GOURMET HOT BEVERAGE DISPENSER
Models:
ICAP1
ICAP1-P
ICAP-MINI
WHIPPER
WHIPPER MINI
OPERATIONAL MANUAL
Specifications
Installation & Operating Instructions
Adjustments
Care & Maintenance
Trouble Shooting Guide
Wiring Diagram
Parts List
THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH
THE APPLICABLE FEDERAL, STATE, OR LOCAL PLUMBING
CODES HAVING JURISDICTION.
IN ADDITION:
1. A QUICK DISCONNECT WATER CONNECTION OR
ENOUGH EXTRA COILED TUBING (AT LEAST 2X
THE DEPTH OF THE UNIT) SO THAT THE MACHINE
CAN BE MOVED FOR CLEANING UNDERNEATH.
2. AN APPROVED BACK FLOW PREVENTION DEVICE,
SUCH AS A DOUBLE CHECK VALVE TO BE INSTALLED
BETWEEN THE MACHINE AND THE WATER SUPPLY.
Cecilware sells value...
Worldwide.
43-05 20th Avenue, Long Island City, NY 11105 · 718-932-1414
FAX:
· 718-932-7860
NA64A 6/99
INSTALLATION REQUIREMENTS for ICAP1 B LD and WHIPPER B:
THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE APPLICABLE FEDERAL, STATE, OR LOCAL PLUMBING CODES
HAVING JURISDICTION. IN ADDITION:
1. A QUICK DISCONNECT WATER CONNECTION OR ENOUGH EXTRA COILED TUBING (AT LEAST 2X THE
DEPTH OF THE UNIT) SO THAT THE MACHINE CAN BE MOVED FOR CLEANING UNDERNEATH.
2. AN APPROVED BACK FLOW PREVENTION DEVICE, SUCH AS A DOUBLE CHECK VALVE TO BE INSTALLED
BETWEEN THE MACHINE AND THE WATER SUPPLY.
INSTALLATION:
1. Flush inlet water line thoroughly before connecting. If pipe sealant is necessary, teflon tape is commended.
2. Connect water line to the 1/4” flare fitting located at rear of the unit. A shutoff valve in the water supply line is advisable.
3. Check that heater switch is in the OFF position. Switch is located below DOOR ASSEMBLY lower right side corner.
4. Turn on water. Check water line and fittings for leaks.
5. Plug the power cord into a grounded 120 volt, 60 Hz 15 Amp outlet, Single use. Press and hold Rinse Button until water
flows through mixing chamber. It will take 2 to 4 minutes to fill the tank.
6. Fill hopper with DRY* powdered cocoa mix or cappuccino product. See filling instructions.
7. Turn heater switch on and allow 10 to 15 minutes for water to heat.
8. Push on Dispensing Button and check the operation of the hopper. A grinding noise will be heard if not properly engaged.
Go to Troubleshooting Guide.
9. Push on Dispensing Button and check the operation of the mixing chamber (for ICAP1 & Whipper ).
A scratching noise will be heard if whipper blade is not properly aligned. Go to Troubleshooting Guide.
10. Push Dispensing Button and check drink taste.
If adjustments are needed, see “Adjustments”.
DISPENSER OPERATION
FILLING
1. Open Front Door.
2. Lift Top Cover.
3. Fill hopper to desired level with DRY*
Powdered cocoa mix or cappuccino.
Do not overfill or pack product down when filling.
4. Close Top Cover and Door.
DISPENSING
1. Place cup under mixing chamber spout.
2. a) For Manual Units (without Timer):
Press and hold push button until cup is approximately 2/3 full.
b) For Automatic Units (with Timer):
Press and release push button. Cup will fill to size set on Timer.
3. Remove cup when flow from mixing
chamber has stopped completely.
*Moist product will clog hopper and the unit will not operate
properly.
Illustration No. 2 – (ICAP 1 B LD & WHIPPER B shown)
3
START UP INSTRUCTIONS FOR ICAP1 POUROVER CAPPUCCINO DISPENSER – see ill. 3
I. INSTALLATION INSTRUCTIONS
This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction.
