0 liters per batch   
					Batches per Hour* (max 11)   
					Electrical   
					Heater   
					Voltage   
					(AC)   
					Maximum   
					Amp draw   
					Config. Code   
					Configuration   
					Phase   
					Wires   
					KW   
					Cold Water   
					Hot Water   
					E31025   
					1 X 3 KW   
					220   
					single 2 + ground 2.6   
					12.0   
					8.4   
					11..0   
					CBS-2032e / CBS-2032s   
					3.0 liters per batch   
					Batches per Hour* (max 22)   
					Electrical   
					Heater   
					Voltage   
					(AC)   
					Maximum   
					Amp draw   
					Config. Code   
					Configuration   
					Phase   
					Wires   
					KW   
					Cold Water   
					Hot Water   
					E32025   
					2 X 3 KW   
					220   
					single 2 + ground 5.1   
					23.7   
					16.9   
					22.0   
					* Based on standard factory settings: 4.0 minute brew time; 0% prewet; 200 F water.   
					3 
				Dimensions & Utility Connections   
					CBS-2031e / CBS-2031s   
					DWG 201108-000   
					CBS-2032e / CBS-2032s   
					DWG 201109-000   
					4 
				Installation   
					(For Qualified Service Technicians Only)   
					Keys To A Successful Installation   
					If not installed correctly by qualified personnel, the brewer will not operate properly and damage may result.   
					Damages resulting from improper installation are not covered by the warranty.   
					Here are the key points to consider before installation:   
					Electrical:   
					 All FETCO brewers require NEUTRAL. Ground is not an acceptable substitute. Installation without neutral   
					may cause damage to the electronic components.   
					 The electrical diagram is located on the inside of the lower cover.   
					 The installation must comply with applicable federal, state, and local codes having jurisdiction at your   
					location. Check with your local inspectors to determine what codes will apply.   
					Plumbing:   
					 This equipment is to be installed to comply with the applicable federal, state, or local plumbing codes.   
					 The water line must be flushed thoroughly prior to connecting it to the brewer to prevent debris from   
					contaminating the machine.   
					 Verify that the water line will provide at least ¼ gallon per minute for the CBS-2031, and ½ gallons per   
					minute for the CBS-2032 before connecting it to the brewer.   
					General:   
					 Utilize only qualified beverage equipment service technicians for installation. A Service Company Directory   
					
					Installation Instructions   
					Brewer Setup   
					1. Review the Dimensions for the unit you are installing. Verify that the brewer will fit in the space intended for it,   
					and that the counter or table will support the total weight of the brewer and dispensers when filled.   
					2. The brewer’s legs are shipped inside the brew baskets.   
					Warning: Legs are to be adjusted for   
					leveling the brewer only. Do not use   
					for height adjustment or extend them   
					higher than necessary.   
					Remove the brew basket(s) and the coffee dispenser(s).   
					Place the brewer on its back and screw in the legs.   
					3. Place the brewer on the counter or stand.   
					4. When the brewer is in position, level it front to back as well   
					as side to side by adjusting the legs.   
					5. Remove the lower cover to access the water and electrical connections. Knock-outs are provided in the back   
					and base of the brewer body for the connections.   
					Water Connection   
					1. Water inlet is a 3/8 inch male flare fitting.   
					2. The brewer can be connected to a cold or hot water line. Cold water is preferred for best coffee flavor, but hot   
					water will allow for faster recovery times.   
					3. Install a water shut off valve near the brewer to facilitate service. If an in-line water filter is used, it should be   
					installed after the water shut off valve and in a position to facilitate filter replacement.   
					4. Flush the water supply line and filter before connecting it to the brewer.   
					5. Verify that the water line will provide at least ¼ gallon per minute for the CBS-2031, and ½ gallon per minute   
					for the CBS-2032, and that the water pressure is between 20 and 75 psig.   
					5 
				Electrical Connection – US & Canada   
					1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the   
					brewer’s serial number label. Make sure the electrical service includes neutral.   
					2. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters   
					during the installation process. The heaters are disabled by the control board until the tank is full of water. The   
					heating process will start automatically when the tank has filled.   
					3. The CBS-2031 is factory equipped with a 120 V cord and plug. The CBS-2032 has only a terminal block for   
					connecting the incoming power wires. Consult local codes to determine if a cord and plug can be installed, or if   
					the unit must be hard wired.   
					4. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the   
					brewer, and its location and markings known to the operators.   
					Warning: To prevent   
					electrical shock, this   
					unit must be properly   
					grounded.   
					5. The body of the brewer must be grounded to a suitable building ground.   
					A ground lug is provided in the brewer next to the power terminal block.   
					Use only 10 gauge copper wire for grounding.   
					6. Electrical connections must be secured in-place within the unit to meet   
					national and local standards.   
					7. Finally, connect the incoming power wires to the terminal block as shown in accordance with applicable codes.   
					CBS-2031e / CBS-2031s   
					Can be connected to 120 VAC or 120/208-240 VAC   
					Factory Configuration   
					120 VAC, 3 wires   
					Optional Field Conversion*   
					120/208-240 VAC, 4 wires   
					Step 1: Remove the factory provided 120 V cord &   
					plug from the terminal block.   
					Step 2: Connect the incoming wires to the terminal   
					block in accordance with applicable codes.   
					L1   
					N 
					L2   
					GROUND   
					GROUND LUG   
					L1   
					N 
					L2   
					L2 - NOT USED   
					CORD WITH   
					NEMA 5-20P PLUG   
					120V   
					120V   
					N 
					GROUND   
					WIRE   
					208-240V   
					*This procedure must be performed only by a qualified   
					service technician or electrician.   
