622
OWNERS MANUAL
for
AIRPOT &
THERMAL SERVER
COFFEE BREWERS
MODELS
8778 8780 8782
8783 8785 8786
8788
Includes:
Installation
Use & Care
Servicing Instructions
Model 8780 Brewer
with optional
7750 Thermal Server
PRINTED IN UNITED STATES OF AMERICA
p/n 75854 Rev. C ECN-12888
M622 050614 cps
TABLE OF CONTENTS
WARRANTY STATEMENT
Thank You for purchasing this
Bloomfield Industries appliance.
xi
1
2
3
3
4
6
8
SPECIFICATIONS
Proper installation, professional
operation and consistent
maintenance of this appliance will
ensure that it gives you the very
best performance and a long,
economical service life.
FEATURES & OPERATING CONTROLS
PRECAUTIONS & GENERAL INFORMATION
AGENCY LISTING INFORMATION
INSTALLATION INSTRUCTIONS
OPERATION
BREWING COFFEE
CLEANING INSTRUCTIONS
TROUBLESHOOTING SUGGESTIONS
SERVICING INSTRUCTIONS
Deliming Instructions
EXPLODED VIEWS & PARTS LISTS
WIRING DIAGRAMS
9
This manual contains the
10
11
16
18
22
information needed to properly
install this appliance, and to use,
care for and maintain or repair the
appliance in a manner which will
ensure its optimum performance.
SPECIFICATIONS
AMPS
1ø
15
POWER SUPPLY
CORD
MODEL
STYLE
VOLTS
WATTS
8778
8778CAk
THERMAL
120
120
120
120
120
1800
1500
1800
1500
1800
NEMA 5-15P
NEMA 5-15P
NEMA 5-15P
NEMA 5-15P
NEMA 5-15P
12.5
15
8780
THERMAL
AIRPOT
8780CAk
8782
8782CAk
12.5
15
120
120
1500
1800
12.5
15
NEMA 5-15P
NEMA 5-15P
8782XL
8782XLCAk
120
120
120
120
1500
1800
1500
1800
12.5
15
NEMA 5-15P
NEMA 5-15P
NEMA 5-15P
NEMA 5-15P
8783
AIRPOT
AIRPOT
8783CAk
8785
8785CAk
12.5
15
120
120
240
1500
1800
1800
12.5
15
7.5
NEMA 5-15P
NEMA 5-15P
NEMA 1-15P (non-polarized)
8785XL
8785XLPI
8786
THERMAL
AIRPOT
115/230
4 WIRE
3500
15
NONE
8788
115/230
4 WIRE
3500
5
NONE
k Meets Canadian standards.
This manual applies to the following Bloomfield Industries Gourmet 1000™ products:
8778
8780
8782
8778CA
8780AC
8782A
8782LCA
8783CA
8785ACA
8785XL
8786A
8778ACA
8780ACA
8782ACA
8782NFCA
8780CA
8782CA
8782XL
8780JCA
8782FCCA
8782XLCA
8780NFCA
8782JCA
8782XLCA
8782L
8783
8785
8785JCA
8785XLACA
8786J
8785XL
8785XLCA
8785CA
8785L
8785XLPI
8786
8788
8788KFT
8788L
8788WA
1
FEATURES AND OPERATING CONTROLS
Fig. 1 Features & Operating Controls
2
PRECAUTIONS AND GENERAL INFORMATION
WARNING: Electric Shock Hazard
All servicing requiring access to non-insulated components must be performed by qualified
service personnel. Do not open any access panels which require the use of tools. Failure to
heed this warning can result in electrical shock.
WARNING: Injury Hazard
All installation procedures must be performed by qualified personnel with full knowledge of all
applicable electrical and plumbing codes. Failure could result in property damage and
personal injury.
WARNING Electric Shock Hazard
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a
plumbing line will provide such a ground. Electrical shock will cause death or serious Injury.
WARNING: Burn Hazard
This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from
contact with dispensed liquids.
This appliance is intended for commercial use only.
CAUTION: Equipment
Electrical Damage
This appliance is intended for use to brew beverage products for
human consumption. No other use is recommended or
authorized by the manufacturer or its agents.
DO NOT plug in or energize this
appliance until all Installation
This appliance is intended for use in commercial establishments, Instructions are read and followed.
where all operators are familiar with the appliance use,
limitations and associated hazards. Operating instructions and
warnings must be read and understood by all operators and
users.
Damage to the Brewer will occur if
these instructions are not followed.
CAUTION:
Burn Hazard
Except as noted, this piece of equipment is made in the USA
and has American sizes on hardware. All metric conversions
are approximate and can vary in size.
Exposed surfaces of the
appliance, brew chamber and
Airpot or Server may be HOT to
the touch, and can cause serious
burns.
