OPERATING & SERVICE MANUAL
BUNN-O-MATICCORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
29112.0000C 01/06 ©1998 Bunn-O-Matic Corporation
USER NOTICES (Cont.)
This equipment must be installed to comply with the
Basic Plumbing Code of the Building Officials and
Code Administrators International, Inc. (BOCA) and
the Food Service Sanitation Manual of the Food and
Drug Administration (FDA). For models installed
outside the U.S.A., comply with the applicable
Plumbing /SanitationCode.
00656.0000
00831.0000
27096.0000 FMD-1 ONLY
28368.0001
PUSH and HOLD BUTTON UNTIL CUP
IS 2/3 FULL, THEN RELEASE
PUSH and HOLD BUTTON UNTIL CUP
IS 2/3 FULL, THEN RELEASE
28964.0000
28964.0001
29112 011906
3
INITIAL SET-UP
1. Locate the drip tray assembly beneath the dispenser nested in the packing material.
2. Remove the drip tray and the drip tray cover and set them aside.
3. Remove the water strainer assembly from the drip tray and set it aside.
4. Remove the four legs from the packaging material, apply non-skid pads to the bottom of the legs and
securely install the legs in the dispenser base.
ELECTRICAL REQUIREMENTS
CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up.
The 120 volt version of this dispenser has an attached cordset and requires 2-wire, grounded service rated 120
volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.
The 120/208 and the 120/240 versions of this dispenser has an attched cordset. The mating connector must be
a NEMA 14-20R.
(Refer to the dispenser’s dataplate for exact voltage requirement.)
ELECTRICAL HOOK-UP
CAUTION – Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Open the front door of the dispenser and place the heater switch in the “OFF” (upper position).
4. Connect the dispenser to the power source.
5. If plumbing is to be hooked-up later be sure the dispenser is disconnected from the power source. If
plumbing has been hooked-up, the dispenser is ready for Initial Fill & Heat.
PLUMBING REQUIREMENTS
This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 90 psi
1
(138 and 620 kPa) from a ⁄2" or larger supply line. A shut-off valve should be installed in the line before the
dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345
kPa). The water inlet fitting is 1⁄4" flare.
NOTE - Bunn-O-Matic recommends 1⁄4" copper tubing for installations of less than 25 feet and 3⁄8" for more than
25 feet from the 1⁄2" water supply line. At least 18 inches of an FDA approved flexible beverage tubing, such as
reinforced braided polyethylene or silicone, before the brewer will facilitate movement to clean the countertop.
Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The size and shape of the hole
made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building
Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanita-
tion Manual of the Food and Drug Administration (FDA). For models installed outside the
U.S.A., you must comply to the applicable Plumbing/Sanitation Code for your area.
PLUMBING HOOK-UP
1. Securely attach the short piece of tubing on the water strainer assembly to the inlet fitting on the bottom of
the dispenser.
2. Flush the water line and securely attach it to the flare fitting on the water strainer assembly.
3. Turn-on the water supply.
29112 011906
4
INITIAL FILL & HEAT
CAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except
when specified in the instructions.
1. Turn-on the water supply and connect the dispenser to the power source.
2. Water will automatically flow into the tank to the proper level and then shut-off. This will take less than five
minutes.
3. When the tank is full of water, open the front door and place the heater switch in the “ON” (lower) position.
A tank full of cold water will take approximately forty minutes for the water to heat on 120 volt versions or
twenty minutes for 120/208 volt versions and 120/240 volt versions.
During this waiting period, complete these dispenser set-up steps:
a. Place the drip tray in front of the dispenser. Set the drip tray cover in place.
b. Placeasetofkeyholesinthecuplocatorplateoverthescrewsbeneaththehopperaccessdoorandpushdown
gently.
c. Fill the hopper with the dry product to be dispensed.
LIQUID LEVEL CONTROL
The system automatically maintains the hot water tank’s level by energizing the refill solenoid when the water
level drops below the liquid level probe. If the system for the FMD-2 only has not successfully refilled in 7 1/2
minutes, a refill error occurs.
When a refill error occurs, the refill solenoid is de-energized and the rinse L.E.D. will flash about once every
5 seconds.
Once the cause of the refill error has been investigated (see the troubleshooting guide in the Operating and
Service Manual) and cured, the system can be reset by disconnecting (for at least 5 seconds) and then
reconnecting the power to the machine.
RINSE TIMER (FMD-2 ONLY)
The dispenser is shipped from the factory with the rinse timer disabled. To enable the rinse timer, remove
power from the dispenser, remove the lower access panel, and remove the jumper from J1 of the control board.
Replace the lower access panel, and return power to the dispenser.
When enabled, the rinse timer automatically keeps track of the time since the dispenser was last run through
a rinse sequence. If the dispenser detects that a rinse sequence has not been run for 8 hours, the rinse L.E.D. will
flash continually. If, after an additional 4 hours (12 hours total), a rinse sequence has still not been run, the rinse
L.E.D. will light continuously, and the hopper drives will be disabled until a rinse sequence has been run.
RUNNING A RINSE SEQUENCE
1. Place the rinse/run switch in the rinse position.
2. Sequentially, or simultaneously, at each of the two positions (FMD-2 only) dispense for at least 10 seconds.
3. After the rinse L.E.D. has extinguished, the rinse timer is reset (FMD-2 only).
4. Return the rinse/run switch to the run position.
DISPENSER USE
1. Simply place a cup on the drip tray beneath the dispensing tip.
2. Press the button to froth and dispense the beverage.
3. Release the button when the cup is approximately 2/3 full and allow the mixing chamber to drain.
NOTE - The mixing chamber must drain at the end of each dispense.
29112 101598
5
COLD BEVERAGE SET-UP (OPTIONAL FMD-2 ONLY)
Cold beverages may be dispensed from the left dispense position as follows:
1. Disconnect the dispenser from the power source.
2. Remove the lower front access panel.
3. Locate the Hot/Cold jumper connection near the whipper panel in the main wiring harness.
4. Remove the Hot jumper connection (red jumper plug) from the main wiring harness and connect the Cold
jumper connection (blue jumper plug) to the main harness.
5. Replace the lower front access panel and reconnect the dispenser to the power source.
CLEANING
Refer to the decal on the rear of the dispenser door for cleaning recommendations and proccedures.
Theuseofadampclothrinsedinanymild, non-abrasive, liquiddetergentisrecommendedforcleaningallsurfaces
on Bunn-O-Matic equipment.
ADJUSTMENTS
The beverage solenoid is preset to dispense approximately one ounce per second. This amount can be adjusted:
1. Disconnect the dispenser from the power source.
2. Remove product hopper(s).
3. Remove the hole plug(s) in the auger motor mounting panel.
4. Rotatethecontrolatthebaseofthesolenoidclockwisetodecreaseorcounterclockwisetoincreasetheamount
of water.
5. Reinstall plug(s) and hopper(s).
HOPPER MOTOR SPEED ADJUSTMENT (FMD-1)
The hopper dispense rate is preset at the factory. With 8 tooth gear and auger wire the preset dispense rate is
approximately 3 to 5 grams per second. With 12 tooth gear and auger wire the preset dispense rate is approxi-
mately 5 to 7 grams per second. The hopper dispense rate can be adjusted to a range of dispense rates from
approximately 1.5 to 12 grams per second, as follows:
1. Set the tank heater switch to the off position.
2. Open the top front cover of the dispenser and remove the two screws securing the top cover.
3. Remove the top cover assembly and set it aside.
4. Locate the motor speed adjuster (leftmost) on the dispenser cabinet top cross member.
5. Using extreme care not to touch the live terminals of the tank heater, adjust the motor speed by rotating the
motor speed adjuster to the desired point, ranging from minimum (full counterclockwise) to maximum
(full clockwise.)
6. After the motor adjustment is complete, replace the top cover assembly, securing it with the two screws,
and return the tank heater switch to the on position.
29112 011906
6
HOPPER MOTOR SPEED PROGRAMING (FMD-2)
The hopper dispense rate is preset at the factory. With 22 tooth gear and auger wire the preset dispense rate is
approximately3to5gramspersecond.With32toothgearandaugerwirethepresetdispenserateisapproximately
5to7gramspersecond. Thehopperdispenseratecanbeadjustedtoarangeofdispenseratesfromapproximately
1.5 to 12 grams per second, as follows:
1. Place the rinse/run switch in the center (program) position.
2. Place the increase/decrease switch in the desired (increase or decrease) position.
3. Press and release the dispense switch for the chamber you wish to adjust. Each time the dispense switch is
pressed, the rinse L.E.D. will flash, and the motor speed for that hopper will be increased/decreased by
approximately 2 1/2%.
4. Return the rinse/run switch to the run position after hopper motor speed adjustments are complete.
DRAINING THE HOT WATER TANK
CAUTION - The dispenser must be disconnected from the power source throughout these steps.
1. Disconnect the dispenser from the power source.
2. Open front door and place tank heater switch in the “OFF” (upper) position.
3. Shut-off and disconnect the incoming water supply.
4. Remove the top panel.
5. Gently remove one of the grommets from the tank lid.
6. Insert a tube to the bottom of the tank and syphon ALL of the water out.
NOTE - The dispenser must be refilled using the INITIAL FILL & HEAT steps before reconnecting to the power
source.
29112 011906
7
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
•
•
Inspection, testing, andrepairofelectricalequipmentshouldbeperformedonlybyqualifiedservicepersonnel.
All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
•
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
•
•
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
Theuseoftwowrenchesisrecommendedwheneverplumbingfittingsaretightenedorloosened. Thiswillhelp
to avoid twists and kinks in the tubing.
•
•
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
This unit is heated at all times. Keep away from combustibles.
WARNING – • Exercise extreme caution when servicing electrical equipment.
• Unplug the dispenser when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices
REMEDY
PROBLEM
PROBABLE CAUSE
Water lines and valves to the dis-
penser must be open.
Product will not dispense
1. No water
(A1) Check for 120 volts across the
black and white wires on two wire
120 volt dispensers.
2. No power or incorrect voltage to
the dispenser
(A2) Check for 120 volts across the
red and white wires and the black
and white wires, 208 volts across
the red and black wires on three wire
120/208 volt dispensers and 240
volts across the red and black wires
on three wire 120/240 volt dispens-
ers.
(B) Check circuit breakers or fuses.
Refer to Service - Dispense Switch
for testing procedure. See page 22
3. Dispense Switch
RefertoService-DispenseSolenoid
Valve for testing procedures. See
page 35
4. Dispense Solenoid Valve
29112 101598
8
TROUBLESHOOTING (cont.)