					Notice: In order for this product to comply with the   
					requirements of the Underwriters Laboratories listing,   
					the following conditions apply:   
					1.) This unit must be hard wired for 120/208-240 VAC.   
					2.) Once the unit is converted to 120/208-240 VAC   
					operation, it cannot be converted back to 120   
					VAC operation.   
					CBS-2032e / CBS-2032s   
					Can be connected only to 120/208-240 VAC   
					GROUND LUG   
					L1   
					N 
					L2   
					120V   
					120V   
					N 
					GROUND   
					WIRE   
					208-240V   
					6 
				Final Setup   
					1. Turn on the incoming water supply line and inspect both inside   
					and outside of the brewer for leaks in all fittings and tubes   
					2. Turn on the incoming power.   
					3. Press the brewer’s main power switch, which is hidden behind the   
					front leg of the brewer. The control panel on/off switch will begin   
					flashing. Press this switch.   
					4. Within 6 seconds, the hot water tank will begin filling until the   
					water is sensed by the probe at the top of the tank. The display will   
					read “FIL”. The heaters will be disabled by the control board until   
					the tank is full.   
					5. While the water is heating, the display will read “LO” and the   
					actual water temperature will be displayed. After the water has   
					reached the set temperature, the display will be blank. There is no   
					“ready” light.   
					6. Review the Operating Instructions. Brew one full batch (water   
					only) on each side to confirm proper fill levels. The brewer is   
					factory set with water only (no coffee) to dispense the correct   
					amount of water. If the actual volume is slightly different from the   
					programmed volume, fine tuning the brewer may be necessary.   
					See #60 – 61 in the Advanced Settings & Diagnostics section.   
					7. Re-attach the covers after one final inspection for leaks. Look   
					closely in the top of the brewer at the dispense fittings during this   
					inspection.   
					Operator Training   
					Review the operating procedures with whoever will be using the   
					brewer. Pay particular attention to the following areas:   
					1. Always pre-heat the dispensers before the first use of each day by   
					filling them half way with hot water, and letting them stand for at   
					least 15 minutes.   
					2. Don't remove the brew basket until it has stopped dripping.   
					3. Make sure the dispenser is empty before brewing into it.   
					4. Show how to attach covers, close, and or secure the thermal   
					dispensers for transporting.   
					5. Show the location and operation of the water shut off valve as well   
					as the circuit breaker for the brewer.   
					6. Steam from the tank will form condensation in the vent tubes. This   
					condensation will drip into and then out of the brew baskets. 1/4   
					cup discharging overnight is possible. Place an appropriate   
					container under each brew basket when not in use.   
					7. We recommend leaving the power to the brewer on overnight. The   
					water tank is well insulated and will use very little electricity to   
					keep the tank hot. Leaving the brewer in the on position will also   
					avoid delays at the beginning of shifts for the brewer to reach   
					operating temperature.   
					7 
				Operating Instructions   
					Control Panel Functions   
					Only switches that are active are illuminated.   
					Switches that are inactive or disabled are invisible.   
					X Main Power Switch   
					 Controls all power to brewer   
					 Indicator lamp at top of panel.   
					Y Control Panel On/Off Switch   
					 Affects only control panel. Does   
					not disconnect main power.   
					 Flashing = Off   
					 Lit = On   
					 Invisible = Main Power Off   
					Z Display   
					 ”FILL” = Water tank is filling.   
					 ”LO XXX” = Unit is heating, not   
					ready to brew. (XXX = actual   
					temperature.)   
					 Blank = Ready to brew.   
					 Also displays error messages.   
					[ Stop Switches   
					 Stops brew cycle   
					 Lit = Brew cycle in progress   
					 Invisible = Not brewing, or dripping   
					in progress   
					\ Brew Switches   
					 Starts brew cycle   
					 Must be held in for 1 second   
					 Flashing = Brew cycle in progress   
					 Lit = Ready to brew   
					 Invisible – Not ready to brew, or   
					batch disabled   
					(See Programming Section)   
					] Hot Water Switch   
					 Dispenses hot water from faucet   
					 Hold in to dispense   
					Brewing   
					1. Turn the main power switch and control   
					panel switch on.   
					7. When the brew cycle is finished, the STOP   
					button will extinguish and the BREW button will   
					continue flashing, indicating that coffee may still   
					be dripping from the bottom of the brew basket.   
					8. Before removing the brew basket or dispenser,   
					visually verify that dripping has stopped.   
					Notes:   
					2. Prepare a brew basket with the correct size   
					filter and appropriate amount of coffee.   
					3. Slide the brew basket completely into the   
					rails.   
					4. Place a clean, empty, preheated dispenser   
					under the brew basket.   
					5. Select a batch from the available choices,   
					and hold the corresponding BREW button in   
					for 1 second to start the brew cycle.   
					6. The STOP button will illuminate, and the   
					selected BREW button will flash, indicating   
					that brewing is in progress. All other BREW   
					buttons will extinguish.   
					 
					Preheat dispenser by filling at least ½ full with   
					water at brewing temperature. Allow it to sit for   
					at least 15 minutes before draining.   
					8 
				Programming   
					Display   
					Batch Settings   
					 
					Turn the brewer off by pressing the main power switch.   
					 
					Press the main power switch again to turn the unit on.   
					32   
					The last 2 digits of the model number will display briefly, then S t b.   
					S t b   
					 
					 
					 
					 
					Quickly hold the STOP button for 3 seconds.   
					The display will show the software version. Example:   
					Press STOP to continue.   
					P r G   
					MAIN POWER   
					SWITCH IS   
					BEHIND   
					0.0 3.2   
					FRONT LEG.   
					Batches are numbered 1 – 2 (single brewers) or 1 – 4 (dual brewers)   
					PARAMETER   
					BATCH #   
					SETTING   
					1.1 2.49   
					Example: Left Side – Large Batch – Volume 2.49 Liters.   
