Bunn 37614 041410 User Manual

DUAL / GPR-DBC  
WITH SMART FUNNEL®  
S
M
A
U
R
T
F
N
N
E
L
S
M
A
U
R
T
F
N
N
E
L
T
O
H
E
R
A
S
E
C
A
F
R
U
S
D
N
A
S
R
E
M
R
A
W
:
N
O
I
T
U
A
C
INSTALLATION & OPERATING GUIDE  
BUNN-O-MATIC CORPORATION  
POST OFFICE BOX 3227  
SPRINGFIELD, ILLINOIS 62708-3227  
PHONE: (217) 529-6601 FAX: (217) 529-6644  
To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit  
the latest catalog and manual updates. Contact Bunn-O-Matic Corporation at 1-800-286-6070 to obtain  
a paper copy of the required Illustrated Parts Catalog mailed via U.S. Postal Service.  
37614.0000E 04/10 ©2004 Bunn-O-Matic Corporation  
USER NOTICES  
The notices on this brewer should be kept in good condition. Replace unreadable or damaged labels.  
WARNING  
• DO NOT OVERLOAD CIRCUIT.  
ALWAYS ELECTRICALLY GROUND  
THE CHASSIS.  
• DO NOT DEFORM PLUG OR CORD.  
• FOLLOW NATIONAL AND LOCAL  
ELECTRICAL CODES.  
• KEEP COMBUSTIBLES AWAY.  
FAILURE TO COMPLY RISKS EQUIPMENT  
DAMAGE, FIRE OR SHOCK HAZARD.  
READ THE ENTIRE  
OPERATING MANUAL BEFORE  
USING THIS PRODUCT  
00986.0000F 10/07 ©1994 Bunn-O-Matic Corporation  
00986.0000  
00658.0000  
As directed in the International Plumbing Code of the  
International Code Council and the Food Code  
Manual of the Food and Drug Administration (FDA),  
this equipment must be installed with adequate  
backflow prevention to comply with federal, state  
and local codes. For models installed outside the  
U.S.A., you must comply with the applicable Plumb-  
ing /Sanitation Code for your area.  
00656.0001  
37881.0000  
MAIN ON/OFF  
SWITCH  
03408.0004  
39803.0000  
03409.0004  
20201.5600  
12364.0000  
37614 042210  
Page 3  
ELECTRICAL REQUIREMENTS  
WARNING - The brewer must be disconnected from the power source until specified in Initial Set-Up.  
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.  
Requirements for brewers without an attached cord set are as follows:  
L2 WHITE/VIOLET  
120 V.A.C.  
WHITE  
208 OR 240 V A.C.  
NEUTRAL  
120 V.A.C.  
L1 BLACK  
P1841  
120/208 & 120/240 volt ac models  
Note: This electrical service consists  
of 3 current carrying conductors  
(Neutral, L1 and L2) and a separate  
conductor for earth ground.  
ELECTRICAL HOOK-UP  
CAUTION: Improper electrical installation will damage electronic components.  
1. An electrician must provide electrical service as specified.  
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.  
3. Remove the front panel beneath the sprayheads.  
4. Feed the cord through the strain relief and connect it to the terminal block.  
5. Connect the brewer to the power source and verify the voltage at the terminal block before proceeding.  
Replace the front panel.  
6. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing  
has been hooked up, the brewer is ready for Initial Set-Up.  
37614 062107  
Page 4  
PLUMBING REQUIREMENTS  
This brewer must be connected to a cold water system with operating pressure between 20 and 90 psi (138  
and 620 kPa) from a 12" or larger supply line. A shut-off valve should be installed in the line before the brewer.  
Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa).  
The water inlet fitting is 38" flare.  
NOTE: Bunn-O-Matic recommends 14" copper tubing for installations of less than 25 feet and 38" for more than 25  
feet from the 12" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer  
to clean the counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The  
size and shape of the hole made in the supply line by this type of device may restrict water flow.  
AsdirectedintheInternationalPlumbingCodeoftheInternationalCodeCouncilandtheFoodCodeManual  
of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow  
prevention to comply with federal, state and local codes. For models installed outside the U.S.A., you  
must comply with the applicable Plumbing /Sanitation Code for your area.  
PLUMBING HOOK-UP  
1. Flush the water supply line and securely attach it to the flare fitting or adapter located on rear of brewer.  
2. Turn on the water supply.  
INITIAL SETUP  
CAUTION: The brewer must be disconnected from the power source throughout the initial setup, except when  
specified in the instructions.  
1. Insert an empty funnel into the funnel rails of one of the brew stations.  
2. Place an empty server under the funnel.  
3. Connect the brewer to the power source. Main ON/OFF Switch (located in bottom cover behind right front  
leg on some brewers) must be in the ON position. Water will begin flowing into the tank and stop when the  
tank is filled to its capacity. Display will show PLEASE WAIT...TANK FILLING until tank is filled with water.  
4. Wait approximately twenty minutes for the water in the tank to heat to the proper temperature. Display will  
show READY TO BREW...WATER TEMP: XXX˚ when tank is at operating temperature.  
