DCS none User Manual

dCS Scarlatti Clock  
Digital Audio Master Clock  
User Manual  
Software Release 1.0x  
June 2008  
© Data Conversion Systems Ltd. 2007-8  
Price UK £8.00 / Euro 12.00  
All rights reserved. No part of this publication may be reproduced, stored in or introduced into a retrieval system,  
or transmitted in any form, or by any means (electronic, mechanical, photocopying, recording or otherwise)  
without the prior written permission of dCS1. Any person who does any unauthorised act in relation to this  
publication may be liable to criminal prosecution and civil claims for damages.  
Information contained in this manual is subject to change without notice, and whilst it is checked for accuracy, no  
liabilities can be accepted for errors.  
1
dCS is Data Conversion Systems Ltd. Company registered in England No. 2072115.  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
CONTENTS  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 3  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
USING THE dCS Scarlatti Clock FOR THE FIRST TIME  
Congratulations on purchasing your dCS Scarlatti Clock.  
Before using your unit, please read this section and the Step by Step Guide. This will enable you to  
set the unit up quickly and safely with your hi-fi system.  
From time to time, dCS will release updated software on CD that you can install yourself using the CD  
Update feature. Please check our web-site occasionally to see if new Scarlatti software is available, or  
consult your dealer.  
What’s in the box?  
Check that the box contains the following items:  
dCS Scarlatti Clock  
Manual and Menu / Setup Guide  
Power cable  
3x BNC cables  
spare fuses  
Notify your dealer as soon as possible if anything is missing or damaged. We suggest that you retain  
the original packaging for possible future use. If this is not possible, replacement packaging can be  
ordered from dCS or our distributors. Details can be found on our web site at www.dcsltd.co.uk.  
The Scarlatti Transport is supplied with a programmed Philips Pronto remote control. If you do not  
have a Scarlatti Transport in your system, a programmed Pronto can be ordered direct from dCS as an  
optional extra.  
Safety Notice  
Your dCS Scarlatti Clock contains no user serviceable parts. DO NOT attempt to open the case as  
there are potentially dangerous voltages present inside. In the event of the unit developing a fault,  
please contact your dealer in the first instance.  
Mains Voltage Setting  
Before connecting the power cable to the unit for the first time, please check that it has been set to the  
correct operating voltage for your mains supply. The unit’s voltage setting is shown on the label  
beneath the mains inlet on the rear panel. If this does not match your local supply voltage, DO NOT  
attempt to use the unit. Contact your dealer to have the unit reset. Using the unit with the wrong mains  
setting for your local supply may result in serious damage to the unit and will invalidate the warranty.  
Do not attempt to reset the voltage yourself.  
Power Cables  
If you wish to use a power cable other than the one supplied, please ensure that it is a good fit to the  
mains inlet, and is not so heavy and inflexible as to place strain on the mains inlet.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 4  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
Mains Regenerators  
We do not recommend the use of mains regenerators. However, if you do wish to use a mains  
regenerator with variable voltage and frequency, we recommend that you set the voltage to match  
your local voltage and the frequency to either 50Hz or 60Hz ONLY.  
Damage caused to your Scarlatti Clock by misuse of a mains regenerator or by a  
malfunctioning mains regenerator is not covered by the warranty.  
!
Positioning the unit  
Units in the Scarlatti range are designed to be mounted on separate shelves of a rack and must NOT  
be stacked directly on top of each other. Place each unit on a firm, vibration free base, allowing  
convenient connection to the other parts of your system. To prevent overheating, we recommend that  
you leave some free space around the unit to allow for ventilation.  
Disposal at end-of-life  
The symbol indicates that this product should not be treated as normal  
household waste. It should be recycled, so please take it to an approved  
collection facility.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 5  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
STEP-BY-STEP GUIDE  
This section guides you through setting up the unit for basic operation.  
Preliminaries  
The Menu / Setup Guide sheet details the menu structure and details the two most common set-ups.  
