| ® BUNN   TNT-3   TNTF-3   OPERATING & SERVICE MANUAL   BUNN-O-MATIC CORPORATION   POST OFFICE BOX 3227   SPRINGFIELD, ILLINOIS 62708-3227   TELEPHONE: (217) 529-6601 FAX: (217) 529-6644   28201.0000C 8/00 © 1997 Bunn-O-Matic Corporation   USER NOTICES   Carefully read and follow all notices on the equipment and in this manual. They were written for your protection.   All notices on the equipment should be kept in good condition. Replace any unreadable or damaged labels.   #00831.0000   #00656.0000   #03408.0000   #03409.0000   28201 081598   Page 3   ELECTRICAL REQUIREMENTS   CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.   120V model brewers require 2-wire, grounded service rated 120 volt   ac, 15 amp, single phase, 60 Hz.   L2 RED   120/208V model brewers require 3-wire, grounded service rated 120/   208 volt, 20 amp, single phase, 60 Hz.   120V.A.C.   WHITE   208V.A.C.   NEUTRAL   L1 BLACK   120V.A.C.   Electrical Hook-Up   CAUTION – Improper electrical installation will damage electronic components.   1. An electrician must provide electrical service as specified.   2. Remove the top lid and rotate the control thermostat knob fully counterclockwise to the "OFF" position.   3. a) 120V brewers have an attached cordset. Plug in the brewer and proceed to #6.   b) 120/208V brewers, feed the cord through the strain refief at the rear of the brewer and connect it to the   terminal block.   4. Using a voltmeter, check the voltage and color coding of each conductor at the power source.   5. Connect the brewer to the power source and verify the voltage at the terminal block.   6. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing   has been hooked up, the brewer is ready for Initial Set-Up.   PLUMBING REQUIREMENTS   These brewers must be connected to a cold water system with operating pressure between 20 (138) and 90   1 psi (620 kPa) from a ⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer.   Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The   1 water inlet fitting is ⁄4" flare.   1 3 NOTE - Bunn-O-Matic recommends ⁄4" copper tubing for installations of less than 25 feet and ⁄8" for more than   1 25 feet from the ⁄2" water supply line. A tight coil of copper tubing in the water line will facilitate moving the   brewer to clean the countertop. Bunn-O-Matic does not recommend the use of a saddle valve to install the   brewer. The size and shape of the hole made in the supply line by this type of device may restrict water flow.   This equipment must be installed to comply with the Basic Plumbing Code of the   Building Officials and Code Administrators International, Inc. (BOCA)   and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).   28201 081500   Page 4   PLUMBING REQUIREMENTS (cont.)   P1394   P1392   BREWERS W/OUT FAUCET   BREWERS W/FAUCET   1. Remove the shipping cap(s) from the bulkhead fitting(s) on the rear of the brewer.   2. Attach the flare fitting from the short piece of tubing on the strainer/flow control (supplied) to the water inlet   fitting(s) at the rear of the brewer.   3. Flush the water line and securely attach it to the flare fitting on the tee or strainer/flow control.   4. Turn on the water supply.   5. On Brewers with a faucet place an empty vessel beneath the faucet and lift the handle until water is dis-   pensed.   INITIAL SET-UP   CAUTION – The brewer must be unplugged throughout the initial set-up, except when specified in the in-   structions.   1. Remove the top lid from the brewer.   2. Rotate the control thermostat knob fully counterclockwise to the “OFF” position and replace the top lid.   3. Insert the funnel (empty) into the funnel rails.   4. Place an empty tea dispenser on the brewer base. Be prepared to empty the dispenser a few times.   5. Plug in the brewer, place the ICED/OFF/HOT switch in the “HOT” position, and momentarily press the start   switch. When the flow of water into the tank stops, press the start switch to initiate a second cycle. Wait until   the flow of water stops and start a third cycle.. During the third cycle, the tank will fill to its capacity and the   excess will flow from the funnel into the dispenser. Empty the dispenser when this third cycle stops.   6. Place the ICED/OFF/HOT switch in the “ICED” position and begin another brew cycle.   7. Measure the total water volume from the dispenser. It should be approximately (396 ounces.)   8. If not, adjust the Iced Tea timer as required. See Adjusting Brew Volumes.   9. Start and measure another cycle.   10. Repeat steps 7-9 until the recommended total water volume (396 ounces) is achieved.   11. The concentrate valve is preadjusted to deliver the correct ratio of brew water to dilution water.   12. Unplug the brewer, remove the top lid, rotate the control thermostat knob fully clockwise to the “ON” position   and replace the top lid.   28201 081500   Page 5   INITIAL SET-UP (cont.)   13. Empty the dispenser.   14. Plug in the brewer and wait for the water in the tank to heat to brewing temperature (approximately 20   minutes). Some water will drip from the funnel during this time; this is due to expansion and should not   occur thereafter.   15. Place the ICED/OFF/HOT switch in the “HOT” position and begin another brew cycle. Empty the reservoir   after water has stopped flowing from the funnel.   16. Allow the water in the tank to heat to the proper temperature and begin another brew cycle.   17. Measure the total water volume from the dispenser. It should be approximately 64 ounces.   18. If not, adjust the Hot Tea timer as required. See Adjusting Brew Volumes.   19. Start and measure another cycle.   20. Repeat steps 17-19 until the recommended total water volume (64 ounces) is achieved.   21 The brewer is now ready to brew approximately one-half gallon of hot tea or 3-gallons of freshly brewed   room temperature tea.   ADJUSTING BREW VOLUMES   CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement   or adjustment of any component.   NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply, the tank is   properly filled, and a funnel and server are in place.   1. Modifying batch sizes. To modify a batch volume, first check that the SET/LOCK switch is in the “SET”   position on the circuit board.   To increase a batch size. Press and hold the START or BREW switch until three clicks are heard. Release the   switch (Failure to release the switch within two seconds after the third click causes the volume setting to be   aborted and previous volume setting will remain in memory) and press it again one or more times. Each time   the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order   to verify that the desired volume has been achieved.   To decrease a batch size. Press and release the START or BREW switch once for every two-second interval   to be removed from the total brew time period; then immediately press and hold down the START or BREW   switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after   the third click causes the volume setting to be aborted and previous volume setting will remain in memory).   Allow the brew cycle to finish in order to verify that the desired volume has been achieved.   2. Setting batch sizes. To set a batch volume, first check that the SET/LOCK switch is in the “SET” position on   the circuit board. Press and hold the START or BREW switch until three distinct clicks are heard, and then   release the switch. (Failure to release the switch within two seconds after the third click causes the volume   setting to be aborted and previous volume setting will remain in memory). View the level of the liquid being   dispensed. When the desired level is reached, turn the ON/OFF switch to “OFF” (lower). The brewer remem-   bers this volume and will continue to brew batches of this size until the volume setting procedure is repeated.   