In addition:
1.
A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine
can be moved for cleaning underneath.
2.
An approved back flow prevention device, such as a double check valve to be installed between the machine and the wa-
ter supply.
The ICAP1 POUROVER beverage dispenser is equipped with a 3/4” Water Inlet Valve (¼" to 3/4” adapter supplied with the
unit) which is located on the right side in the back of the base (when looking at the machine from the front).
HIGHLY RECOMMENDED: A WATER SHUT-OFF VALVE and A WATER FILTER, preferably a combination Charcoal/Phosphate
Filter, to remove odors and inhibit lime and scale build up in the machine.
Note: In areas with extremely hard water, a water softener must be installed in order to prevent a malfunctioning of the equip-
ment and in order not to void the warranty.
After the machine has been unpacked and placed on a counter, pull out the drip tray and splash guard.
It should contain the following: A Set of 4 Adjustable Leveling Legs & Water Inlet Fitting.
Connect the ¼" dia. copper waterline to the ¼" flare water inlet fitting of the valve.
Caution: Do not plug into power outlet yet. Make sure the Heater Switch is OFF (Toggle Down).
II. PRIMING - MANUAL/BOTTLE POUROVER (Toggle UP, Water Selection Switch, on the back panel)
1. Do NOT plug into power outlet yet.
2. Make sure Heater Switch is in the OFF position, located in back of machine.
3. Fill reservoir tank (top) with 2 gallons of water, wait about 3 minutes for water to fill Heating Tank below.
Refill Top Reservoir Tank with another 2 gallons of water. The unit will NOT dispense unless the Top Reservoir Tank is at
least 1/2 full. So keep Reservoir Tank full.
Note: The unit has a Float (item 3, Ill. 8) inside the Reservoir Tank, which stops the machine from dispensing
when the Reservoir Tank is low.
4. Plug into power outlet.
5. Turn Heater Switch ON.
6. Allow 10 to 15 minutes for water to reach dispense temperature of 190°F. Heater Indicator Light (red) goes ON when
heater is on (see lower front panel).
7. Fill hopper with product.
8. Place cup under dispenser.
9. Push and hold Dispense Button (green) until water flows from mixing chamber.
10. Machine is primed and ready to go.
III. PRIMING INSTRUCTIONS FOR ICAP1 POUROVER
PRIMING - AUTOFILL (Toggle Down,Water Selection Switch, on the back panel)
1. Plug into power outlet.
2. Turn Heater Switch ON.
3. Allow 10 to 15 minutes for water to reach dispense temperature of 190°F.
Heater Indicator Light (red) goes ON when heater is on (see lower front panel).
4. Fill hopper with product.
5. Place cup under dispenser.
6. Push and hold Dispense Button (green) until water flow s from mixing chamber
7. Machine is primed and ready to go.
4
IV. POUROVER-PORTABLE BOTTLE OPERATION (Toggle UP, Water Selection Switch, on the back panel)
UNIT CAN BE OPERATED WITH A 3 GALLONS CAPACITY FRESH WATER BOTTLE.
TO OPERATE WITH PORTABLE BOTTLE, proceed AS FOLLOWS:
1. Remove Reservoir Tank Cover.
2. Make sure that Reservoir Tank is only 1/2 full or empty, to prevent water splillage.
To remove excess water push dispense button.
3. Fill bottle with water .
4. Invert bottle into reservoir tank in one motion to minimize spillage.
5. Remove and refill bottle when “REFILL“ light is ON.
NOTE: REFILL LIGHT, ON THE FRONT DOOR PANEL, WILL GO ON, WHICH INDICATES THAT THE WATER TANK MUST
BE REFILLED. WHEN REFILL LIGHT GOES ON, THE UNIT WILL NOT DISPENSE UNTIL TANK IS FILLED WITH WATER.
REFILLING WITH HOT TAP WATER WILL SHORTEN HEAT UP TIME.