For all of the Word Clock Outputs and the Ref Input, use 75Ω coax cables fitted with BNC plugs.  
Connect the power cable supplied to the power inlet on the Clock rear panel, plug the other end into a  
convenient power outlet.  
Please do not use an excessively heavy or inflexible power cable as this may damage  
the power inlet connector.  
!
Press the Power button and wait about 30 seconds while the Clock configures itself. The display will  
show in sequence: Scarlatti and either 44.1Hz or 48kHz.  
If the unit is likely to be set in an unfamiliar state, you can reset it as follows:  
Press the Menu button, press the button once, then the Menu button again to display the Clock  
Settings menu. Press the button a few times to highlight the Factory Reset menu page. Press the  
Menu button and wait a few seconds while the unit resets itself.  
The GOLDEN RULES for using a Master Clock  
The source equipment MUST be locked to the Master Clock.  
If it is not, you will either have locking difficulties or hear occasional clicks and the advantages of  
using the Clock will be lost.  
Some non-dCS CD transports, DAB radios and other equipment do not have a Word Clock Input  
and so CANNOT be locked to a Master Clock.  
The clock frequency MUST match the sample rate(s) used in the system.  
If it does not, the system cannot lock and the DAC may remain muted. Please check the  
manuals for the equipment used in your system.  
When the Scarlatti Clock is set to 44.1kHz, it may be used with DSD-based systems, CD  
systems without an upsampler running at 44.1kHz or CD systems upsampling to 88.2kS/s or  
176.4kS/s Dual AES.  
When the Scarlatti Clock is set to 48kHz, it may be used with a DVD player or DAT recorder  
fitted with a Word Clock Input running at 48kS/s, or upsampling to 96kS/s Dual AES or 192kS/s  
Dual AES.  
To make best use of the Scarlatti Clock, all the digital audio units in the chain should be locked to it.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 6  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
Connecting the system for DSD  
Most owners will use the Scarlatti Clock to clock a Scarlatti stack at 44.1kHz.  
If necessary, use the FREQUENCY button to set the Clock to 44.1kHz.  
Connect one of the Clock outputs to the Word Clock inputs of the transport and the DAC.  
Connect a 1394 cable between the DAC and the transport. Select the DAC’s 1394 input.  
The transport will automatically slave to the Clock and display Sync.  
Use the DAC’s SYNC button to set it to WClk.  
Connect the DAC’s Analogue Outputs to a power amplifier or preamplifier.  
Set the DAC Volume control to a suitable level and play a disc.  
Set the Clock’s DITHER feature on or off as you prefer.  
Scarlatti Transport  
DIGITAL  
CH1  
SDIF  
CH2  
SUC  
OUTPUTS  
IN ---- WORDCLOCK --- OUT  
AES 1  
AES 2  
RCA  
BNC  
TOSLINK  
1394  
Scarlatti Clock  
50/60 Hz, 30W  
1394  
~
WORDCLOCK OUTPUTS  
REF. IN  
FUSE  
T 500mA L  
1
2
3
4
5
6
7
8
SUC  
Scarlatti DAC  
RCA 1  
1394  
50/60 Hz, 50W  
DSD/SDIF  
LEFT  
CH 1  
CH 2  
TOSLINK  
ANALOGUE OUTPUTS  
DIGITAL INPUTS  
~
SPDIF  
RCA 2  
BNC  
FUSE  
T 500mA L  
OUT  
LEFT  
RIGHT  
AES 1  
AES 2  
IN  
SUC  
RIGHT  
WCLK  
L
R
L
R
Balanced - or - Unbalanced  
Analogue Outputs  
To pre- or power amplifier inputs  
Figure 1 – Using the Scarlatti Transport, DAC and Clock together  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 7  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
Connecting the system for Dual AES  
Owners with an Upsampler may prefer to use it to run the DAC at 176.4kS/s.  
If necessary, use the FREQUENCY button to set the Clock to 44.1kHz.  
Connect one of the Clock outputs to the Word Clock inputs of the transport, the Upsampler and the  
DAC.  
