Advantech Computer Accessories EKI 12741F User Manual

EKI-2741F  
10/100/1000Base-T to SFP  
(mini-GBIC) Type Fiber  
Optic Media Converter  
EKI-2741SX  
10/100/1000Base-T to  
1000Base-SX SC Type  
Fiber Optic Media  
Converter  
EKI-2741LX  
10/100/1000Base-T to  
1000Base-LX SC Type  
Fiber Optic Media  
Converter  
User Manual  
Product Warranty (2 years)  
Advantech warrants to you, the original purchaser, that each of its products will be free from  
defects in materials and workmanship for two years from the date of purchase.  
This warranty does not apply to any products which have been repaired or altered by persons  
other than repair personnel authorized by Advantech, or which have been subject to misuse,  
abuse, accident or improper installation. Advantech assumes no liability under the terms of  
this warranty as a consequence of such events.  
Because of Advantechs high quality-control standards and rigorous testing, most of our  
customers never need to use our repair service. If an Advantech product is defective, it will be  
repaired or replaced at no charge during the warranty period. For out-of-warranty repairs, you  
will be billed according to the cost of replacement materials, service time and freight. Please  
consult your dealer for more details.  
If you think you have a defective product, follow these steps:  
1. Collect all the information about the problem encountered. (For example, CPU speed,  
Advantech products used, other hardware and software used, etc.) Note anything  
abnormal and list any onscreen messages you get when the problem occurs.  
2. Call your dealer and describe the problem. Please have your manual, product, and any  
helpful information readily available.  
3. If your product is diagnosed as defective, obtain an RMA (return merchandize  
authorization) number from your dealer. This allows us to process your return more  
quickly.  
4. Carefully pack the defective product, a fully-completed Repair and Replacement Order  
Card and a photocopy proof of purchase date (such as your sales receipt) in a shippable  
container. A product returned without proof of the purchase date is not eligible for  
warranty service.  
5. Write the RMA number visibly on the outside of the package and ship it prepaid to your  
dealer.  
iii  
Declaration of Conformity  
CE  
This product has passed the CE test for environmental specifications. Test conditions for  
passing included the equipment being operated within an industrial enclosure. In order to  
protect the product from being damaged by ESD (Electrostatic Discharge) and EMI leakage,  
we strongly recommend the use of CE-compliant industrial enclosure products.  
FCC Class A  
This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference when the equipment is operated in a  
commercial environment. This equipment generates, uses and can radiate radio frequency  
energy and, if not installed and used in accordance with the instruction manual, may cause  
harmful interference to radio communications. Operation of this equipment in a residential  
area is likely to cause harmful interference in which case the user will be required to correct  
the interference at his own expense.  
Technical Support and Assistance  
Step 1. Visit the Advantech web site at www.advantech.com/support where you can find  
the latest information about the product.  
Step 2. Contact your distributor, sales representative, or Advantech’s customer service  
center for technical support if you need additional assistance. Please have the  
following information ready before you call:  
- Product name and serial number  
- Description of your peripheral attachments  
- Description of your software (operating system, version, application software,  
etc.)  
- A complete description of the problem  
- The exact wording of any error messages  
EKI-2741F-SX-LX User Manual  
iv  
Safety Instructions  
1. Read these safety instructions carefully.  
2. Keep this User's Manual for later reference.  
3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not  
use liquid or spray detergents for cleaning.  
4. For plug-in equipment, the power outlet socket must be located near the equipment and  
must be easily accessible.  
5. Keep this equipment away from humidity.  
6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may  
cause damage.  
7. The openings on the enclosure are for air convection. Protect the equipment from  
overheating. DO NOT COVER THE OPENINGS.  
8. Make sure the voltage of the power source is correct before connecting the equipment to  
the power outlet.  
9. Position the power cord so that people cannot step on it. Do not place anything over the  
power cord.  
10. All cautions and warnings on the equipment should be noted.  
11. If the equipment is not used for a long time, disconnect it from the power source to avoid  
damage by transient overvoltage.  
12. Never pour any liquid into an opening. This may cause fire or electrical shock.  
13. Never open the equipment. For safety reasons, the equipment should be opened only by  
qualified service personnel.  
14. If one of the following situations arises, get the equipment checked by service personnel:  
a. The power cord or plug is damaged.  
b. Liquid has penetrated into the equipment.  
c. The equipment has been exposed to moisture.  
d. The equipment does not work well, or you cannot get it to work according to the user's  
manual.  
e. The equipment has been dropped and damaged.  
f. The equipment has obvious signs of breakage.  
15. DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE  
TEMPERATURE MAY GO BELOW -40(-40) OR ABOVE 85(185). THIS  
COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A  
CONTROLLED ENVIRONMENT.  
v
Safety Precaution - Static Electricity  
Follow these simple precautions to protect yourself from harm and the products from damage.  
1. To avoid electrical shock, always disconnect the power from your PC chassis before you  
work on it. Don't touch any components on the CPU card or other cards while the PC is  
on.  
2. Disconnect power before making any configuration changes. The sudden rush of power  
as you connect a jumper or install a card may damage sensitive electronic components.  
EKI-2741F-SX-LX User Manual  
vi  
Contents  
Chapter 1 Overview...........................................2  
1.1 Introduction.........................................................2  
1.1.1 Fast Fiber Converters Module...................2  
1.1.2 Dual Power Input.......................................2  
1.1.3 Flexible Mounting ......................................2  
1.1.4 Advanced Protection .................................2  
1.1.5 Wide Operating Temperature....................2  
1.1.6 Easy Troubleshooting................................2  
1.2 Features..............................................................3  
1.3 Specification .......................................................4  
1.4 Packing List ........................................................6  
1.5 Safety Precaution ...............................................6  
Chapter 2 Installation........................................8  
2.1 LED Indicators ....................................................8  
Table 2.1: EKI-2741F/SX/LX LED Definition.............8  
2.2 DIP-Switch..........................................................9  
Table 2.2: EKI-2741series DIP-Switch Definition........9  
2.3 Dimensions (units: mm)....................................10  
Figure 2.1: Front View of EKI-2741 series.................10  
Figure 2.2: Side View of EKI-2741 series ..................11  
Figure 2.3: Rear View of EKI-2741 series..................12  
Figure 2.4: Top View of EKI-2741 series...................13  
2.4 Mounting...........................................................14  
2.4.1 Wall mounting..........................................14  
Figure 2.5: Combine the Metal Mounting Kit.............14  
2.4.2 DIN-rail Mounting.....................................15  
Figure 2.6: Installation to DIN-rail Step 1...................15  
Figure 2.7: Installation to DIN-rail Step 2...................16  
2.5 Network Connection .........................................17  
Figure 2.8: Transceiver to the SFP module.................17  
Figure 2.9: Transceiver Inserted..................................17  
Figure 2.10: LC connector to the transceiver ..............18  
Figure 2.11: Remove LC connector ............................18  
Figure 2.12: Pull out from the SFP module.................19  
2.6 Power Connection ............................................20  
Figure 2.13: Pin Assignment of the Power Connector 20  
Chapter 3 Troubleshooting ............................22  
Appendix A Pin Assignment & Wiring ...........24  
Figure A.1: RJ-45 Pin Assignment..............................24  
Figure A.2: EIA/TIA-568B .........................................24  
Figure A.2: EIA/TIA-568A.........................................24  
vii  
Contents  
EKI-2741F-SX-LX User Manual  
viii  
Overview  
Sections include:  
z
z
z
z
z
Introduction  
Features  
Specifications  
Packing List  
Safety Precaution  
Chapter 1 Overview  
1.1 Introduction  
The EKI-2741 is designed to convert Gigabit Ethernet networks to Gigabit fiber  
networks by transparently converting Ethernet signals to optic signals. The advantages  
of fiber optics are wide bandwidth, EMI immunity and long-distance transmission  
capability. Therefore, EKI-2741 is an ideal solution for “fiber to building” applications at  
central offices or local sites. EKI-2741 supports MDI/MDIX auto detection, so you don’t  
need to use crossover wires. Furthermore, the EKI-2741 can work normally from -10 ~  
60o C and accepts a wide voltage range from +12 ~ 48 VDC. Besides, it also provides  
3,000 VDC surge (EFT) protection against over-voltage, so it is suitable for harsh  
operating environments.  
1.1.1  
Fast Fiber Converters Module  
The EKI-2741F/SX/LX provides you with one Fiber connector for your fiber optic cable  
and one Ethernet RJ-45 port (Auto MDI/MDIX) for your 1000Base-TX copper cable  
connection. There are two DIP-switches to set the operation mode for UTP, Fiber ports  
and link loss forwarding function.  
1.1.2  
Dual Power Input  
To reduce the risk of power failure, the EKI-2741F/SX/LX provide +12 ~ 48 VDC dual  
power inputs. If there is power failure, EKI-2741F/SX/LX will automatically switch to the  
secondary power input.  