PROBLEM
Product will not dispense (cont.)
PROBABLE CAUSE
5. Solenoid Valve (Inlet)
REMEDY
Refer to Service - Solenoid Valve
(Inlet) for testing procedures. See
page 36
6. A) Level Control Board and Probe RefertoService-LevelControlBoard
- FMD-1
and Probe for testing procedures.
See page 30
B)ControlBoardandProbe-FMD- Refer to Service - Control Board and
2
Probe for testing procedures. See
page 20
7. A) Auger Drive - FMD-1
Refer to Service - Auger Drive. See
page 13
B) Auger Drive - FMD-2
8. Water Strainer
Refer to Service - Auger Drive. See
Page 15
(A) Direction of flow arrow must be
pointing towards dispenser.
(B) Remove the strainer and check
for obstructions. Clear or replace.
9. Lime build-up
Inspectthetankassemblyforexces-
CAUTION - Tank and tank compo- sive lime deposits. Delime as re-
nents should be delimed regularly quired.
dependingonlocalwaterconditions.
Excessivemineralbuild-uponstain-
lesssteelsurfacescaninitiatecorro-
sive reactions resulting in serious
leaks.
10. Transformer - FMD-2
Refer to Service - Transformer for
testing procedures. See page 39
1. Limit Thermostat
Refer to Service - Limit Thermostat
Water is not hot
CAUTION - Do not eliminate or by- for testing procedures. See page 32
passlimitthermostat.UseonlyBOM
replacement part #29329.1000
2. Control Thermostat
Refer to Service - Control Thermo-
statfortestingprocedures.Seepage
19
3. Tank Heater
Refer to Service - Tank Heater for
testing procedures. See page 37
29112 051200
9
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
Water is not hot (Cont.)
4. Tank Heater Switch
RefertoService -TankHeaterSwitch
for testing procedures. See page 38
Spitting or excessive steaming
1. Lime build-up
Inspectthetankassemblyforexces-
CAUTION - Tank and tank compo- sive lime deposits. Delime as re-
nents should be delimed regularly quired.
dependingonlocalwaterconditions.
Excessivemineralbuild-uponstain-
lesssteelsurfacescaninitiatecorro-
sive reactions resulting in serious
leaks.
2. Control Thermostat
Refer to Service - Control Thermo-
stat for testing procedures. See
page 19
Dripping from dispense tip
1. Lime build-up
Inspectthetankassemblyforexces-
CAUTION - Tank and tank compo- sive lime deposits. Delime as re-
nents should be delimed regularly quired.
dependingonlocalwaterconditions.
Excessivemineralbuild-uponstain-
lesssteelsurfacescaninitiatecorro-
sive reactions resulting in serious
leaks.
2. Dispense Solenoid Valve
Removethedispensesolenoidvalve
and clear any obstructions. Rebuild
orreplacethevalveifnecessary.See
page 35
Water flows into tank continuously
1. A) Level Control Board and Probe RefertoService-LevelControlBoard
- FMD-1
and Probe for testing procedures.
See page 30
B)ControlBoardandProbe-FMD- Refer to Service - Control Board and
2
Probe for testing procedures. See
page 20
2. Solenoid Valve (Inlet)
Refer to Service - Solenoid Valve
(Inlet) for testing procedures. See
page 36
29112 101598
10
TROUBLESHOOTING (cont.)
PROBLEM
REMEDY
PROBABLE CAUSE
Product overflows container
Refer to Service - Dispense Switch
for testing procedures. See page 22
1. Dispense Switch
Removethesolenoidvalveandclear
anyobstructions. Rebuildorreplace
the valve if necessary. See page 35
2. Dispense Solenoid Valve
1. Water Temperature
Weak product
Place an empty container beneath
the dispense tip. Initiate a dispense
cycle and check the water tempera-
tureimmediatelybelowthedispense
tip with a thermometer.
Reading for mechanical thermostat
models should be 180°F to 200°F
(seethermostattemperaturesettings
decal in USER NOTICES on page 3.)
Referto Service-WhipperMotorfor
testing procedure. See page 25
2. Whipper Motor
3. Frother
Refer to Service - Frother Compo-
nents. See page 25
RefertoService-DispenseSolenoid
Valve for test procedures. See page
35
4. Dispense Solenoid Valve
Refer to Service - Auger Drive Com-
ponents. See page 13
See page 15
5. Auger Drive - FMD-1
Auger Drive - FMD-2
Refer to Service - Auger Drive Com-
ponents. See page 13
See page 15
6. Auger Spring - FMD-1
Auger Spring - FMD-2
7. Auger Motor - FMD-1
Auger Motor - FMD-2
Refer to Service - Auger Drive Com-
ponents. See page 13
See page 15
Refer to Service - Rinse/Run Switch
for test procedures. See page 31
See page 33
8. Rinse/Run Switch - FMD-1
Rinse/Run Switch - FMD-2
9. Rinse Timer - FMD-2
Refer to Operation - Rinse Timer.
See Page 5
29112 101598
11
TROUBLESHOOTING (CONT.)
PROBLEM
REMEDY
PROBABLE CAUSE
Plumbing lines should not be rest-
ing on the counter top.
1. Plumbing Lines
Dispenser is making unusual
noises
(A)Thedispensermustbeconnected
to a cold water line
2. Water Supply
(B) Water pressure to the dispenser
must not exceed 90 psi (620 kPa).
Install a regulator if necessary to
lower the working pressure to ap-
proximately 50 psi (345 kPa).
Remove and clean lime off the tank
heater. See page 37
3. Tank Heater
Refer to Service - Fan for testing
procedures. See page 24
1. Fan
Excess dust
RefertoService-HopperDriveBoard
for testing procedures. See page 27
2. A) Hopper Drive Board - FMD-1
B) Control board - FMD-2
1. Lamp
Refer to Service - Control Board for
testing procedures. See page 20
RefertoService- Lamp,seepage29
for lamp replacement.
Display not lit
Refer to Service - Lamp Holder for
testing procedures. See page 29
2. Lamp Holder
3. Starter - Lamp
4. Ballast
Refer to Service - Starter for testing
procedures. See page 30
Refer to Service - Ballast for testing
procedures. See page 19
29112 051200
12
AUGER DRIVE COMPONENTS FMD-1
SERVICE
This section provides procedures for testing and
replacing various major components used in this
dispenser should service become necessary. Re-
fer to Troubleshooting for assistance in determin-
ing the cause of any problem.
WARNING - Inspection, testing, and repair of electri-
cal equipment should be performed only by quali-
fied service personnel. The dispenser should be
unplugged when servicing, except when electrical
tests are required and the test procedure specifi-
cally states to plug-in the dispenser.
COMPONENT ACCESS
WARNING-Disconnectthedispenser fromthepower
source before the removal of any panel or the
replacement of any component.
All components are accessible by opening the
door, removal of the door panels, dispenser top
covers, hopper(s), hopper support plate, splash
guard, splashpanelw/driptray, lowerfrontaccess
panel and rear access cover.
Refer to the contents listing for component loca-
tion.
P1665
FIG. 1 AUGER DRIVE COMPONENTS
Location
The auger components are located inside the
bottom part of the hopper except for the auger drive
bracket, spacer and retaing clip, which are located on
the outside rear of the hopper base. The auger motor
is located on the lower right rear of the motor
mounting panel. Refer to Fig. 2 for disassembly and
assembly.
Contents
Auger Drive Components (FMD-1) .......................13
Auger Drive Components (FMD-2) .......................15
Ballast...................................................................18
Control Thermostat...............................................19
Control Board (FMD-2) .........................................20
Dispense Switch ...................................................22
Fan........................................................................24
Frother ..................................................................25
Hopper Drive Board(FMD-1).................................27
Increase/Decrease Switch (FMD-2) ......................28
Lamp Holder .........................................................29
Lamp ....................................................................29
Lamp Starter and Socket ......................................30
Level Control Board and Level Probe (FMD-1) .....30
Limit Thermostat ..................................................32
Rinse/Run Switch (FMD-1)...................................32
Rinse/Run Switch (FMD-2)...................................33
Solenoid (Cold Water - Optional FMD-2 Only) ......34
Solenoid (Dispense) .............................................35
Solenoid (Inlet) .....................................................36
Tank Heater...........................................................37
Tank Heater Switch ...............................................38
Transformer (FMD-2)............................................39
Whipper Motor .....................................................26
Wiring Diagram ...............................................40,41
Test Procedures - Auger Motor
1. Disconnect the dispenser from the power source.
2. Disconnect the white/red wire and the white wire
from the hopper speed control board.
3. Check the voltage across the white/red wire and
the white wire with a voltmeter. With the rinse/
run switch in the run (lower) position, connect
the dispenser to the power supply. The indica-
tion must be :
a) 120 volts ac for two wire 120 volt models.
b) 120 volts ac for three wire 120/208 volt or
120/240 volt models.
4. Disconnect the dispenser from the power sup-
ply.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the wir-
ing diagram and check the dispenser wiring harness.
29112 101598
13
SERVICE
AUGER DRIVE COMPONENTS - FMD-1 (CONT.)
1
2
5. Check the voltage across the positive (red wire)
terminal and the negative (black wire) terminal on
the auger motor with a voltmeter. With the rinse/
run switch in the run (lower) position press and
hold the dispense switch. Connect the dispenser
to the power supply. After a .6 second delay the
indication must be 4.0 to 24.5 volts dc.
3
4
5
7
If voltage is present as described, the auger motor
drive is operating properly. If auger does not turn,
replace the auger motor.
If voltage is not present as described, replace the
auger hopper drive board.
13
14
15
8
9
10
11
Removal, Cleaning and Replacement
Hopper & Auger
1. Open the dispenser door and raise the top front
cover.
6
Early Models
2. Lift the hopper assy (17) over the pins (16) on
hopper support plate (12) and slide hopper as-
sembly out the front of the dispenser.
3. Remove hopper lid (1) and empty product.
4. Pull off the ejector elbow (15).
17
5. Remove retainer clip (11) and washer (10) from
the bottom of the hopper base (9).
6. Remove whipper shaft (3), wiper blade (4) and
wiper drive gear (5) from the hopper base (9).
7. Remove auger wire (14) by pulling it out the front
of the hopper base (9).
8. On Early models, remove auger drive shaft (13) by
removing the retaining clip (6) from auger drive
shaft. On Late models, remove the auger drive
bracket (7) by unscrewing left hand threads from
the auger shaft (13).
9. Slide spacer (8) and auger drive shaft bracket (7)
off of the auger drive shaft (13).
