Toshiba MA 600 User Manual

TEC Electronic Cash Register  
MA-600 SERIES  
Programming Manual  
Document No. EO3-11106  
Original  
Dec., 2005  
(Revised  
)
PRINTED IN JAPAN  
EO3-11106  
Page  
6.21 Department Listing Capacity (LC) Programming.........................................................6-106  
6.22 Key Sticker Printing ....................................................................................................6-109  
6.23 PLU Table Programming ............................................................................................6-113  
6.24 PLU Preset Price Setting or Changing........................................................................6-120  
6.25 PLU Preset-Code Key Setting ....................................................................................6-123  
6.26 %+ and %- Preset Rate Setting..................................................................................6-128  
6.27 VAT or Add-on Tax Rate Setting ................................................................................6-130  
6.28 Foreign Currency Exchange Rate Setting...................................................................6-132  
6.29 Negative Amount Key Limit Amount Setting ...............................................................6-135  
6.30 Time Setting or Adjustment ........................................................................................6-137  
6.31 Date Setting or Adjustment.........................................................................................6-138  
6.32 Store/Register No. Setting..........................................................................................6-140  
6.33 Hourly Range Table Setting........................................................................................6-142  
6.34 Tone Volume Setting..................................................................................................6-146  
6.35 Report Item Print/Non-Print Setting.............................................................................6-148  
6.36 Key Status Programming............................................................................................6-153  
6.37 Cash Tender Key Preset Amount Setting ...................................................................6-157  
6.38 Drawer Warning Time Setting.....................................................................................6-159  
6.39 Special Rounding Process Setting, 1-digit type...........................................................6-161  
6.40 Special Rounding Process Setting, 2-digit type...........................................................6-163  
6.41 Number of Receipt Print Buffer Line Setting ...............................................................6-166  
6.42 Serial No. Setting........................................................................................................6-168  
7. VERIFICATION OF PROGRAMMED DATA...............................................................7- 1  
CAUTION!  
1. This manual may not be copied in whole or in part without prior written permission of TOSHIBA TEC.  
2. The contents of this manual may be changed without notification.  
3. Please refer to your local Authorised Service representative with regard to any queries you may have in  
this manual.  
Copyright © 2005  
by TOSHIBA TEC CORPORATION  
All Rights Reserved  
570 Ohito, Izunokuni-shi, Shizuoka-ken, JAPAN  
1. INTRODUCTION  
EO3-11106  
1.1 Main Features  
1. INTRODUCTION  
This programming manual is provided for salespersons, field engineers, and other personal as supplementary  
manual for TOSHIBA TEC Electronic Cash Register MA-600 series.  
Reading through the MA-600 Owner’s Manual is recommended in order to thoroughly understand the  
descriptions in this manual.  
1.1  
Main Features  
This ECR adopts an LCD display (192 x 64 dots), which displays a maximum of 24 one-byte characters by 4  
lines.  
A PC is connectable to the ECR with USB connection.  
Files for up to 40 departments, 1000 PLUs, and 8 cashiers can be controlled.  
Consignment print feature is supported. (Immediately after performing the Department/PLU entry or finalizing  
a sale, the [CONSIGNMENT] key depression leads to an issuance of a receipt only for the entry or sale  
finalization just performed.)  
Key-in tone at the registering operation and error tone are selectable from High (standard setting), Low, and  
OFF.  
Key sticker printing feature is adopted.  
1.2  
Description of Model Number  
1.2.1 Terminal Model Number  
M A - 6 0 0 -  
-
-
- R  
RoHS Compliance  
Blank: Non-RoHS compliant model  
R:  
RoHS compliant model  
Destination Code  
(QP, GB, etc.)  
Drawer Type  
G: ESP drawer  
Keyboard Type  
Blank: Normal type keyboard  
F:  
Flat type keyboard  
Series  
2:  
QP type  
1- 1  
2. SPECIFICATIONS  
EO3-11106  
2. SPECIFICATIONS  
2. SPECIFICATIONS  
SIZE:  
410 mm (width) x 442 mm (depth) x 291 mm (height)  
(height including rubber feet)  
Height when the customer display is fully raised: 351 mm  
WEIGHT:  
Approximately 13.6Kg  
POWER REQUIREMENT:  
AC 220 V to AC 230 V ±10 %; 50/60 Hz ±10 % (QP model)  
AC 230 V ±10 %; 50/60 Hz ±10 % (GB model)  
AC 240 V ±10 %; 50/60 Hz ±10 % (AU model)  
(varies depending on the destination)  
POWER CONSUMPTION:  
BATTERY:  
Standby: 8.2 W (0.08 A), Operating: 35 W (0.23 A)  
Type ----------------------------------------------------- Lithium-vanadium battery  
Life ------------------------------------------------------- 5 years  
Back-up duration ------------------------------------- 1 month (in case of full charge)  
Charge method --------------------------------------- Inserting the power plug into an outlet  
Full charge time--------------------------------------- 48 hours or more  
AMBIENT TEMPERATURE:  
RELATIVE HUMIDITY:  
PRINTER:  
0°C to 40°C  
10 % to 90 % (No condensation)  
Model---------------------------------------------------- FTP-628MCL113 (FUJITSU)  
Number of stations----------------------------------- 2 stations (Receipt and Journal)  
Print method ------------------------------------------- Thermal direct printing  
Effective print width ---------------------------------- 48 mm  
Total Number of dots -------------------------------- 384 dots/line  
Dot pitch ------------------------------------------------ 0.125 mm (8 dots/mm)  
Dot size ------------------------------------------------- 0.125 mm x 0.12 mm  
Print speed--------------------------------------------- Max. 60 mm/sec.  
Printable digits ---------------------------------------- 32 one-byte characters per line  
Character components------------------------------ 12 (width) x 24 (height) dots  
Character spacing------------------------------------ 0 mm (No space)  
Line spacing ------------------------------------------- 3.6 mm/line  
Character size (one-byte character)------------- 1.5 mm (W) x 3.0 mm (H)  
Receipt cutting method ----------------------------- Manual cutting  
Size of store name logo----------------------------- 48 mm (W) x 15 mm (H)  
384 dots (W) x 120 dots (H)  
Paper loading method------------------------------- Drop-in method  
2- 1  
2. SPECIFICATIONS  
EO3-11106  
2. SPECIFICATIONS  
PAPER ROLL (RECEIPT and JOURNAL)  
Media---------------------------------------------------- Thermal roll paper  
Width ---------------------------------------------------- 58 +0/-1 mm  
Thickness----------------------------------------------- 0.060 mm to 0.075 mm  
Outside dimension ----------------------------------- 80 mm or less  
Recommended thermal paper -------------------- Only paper rolled onto a core is acceptable, however, the  
paper end should not be pasted to the core.  
Standard paper:  
TF60KS-E (Nippon Paper Industries)  
PD150R (Oji Paper Co., Ltd)  
High-sensitive paper:  
TF50KS-E4 (Nippon Paper Industries)  
Medium-term preserving paper:  
TP60KS-F1 (Nippon Paper Industries)  
P220VBB-1 (MITSUBISHI PAPER MILLS LIMITED)  
PD170R (Oji Paper Co., Ltd)  
Long-term preserving paper:  
TP50KJ-R (Nippon Paper Industries)  
PD152R (Oji Paper Co., Ltd)  
PD160R-N (Oji Paper Co., Ltd)  
AFP-235 (MITSUBISHI PAPER MILLS LIMITED)  
HA220AA (MITSUBISHI PAPER MILLS LIMITED)  
DISPLAY:  
Operator Display  
Upper row ---------------------------------------------- LCD display (192 x 64 dots)  
SET, X, Z BLIND mode: 24 one-byte characters x 4 lines  
REG, MGR, - mode: 16 one-byte characters x 2 lines  
Lower row ---------------------------------------------- 10-digit 7-segment fluorescent display  
Display colour: Amount portion (Green)  
DPT and X portions (Yellow)  
Conditions (Red and Green)  
Amount-------------------------------------------------- 8 digits (7 digits for registering)  
Department code:  
Repeat count:  
2 digits  
1 digit  
Customer Display  
Lower row ---------------------------------------------- 7-digit 7-segment fluorescent display  
Display colour: Amount portion (Green)  
Conditions (Red and Green)  
Amount-------------------------------------------------- 7 digits  
KEYBOARD:  
Number of keys --------------------------------------- Ordinary type keyboard: max. 66 keys  
Flat type keyboard: max.106 keys  
Mode Lock --------------------------------------------- 8 positions  
DRAWER:  
The size of the drawer and the specifications of the money case vary depending on the individual product  
standard.  