NOTE: When brewing coffee, batch volumes will decrease due to absorption by the coffee grounds.   3. Setting programming disable feature. If it becomes necessary to prevent anyone from changing brew times   once programmed, you can set the SET/LOCK switch to the “LOCK” position. This will prevent any program-   ming to be done until switch is once again placed in the “SET” position.   28201 081500   Page 6   CLEANING   CAUTION – Do not keep brewed tea overnight. Clean and sanitize your iced tea dispenser daily   1. Remove and thoroughly clean the brew funnel. The funnel tip and screen must be free from any tea particles   or residue. Reassemble the funnel.   2. Unplug the brewer. Remove and thoroughly rinse the sprayhead. The holes must be open and clear of any   mineral deposits. Wipe the sprayhead panel clean with a damp cloth.   3. Insert the deliming spring into the sprayhead fitting until no more than one inch is visible and move it in and   out 5 or 6 times. Insert the spring into the airvent hole in the sprayhead panel and move it in and out 5 or 6   times. Reattach the sprayhead.   4. Wash the entire outside surface of the brewer with a clean damp cloth.   OPERATING CONTROLS   A. ICED/OFF/HOT Switch   ICED – Placing the switch in the left position allows the start switch to activate a timed brew cycle delivering   .5 gallon of tea concentrate and 2.5 gallons of dilution water into the dispenser.   OFF – Placing the switch in the center position stops the brew cycle. Stopping a brew cycle after it has   started will not stop the flow of water into the funnel until the tank syphons down to its level. The switch should   always be placed in this position after a brew cycle and whenever the brewer is unattended.   HOT – Placing the switch in the right position allows the start switch to activate a timed brew cycle delivering   .5 gallon of hot tea into an airpot dispenser.   B. Start Switch   Starts a brew cycle when the ICED/OFF/HOT switch is in either the “ICED” or “HOT” position.   BREWING   1. Begin brewing with a clean empty brew funnel and dispenser. (Be sure the dispenser is open.)   2. Insert a BUNN® filter into the funnel.   3. Pour the fresh loose tea leaves into the filter.   4. Level the bed of tea leaves by gently shaking.   5. Slide the funnel into the funnel rails until it stops.   6. Place the ICED/OFF/HOT switch in the desired position.   7. Momentarily press the start switch.   8. Carefully remove the brew funnel and discard its contents after liquid stops flowing from the funnel.   CAUTION – The funnel contains hot liquid. Remove funnel slowly.   9. Place the ICED/OFF/HOT switch in the “OFF” position to prevent a false start.   28201 081500   Page 7   TROUBLESHOOTING   A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems   encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic   Technical Service Department.   • • • Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-   nel.   All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of   terminals or the application of external voltages may result in board failure.   Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an   intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a   terminal or crimp.   • • Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are   energized for more than ten minutes without a supply of water.   The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will   help to avoid twists and kinks in the tubing.   • • Make certain that all plumbing connections are sealed and electrical connections tight and isolated.   This brewer is heated at all times. Keep away from combustibles.   WARNING –   • Exercise extreme caution when servicing electrical equipment.   • Unplug the brewer when servicing, except when electrical tests are specified.   • Follow recommended service procedures   • Replace all protective shields or safety notices   Remedy   Problem   Probable Cause   Water lines and valves to the brewer   must be open.   Brew cycle(s) will not start   1. No water   Check circuit breakers or fuses.   2. No power or incorrect voltage to   the brewer   (A) Direction of flow arrow must be   pointing towards the brewer.   3.External Strainer/ Flow Control   (.750 GPM)   (B) Remove the strainer/flow con-   trol and check for obstructions.   Clear or replace.   Refer to Service - ICED/OFF/HOT   Switch for testing. See page 26   4. ICED/OFF/HOT Switch   5. Start Switch   Refer to Service - Start Switch for   testing procedures. See page 27   28201 081500   Page 8   TROUBLESHOOTING (cont.)   PROBLEM   PROBABLE CAUSE   REMEDY   6. Brew Timer   A) Iced Tea   Brew cycle(s) will not start (cont.)   Refer to Service - Brew Timer (Iced   Tea) for testing procedures. See   page 20 or 21   B) Hot Tea   Refer to Service - Brew Timer (Hot   Tea) for testing procedures. See   page 17 or 18   7. Brew Solenoid Valve   A) Iced Tea   Refer to Service - Brew Solenoid   Valve (Iced Tea) for testing proce-   dures. See page 16   B) Hot Tea   Refer to Service- Brew Solenoid   Valve (Hot Tea) for testing proce-   dures. See page 15   8. Internal Flow control (.222 GPM)   (Hot Tea Only)   (A) Direction of flow arrow must be   pointing towards brewer.   (B) Remove the flow control and   check for obstructions. Clear or re-   place.   1. Limit Thermostat   CAUTION - Do not eliminate or by-   pass limit thermostat. Use only   Brew water is not hot   Refer to Service - Limit Thermostat   for testing procedures. See page 25   BOM   replacement   part   #29329.1000   2. Thermal Fuse   CAUTION - Do not eleminate or by-   pass thermal fuse.   Refer to Service - Thermal fuse for   testing procedures. See page 29   3. Control Thermostat   Refer to Service - Control Thermo-   stat for testing procedures. See   page 23   4. Tank Heater   Refer to Service - Tank Heater for   testing procedures. See page 28   1. ICED/OFF/HOT Switch   Dilution (Iced Tea) cycle will not   start   Refer to Service - ICED/OFF/HOT   Switch for testing procedures. See   page 26   28201 081500   Page 9   TROUBLESHOOTING (cont.)   PROBLEM   PROBABLE CAUSE   REMEDY   Dilution (Iced Tea) cycle will not 2. Start Switch   start (cont.)   Refer to Service - Start Switch for   testing procedures. See page 27   3. Brew Timer (Iced Tea)   Refer to Service- Brew Timer (Iced   Tea) for testing procedures. See   page 20 or 21   4. Brew Solenoid Valve (Iced Tea)   5. Dilution Solenoid Valve   Refer to Service - Brew Solenoid   Valve (Iced Tea) for testing proce-   dures. See page 16   Refer to Service - Dilution Solenoid   Valve for testing procedures. See   page 24   Inconsistent beverage level in   dispenser (Hot Tea)   1. Internal Flow Control (.222 GPM) (A) Direction of flow arrow must be   pointing towards the brewer.   (B) Remove the flow control and   check for obstruction. Clear or re-   place.   2. Syphon System   3. Lime Build-up   The brewer must be level or slightly   lower in front to syphon properly.   Inspect the tank assembly for ex-   CAUTION - Tank and tank compo- cessive lime deposits. Delime as   nents should be delimed regularly required.   