1. Description  
• Remote access to the field devices means less site visits  
for operations and maintenance  
• Industrial grade TCP/IP router: several serial and TCP/IP  
based field devices can be integrated into a central  
supervisory and control system (SCADA)  
Wireless I/O Gateway ARR600 provides wireless monitoring  
and control of field devices via cellular network from a central  
site or a control center. The devices offer industrial quality  
connectivity for the IEC 60870 and Modbus based protocols.  
Field applications can be connected and controlled via built-in  
digital and analog I/O’s. Wireless I/O Gateway ARR600  
exhibits integrated communication capability and seamless  
integration to the SCADA systems.  
• Optimizing the cost of communication by using public  
cellular networks  
2. Complete communication system  
Wireless I/O Gateway ARR600 is a member of ABB’s Arctic  
product family and part of its 600 Wireless Gateway product  
series.  
Wireless I/O Gateway ARR600 is part of a complete  
communication system that consists of Arctic 600 series  
gateways and a central M2M Gateway ARM600  
communication server. The M2M gateway is an essential part  
of the total communication solution and offers features that  
are needed to build a reliable end-to-end communication  
system.  
With Wireless I/O Gateway ARR600, conventional  
IEC60870-101 devices can be attached to a modern TCP/IP  
based IEC 60870-5-104 control system. This is made  
possible by the protocol conversion from IEC 60870-5-101 to  
IEC 60870-104. ARR600 also supports Modbus RTU to  
Modbus TCP protocol conversion.  
• Static IP addressing for Arctic 600 series devices –  
Possibility to use operator independent standard SIM  
cards  
• VPN Concentrator – Secure communication between a  
central location and remote sites  
• Arctic Patrol – Centralized device management  
application for the Arctic 600 series devices monitoring  
and controlling  
By using Wireless I/O Gateway ARR600, Ethernet and serial  
devices can be attached to a TCP/IP based control system.  
DNP3 serial devices can also be attached to a DNP3 TCP  
SCADA system. In this case, the DNP3 protocol is transferred  
to TCP/IP communication (transparent serial gateway mode).  
Wireless I/O Gateway ARR600 can be utilized for various  
industrial and utility applications to maximize the benefits.  
• Firewall – A network security system to control the  
incoming and outgoing network traffic  
• Built-in I/O capability enables the remote monitoring and  
control of the switching devices  
• Integrated protocol conversion enables connecting the  
legacy serial-based devices into a TCP/IP based  
supervisory control system (SCADA)  
• Ideal for retrofitting by allowing the user to extend the life  
cycle of existing serial-based substation devices due to  
the integrated protocol converter  
GUID-76591882-F5CF-4D17-8464-6FE4197921BE V1 EN-US  
Figure 1. Communication system overview with Wireless I/O Gateway ARR600 and disconnector control  
ABB  
3
   
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
3. Application  
type of field devices. For example, these field devices  
can securely report the condition monitoring information,  
which allows planning of preventative maintenance.  
• Backup connectivity for any communication link  
Wireless I/O Gateway ARR600 can be used in the feeder  
automation and substation applications to automate  
distribution network in cooperation with the other ABB grid  
automation equipment. Further, the devices can be used in  
secondary substations for monitoring of transformers as well  
as other monitoring and control applications.  
Key features  
• Digital I/O and analog input interfaces  
• Support for multiple communication protocols for  
controlling of I/O ports  
ARR600 can be used in various industrial applications.  
• Protocol converter for multiple communication protocols  
• Enables always-on TCP/IP routing and serial over TCP/IP  
based two-way communication  
• Arctic Patrol connectivity supervision of the  
communication  
• Generic remote I/O interface for an upper-level system,  
for example, for directly controlling a load-break switch  
• Connecting IEC-101 or Modbus RTU protocol based  
meters and fault passage indicators into an upper-level  
system  
• Secure communication maintained with VPN and Firewall  
• Providing a fast, reliable and secure wireless link  
between Ethernet devices, such as COM600 Substation  
Management Unit and 615 series protection relays  
• Enables remote service and maintenance opportunities  
by allowing the service personnel to remotely access any  
Distribution  
substation  
Power generation  
Reclosers  
VPN  
GPRS/3G/LTE  
Cellular network  
Internet  
VPN  
ARM600  
Secondary  
substation  
Control room  
SCADA / DMS  
Consumers  
GUID-E9E4368B-4014-4974-A662-C50D01401F02 V1 EN-US  
Figure 2. Communication solution in distribution automation overview  
4
ABB  
 