V. NORMAL OPERATION
(POUROVER AND AUTOREFILL)
1. Place a 6 oz. or larger cup under dispense nozzle,
then press and hold dispense switch (green) for 6
seconds.
The machine will dispense water at the rate of 1 oz.
per second. Repeat it several times to check for con-
sistent output.
BOTTLE
2. While the tank is heating up, remove the hopper,
load with product and reposition it back in the ma-
chine.
RESERVOIR
COVER
When Heater Light goes OFF, the tank has reached
its brew temperature and the machine is ready to
begin dispensing the first cup of Cappuccino.
RESERVOIR
TANK
VI. WATER FLOW and
DRINK STRENGTH ADJUSTMENTS
THE UNIT IS FACTORY ADJUSTED TO DISPENSE
WATER AND POWDER AT THE RATE OF 1.0 oz/
sec.
TO INCREASE OR DECREASE FLOW, PROCEED AS
FOLLOWS:
1. Remove left side panel and locate Dispense Valve
Flow Adjuster on top of Heated Tank.
2. Locate Flow Adjustment Screw (white) on Dispense
Valve.
3. Rotate Adjustment Screw Counterclockwise to IN-
CREASE flow rate.
WATER FLOW
ADJUSTMENT,
SCREW ON
DISPENSE
INDICATOR
LIGHT- RED
"REFILL TANK
WHEN ON"
DISPENSE
VALVE
4. Rotate Clockwise to DECREASE flow rate.
BUTTON
When making strength adjustments, do not adjust
by more than 1/4 turn at a time, without checking
drink strength (ratio of water to powder).
HOT WATER TANK
DRIP TRAY
Illustration No. 3 – ICAP 1 B LD POUROVER
5
DRINK STRENGTH ADJUSTMENTS
NOTE: The unit has been factory preset to deliver water at 1 oz. per second
A. TO ADJUST PRODUCT THROW (ILL # 4)
1. Open Door Assembly and remove Steam Deflector
by pulling it forward.
2. To make adjustment use a screwdriver with 1/2 inch
wide blade. Engage product adjuster as shown below
and turn as follow.
3. Turn clockwise to increase drink strength or
counter-clockwise to reduce it.
Check drink strength after every half a turn.
If after maximum adjustment, drink taste is not as
desired proceed to adjust the water flow according to
procedure B below.
Illustration No. 4 – Product adjuster
4. Re-install Steam Deflector.
B. TO ADJUST WATER FLOW RATE (ILL. # 5)
1. Remove right hand side cover of the unit.
(looking at the unit from the front)
2. Locate Flow Adjustment Key inside unit mounted
above water valve.
3. Engage Flow Adjustment Key into Flow Controller
and rotate counterclockwise to decrease
and clockwise to increase drink strength.
When making strength adjustments, do not turn
Adjustment Key more than 1/8” at a time without
checking drink strength.
4. Return Adjustment Key back into keyholder.
If after maximum adjustment, drink taste is still not
strong as desired, take auger spring out of the hopper and re-
move the product adjuster.
Illustration No. 5 – Water Inlet Valve
C. DRINK SIZE ADJUSTMENT (ILL. # 6)
(AUTOMATIC UNITS - WITH TIMER)
1. Remove right side panel.
2. Turn knob on Timer right to increase or left to decrease drink size.
The number 6 on the Timer indicates approximate drink size at a
factory setting of 1 oz./sec. flow rate.
3. Press push button and check drink size. Repeat if
necessary, until desired drink size is dispensed.
4. Replace the side panel.
Illustration No 6 - Timer
6
CLEANING INSTRUCTIONS
ICAP1 B LD (with Lit Door)
WHIPPER B (without Lit Door)
DAILY:
TOP COVER
1. Wipe exterior of dispenser with a soft damp cloth.
Deflector setup by pulling forward.
CLEANING INSTRUCTIONS
NA62C
2. Disengage Product Hopper by lifting straight up,
while retaining in the upright position.