Drawer-open detector ------------------------------- Provided  
2- 2  
3. CAPACITIES  
EO3-11106  
3.1 Indexing Capacities  
3. CAPACITIES  
3.1  
Indexing Capacities  
Input Item  
Digits  
Remarks  
Amount  
7
6
Quantity in Multiplication  
Unit Price in Multiplication  
Tender Media Keys  
Non-add Number  
Percent Rate  
3 integer digits + 3 decimal digits (0.001 to 999.999)  
6
8
18  
5
2 integer digits + 3 decimal digits (0.001 to 99.999%)  
2 integer digits + 2 decimal digits (0.01 to 99.99%)  
VAT Rate  
4
PLU Code  
4
2-digit cashier’s own secret code (01 to 99) + 2-digit manager-  
Cashier Code  
4
assign code (01 to 08)  
1 to 30  
Salesperson Code  
Department Code  
Group Code  
2
2
2
1 to 40  
1 to 15  
3- 1  
3. CAPACITIES  
EO3-11106  
3.2 Basic Memory Capacities  
3.2  
Basic Memory Capacities  
(NOTE: For Item Count below, “6 + 2 digits” means that it has 6 integer digits and 2 decimal digits.)  
Group Memory (Group Name: 12 characters; max. 15 groups)  
Memory Type  
Counter or Total  
Digits  
6 + 2  
10  
Item Count  
Amount  
Daily Memory  
Item Count  
Amount  
6 + 2  
10  
Group Total  
Item Count  
Amount  
6 + 2  
10  
GT Memory  
Item Count  
Amount  
6 + 2  
10  
Group Total  
Department Memory (Department Name: 16 characters; max. 40 departments)  
Memory Type Counter or Total  
Customer Count  
Digits  
6
Daily Memory  
Item Count  
Amount  
6 + 2  
10  
Customer Count  
Item Count  
Amount  
6
GT Memory  
6 + 2  
10  
PLU Memory (PLU Name: 16 characters; max. 1000 PLUs)  
Memory Type  
Counter or Total  
Digits  
6 + 2  
10  
Item Count  
Amount  
Daily Memory  
Hourly Range Memory (max. 24 hour ranges)  
Memory Type  
Counter or Total  
Digits  
6
Customer Count  
Item Count  
Amount  
Daily Memory  
6 + 2  
10  
Salesperson Memory (Salesperson Name: 12 characters; max. 30 salespersons)  
Memory Type Counter or Total  
Item Count  
Digits  
6 + 2  
10  
Gross Sale  
Net Sale with Tax  
Return  
Amount  
Item Count  
Amount  
6 + 2  
10  
Daily Memory  
Item Count  
Amount  
6 + 2  
10  
3- 2  
3. CAPACITIES  
EO3-11106  
3.3 Financial Memory  
3.3  
Financial Memory  
Daily  
Counter  
GT  
Counter  
Type  
Name of Total/Counter  
Remarks  
Total  
Digits  
Counter  
Digits  
Total  
Digits  
Digits  
GT (Grand Total)  
16  
16  
16  
10  
8 x 10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
(16)  
(16)  
(16)  
10  
Non-resettable  
NET GT (All-media Sales GT)  
NEG GT  
Non-resettable  
Non-resettable  
GS (Gross Sale)  
Tax 1 to Tax 8  
Tax Total  
ITEM  
6 + 2  
6 + 2  
8 x 10  
10  
Net Sale with Tax  
%+ (% I)  
ITEM  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ITEM  
6 + 2  
6 + 2  
10  
6
6
6
6
10  
%- (% II)  
10  
Vender Coupon  
Amount Discount  
Negative Departments Total  
Special Rounding  
All-media Sales  
Cash Sales  
6
6
10  
6
6
10  
6 + 2  
6 + 2  
10  
10  
CUS  
CUS  
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10  
10  
Cheque Sales  
Credit Sales  
CUS  
10  
CUS  
10  
Misc. Media Sales  
Media-Coupon Sales  
Credit 1 Sales  
Credit 2 Sales  
Credit 3 Sales  
Credit 4 Sales  
Credit 5 Sales  
Received-on Account  
Paid-Out  
CUS  
10  
CUS  
10  
CUS  
10  
CUS  
10  
CUS  
10  
CUS  
10  
CUS  
10  
ENTRY  
ENTRY  
10  
10  
Cash-in-drawer  
Cash-in-drawer  
(Foreign Currency 1)  
Cash-in-drawer  
(Foreign Currency 2)  
Cash-in-drawer  
(Foreign Currency 3)  
Cash-in-drawer  
(Foreign Currency 4)  
Cash-in-drawer  
(Foreign Currency 5)  
10  
10  
10  
10  
10  
-- continued on the next page --  
3- 3  
3. CAPACITIES  
EO3-11106  
3.3 Financial Memory  
Financial Memory: (continued)  
Daily  
Counter  
GT  
Counter  
Type  
Name of Total/Counter  
Remarks  
Total  
Digits  
Counter  
Digits  
Total  
Digits  
Digits  
Cheque-in-drawer  
ENTRY  
ENTRY  
6
10  
10  
Cheque-in-drawer  
(Foreign Currency 1)  
Cheque -in-drawer  
(Foreign Currency 2)  
Cheque -in-drawer  
(Foreign Currency 3)  
Cheque -in-drawer  
(Foreign Currency 4)  
Cheque -in-drawer  
(Foreign Currency 5)  
6
6
6
6
ENTRY  
ENTRY  
ENTRY  
10  
10  
10  
ENTRY  
ENTRY  
ENTRY  
6
6
6
10  
10  
10  
Credit-in-drawer  
Credit-in-drawer  
(Foreign Currency 1)  
Credit-in-drawer  
(Foreign Currency 2)  
Credit-in-drawer  
(Foreign Currency 3)  
Credit-in-drawer  
(Foreign Currency 4)  
Credit-in-drawer  
(Foreign Currency 5)  
ENTRY  
ENTRY  
ENTRY  
6
6
6
10  
10  
10  
ENTRY  
ENTRY  
ENTRY  
6
6
6
10  
10  
10  
Misc. Media-in-drawer  
Misc. Media-in-drawer  
(Foreign Currency 1)  
Misc. Media -in-drawer  
(Foreign Currency 2)  
Misc. Media -in-drawer  
(Foreign Currency 3)  
Misc. Media -in-drawer  
(Foreign Currency 4)  
Misc. Media -in-drawer  
(Foreign Currency 5)  
ENTRY  
ENTRY  
ENTRY  
6
6
6
10  
10  
10  
ENTRY  
ENTRY  
ENTRY  
6
6
6
10  
10  
10  
Media-Coupon-in-drawer  
Media-Coupon-in-drawer  
(Foreign Currency 1)  
Media-Coupon-in-drawer  
(Foreign Currency 2)  
Media-Coupon-in-drawer  
(Foreign Currency 3)  
Media-Coupon-in-drawer  
(Foreign Currency 4)  
Media-Coupon-in-drawer  
(Foreign Currency 5)  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
6
6
6
6
10  
10  
10  
10  
Credit 1-in-drawer  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
6
6
6
6
6
10  
10  
10  
10  
10  
10  
10  
Credit 2-in-drawer  
Credit 3-in-drawer  
Credit 4-in-drawer  
Credit 5-in-drawer  
Cash-in-drawer Difference  
Cheque-in-drawer Difference  
at Money Declaration  
at Money Declaration  
-- continued on the next page --  
3- 4  
3. CAPACITIES  
EO3-11106  
3.3 Financial Memory  
Financial Memory: (continued)  
Daily  
Counter  
GT  
Counter  
Type  
Name of Total/Counter  
Remarks  
Total  
Digits  
Counter  
Digits  
Total  
Digits  
Digits  
Credit-in-drawer Difference  
Misc. Media-in-drawer Difference  
Media-Coupon-in-drawer Difference  
Credit 1-in-drawer Difference  
Credit 2-in-drawer Difference  
Credit 3-in-drawer Difference  
Credit 4-in-drawer Difference  
Credit 5-in-drawer Difference  
Item Correct  
10  
10  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
Item Correct on DP+/PLU+  
Void on DP+/PLU+  
10  
10  
10  
10  
10  
10  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ITEM  
6
10  
6
10  
10  
Void  
6
10  
6
Misc. Void  
6
10  
6
10  
Item Correct on others  
All Void  
6
10  
6
10  
Store Coupon  
6
6 + 2  
6
10  
6
6 + 2  
6
10  
Returned Merchandise  
Negative Mode ( - ) Total  
%- on Line Items  
ITEM  
10  
10  
ENTRY  
ENTRY  
ENTRY  
10  
10  
6
10  
6
10  
Amount Discount on Line Items  
Transfer Balance GT  
Transfer + GT  
6
10  
6
10  
10  
(10)  
(10)  
(10)  
10  
Non-resettable  
Non-resettable  
Non-resettable  
10  
Transfer - GT  
10  
Transfer + Daily  
10  
Transfer - Daily  
10  
10  
Previous Balance  
CUS  
6
10  
6
10  
Previous Balance R/A  
Previous Balance PO  
Taxable Total 1 to 8  
VAT 1 to 8  
10  
10  
Payments made for PB  
10  
10  
PB refunded to customers  
8 x 10  
8 x 10  
10  
8 x 10  
8 x 10  
10  
VAT Total  
Net Sale without Tax  
Tax-exempted Customer  
10  
10  
CUS  
6
6
VAT 1 to 8 Exempt  
Net Sale Item Count per  
Customer  
8 x 10  
10  
8 x 10  
10  
ITEM  
6 + 2  
6 + 2  
All-media Sales per Cus.  