The following trouble shooting, component views and parts lists
are included for general reference, and are intended for use by
qualified service personnel.
This manual should be considered a permanent part of this
appliance. The manual must remain with the appliance if it is
sold or moved to another location.
AGENCY LISTING INFORMATION
This brewer is
and
listed under UL file E9253.
NOTE: Model 8785XLPI is not UL approved
E9253
STD 4
E9253
This brewer meets
Standard 4 only when installed,
operated and maintained in accordance with the enclosed
instructions.
3
INSTALLATION INSTRUCTIONS
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
IMPORTANT:
REFER TO EXPLODED VIEWS PAGES 18 thru 21 FOR
COMPONENT NAMES/NUMBERS
To enable the installer to make
a quality installation and to
minimize installation time, the
following suggestions and tests
should be done before the
actual unit installation is started:
Unpack the unit. Inspect all components for completeness and
condition. Ensure that all packing materials have been removed
from the unit.
Verify that the Spray Head Gasket (#33) and Spray Disk (#34)
are properly installed.
CAUTION: Equipment
Electrical Damage
LEVELING THE UNIT
Verify that an adjustable leg is installed at each corner of the
brewer, and that a rubber foot is installed on each leg.
DO NOT plug in or energize this
appliance until all Installation
Instructions are read and
followed. Damage to the
Brewer will occur if these
instructions are not followed.
Set Brewer in its operating location. Level the Brewer. A spirit
level should be placed on the top of the unit, at the edge, as a
guide when making level adjustments.
Level the unit from left to right and front to back by turning the
adjustable feet. Be sure all four feet touch the counter to prevent
tipping.
CAUTION: Unstable
Equipment Hazard
PLUMBER’S INSTALLATION INSTRUCTIONS (AUTOMATIC
BREWERS ONLY)
It is very important for safety
and for proper operation that the
brewer is level and stable when
standing in its final operating
position. Provided adjustable,
non-skid legs must be installed
at each corner of the unit.
Failure to do so will result in
movement of the brewer which
can cause personal Injury and/
or damage to brewer.
Brewer should be connected to a POTABLE WATER, COLD
WATER line. Flush water line before connecting to Brewer.
DO NOT use a saddle valve with a self-piercing tap for the water
line connection. Such a tap can become restricted by waterline
debris. For systems that must use a saddle tap, shut off the main
water supply and drill a 3/16” (minimum) tap for the saddle
connection, in order to insure an ample water supply. Remember
to flush the line prior to installing the saddle.
The brewer must be installed on a water line with average
pressure between 10 PSI and 90 PSI. If your water pressure
exceeds 90 PSI at anytime, a pressure regulator must be
installed in the water supply line to limit the pressure to not more
than 90 PSI in order to avoid damage to lines and solenoid.
NOTE: Water supply inlet line
must meet certain minimum
criteria to insure successful
operation of the brewer.
Bloomfield recommends 1/4"
copper tubing for installation of
less than 25 feet and 3/8" for
more than 25 feet from a 1/2"
water supply line.
A water shut-off valve should be installed on the incoming water
line in a convenient location (Use a low restriction type valve,
such as a 1/4-turn ball valve, to avoid loss of water flow thru the
valve.
NSF requires that the brewer be able to be moved for cleaning
underneath. A flex line or loops of copper tubing will satisfy this
requirement. See Fig. 2 at right.
4
INSTALLATION INSTRUCTIONS (continued)
NOTE: This equipment must be
installed to comply with all
applicable federal, state and
local plumbing codes and
ordinances.
WARNING ELECTRIC
SHOCK HAZARD:
Brewer must be properly
grounded to prevent possible
Fig. 2 Water Supply Installation
shock hazard. DO NOT
assume a plumbing line will
provide such a ground.
Electrical shock will cause death
or serious injury.
In some areas, local codes require a backflow preventer (check
valve) to be installed on the inlet water line. If a backflow
preventer is used, you must install a water hammer arrester in
the incoming line, between the backflow preventer and the
brewer inlet, as far away from the brewer as space will allow.
This will relieve the excessive back pressures that can cause
faucet leaks and solenoid malfunctions.
IMPORTANT: Do not connect
brewer to electrical power until
the tank is filled with water.
Pour water into the pour-over
opening until water flows from
the brew head.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
IMPORTANT: Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Models 8778, 8780, 8782, 8783 & 8785 are equipped with a cord
and plug. They require a 115 - 125 volt 15 amp circuit (50/60 Hz,
2 wire plus ground, with NEMA 5-15R receptacle).
IMPORTANT: The ground prong of the plug is part of a system
designed to protect you from electrical shock in the event of
internal damage. Never cut off the ground prong nor twist a
blade to fit an existing receptacle. Contact a licensed electrician
to install the proper circuit and receptacle.