					 
					Next, the first batch parameter is displayed – batch 1, brew volume   
					Use the SCROLL UP and SCROLL DOWN buttons to adjust.   
					Press the STOP button to go to the next parameter – brew time.   
					1.1 2.49   
					1.2 4.00   
					 
					 
					Continue this way until all parameters are programmed for batch #1.   
					(See the chart below for an explanation of each parameter.)   
					Next, batch #2 programming begins.   
					2.0 OFF   
					Batches 2 and 4 may be disabled by leaving them set to “OFF”.   
					Change to “ON” to enable. Batches 1 and 3 cannot be disabled.   
					 
					After all batches are programmed, go to temperature settings.   
					7 
					200   
					(See next page)   
					Important! After programming, you must press the HOT WATER button to save the settings and exit   
					programming mode, or changes will be lost. You may exit programming at any time.   
					Batch Parameters   
					X=Batch Number (1 - 4)   
					Parameter   
					Name   
					Range   
					Increment   
					Default Setting   
					Comment   
					X.0   
					Batch Enabled or   
					Disabled   
					Brew Volume (Liters) 0.94 – 4.72   
					On/Off   
					Batch 1 & 3 = ON   
					Batch 2 & 4 = OFF   
					2.49 liters   
					Batch 1 & 3 cannot be   
					disabled.   
					To display gallons,   
					see # 59 in Advanced   
					Settings section.   
					X.1   
					0.03 or   
					0.04   
					X.2   
					X.3   
					Brew Time (Min:Sec) 2:00 – 24:00   
					0:30   
					1%   
					4:00 minutes   
					0 %   
					Bypass Percent   
					0.00 – 40.0%   
					0.00 – 15.0%   
					0:10 – 5:00   
					Percentage of total   
					brew volume   
					Percentage of total   
					brew volume   
					The time between   
					prewetting and start of   
					brew cycle.   
					(CBS-2031s / 2032s only)   
					X.4   
					X.5   
					Prewet Percent   
					1%   
					0 %   
					Prewet Delay   
					(Min:Sec)   
					0:10   
					1:00 minute   
					X.6   
					Drip Delay (Min:Sec) 0:30 – 6:00   
					Minutes   
					0:10   
					1:00 minute   
					The time between end   
					of brew cycle and   
					when brew switch   
					stops blinking.   
					9 
				Temperature Settings   
					Parameter   
					Name   
					Range   
					Default Setting   
					Comment   
					7 
					Inside tank. Will be slightly lower at   
					spray head. To display in ° Celsius,   
					see # 58 in Advanced Settings.   
					A= Faucet will dispense only when not   
					brewing.   
					On=Faucet always enabled.   
					Off=Faucet always disabled.   
					0=Will brew at any temperature.   
					1=Will brew only at set temperature.   
					Note: Changes will not take effect until   
					the next brew cycle is completed.   
					Water Temp. (°F)   
					180°F - 208°F   
					200°F   
					8 
					9 
					Hot Water Service   
					A (auto) / On / Off   
					A (auto)   
					1 
					Brew at Set   
					Temperature   
					0 - 1   
					Parameter   
					Name   
					Range   
					Default Setting   
					Comment   
					10   
					Enter Advanced   
					Settings &   
					Diagnostics   
					0 - 1   
					0 
					0 = Skip Advanced Settings &   
					Diagnostics. Loop back to start of   
					batch programming cycle.   
					1 = Enter Advanced Settings &   
					Diagnostics.   
					Press STOP to continue   
					Important! To save your changes, press   
					to exit programming mode and return to operating mode.   
					Advanced Settings and Diagnostics   
					Address   
					Description   
					Water Level   
					in Tank   
					Range   
					Default   
					Comment   
					50   
					0 - 1   
					Tests if water is touching probe.   
					0 = Tank is less than full   
					1 = Tank is full   
					52   
					Brew Basket   
					Sensor State   
					(left / right)   
					0 - 1   
					CBS-2031s / CBS-2032s Only   
					To test, slide the brew basket in and out. Display   
					should toggle between 0 and 1.   
					0 = Brew basket out. 1 = Brew Basket in.   
					Displays current tank temperature. If temperature   
					is below 175°F, displays “LO”.   
					Must be set for the correct model number of the   
					brewer: 31 for CBS-2031e or 2031s, 32 for CBS-   
					2032e or 2032s.   
					55   
					56   
					Tank Temperature   
					180°F - 208°F   
					Brewer Model   
					Number   
					31 - 52   
					57   
					Reload Defaults   
					0 - 1   
					0 
					Changes all settings to default factory settings.   
					0 = Do not reload defaults   
					1 = Reload all default settings   
					If 1 is selected, you must advance to the next   
					address for this change to take effect.   
					Does not change address 56 – model number.   
					F = Displays temp in degrees Fahrenheit   
					C = Displays temp in degrees Celsius   
					LTR = Displays volume in liters   
					58   
					59   
					Temperature Scale F or C   
					F 
					Water Volume   
					Scale   
					LTR or GAL   
					LTR   
					GAL = Displays volume in gallons   
					10   
				Address   
					60   
					and   
					61   
					Description   
					Range   
					Default   
					Comment   
					Left Brew Valve   
					Flow Rate   
					Right Brew Valve   
					Flow Rate   
					0.35 – 2.24   
					If #59 is LTR   
					1.48   
					Use this to compensate for minor discrepancies in   
					actual volume versus programmed volume. Set   
					lower to increase volume, higher to decrease   
					volume. The following formula can be used to   
					determine the correct setting:   
					or   
					0.09 – 0.59   
					If #59 is GAL   
					0.39   
					0 
					ACTUAL VOLUME   
					CURRENT   
					SETTING   
					NEW   
					SETTING   
					X 
					= 
					PROGRAMMED VOLUME   
					64   
					65   
					Keypad Test   
					0 - 1   
					Tests function of control panel switches.   