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
4. Physical interfaces  
For communication to an upper-level system, ARR600  
Wireless I/O Gateway ARR600 has two I/O variants called  
IO-1 and IO-2. IO-1 has 8 binary inputs and 2 binary outputs  
while IO-2 has 6 binary inputs, 4 binary outputs and 2 analog  
inputs.  
supports 4G (LTE) connectivity, but is also compatible with  
GPRS and 3G..  
LED panel description  
The LED panel of the device contains ten LEDs to indicate the  
complete operational status of the device.  
ARR600 has two serial ports (RS-232, RS-485) and one LAN  
port (RJ-45) for device connectivity.  
1
2
3
4
5
6
7
8
9 10  
GUID-899117C2-BDBC-4D56-A277-299AC3E6120A V2 EN-US  
Figure 3. LEDs  
1
2
3
4
5
6
7
8
9
Batt.  
Status  
Power/Error  
Function  
Eth 1  
Eth 2  
Led 1  
Led 2  
Led 3  
10 Led 4/Cellular  
ABB  
5
 
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
Table 1. Description of available LEDs  
LED  
1
Label  
Batt  
State  
Description  
-
LED unassigned  
2
Status  
On  
VPN connection is up  
Flashing  
VPN connection is starting  
VPN connection is disabled  
Operating power is turned on  
Operating power is turned off  
Device is starting  
Off  
3
4
Power/Error  
Function  
On  
Off  
On  
Flashing  
Device is operating normally  
Device is not operational  
Ethernet link is up  
Off  
5
Eth 1  
On  
Flashing  
Ethernet link is transferring data  
Ethernet link down  
Off  
6
Eth 2  
-
LED reserved for future use  
LED reserved for future use  
LED reserved for future use  
LED reserved for future use  
Cellular connections up and active  
Cellular connection is inactive  
7
Led 1  
-
8
Led 2  
-
9
Led 2  
-
10  
Led 4/Cellular  
Flashing  
Off  
6
ABB  
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
Front panel  
1
2
3
4
5
6
7
8
GUID-5A2B7768-3994-4264-86AB-939B14E2D5EE V2 EN-US  
Figure 4. Front panel with IO-1  
1
2
3
4
5
6
7
8
Power supply 12...48 VDC  
IO-1 digital I/O connector (only in certain product models)  
LAN/WAN port  
Console/application serial port  
Power switch  
Console/serial port switch  
DIP switches  
Application serial port  
ABB  
7
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
1
2
3
4
5
6
7
8
GUID-50B15E54-D86B-4361-B9B8-9BD5AFAA66C7 V2 EN-US  
Figure 5. Front panel with IO-2  
1
2
3
4
5
6
7
8
Power supply 12...48 VDC  
IO-2 digital and analog I/O connector (only in certain product models)  
LAN/WAN port  
Console/application serial port  
Power switch  
Console/serial port switch  
DIP switches  
Application serial port  
Back panel  
1
2
GUID-BB2AF55E-76F0-4C5D-87C2-EACC9F0088BA V1 EN-US  
Figure 6. Back panel  
1
2
Antenna connector SMA (female)  
SIM card slot  
Antenna panel description  
The SIM card slot and antenna connector can be found on  
the antenna panel.  
8
ABB  
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
5. Communication  
ARR600 provides a secure and reliable communication  
Wireless I/O Gateway ARR600 provides a complete solution  
for integrating the remote serial (RS-232/RS-485) or Ethernet  
devices with a central management system over a GPRS, 3G  
or LTE connection. Several interfaces are available for field  
device connectivity: digital inputs and outputs, analog inputs,  
serial and Ethernet ports. Industrial protocols IEC-104 and  
Modbus TCP are supported for the SCADA connectivity. With  
the Wireless I/O Gateway ARR600 protocol conversion  
feature, conventional IEC-101 and Modbus serial devices can  
be connected in a reliable way to modern TCP/IP based  
IEC-104 and Modbus TCP control systems.  
solution with support for secure VPN communication, static  
IP routing, an intelligent self-testing system, NAT, port  
forwarding and a firewall for monitoring IP traffic and blocking  
unwanted connections.  
The inputs and outputs can be accessed and controlled with  
IEC-104 and Modbus TCP protocols.  
More information is available in the Technical data section of  
this product guide or technical manual available at  
ABB  
9
 