Models 8786 & 8788 must be wired by an electrician, and
require a 115/230V 20A circuit (50/60 Hz, 2 hot legs / 1 neutral
leg, plus ground). Remove front panel to gain access to terminal
block. Green terminal must be connected to a suitable building
ground. Circuit must be capable of 3500 Watts.
See figure 3 at right.
IMPORTANT: Wiring must be installed in approved solid or
flexible conduit, and must be secured to the brewer with a strain
relief (to be provided by the installer).
Fig. 3 115/240 Volt Terminal Block
5
OPERATION
Fig. 4 Brewer Operation Diagram
IMPORTANT:
A. START-UP
Tank must be full of water
before connecting brewer
to electrical power.
For initial start-up, or if the brewer has not been used for an
extended period of time:
Heating elements will be
damaged if allowed to
operate without being fully
submerged in water.
Damage caused by
operating the brewer
without water in the tank
is NOT COVERED BY
WARRANTY.
Be sure spray disk and brew gasket are properly installed in the
brew head.
For automatic brewers, be sure the water supply is properly
connected and the water supply valve is turned ON.
BEFORE plugging the brewer into a receptacle, or otherwise
connecting brewer to electrical power THE WATER TANK MUST
BE FILLED. Place an empty container under the brew head. Lift
the pour-over cover then pour warm tap water into the pour-over
opening until water flows from the brew head. When water stops
dripping from the brew head, empty the container.
Once the tank is full of water, connect the brewer to electrical
power. The heating elements will begin heating the water in the
tank. When the water has reached the proper temperature, the
“READY TO BREW” light will glow.
6
OPERATION (continued)
WATER HEATER
Water temperature is sensed by a
thermobulb inserted into the water tank. This
temperature signal is fed to the thermostat,
which controls line power to the heating
element.
The setpoint temperature is adjustable at the
thermostat.
The element is protected from over-
temperature by a hi-limit thermostat.
Fig. 5 Heat Control Diagram
WATER FLOW
MANUAL
POUR-OVER
POUR-OVER FEATURE
BASIN
PAN
Pouring any amount of cold water into the
pour-over opening and into the basin pan
forces an identical amount of hot water out
of the tank and through the spray head into
the brew chamber.
BREW
TANK
AUTOMATIC OPERATION
SOLENOID
E
Pressing BREW button energizes the
solenoid valve, allowing water from an
external water supply to flow into the basin
pan and then into the hot water tank. This
forces an identical amount of hot water out
of the tank and through the spray head into
the brew chamber
MANUAL
POUR-OVER
BASIN
PAN
FAUCET
BYPASS
The solenoid uses a flow control device so
that flow is consistent between 20 p.s.i. and
90 p.s.i.
BREW
TANK
Length of time the solenoid is open is
controlled by the timer.
SOLENOID
E
FAUCET
SHUT-OFF
VALVE
FAUCET
HOT WATER FAUCET
The faucet water coil is submerged in the hot
water tank and draws heat from the brew
water. Water going to the water coil is not
controlled by the solenoid valve.
FAUCET
BYPASS
WATER
COIL
Hot water is provided at the faucet, at supply
water pressure, any time the faucet shut-off
valve is OPEN.
HOT
WATER
TANK
Fig. 6
7
BREWING COFFEE
CAUTION:
A. PREPARATION
Burn Hazard
Place one (1) genuine Bloomfield
paper filter in the brew chamber.
Add a pre-measured amount of
fresh coffee grounds.
Gently shake the brew chamber to
level the bed of grounds. Slide the
brew chamber into place under the
brew head.
Exposed surfaces of the
brewer, brew chamber
and airpot or server may
be HOT to the touch, and
can cause serious burns.
Fig. 7 Brew Chamber
CAUTION:
Burn Hazard
B. POUR-OVER OPERATION
NOTE: Any Gourmet 1000™ can be used in the pour-over mode.
To avoid splashing or
overflowing hot liquids,
ALWAYS place an empty
airpot or server under the
brew chamber before
starting the brew cycle.
Failure to comply can
cause serious burns.
BE sure “READY TO BREW” light is lit.
Place the appropriate EMPTY airpot or thermal server in place
under the brew chamber.
Fill an airpot or server, identical to the one being used, with tap
water. Lift the pour-over cover and pour the entire contents of the
container into the pour-over opening, which will fill the basin.
Water from the basin will displace a like amount of heated water
from the tank. The hot water will be forced into the brew head
where it will spray over the bed of grounds. Freshly brewed coffee
will begin to fill the container under the brew chamber. When the
flow and all dripping stops, the coffee is ready to serve.
CAUTION:
Burn Hazard
After a brew cycle, brew
chamber contents are
HOT. Remove the brew
chamber and dispose of
used grounds with care.
Failure to comply can
cause serious burns.