					0 - Skip keypad test   
					1 - Keypad test active   
					Starting at the top, press each button. Display will   
					read the name of the switch being pressed.   
					Brew switches are named S1, S2, S3, etc.   
					The hot water switch must be pressed last, as this   
					will exit the test.   
					Relay Test   
					0 - 1   
					0 
					0 - Skip relay test. Loop back to #50   
					1 – Relay test active.   
					Press STOP to continue   
					Press   
					Press   
					to save the settings and exit Diagnostic mode.   
					again to exit Programming mode and return to Operating mode.   
					Warning: During these   
					tests, hot water may   
					be dispensed from   
					Relay Test   
					Tests the individual relays which control various components.   
					Use either batch button to actuate the relays.   
					the valve being tested.   
					To begin, you must first press the blinking Control Panel Power Switch.   
					Address   
					Description   
					Comment   
					90   
					91   
					92   
					93   
					94   
					95   
					Left or Single Brew Valve   
					Right Brew Valve   
					Left or Single Bypass Valve   
					Right Bypass Valve   
					Hot Water Faucet   
					Fill Valve   
					CBS-2031s / CBS-2032s Only   
					CBS-2031s / CBS-2032s Only   
					96   
					Heater   
					To protect the heaters, this test will work only if the tank is full.   
					Press   
					to exit Relay Test.   
					Press   
					Press   
					again to exit Diagnostic mode.   
					again to exit Programming mode and return to Operating mode.   
					11   
				Error Codes   
					How to Clear Error   
					Codes   
					Code   
					Description   
					Possible Cause   
					Corrective Action   
					001   
					Internal Error   
					System had to reload default   
					settings.   
					Control board failure.   
					Clear error.   
					Turn main power   
					switch off and on.   
					Re-program the brewer to the   
					desired specifications. If error   
					occurs again, replace control   
					board.   
					050   
					051   
					Shorted temperature probe.   
					Open temperature probe.   
					Probe failure.   
					Replace probe.   
					Turn main power   
					switch off and on.   
					Turn main power   
					switch off and on.   
					Bad probe connection, or Check all connections. Replace   
					probe failure.   
					probe if necessary.   
					075   
					or   
					NO   
					BAS   
					CBS-2031e / 2032e   
					Brew Basket Sensor   
					These models do not   
					have brew basket   
					sensors or locks. This   
					error indicates a bad   
					connection on the brown   
					jumper wire on the Molex   
					connector connected to   
					the top of the control   
					board.   
					Press both ends of the jumper   
					wire into the connector to make   
					better contact.   
					075   
					CBS-2031s / 2032s   
					Brew basket lock or sensor   
					failure.   
					Brew basket sensor or   
					lock has failed.   
					Repair or replace brew basket   
					sensor or lock.   
					Press the flashing   
					control panel power   
					switch to resume   
					operation.   
					If the brew basket can be   
					pulled out during the   
					brew cycle, the brew   
					basket lock has failed.   
					Magnet in brew basket   
					handle is missing or   
					loose.   
					Remove brew basket handle.   
					Place magnet in correct   
					position.   
					100   
					101   
					102   
					Initial Fill Error   
					Initial fill time was more than   
					15 minutes.   
					Water supply flow rate is   
					too low.   
					Watch for short potting during   
					Press the control   
					brew cycle. Investigate cause of panel power switch.   
					low flow rate. (Clogged water   
					filter, etc.)   
					Watch for short potting during   
					brew cycle. Investigate cause of cleared automatically   
					low flow rate. (Clogged water   
					filter, etc.)   
					Check inside of machine for   
					leaks.   
					Error on refill   
					Tank did not refill within 3   
					minutes.   
					Water supply flow rate is   
					too low.   
					Error message is   
					at end of brew cycle.   
					Unwanted Fill   
					Possible leak in tank,   
					fitting, or valve.   
					Turn main power   
					switch off and on.   
					When brewer is idle, the fill   
					valve was activated for more   
					than 30 seconds during a 1   
					hour period.   
					Output on control board   
					has failed, causing a   
					dispense valve to open.   
					Replace control board.   
					200   
					201   
					Flat Line Temperature   
					(Water is boiling)   
					System is calling for heat, but   
					the temperature does not rise   
					at least 2°F within 10 minutes.   
					Heater Open   
					System is calling for heat, but   
					the temperature does not rise   
					at least 2°F within 10 minutes.   
					This error is disabled during   
					brewing and while using the   
					hot water faucet.   
					Triac is stuck closed, bad Check triacs, check control   
					Turn main power   
					switch off and on.   
					output on control board,   
					or temperature is set too   
					high for altitude.   
					board output, or adjust   
					temperature for altitude.   
					Heating element failure.   
					Check and replace heating   
					elements if necessary.   
					Turn main power   
					switch off and on.   
					202   
					255   
					Heater Short   
					Possible triac stuck   
					closed, or bad output on   
					control board.   
					Check triac and control board.   
					Enter programming   
					mode, then exit   
					programming mode.   
					System is not calling for heat,   
					but temperature rises more   
					than 5°F.   
					Keypad Error   
					Switch was held in too   
					Clear error and try again. If   
					error occurs without switch   
					being pressed, replace input   
					board.   
					Turn main power   
					switch off and on.   
					A switch was pressed for more long, or switch is stuck   
					than 45 seconds. closed.   