Connect an AES cable between the transport’s AES output and the Upsampler’s AES input, select  
that input.  
Set the Upsampler to 176.4kS/s.  
Connect the Upsampler’s AES1 & 2 outputs to the DAC’s AES1 & 2 inputs and select the DAC’s  
Dual AES input. (It may be necessary to turn Dual AES mode on in the menu.)  
The transport will automatically slave to the Clock and display Sync.  
Set the Upsampler to sync to the external word clock.  
Use the DAC’s SYNC button to set it to WClk.  
Connect the DAC’s Analogue Outputs to a power amplifier or preamplifier.  
Set the DAC Volume control to a suitable level and play a disc.  
Set the Clock’s DITHER feature on or off as you prefer.  
Using an External Reference  
If you have a GPS receiver or an atomic clock with a 10MHz output, you can lock the Scarlatti Clock to  
it. These sources are even more accurate than the Scarlatti Clock, but note that low jitter and stability  
are more important than absolute accuracy.  
Connect your system for DSD or Dual AES as you prefer.  
Use another BNC cable to connect the 10MHz output from the external reference to the Scarlatti  
Clock‘s Ref In connector.  
Open the Clock’s menu and set the Coupling menu page to Bipolar. The Clock should lock to the  
external reference and display Sync.  
Set the DAC Volume control to a suitable level and play a disc.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 8  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
FRONT PANEL  
DITHER  
POWER  
DISPLAY  
FREQUENCY  
MENU  
Sc arlatti  
dCS  
A B C  
D
E F G  
Figure 2 – Front panel  
POWER Button  
To switch on, ensure the rear panel switch is set to I and press the POWER button (A) on the front  
panel once. Note that the unit cannot be turned on from the remote control.  
To set the unit to sleep mode, press the POWER button once. The main display will turn off, the clock  
outputs will mute and the LED over the button will light. Press again to return to normal operation.  
To switch off, hold down the POWER button for about 5 seconds until Power Down appears on the  
display, then release it.  
When the menu is open, press the POWER button to close the menu.  
DISPLAY Button  
Press the DISPLAY button (B) to turn the main display off and on. When the display is off, the LED  
over the button will light to warn you that the unit is running.  
When the menu is open, the DISPLAY button changes to the button, used to page backwards  
through the menu.  
DITHER Button  
Press the DITHER button (C) to turn the Dither feature on and off. This dithers the clock edges in a  
controlled way to exercise the phase-locked–loops in the source and DAC. Try it and decide for  
yourself whether you prefer Dither on or off.  
When the menu is open, the DITHER button changes to the button, used to page forwards through  
the menu.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 9  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
Display  
In normal use, the clock frequency is shown at the top of the display (D), for example:  
The icons at the bottom show the current settings or operating conditions. From the left, these are:  
Temperature stabilised, if the icon is displayed.  
Dither on, if this icon is displayed.  
Coupling menu setting (TTL is shown, the alternative is Bipolar).  
If the unit is locked to an external reference, SYNC is displayed instead. If an external reference is  
connected but the unit cannot lock to it, SYNC is displayed greyed out.  
Details of the menu displays are shown in the Menu section on page 12.  
FREQUENCY Button  
Use the FREQUENCY button (E) to set the clock frequency to either 44.1kHz or 48kHz. The usual  
setting is 44.1kHz.  
MENU Button  
Press the MENU button (F) to open the menu, select menu pages and change settings. See the Menu  
section on page 12 for information on using the menu features.  
Remote Control Receiver  
Aim the remote control handset towards the receiver (G) for best sensitivity.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 10  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
REAR PANEL  
50/60 Hz, 30W  
1394  
~
WORDCLOCK OUTPUTS  
REF. IN  
FUSE  
T 500mA L  
1
2
3
4
5
6
7
8
SUC  
G
H
I
J
K L M  
Figure 3 – Rear panel  
Word clock is used for synchronisation only, it does not carry digital data.  