No-sale Counter  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
6
6
6
6
Clear Key Counter  
Consignment Key Counter  
Validation Counter  
3- 5  
3. CAPACITIES  
EO3-11106  
3.4 Cashier Memory  
3.4  
Cashier Memory  
Daily  
Counter  
GT  
Counter  
Type  
Name of Total/Counter  
Remarks  
Total  
Digits  
Counter  
Digits  
Total  
Digits  
Digits  
GS (Gross Sale)  
Net Sale with Tax  
%+ (% I)  
ITEM  
ITEM  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ITEM  
CUS  
6 + 2  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
6 + 2  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
6 + 2  
6 + 2  
6
6
6
6
%- (% II)  
Vender Coupon  
Amount Discount  
Negative Departments Total  
All-media Sales  
Cash Sales  
6
6
6
6
6 + 2  
6
6 + 2  
6
CUS  
6
6
Cheque Sales  
Credit Sales  
CUS  
6
6
CUS  
6
6
Misc. Media Sales  
Media-Coupon Sales  
Credit 1 Sales  
Credit 2 Sales  
Credit 3 Sales  
Credit 4 Sales  
Credit 5 Sales  
Received-on Account  
Paid-Out  
CUS  
6
6
CUS  
6
6
CUS  
6
6
CUS  
6
6
CUS  
6
6
CUS  
6
6
CUS  
6
6
ENTRY  
ENTRY  
6
6
6
6
Cash-in-drawer  
Cash-in-drawer  
(Foreign Currency 1)  
Cash-in-drawer  
(Foreign Currency 2)  
Cash-in-drawer  
(Foreign Currency 3)  
Cash-in-drawer  
(Foreign Currency 4)  
Cash-in-drawer  
(Foreign Currency 5)  
10  
10  
10  
10  
10  
10  
10  
Cheque-in-drawer  
ENTRY  
ENTRY  
6
6
Cheque-in-drawer  
(Foreign Currency 1)  
Cheque -in-drawer  
(Foreign Currency 2)  
Cheque -in-drawer  
(Foreign Currency 3)  
Cheque -in-drawer  
(Foreign Currency 4)  
Cheque -in-drawer  
(Foreign Currency 5)  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
6
6
6
6
10  
10  
10  
10  
-- continued on the next page --  
3- 6  
3. CAPACITIES  
EO3-11106  
3.4 Cashier Memory  
Cashier Memory: (continued)  
Daily  
Counter  
GT  
Counter  
Type  
Name of Total/Counter  
Remarks  
Total  
Digits  
Counter  
Digits  
Total  
Digits  
Digits  
Credit-in-drawer  
Credit-in-drawer  
(Foreign Currency 1)  
Credit-in-drawer  
(Foreign Currency 2)  
Credit-in-drawer  
(Foreign Currency 3)  
Credit-in-drawer  
(Foreign Currency 4)  
Credit-in-drawer  
ENTRY  
ENTRY  
6
10  
10  
6
6
6
6
ENTRY  
ENTRY  
ENTRY  
10  
10  
10  
ENTRY  
ENTRY  
ENTRY  
6
6
6
10  
10  
10  
(Foreign Currency 5)  
Misc. Media-in-drawer  
Misc. Media-in-drawer  
(Foreign Currency 1)  
Misc. Media -in-drawer  
(Foreign Currency 2)  
Misc. Media -in-drawer  
(Foreign Currency 3)  
Misc. Media -in-drawer  
(Foreign Currency 4)  
Misc. Media -in-drawer  
(Foreign Currency 5)  
ENTRY  
ENTRY  
ENTRY  
6
6
6
10  
10  
10  
ENTRY  
ENTRY  
ENTRY  
6
6
6
10  
10  
10  
Media-Coupon-in-drawer  
Media-Coupon-in-drawer  
(Foreign Currency 1)  
Media-Coupon-in-drawer  
(Foreign Currency 2)  
Media-Coupon-in-drawer  
(Foreign Currency 3)  
Media-Coupon-in-drawer  
(Foreign Currency 4)  
Media-Coupon-in-drawer  
(Foreign Currency 5)  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
6
6
6
6
10  
10  
10  
10  
Credit 1-in-drawer  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
6
6
6
6
6
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
Credit 2-in-drawer  
Credit 3-in-drawer  
Credit 4-in-drawer  
Credit 5-in-drawer  
Cash-in-drawer Difference  
Cheque-in-drawer Difference  
Credit-in-drawer Difference  
Misc. Media-in-drawer Difference  
Media-Coupon-in-drawer Difference  
Credit 1-in-drawer Difference  
Credit 2-in-drawer Difference  
Credit 3-in-drawer Difference  
Credit 4-in-drawer Difference  
Credit 5-in-drawer Difference  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
at Money Declaration  
-- continued on the next page --  
3- 7  
3. CAPACITIES  
EO3-11106  
3.5 Others  
Cashier Memory: (continued)  
Daily  
Counter  
GT  
Counter  
Type  
Name of Total/Counter  
Remarks  
Total  
Digits  
Counter  
Digits  
Total  
Digits  
Digits  
Item Correct  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ITEM  
6
10  
10  
10  
10  
10  
10  
6
10  
10  
10  
10  
10  
10  
Item Correct on DP+/PLU+  
Void on DP+/PLU+  
Void  
6
6
6
Misc. Void  
6
Item Correct on others  
All Void  
6
6
Returned Merchandise  
Negative Mode ( - ) Total  
No-sale Counter  
Clear Key Counter  
Consignment Key Counter  
6 + 2  
6 + 2  
6
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
6
6
6
6
6
6
4
4
Validation Counter  
Money Declaration Counter  
Read Report Counter  
Reset Report Counter  
3.5  
Others  
Daily  
Counter  
Digits  
GT  
Counter  
Type  
Name of Total/Counter  
Remarks  
Total  
Digits  
Counter  
Digits  
Total  
Digits  
Hourly Range Reset Counter  
PLU Reset Counter  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
ENTRY  
4
4
4
4
4
4
4
4
4
4
Department Reset Counter  
Financial Read Counter  
Financial Reset Counter  
Salesperson Reset Counter  
3- 8  
3. CAPACITIES  
EO3-11106  
3.6 Memory Balance  
3.6  
Memory Balance  
1. GT (Grand Total) = Sum of Daily GS (Gross Sale)  
2. NET GT  
3. NEG GT  
= Sum of Daily Net Sales  
= GT – NET GT  
4. GS (Gross Sale) = (Sum of Positive Depts) + (Sum of Add-on Taxes) NOTE 1  
5. Net Sale  
= GS – (Sum of Negative Depts) + (%+) – (%-) – (Vender Coupon)  
– (Amount Discount) + (Special Rounding Fraction) NOTE 2  
= (Cash Sales) + (Sum of all other media sales) + (Previous Balance Sales)  
= (Sum of Hourly Sales)… If Financial Reset Report and Hourly Range Reset Report are taken at the  
same time.  
6. Negative Mode Total = (Net Sale + Received-on-Account + Paid-Out ) in Negative Mode  
7. Net Sale without Tax (N.NS)  
= (Net Sale) – (Sum of VATs)…applicable only when the VAT feature is selected  
8. Net Sale Item Count per Customer = (Item Count of Net Sale) ÷ (Customer Count of All-media Sales)  
All-media Sales per Customer = (Amount of All-media Sales) ÷ (Customer Count of All-media Sales)  
NOTES: 1. Applicable only when the Add-on Tax feature is selected.  