depending on local water condi-   tions. Excessive mineral build-up   on stainless steel surfaces can ini-   tiate corrosive reactions resulting   in serious leaks.   4. Water Pressure   The water pressure to the brewer   must be at least 20 psi.   Consistently high or low beverage   level in the dispenser   1. Brew Timer   With the ICED/OFF/HOT switch in   the "ICED" position adjust the needle   valve to achieve the recommended   76 oz of concentrate then the timer   to achieve a total of 396 oz for each   three-gallon brew cycle.   28201 081500   Page 10   TROUBLESHOOTING (cont.)   PROBLEM   REMEDY   PROBABLE CAUSE   Consistently high or low beverage   level in the dispenser. (cont.)   (A) Direction of flow arrow must be   pointing towards brewer.   2. External Strainer/Flow Control   (.750 GPM)   (B) Remove the strainer/flow con-   trol and check for obstructions.   Clear or replace.   Spitting or excessive steaming   Inspect tank assembly for excessive   lime deposits. Delime as required.   1. Lime Build-up   CAUTION - Tank and tank compo-   nents should be delimed regularly   depending on local water condi-   tions. Excessive mineral build-up   on stainless steel surfaces can ini-   tiate corrosive reactions resulting   in serious leaks.   Refer to Service - Control Thermo-   stat for testing procedures. See   page 23   2. Control Thermostat   Drip-out time too long   The brew funnel should be cleaned   thoroughly before each brew cycle   to lessen the chance of tea leaf par-   ticles clogging the drip-out tip.   1. Funnel Tip   Dripping from sprayhead   The brewer must be level or slightly   lower in front to syphon properly.   1. Syphon System   Inspect the tank assembly for ex-   cessive lime deposits. Delime as   required.   2. Lime Build-up   CAUTION - Tank and tank compo-   nents should be delimed regularly   depending on local water condi-   tions. Excessive mineral build-up   on stainless steel surfaces can ini-   tiate corrosive reactions resulting   in serious leaks.   Refer to Service - Brew Solenoid   Valve (Iced Tea) for testing proce-   dures. See page 16   3. Brew Solenoid Valve   A) Iced Tea   Refer to Service- Brew Solenoid   Valve (Hot Tea) for testing proce-   dures. See Page 15   B) Hot Tea   28201 081500   Page 11   TROUBLESHOOTING (cont.)   PROBLEM   REMEDY   PROBABLE CAUSE   Water flows into tank continuously 1. Brew Timer   Refer to Service - Brew Timer (Iced   Tea) for testing procedures. See   page 20   (ICED/OFF/HOT Switch in the "ICED   or "HOT" position)   A) Iced Tea   Refer to Service- Brew Timer (Hot   Tea) for testing procedures. See   page 17   B) Hot Tea   Water flows into tank continuously 1. Brew Solenoid Valve   Refer to Service - Brew Solenoid   Valve (Iced Tea) for testing proce-   dures. See page 16   (ICED/OFF/HOT Switch in the "OFF"   position)   A) Iced Tea   Refer to Service- Brew Solenoid   Valve (Hot Tea) for testing proce-   dures. See page 15   B) Hot Tea   The dispenser must be completely   empty before starting a brew cycle.   Beverage overflows dispenser   1.Dispenser   2. Brew Timer   A) Iced Tea   Refer to Service - Brew Timer (Iced   Tea) for testing procedures. See   page 20 or 21   Refer to Service- Brew Timer (Hot   Tea) for testing procedures. See   page 17 or 18   B) Hot Tea   3. Brew Solenoid Valve   A) Iced Tea   Remove the Iced Tea Brew Solenoid   Valve and clean any obstruction.   Rebuild or replace the valve if nec-   essary. See page 16   Remove the Hot Tea Brew Solenoid   Valve and clean any obstruction.   Rebuild or replace the valve if nec-   essary. See page 15   B) Hot Tea   4. Dilution Solenoid Valve   Page 12   Refer to Service - Dilution Solenoid   Valve for testing procedures. See   page 24   28201 081500   TROUBLESHOOTING (cont.)   REMEDY   PROBLEM   Weak beverage   PROBABLE CAUSE   1. Filter Type   BUNN® paper filters must be used   for proper extraction.   A sufficient quantity of fresh, loose   tea leaves should be used for proper   extraction.   2. Tea   A six-hole stainless steel spray-   head must be used for proper ex-   traction.   3. Sprayhead   The BUNN® paper filter must be cen-   tered in the funnel and the bed of tea   leaves leveled by gentle shaking.   4. Funnel Loading   5. Water Temperature   Place an empty funnel on an empty   dispenser beneath the sprayhead. Ini-   tiate a brew cycle and check the wa-   ter temperature immediately below   the sprayhead with a thermometer.   The reading should not be less than   200°F (93°C). Adjust the control ther-   mostat to increase the water tempera-   ture. Replace if necessary.   The BUNN® paper filter must be cen-   tered in the funnel and the bed of   grounds leveled by gently shaking.   Dry tea leaves remain in the   funnel   1. Funnel Loading   1. Solenoid(s)   The nut on the solenoid(s) must be   tight or it will vibrate during opera-   tion.   Brewer is making unusal noises   Plumbing lines should not be rest-   ing on the counter top.   2. Plumbing Lines   3. Water Supply   (A) The brewer must be connected   to a cold water line.   (B) Water pressure to the brewer   must not exceed 90 psi (620 kPa).   Install a regulator if necessary to   lower the working pressure to ap-   proximately 50 psi (345 kPa).   Remove and clean lime off the tank   4. Tank Heater   Page 13   heater. See page 28   28201 081500   SERVICE   This section provides procedures for testing and   replacing various major components used in this   brewer should service become necessary. Refer to   Troubleshooting for assistance in determining the   cause of any problem.   WARNING - Inspection, testing, and repair of electri-   cal equipment should be performed only by qualified   service personnel. The brewer should be disconnected   from the power source when servicing, except when   electrical tests are required and the test procedure spe-   cifically states to plug in the brewer.   COMPONENT ACCESS   WARNING - Disconnect the brewer from the power   source before the removal of any panel or the replace-   ment of any component.   All components are accessible by the removal of   the top cover and rear inspection panel.   The top cover is attached with four #6-32 screws.   Removal of the top cover will allow access to ICED/   OFF/HOT switch, start switch, brew timers, control   thermostat, limit thermostat, thermal fuse and tank   heater.   P1370.40   The rear inspection panel is attached with six #8-   32 screws. Removal of the rear panel will allow access   to the brew solenoid valves and the dilution solenoid   valve .222 GPM flow control and check valve.   FIG. 1 COMPONENT ACCESS   Contents   Brew Solenoid Valve (Hot Tea)............................ 15   Brew Solenoid Valve (Iced Tea) .......................... 16   Brew Timer (Hot Tea) (Early Models).................. 17   Digital Brew Timer (Hot Tea )(Late Models)........ 18   Brew Timer (Iced Tea) (Early Models)................. 20   Digital Brew Timer (Iced Tea)(Late Models ......... 21   Control Thermostat............................................. 23   Dilution Solenoid Valve ....................................... 24   Limit Thermostat ................................................ 25   ICED/OFF/HOT Switch......................................... 26   Start Switch ........................................................ 27   Tank Heater......................................................... 28   Thermal Fuse ...................................................... 29   Wiring Diagrams................................................. 30   28201 081500   Page 14   SERVICE (cont.)   