3. Remove Mixing Chamber by turning Counterclockwise
and pulling forward.
PRODUCT
HOPPER ASS'Y
A. Remove Mixing Chamber Insert by pulling up.
B. Remove Mixing Chamber Extension by pulling down.
STEAM
DEꢀLECTOR
4. Remove Mixer Blade by pulling forward.
PRODUCT SHUTE
MIXING
CHAMBER
INSERT
5. Wash Grill, Mixer Blade, Insert, Extension, and Mixing
Chamber with a mild detergent.
MIXING
CHAMBER
6. Wipe upper compartment with a damp cloth.
7. Replace all parts including Hopper.
HEATER
SWITCH
RINSE
SWITCH
MIXING
CHAMBER
EXTENSION
GRILL
DRIP TRAY
DRIP TRAY BRACKET
8. Dry thoroughly before reloading with product.
MIXER BLADE
MIXING CHAMBER MOUNT
SLINGER DISC
CLEANING INSTRUCTIONS
ICAP MINI B LD (with Lit Door)
MINI WHIPPER B (without Lit Door)
DAILY:
1. Wipe exterior of dispenser with a soft damp cloth.
Deflector setup by pulling forward.
TOP COVER
CLEANING INSTRUCTIONS
NB04A
2. Wash Drip Tray with hot water.
3. 0lush Mixing Chamber by depressing Rinse Button
approximately 10 seconds.
WEEKLY:
HOPPER ASS'Y
NOTE: IN VERY HIGH VOLUME LOCATIONS, THIS
PROCEDURE SHOULD BE DONE TWICE A WEEK.
STEAM
DEꢀLECTOR
PRODUCT GUIDE
1. Open Top Cover, Door Assembly, and remove Steam
Deflector setup by pulling forward.
MIXING
CHAMBER
EXTENDER
RINSE
SWITCH
2. Disengage Hopper by lifting straight up,
while retaining in the upright position.
MIXING
CHAMBER
WING NUT
3. Remove Mixing Chamber by unscrewing wing nuts.
4. Wash all components after removing.
GRILL
DRIP TRAY
DRIP TRAY BRACKET
OPTIONAL
SEAL (GASKET)
HEATER
SWITCH
MIXING CHAMBER PLATE
MIXING CHAMBER SPACER
5. Wipe upper compartment with a damp cloth.
6. Replace all parts including Hopper.
7. Dry thoroughly before reloading with product.
Illustration No. 7
7
TROUBLESHOOTING PROCEDURE
WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any
internal components of the unit. Before any attempt to replace a component be sure to check all electrical
TROUBLE
Light Display does not go on. a) Dispensing unit unplugged
No power b) No power from terminal block
No water when Rinse Switch a) Water supply off
PROBABLE CAUSE
REMEDY
a) Reconnect dispensing unit
b) Check the terminal block for loose wire
a)Turn on water
is depressed
b) Clogged inlet screen (water valve)
b) Disconnect water line and clean inlet screen
No product when Dispense a) No product in hopper
a) Add product if auger spring is moving
b) Engage hopper to auger motor’s gear
Replace damaged coupling if needed
Check connections of motor, relay and/or
switch, if needed replace such component.
d) Clean hopper and dry thoroughly
Button is depressed
b) Auger spring not working
c) Inoperative auger motor
d) Hopper outlet clogged
a) Leaking inlet water valve
Water does not shut off
a) Clean and check all fittings of water valve.