					12   
				Parts   
					Figure 1 – CBS-2031e / CBS-2031s Main Assembly   
					DWG 101194-C   
					ITEM #   
					QTY   
					PART # DESCRIPTION   
					1 
					2 
					2 
					3 
					4 
					5 
					1 
					1 
					1 
					2 
					4 
					1 
					001051 WELDMENT CBS-2031e   
					108001 SWITCHING/CONTROL BOARD, 5 KEYS, S2P (CBS-2031e ONLY)   
					108037 SWITCHING/CONTROL BOARD, 5 KEYS, S2P (CBS-2031s ONLY)   
					29007 NUT, #4-40 KNURLED THUMB   
					15007 STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2"   
					51042 BOARD, POWER SUPPLY-120VAC   
					EXPORT   
					220V ONLY   
					5 
					1 
					51055 BOARD, POWER SUPPLY-220VAC   
					6 
					7 
					4 
					1 
					29019 SPACER, .25" HEX x 1" LG., FEM, #4-40 THREAD   
					57006 FILL VALVE, S-53 120VAC   
					EXPORT   
					220V ONLY   
					7 
					1 
					57017 FILL VALVE, S-53 220VAC   
					8 
					9 
					10   
					11   
					12   
					13   
					1 
					1 
					1 
					4 
					1 
					1 
					24012 GASKET, S-53 FILL VALVE   
					31078 FITTING, S-53 FILL VALVE INLET   
					03074 BRACKET, S-53   
					82020 SCREW, S-53 FILL VALVE   
					31031 FITTING, 90º MALE ELBOW, 3/8 TUBE OD X 3/8 MPT   
					86040 CONNECTOR, CABLE CLAMP, 3/4"   
					13   
				14   
					15   
					16   
					17   
					17   
					17   
					18   
					19   
					20   
					1 
					1 
					2 
					1 
					1 
					1 
					7 
					13   
					1 
					52050 TERMINAL BLOCK   
					65002 CONNECTOR, COPPER LUG   
					86032 BUSHING, SNAP, 1" MOUNTING HOLE DIA   
					102189 ASSEMBLY, POWER BRACKET, CBS-2000e   
					52026 CIRCUIT BREAKER, 5A   
					58054 SWITCH, PUSH BUTTON   
					83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE,   
					84002 NUT, HEX, #8-32 MACHINE SCREW   
					102080 ASSEMBLY, SMALL SPRAY HEAD, 120V (SEE FIG. 5)   
					EXPORT   
					220V ONLY   
					20   
					1 
					102158 ASSEMBLY, SMALL SPRAY HEAD, 220V (SEE FIG. 5)   
					21   
					22   
					23   
					24   
					25   
					25   
					1 
					1 
					4 
					2 
					1 
					002065 WELDMENT, HOT WATER FAUCET   
					33007 LOCKNUT, 7/16 STRAIGHT PIPE THREAD   
					73029 LEG, THERMOPLASTIC, 2.50"(63mm)   
					29021 SPACER, #8 SCREW SIZE, ½ OD X ¼ LG, ROUND UNTH.   
					102192 ASSEMBLY, HOT WATER VALVE, 120VAC   
					57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					EXPORT   
					220V ONLY   
					EXPORT   
					25   
					25   
					1 
					102193 ASSEMBLY, HOT WATER VALVE, 220VAC   
					57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					220V ONLY   
					25   
					26   
					27   
					28   
					29   
					30   
					31   
					32   
					33   
					34   
					35   
					36   
					37   
					38   
					38   
					39   
					40   
					41   
					42   
					44   
					45   
					46   
					47   
					48   
					49   
					50   
					51   
					52   
					53   
					54   
					55   
					57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   
					83051 WASHER, #8 SCREW SIZE, FLAT   
					104028 ASSEMBLY TANK CBS-2031e (SEE FIG 2)   
					22062 INSULATION TANK FRONT CBS-2031e   
					22063 INSULATION TANK BACK CBS-2031e   
					45077 OVERLAY CBS-2031e   
					41016 LABEL, EXTRACTOR   
					46029 LABEL, POWER SWITCH   
					102139 ASSEMBLY, WATER LEVEL PROBE, CBS-2030   
					102190 ASSEMBLY, DIGITAL TEMP. PROBE, 5.0" LG.   
					44004 LABEL GROUND   
					402025 HARNESS, LOW AMP, ELECTRICAL, CBS-2031e, TWO HEATERS   
					402035 HARNESS, HIGH AMP, ELEC. 2 HEATER WIRE SET CBS-2031e   
					63019 CORD, 120 VAC, 12/3 AWG ,20 AMP , W/5-20P NEMA PLUG   
					63018 CORD, 120 VAC, 12/3 AWG ,15 AMP , W/5-15P NEMA PLUG   
					25056 TUBE, 3/4"OD X 1/2"ID X 4"LG, BREW   
					25058 TUBE 5/8"OD X 3/8"ID X 2.5"LG, HOT WATER FAUCET   
					86038 CLAMP, HOSE, .670"-.780" DIA RANGE   
					86020 CLAMP, HOSE, .875"-.750" DIA RANGE   
					25059 TUBE, 5/16"OD X 3/16"ID X 9 1/4"LG VENT   
					25102 TUBE, 1/4"OD X 1/8"ID X 20" LG VENT HOT WATER VALVE   
					25055 TUBE, 5/8"OD X 3/8"ID X 12"LG DRAIN   
					25057 TUBE, 5/8"OD X 3/8"ID X 14 1/2"LG, COLD WATER   
					25064 TUBE, 5/8"OD X 3/8"ID X 6.5"LG. HOT WATER   
					86007 CLAMP, HOSE, .593"-.656" DIA RANGE   
					01506 COVER TOP CBS-2031 & 41   
					2 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					3 
					1 
					1 
					1 
					1 