2. Special Rounding Fraction amounts for Received-on-Account and Paid Out transactions are not  
correctly processed into the memory.  
3- 9  
4. SYSTEM START-UP PROCEDURE  
EO3-11106  
4. SYSTEM START-UP PROCEDURE  
4. SYSTEM START-UP PROCEDURE  
Case 1: To start-up using the MA-600 terminal only  
RAM Clear (Chapter 5)  
All the programming operations required  
for the terminal (Chapter 6)  
Case 2: To start-up by installing programming data from the PC  
CAUTION!  
< Precautions for connection to PC >  
1. The USB cable should be connected to the ECR each time a PC sends/receives data to/from the ECR.  
If the USB cable is kept connected to the ECR for a long period of time, data transfer may not be  
performed properly.  
2. When the ECR is connected to a PC with the USB cable, be sure to turn on the ECR in any mode other  
than BLIND mode. Otherwise, the ECR may not start.  
RAM Clear (Chapter 5)  
Perform this setting only for selecting  
any other than the default value.  
PC Transmission Information Setting  
(See the next page.)  
Turn off the ECR.  
Connect a PC to the ECR via the USB  
cable.  
Turn on the ECR in any mode other than  
BLIND mode.  
For details, refer to the MA-600 Series  
PC Programming Tool Manual.  
DLL (Down Line Loading) the data  
programmed on the PC to the terminal.  
4- 1  
4. SYSTEM START-UP PROCEDURE  
EO3-11106  
4. SYSTEM START-UP PROCEDURE  
PC Transmission Information Setting  
Data transmission information setting with a PC connection is performed here.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: BLIND  
68 [X]  
1 [ST]  
2 [ST]  
3 [ST]  
| POL Watch Timer | [#]  
Max. 2 digits: 0 to 99  
(Standard: 20 sec.)  
| Response Watch Timer | [#]  
Max. 2 digits: 0 to 99  
(Standard: 20 sec.)  
| Transmission Delay Timer | [#]  
Max. 2 digits: 0 to 99  
(1 = 20 ms)  
(Standard: 3 = 60 ms)  
4 [ST]  
| Transmission Delay Timer 2 | [#]  
2 digits: 15 to 99  
(1 = 20 ms)  
(Standard: 25 = 500 ms)  
[AT/TL]  
NOTE: When performing the key operation of 68 [X] [AT/TL], a receipt containing the currently programmed  
values is issued.  
Example) To set the following values;  
POL Watch Timer:  
Response Watch Timer:  
Transmission Delay Timer:  
30 (sec)  
20 (sec)  
4 (80 ms)  
TEC STORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
Transmission Delay Timer 2: 25 (500 ms)  
Key Operation: Mode Lock: BLIND, enter 68, depress [X].  
1 [ST] 30 [#] POL Watch Timer  
31-10-2005 MON #3001  
PC COM.  
2 [ST] 20 [#] Response Watch Timer  
3 [ST] 4 [#] Transmission Delay Timer  
4 [ST] 25 [#] Transmission Delay Timer 2  
[AT/TL] To complete this setting  
#1  
#2  
#3  
#4  
30  
20  
4
25  
0077 16:50TM  
4- 2  
5. RAM CLEAR, DATA CLEAR, STATUS CLEAR  
EO3-11106  
5.1 RAM Clear  
5. RAM CLEAR, DATA CLEAR, STATUS CLEAR  
5.1  
RAM Clear  
CAUTION!  
This clear operation deletes all programmed data and sales data stored in the memory of the  
ECR. (i.e., the ECR goes back to initial status.)  
If the ECR becomes completely inoperative due to battery discharge or malfunction of the program memory, the  
RAM Clear operation must be carried out. When the RAM Clear is operated, all memory stored in the RAM will  
be cleared. (i.e., the programmed data and the sales data) In the clearing process, the designated zero-amount  
format is reset. Also “Initial Data” and “Initial Status” for respective programming items are automatically reset. A  
RAM clear is also necessary to determine the type of the ECR keyboard.  
1. Unplug the ECR to turn OFF.  
2. Use the S key to turn the Mode Lock to “BLIND” position.  
3. Plug in the ECR to turn ON, causing the following message is displayed.  
Please push [AT/TL]  
or please perform a  
RAM-C / DATA-C  
0
4. Depress the following Numeric keys according to the zero-suppress form and the type of keyboard installed.  
Keyboard Type  
(Destination Code)  
Flat Type (IT)  
Zero-suppress  
Form  
Numeric Keys  
[1] & [8]  
[1] & [9]  
[3] & [8]  
[3] & [9]  
. - - 0  
Ordinary Type (IT)  
Flat Type (QP)  
. - - 0  
0 . 0 0  
Ordinary Type (QP)  
0 . 0 0  
5. Depress the [AT/TL] key.  
6. A RAM Clear receipt is issued.  
31-10-2005 MON #0  
RAM-C  
0001 13:43TM  
NOTES: 1. When the RAM clear operation is performed, the condition “after all sales data reset” is obtained,  
just as “Status Clear” and “Data Clear”. Therefore, no Reset Report should be taken for starting  
any programming operation.  
2. On completion of Step 6, all the memory will be cleared, and at the same time the keyboard will  
automatically be programmed as specified in the “Standard Keyboard” (refer to the “SFKC”  
programming operation later described).  
3. After a RAM Clear, the Standard Program Data for FINANCIAL REPORT ITEM NAME and PRINT  
LINE ITEM NAME, etc. will also be set automatically.  
5- 1  
5. RAM CLEAR, DATA CLEAR, STATUS CLEAR  
EO3-11106  
5.2 DATA Clear  
5.2  
DATA Clear  
CAUTION!  
This clear operation deletes all sales data of any operation sequence stored in the memory of the  
ECR.  
Performing the DATA Clear operation will clear only the sales data accumulated in the memory of the ECR  
(report memory), however, the programmed data will not be cleared. By this operation, all sales data including  
non-resettable totals and counters, Reset Report Counts, and Receipt Consecutive No. are cleared.  
1. Unplug the ECR to turn OFF.  
2. Use the S key to turn the Mode Lock to “BLIND” position.  
3. Plug in the ECR to turn ON, causing the following message is displayed.  
Please push [AT/TL]  
or please perform a  
RAM-C / DATA-C  
0
4. Depress the following Numeric key.  
Zero-suppress  
Numeric Key  
Destination Code  
Form  
. - - 0  
[1]  
[3]  
IT  
QP  
0 . 0 0  
5. Depress the [AT/TL] key.  
6. A DATA Clear receipt is issued.  
31-10-2005 MON #0  
DATA-C  
0001 13:44TM  
NOTES: 1. When the DATA clear operation is performed, the condition “after all sales data reset” is obtained,  
just as “Status Clear”. Therefore, no Reset Report should be taken for starting any programming  
operation.  
2. None of PLU table, stock status, and stock memory are cleared.  
5- 2  
5. RAM CLEAR, DATA CLEAR, STATUS CLEAR  
EO3-11106  
5.3 STATUS Clear  
5.3  
STATUS Clear  
Performing the STATUS Clear operation will clear an error and the key locked condition, however, the sales data  
and the programmed data will not be cleared by this operation. When the STATUS Clear is operated to clear a  
key locked condition during sale, the sale item data that has already been entered for the current sale will be  
cleared.  
The STATUS Clear operation obtains the condition “after all sales data reset” which is required for some  
programming operations, but this operation will not affect any sales data. This condition is obtained by taking  
reset reports. In case you do not want to reset the sales data such as in business hours, this function is effective.  
Depending on the programming item, sales data should be reset instead of STATUS Clear to keep consistency  
between programmed data and sales data.  
The STATUS Clear can be performed in 2 methods shown below.  