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
6. Technical data  
Table 2. Dimensions  
Description  
Value  
Width × Height × Depth  
Weight  
108 × 45 × 175 mm (without antenna)  
590...610 g  
Table 3. Hardware  
Description  
Value  
Processor environment  
Processor  
Memory  
32 bit RISC  
128 MB Flash  
128 MB RAM  
Power  
Power supply  
12…48 VDC, limited (<240 VA) power source that fulfills the  
requirements of standard IEC 60950-1  
Power consumption  
Internal clock  
1...5 W  
Other  
Real time  
Approvals  
CE  
Environmental conditions  
Temperature range  
-30...+70°C (operating)  
-40...+85°C (storage)  
5...85% RH (non condensing)  
IP30  
Humidity  
Protection class  
Table 4. Supported protocols  
Master protocol  
IEC 60870-5-104  
IEC 60870-5-104  
Modbus TCP  
Slave protocol  
IEC 60870-5-101  
Modbus RTU/ASCII, Modbus TCP  
Modbus RTU/ASCII  
TCP/IP, UDP/IP (DNP3)  
Serial gateway - serial port data stream (such as DNP3)  
Table 5. Supported protocols for I/O controlling  
Master protocol  
IEC 60870-5-104  
Modbus TCP  
SNMP  
10  
ABB  
 