10. Remove auger drive shaft (13) from hopper base
(9).
11. Washcomponentsinamildsolutionofdishdeter-
gent using a bristle brush when needed.
12. Rinse and dry each item thoroughly.
13. Check for damaged or broken components, re-
place any if necessary and reassemble hopper
assembly.
14. Installhopperassy(17)in thedispenserbysliding
hopperassy onthehoppersupportplate(12)until
the slot in the rear of the hopper base (9) seats
against the pins (16) in the hopper support plate
(12).
12
16
18 19 20 21
FIG. 2 AUGER DRIVE & HOPPER DISASSEMBLY
P1667
1. Hopper Lid
2. Hopper
12. Hopper Support Plate
13. Auger Drive Shaft
14. Auger Wire
15. Ejector Elbow
16. Hopper Locating Pins
17. Hopper Assembly
18. Auger Motor Bracket
19. Auger Motor
3. Wiper Shaft
4. Wiper Blade
5. Wiper Drive Gear
6. Retainer Clip
7. Auger Drive Bracket
8. Spacer
9. Hopper Base
10. Washer
11. Retainer Clip
20. Dust Seal
21. Auger Motor Mount-
ing panel
29112 011906
14
AUGER DRIVE COMPONENTS - FMD-2
SERVICE (cont.)
AUGER DRIVE COMPONENTS - FMD-1 (cont.)
Auger Drive Motor (Refer to Fig. 2)
1. Remove hopper assy (17), and set aside for reas-
sembly.
2. Remove the four #8-32 screws securing the hop-
per support plate (12), remove plate and set aside
for reassembly.
3. Remove the four #8-32 screws, located inside the
dispenser housing on the lower right front of the
auger motor mounting panel (21), securing auger
motor mounting bracket (18) and auger motor
(19) to the rear of the auger motor mounting panel
(21).
4. Disconnect the wires from the hopper drive board.
5. Remove auger motor mounting bracket (18), au-
ger motor (19) and dust seal (20) as an assembly.
6. Remove dust seal (20) from auger motor (19).
7. Disconnect the wires from the auger motor (19).
8. Removethefour#8-32screwssecuringthe auger
motor (19) to the auger motor mounting bracket
(18).
2
J
J4
J3
9. Remove auger motor (19) and discard.
10. Using four #8-32 screws install new auger motor
(19) on mounting bracket (18).
11. Install dust seal (20) on auger motor shaft and
align notch in seal with motor casting.
12. Reconnect the wires to the terminals on the hop-
per drive board.
13. Refer to Fig. 3 when reconnecting wires.
14. Using four #8-32 locking screws install auger
motor, dust seal and mounting bracket to the rear
of the auger motor mounting panel (21).
15. Install hopper assy (17).
P1666
FIG. 4 AUGER DRIVE COMPONENTS
Location
The auger components are located inside
the bottom part of the hopper except for the auger
drive bracket, washer and locknut, which are located
on the outside bottom rear of the hopper. The auger
motors are located on the rear of the auger motor
mounting panel. Refer to Fig. 5 for disassembly and
assembly.
Test Procedures - Auger motors
1. Disconnect the dispenser from the power source.
2. Disconnect the wires from the motor to be tested.
3. Check the voltage across the positive (white/or-
ange) wire for the right motor, or the positive
(white/red) wire for the left motor and the negative
(green) wire with a voltmeter. With the rinse/run
switch in the run (lower) position press and hold
the appropriate dispense switch. Connect the dis-
penser to the power supply. After a .6 second
delay the indication must be 4.0 to 24.5 volts dc.
REDtoHopperSpeed
Control Board (+)
BLK to Hopper Speed
Control Board (-)
P1639
FIG. 3 AUGER MOTOR TERMINALS
29112 101598
15
SERVICE (cont.)
AUGER DRIVE COMPONENTS - FMD-2 (CONT.)
1
2
4
4. Disconnect the dispenser from the power supply.
11
6
If voltage is present as described and the auger does
not turn, replace the auger motor.
If voltage is not present as described, refer to the wir-
ing diagrams and check the dispenser wiring harness.
3
5
7
Removal, Cleaning and Replacement
Hopper & Auger (Early Models)(Refer to Fig. 5)
1. Open the dispenser door and raise the top front
cover.
2. Lift the front edge of hopper assy (20) over the
tab on hopper support plate (19) and slide hop-
per assembly out the front of the dispenser.
3. Remove hopper lid (1) and empty product.
4. Pull off the ejector elbow (13).
12
13
8
9
10
20
5. Remove agitator disc assy (2) by pulling agitator
support rod (4) towards agitator disc assy and
lifting agitator disc assy from hopper (10).
6. Remove auger (12) by pulling it out the front of
the hopper (10).
7. Remove auger drive shaft (5) by removing the
retaining clip (6) from auger drive shaft.
8. Slide washer (8) and auger drive shaft bracket
(7) off of the auger drive shaft (5).
9. Slide auger drive shaft (5) from auger drive shaft
bushing (3) and remove from hopper (10).
10. Remove locknut (9) from auger drive shaft bush-
ing (3) and remove auger drive shaft bushing
from hopper (10).
15 16 17 14 18 19
11. Wash components in a mild solution of dish de-
tergent using a bristle brush when needed.
12. Rinse and dry each item thoroughly.
13. Check for damaged or broken components, re-
place any if necessary and reassemble hopper
assy.
14. Installhopperassy(20)in thedispenserbysliding
hopper assy in the guides on the hopper support
plate (19) until the slot in the bottom rear the
hopper seats against the pin (18) in the hopper
support plate.
P1673
FIG. 5 AUGER DRIVE & HOPPER DISASSEMBLY
11. Spring
12. Auger Wire
13. Ejector Elbow
1. Hopper Lid
2. Agitator Disc Assy
3. Auger Drive Shaft
Bushing
4. Agitator Support Rod
5. Auger Drive Shaft
14. Auger Motor Mount-
ing Panel
15. Auger Motor Bracket
16. Auger Motor
6. Retainer Clip
17. Dust Seal
7. Auger Drive Bracket
18. Pins
8. Washer
9. Locknut
10. Hopper
19. Hopper Support plate
20. Hopper Assy
29112 011906
16
SERVICE (cont.)
AUGER DRIVE COMPONENTS - FMD-2 (cont.)
1
2
Removal, Cleaning and Replacement
4
5
Hopper & Auger (Late Models)(Refer to Fig. 6)
1. Open the dispenser door and raise the top front
cover.
2. Lift the front edge of hopper assy (20) over the
tab on hopper support plate (19) and slide hop-
per assembly out the front of the dispenser.
3. Remove hopper lid (1) and empty product.
4. Pull off the ejector elbow (13).
5. Remove agitator disc assy (2) by pulling agitator
support rod (4) towards agitator disc assy and
lifting agitator disc assy from hopper (10).
6. Remove auger (12) by pulling it out the front of
the hopper (10).
7. Remove auger drive shaft (5) by removing the
retaining clip (6) from auger drive shaft.
8. Slide washer (8) and auger drive shaft bracket
(7) off of the auger drive shaft (5).
3
8
7
6
9
10
11
9. Slide auger drive shaft (5) from auger drive shaft
bushing (3) and remove from hopper (10).
10. Remove locknut (9) from auger drive shaft bush-
ing (3) and remove auger drive shaft bushing
from hopper (10).
11. Wash components in a mild solution of dish de-
tergent using a bristle brush when needed.
12. Rinse and dry each item thoroughly.
13. Check for damaged or broken components, re-
place any if necessary and reassemble hopper
assy.
14 15 16 12 13
P3567
14. Installhopperassy(20)in thedispenserbysliding
hopper assy in the guides on the hopper support
plate (19) until the slot in the bottom rear the
hopper seats against the pin (18) in the hopper
support plate.
FIG. 6 AUGER DRIVE & HOPPER DISASSEMBLY
1. Hopper Lid
2. Mixing Blade
3. Agitator Disk
4. Auger Drive Shaft
Bushing
9. Auger Wire
10. Ejector Elbow
11. Hopper Assy
12. Auger Motor Mounting
Panel
5. Auger Drive Shaft
6. Locknut
7. Auger Drive Bracket
8. Hopper
13. Hopper Support Plate
14. Auger Motor Bracket
15. Auger Motor
16. Dust Seal
29112 011906
17
SERVICE (cont.)
LEFT
AUGER DRIVE COMPONENTS - FMD-2 (cont.)
RIGHT
Auger Drive Motor (Refer to Fig. 5 or 6)
1. Remove all hopper assemblies (20) and set aside
for reassembly.
2. Remove the four #8-32 screws securing the hop-
per support plate (19), remove plate and set aside
for reassembly.
3. Remove the four #8-32 locking screws, located
inside the dispenser housing on the front of the
auger motor mounting panel (14), securing auger
motor mounting bracket (15) and auger motor
(16) to the rear of the auger motor mounting panel
(14).
RED to WHI/ORN from
Control Board J3-2
BLK to GRN from
Control Board J3-4
4. Disconnect the wires from the auger motor (16) to
be removed.
BLK to GRN from
Control Board J3-4
RED to WHI/RED from
Control Board J3-3
5. Remove auger motor mounting bracket (15), au-
ger motor (16) and dust seal (17) as an assembly.
6. Remove dust seal (17) from auger motor (16).
7. Remove the four #8-32 screws securing the auger
motor to the auger motor mounting bracket.
8. Remove auger motor and discard.
9. Using four #8-32 screws install new auger motor
(16) on mounting bracket (15).
P1639
FIG. 7 AUGER MOTOR TERMINALS
BALLAST - FMD-1 & FMD-2
10. Install dust seal (17) on auger motor shaft.
11. Using four #8-32 locking screws install auger
motor, dust seal and mounting bracket to the rear
of the auger motor mounting panel (14)
12. Reconnect the wires to the terminals on the auger
motor.
13. Install hopper support plate (19) and all hopper
assemblies (20).
14. Refer to Fig. 7 when reconnecting wires.
FMD-1
P1665
1
J2
J4
J3
FMD-2
P1666
FIG. 8 BALLAST
29112 101598
18
tightenthetwo#8-32screwssecuringthecompo-
nent bracket to the dispenser housing base.
SERVICE (cont.)
BALLAST - FMD-1 & FMD-2 (cont.)
Location
FMD-1
BLK to BLK
from Main
Wiring Harness
The front door lamp ballast is located behind
the front access panel on the left front side of the com-
ponent bracket.