< Method 1 >  
1. Unplug the ECR to turn OFF.  
2. Use the S key to turn the Mode Lock to “BLIND” position.  
3. Plug in the ECR to turn ON, causing the following message is displayed.  
Please push [AT/TL]  
or please perform a  
RAM-C / DATA-C  
0
4. Depress the [AT/TL] key.  
5. A STATUS Clear receipt is issued.  
< Method 2 >  
1. Turn the Mode Lock to “SET” position.  
2. Depress the [9] key (Numeric key) then the [ST] key.  
3. A STATUS Clear receipt is issued.  
31-10-2005 MON #0  
STATUS-C  
0002 13:45TM  
5- 3  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6. TERMINAL FILE PROGRAMMING  
6. TERMINAL FILE PROGRAMMING  
Table of Terminal File Programming Operations  
Condition  
(NOTE)  
Mode Lock  
Page  
Operation  
Position  
Instructions for Programming  
Character Entries  
---  
---  
---  
6-2  
6-7  
---  
---  
Condition Required for Programming Operations  
SFKC (Selective Function Key Code) Programming  
---  
6-13  
6-14  
All Resets  
BLIND  
BLIND  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
System Option Programming  
FZ  
6-18  
Commercial Message Programming  
Footer Message Programming  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime/CZ  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
6-49  
6-52  
6-55  
6-59  
6-61  
6-63  
6-66  
6-68  
6-71  
6-77  
6-83  
6-87  
6-93  
Store Name Message Programming  
Department Name Programming  
Department Group Name Programming  
Cashier Name and Status Programming  
PLU Name Programming  
Salesperson Name Programming  
Financial Report Item Name Programming  
Print Line Item Name Programming  
Display Item Name Programming  
Error Item Name Programming  
Read/Reset Report Name Programming  
Anytime/DZ, DGZ, PZ,  
PGZ  
Department Table Programming  
SET  
6-98  
Department Preset Price Setting or Changing  
Department Listing Capacity (LC) Programming  
Key Sticker Printing  
Anytime  
Anytime  
Anytime  
Anytime/PZ  
Anytime  
Anytime  
Anytime  
FZ  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
SET  
6-104  
6-106  
6-109  
6-113  
6-120  
6-123  
6-128  
6-130  
6-132  
6-135  
6-137  
6-138  
6-140  
6-142  
6-146  
6-148  
6-153  
6-157  
6-159  
6-161  
6-163  
6-166  
6-168  
PLU Table Programming  
PLU Preset Price Setting or Changing  
PLU Preset-Code Key Setting  
%+ and %- Preset Rate Setting  
VAT or Add-on Tax Rate Setting  
Foreign Currency Exchange Rate Setting  
Negative Amount Key Limit Amount Setting  
Time Setting or Adjustment  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
HZ  
Date Setting or Adjustment  
Store/Register No. Setting  
Hourly Range Table Setting  
Tone Volume Setting  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
Anytime  
Report Item Print/Non-Print Setting  
Key Status Programming  
Cash Tender Key Preset Amount Setting  
Drawer Warning Time Setting  
Special Rounding Process Setting, 1-digit type  
Special Rounding Process Setting, 2-digit type  
Number of Receipt Print Buffer Line Setting  
Serial No. Setting  
NOTE: All Resets = All Daily and GT Resets  
Anytime = Any time outside a sale  
(No condition required)  
DGZ = After Department GT Reset  
DZ = After Department Daily Reset  
FZ = After Financial Daily Reset  
HZ = After Hourly Range Reset  
PGZ = After PLU GT Reset  
PZ = After PLU Reset  
CZ = After Cashier Reset  
6- 1  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.1 Instructions for Programming  
6.1  
Instructions for Programming  
On the MA-600 series adopting the LCD display, each programming operation is performed by selecting the  
corresponding menu item on the LCD display.  
The keyboard layout is automatically switched among three according to operation to be performed (ordinary  
registration, read/reset, programming) when the Mode Lock is turned to the corresponding position.  
Accordingly, in addition to the character code entry method, the character entries in programming operations are  
also performed directly through the ordinary type keyboard.  
6.1.1 SET Mode Menu  
When performing a programming operation, a desired programming item is selected from the menu which is  
shown on the LCD display. Programming menu tree is as shown below.  
1 MESSAGES  
1 COMMERCIAL MESSAGE  
4 RATE, LIMIT AMOUNT  
1 %- RATE (%-/%+)  
2 VAT/TAX RATE  
2 FOOTER MESSAGE  
3 STORE MESSAGE  
3 CUR EXCHANGE RATE  
4 DISC AMT LIMIT  
2 NAMES  
1 DP KEY NAME  
2 DP GROUP NAME  
3 CASHIER NAME  
5 BASIC  
1 TIME  
4 PLU (ITM NO.) NAME  
5 SALESPERSON NAME  
6 FINANCIAL ITM NAME  
7 PRINT ITEM NAME  
8 DISPLAY ITEM NAME  
9 ERROR ITEM NAME  
0 X/Z REPORT NAME  
2 DATE  
3 REGISTER NO.  
4 HOURLY RANGE  
5 KEY-IN TONE  
6 OTHER  
1 REPORT PRINT ITEM  
2 SYSTEM OPTION  
3 KEY FUNCTION  
4 CASH KEY AMOUNT  
5 DRW WARNING TIME  
6 ROUND TBL 1 DIGIT  
7 ROUND TBL 2 DIGIT  
8 RTC PRINT BUFFER  
9 SERIAL NO.  
3 DP/PLU  
1 DP  
1 DP SETTING  
2 UNIT PRICE  
3 DIGIT LIMIT (PRICE)  
4 KEY STICKER PRINT  
2 PLU  
1 PLU SETTING  
2 UNIT PRICE  
3 ASSIGN TO KEYBOARD  
4 DELETE (INDIV)  
5 DELETE (ALL)  
6- 2  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.1 Instructions for Programming  
6.1.2 Keyboard Layout Variations  
The keyboard layout is automatically switched among three according to operation to be performed (ordinary  
registration, read/reset, programming) when the Mode Lock is turned to the corresponding position.  
In this chapter, various programming operations are performed with the keyboard layout for programming.  
(1)  
Keyboard layout for ordinary registration (It is programmed as default setting.)  
Mode Lock Position:  
REG  
MGR  
Ordinary Type Keyboard  
VALI  
DATE  
LOG/  
RECEIPT  
RECIPT  
ISSUE  
SALES  
PERSON  
RF  
JF  
#
9
6
3
.
CUR  
R/A  
%-  
1
2
3
4
5
6
7
8
9
11  
12  
13  
14  
15  
ALL  
VOID  
RTN  
MDSE  
C
PO  
ITEM  
CORR  
NS  
7
4
1
0
8
5
PR  
OPEN  
X
VAT  
CRT  
MISC  
CPN  
LC  
OPEN  
AMT  
2
10  
CHK  
TEND  
PLU  
00  
ST  
AT/TL  
Flat Type Keyboard  
LOG/  
RECEIPT  
RECEIPT  
ISSUE  
RF  
JF  
R/A  
%-  
PO  
1
2
3
4
5
6
7
8
9
ALL  
VOID  
ITEM  
CORR  
RTN  
MDSE  
VOID  
#
AMT  
X
C
NS  
9
VAT CUR  
CRT  
10  
11  
12  
13  
14  
5
4
1
0
8
5
CHECK  
TEND  
6
2
3
ST  
PLU  
00  
AT/TL  
.
Department  
keys  
PLU Preset-code keys  
6- 3  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.1 Instructions for Programming  
(2)  
Keyboard layout for programming  
Mode Lock Position:  
SET  
BLIND  
Ordinary Type Keyboard  
History  
Del  
RF  
JF  
#
A
B
C
D
E
?
F
G
H
I
K
L
P
Q
R
S
T
U
V
ALL  
VOID  
C
Rtn  
Dbl  
A/a  
7
4
1
0
8
5
9
M
N
O
W
X
6
Enter  
2
3
J
Y
PLU  
00  
End  
Z
.
Flat Type Keyboard  
1
!
2
@
Σ
3
#
4
$
5
%
é
6
&
ê
7
*
8
(
9
)
0
:
LOG  
RF  
JF  
ALL  
VOID  
A/a  
#
Dbl  
Del  
History  
Enter  
β
ú
á
â
£
U
H
B
è
Ø
I
ç
Œ
-
C
Rtn  
Ä
Q
?
Ö
W
A
Ü
E
S
Z
Å
R
D
X
Æ
T
Ñ
Y
G
V
+
O
K
M
?
7
4
1
0
8
5
9
6
3
.
P
L
,
X
F
J
N
2
ST  
End  
PLU  
SP  
C
00  
6- 4  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.1 Instructions for Programming  
(3)  
Keyboard layout for Read/Reset  
Mode Lock Position:  
X
Z
Ordinary Type Keyboard  
RF  
JF  
#
9
6
3
.
C
Rtn  
X
7
4
1
0
8
5
Enter  
2
PLU  
00  
ST  
AT/TL  
Flat Type Keyboard  
RF  
JF  
Enter  
#
C
Rtn  
7
4
1
0
8
5
9
6
3
.
X
2
ST  
AT/TL  
PLU  
00  
6- 5  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.1 Instructions for Programming  
6.1.2 Basic Key Functions  
1. The following are main keys and their functions to be used in programming operations.  
(1) Keys for selecting items on the menu screen  
Key  
[ ]  
Function  
This key is used for moving the cursor upward.  