Replace water inlet valve
b) Malfunctioning Timer
c) Inoperative dispense switch
b) Replace Timer (automatic units only)
c) Check switch connections. Replace dispense switch
Drink too strong
Drink too weak
a) Water flow too low
b) Product throw too high
a) No product in hopper
b) Product throw too low
a) Adjust water flow (see To Adjust Water Flow Rate)
b) Adjust product throw (see To Adjust Product Rate))
a) Add product
b) Adjust product throw (see To Adjust Product Rate)
Water drips from mixing
chamber
a) Temperature too high
b) Leaking inlet water valve
c) Too much water in tank’s
a) Adjust the thermostat accordingly
b) Check fittings, if needed replace water valve
c) Remove tank top and clean holes in inner
Cold drink
a) No hot water
a) Allow tank to heat
b) Run out of hot water
c) Tank does not heat up
b) Allow tank to heat after filling
c) Check for loose wire on either thermostat
or heating element. Replace either or
Drink not whipped
a) No whipper blade
a) Replace whipper blade
b) Whipper blade stuck
b) Check blade alignment, if needed replace
blade and mixing chamber
c) Inoperative whipper motor
c) Replace whipper motor
Noise coming from mixing
chamber
Whipper blade not properly aligned
Check blade alignment, if needed replace blade and mix-
ing chamber
Light Display does not go on Defective light bulb and/or ballast.
Check for loose wire or properly plugged light bulb.
Grinding noise coming from Hopper not properly engaged
unit
Check the mating between the auger motor’s gear and
hopper’s coupling
Dispenser repeats cycle.
a) Malfunctioning Timer.
a) Replace Timer (automatic units only)
b) Malfunctioning Dispense Switch
8
DESCRIPTION AND LOCATION Oꢀ COMPONENTS
ICAP1 B LD (with lit door) & WHIPPER B (without lit door)
Illustration No. 8
9
COMPONENTS IDENTIFICATION
ITEM DESCRIPTION
P/N
ITEM DESCRIPTION
P/N
1
2
3
4
5
6
7
8
9
TANK TOP ASSY
SILICONE TUBING
97127
77184
97122
73277
RE81A
97198
20039
97131
G0140
07059
03051
97293
59024
36 SLINGER DISC
37 "O" RING
38 MIXING CHAMBER MOUNT
39 MIXER BLADE
40 MIXING CHAMBER EXTENDER TUBE
41 MIXING CHAMBER
42 MIXING CHAMBER INSERT
43 LAMP HOLDER MOUNTING BRACKET (lit door)
44 BALLAST (for lit door only)
45 PRODUCT SWITCH
46 LAMP SOCKET - LEVITTON ( for lit door only)
47 FLOURESCENT LAMP 9W ( for lit door only)
48 DOOR WELDMENT ASSY - ICAP 1 B LD (w/lit door)
83034
?
DISCHARGE TUBE ASSY
DISCHARGE TUBE BRACKET