If continuity is not present as described, replace the   solenoid valve.   BREW SOLENOID VALVE (HOT TEA)   6. Check the hot tea solenoid valve for coil action.   Connect the brewer to the power source. With   ICED/OFF/HOT switch in the "HOT" position press   the start switch and listen carefully in the vicinity   of the solenoid valve for a "clicking" sound as the   coil magnet attracts.   7. Disconnect the brewer from the power source.   If the sound is heard as described and water will not   pass through the solenoid valve, there may be a block-   age in the water line before the solenoid valve or, the   solenoid valve may require inspection for wear, and   removal of waterborne particles.   If the sound is not heard as described, replace the   solenoid valve.   P1391.60   Removal and Replacement:   FIG. 2 HOT TEA BREW SOLENOID VALVE   Location:   Viewing the brewer from the rear, the hot tea brew   solenoid valve is mounted on the left side of the   mounting bracket.   1. Remove all wires from solenoid valves.   2. Turn off the water supply to the brewer.   3. Disconnect the water lines to and from the sole-   noid valves.   4. Remove the two #8-32 keps nuts holding the   mounting bracket to the brewer base.   5. Lift out the bracket.   6. Remove the two #10-32 slotted-head screws hold-   ing the hot tea solenoid valve to the mounting   bracket.   7. Securely install the new hot tea solenoid valve to   the mounting bracket.   Test Procedures:   1. Disconnect the brewer from the power source.   2. Disconnect the white/red and white/green wires   from the hot tea solenoid valve. With the ICED/   OFF/HOT switch in the "HOT" position press the   start switch.   3. With a voltmeter, check the voltage across the   white/red and white/green wires. Connect the   brewer to the power source. The indication must   be 120 volts ac for two wire 120 volt models and   three wire 120/208 volt models.   8. Attach the mounting bracket to the brewer base.   9. Securely fasten the water lines to and from the   solenoid valves.   10. Refer to Fig.3 when reconnecting the wires.   WHI/GRN to Hot Tea   Timer TL 4   WHI/RED to Hot Tea Timer TL 1   4. Disconnect the brewer from the power source.   WHI/VIO to Dilution Solenoid   WHI/VIO to Iced Tea Brew Timer TL 1   WHI/BLU to Iced Tea Timer TL 4   If voltage is present as described, proceed to #5   If voltage is not present as described, refer to Wiring   Diagram and check brewer wiring harness.   WHI/VIO to Iced Tea   Brew Timer TL 1   HOT TEA BREW   SOLENOID   5. Check for continuity across the hot tea solenoid   valve coil terminals.   ICED TEA BREW   SOLENOID   WHI/BLU to Iced   Tea Timer TL 4   If continuity is present as described, reconnect the   white/red and white/green wires from the hot tea brew   timer.   DILUTION   SOLENOID   P1364   FIG.3 SOLENOID VALVE TERMINALS   28201 081598   Page 15   SERVICE (cont.)   If continuity is not present as described, replace the   solenoid valve.   BREW SOLENOID VALVE (ICED TEA)   6. Check the iced tea solenoid valve for coil action.   Connect the brewer to the power source. With   ICED/OFF/HOT switch in the "ICED" position press   the start switch and listen carefully in the vicinity   of the solenoid valve for a "clicking" sound as the   coil magnet attracts.   7. Disconnect the brewer from the power source.   If the sound is heard as described and water will not   pass through the solenoid valve, there may be a block-   age in the water line before the solenoid valve, or the   solenoid valve may require inspection for wear, and   removal of waterborne particles.   If the sound is not heard as described, replace the   solenoid valve.   Removal and Replacement:   P1391.60   FIG. 4 ICED TEA BREW SOLENOID VALVE   Location:   1. Remove all wires from solenoid valves.   2. Turn off the water supply to the brewer.   3. Disconnect the water lines to and from the sole-   noid valves.   4. Remove the two #8-32 keps nuts holding the   mounting bracket to the brewer base.   5. Lift out the bracket.   6. Remove the two #10-32 slotted-head screws hold-   ing the iced tea brew solenoid valve to the mount-   ing bracket.   7. Securely install the new iced tea brew solenoid   valve to the mounting bracket.   Viewingthebrewerfromtherear,theicedteabrew   solenoid valve is mounted in the center of the mount-   ing bracket.   Test Procedures:   1. Disconnect the brewer from the power source.   2. Disconnect the white/violet and white/blue wires   from the iced tea brew solenoid valve. With the   ICED/OFF/HOT switch in the "ICED" position press   the start switch.   3. With a voltmeter, check the voltage across the   white/violet and white/blue wires. Connect the   brewer to the power source. The indication must   be 120 volts ac for two wire 120 volt models and   three wire 120/208 volt models.   8. Attach the mounting bracket to the brewer base.   9. Securely fasten the water lines to and from the   solenoid valves.   10. Refer to Fig. 5 when reconnecting the wires.   WHI/GRN to Hot Tea   Timer TL 4   WHI/RED to Hot Tea Timer TL 1   4. Disconnect the brewer from the power source.   WHI/VIO to Dilution Solenoid   WHI/VIO to Iced Tea Brew Timer TL 1   WHI/BLU to Iced Tea Timer TL 4   If voltage is present as described, proceed to #5   If voltage is not present as described, refer to Wiring   Diagram and check brewer wiring harness.   WHI/VIO to Iced Tea   Brew Timer TL 1   HOT TEA BREW   SOLENOID   5. Check for continuity across the iced tea brew so-   lenoid valve coil terminals.   ICED TEA BREW   SOLENOID   WHI/BLU to Iced   Tea Timer TL 4   If continuity is present as described, reconnect the   white/violet and white/blue wires from the iced tea   brew timer.   DILUTION   SOLENOID   P1364   FIG.5 SOLENOID VALVE TERMINALS   28201 081598   Page 16   SERVICE (cont.)   If continuity is not present as described, refer to the   Wiring Diagram and check the wiring harness.   BREW TIMER (HOT TEA - EARLY MODELS)   5. Check the voltage across terminals TL1 and TL4   with a voltmeter when the ICED/OFF/HOT switch   is in the “HOT” position and the start switch is   momentarily placed in the lower position. Con-   nect the brewer to the power source. The indica-   tion must be 120 volts ac for two wire 120 volt   models and three wire 120/208 volt models for   approximately twenty seconds and then return to   its previous indication.   6. Disconnect the brewer from the power source.   If voltage is present as described, the timer is operat-   ing properly. Adjust the timer dial as required.   If voltage is not present as described, replace the timer.   Removal and Replacement:   OLD STYLE   1. Remove all wires from the timer.   2. Remove the circuit board and dial plate from the   brackets.   3. Install the new timer circuit board as described in   Late Model Timer section on the following pages.   4. Refer to Fig.9 when reconnecting the wires.   5. Install the Timer Setting Decal, provided with the   timer replacement kit, on the bottom of the hood   cover.   P1391.60   FIG. 6 HOT TEA BREW TIMER   Location:   Thehotteabrewtimerislocatedinthehoodonthe   left side. It consists of a dial plate and circuit board.   Test Procedure:   1. Disconnect the brewer from the power source.   2. Remove the wires from terminals TL3, TL4, & TL5   of the timer and rotate the dial fully counterclock-   wise.   2. With a voltmeter, check the voltage across termi-   nals TL1 and TL2 when the ICED/OFF/HOT switch   is in the “HOT” position. Connect the brewer to   the power source. The indication must be 120   volts ac for two wire 120 volt models and three   wire 120/208 volt models.   