[ ]  
This key is used for moving the cursor downward.  
[ ]  
[ ]  
[Enter]  
[Rtn]  
[?]  
This key is used for moving the cursor leftward.  
This key is used for moving the cursor rightward.  
This key is used for selecting a desired item after moving the cursor.  
This key is used for returning the display to the previous screen.  
While ? is shown on the upper-right corner of the LCD display screen, the [?] key  
depression results in that a guidance message corresponding to the current operation  
appears on the LCD display. When depressing the [?] key again, the display will  
return to the previous screen.  
(2) Keys for character entries  
Key  
Function  
[ ]  
[C]  
[Dbl]  
This key is used for entering a one-byte space.  
This key is used for deleting all the entered characters together.  
This key is used for switching character mode between “one-byte character” and “two-  
byte character” alternately.  
[A/a]  
This key is used for switching between “capital letter” and “small letter” alternately.  
The key is effective when entering characters A to Z through the programming  
keyboard or PK-2 keyboard (hardware option).  
[Del]  
[#]  
This key is used for deleting a character.  
In the character code entry method, entering a character code then depressing this  
key results in that the corresponding character is entered.  
[History]  
This key is used for performing character entries with the name previously entered.  
(3) Keys for programming  
Key  
Function  
This key is used for selecting a desired item.  
This key is used for selecting a desired item.  
This key is used for cancelling an operation just performed.  
This key is used for entering a desired item.  
This key is used for returning the display to the previous screen.  
While ? is shown on the upper-right corner of the LCD display screen, the [?] key  
depression results in that a guidance message corresponding to the current operation  
appears on the LCD display. When depressing the [?] key again, the display will  
return to the previous screen.  
[ ]  
[ ]  
[C]  
[Enter]  
[Rtn]  
[?]  
[End]  
[PLU]  
This key is used for ending the current programming operation.  
This key is used for the PLU programming.  
2. Functions of the [C] key  
When an entered program data is already printed, the [C] key cannot clear if any longer. To correct the  
data, re-enter it.  
Before the entered data is printed, the data may be cleared by the [C] key (except in the SFKC  
Programming Operation).  
6- 6  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.2 Character Entries  
3. To clarify the operation flow, definitions of keys of the ECR keyboard are as shown below.  
|
[
| --------- Selective numeric value which is entered through the Numeric keys.  
]---------- Depression of the function key.  
xxxx------------- Fixed numeric value which is entered through the Numeric keys.  
Fixed  
4. Table of key names in SET and REG modes  
The keyboard layout for programming is adopted in SET mode.  
The following table shows key names in SET mode and corresponding ones in REG mode.  
Key name in REG mode  
(Normal type keyboard)  
[LOG/RECIEPT]  
[RTN MDSE]  
[NS]  
Key name in REG mode  
(Flat type keyboard)  
[R/A]  
Key name in SET mode  
[]  
[]  
[]  
[PO]  
[%-]  
[]  
[PR OPEN]  
[LC OPEN]  
[ITEM CORR]  
[ST]  
[ - ]  
[CUR]  
[VAT]  
[AMT]  
[Enter]  
[Rtn]  
[?]  
[C]  
[C]  
[C]  
[Dbl]  
[A/a]  
[Del]  
[#]  
[X]  
[AMT]  
[VALI DATE]  
[#]  
[VOID]  
[ITEM CORR]  
[RTN MDSE]  
[#]  
[History]  
[End]  
[PLU]  
[RECEIPT ISSUE]  
[AT/TL]  
[NS]  
[AT/TL]  
[PLU]  
[PLU]  
6.2  
Character Entries  
There are two methods of character settings for various names and messages:  
CHARACTER CODE ENTRY Method and DIRECT CHARACTER ENTRY Method.  
CHARACTER CODE ENTRY Method  
This method is to set a character by entering a Character Code and depressing the [#] key. The method is  
operated only on the ECR keyboard (Ordinary Type or Flat Type).  
DIRECT CHARACTER ENTRY Method  
This method is to set a character by directly depressing the Character Keys on any of the following keyboard:  
ECR keyboard with the keyboard layout for programming  
PK-2 keyboard (PLU keyboard; hardware option)  
By using those character keys, the characters are directly entered. In this manual, sample operations are  
attached to most of the programming operations. And at name or message programming portions, characters  
except for numeric and special symbols are entered by the DIRECT CHARACTER ENTRY method.  
On the following pages, Character Code Tables under the CHARACTER CODE ENTRY Method and two  
different keyboards under the DIRECT CHARACTER ENTRY Method are shown. These pages are to be  
referred to, every time the “Character Entries” sequence is contained in various programming operations in  
this manual.  
Read through these pages at least once first, so that you may know the appropriate method of character  
entries using the ECR keyboard and/or option keyboard.  
6- 7  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.2 Character Entries  
6.2.1 Character Code Entry Method  
Character Code Table 1: Standard Characters  
Column Code  
2
3
4
5
6
7
8
9
10 11 12 13 14 15  
00 SP  
0
1
2
3
4
5
6
7
8
9
:
@
A
B
C
D
E
F
P
Q
R
S
T
U
V
W
X
Y
Z
[
`
a
b
c
d
e
f
p
q
r
á
é
í
Å
å
\
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
!
"
Row  
Code  
Ø
ø
#
$
%
&
'
s
t
ó
ú
â
ê
î
,
Æ
æ
Œ
œ
β
½
¼
Ì
Kg  
lb  
u
v
w
x
y
z
{
Ä
Ë
Ö
Ü
É
ä
ë
ï
G
H
I
g
h
i
(
ô
û
à
è
ì
)
¢
*
J
j
£
No  
X
+
,
;
K
L
k
l
Φ
÷
<
=
>
?
¥
|
V
U
-
M
N
O
]
m
n
o
}
ç
Ñ
ñ
.
^
¯
ö
ü
/
_
NOTE:  
Characters of those character codes 1007, 1206, 1207, 1211, 1500 through 1503, and 1506 through  
1514 cannot be printed on the slip printer.  
6- 8  
6. TERMINAL FILE PROGRAMMING  
Character Setting Operations  
EO3-11106  
6.2 Character Entries  
To set a one-byte character, enter the COL (column) code and then the ROW code, followed by the [#] key.  
ex.) To set “%”, enter 205 and depress the [#] key.  
To set “kg”, enter1508 and depress the [#] key.  
To set a space instead of a character, simply depress the [#] key without a prior entry, or enter 200 and  
depress the [#] key.  
To set two-byte characters, depress the [Dbl] key to declare the two-byte character entry, then enter a  
character code, followed by the [#] key. The [Dbl] key declaration is effective until this key is depressed again.  
ex.) To set “GROUP” all in two-byte characters:  
[Dbl] 407 [#]  
502 [#]  
415 [#]  
505 [#]  
500 [#]  
G
R
O
U
P
Two-byte character declaration  
ex.) To set “GROUP”, “G” in two bytes, and “ROUP” in one byte:  
[Dbl] 407 [#]  
[Dbl]  
502 [#]  
415 [#]  
505 [#]  
500 [#]  
G
R
O
U
P
Two-byte character  
Declaration  
Cancelling  
the declaration  
6- 9  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.2 Character Entries  
6.2.2 Direct Character Entry Method  
Using Keyboard (installed as the ECR Main Keyboard):  
-- Keyboard layout for programming --  
Ordinary Type Keyboard  
History  
Del  
RF  
JF  
#
A
B
C
D
E
?
F
G
H
I
K
L
P
Q
R
S
T
U
ALL  
VOID  
C
V
Rtn  
Dbl  
A/a  
7
4
1
0
8
5
9
M
N
O
W
6
X
Enter  
2
3
J
Y
PLU  
00  
End  
Dbl  
Z
.
Flat Type Keyboard  
LOG  
1
!
2
@
Σ
3
#
4
$
5
%
é
6
&
ê
7
*
8
(
9
)
0
:
RF  
JF  
A/a  
#
Del  
?
History  
Enter  
β
ú
á
â
£
U
H
B
è
Ø
I
ç
Œ
-
C
Rtn  
Ä
Q
?
Ö
W
A
Ü
E
S
Z
Å
R
D
X
Æ
T
Ñ
Y
G
V
+
O
K
M
7
4
1
0
8
5
9
6
3
.
P
L
,
X
F
J
N
2
ST  
End  
PLU  
SP  
C
00  
Character keys in programming  
Function keys in programming  
Character Keys: Simply depress the key to enter the character. (The [#] key should not follow.)  