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
1
2
GUID-BCCDAFB3-3A96-42E6-A55E-8CC66E37133B V3 EN-US  
Figure 7. I/O connector pin numbering for IO-1  
1
2
Pin 1  
Pin 15  
Table 6. I/O connector pins for IO-1 (8DI+2DO)  
Pin  
1
Symbol  
V+  
Description  
Vcc out  
2
DI_1  
Digital input, 5...60 V  
Digital input, 5...60 V  
Digital input, 5...60 V  
Digital input, 5...60 V  
Digital input, 5...60 V  
Digital input, 5...60 V  
Digital input, 5...60 V  
Digital input, 5...60 V  
Digital inputs reference input  
3
DI_2  
4
DI_3  
5
DI_4  
6
DI_5  
7
DI_6  
8
DI_7  
9
DI_8  
10  
11  
12  
13  
14  
15  
DI_COM  
DO_1A  
DO_1B  
DO_2A  
DO_2B  
GND  
Digital output pole 1, 0...60 V, 100 mA  
Digital ouput pole 2  
Digital output pole 1, 0...60 V, 100 mA  
Digital output pole 2  
GND output  
ABB  
11  
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
1
2
3
4
GUID-37D5163F-322B-4D9F-908D-5493C81E8F8A V3 EN-US  
Figure 8. I/O connector pin numbering for IO-2  
1
2
3
4
DIO pin 1  
DIO pin 12  
AIO pin 1  
AIO pin 8  
12  
ABB  
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
Table 7. I/O connector pins for IO-2 (6DI+4DO+2AI)  
Pin/connector  
Type  
Description  
AIO_1  
Analog input  
Positive pin of analog input 1, 4...20 mA, ±1.5  
mA (-10...+55°C, 4...20 mA)  
AIO_2  
AIO_3  
Analog input  
Analog input  
Negative pin of analog input 1  
Positive pin of analog input 2, 4...20 mA, ±1.5  
mA (-10...+55°C, 4...20 mA)  
AIO_4  
AIO_5  
AIO_6  
AIO_7  
AIO_8  
DIO_1  
DIO_2  
DIO_3  
DIO_4  
DIO_5  
DIO_6  
DIO_7  
DIO_8  
DIO_9  
DIO_10  
DIO_11  
DIO_12  
Analog input  
Analog input  
Analog input  
Vcc output +  
Vcc output +  
Digital input  
Digital input  
Digital input  
Digital input  
Digital input  
Digital input  
Common  
Negative pin of analog input 2  
Not connected  
Not connected  
DC supply output +  
DC supply output -  
5...60 V  
5...60 V  
5...60 V  
5...60 V  
5...60 V  
5...60 V  
Common pin of the digital inputs  
Digital output pole 1, 0...60 V, 100 mA  
Digital output pole 1, 0...60 V, 100 mA  
Digital output pole 1, 0...60 V, 100 mA  
Digital output pole 1, 0...60 V, 100 mA  
Common pin of the digital outputs  
Digital output  
Digital output  
Digital output  
Digital output  
Digital output  
ABB  
13  
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
Table 8. Network interfaces  
Description  
Value  
Ethernet ports  
Ethernet/LAN  
10/100 Base-T. Shielded RJ-45  
1.5 kV isolation transformer  
Ethernet IEEE 802-3, 802-2  
RS-232 DTE  
Serial ports  
Serial 1/Console  
Male DB-9 connector  
IEC 60870-5-101 protocol support  
Full serial and modem signals  
300...460 800 bps  
Data bits: 7 or 8  
Stop bits: 1 or 2  
Parity: None, Even, Odd  
Flow control: None, RTS/CTS  
Protection: 15 kV ESD and short circuit  
Console: RS-232, 19200 bps, 8 data bits, 1 stop bit, no parity (8N1)  
RS-232 DTE, RS-422, RS-485 (selectable)  
Male DB-9 connector  
Serial 2  
IEC 60870-5-101 protocol support  
Full serial and modem signals  
300...460 800 bps  
Data bits: 7 or 8  
Stop bits: 1 or 2  
Parity: None, Even, Odd  
Flow control: None, RTS/CTS  
Protection: 15 kV ESD and short circuit  
Table 9. Electromagnetic compatibility tests  
Description  
Reference  
Emission tests according to the  
test specification IEC 61850-3  
(Edition 2.0 2013-12)  
Radiated disturbance  
CISPR 16-2-3  
Conducted disturbance  
CISPR 16-2-1  
Immunity tests according to the  
test specification IEC 61850-3  
(Edition 2.0 2013-12)  
Electrostatic discharge (ESD)  
EN 61000-4-2 (2008-12)  
Radiated radiofrequency  
electromagnetic field  
EN 61000-4-3 (2006-02)  
EN 61000-4-4 (2012-04)  
EN 61000-4-5 (2005-11)  
Electrical fast transient (EFT)  
Surge  
Conducted radiofrequency  
electromagnetic field  
EN 61000-4-6 (2008-10)  
EN 61000-4-8 (2009-09)  
Power frequency magnetic field  
14  
ABB  
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
Table 10. RoHS and REACH compliancy  
Description  
Reference  
Directive  
RoHS directive 2002/95/EC  
REACH directive 2006/1907/EC  
ABB  
15  
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
7. Mounting  
the antenna performance to a very high extent. In this case, it  
is highly recommended to use the optional external antenna  
with appropriate cable. This allows for better positioning of  
The devices have been equipped with mounting  
arrangements that are specially designed for DIN rail  
mounting. A set of DIN rail mounting clips is recommended to the devices, antennas and thus optimal performance.  
be used when mounting. The device should be mounted  
Another restriction to the positioning of the device during  
preferably inside a robust, locked and weatherproof control  
installation is that it should be mounted in such a way that the  
cabinet.  
required environmental conditions that are set in the  
As the device uses a cellular radio for data transmission, the  
surrounding environment can negatively affect the efficacy of  
these radio signals. Therefore, if a device with the antenna is  
mounted on the antenna connector, the unit should not be  
placed in a location where the radio signal might be  
shadowed, and therefore deteriorated by nearby obstacles or  
enclosures.  
Technical data section of this product guide are met.  
8. Ordering data  
The product label contains basic information about the unit  
such as product name, serial number and Ethernet MAC  
address.  
The product label is found at the bottom of the device.  
The large metallic surfaces, racks or walls with metallic  
structures (cabling, concrete iron, and so on) may degrade  
Table 11. Ordering data  
Description  
Radio IF  
ARR600A3261NA  
ARR600A3262NA  
LTE  
LTE  
Data speed max  
See the mobile data reference guide  
(2NGA001029).  
See the mobile data reference guide  
(2NGA001029).  
LAN/WAN  
1
1
RS-232/RS-485  
2
2
SIM card  
1
1
Supply voltage  
12...48 VDC  
12...48 VDC  
Modbus RTU to Modbus TCP conversion  
IEC-101 to IEC-104 conversion  
DNP3 serial over TPC/IP  
IO-1 (8DI+2DO)  
x
x
x
x
x
x
x
-
IO-2 (6DI+4DO+2AI)  
Supported protocols for I/O controlling  
-
x
IEC-104, Modbus TCP, SNMP  
IEC-104, Modbus TCP, SNMP  
16  
ABB  
   