1.1.3  
Flexible Mounting  
EKI-2741F/SX/LX are extremely compact and can be mounted on a DIN-rail or a panel,  
so it is suitable for any space-constrained environment.  
1.1.4  
Advanced Protection  
The power line of EKI-2741F/SX/LX supports up to 3,000 VDC EFT protection, which  
secure equipment against unregulated voltage and make systems safer and more  
reliable. Meanwhile, 4,000 VDC ESD protections for Ethernet ports make EKI-  
2741F/SX/LX more suitable for harsh environments.  
1.1.5  
Wide Operating Temperature  
The operating temperature of the EKI-2741F/SX/LX is between -40 ~ 75 (wide  
operating temperature model) or -10 ~ 60 (standard model). With such a wide range,  
you can use the EKI-2741F/SX/LX in some of the harshest industrial environments that  
exist.  
1.1.6  
Easy Troubleshooting  
LED indicators make troubleshooting quick and easy. The 10/100/1000 Base-TX port  
has 2 LEDs that display the link status, transmission speed and collision status. Also  
the three power indicators P1, P2 and P-Fail help you diagnose immediately.  
EKI-2741F-SX-LX User Manual  
2
1.2 Features  
Provides 1 x SFP (mini-GBIC) type connector (EKI-2741F)  
Provides 1 x 1000Base-SX or 1000Base-LX SC type connector (EKI-2741SX/LX)  
Provides 1 x 10/100/1000Mbps Ethernet ports with RJ-45 connector  
Supports full/half duplex flow control  
Supports MDI/MDI-X auto-crossover  
Supports surge (EFT) protection 3,000 VDC for power line  
Supports 4,000 VDC Ethernet ESD protection  
Embedded with a switch controller, supports auto-negotiation  
Supports store & forward transmission  
Supports redundant +12 ~ 48 VDC power input  
Provides flexible mounting: DIN-rail, Wall Mounting  
Supports operating temperatures from -40 ~ 75 (wide operating temperature  
model) or -10 ~ 60 (standard model)  
3
Chapter1  
1.3 Specification  
Communications  
IEEE 802.3, 802.3ab, 802.3u, 802.3x,  
802.3z  
Standard  
10/100/1000Base-TX, 1000Base-SX,  
1000Base-LX  
LAN  
Multi-Mode Fiber: 550m (EKI-2741SX)  
Single-Mode Fiber: 10km (EKI-2741LX) or  
SFP (mini-GBIC) Fiber: Up to 110km (EKI-2741F)  
Ethernet: Up to 100 meters (STP or UTP)  
Up to 1000 Mbps  
Transmission Distance  
Transmission Speed  
Interface  
Fiber : 1 x SFP(mini-GBIC) fiber connector  
(EKI-2741F)  
Connectors  
1 x SC type fiber connector (EKI-2741SX/LX)  
1 x RJ-45  
6-pin removable screw terminal (power & relay)  
TX port: 10/100/1000M, Link/Active  
Fiber port: LNK/ACT  
LED Indicators  
Port Alarm, LFP  
Power  
5.28 W (EKI-2741F)  
5.18 W (EKI-2741SX)  
5.30 W (EKI-2741LX)  
2 x Unregulated +12 ~ 48 VDC  
1 Relay Output  
Power Consumption  
Power Input  
Fault Output  
Mechanism  
37 x 95 x 140 mm  
Dimensions (WxDxH)  
Enclosure  
Mounting  
IP30, Metal shell with solid mounting kits  
DIN-rail, wall  
Protection  
4,000 VDC  
ESD (Ethernet)  
Surge (EFT for power)  
Reverse Polarity  
Overload  
3,000 VDC  
Yes  
0.9A@12VDC (25 ℃)  
EKI-2741F-SX-LX User Manual  
4
Environment  
-10 ~ 60 (14~140)  
Operating Temperature  
Wide temp. model: -40 ~ 75 ℃ (-40 ~ 167℉)  
-40 ~ 85 (-40 ~ 185)  
Storage Temperature  
Operating Humidity  
Storage Humidity  
5 ~ 95% (non-condensing)  
0 ~ 95% (non-condensing)  
Certifications  
UL, 60950-1, CAN/CSA-C22.2 No.60950  
U.S.A.: FCC Part 15 CISPR 22  
EU: EN55011, EN61000-6-4  
EN55022, Class A,  
Safety  
EMC  
EN61000-3-2/3  
EN55024  
IEC61000-4-2/3/4/5/6/8/11/12  
EN61000-6-2  
IEC60068-2-32  
Free Fall  
Shock  
Vibration  
IEC60068-2-27  
IEC60068-2-6  
5
Chapter1  
1.4 Packing List  
1 x EKI-2741F or EKI-2741SX or EKI-2741LX Industrial Ethernet Switch  
1 x eAutomation Industrial Communication CD-ROM with software, and User manual  
2 x Wall Mounting Bracket and Screws  
1 x DIN-rail Mounting Bracket and Screws  
1 x EKI-2741F/SX/LX Startup Manual  
1 x DC Jack Cable φ2.0/150mm  
1.5 Safety Precaution  
Attention  
IF DC voltage is supplied by an external circuit, please use a protection device  
on the power supply input.  