Keys 1 to 0 are used for entering numeric characters 1 to 0.  
Function Keys: These are function keys to be used in programming operations.  
The numeric keys here are used for entering PLU Codes, etc. and numeric values as program  
data.  
6- 10  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.2 Character Entries  
Using PK-2 (PLU Keyboard; hardware option)  
The PK-2 keyboard is used for entering a required PLU code by simply depressing the code-preset key on this  
keyboard in REG or MGR mode. In addition, the PK-2 can be used for directly entering characters during the  
programming operations that require character settings such as STORE NAME/MESSAGE AND COMMERCIAL  
MESSAGE PROGRAMMING and DEPARTMENT NAME PROGRAMMING.  
The following shows the key indications of the PK-2 for the character setting purpose.  
Insert the template for this purpose between the film layers that cover the PK-2.  
Instead of entering a 3- or 4-digit character code and depressing the [#] key on the ECR keyboard, a simple  
depression of the appropriate key on the PK-2 will be the character entry.  
All the function keys such as [], [], [], [], [Enter] must be operated on the ECR side. Any characters not  
listed on the template may be entered by the CHARACTER CODE ENTRY method on the ECR keyboard. (The  
characters even listed on the template may be entered as well by that method.)  
The two-byte character declaration is the same as in the CHARACTER CODE ENTRY method.  
7
4
1
8
5
2
0
^
+
=
]
9
6
3
!
@
w
s
#
e
$
r
%
t
¢
y
&
u
*
i
(
o
l
)
p
"
q
a
z
~
_
-
d
f
g
h
j
k
x
c
v
R
F
V
b
n
m
U
J
'
Q
A
Z
W
S
X
E
D
C
T
G
B
Y
H
N
I
O
L
.
P
;
[
K
:
,
Space  
M
/
?
6- 11  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.2 Character Entries  
6.2.3 How to use the [History] key  
The [History] key is used for performing character entries with the name previously entered.  
Operation:  
[History]  
([])  
[Enter]  
1) The [History] key depression will let the most recently programmed name displayed on the LCD display.  
2) The [] key depression will let the second most recently programmed name displayed. (Up to 10  
programmed names will be displayed in reverse chronological order.)  
3) The [Enter] key depression will allow the name on the LCD display to be entered.  
Example of operation:  
When “A LUNCH” for PLU1 and “B LUNCH” for PLU2 are programmed in the PLU name programming.  
Key operation  
1 [PLU]  
[C]  
401 [#]  
[#]  
Description  
PLU No.1 setting is declared.  
The default setting displayed on the LCD display is deleted.  
The character A is entered.  
LCD display  
PLU0001  
A
A
A space is entered.  
412 [#]  
505 [#]  
414 [#]  
403 [#]  
408 [#]  
[ST]  
The character L is entered.  
The character U is entered.  
The character N is entered.  
The character C is entered.  
The character H is entered.  
The name of PLU No.1 is entered.  
PLU No.2 setting is declared.  
The default setting displayed on the LCD display is deleted.  
The name of PLU No. 1 just entered is called.  
The name of PLU No. 1 is entered.  
The character A of “A LUNCH” is deleted.  
The character B is entered instead of the deleted A.  
The name of PLU No.2 is entered.  
A L  
A LU  
A LUN  
A LUNC  
A LUNCH  
2 [PLU]  
[C]  
[History]  
[Enter]  
[Del]  
PLU0002  
A LUNCH  
A LUNCH  
LUNCH  
402 [#]  
[ST]  
B LUNCH  
6- 12  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.3 Condition Required for Programming Operations  
6.3  
Condition Required for Programming Operations  
“CONDITION” is given at the top of each programming operation. The ECR must satisfy this condition to perform  
programming operations.  
There are two types of conditions:  
“Any time outside a sale”  
It means that the programming operation is allowed when a sale is finalized before going into any other sale entry.  
“After------ reset”  
It means that the designated reset report must be taken before entering the programming operation.  
And an error will result if the operation is attempted without taking the report. However, the words “After ...  
Reset” do not necessarily mean “immediately after ...”.  
When the designated reset report has already been taken and then some operations are performed in the SET, X,  
or Z mode, the condition “After ... Reset” is still satisfied and the programming operation is still allowed.  
On the contrary, when the designated reset report has been taken but then some sales data relating to that  
report’s output data are entered in the REG, MGR, or - mode, the programming operation will no longer be  
allowed and the same reset report must be taken.  
Thus the condition “After ... Reset” indicates that all the sales data relating to the report data must be zero  
(except non-resettable memory data). Because of this “CONDITION” requirement, the report data will be  
protected from any inconsistencies of sales data entered in the period from a resetting of the report to another  
resetting of the same report next time.  
6- 13  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.4 SFKC (Selective Function Key Code) Programming  
6.4  
SFKC (Selective Function Key Code) Programming  
SFKC Programming is to determine the keyboard layout with the required keys. This operation must be  
performed first before any other programming operation. If the RAM Clear is performed prior to the SFKC  
programming, program only the keys that require changes from the SFKC in the Standard Keyboard which has  
been set by the RAM Clear operation automatically. (For the Standard Keyboard, see Page 6-17.)  
The following keys that are minimum requirements for programming and registering operations must be assigned  
to the keyboard no matter what any other keys may or may not be assigned:  
[C], [X], [ST], [AT/TL], [#], and Department Keys or [DP#]  
CONDITION  
OPERATION  
After all Z and GTZ reports, or after RAM Clear, DATA Clear, or STATUS Clear  
Mode Lock: BLIND  
76 [AT/TL]  
| SFKC |  
[KEY]  
[AT/TL]  
to read preset SFKC  
The key that requires the  
function of the SFKC  
Repeat  
1. Enter 76, and depress the key to be [AT/TL] (Cash Media key). This declares the SFKC Programming Start  
and at the same time sets the SFKC 76 on the key.  
From this step on, the depressed key will be [AT/TL].  
2. Enter the SFKC (see the SFKC table on the following pages), and depress the key that requires the key name  
of the SFKC. Repeat this step until all the necessary keys are set with their own SFKC’s. Each key on the  
keyboard must correspond to one SFKC, except for SFKC 96 (PLU Preset-code Keys). If in this step, a key is  
simply depressed without a prior SFKC entry, the SFKC that has been pre-programmed on that key is  
displayed at that Amount portion.  
3. Depress the [AT/TL] key (the key set as [AT/TL] in Step 1) to end the SFKC programming operation. The  
display now shows “0” at the Amount portion. A receipt is issued.  
NOTES:  
1. The entered SFKC is displayed at the Amount portion of the display.  
2. If a wrong code has been entered and the key has also been depressed (i.e. a wrong SFKC has been set on  
a key), enter the correct SFKC and depress the key.  
3. If “0” is entered as SFKC, the key will be dead and its memory will also be closed.  
76 [AT/TL]  
0
[KEY]  
[AT/TL]  
4. Each of the keys programmed in this step will have its memory (if any) opened automatically.  
5. The [C] key, if once set with SFKC 95, may be used to clear an error, but not to clear and SFKC entry. If  
any SFKC is entered and the [C] key is depressed, that SFKC will be set on the key that was once the [C]  
key.  
6. To designate the SFKC 100, operate the keys [1] [0] [0]. In this case, the [00] key is unavailable.  
7. When a key is opened here, the print status should be set to its memory in Report Item Print/Non-Print  
Setting.  
8. The [RF], [JF], [00], and [ . ] keys can also be programmed by the SFKC programming operation.  
9. If [RF] and [JF] are programmed on several keys, that with largest key location code is effective. The  
remaining [RF] and [JF] keys are ignored. (Only one them are operable each.)  
