Bunn Autopod Brewer 411701 User Manual

PROGRAMMING MANUAL  
BUNN-O-MATIC CORPORATION  
POST OFFICE BOX 3227  
SPRINGFIELD, ILLINOIS 62708-3227  
PHONE: (217) 529-6601 FAX: (217) 529-6644  
41170.0000B 05/12 ©2010 Bunn-O-Matic Corporation  
CONTENTS  
LOCKOUT SWITCH .............................................................................................4  
PROGRAMMING SWITCHES...............................................................................5  
PROGRAMMING.................................................................................................6  
411701 061308  
Page 3  
ADJUSTMENTS & PROGRAMMING  
PROGRAMMING THE BREWER  
The programming of the brewer is divided into two levels. Brewing adjustments are in Level 1. Service func-  
tions are accessed in Level 2.  
The following function screens are in order of appearance. Each screen will have instructions on how to  
access, and the procedures to program the various functions of the brewer.  
IMPORTANT PROGRAMMING NOTES  
- READ CAREFULLY -  
To exit the programming mode at any time, press and hold "Hidden" switch located on the front panel. The  
display will return to the MAIN SCREEN.  
If none of the programming switches are pressed within one minute during programming, the display will  
return to the MAIN SCREEN.  
Always remember to place an empty cup under the sprayhead when operating the brewer during the set-up  
of PULSE BREW, CALIBRATE FLOW and testing the brew valve in SERVICE TOOLS/TEST OUTPUTS.  
PROGRAMMING LOCKOUT SWITCH  
(Mounted on main control board)  
This switch can be set to prevent access to  
the programming settings of the brewer.  
Once all the correct brew settings are pro-  
grammed, the operator can set the switch  
to the "ON" position to prohibit anyone from  
changing the settings. With the switch in the  
"ON" position, the programming menus can  
stillbeaccessedtoviewthecurrentsettings.  
However, no changes will be saved.  
Disconnect brewer from power source  
before removing any panel!  
411701 061308  
Page 4  
PROGRAM FUNCTIONS  
MAIN SCREEN  
WER  
toPOD BRE  
u
A
HIDDEN SWITCH  
Press until display reads  
"BREW LOCKOUT"  
Press/hold to exit program  
SMALL BREW  
Step backwards through screens  
BREW LOCKOUT:  
NEXT  
BREW LOCKOUT ?  
DONE  
Prevents brewing if the water temperature is less than  
NO  
YES  
the "SET READY" temperature. To access this function  
screen press and hold the hidden switch. Release when  
the display reads: "BREW LOCKOUT".  
TheYESorNOshouldbeashing. SelectYEStoprevent  
brewingifthewatertemperatureisbelowthesetREADY  
temperature. Select NO to permit brewing at any water  
temperature.  
Whennished,pressandreleaseDONE.Thiswillstepto  
the next function screen. To return to the MAIN SCREEN  
at any time, press and hold the hidden switch.  
Press here  
for YES  
Press here  
for NO  
B
A
Press here  
for DONE  
411701 061308  
Page 5  
PROGRAM FUNCTIONS  
BREW TYPE (A/B) (Tea/Coffee)  
Tea setting provides half the "purge" pressure as coffee at the end of brew  
cycle.  
BREW TYPE A  
TEA DONE COFFEE  
BREW OZ. (A/B) (1-16)  
Adjust brew volume.  
BREW OZ A: 8.0  
(-)  
DONE  
(+)  
BREW METER (A/B) (1-5)  
Simplified pulse brew adjustment. 1=Preinfusion. 2-5=pulse brew,  
2 being the shortest pulse brew cycle, 5 the longest pulse brew cycle.  
BREW METER A: 2  
+
-
ENTER SERVICE #  
ENTER SERVICE #?  
Program service phone number to be displayed anytime there is a fault mes-  
sage.  
NO  
YES  
ENTER PASSWORD  
ENTER PASSWORD  
User must enter a 3 digit number to access remainder of adjustments. If no  
number has been pre-programmed (0 0 0), then access is allowed.  
0
0
0
SET PASSWORD (001-999)  
Program any three digit number as a password.  
SET PASSWORD  
0
0
0
SET LANGUAGE  
Choose between English or Spanish.  
SET LANGUAGE ?  
NO  
YES  
UNITS  
UNITS  
Choose between English (Oz, F°) or metric (Ml, C°)  
METRIC DONE ENG  
SET TEMP  
SET TEMP:  
(-) DONE  
200°  
(+)  
Adjust tank temperature 185 to 205° F (85 to 96° C)  
SET READY  
SET READY: 195°  
Sets the minimum temperature allowable to start a brew cycle, if "BrewLockout"  
is enabled. Range: (2° to 20° F) or (2° to 10° C) below the set temperature.  
(-)  
DONE  
(+)  
ENTER ASSET #  
ENTER ASSET # ?  
NO  
This function allows the you to enter in an optional 4 digit number. This can be  
useful for tracking the usage of an individual machine within a group.  
YES  
SET PULSE BREW (A/B)  
Individuallyadjuston/offtimes. 1stontime:OFF-.5-24.0;OFFtime:OFF-.5-24.0;  
Last on time: Preinfusion-.5-24.0 This will overwrite "BREW METER"  
SetPulseBrew A/B ?  