Discard the contents of the brew chamber. Rinse the brew
chamber in a sink. When the ”READY TO BREW” light glows, the
brewer is ready for another brew cycle.
C. AUTOMATIC OPERATION
NOTE:
BE sure “READY TO BREW” light is lit.
Water for the hot water
faucet is heated in a coil
inside of the water tank.
Use of the faucet will not
affect the volume of water
delivered for a brew.
However, overuse of the
faucet during a brew may
lower the temperature of
the brew water. Draw no
more than one (1) cup of
water at a time.
Place the appropriate EMPTY airpot or thermal server in place
under the brew chamber.
Press the “BREW” switch. The solenoid will open for an amount of
time determined by the timer setting, admitting a measured quantity
of water into the basin.
Water from the basin will displace a like amount of heated water
from the tank. The hot water will be forced into the brew head
where it will spray over the bed of grounds. Freshly brewed coffee
will begin to fill the container under the brew chamber. When the
flow and all dripping stops, the coffee is ready to serve.
Discard the contents of the brew chamber and rinse it in a sink.
When the ”READY TO BREW” light glows, the brewer is ready for
another brew cycle.
8
CLEANING INSTRUCTIONS
CAUTION:
Burn Hazard
PROCEDURE: Clean Coffee Brewer
PRECAUTIONS: Disconnect brewer from electric power.
Allow brewer to cool.
Brewing and serving
temperatures of coffee are
extremely hot.
Hot coffee will cause
serious skin burns.
FREQUENCY:
TOOLS:
Daily
Mild Detergent, Clean Soft Cloth or Sponge
Bristle Brush, Bottle Brush
CAUTION:
Electric Shock
Hazard
1. Disconnect brewer from electric power.
Allow brewer to cool before cleaning.
Do not submerge or immerse
brewer in water.
2. Remove airpot or thermal server.
3. Remove and empty brew chamber.
IMPORTANT:
4. Remove the spray disk from the brew head (See figure 8):
Press up on the spray disk ears, then turn the disk to the left
to unlatch. Remove the gasket from inside the brew head.
DO NOT use steel wool, sharp
objects, or caustic, abrasive or
chlorinated cleansers to clean
the brewer, airpots or thermal
servers.
5. Wipe inside of brew head and area around the brew head
with a soft clean cloth or sponge moistened with clean water.
6. Wash the spray disk in a sink using warm water and a mild
detergent. A bristle brush may be used to clear clogged
spray holes. Rinse the spray disk with clean water and allow
to air dry.
7. Wash the brew chamber in a sink using warm water and a
mild detergent. A bristle brush may be used to clean the
inside. Rinse with clean water and allow to air dry.
8. Wipe the exterior of the brewer with a soft clean cloth or
sponge moistened with clean water.
10. Reinstall the gasket INSIDE the brew head, then reinstall the
spray disk.
11. Reinstall the brew chamber.
12. DO NOT submerge airpots or thermal servers in water.
Clean airpots and thermal servers by filling with warm soapy
water. Scrub the inside with a bottle brush. Empty and rinse
with clean water. Wipe the exterior with a soft clean cloth or
sponge moistened with clean water. Invert and allow to air
dry.
Fig. 8 Cleaning
Procedure is complete
9
TROUBLESHOOTING SUGGESTIONS
SYMPTOM
POSSIBLE CAUSE
SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit
breaker tripped
Check power supply cord
Check / reset circuit breaker
Thermostat set too low
Set for desired temperature
Hi-Limit thermostat tripped
Allow to cool
Reset hi-limit (8786, 8788)
Damaged internal component or Examine wiring & connectors,
wiring
thermostat and heating element
Repair/replace as needed
Pourover - no water or too little
water added at startup
Be sure to add sufficient water
Coffee level low (pour-over)
Not enough water poured in
Too much coffee grounds
Timer out of adjustment
Increase water amount
Adjust amount of grounds
Adjust timer
Coffee level too high or low
(automatic)
Brew chamber overflows
Too many filter papers or wrong Use one (1) genuine Bloomfield
filter paper
filter per brew
Brew chamber dispense hole
plugged
Thoroughly clean brew chamber
Too much coffee or too fine a
grind
Adjust coffee amount and grind
Sprays water from brew head
No brew (automatic)
Spray gasket improperly
installed
Check/reinstall gasket on
INSIDE of brew head
Spray disk plugged
Clean spray disk
Turn water supply ON
Clean strainer
Water supply OFF
Solenoid strainer plugged
Water filter (if used) plugged
Bad BREW switch
Replace filter element
Replace switch
Damaged internal component
or wiring
Examine wiring & connectors,
brew switch and solenoid
Repair/replace as needed
No flow from hot water faucet
Poor coffee quality
Faucet valve turned OFF
Faucet plugged
Turn faucet valve ON
Disassemble faucet, clean
Adjust water temp 195-205ºF
Water not hot enough
Keep brewer, airpots and servers clean. Install a taste and odor
filter in water supply, and replace cartridges regularly.