6. Adjust the timer as required. See Late Model Timer   Section on the following pages.   WHI to Power Cord (120V Models)   or WHI to Terminal Block 120/208V   Models)   WHI/RED to Hot Tea Brew Solenoid   WHI/RED to ICED/OFF/HOT Switch   3. Disconnect the brewer from the power source.   WHI/ORN to Start Switch   WHI/GRN to Hot Tea Brew   Solenoid   If voltage is present as described, proceed to #4.   If voltage is not present as described, refer to the Wir-   ing Diagram and check the wiring harness.   WHI/YEL to Start Switch   4. Check for continuity across the white/orange and   white/yellow wires when the start switch is held   in the lower position.   OLD STYLE   P1365.85   FIG. 7 HOT TEA BREW TIMER TERMINALS   If continuity is present as described, reconnect the   wires to terminals TL3, TL4, & TL5 of the timer board   and proceed to #5.   28201 081500   Page 17   SERVICE (cont.)   BREW TIMER (HOT TEA - LATE MODELS)   6. With a voltmeter, check the voltage across termi-   nals TL1 and TL4 when the "ON/OFF" switch is in   the "ON" position and the ICED/OFF/HOT switch is   in the "HOT" position. Connect the brewer to the   power source. The indication must be 0 volts.   If voltage is as described, proceed to #7.   If voltage is not as described, disconnect the brewer   from the power source and replace the timer.   7. With a voltmeter, check the voltage across termi-   nals TL1 and TL4 when the "ON/OFF" switch is in   the "ON" position and the ICED/OFF/HOT switch is   in the "HOT" position. Connect the brewer to the   power source and press the "START" switch. The   indication must be 120 volts ac for two wire 120   volt models and three wire 120/208 volt models.   NEW STYLE   If voltage is present as described, the brew timer is   operating properly. Reset the timer as required, to   obtain the desired brew volume.   If voltage is not present as described, disconnect the   brewer from the power source and replace the timer.   P2213.60   FIG. 8 DIGITAL HOT TEA BREW TIMER   Location:   The hot tea brew timer is located in the hood, on   the left side.   Removal and Replacement:   1. Remove the two #8-32 screws securing circuit   board to the mounting bracket.   2. Remove circuit board and spacers (as required).   3. Remove all wires from the timer.   4. Attach all wires to the replacement timer board   prior to installation to the component mounting   bracket. Refer to FIG. 9 when reconnecting the   wires.   Test Procedure.   NOTE:Donotremoveorinstallwireswhiletimerboard   is installed. Pressure applied to one side may cause   damage to the board.   1. Disconnect the brewer from the power source and   remove hood cover.   2. Remove the two #8-32 screws securing circuit   board to the mounting bracket.   3. Remove circuit board and spacers (as required).   4. With a voltmeter, check the voltage across termi-   nals TL1 and TL2 when the "ON/OFF" switch is in   the "ON" position and the ICED/OFF/HOT switch is   in the "HOT" position. Connect the brewer to the   power source. The indication must be 120 volts ac   for two wire 120 volt models and three wire 120/   208 volt models.   5. Install new circuit board with spacers (as re-   quired) to the component mounting bracket.   6. Adjust the timer as described below.   Timer Setting:   NOTE: Prior to setting or modifying volumes, check   that the brewer is connected to water supply, the tank   is properly filled, and a funnel and server are in place.   NOTE: All volume settings must be done with the   sprayhead installed.   5. Disconnect the brewer from the power source.   If voltage is present as described, proceed to #6.   If voltage is not present as described, refer to the   Wiring Diagram and check the brewer wiring harness.   28201 081500   Page 18   SERVICE (cont.)   procedure is repeated.   BREW TIMER (HOT TEA - LATE MODELS)(cont.)   NOTE: When brewing coffee, volume will decrease due   to absorption by the coffee grounds.   1. Modifying brew volumes. To modify a brew vol-   ume, first check that the SET/LOCK switch is in the   “SET” position on the circuit board.   3. Setting programming disable feature. If it be-   comes necessary to prevent anyone from changing   brew time once programmed, you can set the SET/   LOCK switch to the “LOCK” position. This will pre-   vent any further programming until switch is once   again put into the “SET” position.   To increase a brew volume, place the ON/OFF   switch in the “ON” position, press and hold the START   switch until three clicks are heard. Release the switch   and press it again one or more times. (Failure to re-   lease the switch within two seconds after the third   click causes the volume setting to be aborted and pre-   vious volume setting will remain in memory.) Each   time the switch is pressed, two seconds are added to   the brew time period. Allow the brew cycle to finish in   order to verify that the desired volume has been   achieved.   To decrease a brew volume, place the ON/OFF   switch in the “ON” position, press and release the   START switch once for every two-second interval to   be removed from the total brew time period; then im-   mediately press and hold down the START switch until   three clicks are heard. Release the switch. (Failure to   release the switch within two seconds after the third   click causes the volume setting to be aborted and pre-   vious volume setting will remain in memory). Allow   the brew cycle to finish in order to verify that the de-   sired volume has been achieved.   2. Setting brew volumes. To set a brew volume,   first check that the SET/LOCK switch is in the “SET”   position on the circuit board. Place the ON/OFF switch   in the “ON” position, press and hold the START switch   until three distinct clicks are heard and then release   the switch. (Failure to release the switch within two   seconds after the third click causes the volume set-   ting to be aborted and previous volume setting will   remain in memory.)   TL1 - WHI/RED to Hot Tea Brew Solenoid and   WHI/RED to ICED/OFF/HOT Switch   TL2 - WHI to Power Cord (120V Models) or   WHI to Terminal Block (120/208V Models)   TL3 - WHI/ORN to Start Switch   TL4 - WHI/GRN to Hot Tea Brew Solenoid   TL5 - WHI/YEL to Start Switch   P2037   View the level of the liquid being dispensed. When   the desired level is reached, turn the ON/OFF switch   to “OFF”.   FIG. 9 DIGITAL TIMER WIRING   NOTE: Several ounces of water will continue to sy-   phon from the tank after turning the switch “OFF”.   The brewer remembers this volume and will continue   to brew batches of this size until the volume setting   28201 081500   Page 19   SERVICE (cont.)   If continuity is present as described, reconnect the   wires to terminals TL3, TL4, & TL5 of the timer board   and proceed to #5.   BREW TIMER (ICED TEA - EARLY MODELS)   If continuity is not present as described, refer to the   Wiring Diagram and check the wiring harness.   5. With a voltmeter, check the voltage across termi-   nals TL1 and TL4 when the ICED/OFF/HOT switch   is in the “ICED” position and the start switch is   momentarily placed in the lower position. Con-   nect the brewer to the power source. The indica-   tion must be 120 volts ac for two wire 120 volt   models and three wire 120/208 volt models for   approximately twenty seconds and then return to   its previous indication.   6. Disconnect the brewer from the power source.   