EKI-2741F-SX-LX User Manual  
6
Installation  
Sections include:  
z
z
z
z
z
LED Indicators  
Dimensions  
Mounting  
Network Connection  
Power Connection  
Chapter 2 Installation  
In this chapter, you will be given an overview of the EKI-2741F/SX/LX hardware  
installation procedures.  
2.1 LED Indicators  
There are few LEDs display the power status and network status located on the front  
panel of EKI-2741F/SX/LX, each of them has its own specific meaning as the table  
below.  
Table 2.1: EKI-2741F/SX/LX LED Definition  
LED  
Color  
Description  
On  
Power input 1 is active  
Power input 1 is inactive  
P1  
Green  
Off  
On  
Power input 2 is active  
P2  
Green  
Red  
Off  
Power input 2 is inactive  
On  
Power input 1 or 2 has failed  
Power input 1 and 2 are both functional, or no power input  
Connected to network  
P-Fail  
Off  
On  
LNK/ACT (fiber port)  
Green  
Yellow  
Green  
Flashing  
Off  
Networking is active  
Not connected to network  
Link to 1000M bps network  
Not connected to network  
Connected to network  
On  
1000M  
(RJ-45)  
Off  
On  
LNK/ACT (RJ-45)  
Flashing  
Off  
Networking is active  
Not connected to network  
EKI-2741F-SX-LX User Manual  
8
2.2 DIP-Switch  
The DIP-Switch is used to configure operation mode for LFP (Link Fault Pass-  
Through) and operation mode for UTP/Fiber port. The default value of DIP-switch is  
OFF.  
Table 2.2: EKI-2741series DIP-Switch Definition  
S/W No  
Status  
ON  
Description  
Enables Port/Power Alarm  
Disable Port/Power Alarm  
Enables LFP  
1
OFF  
ON  
2
OFF  
Disables LFP  
Link Fault Pass-Through (DIP-Switch 2): When LFP is enabled, it allows UTP link  
failures to be reported to the fiber side and also allows Fiber link failures to be reported  
to the UTP side. Therefore, a link loss forwarding feature is provided in both UTP and  
Fiber side.  
Note  
Please don’t change the DIP-switch setting when UTP or fiber port is  
transmitting or receiving data. It may cause some data error. Besides, if you  
change the DIP-switch setting, please power off the converter and power on  
again to make the setting effective.  
9
Chapter2  
2.3 Dimensions (units: mm)  
Figure 2.1: Front View of EKI-2741 series  
EKI-2741F-SX-LX User Manual  
10  
Figure 2.2: Side View of EKI-2741 series  
11  
Chapter2  
Figure 2.3: Rear View of EKI-2741 series  
EKI-2741F-SX-LX User Manual  
12  
The terminal block of power & relay is located on the top side. Please refer to page 16 for pin  
assignment.  
Figure 2.4: Top View of EKI-2741 series  
13  
Chapter2  
2.4 Mounting  
The EKI-2741F/SX/LX support two mounting methods: DIN-rail & Wall.  
2.4.1  
Wall mounting  
EKI-2741F/SX/LX can be wall-mounted by using the included mounting kit. Then, hang  
on the EKI-2741F/SX/LX to the nails on the wall.  
First, use the screws included in the package to combine the EKI-2741F/SX/LX and  
metal mounting kit. And then you can install the device firmly via the components,  
please see Figure 2.5 as below.  
Figure 2.5: Combine the Metal Mounting Kit  
EKI-2741F-SX-LX User Manual  
14  
2.4.2  
DIN-rail Mounting  
You can also mount EKI-2741F/SX/LX on a standard DIN-rail by below steps.  
The DIN-rail kit is screwed on the industrial switch when out of factory. If the DIN-rail kit  
is not screwed on the industrial switch, please screw the DIN-rail kit on the switch first.  