NOZZLE BRACKET
TANK BAFFLE ASSY
TANK BAFFLE SEAL
83033
90230
77184
95001
83036
RE52A
CE221
L455C
44496
L024A
RC53Q
TANK CLAMP ASSY
HEATER ELEMENT 1750W 120V
10 WASHER, HEATER ELEMENT
11 NUT HEATER ELEMENT
12 TANK LIMIT
13 HI-LIMIT TEMPERATURE CONTROL
14 ELBOW, MALE 1/8 NPT X 1/4
15 CONTROL THERMOSTAT
16 TOP FRONT COVER
09246
59016
RC42C
K435C
49 AUGER MOTOR BRACKET
50 AUGER MOTOR 115V
51 SUPPORT PLATE F/AUGER MOTOR
52 GEAR AUGER DRIVE MOTOR GEAR, PLASTIC
73272
52037
90209
90208
17 HOSE BARB FITTING
18 ADJ. VALVE ASSY #H5107 NPT
19 HOSE NUT
20 WATER VALVE INLET ASSY
K415A
95101
L477A
44242
58017
58019
B135A
B129A
RE80Q
M034C
92007
53 O RING
54 CARTRIDGE HEATER 20W
55 HEAT DUCT
56 PRODUCT DISPENSER ADAPTER
57 STEAM DEFLECTOR
20015
87024
97135
CD70C
90272
21 POWER CORD
22 TIMER, OPTIONAL - (for automatic units only) 120v
TIMER, IPTIONAL - (for automatic units only) 220v
23 TERMINAL BLOCK SINGLE
24 RELAY (for automatic only) 120v
25 BODY FRAME WELDMENT ASSY
26 Legs, set 2.5" BLK
58 RESTRICTOR
92173
34007
71001
95116
90211
59 RESTRICTOR RETAINER
60 PRODUCT ADJUSTER
61 AUGER SPRING
27 STUD DRIPTRAY
62 AUGER DRIVE COUPLING, PLASTIC
28 DRIP TRAY PAN
29 GRILL
30 DRIP TRAY BRACKET (HOLDER )(OPTIONAL)
31 RINSE SWITCH
32 HEATER SWITCH
75060
75015
RE73A
56039
L299C
63 HOPPER & BASE ASSY
64 AGITATOR DRIVE GEAR
65 AGITATOR
66 PIN/STUD HOPPER
67 GEAR AUGER DRIVE (HOPPER BASE), PLASTIC
97098
90268
40692
04026
90210
33 HEATER INDICATOR LIGHT AMBER
34 WHIPPER MOTOR 115V
35 WHIPPER MOTOR BRACKET PLATED
C002C
52038
92177
68 RETAINER PIN, STEEL (UNDER HOPPER)
69 RETAINER PIN, S/STEEL (on coupling)
70 SIDE PANEL
04025
04030
RC40A
10
ꢁꢁ
ꢀ
ꢀ
DESCRIPTION AND LOCATION Oꢀ COMPONENTS
ICAP1 B LD POUROVER (with lit door)
%ꢀ %ꢁ $'
$& $% $$
$#
%
ꢀ
$"
$!
$
!
"
$ꢀ
$ꢁ
#'
#&
#
$
#%
#$
%
&
##
#"
#!
#
'
#ꢀ
#ꢁ
"'
ꢀꢁ
ꢀꢀ
ꢀ
ꢀ!
"&
"%
"#
ꢀ"
ꢀ#
""
"$
"!
"
"ꢀ
ꢀ$
ꢀ
ꢀ& ꢀ'
ꢀꢀ%% ꢀ ꢀ
& ' !!ꢁꢁ !!ꢀꢀ ! !! !"
! " # $ % & ' ! !! !" !!## !!$$ !!%% !!&& !!''""ꢁꢁ
" # $ %
Illustration No. 9
11
ICAP1 B LD POUROVER (with lit door]
ITEM DESCRIPTION
P/N ITEM DESCRIPTION
P/N
1. COLD TANK COVER ASS'Y
2. COLD WATER TANK WELDMENT ASS'Y
Q164A
Q163Q
37. SLINGER DISC
38. “O” RING
83034
?
3. WATER LEVEL FLOAT/CONTROL SWITCH (COLD)
4. TANK TOP ASS'Y (FOR HOT WATER TANK)
L499A
Q166Q
L467A
97128
20039
39. MIXING CHAMBER MOUNT
40. MIXER BLADE
41. MIXING CHAMBER EXTENDER TUBE
42. MIXING CHAMBER
83033
90230
77184
95001
83036
5.