If voltage is present as described, the timer is operat-   ing properly. Adjust the timer dial as required.   If voltage is not present as described, replace the timer.   OLD STYLE   P1391.60   FIG. 10 ICED TEA BREW TIMER   Location:   Removal and Replacement:   1. Remove all wires from the iced tea brew timer.   2. Remove the circuit board and dial plate from the   brackets.   3. Install the new timer circuit board as described in   Late Model Timer section on the following pages.   4. Refer to Fig. 13 when reconnecting the wires.   5. Install the Timer Setting Decal, provided with the   timer replacement kit, on the bottom of the hood   cover.   The iced tea brew timer is located in the hood on   the right side. It consists of the dial plate and circuit   board.   Test Procedure:   1. Disconnect the brewer from the power source.   2. Remove the wires from terminals TL3, TL4, & TL5   of the iced tea timer and rotate the dial fully coun-   terclockwise.   2. With a voltmeter, check the voltage across termi-   nals TL1 and TL2 when the ICED/OFF/HOT switch   is in the “ICED” position. Connect the brewer to   the power source. The indication must be 120   volts ac for two wire 120 volt models and three   wire 120/208 volt models.   6. Adjust the timer as required. See Late Model Timer   Section on the following pages.   WHI to Power Cord (120V Models)   or WHI to Terminal Block 120/208V   Models)   WHI/RED to Hot Tea Brew Solenoid   WHI/RED to ICED/OFF/HOT Switch   3. Disconnect the brewer from the power source.   If voltage is present as described, proceed to #4.   If voltage is not present as described, refer to the Wir-   ing Diagram and check the wiring harness.   ORN to Start Switch   WHI/BLU to Iced Tea   Brew Solenoid   YEL to Start Switch   4. Check for continuity across the orange and yel-   low wires when the start switch is held in the lower   position.   OLD STYLE   P1365.85   FIG. 11 ICED TEA BREW TIMER TERMINALS   28201 081500   Page 20   SERVICE (cont.)   BREW TIMER (ICED TEA - LATE MODELS)   6. With a voltmeter, check the voltage across termi-   nals TL1 and TL4 when the "ON/OFF" switch is in   the "ON" position and the ICED/OFF/HOT switch is   in the "ICED" position. Connect the brewer to the   power source. The indication must be 0 volts.   If voltage is as described, proceed to #7.   If voltage is not as described, disconnect the brewer   from the power source and replace the timer.   7. With a voltmeter, check the voltage across termi-   nals TL1 and TL4 when the "ON/OFF" switch is in   the "ON" position and the ICED/OFF/HOT switch is   in the "ICED" position. Connect the brewer to the   power source and press the "START" switch. The   indication must be as follows 120 volts ac for two   wire 120 volt models and three wire 120/208 volt   models.   NEW STYLE   P2213.60   FIG. 12 ICED TEA BREW TIMER   Location:   If voltage is present as described, the brew timer is   operating properly. Reset the timer as required, to   obtain the desired brew volume.   The timer is located in the hood on the right side.   If voltage is not present as described, disconnect the   brewer from the power source and replace the timer.   Test Procedure.   NOTE: Do not remove or install wires while timer   board is installed. Pressure applied to one side may   cause damage to the board.   1. Disconnectthebrewerfromthepowersourceand   remove the front access panel.   2. Remove the two #8-32 screws securing circuit   board to the mounting bracket.   3. Remove circuit board and spacers (as required).   4. With a voltmeter, check the voltage across termi-   nals TL1 and TL2 when the "ON/OFF" switch is in   the "ON" position and the ICED/OFF/HOT switch is   in the "ICED" position. Connect the brewer to the   powersource. Theindicationmustbe120voltsac   for two wire 120 volt models and three wire 120/   208 volt models.   Removal and Replacement:   1. Remove the two #8-32 screws securing circuit   board to the mounting bracket.   2. Remove circuit board and spacers (as required).   3. Remove all wires from the timer.   4. Attach all wires to the replacement timer board   prior to installation to the component mounting   bracket. Refer to FIG. 13 when reconnecting the   wires.   5. Install new circuit board with spacers (as re-   quired) to the component mounting bracket.   6. Adjust the timer as described below.   Timer Setting:   5. Disconnect the brewer from the power source.   NOTE: Prior to setting or modifying volumes, check   that the brewer is connected to water supply, the tank   is properly filled, and a funnel and server are in place.   NOTE: All volume settings must be done with the   sprayhead installed.   If voltage is present as described, proceed to #6.   If voltage is not present as described, refer to the   Wiring Diagrams and check the brewer wiring har-   ness.   28201 081500   Page 21   SERVICE (cont.)   BREW TIMER (ICED TEA - LATE MODELS)(cont.)   1. Modifying brew volumes. To modify a brew vol-   ume, first check that the SET/LOCK switch is in the   “SET” position on the circuit board.   NOTE: When brewing coffee, volume will decrease due   to absorption by the coffee grounds.   3. Setting programming disable feature. If it be-   comes necessary to prevent anyone from changing   brew time once programmed, you can set the SET/   LOCK switch to the “LOCK” position. This will pre-   vent any further programming until switch is once   again put into the “SET” position.   To increase a brew volume, place the ON/OFF   switch in the “ON” position, press and hold the START   switch until three clicks are heard. Release the switch   and press it again one or more times. (Failure to re-   lease the switch within two seconds after the third   click causes the volume setting to be aborted and pre-   vious volume setting will remain in memory.) Each   time the switch is pressed, two seconds are added to   the brew time period. Allow the brew cycle to finish in   order to verify that the desired volume has been   achieved.   To decrease a brew volume, place the ON/OFF   switch in the “ON” position, press and release the   START switch once for every two-second interval to   be removed from the total brew time period; then im-   mediately press and hold down the START switch until   three clicks are heard. Release the switch. (Failure to   release the switch within two seconds after the third   click causes the volume setting to be aborted and pre-   vious volume setting will remain in memory). Allow   the brew cycle to finish in order to verify that the de-   sired volume has been achieved.   2. Setting brew volumes. To set a brew volume,   first check that the SET/LOCK switch is in the “SET”   position on the circuit board. Place the ON/OFF switch   in the “ON” position, press and hold the START switch   until three distinct clicks are heard and then release   the switch. (Failure to release the switch within two   seconds after the third click causes the volume set-   ting to be aborted and previous volume setting will   remain in memory.)   TL1 - WHI/VIO to Iced Tea Brew Solennoid and   WHI/VIO to ICED/OFF/HOT Switch   TL2 - WHI to Power Cord (120V Models) or   WHI to Terminal Block (120/208V Models)   TL3 - ORN to Start Switch   TL4 - WHI/BLU to Iced Tea Brew Solenoid   TL5 - YEL to Start Switch   View the level of the liquid being dispensed. When   the desired level is reached, turn the ON/OFF switch   to “OFF”.   NOTE: Several ounces of water will continue to sy-   phon from the tank after turning the switch “OFF”.   