					1 
					1 
					5 
					1 
					1 
					1 
					1 
					10   
					1 
					01507 COVER BASE UPPER CBS-2031   
					401217 WIRING DIAGRAM, CBS-2031e, L1, L2, N, + GR   
					102191 ASSEMBLY, RIGHT COVER CBS-2030's   
					82053 SCREW, # 6-32 X 1/2" TRUSS HD PH   
					101171 BREW BASKET ASSY., 13 X 5, DIA HOLE 0.218" (SEE FIG. 6)   
					ADDITIONAL PARTS FOR CBS-2031s, NOT SHOWN ON DRAWING   
					1 
					1 
					102207 ASSEMBLY, REED SWITCH   
					101160 ASSEMBLY, BREW BASKET LOCK. 120 VAC   
					EXPORT   
					220V ONLY   
					1 
					1 
					101174 ASSEMBLY, BREW BASKET LOCK. 220 VAC   
					57044 VALVE, BYPASS LEFT 120 VAC   
					57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					EXPORT   
					220V ONLY   
					EXPORT   
					1 
					57077 VALVE, BYPASS LEFT 220 VAC   
					57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					220V ONLY   
					57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   
					101175 BREW BASKET ASSEMBLY, 13 x 5, DIA. HOLE 0.280 (SEE FIG. 7)   
					1 
					14   
				Figure 2 – CBS-2031e / CBS-2031s Tank Assembly   
					DWG 104028-A   
					ITEM #   
					QTY   
					PART # DESCRIPTION   
					1 
					1 
					004042 WELDMENT TANK CBS-2031e   
					2 
					3 
					1 
					1 
					3 
					3 
					1 
					1 
					1 
					2 
					2 
					2 
					2 
					1 
					1 
					1 
					2 
					2 
					8 
					24002 O-RING, TANK COVER   
					102013 ASSEMBLY, TANK COVER   
					4 
					31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD   
					83042 WASHER, .875"OD X .562"ID, FLAT   
					31081 PLUG, HEX HEAD 1/4" MPT   
					5 
					6 
					7 
					25098 FITTING, COMPRESSION MALE CONNECTOR   
					31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT   
					107025 HEATER ASSY., 1500W/120VAC   
					107019 HEATER ASSY., 1700W/120VAC   
					107020 HEATER ASSY., 2300W/120VAC   
					107021 HEATER ASSY., 3000W/240VAC   
					31116 LOCKNUT 1/8 STRAIGHT PIPE THREAD   
					83041 WASHER, .812"OD X .412"ID, FLAT   
					31005 FITTING, 90 ELBOW, 1/4 HOSE ID X 1/8 MPT   
					03332 BRACKET 2, ONE SHOT THERMOSTAT   
					53064 THERMOSTAT, SINGLE SHOT,TRIAC   
					83011 WASHER, #6 SCREW SIZE, INTERNAL   
					8 
					9 
					9 
					9 
					EXPORT   
					220V ONLY   
					9 
					10   
					11   
					12   
					13   
					14   
					15   
					15   
				16   
					17   
					18   
					19   
					20   
					21   
					22   
					23   
					24   
					25   
					26   
					27   
					28   
					8 
					1 
					1 
					1 
					3 
					1 
					1 
					2 
					1 
					1 
					2 
					2 
					1 
					84001 NUT, HEX, #6-32 MACHINE SCREW   
					31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD   
					83044 WASHER, 1.125"OD X 0.750"ID, FLA   
					31071 FITTING, 1/2 HOSE ID X 3/8" MPT   
					31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD   
					31152 VALVE, COMPR 3/8 TUBE OD X 1/4 MPT   
					13055 TUBE, VALVE DRAIN , 3/8" OD X .035"TH X 1.5" LG   
					31128 FITTING, 90 ELBOW, 3/8 HOSE ID X 1/4 MPT   
					31027 FITTING, COMPR 90 MALE ELBOW, 3/8 TUBE OD X 1/4 MPT   
					13072 OUTLET, INSIDE TANK HOT WATER   
					03297 SINK, HEAT FOR 40A TRIAC   
					59008 TRIAC 40A, 600V   
					84007 NUT, 3/4-16 HEX JAM   
					16   
				Figure 3 – CBS-2032e / CBS-2032s Main Assembly   
					DWG 101196-D   
					ITEM #   
					QTY   
					PART # DESCRIPTION   
					1 
					1 
					001050 WELDMENT, CBS-2032e   
					2 
					3 
					1 
					1 
					1 
					2 
					2 
					1 
					1 
					1 
					2 
					1 
					1 
					1 
					1 
					2 
					1 
					104027 ASSEMBLY, TANK CBS-2032e (SEE FIG. 4)   
					22041 INSULATION TANK FRONT CBS-2032e   
					22042 INSULATION TANK BACK CBS-2032e   
					102080 ASSEMBLY, SMALL SPRAY HEAD, 120V (SEE FIG 5)   
					102158 ASSEMBLY, SMALL SPRAY HEAD, 220V (SEE FIG 5)   
					102189 ASSEMBLY, POWER BRACKET, CBS-2000e   
					52026 CIRCUIT BREAKER, 5A   
					4 
					5 
					EXPORT   
					220V ONLY   
					5 
					6 
					6 
					6 
					58054 SWITCH, PUSH BUTTON   
					7 
					86032 BUSHING, SNAP, 1" MOUNTING HOLE DIA   
					52050 TERMINAL BLOCK   
					8 
					9 
					65002 CONNECTOR, COPPER LUG   
					10   
					11   
					12   
					13   
					402023 HARNESS, LOW AMP, ELECTRICAL, CBS-2032e, TWO HEATERS   
					402032 HARNESS, HIGH AMP, TWO HEATER WIRE SET CBS-2032e   