DISPENSE (DUMP) VALVE (MULLER)
6. TANK BAFFLE ASS'Y
7. TANK CLAMP SEAL
43. MIXING CHAMBER INSERT
8. TANK CLAMP ASS'Y
9. HEATER ELEMENT 1750W 120V
10. WASHER, HEATER ELEMENT
97131
G0140
07059
44. LAMP HOLDER MOUNTING BRACKET ( Lit Door )
46. BREW SWITCH
47. LAMP SOCKET - LEVITTON (for Lit Door only)
RE52C
L455A
44496
11. NUT, HEATER ELEMENT
03051
Q165Q
59024
09246
48. FLUORESCENT LAMP 9W (for Lit Door only)
49. DOOR WELDEMENT ASS'Y - ICAP1 B LD POUROVER RC53Q
L042A
12. HOT WATER TANK WELDMENT ASS'Y
13. HI-LIMIT TEMPERATURE CONTROL
14. ELBOW, MALE 1/8 NPT X 1/4
50. TOP FRONT COVER
51. AUGER MOTOR BRACKET
RC42A
73272
15. CONTROL THERMOSTAT
16. HOSE NUT
17. WATER VALVE INLET ASS'Y
59016
95101
L477A
52. AUGER MOTOR 115V
53. O RING
54. GEAR, AUGER DRIVE MOTOR GEAR, PLASTIC
52037
20015
90208
18. HEATER SWITCH
19. AUTO REFILL SWITCH
20. POWER CORD
21. LEGS, SET 2.5" BLK
23. RELAY (DOUBLE POLE-on at all times) 120V
24. TERMINAL BLOCK SINGLE
25. BODY FRAME WELDMENT ASS'Y
L299A
L299A
44242
M034A
L018A
B135A
RI88Q
55. SUPPORT PLATE F/AUGER MOTOR
56. CARTRIDGE HEATER 20W
57. HEAT DUCT
58. PRODUCT DISPENSER ADAPTER
59. STEAM DEFLECTOR
60. RESTRICTOR
61. RESTRICTOR RETAINER
90209
87024
97135
CD70A
90272
92172
34007
26. POWER SWITCH (TOGGLE)
27. POWER INDICATOR LIGHT, (red)
28. GRILL
L069A
C165A
75015
62. PRODUCT ADJUSTER
63. AUGER SPRING
71001
95116
90211
64. AUGER DRIVE COUPLING, PLASTIC
29. DRIP TRAY PAN
75060
RE73A
92007
65. HOPPER & BASE ASS'Y
66. AGITATOR DRIVE GEAR
67. AGITATOR
97098
90268
40692
30. DRIPTRAY BRACKET (HOLDER)(OPTIONAL)
31. STUD, DRIPTRAY
68. PIN/STUD HOPPER
69. GEAR AUGER DRIVE (HOPPER BASE), PLASTIC
04026
90210
32. HEATER INDICATOR LIGHT AMBER
C002A
33. RINSE SWITCH
34. INDICATOR LIGHT, GREEN "out of water/refill tank"
35. WHIPPER MOTOR 115V
56039
C072A
52038
92177
70. RETAINER PIN, STEEL (under Hopper)
71. RETAINER PIN, S/STEEL (on Coupling)
72. SIDE PANEL
04025
04030
RC40A
36. WHIPPER MOTOR BRACKET PLATED
12
DESCRIPTION AND LOCATION Oꢀ COMPONENTS
ICAP MINI B LD (w/Lit Door) and MINI WHIPPER B (w/o Lit Door)
ꢀ
!
$& $% $$ $#
$"
$!
$
$ꢀ
"
#
$ꢁ
#'
#&
#%
#$
##
$
%
&
'
ꢀꢁ
#"
#!
#
ꢀꢀ
ꢀ
ꢀ!
#ꢀ
#ꢁ
ꢀ"
ꢀ#
"'
"&
"%
"$
ꢀ$
ꢀ%
ꢀ&
ꢀ'
"#
""
"!
"
ꢁ
"ꢀ
"ꢁ
!'