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
9. Accessories and ordering data  
Table 12. Accessories  
Description  
Order code  
DIN rail mounting kit  
2RCA028234  
2RCA037240  
2RCA037243  
2RCA037244  
2RCA037245  
2RCA037246  
2RCA037645  
2RCA037647  
3G puck antenna (SMA male)  
I/O connector (IO-1 variants)  
I/O connector (IO-2 variants) analog input connector  
I/O connector (IO-2 variants) digital input connector  
Power supply (excluding power cord)  
Accessory kit  
Power cord (European plug)  
SMA(m)/FME(m) adapter1)  
2RCA037659  
2RCA037660  
2RCA041790  
2RCA041792  
Laird LTE antenna 700...2700 MHz (SMA male)  
European power supply (including 2RCA037246 and 2RCA037647)  
I/O connector kit (IO-2 variants) (including 2RCA037244 and 2RCA037245)  
1)  
Needed for single SIM Arctic products, if the third party antenna's connector type is FME female  
10. Tools  
11. References  
The devices can be configured using a graphical user  
interface via a Web based browser. A conventional console  
interface is also provided. Software updates or configuration  
adjustments for the devices can be made remotely by  
uploads over the network from the central control center.  
The abb.com/substationautomation portal provides  
information on the entire range of distribution automation  
products and services.  
ABB  
17  
   
Wireless I/O Gateway  
ARR600  
1MRS758464 E  
Product version: 3.4.7  
12. Document revision history  
Document revision/date  
A/2015-12-18  
Product version  
History  
A
First release  
Content updated  
B/2017-06-07  
3.3  
C/2017-09-22  
3.4  
Content updated to correspond to the product version  
Content updated to correspond to the product version  
Content updated  
D/2019-04-24  
3.4.7  
3.4.7  
E/2021-05-31  
18  
ABB  
 
19  
ABB Distribution Solutions  
Digital Substation Products  
P.O. Box 699  
FI-65101 VAASA, Finland  
Phone  
+358 10 22 11  
abb.com/mediumvoltage  
© Copyright 2021 ABB. All rights reserved.  

Nikon Cell Phone Accessories J3 User Manual
Kyocera Jax S1300 User Manual
Kenwood Z919 User Manual
Kenwood DP M6650 User Manual
JVC CD Receiver KD G807 User Manual
IBM ThinkCentre 9212 User Manual
Helio PN 810 User Manual
Apple IBOOK 073 0581 User Manual
American DJ PRO DJ1 User Manual
American Audio Radius 3000 User Manual