Use a quality coffee with a consistent roast. Use proper grind and
amount of coffee per brew.
10
SERVICING INSTRUCTIONS
ACCESS PANELS
CAUTION
Electric Shock
Hazard
TOP PANEL:
Remove top panel to access hot water tank, thermostat, heating
elements, brew circuit tubing, faucet valve and piping.
Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel or warmer
plate.
Top panel is held by two screws at the rear and a retaining lip at
the front.
FRONT PANEL:
Remove front panel to access timer, terminal block and solenoid.
Front panel is held by two screws at the bottom and a retaining
lip at the top.
SOLENOID DOOR:
Remove solenoid door to access solenoid and plumbing
connections.
Solenoid door is held by two screws and a retaining lip.
TOP
PANEL
FRONT
PANEL
TIMER
BUTTON
PLUG
SOLENOID
DOOR
Fig. 9 Access Panels
11
SERVICING INSTRUCTIONS (continued)
CAUTION
Electric Shock
Hazard
TEMPERATURE ADJUSTMENT
Unplug power cord or turn circuit breaker OFF. Remove top
panel.
These procedures involve
exposed electrical circuits.
These procedures are to be
performed by qualified
Pull vent tube out of tank lid and insert a thermometer of known
accuracy in vent hole. Reconnect brewer to electrical power.
technical personnel only.
Fig. 10 Checking and Adjusting Brew Temperature
NOTE:
Place an empty container under brew chamber. Energize brewer
and pour one decanter (64 oz.) of cold water into pour-over
opening. When READY TO BREW light comes on, read
temperature displayed on thermometer.
Optimum brewing temperature
range is 195ºF to 205ºF (90ºC
to 96ºC).
IMPORTANT:
Adjust thermostat by turning shaft; clockwise increases
temperature. 1/8 turn = approximately 10ºF.
Refer to Table 1 below for proper brewing temperature based on
altitude.
A mechanical thermostat will
maintain temperature within
±5ºF. To prevent boiling water
in the brewer, thermostat should
be adjusted to a maximum
temperature equal to the local
boiling temperature minus 5ºF.
Table 1 Boiling Temperature by Altitude
Upon completion, remove thermometer and reinstall vent tube.
12
SERVICING INSTRUCTIONS (continued)
TIMER ADJUSTMENT (AUTOMATIC BREWERS ONLY)
IMPORTANT: Water pressure
must be between 20 p.s.i and
The amount of water dispensed automatically during a brew cycle
is controlled by the timer.
90 p.s.i. flowing pressure.
If water pressure exceeds this
value, or if water pressure
varies greatly, a pressure
regulator must be installed in
the water supply line.
Place empty airpot or thermal server under brew chamber. Press
BREW button. Brewer should dispense one container of water.
To adjust amount:
Remove brew chamber and button plug. Adjust knob on timer;
clockwise increases time. Run several cycles to check amount of
water delivered. Replace button plug.
REMOVE TANK LID ASSEMBLY
Unplug brewer or turn circuit breaker OFF. Turn OFF water
supply. Remove top panel. Pull vent tube and inlet elbow out of
basin pan.
IMPORTANT: Before setting
assembly into tank, make sure
tank lid gasket is properly
seated on flange of lid.
On automatic models, pull water inlet tube out of basin pan.
Remove basin pan.
DO NOT OVER-TIGHTEN.
On models with faucet, disconnect inlet pipe at faucet shut-off
valve and outlet pipe at faucet.
Disconnect all wiring from thermostat, hi-limit, and heating
element.
Loosen center screw on tank hold-down bracket. Remove
hold-down bracket by sliding short slotted end off of locking stud
and lifting it off. Remove cover assembly by lifting it straight up.
Reassemble in reverse order.
REPLACE THERMOSTAT
IMPORTANT: When mounting
thermostat, be sure a new seal
washer is placed below the
fitting on the capillary line.
Push sensing bulb thru tank lid
until fitting seats.
Tighten capillary lock nut only
enough to ensure no water
leakage. Excessive tightening
is not necessary.
Unplug brewer or turn circuit breaker OFF. Turn OFF water
supply. Remove top panel.
Disconnect all wiring from thermostat only. Loosen and free jam
nut from pass-thru fitting securing temperature sensing bulb.
Remove two screws holding thermostat to bracket.
Lift out thermostat, sensing bulb and thermostat gasket.
Reassemble in reverse order.
REPLACE HEATING ELEMENT
IMPORTANT: When replacing
heating element, also replace
seal gaskets.
Remove tank lid assembly per above.
Remove two hex nuts holding element to cover. Pull element
from mounting holes.
Reassemble in reverse order.