Word Clock Outputs  
The unit has eight identical Word Clock Outputs (G), all of which carry standard word clock at either  
44.1kHz or 48kHz.  
Ref Input  
The Ref In connector (H) allows the unit to be locked to an accurate external reference, such as an  
atomic clock or a GPS clock. With the Coupling menu page set to TTL, the unit will lock to an external  
word clock at 32, 44.1, 48, 88.2 or 96kHz. With the Coupling menu page set to Bipolar, the unit will  
lock to a 10MHz reference.  
As the Scarlatti Clock is a grade 1 master clock, there is nothing to be gained by locking it to a less  
stable or less accurate reference!  
1394 Interface  
There is provision for fitting an IEEE 1394 interface (I), which may be added at a later date. As a  
Master Clock does not generate or accept digital data, this will be used for control purposes only.  
SUC Connector  
The SUC connector (J) is an RS232 interface, primarily used to remotely control the unit during  
automated testing. Please contact dCS for advice on using this interface with a household automation  
system. Note that we recommend using infra-red remote control instead.  
Mains inlet  
Power is connected via a standard IEC320 connector (K), protected by a fuse (L) and isolated by a 2-  
pole power switch (M).  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 11  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
THE MENU  
Press "Step >" to move along the Menu, press "< Step" to move back.  
Press "Select" to set a menu option or change options.  
MENU  
Unit  
information  
Information  
Version  
Contact  
CDUpdate  
Displays the loaded  
software issues and  
serial number  
Starts software  
update from a dCS  
CD  
Displays dCS  
contact details  
Displays the unit  
status  
Clock Settings  
Coupling  
Factory Reset  
Sets the External  
Input to detect TTL  
or bipolar (AC).  
Restores standard  
factory settings  
Display  
Settings  
Bright  
Contrast  
Test Display  
Sets the display  
brightness  
Adjusts the display  
contrast.  
Runs a display test  
routine  
Figure 4 – The menu sequence  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 12  
English version  
   
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
Using the Menu  
The menu gives the user access to a range of additional features. It also allows new features and  
performance enhancements to be added at a later date by software upgrades.  
The menu is controlled by four buttons.  
Press the MENU button to open the menu or select a setting.  
Press the button to page forward through the menu.  
Press the button pages backward through the menu.  
Press the POWER button to close the menu or just wait 5 seconds.  
Alternatively, use the remote control to access the menu.  
Use the Menu Guide sheet to help you find the right menu.  
Each unit in the range has either three or four top-level menu pages:  
The INFORMATION menu gives software issues, serial number, contact details and unit  
set-up details.  
Each model has a different SETTINGS menu, which allows you to set some features that  
are not directly accessible from the front panel.  
The DISPLAY SETTINGS menu is used to adjust and test the display.  
The SIGNAL GENERATOR menu (on the Transport and DAC only) contains test and  
set-up routines.  
Use the button to move the highlight to the menu you want, then press the MENU button to select it.  
The next menu level down is displayed. Use the button to move the highlight to the menu page you  
want, then press the MENU button to display the information or change the setting.  
Select the exit icon  
to go back to the previous menu level.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 13  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
INFORMATION Menu  
The Version page displays the software versions loaded in the unit and the full serial  
number. Please have this information ready if you contact your dealer for any reason.  
The Contact page displays dCS web-site URL, email address, telephone and fax  
numbers. If you have any difficulty, please contact your dealer for help first.  
The Clock Information page reports the status of the unit:  
Output frequency ....kHz  
Coupling TTL / Bipolar  
Dither on / off  
Temperature stable / unstable  
Master / Slave mode  
Input frequency ...kHz / ...MHz / unlocked  
Temperature ....°C  
Use the ← → buttons to scroll down the list and the MENU button to exit.  
The CD Update feature allows you to load new software into your system from either a  
Scarlatti transport or any STANDARD CD player or transport. Note that some non-Red-  
Book CD transports change the digital data and cannot be used to download new  
software. Please follow the instructions supplied with the update CD carefully.  