BLK to BLU from
Main Harness
FMD-2
The front door lamp ballast is located behind
the front access panel on the left rear side of the com-
ponent bracket.
P1447
FIG. 9 BALLAST TERMINALS
CONTROL THERMOSTAT - FMD-1 & FMD-2
Test Procedure
1. Disconnect the dispenser from the power source.
2. Disconnect the two black lead on the ballast from
the main harness.
3. Check for continuity between the two black leads
on the ballast.
If continuity is present as described the ballast is
operating properly.
If continuity is not present as described, replace the
ballast.
Removal and Replacement
FMD-1
1. Disconnect the wires from the ballast.
2. Remove the two #8-32 screws securing the bal-
last to the component bracket.
3. Remove and discard ballast.
4. Using two #8-32 screws install new ballast on the
component bracket.
P1665
FIG. 10 CONTROL THERMOSTAT
Location
The control thermostat is located under the
front tank mounting bracket on the upper right side of
the dispenser housing.
5. Refer to the Fig. 9 when reconnecting the wires.
FMD-2
1. Loosen the two #8-32 screws securing the com-
ponent bracket to the dispenser housing base.
2. Pull component bracket out the front of the dis-
penser far enough so the leads on the ballast can
bedisconnectedfromthemainwiringharnessand
the door interconnect harness.
3. Removethetwo#8-32screwssecuringtheballast
the rear of the component bracket.
4. Remove and discard ballast.
5. Install new ballast on the rear of the component
bracket and secure with two #8-32 screws.
6. Refer to Fig. 9 and reconnect the wires.
7. Place the component bracket into position and
Test Procedure
1. Disconnect the dispenser from the power source.
2. Disconnect the black wire of the control thermo-
stat from the black lead from the limit thermostat.
3. Remove bulb from the tank.
4. Check the voltage across black wire on the control
thermostat and the white or red wire on the tank
heater with the tank heater switch in the “ON”
lower position with a voltmeter. Connect the dis-
penser to the power source. The indication must
be:
29112 101598
19
CONTROL BOARD - FMD-2 ONLY
SERVICE (cont.)
CONTROL THERMOSTAT - FMD-1 & FMD-2 (cont.)
a) 120 volts ac for two wire 120 volt models.
b)208voltsacforthreewire120/208volt models.
c) 240 volts ac for three wire 120/240 volt models.
5. Disconnect the dispenser from the power source.
If voltage is present as described the control thermo-
stat is operating properly. Reinstall bulb into the tank.
If voltage is not present as described, replace the
thermostat.
Removal and Replacement.
1. Remove the thermostat capillary bulb by firmly
pulling-up on the capillary at the tank lid. This will
disengage the grommet from the tank lid.
2. Loosen the two #6-32 screws securing the ther-
mostat to the front tank mounting bracket.
3. Disconnect the wires from the thermostat.
4. Remove thermostat and remove the screws and
spacers from the thermostat.
J2
J4
J3
5. Discard thermostat.
6. Install two spacers and two #6-32 screws on the
new thermostat.
7. Position the thermostat on the botttom side of the
front tank mounting bracket and tighten the two
#6-32 screws.
8. Slide the grommet to the line 4.5" above the bulb
on the new capillary tube.
P1666
FIG. 12 CONTROL BOARD
Location:
The Control Board is located behind the lower
frontaccesscovermountedonthecomponentbracket.
9. Insert the capillary bulb through the hole in the
tank lid and press the grommet firmly and evenly
so that the groove in the grommet fits into the tank
lid.
10. Carefully bend the capillary tube so that the tube
and bulb inside the tank are in the vertical position
and away from any electrical connections.
11. Refer to Fig. 11 and reconnect the wires.
NOTE - The capillary tube must be clear of any electri-
cal termination and not kinked.
Test Procedure:
Liquid Level Control Circuitry:
1. Disconnect the dispenser from the power source.
2. Disconnect the six pin connector from J3 of the
control board.
3. Check the voltage across pins 5 & 6 of the six pin
connector on the wiring harness with a voltmeter.
Connect the dispenser to the power source. The
indication must be 24 volts ac.
4. Disconnect the dispenser from the power source.
BLK from Limit
Thermostat
If voltage is present as described, proceed to step 5.
If voltage is not present as described, refer to the
wiring diagram and check the dispenser wiring har-
ness.
5. Reconnect the six pin connector of the wiring
harness to J3 of the control board.
BLK from Tank
Heater Switch
P1668
FIG. 11 THERMOSTAT TERMINALS
29112 101598
20
SERVICE (cont.)
16. Reconnect the ten pin connector of the wiring
harness to J2 of the control board.
17. Gently pull the liquid level probe out of the tank lid
and inspect for corrosion. Replace it if necessary.
18. Place the probe so that neither end is in contact
with any metal surface of the dispenser.
19. Check the voltage across the terminals of the inlet
solenoid valve with a voltmeter. Connect the dis-
penser to the power source. The indication must
be 120 volts ac for two wire 120 volt models, three
wire 120/208 volt models, three wire 120/240 volt
models afteradelayofapproximately10seconds.
20. Move the probe’s flat end to the dispenser hous-
ing. The indication must be 0.
21. Move the probe’s flat end away from the housing.
The indication must, again, be 120 volts ac for two
wire 120 volt models, three wire 120/208 volt
models, three wire 120/240 volt models after a
delay of approximately 5 seconds.
CONTROL BOARD - FMD-2 ONLY (CONT.)
6. Disconnect the four pin connector from J4 of the
control board.
7. Check the voltage across pins 1 & 4 of the four pin
connector on the wiring harness with a voltmeter.
Connect the dispenser to the power source. The
indication must be 120 volts ac for two wire 120
voltmodels, threewire120/208voltmodels, three
wire 120/240 volt models.
8. Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 9.
If voltage is not present as described, refer to the
wiring diagram and check the dispenser wiring har-
ness.
9. Reconnect the four pin connector of the wiring
harness to J4 of the control board.
22. Disconnect the dispenser from the power source.
10. Disconnect the ten pin connector from J2 of the
control board.
11. Carefully connect a piece of insulated jumper wire
to pin 10 (top right) of J2 on the control board.
Keep the other end of this wire away from any
metal surfaces of the dispenser.
If the voltage is present as described, re-install the
probe. The liquid level control circuitry is operating
properly.
If the voltage is not present as described, check the
pink probe wire and green tank wire for continuity.
12. Check the voltage across the terminals of the inlet
solenoid valve with a voltmeter. Connect the dis-
penser to the power source. The indication must
be 120 volts ac for two wire 120 volt models, three
wire 120/208 volt models, three wire 120/240 volt
models after a delay of approximately 10 seconds.
13. Touch the free end of the jumper wire to the
dispenser housing. The indication must be 0.
14. Move the jumper wire away from the housing. The
indicationmust, again, be120voltsacfortwowire
120 volt models, three wire 120/208 volt models,
three wire 120/240 volt models after a delay of
approximately 5 seconds.
Hopper Motor Control Circuitry:
1. Disconnect the dispenser from the power source.
2. Disconnect the six pin connector from J3 of the
control board.
3. Check the voltage across pins 5 & 6 of the six pin
connector on the wiring harness with a voltmeter.
Connect the dispenser to the power source. The
indication must be 24 volts ac.
4. Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 5.
If voltage is not present as described, refer to the
wiring diagram and check the dispenser wiring har-
ness.
15. Disconnect the dispenser from the power source
and remove the jumper wire.
5. Reconnect the six pin connector of the wiring
harness to J3 of the control board.
6. Check that the rinse/run switch is in the run
position.
If voltage is present as described, proceed to step 16.
If the voltage is not present as described, replace the
control circuit board.
29112 101598
21
DISPENSE SWITCH(S) - FMD-1 & FMD-2
SERVICE (cont.)
CONTROL BOARD - FMD-2 ONLY (CONT.)
7. Check the voltage across the red (+) terminal and
the black (-) terminal of the auger motor with a
voltmeter. Connect the dispenser to the power
source. Press and hold the appropriate dispense
switch. After a delay of about .6 seconds, the
indication must be between +4.0 and +24.5 volts
dc.
If the voltage is present as described, the hopper
motor control circuitry is operating properly.
If the voltage is not present as described, replace the
control circuit board.
NTIL CUP
U
N
Removal and Replacement:
OLD BUTTO
PUSH and
H
IS 2/3 FULL, THEN RELEASE
1. Disconnect the three plugs on the main wiring
harnessfromtheconnectorsonthecontrolboard.
2. Remove the four #6-32 keps nuts securing the
control board to the component bracket.
3. Remove control board and discard.
4. Installnewcontrolboardonthecomponentbracket
using four #6-32 keps nuts.
HEN CUFULL
ON
W
PLACE
CUP HERE
FMD-1
5. Reconnect the three plugs on the main harness to
the connectors on the control board.
J2 J3
PUSH and HOLD BUTTON
IS 2/3 FULL, THEN RE
J2
J3
PLACE
ON WHEN CUP IS 2/3 FULL
CUP HERE
J4
J1
FMD-2
P1614
J1
J4
FIG.14 DISPENSE SWITCH
P1640
Location:
FIG. 13 CONTROL BOARD CONNECTORS
The dispense switch(es) is (are) located on
the lower outside of the dispenser door.
29112 101598
22
SERVICE (cont.)
5. Disconnect the dispenser from the power source.
DISPENSE SWITCH(S) - FMD-1 & FMD-2 (cont.)
If voltage is present as described, proceed to #6.
If voltage is not present as described, refer to the wir-
ing diagram and check the dispenser wiring harness.
Test Procedure:
FMD-1
1. Disconnect the dispenser from the power source.
2. Open the dispenser door and remove the bottom
door cover.
3. Disconnect the wires from the door interconnect
wiring harness to the dispense switch.
4. Checkforvoltageacrosstheblackwireandthered
wire from the door interconnect wiring harness.
Connect the dispenser to the power supply. The
indication must be:
6. With a voltmeter, check the voltage across the
black/white (+) and orange (-) wires for the right
dispense switch, or blue/white (+) and orange (-)
fortheleftdispenseswitchfromthedoorintercon-
nect wiring harness. Connect the dispenser to the
power source. The indication must be +5 volts dc.
If voltage is present as described, proceed to #7.
If voltage is not present as described, refer to the
wiring diagram and check the dispenser wiring har-
ness.
a) 120 volts ac for two wire 120 volt models.
b) 120 volts ac for three wire 120/208 volt or 120/
240 volt models.