First, hang the EKI-2741F/SX/LX to the DIN-rail with angle of inclination. See figure 2.6.  
Figure 2.6: Installation to DIN-rail Step 1  
15  
Chapter2  
Then, let the device down straight to slide over the rail smoothly. See Figure 2.7  
Figure 2.7: Installation to DIN-rail Step 2  
EKI-2741F-SX-LX User Manual  
16  
2.5 Network Connection  
Twisted-pair segment can use unshielded twisted pair (UTP) or shielded twisted pair  
(STP) cabling. The cable between the link partner (switch, hub, workstation, etc.)  
and the converter, must be less than 100 meters (328 ft.) long and comply with the  
IEEE 802.3ab 1000Base-T standard for Category 5e or above.  
Fiber segment using single-mode connector type must use 9/125 µm single-mode  
fiber cable. You can connect two devices in the distance of 10 km.  
Fiber segment using multi-mode connector type must use 50/125 or 62.5/125 um  
multi-mode fiber cable. You can connect two devices up to 550m distances.  
The small form-factor pluggable (SFP) is a compact optical transceiver used in  
optical communications for both telecommunication and data communication  
applications.  
To connect the transceiver and LC cable, please follow the steps shown below:  
First, insert the transceiver into the SFP module. Notice that the triangle mark is the bottom of  
the module.  
Figure 2.8: Transceiver to the SFP module  
Figure 2.9: Transceiver Inserted  
17  
Chapter2  
Second, insert the fiber cable of LC connector into the transceiver.  
Figure 2.10: LC connector to the transceiver  
To remove the LC connector from the transceiver, please follow the steps shown below:  
First, press the upper side of the LC connector from the transceiver and pull it out to release.  
Figure 2.11: Remove LC connector  
EKI-2741F-SX-LX User Manual  
18  
Second, push down the metal loop and pull the transceiver out by the plastic part.  
Figure 2.12: Pull out from the SFP module  
19  
Chapter2  
2.6 Power Connection  
The EKI-2741F/SX/LX support dual +12 ~ 48 VDC power inputs and power-fail relay  
output.  
Figure 2.13: Pin Assignment of the Power Connector  
You can connect an alarm indicator, buzzer or other signaling equipment through the  
relay output. The relay opens if power input 1 or 2 fails ( “Open” means if you connect  
relay output with an LED, the light would be off).  
EKI-2741F-SX-LX User Manual  
20  
Troubleshooting  
Chapter 3 Troubleshooting  
1.  
Power Input  
Verify that is using the right power cord/adapter (+12~48 VDC), please don’t use the  
power adaptor with DC output voltage higher than 48V, or it will burn this converter  
down.  
2.  
Cable  
Select the proper UTP/Fiber cable to construct your network. The single-mode  
converter must use single-mode fiber cable. Please check that you are using the right  
cable.  
3.  
DIP Switch  
Check the configuration DIP-switch. It must be setting in the same operation mode with  
the link partner.  
4.  
Diagnosing LED Indicators  
The switch can be easily monitored through panel indicators, which describes common  
problems user may encounter and where user can find possible solutions, to assist in  
identifying.  
If the power indicator does not light up when the power cord is plugged in, user may  
have a problem with power cord. Then check for loose power connections, power  
losses or surges at power outlet. If user still cannot resolve the problem, contact the  
local dealer for assistance.  
If the Industrial switch LED indicators are normal and the connected cables are correct  
but the packets still cannot transmit, please check your system’s Ethernet devices  
configuration or status.  
EKI-2741F-SX-LX User Manual  
22  
Pin Assignment & Wiring  
Appendix A Pin Assignment & Wiring  
It is suggested to adopt ELA/TIA as the wiring of the RJ-45.  
Figure A.1: RJ-45 Pin Assignment  
Figure A.2: EIA/TIA-568B  
Figure A.2: EIA/TIA-568A  
EKI-2741F-SX-LX User Manual  
24  

Mr Coffee SK23 User Manual
Motorola IDEN I370XL User Manual
Motorola 6803578F42 User Manual
Kyocera Topaz 901 User Manual
Hitachi Travelstar 5K500B User Manual
Emerson SMARTSET CKS1850C User Manual
Crosley Radio Crosley Director CR2406A User Manual
Clarion CD Player M109 User Manual
Black Box IEEE 1284 Serial→Parallel Converter 26658 User Manual
Addonics Technologies ADCFASTMS User Manual