!&
!%
' !ꢁ !ꢀ ! !! !" !# !$
! "
%
&
ꢀ
# $
Illustration No. 10
13
ICAP MINI 1 B LD w/lit door) & MINI WHIPPER B (w/o lit door)
P/N ITEM DESCRIPTION
ITEM DESCRIPTION
P/N
1
2
3
4
5
6
7
TANK TOP ASSY W/QC
SILICONE TUBING (HOSE)
HOSE CLAMP, METAL
CHECK VALVE, PLASTIC
TANK BAFFLE ASSY
TANK BAFFLE SEAL
97166
77216
34034
M323A
97170
20039
97131
35 PLATE - MIX CHAMBER
36 SEAL - MIX CHAMBER (GASKET)
37 WING NUT
38 HOSE BARB S/S 1/4 WITH FITTING
39 MIXING CHAMBER
40 EXTENDER-MIXING CHAMBER
41 LAMP HOLDER MOUNTING BRACKET (for lit Door RE52A
40138
20032
03005
K436A
97169
83041
TANK CLAMP ASSY
8
9
HEATER ELEMENT 1500W/110V
WASHER, HEATER ELEMENT
87037
07059
03051
97165
59010
42 BALLAST (for lit Door only) (CA33C older units
43 PRODUCT SWITCH
44 LAMP SOCKET - LEVITTON (for lit Door only)
45 FLOURESCENT LAMP 9W (for lit Door only)
46 DOOR WELDMENT ASSY - ICAP 1 B LD
CE221
L455A
44496
L042A
RC53Q
10 NUT, HEATER ELEMENT
11 TANK
12 HI-LIMIT TEMPERATURE CONTROL
13 DRAIN PLUG, BRASS
14 CONTROL THERMOSTAT
15 TOP FRONT COVER
16 HOSE BARB FITTING
K044A
59016
RC42A
K435A
47 AUGER MOTOR BRACKET
48 AUGER MOTOR 115V
49 SUPPORT PLATE F/AUGER MOTOR
50 GEAR, AUGER DRIVE MOTOR GEAR, PLASTIC
73272
52037
90209
90208
17 ADJ. VALVE ASSY #H5107 NPT
18 HOSE NUT
19 WATER VALVE INLET ASSY
20 POWER CORD
K415A
95101
L477A
44242
58017
51 O RING
52 CARTRIDGE HEATER
53 HEAT DUCT
54 PRODUCT GUIDE (SHUTE)
55 STEAM DEFLECTOR
20015
87024
97167
CD70A
90272
21 TIMER (for automatic units only) 120v
22 TERMINAL BLOCK SINGLE
23 BODY FRAME WELDMENT ASSY
24 LEGS (2.5") BLACK, PLASTIC (OPTIONAL)
RUBBER FEET 1" BLACK (W/O BRACKETS
25 STUD-DRIP TRAY
B135A
RG94Q
M034A
18003
92007
75060
56 RESTRICTOR
57 RETAINER
58 PRODUCT ADJUSTER
92173
34007
71001
59 AUGER SPRING
60 AUGER DRIVE COUPLING, PLASTIC
95116
90211
26 DRIP TRAY PAN
27 GRILL
75015
61 HOPPER & BASE ASSY
62 GEAR, AGITATOR DRIVE
63 AGITATOR
64 PIN (STUD) HOPPER
65 GEAR AUGER DRIVE (HOPPER VBASE), PLASTIC 90210
97098
90268
40692
04026
28 BRACKET-DRIP TRAY HOLDER (OPTIONAL W/2.5" LEGS ONLY) RE73A
29 RINSE SWITCH
30 HEATER SWITCH
31 HEATER INDICATOR LIGHT AMBER
56039
L299A
C002A
32 NUT - FOR SPACER
33 WASHER - FOR SPACER
34 SPACER - MIX CHAMBER (STUD)
03003
07007
05041
66 RETAINER PIN, STEEL, (UNDER HOPPER)
67 RETAINER PIN, S/STEEL, (ON COUPLING)
68 SIDE PANEL
04025
04030
RC75A
14
AUTOMATIC:ꢀꢀICAP 1 B LD [LIT DOOR]
&
WHIPPER B [NO LIT DOOR]
AUTOMATIC: ICAP 1 MINI B LD [LIT DOOR]
&
MINI WHIPPER B [NO LIT DOOR]
15
MANUAL - ICAP 1 B LD [LIT DOOR]
MANUAL - ICAP 1 MINI B LD [LIT DOOR]
16
DOOR UNIT
INDICATOR LIGHT
"OUT Oꢀ WATER"
"REꢀILL TANK"
NOTE: TO CONVERT TO TIMER CONTROLLED DISPENSE,
CONNECT "BLUE" WIRE TO TIMER TERMINAL "L1".
CONNECT "YELLOW" WIRES TO TIMER TERMINAL "NO".
CONNECT "ORANGE" WIRES TO TIMER TERMINAL "N".
USE PIGGY BACK TERMINAL PROVIDED.
17
18
|