The brewer remembers this volume and will continue   to brew batches of this size until the volume setting   procedure is repeated.   P2037   FIG. 13 DIGITAL TIMER WIRING   28201 081500   Page 22   SERVICE (cont.)   b) 208 volts ac for three wire 120/208 volt mod-   els   8. Disconnect the brewer from the power source.   CONTROL THERMOSTAT   If voltage is present as described, reinstall the capil-   lary tube into the tank to the line 4.5" above the bulb,   the control thermostat is operating properly.   If voltage is not present as described, replace the ther-   mostat.   Removal and Replacement:   1. Remove both wires from the control thermostat   terminals.   2. Remove the thermostat capillary bulb by firmly   pulling up on the capillary tube at the tank lid. This   will disengage the grommet from the tank lid.   3. Remove the #8-32 screw holding the control ther-   mostat to its bracket.   4. Slide the grommet to the line 4.5" above the bulb   on the new capillary tube.   P2213.60   FIG. 14 CONTROL THERMOSTAT   Location:   The control thermostat is located inside hood on   the right side just behind the iced tea brew timer.   5. Insert the capillary bulb through the hole in the   tank lid and press the grommet firmly and evenly   so that the groove in the grommet fits into the   tank lid.   6. Carefully bend the capillary tube so that the tube   and bulb inside the tank are in a vertical position.   Test Procedures:   1. Disconnect the brewer from the power source.   2. With a voltmeter, check the voltage across the blue   wire on the control thermostat and the white wire   on the tank heater for 120 volt two wire models or   red wire on the tank heater for 120/208 volt three   wire models. Connect the brewer to the power   source. The indication must be:   NOTE – The capillary tube must be clear of any elec-   trical termination and not kinked.   7. Fasten the new control thermostat to its bracket.   8. Refer to Fig. 15 when reconnecting the wires.   9. Adjust the control thermostat as required.   a) 120 volts ac for two wire 120 volt models.   b) 208 volts ac for three wire 120/208 volt mod-   els.   3. Disconnect the brewer from the power source.   If voltage is present as described, proceed to #4.   If voltage is not present as described, refer to the   Wiring Diagram and check the brewer wiring harness.   I H O F F   N N HI   U B O F F   B U N N   4. Locate the black wire on the control thermostat.   5. Gently remove the capillary bulb and grommet   from the tank.   6. With a voltmeter, check the voltage across the   black wire of the control thermostat and the white   wire on the tank heater for 120 volt two wire mod-   els or red wire on the tank heater for 120/208 volt   three wire models when the control thermostat is   turned fully clockwise. Connect the brewer to the   power source. The indication must be:   BLK to Tank Heater or   Thermal Fuse on Models   W/Faucet   BLU to Limit Thermostat   P1390   FIG. 15 CONTROL THERMOSTAT TERMINALS   a) 120 volts ac for two wire 120 volt models.   28201 081598   Page 23   SERVICE (cont.)   5. Check the solenoid valve for coil action. Connect   the brewer to the power source, place the ICED/   OFF/HOT switch in the “ICED” position and mo-   mentarily place the start switch in the lower posi-   tion and release. Listen carefully in the vicinity of   the solenoid valve for a “clicking” sound as the   coil magnet attracts.   DILUTION SOLENOID VALVE   6. Disconnect the brewer from the power source.   If the sound is heard as described and water will not   pass through the solenoid valve, there may be a block-   age in the water line before or after the solenoid valve   or, the solenoid valve may require inspection for wear,   and removal of waterborne particles.   If the sound is not heard as described, replace the   solenoid valve.   Removal and Replacement:   1. Remove all wires from the solenoid valves.   2. Turn off the water supply to the brewer.   3. Disconnect the water lines to and from the sole-   noid valves.   4. Remove the two #8-32 keps nuts holding the   mounting bracket to the trunk base.   P1391.60   FIG. 16 DILUTION SOLENOID VALVE   Location:   Viewing the brewer from the rear the dilution so-   lenoid is mounted on the right side of the solenoid   mounting bracket which is secured to the trunk base.   5. Lift out the bracket.   6. Remove the two #10-32 slotted-head screws hold-   ing the solenoid valve to the mounting bracket.   7. Securely install the new solenoid valve to the   mounting bracket.   8. Attach the mounting bracket to the trunk base.   9. Securely fasten the water lines to and from the   solenoid valves.   Test Procedure:   1. Disconnect the brewer from the power source.   2. With a voltmeter, check the voltage across the   white/blue and white/violet wires on the dilution   solenoid terminals when the ICED/OFF/HOT switch   is in the “ICED” position and the start switch is   momentarily placed in the lower position. Con-   nect the brewer to the power source. The indica-   tion must be 120 volts ac for two wire 120 volt   models and three wire 120/208 volt models.   3. Disconnect the brewer from the power supply.   10. Refer to Fig. 17 when reconnecting the wires.   WHI/GRN to Hot Tea   Timer TL 4   WHI/RED to Hot Tea Timer TL 1   WHI/VIO to Dilution Solenoid   If voltage is present as described, proceed to #4.   If voltage is not present as described, refer to the Wir-   ing Diagram and check the wiring harness.   WHI/VIO to Iced Tea Brew Timer TL 1   WHI/BLU to Iced Tea Timer TL 4   WHI/VIO to Iced Tea   Brew Timer TL 1   4. Remove both wires from the coil and check for   continuity across the coil terminals.   HOT TEA BREW   SOLENOID   ICED TEA BREW   SOLENOID   If continuity is present as described, reconnect the   white/blue and white/violet wires and proceed to #5.   If continuity is not present as described, replace the   solenoid valve.   WHI/BLU to Iced   Tea Timer TL 4   DILUTION   SOLENOID   P1364   FIG.17 SOLENOID VALVE TERMINALS   28201 081598   Page 24   SERVICE (cont.)   5. With a voltmeter, check the voltage across the ex-   posed terminal of the limit thermostat and the   white wire from the power cord or the red wire   from the terminal block. Connect the brewer to   the power source. The indication must be:   a) 120 volts ac for two wire 120 volt models.   b) 208 volts ac for three wire 120/208 volt mod-   els.   LIMIT THERMOSTAT   6. Disconnect the brewer from the power source.   If voltage is present as described, reconnect the blue   wire to the limit thermostat. The limit thermostat is   operating properly.   If voltage is not present as described, replace the limit   thermostat.   Removal and Replacement   1. Remove both wires from the limit thermostat ter-   minals.   2. Carefully slide the limit thermostat out from un-   der the retaining clip.   3. Carefully slide the new limit thermostat into the   retaining clip.   P2213.60   FIG. 18 LIMIT THERMOSTAT   Location:   The limit thermostat is located inside the hood on   the tank lid.   4. Refer to Fig. 19 when reconnecting the wires.   Test Procedure:   BLU to   1. Disconnect the brewer from the power source and   remove the black wire from the limit thermostat.   2. With a voltmeter, check the voltage across the   black wire removed from the limit thermostat and   the white wire or red wire on the tank heater ter-   minal. Connect the brewer to the power source.   