NO DONE YES  
AIR TIME (A/B) (1-25 seconds)  
Time the brew tank is purged at the end of each brew cycle.  
AIR TIME A/B: 15.0  
(-) DONE (+)  
CONTINUED  
411701 061308  
Page 6  
PROGRAM FUNCTIONS  
DRIP TIME (A/B) (OFF/1-50 seconds)  
Time between brew cycle and pod ejection.  
DRIP TIME A/B: 15  
(-) DONE (+)  
BREWS TO EMPTY (OFF/15-25)  
Set number of used pods in bin to turn on "EMPTY BIN" message.  
BREWS TO EMPTY  
(-)  
25  
(+)  
ENABLE ENERGY SAVER  
Choose to have the tank heaters turn off, or reduce the tank temp to (140° F)  
or (60° C) once the "SET IDLE TIME" has expired. .5-50.0 hrs.  
Enabl EnergySavr  
NO  
DONE  
YES  
AIR PUMP POWER (1 Weakest - 4 Strongest )  
Adjust air pressure for end of brew cycle purge. Due to pod variations, reduce  
as needed if splattering occurs.  
AIR PUMP POWER 4  
(-)  
DONE  
(+)  
BREW COUNTS  
BREW COUNT ##  
YES  
Retains the total number of brew cycles completed, not reset-able.  
NO  
BREW COUNTS  
Retains the total number of brew cycles completed, reset-able.  
BREW COUNT ##  
RESET NEXT  
CALIBRATE FLOW  
CALIBRATE FLOW ?  
NO YES  
Thisfunctionallowsyoutoentertheactualowrateofthesprayheadbydispens-  
ing for one minute. The volume is then entered in ounces per minute. (Oz/M)  
Place a 10 ounce or larger measuring cup under sprayhead and press one of  
the brew switches.  
PRESS  
BREW TO START  
Afterdispensenishes,readnumberofouncesandenterthatamountintobrewer  
using the +/- switches, then press "DONE" to set the volume into memory.  
ENTER OZ 10.0  
(-)  
DONE  
(+)  
SERVICE TOOLS allows testing of load components and switches.  
It should only be used by trained technicians.  
SERVICE TOOLS ?  
NO  
YES  
TEST OUTPUTS allows testing of load components by manually turning them  
TEST OUTPUTS 
?  
ON/OFF.  
---PLACE A 10 OUNCE CUP UNDER DISPENSE AREA---  
NO  
YES  
WARNING: HOT WATER WILL DISPENSE DURING SOME TEST MODES!  
INDEX MOTOR DUMP runs the pod holder back to the pod ejection position.  
LOAD moves it out to the door open position. "B " indicates the assembly is  
in home postion.  
INDEX B  
MO
TOR  
DUMP NEXT LOAD  
EXTERNAL RELAY Main control board outputs 12vdc to activate external relay.  
The N.O. contact then closes to provide line voltage to the heater in HOT WATER  
TANK.  
EXTERN
AL R
ELAY  
ON NEXT OFF  
CONTINUED  
411701 061308  
Page 7  
WATER INLET  
WaterInIet  
#
Activates the water inlet valve for the brew tank, and flow meter count.  
ON NEXT OFF  
AIR PUMP  
AIR PUMP  
Activates the air pump motor for the brew tank.  
ON NEXT OFF  
HOT WATER  
HOT WATER  
Activates the water inlet solenoid for the hot water tank.  
ON NEXT OFF  
VENT VALVE  
Activates the vent solenoid for the hot water tank.  
VENT VALVE  
ON NEXT OFF  
WATER PUMP  
N/A  
WATER PUMP  
ON NEXT OFF  
HOT WATER AIR PUMP  
Activates the air pump motor for the hot water tank.  
HotWaterAir PUMP  
ON NEXT OFF  
TANK HEATER  
TANK HEATER  
Activates the triac/relay on the main control board for the brew tank heater.  
ON NEXT OFF  
TEST SWITCHES allows testing of the membrane switches.  
TEST S
WITC
HES ?  
NO  
YES  
Press the hidden program switch to go back to previous screen. Pressing any  
other membrane switch will give corresponding readout for that switch.  
PROGRA
M SW
IT
CH  
TO EXIT  
FACTORY BLOWOUT  
Used for tank draining.  
FACTORY BLOWOUT  
NO  
YES  
FACTORY DEFAULTS  
Reset all brew settings, calibrations back to factory presets.  
Requires following "INITIAL SETUP" procedure.  
FACTORY DEFAULTS  
NO YES  
EXIT PROGRAM MODE TO MAIN SCREEN  
Model:  
Software version:  
AutoPOD BREWER  
VERSION xx.xx  
411701 061308  
Page 8  
411701 061308  
Page 9  

NAD 501 User Manual
Magnavox AZ 2805 User Manual
ID Tech 60 User Manual
GE General Electric Computer Accessories 2300 V User Manual
Fujitsu Computer Drive MHV2060AS User Manual
Dualit Espression Supremma CA4815 User Manual
Clarion DXZ375MP User Manual
Braun KF590E User Manual
Black & Decker BCM1410BCUC User Manual
Aroma ACU 040 User Manual