5. Disconnect the dispenser from the power source.
7. Check for continuity across the terminals (top
right to top left; bottom right to bottom left) of the
dispense switch with the switch in the “ON” posi-
tion. Continuity must not present when the switch
is in the “OFF” released position.
If voltage is present as described, proceed to #6.
If voltage is not present as described, refer to the wir-
ing diagram and check the dispenser wiring harness.
6. Check for continuity across the terminals with the
switch in the“ON” pressed position. Continuity
must not be present when the switch is in the
“OFF” released position.
If continuity is present as described, reconnect the
connector to the door interconnect wiring harness,
the switch is operating properly.
If continuity is not present as described, replace the
switch.
If continuity is present as described, reconnect the
connector to the door interconnect wiring harness,
the switch is operating properly.
If continuity is not present as described, replace the
switch.
Removal and Replacement
1. Open the dispenser door.
2. Remove the five #6-32 screws securing the bot-
tom door cover and remove cover.
3. Disconnect the wires on the dispense switch from
the door interconnect wiring harness.
4. Compress the clips inside the door on the dis-
pense switch and gently push the switch through
the opening
5. Push the new switch into the opening and spread
the clips to hold the switch in the door.
6. Reconnect the wires to the dispense switch from
the door interconnect wiring harness.
7. Reinstall the door bottom cover using five #6-32
screws.
FMD-2
1. Disconnect the dispenser from the power source.
2. Open the dispenser door and remove the bottom
door cover.
3. Disconnect the wires from the door interconnect
wiringharnesstothedispenseswitchtobetested.
4. Check for voltage across the black and red/white
wiresfortherightdispenseswitchortheblackand
redwiresfortheleftdispenseswitchfromthedoor
interconnect wiring harness. Connect the dis-
penser to the power supply. The indication must
be:
8. Refer to Fig. 15 when reconnecting wires.
a) 120 volts ac for two wire 120 volt models.
b) 120 volts ac for three wire 120/208 volt or 120/
240 volt models.
29112 101598
23
Location:
The fan is located inside the dispenser hous-
ing on the right rear of the dispenser base plate.
SERVICE (cont.)
DISPENSE SWITCH(S) - FMD-1 & FMD-2 (cont.)
BLK
RED
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the black and white wires from the fan
terminals.
3. Checkthevoltageacrosstheblackandwhitewires
on the main harness with a voltmeter. Connect the
dispenser to the power source. The indication
must be:
FMD-1
BLK
a) 120 volts ac for two wire 120 volts models.
b) 120 volts ac for three wire 120/208 volt or 120/
240 volt models.
RED/WHI
BLK
RED
If voltage is present as described, replace the fan
If voltage is not present as described, refer to wiring
diagram and check the dispenser wiring harness.
RIGHT
ORN
BLK/WHI
LEFT
ORN
BLU/WHI
Removal and Replacement:
FMD-2
1. Disconnect the vacuum hose from the fan.
2. Remove the two #8-32 locking screws securing
the fan to the dispenser housing base plate.
3. Disconnect the wires from the fan terminals and
discard the fan
P1449
FIG. 15 DISPENSE SWITCH TERMINALS
FAN - FMD-1 & FMD-2
4. Refer to Fig. 17 and connect the wires to the new
fan.
5. Install new fan through the rear access hole and
secure to the dispenser housing base plate using
two #8-32 locking screws.
6. Reconnect the vacuum hose to the fan.
BLK from Control Harness
WHI from Control Harness
P1507
P1665
FIG. 17 FAN TERMINALS
FIG. 16 FAN
29112 101598
24
4. Disconnect the dispenser from the power source.
SERVICE (cont.)
FROTHER AND WHIPPER MOTOR - FMD-1 (shown)
& FMD-2
If voltage is present as described, replace the motor.
If voltage is not present as described, refer to the wir-
ing diagrams and check the dispenser wiring harness.
13
8
1
2
4
11 12
3
10 9
7
6 5
P1619
FIG. 19 MIXING/WHIPPER CHAMBER
COMPONENTS
P1665
1. Steam Collector
8. Nut
FIG. 18 FROTHER AND WHIPPER MOTOR
2. Mixing Chamber
3. Dispense Tip
4. Whipper Chamber
5. O-Ring
9. Slinger
10. Motor Assy.
11. Fan
12. Vacuum Hose
13. Baffle
Location:
The frother(s) is (are) located behind the dis-
penser door, mounted on the front panel inside the
whipper chamber.
6. Frother
7. Receptacle w/Seal
The whipper motor(s) is (are) located on the
back side of the whipper motor mounting panel.
Removal, Cleaning and Replacement (Refer to Fig.
19):
1. Open the dispenser door and raise the top front
cover.
2. Lift the front edge of the each hopper assembly
over the tab on the hopper support panel and
slide each hopper assembly out the front of the
dispenser. Set aside for reassembly.
3. Remove the four #8-32 screws securing the hop-
per support panel to auger motor mounting
panel and the whipper motor mounting panel.
Set aside for reassembly.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Disconnect the red and white wires (FMD-1 &
FMD-2 left motor) or orange and white wires
(FMD-2 right motor) of the main harness from the
black leads of the motor.
3. Press and hold the dispense switch and check the
voltage across the disconnected harness wires
with a voltmeter. Connect the dispenser to the
power source. The reading must be:
a) 120 volts ac for two wire 120 volt models.
b) 120 volts ac for three wire 120/208 volt or 120/
240 volt models.
4. Disconnect vacuum hose (12) from fan baffle
(13).
29112 101598
25
23. Install whipper chamber (4) on the whipper cham-
ber receptacle (7) by twisting counterclockwise
untilthetabsonthewhipperchamber(4)lockwith
the tabs on the whipper chamber receptacle (7).
Be sure dispense port is pointing down.
24. Install dispense tip (3) into the bottom of the
whipper chamber (4).
25. Using two #4-40 screws secure the fan baffle to
the whipper motor mounting panel.
26. Install vacuum hose (12) on fan baffle (13).
27. Install hopper support panel using four #8-32
screws.
28. Slip the mixing chamber (2) onto the mixing
chamber water inlet tube far enough so the mixing
chamber (2) will seat inside the whipper chamber
(4).
29. Install the steam collector (1) onto the mixing
chamber (2) by pushing down and toward the
dispenser while twisting until the flange on the
steam collector lines-up with the slot in the front
panel.
30. Installhopperassemblyinthedispenserbysliding
hopper assembly on the hopper support panel
until the slot in the bottom rear of the hopper seats
against the shoulder screw in the hopper support
panel.
SERVICE (cont.)
FROTHER AND WHIPPER MOTOR - FMD-1
(shown) & FMD-2 (cont.)
5. Remove the steam collector (1) by pulling it for-
ward and at the same time twisting it clockwise.
6. Pull the mixing chamber (2) out of the whipper
chamber (4).
7. Remove the two #4-40 x .25" screws securing the
fan baffle (13) to the whipper motor mounting
panel and remove fan baffle. Set aside for reas-
sembly.
8. Remove dispense tip (3) and twist the whipper
chamber (4) clockwise and pull it off the whipper
chamber receptacle (7).
9. Pull the frother (6) off the motor shaft. Notice the
flat side on the shaft and the matching flat inside
the frother. It is important that these two flats are
lined up when reassembling.
10. Slip the O-ring (5) off the whipper chamber recep-
tacle (7).
11. Slide the receptacle w/seal off of the motor shaft.
12. Slide the slinger (9) off of the motor shaft.
13. Remove the two nuts (8) securing whipper cham-
ber receptacle (7) and whipper motor (10) to the
front panel.
NOTE: To remove the receptacle only rotate clockwise
until the receptacle clears the nuts (8) and slide off
of the motor shaft.
14. Disconnect the black leads on the motor (10) from
the main wiring harness.
15. Remove motor and discard.
BLK to Main Harness RED
BLK to Main Harness WHI
16. Install new motor (10) on rear of front panel and
secure with two nuts (8) and connect black leads
on the motor to the main wiring harness. Refer to
Fig. 20 when reconnecting wires
FMD-1
17. Slide slinger (9) onto the motor shaft flush against
the front panel.
18. Wash remaining components in a mild solution of
dish detergent using a bristle brush.
BLK to Main Harness ORN
BLK to Main Harness WHI
19. Rinse thoroughly and allow to dry before reinstall-
ing in the dispenser.
20. Slide whipper chamber receptacle w/seal (7) and
O-ring (5) on to the motor shaft.
21. Rotate the receptacle w/seal (7) counterclockwise
until it snaps into place on the motor mounting
nuts (8).
22. Pushfrother(6)ontothemotorshaft, makingsure
theflatinthefrother(6)linesupwiththeflatonthe
motor shaft.
BLK to Main Harness Red
BLK to Main Harness WHI
LEFT
RIGHT
FMD-2
FIG.20 WHIPPER MOTOR TERMINALS
P1221
29112 101598
26
terminal and the negative (black wire) terminal on
the auger motor with a voltmeter. With the rinse/
run switch in the run (lower) position press and
hold the dispense switch. Connect the dispenser
to the power supply. After a .6 second delay the
indication must be 4.0 to 24.5 volts dc.
SERVICE (cont.)
HOPPER DRIVE BOARD - FMD-1 ONLY
If voltage is present as described,the auger motor
drive is operating properly. If auger does not turn
replace the auger motor.
If voltage is not present as described, replace the
hopper drive board.
Removal and Replacement: (Refer to Fig. 2)
1. Remove hopper assy (17), and set aside for reas-
sembly.
2. Remove the four #8-32 screws securing the hop-
per support plate (12), remove plate and set aside
for reassembly.
3. Remove the four #8-32 screws, located inside the
dispener housing on the lower right front of the
auger motor mounting panel (21), securing auger
motor mounting bracket (18) and auger motor
(19) to the rear of the auger motor mounting panel
(21).
4. Disconnect the wires from the terminals on the
hopper drive board and disconnect the three pin
plug (J1) from the hopper drive board..
5. Remove auger motor mounting bracket (18), au-
ger motor (19), dust seal (20) and hopper drive
board as an assembly.
P1665
FIG. 21 HOPPER DRIVE BOARD
Location
The hopper drive board is located inside the
dispenser mounted on the auger motor mounting
bracket.
6. Remove the two #8-32 screws securing the hop-
per drive board to the auger motor mounting
bracket.
7. Remove the two spacers from the hopper drive
board and discard board.
8. Install spacers on new hopper drive board.
9. Install new hopper drive board to the auger motor
mounting bracket using two #8-32 screws..
10. Refer to Fig. 22 and reconnect the wires to the
hopper drive board terminals .
