Agilent Technologies hard disk drive kit e5052 90202 User Manual |
Agilent E5052BU Option 018
Hard Disk Drive Kit
User’s Guide
First Edition
Manufacturing No. E5052-90202
May 2007
1
General Information
This chapter describes the Hard Disk Drive Kit, contents of the kit, and required tools to
install the Option 018 into the Agilent E5052B.
3
General Information
Option 018 Hard Disk Drive Kit
Option 018 Hard Disk Drive Kit
The purpose of this kit is to install the option 018 into the Agilent E5052B.
Contents of the Agilent E5052BU Option 018 Hard Disk
Drive Kit
The kit includes the parts listed in Table 1-1. If anything is missing, contact the nearest
Agilent Technologies office.
Table 1-1
Contents of the Agilent E5052BU Option 018 Hard Disk Drive Kit
Description
Qty.
Upgrade Manual (This manual)
HDD Assembly
1
1
4
Chapter1
2
Option Installation
This chapter describes the procedure to install the option 018 into the Agilent E5052B.
5
Option Installation
Introduction
Introduction
This chapter describes the procedure to install Option 018 into the E5052B. The procedure
consists of the following items.
•
•
•
•
•
•
•
Installation Requirement
Saving System calibration Data from Removable Hard Disk to USB Pen Drive
Removing Removable Hard Disk
Mounting Removable Hard Disk
Initial Registration of E5052B
Calibration of the Touch Screen
Recalling System Calibration Data from USB Pen drive to Removable Hard Disk
Procedure
Installation Requirement
•
•
5188-4426 Key for Hard Disk Carrier
USB Pen Drive (Over 512MB)
6
Chapter2
Option Installation
Procedure
Saving System calibration Data from Removable Hard Disk to USB
Pen Drive
The following is a description of the procedures to save the system calibration data stored
in the removable hard disk to a USB Pen drive.
Step 1. Exit the measurement window.
System > Service Menu > Administorator Menu > Exit E5052B > OK
Step 2. Insert a USB Pen drive into the USB port in front panel.
Step 3. Open D:\Recovery drive.
Step 4. Click .D:\syscal from the explorer.
Step 5. Select Edit - Copy from menu bar of the explorer.
Step 6. Click the USB Pen drive of the explorer.
Step 7. Select Edit - Paste from menu bar of the explorer.
Step 8. Click .D:\limit from the explorer.
Step 9. Select Edit - Copy from menu bar of the explorer.
Step 10. Click the USB Pen drive of the explorer.
Step 11. Select Edit - Paste from menu bar of the explorer.
Step 12. Turn off the E5052B, and then remove the cord from the outlet before removing the
Removable Hard Disk.
Chapter 2
7
Option Installation
Procedure
Removing Removable Hard Disk
Follow the steps below to remove a removable hard disk.
CAUTION
Before removing a hard disk, you must turn off the unit’s power and then disconnect the
power cord from the outlet.
Step 1. Turn off the power.
Step 2. Insert the key in the lock and turn anti-clockwise.
Step 3. Open the screw in clockwise direction.
Step 4. Press the button under direction.
Step 5. Remove the hard disk.
Mounting Removable Hard Disk
Follow the steps below to mount a removable hard disk.
Step 1. Insert the hard disk into the slot.
Step 2. Turn the screw in anti-clockwise direction until it is locked.
Step 3. Turn the key to the right until it is locked.
Step 4. Remove the key.
Step 5. Turn on the E5052B.
8
Chapter2
Option Installation
Procedure
Initial Registration of E5052B
When you start up the E5052B at the first time, you need to perform the initial registration
of the Windows XP operating system of the E5052B.
NOTE
NOTE
You cannot use the front panel keys during the initial registration of the E5052B therefore
connect the mouse and the keyboard before turning on the power.
If you perform the following procedure incorrectly, a message asking you whether to return
to the previous registration screen and perform the registration appears. In this case, follow
the instruction to return to the previous registration screen.