NOTE: Brew water temperature is factory set at 200° F (93.3° C). Areas of high altitude will require lowering  
this temperature to prevent boiling. Refer to chart in "SET TEMP" section when readjusting the brew  
temperature.  
5. Place a small vessel beneath the faucet and open the faucet handle. Release it when you hear the tank  
refilling.  
6. Water volumes have been preset at the factory. Refer to adjustments for the Set Brew Volumes section of  
this manual should the volume need to be increased or decreased.  
7. The brewer is now ready for use in accordance with the coffee brewing instructions.  
37614 042210  
Page 5  
OPERATING CONTROLS  
f
j
g
e
b
b
F
F
O
H
N/  
O
N
I
A
TC  
I
M
W
S
a
P3268.25  
h
d
d
h
c
c
OPERATING CONTROLS  
(a) MAIN ON/OFF SWITCH  
This switch, located under the brewer behind the right front leg, turns power on and off to all components  
in the brewer.  
(b) BATCH SELECTOR SWITCHES  
Pressing the switch corresponding to the Small, Medium, or Large batch selects the amount of coffee to be  
brewed. Pressing a different switch after a brew cycle has been initiated does not change the brew batch in  
progress. Light indicates the selected batch to brew.  
(c) ON/OFF SWITCH (ENABLE BREW)  
Pressing the ON/OFF switch alternately turns the brewing side on and off. Pressing this switch during the brew  
cycle will interrupt the brew cycle, stopping the flow of water. Pressing this switch during the programming  
of the brewer will exit the setup and return to the main screen.  
(d) BREW SWITCH  
Momentarily pressing and releasing this switch begins a brew cycle.  
(e) PROGRAM SWITCH  
Pressing and holding the upper right hidden switch allows entry to the programming menus. Pressing and  
releasing the switch steps through each function screen during programming.  
(f) FUNCTION SCREEN  
This is the display which shows the various functions of the brewer and allows the programming to be ac-  
complished.  
(g) FUNCTION SCREEN SWITCHES  
These are the hidden switches which are used to program the brewer.  
(h) FUNNEL SENSING COILS  
These are used to "receive" information from the Smart Funnel handle (coffee name and batch size), and also  
from RECIPE CARDS.  
(j) SCROLL BACKWARDS  
The upper left hidden switch can be used to scroll backwards through the function list.  
37614 040408  
Page 6  
COFFEE BREWING  
1. Select the desired batch size on the grinder. It is not necessary to select a size on the brewer.  
2. Insert a BUNN filter into the funnel.  
3. Pour the proper amount of fresh ground coffee into the filter and level the grounds by gently shaking.  
4. Slide the funnel into the funnel rails. If the grounds are not obtained through a grinder compatible with a  
Smart Funnel, a batch size must be chosen on the brewer.  
5. Place an empty server under the funnel.  
6 The ENABLE BREW switch must be ON. Momentarily press and release the BREW switch. If the brewer has  
the funnel lock option and if it is activated, once a brew cycle has been started the funnel is locked in place.  
There may be certain situations in which the brew cycle will not begin when the BREW switch is pressed:  
a) BREW TEMPERATURE TOO LOW - wait until heated or cancel BREW LOCKOUT option.  
b) FUNNEL NOT IN PLACE (or using a standard brew funnel) - cancel FUNNEL DETECT option.  
c) CHECK FUNNEL - remove funnel, empty previously brewed grounds and grind a new batch into the  
funnel.  
7. If none of the above messages are displayed, the display will read NOW BREWING and the time remaining  
in the brew cycle. Arrows will point to the side which is brewing. If both sides are brewing simultaneously,  
the arrows will alternate from left to right on the display.  
8. Following the BREW will be a countdown of drip time DRIPPING which shows the time remaining until the  
funnel lock will release. Discard the grounds and filter only after visible dripping stops.  
CLEANING  
1. The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning all  
surfaces on Bunn-O-Matic equipment.  
2. Check and clean the sprayhead. Use the pointed end of sprayhead cleaning tool (#38227.0000) to remove  
any mineral deposits from the sprayhead holes.  
3. Insert the long end of sprayhead cleaning tool into the sprayhead fitting, and rotate several times to remove  
any mineral deposits from the fitting.  
4. Insert the short end of sprayhead cleaning tool into the bypass fitting, and rotate several times to remove  
any mineral deposits from the fitting.  
NOTE: In hard water areas, this may need to be done daily. It will help prevent liming problems in the brewer  
and takes less than a minute.  
37614 080108  
Page 7  

Motorola V620 User Manual
MicroNet Technology Computer Drive MNFWUSB71702 User Manual
Maxtor OneTouch 1TB User Manual
LG Electronics VX9400MMBB022240110 User Manual
Kenwood KDC F324A User Manual
JVC CD RECEIVER KD LHX502 User Manual
Honeywell PCR11ELW User Manual
Craftsman 247797853 User Manual
Asus P525 User Manual
Apple POWERPC 5300CD User Manual