11. Connect three pin plug from the potentiometer to
the hopper drive board J1. Refer to Fig. 22.
12. Install auger motor mounting bracket with auger
motor and hopper drive board to the rear of the
auger motor mounting panel using four #8-32
screws.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the white/red wire and the white wire
from the hopper speed control board.
3. Check the voltage across the white/red wire and
the white wire with a voltmeter. With the rinse/run
switch in the run (lower) position, connect the
dispenser to the power supply. The indication
must be :
a) 120 volts ac for two wire 120 volt models.
b) 120 volts ac for three wire 120/208 volt or 120/
240 volt models.
4. Disconnect the dispenser from the power supply.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the wir-
ing diagram and check the dispenser wiring harness.
5. Check the voltage across the positive (red wire)
13. Install hopper support plate using four #8-32
screws.
14. Install hopper assy (17).
29112 101598
27
Test Procedure:
SERVICE (cont.)
1. Disconnect the dispenser from the power source.
2. Disconnect the wires from the switch terminals.
3. Check for continuity between the center terminal
and upper terminal with switch in the decrease
position (lower). Check for continuity between the
center terminal and the lower terminal with the
switch in the increase position (upper).
HOPPER DRIVE BOARD - FMD-1 ONLY (cont.)
RED from Hopper
Motor
J1 Connector for
J1
Three Pin Plug from
Potentiometer
If continuity is present as described, the switch is
operating properly.
If continuity is not present as described, replace the
switch.
BLK from
Hopper Motor
Removal and Replacement:
1. Open the dispenser door.
RED/WHI from
Main Harness
WHI from Main
2. Remove the facenut securing the increase/de-
crease switch to the whipper motor mounting
panel.
3. Remove switch with wires attached from the back
side of the whipper motor mounting panel.
4. Disconnect the wires from the switch and discard
the switch.
Harness
P1669
FIG. 22 HOPPER DRIVE BOARD TERMINALS
INCREASE/DECREASE SWITCH - FMD-2 ONLY
5. Refer to Fig. 24 when connecting the wires to the
new switch.
6. Install new switch with wires attached through the
hole in the whipper mounting panel and secure
with facenut.
RED/BLK from Control
Board J2-6
GRN from Control
Board J2-9
BRN/BLK from Control
Board J2-1
P1208
FIG. 24 INCREASE/DECREASE SWITCH
J2
J4
TERMINALS
J3
P1666
FIG. 23 INCREASE/DECREASE SWITCH
Location:
The increase/decrease switch is located on the
lower left front of the whipper motor mounting panel.
29112 101598
28
Removal and Replacement:
1. Open dispenser door (1).
SERVICE (cont.)
LAMP HOLDER - FMD-1 (shown) & FMD-2
2. Remove the four #8-32 screws securing lower
door panel (5) to the door (1) and remove cover.
3. Disconnect the door wiring harness from the door
interconnect wiring harness.
4. Remove two #8-32 screws securing the upper
door panel (4) to the door.
1
5. Remove the upper door cover (4), lamp (3), lamp
holders (2) and door wiring harness as an assem-
bly.
6. Disconnect the wires from the lamp holder to be
replaced from the door wiring harness.
7. Rotate lamp (3) 90° and remove from lamp hold-
ers (2).
3
4
5
2
8. Removethe#6-32screwsecuringthelampholder
(2) to be removed, remove lamp holder (2) and
discard.
9. Install new lamp holder (2) and secure with a #6-
32 screw.
6
10. Connect the wires on the new lamp holder to the
door wiring harness.
11. Install lamp (3) into lamp holders (2) and turn 90°
until the pins snap in place.
P1670
12. Install upper door panel (4), lamp (3), lamp hold-
ers (2) and door wiring harness as an assembly
using two #8-32 screws.
13. Reconnect the plug on the door wiring harness to
the connector on the door interconnect wiring
harness.
FIG. 25 LAMP HOLDERS
1. Door Assy
2. Lamp Holders
3. Lamp
4. Upper Panel
5. Lower Panel
6. Starter W/Socket
Location:
The lamp holders are located on the front of
the upper panel behind the display panel.
14. Install the door lower panel (5) using four #8-32
screws.
LAMP REPLACEMENT (Refer to Fig. 25)
1. Open dispenser door (1).
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Remove upper door panel (4) and disconnect the
door wiring harness from the leads on the lamp
holders.
3. Remove lamp from lamp holders.
4. Check for continuity on each lead of the lamp
holders.
2. Remove the four #8-32 screws securing lower
door panel (5) to the door (1) and remove cover.
3. Disconnect the door wiring harness from the door
interconnect wiring harness.
4. Remove two #8-32 screws securing the upper
door panel (4) to the door.
5. Remove the upper door cover (4), lamp (3), lamp
holders (2) and door wiring harness as an assem-
bly.
6. Rotate lamp (3) 90° and remove from lamp hold-
ers (2).
If continuity is present as described, lamp holders are
operating properly.
If continuity is not present as described replace the
lamp holder.
7. Install lamp (3) into lamp holders (2) and turn 90°
until the pins snap in place.
8. Install upper door panel (4), lamp (3), lamp hold-
ers (2) and door wiring harness as an assembly
using two #8-32 screws.
29112 101598
29
7. Insertnewstarter(6)intosocketandturn90°until
the pins snap in place.
8. Install new socket by compressing spring tabs on
the socket and pushing the socket up through the
hole in the lower door panel (5) and releasing
spring tabs.
SERVICE (cont.)
LAMP REPLACEMENT (Refer to Fig.24)(cont.)
9. Reconnect the plug on the door wiring harness to
the connector on the door interconnect wiring
harness.
10. Install the door lower panel (5) using four #8-32
screws.
9. Connect the sockets leads to the door wiring
harness.
10. Installdoorlowerpanel (5)withstarterandstarter
socket on door assy (1) using four #8-32 screws.
LAMP STARTER and SOCKET (Refer to Fig. 25)
Location:
The lamp starter (6) is located inside the door
assy (1) on the top of the door lower panel (5).
LEVEL CONTROL BOARD AND LEVEL PROBE -
FMD-1 ONLY
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the starter leads from the door wiring
harness.
3. Remove lamp starter from starter socket.
4. Check for continuity on each lead of the starter
socket.
If continuity is present as described the starter socket
is operating properly.
If continuity is not present as described replace the
starter socket.
5. Remove starter (6) from starter socket.
6. Check for continuity across the pins on the bottom
of the starter (6).
Ifcontinuityispresentasdescribed,replacethestarter.
If continuity is not present as described, starter is
operating properly.
Note:Ifcontinuitytestsarebothasdescribedandlamp
does not light, replace the starter.
P1665
FIG. 26 LEVEL CONTROL BOARD AND PROBE
Removal and Replacement (Refer to Fig.25):
1. Open dispenser door assy (1)
2. Remove the four #8-32 screws securing the door
lower panel (5) to the door assy (1).
3. Disconnecttheleadsonthestartersocketfromthe
door wiring harness.
Location:
The level control board is located behind the
lower access panel mounted on the right side of the
component bracket.
The Level probe is located on the left center
of the tank lid just in front of the overflow tube.
4. Remove lower door panel (5) and starter w/socket
(6) as assembly.
5. Compress the spring tabs on the socket and re-
move socket from the door bottom cover (5).
6. Rotate starter 90° and remove from the starter
socket.
29112 101598
30
SERVICE (cont.)
14. Check the voltage across terminals 1 & 3 with a
voltmeter. Connect the dispenser to the power
source.Theindicationmustbe120voltsacfortwo
wire 120 volt models, three wire 120/208 volt
models, three wire 120/240 volt models after a
delay of approximately 5 seconds.
15. Move the probe's flat end to the tank. The indica-
tion must be 0.
16. Move the probe's flat end away from the tank. The
indication should again be 120 volts ac for two
wire 120 volt models, three wire 120/208 volt
models, three wire 120/240 volt models after a
delay of approximately 5 seconds.
LEVEL CONTROL BOARD AND LEVEL PROBE -
FMD-1 ONLY (cont.)
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Removethevioletwirefromterminal1&pinkwire
from terminal 4 of the circuit board.
3. Check the voltage across terminals 2 & 3 with a
voltmeter. Connect the dispenser to the power
source. The indication must be 120 volts ac for
two wire 120 volt models, three wire 120/208 volt
models, three wire 120/240 volt models.
4. Disconnect the dispenser from the power source.
If voltage is present as described, reinstall the probe,
the level control board and level probe are operating
properly.
If voltage is not present as described, check the pink
probe wire for continuity.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the
wiringdiagramandcheckthedispenserwiringhaness.
5. Reconnect the violet wire to terminal 1.
6. Carefully connect a piece of insulated jumper wire
to terminal 4. Keep the other end of this wire away
from any metal surface of the dispenser.
7. Check the voltage across terminals 1 & 3 with a
voltmeter. Connect the dispenser to the power
source.Theindicationmustbe120voltsacfortwo
wire 120 volt models, three wire 120/208 volt
models, three wire 120/240 volt models after a
delay of approximately 5 seconds.
Removal and Replacement:
1. Remove all wires from the level control board.
2. Removetwo#8-32 kepsnutsholdinglevelcontrol
board to right side of the component bracket.
3. Remove level control board and spacers.
4. Install the new level control board and spacers to
the right side of the component bracket using two
#8-32 keps nuts.
5. Refer to Fig. 27 when reconnecting the wires.
8. Touch the free end of jumper wire to the compo-
nent bracket. The indication must be 0.
9. Move the jumper wire away from the component
bracket. The indication must again be 120 volts ac
for two wire 120 volt models, three wire 120/208
volt models , three wire 120/240 volt models after
a delay of approximately 5 seconds.
TI VIO to Inlet Solenoid Coil
T2 BLK to Main Harness
T3 WHI to Main Harness
T4 PNK to Probe
10. Disconnect the dispenser from the power source
and remove the jumper wire from terminal 4.
If voltage is present as described, the level control
board is operating properly, proceed to #11.
If voltage is not present as described, replace the level
control board.
P1671
11. Reconnect the pink wire to terminal 4.
12. Gently pull the probe out of the tank lid and inspect
for corrosion. Replace it if necessary.
FIG. 27 LEVEL BOARD TERMINALS
13. Place the probe so that neither end is in contact
with any metal surface of the dispenser.
29112 101598
31
SERVICE (cont.)