13
SERVICING INSTRUCTIONS (continued)
REPLACE SOLENOID
Symptom: Automatic brewer will not flow water; or,
automatic brewer drips continuously from brew head.
Unplug power cord or turn circuit breaker OFF. Turn OFF and
disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Remove two screws holding access door in place. Remove two
screws holding solenoid to door.
Disconnect wiring from solenoid.
Slide the 7/16" end of the wrench between the valve body and
the white ring on the extreme end of the metal hose fitting.
Pressure on the white ring toward the metal ferrule releases the
clinch ring, allowing the hose to be easily slid off of the solenoid
bypass outlet.
Transfer solenoid bracket to new solenoid.
Reinstall hose by pressing end of hose onto bypass outlet until it
is fully seated.
Reassemble in reverse order.
CLEAN SOLENOID SCREEN (NEW-STYLE)
Symptom: Automatic brewer will not flow water.
Unplug power cord or turn circuit breaker OFF. Turn OFF and
disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Using needle-nose pliers, withdraw strainer screen from solenoid.
Clean screen under faucet. A stiff bristle brush may be used if
necessary.
Reinsert screen in solenoid. Be careful to maintain correct
orientation. (The OPEN END of the screen goes in FIRST.)
Reassemble in reverse order.
Fig. 11 Remove Faucet
Supply from Solenoid
Fig. 12 Clean Strainer Screen
14
SERVICING INSTRUCTIONS (continued)
REPLACE TIMER ASSEMBLY
Unplug power cord or turn circuit breaker OFF.
Remove front panel. Remove knob and three screws holding
timer to bracket. Disconnect wiring to timer.
Reassemble in reverse order.
Adjust timer as described on page 13
IMPORTANT: When replacing
water faucet coil, also replace
seal gaskets.
REPLACE HOT WATER FAUCET COIL
Symptom: Brewer drips continuously from brew head, except
when faucet valve is turned OFF.
Remove tank lid assembly per above.
Remove two hex nuts hot water coil to cover. Pull coil from
mounting holes.
Reassemble in reverse order.
REPAIR HOT WATER FAUCET
NOTE: Any abrasion or
roughness on the flat end of the
seat cup will require replacing
the seat cup:
Remove top panel and turn faucet valve OFF.
Unscrew aerator cap from faucet and remove handle retaining
clip. Do not let faucet body turn.
Work the seat cup out of the
bonnet and off of the end of the
stem.
Pull bonnet assembly from faucet body.
Examine the interior of the faucet body and the surface of the
seat cup. Clean out any debris in the faucet body, using a stiff
bristle brush if necessary.
Install a new seat cup, making
sure the knob on the stem is
fully inserted into the pocket of
the seat cup, and the skirt of the
seat cup is fully inserted into the
bonnet.
Examine the aerator. Clean any debris from the screen or flow
straightener, using a stiff bristle brush if necessary.
Reassemble in reverse order.
REPLACE BREW READY LIGHT or BREW BUTTON
Unplug power cord or turn circuit breaker OFF. Disconnect
electric leads.
Using Switch Removal Tool (p/n 83209) or a thin screwdriver,
compress mounting tabs then pry light or switch from mounting
hole.
Reassemble in reverse order.
15
SERVICING INSTRUCTIONS (continued)
CAUTION -
CHEMICAL BURN
HAZARD
PROCEDURE: Delime the Water Tank
PRECAUTIONS: Disconnect brewer from electric power.
Allow brewer to cool.
Deliming chemicals are caustic.
Wear appropriate protective
gloves and goggles during this
procedure.
Never siphon deliming
chemicals or solutions by
mouth.
FREQUENCY:
TOOLS:
As required (Brewer slow to heat)
Deliming Solution
Protective Gloves, Goggles & Apron
Mild Detergent, Clean Soft Cloth or Sponge
Bristle Brush, Bottle Brush
This operation should only be
performed by qualified and ex-
perienced service personnel.
Large Sink (or other appropriate work area)
1. Disconnect brewer from the electrical supply. For automatic
brewers, turn off the water shut-off valve and disconnect the
water supply line from the brewer inlet fitting.
IMPORTANT: DO NOT spill,
splash or pour water or deliming
solution into or over any internal
component other than the inside
of the water tank.
2. Remove the tank lid assembly as described on page 13.
3. Remove the water tank from the brewer body by lifting
straight up. Empty all water from the tank. Set the tank back
into the brewer.
IMPORTANT: DO NOT allow
any internal components to
come into contact with the
deliming solution. Take care to
keep all internal components
dry.
4. Mix 2 quarts of deliming solution according to the
manufacturer’s directions. Carefully pour the deliming
solution into the water tank. Lower the lid assembly back
onto the tank. Allow to sit for 30 minutes, or as directed by
the manufacturer.