The indication must be:   Control   Thermostat   a) 120 volts ac for two wire 120 volt models.   b) 208 volts ac for three wire 120/208 volt mod-   els.   BLK to Power Cord   or Terminal Block   3. Disconnect the brewer to from the power source.   P1800   FIG. 19 LIMIT THERMOSTAT TERMINALS   If voltage is present as described, reconnect the black   wire and proceed to #4.   If voltage is not present as described, refer to the Wir-   ing Diagram and check the wiring harness.   4. Remove the blue wire from the limit thermostat.   28201 081598   Page 25   SERVICE (cont.)   If voltage is present as described, proceed to #6.   If voltage is not present as described, refer to the Wir-   ing Diagram and check the wiring harness.   ICED/OFF/HOT SWITCH   6. Check for continuity across the center and left ter-   minals of the top row when switch is in the "ICED"   position and the center and right terminals of the   top row when the switch is in the "HOT” position.   If continuity is present as described, replace the wires,   the switch is operating properly.   If continuity is not present as described, replace the   switch.   Removal and Replacement:   1. Remove the wires from the switch terminals.   2. Compress the clips inside the hood and gently   push the switch through the opening.   3. Push the new switch into the opening and spread   the clips to hold the switch captive in the hood.   4. Refer to FIG. 21 when reconnecting the wires.   BLK to Limit Thermostat (120V   or 120/208V Models)   WHI/VIO to Iced Tea   Brew Timer TL1   WHI/RED to Hot Tea   Brew Timer TL1   P1370.40   FIG. 20 ICED/OFF/HOT SWITCH   Location:   The ICED/OFF/HOT switch is located in the front   of the hood, above and to the left of the brew funnel.   WHI to Iced Tea Brew Timer TL2   (120V or 120/208V Models)   Test Procedure:   P1367   1. Disconnect the brewer from the power source.   2. Remove the black and white/violet wires from the   switch terminals.   FIG.21 ICED/OFF/HOT SWITCH TERMINALS   3. With a voltmeter, check the voltage across the   black wire removed from the ICED/OFF/HOT switch   and the white wire remaining on the switch termi-   nal.   4. Connect the brewer to the power source.The indi-   cation must be 120 volts ac for two wire 120 volt   models and three wire 120/208 volt models,   5. Disconnect the brewer from the power source.   28201 081598   Page 26   SERVICE (cont.)   START SWITCH   4. Check for continuity across the two terminals on   the left side of the switch when it is held in the   lower position. Continuity must not be present   across these terminals in the upper position.   If continuity is present as described, reconnect the   wires, the switch is operating properly.   If continuity is not present as described, replace the   switch.   Removal and Replacement:   1. Remove the wires from the switch terminals.   2. Compress the clips inside the hood and gently   push the switch through the opening.   3. Push the new switch into the opening and spread   the clips to hold the switch captive in the hood.   4. Refer to Fig. 23 when reconnecting the wires.   WHI/ORN to Hot   Tea Brew Timer TL3   ORN to Iced Tea   Brew Timer TL3   WHI/YEL to   Hot Tea Brew   Timer TL5   YEL to Iced Tea   Brew Timer TL5   P1370.40   P1368   FIG. 22 START SWITCH   FIG. 23 START SWITCH TERMINALS   Location:   The start switch is located in the front of the hood,   above and to the right of the brew funnel.   Test Procedure:   1. Disconnect the brewer from the power source.   2. Remove the wires from all four terminals.   3. Check for continuity across the two terminals on   the right side of the switch when it is held in the   lower position. Continuity must not be present   across these terminals in the upper position.   If continuity is present as described, proceed to #4.   If continuity is not present as described, replace the   switch.   28201 081598   Page 27   SERVICE (cont.)   TANK HEATER   Removal and Replacement:   1. Disconnect the black wire and the white or red   wire from the tank heater terminals.   2. Remove sprayhead and the hex nut securing the   sprayhead tube to the hood. Set aside for reas-   sembly.   3. Disconnect vent tube.   4. Remove the six #10 thread cutting screws secur-   ing the tank lid to the tank.   5. Remove the tank lid with limit thermostat, spray-   head tube, tank heater and vent tube.   6. Remove the two hex nuts securing the tank heater   to the tank lid. Remove tank heater with gaskets   and discard.   7. Install new tank heater with gaskets on the tank   lid and secure with two hex nuts.   P2213.60   8. Install tank lid with limit thermostat, sprayhead   tube, tank heater and vent tube using six #10   thread cutting screws.   9. Secure sprayhead tube to hood using a hex nut.   10. Install sprayhead.   FIG. 24 TANK HEATER   Location:   The tank heater is located inside the tank and se-   cured to the tank lid.   11. Connect vent tube to fitting.   Test Procedures:   12. Reconnect the wires to the limit thermostat and   tank heater. See limit thermostat section in this   manual when reconnecting wires.   13. Refer to Fig.25 when reconnecting the tank heater   wires.   1. Disconnect the brewer from the power supply.   2. With a voltmeter, check the voltage across the   black and white wires on 120 volt models or the   black and red wires for 120/208 volt models with   a voltmeter. Connect the brew to the power source.   The indication must be:   WHI to Power Cord (120V Models)   a) 120 volts ac for two wire 120 volt models .   b) 208 volts ac for three wire120/208 volt mod-   els.   RED to Terminal Block (120/208V   BLK to Control   Models)   Thermostat or   Thermal Fuse   3. Disconnect the brewer from the power source.   If voltage is present as described, proceed to #4   If voltage is not present as described, refer to the Wir-   ing Diagrams and check wiring harness.   4. Disconnect the black wire and the white wire or   red wire from the tank heater terminals.   5. Check for continuity across the tank heater termi-   nals.   If continuity is present as described, reconnect the   wires, the tank heater is operating properly.   If continuity is not present as described, replace the   tank heater.   P1369   FIG. 25 TANK HEATER TERMINALS   NOTE- If the tank heater remains unable to heat, re-   move and inspect heater for cracks in the sheath.   28201 081598   Page 28   SERVICE (cont.)   THERMAL FUSE (Models W/Faucet Only)   Removal and Replacement:   1. Disconnect the thermal fuse from the right tank   heater terminal and the black lead from the con-   trol thermostat.   2. Remove thermal fuse and discard.   3. Connect new thermal fuse to the right tank heater   terminal and the blaclead from the control ther-   mostat   4. Refer to Fig. 27 when reconnecting wires.   BLK Lead from   Control Thermostat   Thermal Fuse   P2213.60   FIG. 26 THERMAL FUSE   Location:   I F H F O N N U B The thermal fuse is located inside the hood con-   nected to the right tank heater terminal.   Tank Heater   Terminals   Test Procedures:   1. Disconnect the brewer from the power source.   2. Disconnect the thermal fuse from the right tank   heater terminal and the black lead from the con-   trol thermostat.   FIG. 27 THERMAL FUSE THERMINALS P1393.70   3. With an ohmmeter, check for continuity across   the thermal fuse terminals.   If continuity is present as described, the thermal fuse   is operating properly.   If continuity is not present as described, replace the   thermal fuse.   28201 081598   Page 29   28201 081598   Page 30   |