BLK to Tank Heater
LIMIT THERMOSTAT - FMD-1 (shown) & FMD-2
BLK to Control
Thermostat
P1800
FIG. 29 LIMIT THERMOSTAT TERMINALS
RINSE/RUN SWITCH - FMD-1
P1665
FIG. 28 LIMIT THERMOSTAT
Location:
The limit thermostat is located in the center of
the tank lid.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect both black wires from the limit ther-
mostat.
3. Check for continuity across the limit thermostat
terminals.
P1665
FIG. 30 RINSE/RUN SWITCH
If continuity is present as described, the limit thermo-
stat is operating properly.
Location:
If continuity is not present as described, replace the
limit thermostat.
The rinse/run switch is located on the lower
left side of the whipper motor mounting panel.
Removal and Replacement:
1. Remove all wires from the limit thermostat ter-
minals.
2. Carefully slide the limit thermostat out from un-
der the retaining clip and remove the limit ther-
mostat.
3. Carefully slide the new limit thermostat into the
retaining clip.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Check for continuity between center terminal and
the upper terminal with the switch in the “RUN”
lower position. Continuity must not be present
with the switch in the “RINSE” upper position.
If continuity is present as described, the switch is
operating properly.
4. Refer to Fig. 29 when reconnecting the wires.
If continuity is not present as described, replace the
switch.
Removal and Replacement:
1. Open the dispenser door.
29112 051200
32
Test Procedures:
SERVICE (cont.)
1. Disconnect the dispenser from the power source.
2. Check for continuity between the center left ter-
minal and left bottom terminal, also between the
center right terminal and the right bottom termi-
nal with the switch in the rinse position (upper).
Check for continuity across the center left termi-
nal and the top left terminal, also between center
right terminal and the top right terminal with the
switch in the run position (lower). Continuity must
not be present when the switch is in the center
position.
RINSE/RUN SWITCH - FMD-1 (CONT.)
2. Remove the facenut securing the run/rinse switch
to the dispenser front panel.
3. Remove switch with wires attached from the back
side of the front panel.
4. Disconnect the wires from the switch and dis-
card the switch.
5. Refer to Fig. 31 when connecting wires to the
new switch.
6. Install new switch with wires attached through
the hole in the front panel and secure with facenut.
If continuity is present as described, the switch is
operating properly.
If continuity is not present as described, replace the
switch.
RED from Main
Wiring Harness
Removal and Replacement:
1. Open the dispenser door.
2. Remove the facenut securing the run/rinse switch
to the whipper motor mounting panel.
3. Remove switch with wires attached from the back
side of the whipper motor mounting panel.
4. Disconnect the wires from the switch and dis-
card the switch.
WHI/RED to
Main Harness
5. Refer to Fig. 33 when connecting the wires to
the new switch.
P1456
FIG. 31 RINSE/RUN SWITCH TERMINALS
6. Install new switch with wires attached through
the hole in the whipper motor mounting panel
and secure with facenut.
RINSE/RUN SWITCH - FMD-2
GRY to Control
Board J2-2
WHI/BRN to
Main Harness
GRN to Control
Board J2-9
BLK from
Main Harness
J2
J4
J3
WHI/BRN to
Main Harness
YEL to Control
Board J2-3
P1644
P1666
FIG. 32 RINSE/RUN SWITCH
FIG. 33 RINSE/RUN SWITCH TERMINALS
Location:
The rinse/run switch is located on the lower
center of the whipper motor mounting panel.
29112 101598
33
6. Check the solenoid valve for coil action. Connect
the dispenser to the power source. With the cold
jumperpluginstalledpresstheleftdispenseswitch
and listen carefully in the vicinity of the solenoid
valvefora“clicking”soundasthemagnetattracts.
7. Disconnect the dispenser from the power source.
SERVICE (cont.)
SOLENOID VALVE (COLD WATER
OPTIONAL)(FMD-2 ONLY)
If the sound is heard as described and water will not
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the
solenoid valve may require inspection for wear, and
removal of waterborne particles.
J1
J2
J4
J3
If the sound is not heard as described, replace the
solenoid valve.
Removal and Replacement:
P1666
1. Loosen the two screws securing the component
bracket to the dispenser base. Lift the component
bracket off of the base and move to the right.
2. Remove the white and blue from the solenoid
valve.
3. Turn-off the water supply to the dispenser.
4. Disconnect the water lines to and from the sole-
noid valve.
5. Loosen the two #8-32 screws and washers secur-
ing the solenoid mounting bracket to the base.
Remove solenoid bracket and solenoid valve as an
assembly.
6. Remove the two #10-32 screws and lockwashers
securingthesolenoidvalvetothesolenoidbracket.
7. Using two #10-32 screws and lockwashers install
new solenoidvalveonsolenoidmountingbracket.
8. Install the solenoid valve and bracket on the dis-
penser base and tighten the two #8-32 screws.
9. Securely fasten the water lines to and from the
solenoid valve.
FIG. 34 COLD WATER SOLENOID VALVE
Location:
The cold water solenoid valve is located on
the left side of the dispenser base just behind the com-
ponent bracket.
Test Procedures:
1. Disconnectthedispenserfromthepowersource.
2. Disconnect the white and blue wires from the
solenoid valve. With the cold jumper plug in-
stalled press the left dispense switch on front of
the door.
3. Checkthevoltageacrossthewhiteandbluewires
with a voltmeter. Connect the dispenser to the
power source. The indication must be 120 volts
ac for two wire 120 volt models, three wire 120/
208 and 120/240 volt models.
4. Disconnectthedispenser fromthepowersource.
10. Refer to Fig. 35 when reconnecting the wires.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to wiring
diagram and check dispenser wiring harness.
BLU to Main Harness
WHI to Main Wiring
Harness
5. Check for continuity across the solenoid valve
coil terminals.
If continuity is present as described, reconnect the
white and blue wires to the solenoid.
If continuity is not present as described, replace the
solenoid valve.
P1215
FIG. 35 COLD WATER SOLENOID TERMINALS
29112 101598
34
Test Procedures:
SERVICE (cont.)
1. Disconnectthedispenserfromthepowersource.
2. For FMD-1 disconnect the red and white wires
from the solenoid valve. For FMD-2 disconnect
orange and white wires on the right solenoid or
the tan and white wires on the left solenoid. With
the “RINSE/RUN” switch in the "RINSE" upper
position press the dispense switch on front of
the door.
SOLENOID VALVE (DISPENSE) - FMD-1 & FMD-2
3. Check the voltage across the red and white,
orange and white or tan and white wires with a
voltmeter. Connect the dispenser to the power
source. The indication must be 120 volts ac for
twowire120voltmodels,threewire120/208and
120/240 volt models.
4. Disconnectthedispenserfromthepowersource.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to wiring
diagram and check dispenser wiring harness.
5. Check for continuity across the solenoid valve
coil terminals.
FMD-1
P1665
If continuity is present as described, reconnect the
wires to the solenoid (see Fig. 37), proceed to #6
If continuity is not present as described, replace the
solenoid valve.
6. Check the solenoid valve for coil action. Connect
the dispenser to the power source. With "RINSE/
RUN” switch in the "RINSE" upper position press
the dispense switch and listen carefully in the
vicinity of the solenoid valve for a "clicking" sound
as the coil magnet attracts.
7. Disconnect the dispenser from the power source.
If the sound is heard as described and water will not
pass through the solenoid valve, there may be a block-
age in the water outlet before the solenoid valve or,
the solenoid valve may require inspection for wear,
and removal of waterborne particles.
FMD-2
P1666
If the sound is not heard as described, replace the
solenoid valve.
FIG. 36 DISPENSE SOLENOID VALVE
Location:
Removal and Replacement:
The dispense solenoid is located on the upper
left center of the tank.
1. Open dispenser door and remove the hopper(s)
2. Remove the two #8-32 screws securing the hop-
per panel to the auger motor mounting panel and
two #8-32 screws to the whipper mounting panel.
29112 101598
35
SOLENOID VALVE (INLET) - FMD-1 & FMD-2
SERVICE (cont.)
SOLENOID VALVE (DISPENSE) - FMD-1 & FMD-2
(cont.)
Remove panel and set aside.
3. Remove the two #8-32 securing the auger motor
mounting panel to the dispenser housing and the
two rear #8-32 screws from the side panels.
4. Tilt auger motor mounting panel forward allowing
access to the dispense valve(s).
5. Remove the wires from the solenoid valve.
6. Turn-off the water supply to the dispenser.
7. Drain enough water from the tank so the water
level is below the dispense valve mounting hole.
8. Disconnect the water line from the solenoid valve.
9. Remove the #10-32 screw securing the solenoid
valve to side of the tank. Remove solenoid valve.
10. Usingthe #10-32screwinstallnewsolenoidvalve
on side of the tank
11. Push the water line onto the tube on bottom of
solenoid valve.
12. Refer to Fig. 37 and reconnect the wires.
13. Reassemble auger and hopper components.
P1665
FIG. 38 INLET SOLENOID VALVE
Location:
The inlet solenoid is located on the lower right
side of the rear panel.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the white and violet wires from the
solenoid valve.
3. Checkthevoltageacrossthewhiteandvioletwires
with a voltmeter. Connect the dispenser to the
power source. The indication must be 120 volts ac
for two wire 120 volt models, three wire 120/208
and 120/240 volt models.
RED to Main Harness
WHI to Main Harness
FMD-1
4. Disconnect the dispenser from the power source,
ORN to Main
Harness
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to the
wiring diagram and check dispenser wiring harness.
WHI to Main
Harness
5. Check for continuity across the solenoid valve coil
terminals.
RIGHT
If continuity is present as described, reconnect the
white and violet wires to the solenoid.
If continuity is not present as described, replace the
solenoid valve.
TAN to Main Harness
LEFT
WHI to Main Harness
FMD-2
FIG. 37 DISPENSE SOLENOID VALVE
P1672
6. Check the solenoid valve for coil action. Connect
thedispensertothepowersource. Listencarefully
in the vicinity of the solenoid valve for a "clicking"
sound as the coil magnet attracts.
TERMINALS
29112 011906
36
TANK HEATER - FMD-1 (shown) & FMD-2
SERVICE (cont.)
SOLENOID VALVE (INLET) - FMD-1 & FMD-2
(cont.)
7. Disconnect the dispenser from the power source.
If the sound is heard as described and water will not
pass through the solenoid valve, there may be a
blockage in the water line before the solenoid valve or,
the solenoid valve may require inspection for wear,
and removal of waterborne particles.
If the sound is not heard as described, replace the
solenoid valve.
Removal and Replacement:
1. Remove the white and violet wires from the sole-
noid valve.
2. Turn-off the water supply to the dispenser.
3. Disconnect the water lines to and from the sole-
noid valve.