5. At end of soaking period, remove lid assembly from tank.
Thoroughly rinse internal components of lid assembly with
clear water. Using a stiff bristle brush, scrub the heating
element (and faucet water coil on automatic brewers) to
remove lime and calcium build-up. Rinse with clean water.
Store lid assembly in a safe location .
NOTE: Repeat steps 4 thru 5
as required to remove all scale
and lime build-up.
6. Remove the tank from the brewer and empty. Using a stiff
bristle brush, scrub the interior of the water tank to remove
lime and calcium build-up. Rinse with clean water.
16
SERVICING INSTRUCTIONS (continued)
7. Set the tank back into the brewer. Reassemble the tank lid to
NOTE: Normally, silicone
hoses do not need to be
delimed. Should deliming
hoses become necessary,
Bloomfield recommends
replacing the hoses.
the water tank. Make sure the gasket is properly in place,
then reinstall the hold-down strap.
8. Reinstall wiring to heating element and thermostat. Reinstall
the hi-limit thermostat (if removed). For automatic brewers,
reassemble piping for the faucet. Verify that all internal
components are dry, then reinstall the top panel.
10. Reconnect brewer to electrical supply and, for automatic
brewers, reconnect water supply.
11. Install the brew chamber without filter paper or grounds.
Run at least three full brew cycles and discard all water
generated.
12. Brewer is ready to use.
17
EXPLODED VIEW & PARTS LIST
HOT WATER TANK ASSEMBLY
ITEM
13
14
16
17
50
54
56
58
59
60
61
62
PART NO. DESCRIPTION
8043-5 Hold Down Strap
8043-506 Nut, 8-32 SS Acorn
USED ON
All
All
All
All
All
All
8780, 8782, 8786, 8788
8780, 8782, 8786, 8788
All
All
60366
Screw, 1/20x1-1/4 SS Cap Head
69401
Nut, Hex 1/4-20 SS
86280
Thermostat w/Thermo Well
Tank Cover Gasket
Seal Gasket
Hot Water Coil
Inlet Elbow
8043-12
8043-30
8540-6
8043-8
8043-15
8043-11
8512-45
8514-68
8043-83
8552-50
8543-74
8543-73
8043-24
82299
Vent Tube
Outlet Elbow
All
Tank Cover (Plate Only, 6 holes)
Tank Cover (Plate Only, 8-holes)
Hi-Limit Thermostat (120V)
Hi-Limit Thermostat (240V)
Nut, Hex 4-40 SS
Screw, 4-40x1 SS Pan Head
Water inlet Tube
Tank Heating Element 120V / 1800W
Tank Heating Element 120V / 1500W
Tank Heating Element 240V / 3500W
Tank Body
8788, 8783, 8785
8780, 8782, 8786, 8788
All, except 8786 & 8788
8786, 8788
All
All
All
All U.S., except 8786 & 8788
All Canadian, except 8786 & 8788
8786, 8788
All
63
64
65
66
67
8043-14
8716-1
8043-10
68
COMPLETE SPARE TANK COVER
85574
Spare Cover Assembly (120V, 1800 W
8780, 8782, 8786, 8788
(U.S.)
8780, 8782, 8786, 8788
(Canadian)
8788, 8783, 8785
(U.S.)
8788, 8783, 8785
(Canadian)
No Coil - all parts mounted to cover)
Spare Cover Assembly (120V, 1500 W
No Coil - all parts mounted to cover)
Spare Cover Assembly (120V, 1800W
With Coil - all parts mounted to cover)
Spare Cover Assembly (120V, 1500W
With Coil - all parts mounted to cover)
Spare Cover Assembly (230V, 3800W
With Coil - all parts mounted to cover)
8543-300
85575
8541 WF-300
8716-300
8786, 8788
18
EXPLODED VIEW & PARTS LIST (continued)
ELECTRICAL COMPONENTS
ITEM
31
32
PART NO.
8707-55
8718-31
8718-1
DESCRIPTION
USED ON
8780, 8782, 8786, 8788
All
All
Brew Switch, Momentary Rocker
Ready-To-Brew Light, green
Timer
35
36
36t
37
6407-15
8552-18
35-210
8541-120
85753
86280
8552-18
85309
8043-83
8552-50
82299
8043-14
8716-1
Cord & Cap Assembly
Terminal Strip
Strain Relief
Solenoid Valve (old-style)
Solenoid Valve (new-style)
Thermostat w/Thermo Well
Terminal Block 4-Pole
Terminal Block 3-Pole
Hi-Limit Thermostat
All, except 8786 & 8788
8786, 8788
All, except 8786 & 8788
All
All
All
45
50
51
8786, 8788
8778, 8780, 8782, 8783, 8785
All, except 8786 & 8788
8786, 8788
All U.S., except 8786 & 8788
All Canadian, except 8786 & 8788
8786, 8788
63a
63b
67
Hi-Limit Thermostat
Tank Heating Element 120V / 1800W
Tank Heating Element 120V / 1500W
Tank Heating Element 240V / 3500W
SOLENOID REPAIR KITS
83612
85685
85218
Solenoid Complete, Single
Solenoid, Complete, with Bypass
Inlet Fitting Kit (contains cap, inlet fitting washer
and strainer)
85219
Inlet Strainer only
19
EXPLODED VIEW & PARTS LIST (continued)
INTERNAL PLUMBING COMPONENTS
ITEM
8
9
PART NO.