					29021 SPACER, #8 SCREW SIZE   
					102192 ASSEMBLY, HOT WATER VALVE, 120VAC   
					17   
				13   
					13   
					57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					102193 ASSEMBLY, HOT WATER VALVE, 220VAC   
					EXPORT   
					220V ONLY   
					EXPORT   
					1 
					13   
					13   
					14   
					15   
					16   
					17   
					17   
					18   
					19   
					20   
					20   
					21   
					22   
					23   
					24   
					25   
					26   
					26   
					27   
					28   
					29   
					30   
					31   
					32   
					33   
					34   
					35   
					36   
					37   
					38   
					39   
					40   
					41   
					42   
					43   
					44   
					45   
					46   
					47   
					48   
					49   
					50   
					51   
					52   
					53   
					54   
					55   
					57   
					57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   
					83051 WASHER, #8 SCREW SIZE, FLAT   
					220V ONLY   
					2 
					7 
					17   
					1 
					1 
					4 
					3 
					1 
					1 
					4 
					1 
					1 
					1 
					3 
					1 
					1 
					1 
					1 
					1 
					4 
					1 
					1 
					1 
					1 
					2 
					2 
					1 
					1 
					1 
					1 
					1 
					4 
					2 
					5 
					1 
					1 
					2 
					1 
					1 
					1 
					1 
					10   
					1 
					1 
					1 
					2 
					83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE,   
					84002 NUT, HEX, #8-32 MACHINE SCREW   
					108002 SWITCHING/CONTROL BOARD, 8 KEYS, D2P (CBS-2032e ONLY)   
					108038 SWITCHING/CONTROL BOARD, 8 KEYS, D2P (CBS-2032s ONLY)   
					15007 STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2"   
					29007 NUT, #4-40 KNURLED THUMB   
					51042 BOARD, POWER SUPPLY-120VAC   
					EXPORT   
					220V ONLY   
					51055 BOARD, POWER SUPPLY-220VAC   
					29019 SPACER, .25" HEX x 1" LG., FEM, #4-40 THREAD   
					002065 WELDMENT, HOT WATER FAUCET   
					33007 LOCKNUT, 7/16 STRAIGHT PIPE THREAD   
					45078 OVERLAY CBS-2032e   
					73029 LEG, THERMOPLASTIC, 2.50"(63mm)   
					57006 FILL VALVE, S-53 120VAC   
					EXPORT   
					220V ONLY   
					57017 FILL VALVE, S-53 220VAC   
					24012 GASKET, S-53 FILL VALVE   
					31078 FITTING, S-53 FILL VALVE INLET   
					03074 BRACKET, S-53   
					82020 SCREW, S-53 FILL VALVE   
					31031 FITTING, 90 MALE ELBOW, 3/8 TUBE OD X 3/8 MPT   
					86040 CONNECTOR, CABLE CLAMP, 3/4"   
					102190 ASSEMBLY, DIGITAL TEMP. PROBE, 5.0" LG.   
					102139 ASSEMBLY, WATER LEVEL PROBE, CBS-2030'S   
					102195 ASSEMBLY, BUMPER, 2030e   
					25056 TUBE, 3/4"OD X 1/2"ID X 4"LG, BREW   
					25064 TUBE, 5/8"OD X 3/8"ID X 6.5"LG. HOT WATER   
					25055 TUBE, 5/8"OD X 3/8"ID X 12"LG DRAIN   
					25057 TUBE, 5/8"OD X 3/8"ID X 14 1/2"LG, COLD WATER   
					25058 TUBE 5/8"OD X 3/8"ID X 2.5"LG, HOT WATER FAUCET   
					25059 TUBE, 5/16"OD X 3/16"ID X 9 1/4"LG VENT   
					86038 CLAMP, HOSE, .670"-.780" DIA RANGE   
					86020 CLAMP, HOSE, .875"-.750" DIA RANGE   
					86007 CLAMP, HOSE, .593"-.656" DIA RANGE   
					25102 TUBE, 1/4"OD X 1/8"ID X 20" LG VENT HOT WATER VALVE   
					44004 LABEL GROUND   
					44024 LABEL, WARNING-HIGH VOLTAGE   
					01479 COVER, TOP CBS-2032 & 42   
					01463 COVER, UPPER BASE CBS-2032e   
					401219 WIRING DIAGRAM, CBS-2032e, 1PH, 3 WIRE + GR, 2 HEATERS   
					102191 ASSEMBLY, RIGHT COVER CBS-2030's   
					82053 SCREW, # 6-32 X 1/2" TRUSS HD PH   
					46027 LABEL, SPRAY HOUSING   
					46029 LABEL, POWER SWITCH   
					41016 LABEL, EXTRACTOR   
					101171 BREW BASKET ASSY., 13 X 5, DIA HOLE 0.218" (SEE FIG 6)   
					ADDITIONAL PARTS FOR CBS-2032s, NOT SHOWN ON DRAWING   
					2 
					101160 ASSEMBLY, BREW BASKET LOCK. 120 VAC   
					EXPORT   
					220V ONLY   
					2 
					101174 ASSEMBLY, BREW BASKET LOCK. 220 VAC   
					2 
					1 
					102207 ASSEMBLY, REED SWITCH   
					57043 VALVE, BYPASS RIGHT 120 VAC   
					57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					EXPORT   
					220V ONLY   
					1 
					57076 VALVE, BYPASS RIGHT 220 VAC   
					18   
				EXPORT   
					220V ONLY   
					57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   
					83051 WASHER, #8 SCREW SIZE, FLAT   
					84030 LOCKNUT, #8-32 SCREW SIZE, HEX THIN NYLON INSERT   
					57044 VALVE, BYPASS LEFT 120 VAC   
					6 
					4 
					1 
					57047 VALVE, DSV-11, 120 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					EXPORT   