4. Remove the two #8-32 screws securing the sole-
noid to the rear of the dispenser housing. Remove
solenoid.
5. Remove the two #8-32 U-Type fasteners from the
solenoid bracket.
6. Installthetwo#8-32U-Typefastenersandthetwo
#8-32 screws on the new solenoid.
7. Install new solenoid on rear of dispenser housing
and tighten the two screws
8. Securely fasten the water lines to and from the
solenoid valve.
P1665
FIG. 40 TANK HEATER
Location:
The tank heater is located inside the tank and
secured to the tank lid.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Checkthevoltageacrosstheblackandwhitewires
120voltmodelsorblackandredwiresfor120/208
volt modelsor120/240voltmodelswithavoltme-
ter. Connect the dispenser to the power source.
The indication must be:
a) 120 volts ac for two wire 120 volt models;
b) 208 volts ac for three wire 120/208 volt models.
c) 240 volts ac for three wire 120/240 volt models.
3. Disconnect the dispenser from the power source.
9.Refer to Fig. 39 and reconnect the wires.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the
dispenser wiring diagram and check the wiring har-
ness.
4. Disconnect the black wire and the white or red
wire from the tank heater terminals.
5. Check for continuity across the tank heater termi-
nals.
WHI from Main Harness
VIO from Main Harness
If continuity is present as described, reconnect the
wires, the tank heater is operating properly.
If continuity is not present as described, replace the
tank heater.
P1217
FIG. 39 INLET SOLENOID VALVE TERMINALS
29112 101598
37
TANK HEATER SWITCH - FMD-1 (shown) & FMD-2
SERVICE (cont.)
TANK HEATER - FMD-1 (shown) & FMD-2 (cont.)
NOTE - If the tank heater remains unable to heat,
remove and inspect heater for cracks in the sheath.
Removal and Replacement:
1. Disconnect the dispenser from the power source.
2. Disconnect the water supply tube on the tank lid.
3. Disconnect the black wires on the limit thermstat.
4. Disconnecttheblackwireandthewhiteorredwire
from the tank heater terminals.
5. Disconnect the pink wire from the liquid level
probe and the green wire from the tank.
6. Remove the thermostat capillary bulb by firmly
pulling-up on the capillary at the tank lid. This will
disengage the grommet from the tank lid.
7. Remove the ten #8-32 nuts securing the tank lid to
the tank.
P1665
FIG. 42 TANK HEATER SWITCH
Location:
8. Remove tank lid with limit thermostat, liquid level
probe and tank heater as an assembly.
9. Remove the two hex nuts securing the tank heater
to the tank lid. Remove tank heater with gaskets
and discard.
10. Install new tank heater with gaskets on the tank lid
and secure with two hex nuts.
11. Install tank lid with limit thermostat, liquid level
probe and tank heater on the tank and secure with
ten #8-32 hex nuts.
12. Connect water inlet line to the tank lid.
13. Reconnect the black wires to limit thermostat, the
pink wire to the liquid level probe and the green
wire to the tank. Refer to the limit thermostat and
the liquid level board and probe sections in this
manual when reconnecting wires.
The tank heater switch located inside the dis-
penser on the upper right of the front panel.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Disconnect the black wires from the main wiring
harness.
3. With the switch in the “ON” lower position check
for continuity between the center and the upper
terminal. With the switch in the “OFF” upper posi-
tion no continuity should be present between
center and upper terminals.
If continuity is present as described, the tank heater
“ON/OFF” switch is operating properly.
If continuity is not present as described, replace the
switch.
14. RefertoFig.41 whenreconnectingthewirestothe
tank heater.
Removal and Replacement:
1. Remove the switch mounting nut on the front of
the front panel.
BLK to Limit
Thermostat
WHI or RED to
Main Harness
2. Remove switch with wires attached from the rear
of the front panel.
3. Remove the wires from the switch terminals and
discard switch.
4. Connect the wires to the new switch, refer to Fig.
43.
5. Push new switch through hole in the front panel
and secure with facenut.
P1218
FIG. 41 TANK HEATER TERMINALS
29112 101598
38
SERVICE (cont.)
If voltage is present as described reconnect the plug
and the connector and proceed to #5.
If voltage is not present as described, refer to the
wiring diagrams and check the main wiring harness.
BLK to Main
Harnesss
5. Check the voltage between J1-1 and J1-2 on the
eight pin connector at the control board. Connect
the dispenser to the power source. The indication
must be 24 volts ac.
BLK from Main
Harness
If voltage is present as described the transformer is
operating properly.
If voltage is not present as described, replace the
transformer.
FIG. 43 TANK HEATER SWITCH TERMINALSP1219
TRANSFORMER - FMD-2 ONLY
Removal and Replacement:
1. Loosen the two #8-32 screws securing the com-
ponent bracket to the dispenser housing base.
2. Pull component bracket out the front of the dis-
penser far enough so the transformer connector
can be disconnected from the main wiring har-
ness.
3 Disconnect the transformer four pin connector
from the four pin plug on the main wiring harness.
4. Remove the two #6-32 keps nuts securing the
transformer to the rear of the component bracket.
5. Remove and discard the transformer.
6. Install new transformer on the rear of the compo-
nent bracket and secure with two #6-32 keps nuts.
7. Connectthefourpinconnectoronthetransformer
to four pin plug on the main wiring harness.
8. Place the component bracket into position and
tighten the two #8-32 screws.
2
J
4
J
3
J
P1666
FIG. 44 TRANSFORMER
Location:
The transformer is located behind the lower
front access cover, mounted on the right rear side
of the component bracket.
WHI/GRN - T7
Test Procedure:
12
WHI/BLK - T12
11
9
8
7
1. Disconnect the dispenser from the power source.
2. Disconnect the four pin plug from the main har-
ness from the four pin connector on the trans-
former.
3 Check the voltage across black wire pin 1 and the
whitewirepin2ontheplugfromthemainharness.
Connect the dispenser to power source. The indi-
cation must be:
WHI - 120V T2, 240V T6
BLK - TI
FIG. 45 TRANSFORMER TERMINALS
a. 120 volts ac for two wire 120 volt models.
b.120voltsforthreewire120/208voltmodelsand
three wire 120/240 volt models.
P1703
4. Disconnect the dispenser from the power source.
29112 101598
39
SCHEMATIC WIRING DIAGRAM FMD-1
GRN
L2
N
L1
CONTROL
THERMOSTAT
LIMIT
THERMOSTAT
HEATER
SWITCH
RED-16 (3-WIRE MODELS)
WHI-16 (2-WIRE MODELS)
TANK HEATER
BLK-16
BLK-16
BLK-16
BLK-16
WHI
BLK
BLK
FAN
TANK INLET
VIO
HOPPER SPEED ADJUST
WHI
WHI
SOL
1
2
3
4
LIQUID
LEVEL
BOARD
BLK
PNK
GRN
RUN/RINSE
SWITCH
J1
PROBE
WHI
WHI/RED
RED
RED
RED
1 2
3
HOPPER
DRIVE
PCB
GRN
HOPPER
M
DISPENSE
WHIPPER
M
WHI
RED
WHI
RED
BLK
SOL
WHI
RED
BLK
BLK
FLUORESCENT
LAMP
BLU
BLK
BLK
DISPENSE SWITCH
BALLAST
BLK
RED
CHASSIS
GRN
1
4
1
DOOR
BLU
BLU
WHI
BLK
RED
RED
BLK
BLK
120 VOLTS A C - 2 WIRE
120/208-240 VOLTS AC - 3WIRE
SINGLE PHASE
STARTER
BLK
WHI
29112 101598
40
SCHEMATIC WIRING DIAGRAM FMD-2
GRN
L1
L2
N
TANK HEATER
SWITCH
CONTROL
THERMOSTAT
LIMIT
THERMOSTAT
RED-16 (3-WIRE MODELS)
WHI-16 (2-WIRE MODELS)
TANK HEATER
BLK-16
BLK-16
BLK-16
BLK-16
BLK-16
BLK
BLK
BLK
FAN
WHI
WHI
WHI WHI
WHI
VIO
WHI
J4-1
J4-4
TANK INLET
VIO
WHI
BLK
SOL
WHI/BLK
WHI/GRN
WHI
WHI/BLK
WHI/GRN
WHI
120V : 24V AC
TRANSFORMER
BLK
BLK
C
O
N
T
R
O
L
WHI/BLK
WHI/GRN
WHI
J3-1
WHI/ORN
WHI/RED
GRN
WHI/GRN
WHI/BLK
BLK
GRN
P
.
J3-6
J2-1
C
.
BRN/BLK
GRY
YEL
B
O
A
R
D
WHI
WHI
WHI/ORN
WHI/YEL
RED/BLK
WHI/RED
GRN
BLK
J2-5
RINSE/PROGRAM/
RUN SWITCH
GRN
GRN
PNK
GRY
RUN
GRN
BLK
J2-10
PGM
FLUORESCENT
INCREASE/
DECREASE
SWITCH
I
D
E
BLK BLK
LAMP
YEL
N
C
RINSE
RUN
C
GRN
BALLAST
WHI/BRN
PGM
RINSE
BRN/BLK
RED/BLK
WHI/BRN
PROBE
GRN
RIGHT HOPPER
RIGHT DISPENSE
RIGHT WHIPPER
WHI/ORN
ORN
ORN
RED
BLK
WHI
WHI
GRN
GRN
M
M
SOL
LEFT DISPENSE
LEFT WHIPPER
LEFT HOPPER
WHI/RED
TAN
RED
WHI
RED
WHI
BLK
M
M
SOL
ORN
COLD DRINK OPTION (LEFT ONLY)
1
4
RED
RED
TAN
WHI
BLU
BLU
WHI
RED
RED
RED
SOL
JUMPER PLUG MUST BE
USED WHEN COLD
DRINK FEATURE NOT
INSTALLED
WHI
CHASSIS
120 VOLTS AC - 2 WIRE
120/208-240 VOLTS AC - 3 WIRE
SINGLE PHASE, 60 HZ
1
4
G
R
N
1
4
GRY
1
1
1
GRN/BLK
WHI/BLK
DOOR
PNK
"RINSE" L.E.D.
WHI
BLU
BLU
BLU
WHI
RED
BLK
BLK
1
STARTER
BLK
ORN
BLK
ORN
BLK
BLK/WHI
RED/WHI
BLU/WHI
RED
RED
BLK
WHI
LEFT DISPENSE SWITCH
RIGHT DISPENSE SWITCH
29112 101598
41
|