8540-3
8540-4
8551-30
8514-26
85681
8540-30
8043-13
82556
8543-42
82727
8543-45
84715
DESCRIPTION
USED ON
8780, 8782, 8786, 8788
8780, 8782, 8786, 8788
8780, 8782, 8786, 8788
8780, 8782, 8786, 8788
8780, 8782, 8786, 8788
8780, 8782, 8786, 8788
All
8780, 8782, 8786, 8788
All
All
All
8780, 8782, 8786, 8788
All
All
8778
Faucet Outlet Tube Assembly
Formed Inlet Tube Assembly
1/4“ Male Flare x 1/8” FPT
Needle Valve (Faucet Shut-Off)
Faucet Inlet Tube Assy
Elbow
Sprayer Elbow
Faucet Assembly
Spray Head Gasket
Spray Disk
Spray Head Retainer
Water Inlet Tube
Solenoid Valve
Vent Tube
Basin Pan (Pour-Over Deep)
Basin Pan (Automatic)
Basin Pan (Pour-Over)
10
11
12
18
25
29
33
34
34a
43
45
60
108
109
85753
8043-15
8541-21
8543-29
8780, 8782, 8786, 8788
8778, 8783, 8785
c1
d1
e3
82681
8551-100B
82680
Washer
7/16“ Lock Washer
Hex Lock Nut
8780, 8782, 8786, 8788
8780, 8782, 8786, 8788
8780, 8782, 8786, 8788
FAUCET REPAIR KITS
82573
82575
82576
Handle (item 29a)
Seat Cup (item 29c)
Faucet Repair Kit (Includes 29a Handle, 29c Seat Cup, 29d Spring, 29h Stem,
29j Pin & 29k Bonnet
82682
84804
84870
Retainer Clip (item 29b)
Aerator Replacement Kit (Includes 29e O-Ring, 29f Aerator Disk & 29g Aerator Cap
Aerator Repair Kit (Includes 29e O-Ring & 29f Aerator Disk)
20
EXPLODED VIEW & PARTS LIST (continued)
CABINET COMPONENTS
ITEM
21
PART NO.
63201
DESCRIPTION
Spacer, .171 ID x .375 LG
USED ON
8782XL, 8785XL
22
87192
Positioning Bracket
8782XL, 8785XL
33
34
8543-42
82727
Spray Head Gasket
Spray Disk
All
All
34a
70
8543-45
8706-75
Spray Head Retainer
Button Plug (Timer)
All
8780, 8782, 8786, 8788
71
72
Cap, Plastic, Lower Support
Support, Lower
All
All
73
74
8033-55
8033-56
81732
8543-69
8810-12
Leveler, Adjustable Leg
Cap, Adjustable Leg
Adjustable Leg Assembly
Heyco Bushing
Button Plug (Non-Faucet)
Body Assembly
All
All
All
All
75
77
101
102
103
104
8778, 8783, 8785
All
All
8786, 8788
All
8778, 8773, 8775
8780, 8782, 8786, 8788
All
All
8778
Front Panel
Mounting, Hi-Limit Switch
Door, Solenoid (old style)
Door, Solenoid (new style)
Door, Solenoid (new-style)
Pour-Over Assembly
Top Panel
Basin Pan (Pour-Over Deep)
Basin Pan (Automatic)
Basin Pan (Pour-Over)
Label, Gourmet 1000
Basin Body Assembly
Brew Chamber, Black
Brew Chamber, Brown
Brew Chamber, Stainless
Bloomfield Paper Filter (pk 1000)
8572-34
8572-34
85089
105
106
108
86666
8542-6
8760-3
8541-21
8543-29
8780, 8782, 8786, 8788
8783, 8785
109
110
200
All
All
All
All
All
All
8942-6B
8942-6
8707-6
POF
210
21
WIRING DIAGRAM
22
WIRING DIAGRAM (continued)
23
Bloomfield Industries proudly supports CFESA
Commercial Food Equipment Service Association
Bloomfield Industries, Inc.
Division of Carrier Commercial Refrigeration
In US and Canada
Telephone: 775-689-5700
Fax:
Fax:
888-492-2783
800-356-5142 (for orders only)