					220V ONLY   
					EXPORT   
					1 
					57077 VALVE, BYPASS LEFT 220 VAC   
					57071 VALVE, DSV-11, 220 VAC (COIL, DIAPHRAGM, SPRING, & PLUNGER)   
					220V ONLY   
					57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   
					101175 BREW BASKET ASSEMBLY, 13 x 5, DIA. HOLE 0.280 (SEE FIG. 7)   
					1 
					19   
				Figure 4 – CBS-2032e / CBS-2032s Tank Assembly   
					DWG 104027-A   
					20   
				ITEM #   
					QTY   
					PART # DESCRIPTION   
					1 
					1 
					4043 WELDMENT TANK CBS-2032e   
					2 
					2 
					1 
					1 
					1 
					3 
					2 
					2 
					2 
					2 
					2 
					8 
					8 
					2 
					3 
					1 
					1 
					1 
					1 
					3 
					1 
					1 
					2 
					1 
					1 
					1 
					1 
					2 
					107021 HEATER ASSY., 3000W/240VAC   
					3 
					31116 LOCKNUT 1/8 STRAIGHT PIPE THREAD   
					83041 WASHER, .812"OD X .412"ID, FLAT   
					31005 FITTING, 90 ELBOW, 1/4 HOSE ID X 1/8 MPT   
					31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD   
					31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD   
					83044 WASHER, 1.125"OD X 0.750"ID, FLA   
					3332 BRACKET 2, ONE SHOT THERMOSTAT   
					3297 SINK, HEAT FOR 40A TRIAC   
					4 
					5 
					6 
					7 
					8 
					9 
					10   
					11   
					12   
					13   
					14   
					15   
					16   
					17   
					18   
					19   
					20   
					21   
					22   
					23   
					24   
					25   
					26   
					27   
					28   
					59008 TRIAC 40A, 600V   
					83011 WASHER, #6 SCREW SIZE, INTERNAL   
					84001 NUT, HEX, #6-32 MACHINE SCREW   
					31071 FITTING, 1/2 HOSE ID X 3/8" MPT   
					83042 WASHER, .875"OD X .562"ID, FLAT   
					31081 PLUG, HEX HEAD 1/4" MPT   
					31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT   
					25098 FITTING, COMPRESSION MALE CONNECTOR   
					84007 NUT, 3/4-16 HEX JAM   
					31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD   
					31027 FITTING, COMPR 90 MALE ELBOW, 3/8 TUBE OD X 1/4 MPT   
					13072 OUTLET, INSIDE TANK HOT WATER   
					31128 FITTING, 90 ELBOW, 3/8 HOSE ID X 1/4 MPT   
					31152 VALVE, COMPR 3/8 TUBE OD X 1/4 MPT   
					13055 TUBE, VALVE DRAIN , 3/8" OD X .035"TH X 1.5" LG   
					24002 O-RING, TANK COVER   
					102013 ASSEMBLY, TANK COVER   
					53064 THERMOSTAT, SINGLE SHOT,TRIAC   
					21   
				Figure 5 – Spray Housing Assembly, 120 VAC, Part # 102080   
					Spray Housing Assembly, 220 VAC, Part # 102158 (EXPORT ONLY)   
					ITEM #   
					QTY   
					4 
					PART # DESCRIPTION   
					1 
					2 
					82112 #8 X 3/4'' PAN HD. PHIL. T.S. 18-8 S.S. SCREW   
					57047 VALVE ASSY., DSV-11, 120 VAC   
					1 
					EXPORT   
					220V ONLY   
					2 
					3 
					4 
					5 
					6 
					1 
					1 
					1 
					1 
					1 
					57071 VALVE ASSY., DSV-11, 240 VAC   
					57073 VALVE REBUILD KIT, DSV11   
					102082 SPRAY HOUSING ASSY.   
					24054 O-RING 4.237” I.D., #156   
					102081 SPRAY PLATE ASSY., 4 7/8" DIA.   
					22   
				NOTE: The round and square brew baskets pictured below are not interchangeable. Use only the   
					type of brew basket that originally came with the brewer.   
					Figure 6 – Brew Basket Assembly, 13” X 5”, Part # 101171 (ROUND)   
					ITEM QTY PART # DESCRIPTION   
					1 
					2 
					3 
					4 
					1 
					2 
					1 
					1 
					9021 WIRE INSERT, 13 X 5   
					82118 HANDLE SCREW   
					23074 BREW BASKET HANDLE, BLACK   
					46011 WARNING LABEL   
					F002 PAPER FILTERS, 13” X 5”   
					500 PER CASE   
					NOT   
					SHOWN   
					COLOR BREW BASKET HANDLES   
					PART # DESCRIPTION   
					23169 BREW BASKET HANDLE, RED   
					23171 BREW BASKET HANDLE, GREEN   
					Figure 7 – Brew Basket Assembly, 13” X 5”, Part # 101175 (SQUARE)   
					ITEM QTY PART # DESCRIPTION   
					1 
					2 
					3 
					5 
					8 
					09022 WIRE INSERT, 13” X 5   
					23117 BREW BASKET HANDLE, BLACK   
					46011 WARNING LABEL   
					82096 HANDLE SCREW   
					1 
					1 
					1 
					1 
					57082 MAGNET   
					PAPER FILTERS, 13” X 5”   
					F002   
					NOT   
					SHOWN   
					500 PER CASE   
					COLOR BREW BASKET HANDLES   
					PART # DESCRIPTION   
					23106 BREW BASKET HANDLE, GREEN   
					23107 BREW BASKET HANDLE, ORANGE   
					23148 BREW BASKET HANDLE, RED   
					23   
				 |