CLOCK SETTINGS Menu  
The Coupling menu page sets the External Input to accept either an AC coupled Bipolar  
reference (generated by a GPS receiver, for example) or a Word Clock at TTL levels.  
The Factory Reset menu page resets the unit to standard settings. These are:  
Output Frequency to 44.1kHz.  
Dither to Off.  
Coupling to TTL.  
Display to On.  
Brightness to maximum.  
Contrast to 60%  
DISPLAY SETTINGS Menu  
Set the display Brightness to a comfortable level.  
Set the display Contrast to a comfortable level.  
Runs a Display Test routine, which flashes all the indicators and the main display.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 14  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
SPECIFICATION  
Clock type  
Class 1 Master Clock with dual VCXO, temperature compensated.  
44.1kHz or 48kHz.  
Clock Frequencies  
Clock Accuracy  
Better than +/- 1ppm when shipped (guaranteed for 12 months from  
shipping), typically +/-0.1ppm when shipped and stabilised.  
Word Clock Outputs  
Reference Input  
8 independently buffered outputs on 75Ω BNC connectors, all carry the same  
clock frequency.  
External Reference Input on 1x 75Ω BNC connector. Accepts word clock  
(with the Coupling menu page set to TTL) or AC coupled signals (with the  
Coupling menu page set to Bipolar) at 32kHz, 44.1kHz, 48kHz, 88.2kHz,  
96kHz, 1MHz, 5MHz or 10MHz. Lock range is +/-300ppm.  
Start-up time  
Typically 1 minute to rated accuracy.  
Size and weight  
460mm (18.0”) long x 405mm (15.9”) deep x 73mm (2.9”) high. Allow extra  
depth for cable connectors.  
9.8kg (21.6lbs).  
Power requirements  
Internally set to either 100, 115/120, 220 or 230/240V AC, 49 – 62Hz.  
Power consumption: 8W typical, 12W maximum.  
These specifications are subject to change without notice.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 15  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
MAINTENANCE AND SUPPORT  
Service and Maintenance  
dCS audio products are designed not to need regular maintenance, and contain no user serviceable  
parts apart from the mains fuse. If your unit is damaged in any way, please contact your dealer.  
Replacing a Blown Mains Fuse  
There is a mains fuse below the power inlet, accessible from the outside of the unit. If the fuse blows,  
it may be changed by the user. The current consumption of the unit is very low, so it only blows if  
power surges occur, or there is a fault in the unit. Usually power surges cause no other damage, but if  
the fuse blows repeatedly on replacement, some other damage will have been done and the unit must  
be returned to dCS for repair.  
Fuse type: 20 x 5mm T0.5 amp L fuse  
If the fuse should fail, it is essential that it is replaced with one of the same type and  
rating. Failure to do so could result in damage to the unit, risk of fire or electric shock and  
will invalidate the guarantee.  
!
Referring to the diagram below, remove the power cable, use a small flat bladed screwdriver to pry up  
the tab on the fuse carrier (A) and pull it out. Push the blown fuse out of the clip in the carrier (B) and  
dispose of it. Fit a new fuse in the clip (C) and push the carrier back into the unit so that it clicks home.  
Spare fuses are provided with the unit.  
B
A
C
Cleaning the case  
The front and back panels of your dCS equipment are machined from very high grade aluminium.  
Great care has been taken to create the finish of the aluminium throughout the engineering process  
from the raw solid material to the finished piece.  
To remove loose dust or finger marks from the case, we recommend that you use a clean, dry, lint-  
free cloth.  
To restore the finish on the front and back panels, we recommend applying small quantities of a  
lanolin based cleaner, using a clean, dry, lint-free cloth and then wiping off. Do not allow lanolin to  
collect around the buttons.  
Small amounts of glass cleaner containing ammonia may be used to clean other surfaces, but avoid  
spraying onto the connector contacts.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 16  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
Limited Warranty  
General  
dCS warrants this product against defects in materials and workmanship for a period of 3 years from  
the date the unit was originally shipped from dCS. During the warranty period, dCS will repair or, at our  
absolute discretion, replace a faulty product. Warranty repairs must only be carried out by dCS or our  
authorised service agents. Please contact your dealer if your unit requires service.  