Step 1. Turns on the E5052B.
Step 2. The Windows XP Professional Setup wizard appears. Click the Next > button (Figure 2-1).
Figure 2-1
Windows XP Professional Setup wizard
e5071cse1073
Chapter 2
9
Option Installation
Procedure
Step 3. In the Windows XP Professional Setup dialog box, select the I accept this agreement box
and click the Next >button (Figure 2-2).
Figure 2-2
Windows XP Professional Setup dialog box (1/2)
e5071cse1074
Step 4. In the next dialog box , input E5052 in the Name box. Then, click the Next> button (Figure
2-3).
Figure 2-3
Windows XP Professional Setup dialog box (2/2)
E5052
e5052bse1033
Step 5. After a while, the E5052B restart automatically. Then, the measurement display appears.
10
Chapter2
Option Installation
Procedure
Calibration of the Touch Screen
When you have replaced the HDD on an E5052B, you have to calibrate the touch screen.
Follow the procedure described below to calibrate the touch screen.
Step 1. Press
.
Step 2. Press Service Menu.
Step 3. Press Test Menu.
Step 4. Press Adjust Touch Screen.
The touch screen calibration screen (Figure 2-4) appears.
Figure 2-4
Touch Panel Calibration Screen
Step 5. Touch the x mark on the upper left with your finger. The mark x appears also on the lower
left, upper right, and lower right. Touch the x marks in that order with your finger.
Touching the four locations described above with your finger automatically concludes the
touch screen calibration.
NOTE
With no operation on the touch screen calibration screen for a preset time, it automatically
closes and the previous measurement screen reappears.
Chapter 2
11
Option Installation
Procedure
Recalling System Calibration Data from USB Pen drive to Removable
Hard Disk
The following is a description of the procedures to copy the system calibration data stored
in the USB Pen drive to the removable hard disk.
Step 1. Exit the measurement window.
System > Service Menu > Administorator Menu > Exit E5052B > OK
Step 2. Insert a USB pen drive in to the USB port in front panel.
Step 3. Open D:\Recovery drive.
Step 4. Click syscal folder in the USB Pen drive from the explorer.
Step 5. Select Edit - Copy from menu bar of the explorer.
Step 6. Click the D:\ of the explorer.
Step 7. Select Edit - Paste from menu bar of the explorer.
Step 8. Click limit folder in the USB Pen drive from the explorer.
Step 9. Select Edit - Copy from menu bar of the explorer.
Step 10. Click the D:\ of the explorer.
Step 11. Select Edit - Paste from menu bar of the explorer.
Step 12. Restart E5052B
12
Chapter2
REGIONAL SALES AND SUPPORT OFFICES
For more information about Agilent Technologies test and measurement products, applications, services, and
of the following centers and ask for a test and measurement sales representative.
21/01/2004
United States:
Australia/New Zealand:
Test and Measurement Call Center
(tel) 1 800 452-4844
(fax) 1 888 900-8921
(tel) (61 3) 9210-5555 (Australia)
(fax) (61 3) 9210-5899
(tel) (64 4) 939-0636 (New Zealand)
(fax) (64 4) 972-5364
Canada:
Test and Measurement Call Center
(tel) 1 877 894-4414
(fax) 1 888 900-8921
Asia Pacific:
(tel) (65) 6375-8100
(fax) (65) 6836-0252
Email: [email protected]
China:
(tel) 800 810-0189
(fax) 800 820-2816
Europe:
(tel) (31 20) 547-2323
(fax) (31 20) 547-2390
Japan:
Call Center
(tel) 0120 421-345
(tel) (81) 426 56-7832
(fax) (81) 426 56-7840
Korea:
(tel) (82 2) 2004-5004
(fax) (82 2) 2004-5115
Latin America:
(tel) (305) 269-7500
(fax) (305) 269-7599
Taiwan:
(tel) 0800 047 866
(fax) 0800 286 331
|