Your dealer should have completed on your behalf an Owner Registration form at the time of sale  
and returned it to dCS. On receipt of the Owner Registration form, dCS will add your contact details to  
our customer database. dCS will use this information for warranty purposes only, we will not contact  
you directly for reasons relating to sales and marketing.  
This warranty applies to the original owner.  
Warranty Exclusions  
The Warranty does not cover wear and tear.  
The Warranty on this product will be void if:  
the product is misused in any way.  
any unauthorised modifications or repairs are carried out.  
the product is not used in accordance with the Operating Conditions stated in this manual.  
the product is serviced or repaired other than by dCS or our authorised service agents.  
the product is operated without a mains earth (or ground) connection.  
the unit is returned inadequately packed.  
dCS reserve the right to apply a service charge if a product returned for warranty repair is found to be  
operating correctly, or if a product is returned without a returns number being issued.  
This warranty covers parts and labour only, it does not cover shipping charges or tax/duty.  
Our dealers or distributors are NOT authorised to extend the terms of this warranty, dCS cannot accept  
responsibility for any attempt to do so.  
Products re-sold by dCS on a “used” basis may be subject to reduced warranty terms.  
Obtaining Service  
Should you encounter a problem, contact your authorised dCS dealer for advice, quoting the model,  
the full serial number, software version number, and giving a detailed description of the fault. Your  
dealer will advise you fully on actions that need to be taken. When returning a unit, the original  
packaging should be used to avoid transit damage. Replacement packaging sets may be purchased  
from dCS.  
During the Warranty period, there will normally be no charge for parts or labour.  
Operating Conditions  
The supply voltage must remain within +/-10% of the A.C. voltage specified on the back panel.  
The supply frequency must be in the range 49Hz to 62Hz.  
Ambient temperature range: 0°C (32°F) to 40°C (104°F), non-condensing.  
Do not install the unit near heat sources such as radiators, air ducts, power amplifiers or direct  
strong sunlight.  
If in doubt, the easy test is – the unit is happy to work anywhere a human is.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 17  
English version  
 
dCS Scarlatti Clock User Manual  
Software Issue 1.0x  
June 2008  
If you need more help  
In the first instance, you should contact your dealer. If they cannot resolve the issue, contact your  
national distributor.  
Manufactured by:  
dCS Ltd  
Mull House  
Great Chesterford Court  
Great Chesterford  
Saffron Walden CB10 1PF  
UK  
This user manual may be downloaded free of charge from our web-site.  
A bound copy of this manual may be ordered from dCS.  
Software History  
dCS products make extensive use of software configurable chips – FPGAs and DSPs. This gives us  
the ability to update our products to add extra features, update digital interface standards or make  
performance improvements by loading new software. Occasionally, a hardware update may be  
necessary also to increase the “capacity” of the electronics, add extra connectors or extra front panel  
controls.  
Please note that not all software updates make an earth-shattering change. You should have a clear  
idea of what you expect to gain before updating to the latest issue. We recommend that you keep your  
software up to date. Check the dCS web-site for the latest software updates.  
This manual is for Scarlatti Clock software version 1.0x.  
Issue 1.00 - The first issue.  
Filename: Scarlatti Clock Manual v1_0x.doc  
Page 18  
English version  
 

Motorola TELUS H83XAH6RR4AN User Manual
Motorola MOTOROKR 68000201355 A User Manual
Maxtor D540X 4G User Manual
LG Electronics SAMBA 8575 User Manual
Kenwood DPF 3030 User Manual
JVC SA K51U User Manual
FieldServer Optomux FS 8700 17 User Manual
FieldServer ControlNet FS 8700 24 User Manual
Corsair 700D User Manual
Centon electronic DataStick Bolt 4GBDSB SILVER User Manual