10. The location of the [AT/TL] key is fixed.  
6-14  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.4 SFKC (Selective Function Key Code) Programming  
SFKC Table  
SFKC  
Key Name  
Memory to be opened (REMARKS)  
0
1 to 40  
61  
Dead-key code  
Department Preset-code Keys 1 to 60  
RF (Receipt Feed)  
(used to close the key and memory)  
Respective Department memory  
No memory  
62  
JF (Journal Feed)  
No memory  
63  
00 (Double-zero)  
No memory  
64  
000 (Triple-zero)  
No memory  
65  
(Decimal Point)  
No Memory  
66  
67  
68  
VND CPN (Vender Coupon)  
STR CPN (Store Coupon)  
-- vacant --  
Vender Coupon  
Store Coupon  
69  
70  
- (Amount Discount)  
%+ (% I)  
Amount Discount  
% I  
71  
%- (% II)  
% II  
72  
73  
74  
RTN MDSE (Returned Merchandise)  
ITEM CORR (Item Correct)  
VOID (Void)  
Returned Merchandise  
Item Correct, Misc. Void  
Void, Misc. Void  
75  
ALL VOID (All Void)  
AT/TL (Cash Amount Tender/Total)  
-- Cash Media  
All Void  
Cash Sales, Cash-in-drawer,  
Cash-in-drawer Difference  
Check Sales, Check-in-drawer,  
Check-in-drawer Difference  
Credit Sales, Credit-in-drawer,  
Credit-in-drawer Difference  
Misc. Sales, Misc.-in-drawer,  
Misc.-in-drawer Difference  
Media-Coupon Sales, Media-Coupon-in-drawer  
Media-Coupon-in-drawer Difference  
Credit 1 Sales, Credit 1-in-drawer  
Credit 1-in-drawer Difference  
No memory  
Received-on-Account  
Paid Out  
No-sale Counter  
No memory  
No memory  
No memory  
Validation counter  
No memory  
76  
77  
78  
79  
80  
81  
CHK TND (Check Tender)  
CRT (Credit Total)  
MISC TEND (Miscellaneous Tender)  
CPN (Media Coupon)  
CREDIT 1 (Credit 1)  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
ST (Subtotal)  
R/A (Received-on-Account)  
PO (Paid-Out)  
NS (No-sale)  
PR OPEN (Preset Open)  
LC OPEN (Listing Capacity Open)  
OPEN (PR/LC Open)  
VALIDATE (Validation)  
# (Non-add Number)  
CONSIGNMENT  
Consignment counter  
(To open memory, each PLU program is further  
necessary; however, if this key is closed, the  
memory for all PLUs are closed.)  
No memory  
92  
PLU (Price-Look-Up)  
93  
94  
95  
X
RECEIPT ISSUE (Receipt Post-Issue)  
C (Clear)  
No memory  
Clear Key Counter  
96  
97  
98  
99  
PLU Preset-code keys  
TX1/M (Tax 1 Modifier)  
TX2/M (Tax 2 Modifier)  
-- vacant --  
No memory  
No memory  
No memory  
100  
101  
-- vacant --  
EX (Tax Exempt)  
PB+ (Previous Balance +; for Manual  
PB Entry Type)  
PB- (Previous Balance -; for Manual  
PB Entry Type)  
Exempt Customer, Exempt 1, 2, 3, 4  
Transfer, Previous Balance Sales, Previous  
Balance R/A, Previous Balance PO  
102  
103  
No memory  
-- Continued on next page --  
6-15  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.4 SFKC (Selective Function Key Code) Programming  
SFKC Table (continued)  
SFKC  
Key Name  
Memory to be opened (REMARKS)  
104  
105 to 107  
108  
TRF (Transfer)  
-- vacant --  
AMT (Amount)  
RPT (Repeat)  
No memory  
No memory  
No memory  
109  
110 to 115  
116  
117 to 120  
121  
-- vacant --  
TX3/M (Tax 3 Modifier)  
-- vacant --  
CUR 1 (Foreign Currency 1)  
CUR 2 (Foreign Currency 2)  
CUR 3 (Foreign Currency 3)  
CUR 4 (Foreign Currency 4)  
CUR 5 (Foreign Currency 5)  
No memory  
Foreign Currency 1-in-drawer  
Foreign Currency 2-in-drawer  
Foreign Currency 3-in-drawer  
Foreign Currency 4-in-drawer  
Foreign Currency 5-in-drawer  
Credit 2 Sales, Credit 2-in-drawer  
Credit 2-in-drawer Difference  
Credit 3 Sales, Credit 3-in-drawer  
Credit 3-in-drawer Difference  
Credit 4 Sales, Credit 4-in-drawer  
Credit 4-in-drawer Difference  
Credit 5 Sales, Credit 5-in-drawer  
Credit 5-in-drawer Difference  
No memory  
122  
123  
124  
125  
126  
127  
128  
129  
CREDIT 2 (Credit 2)  
CREDIT 3 (Credit 3)  
CREDIT 4 (Credit 4)  
CREDIT 5 (Credit 5)  
130  
131  
LOG/RECEIPT (Log/Receipt)  
LOG (Log)  
No memory  
132  
133  
SALES PERSON (Salesperson)  
-- vacant --  
No memory  
134  
135  
TX4/M (Tax 4 Modifier)  
DP# (Department No.)  
-- vacant --  
RECEIPT (Receipt)  
-- vacant --  
CLK1 (Cashier 1) to CLK8 (Cashier 8)  
-- vacant --  
VAT (VAT Print)  
-- vacant --  
No memory  
No memory  
136 to 138  
139  
140 to 142  
143 to 150  
151 to 162  
163  
No memory  
No memory  
No memory  
164  
165  
-- vacant --  
166  
167  
JP (Journal Print)  
-- vacant --  
No memory  
168  
169  
170  
1st PRICE  
2nd PRICE  
3rd PRICE  
No memory  
No memory  
No memory  
171 to 200  
201  
-- vacant --  
VAT DISPLAY  
No memory  
No memory  
No memory  
No memory  
No memory  
No memory  
No memory  
No memory  
202  
203  
204  
205  
206  
207  
208  
TX5/M (Tax 5 Modifier)  
TX6/M (Tax 6 Modifier)  
TX7/M (Tax 7 Modifier)  
TX8/M (Tax 8 Modifier)  
CASH1  
CASH2  
CASH3  
6-16  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.4 SFKC (Selective Function Key Code) Programming  
SFKC Receipt Sample  
31-10-2005 MON #0  
SFKC  
#054  
#043  
#044  
#045  
#047  
#046  
076  
102  
103  
104  
066  
067  
076  
102  
103  
104  
066  
067  
0003 13:05TM  
Standard Keyboard (auto-set by RAM Clear)  
Ordinary Type Keyboard  
LOG/  
RECEIPT  
VALI  
DATE  
RECEIPT  
ISSUE  
SALES  
RF  
JF  
#
CUR  
R/A  
%-  
PERSON  
1
6
7
8
9
11  
12  
13  
14  
15  
Del  
History  
RTN  
MDSE  
ALL  
VOID  
C
PO  
2
3
ITEM  
CORR  
NS  
7
4
1
0
8
5
9
-
Rtn  
PR  
OPEN  
X
Dbl  
6
VAT  
CRT  
MISC  
CPN  
4
5
LC  
OPEN  
AMT  
A/a  
2
3
10  
Enter  
ST  
AT/TL  
CHK  
TEND  
.
PLU  
00  
?
End  
Flat Type Keyboard  
LOG/  
RECEIPT  
RECIPT  
ISSUE  
RF  
JF  
R/A  
%-  
PO  
1
2
3
4
5
6
7
8
9
ALL  
VOID  
ITEM  
CORR  
RTN  
MDSE  
VOID  
#
AMT  
X
C
NS  
9
VAT  
CUR  
10  
11  
12  
13  
14  
7
4
1
0
8
5
CRT  
CHECK  
TEND  
6
2
3
ST  
PLU  
00  
AT/TL  
.
PLU Preset-code keys  
Department keys  
6-17  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
6.5  
System Option Programming  
This operation is used to set the ECR’s basic features and selective functions to meet the requirement of the  
market and your user.  
This programming operation is performed in SET mode or BLIND mode.  
In SET mode, you can select a desired menu item on the LCD display. Address No. 1 to Address No. 29 are  
programmable. In BLIND mode, you can directly enter a desired Address No. on the keyboard. All system  
options from Address No. 1 to Address No. 49 are programmable.  
CONDITION  
OPERATION  
After Financial Daily Reset  
For Dealer System Options:  
(Address No. 1 to No. 29)  
Mode Lock: SET  
For Dealer System Options:  
(Address No. 1 to No. 49)  
Mode Lock: BLIND  
Programming in SET mode  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] five times then [Enter].  
6 OTHER” is selected.  
or  
Depress [6].  
Depress [] then [Enter].  
2 SYSTEM OPTION” is selected.  
or  
Depress [2].  
Select a desired Address No.  
(Selectable from Address No. 1 to Address No.29.)  
with the [] or [] key.  
The Bit Numbers currently programmed are displayed on the 7-  
segment Numeric display.  
[Enter]  
Move the cursor on to a desired bit No.  
with the [] key.  
Every time the [] or [] key is depressed, N and Y are displayed  
alternately. N and Y indicate RESET and SET statuses,  
respectively.  
Choose bit status with the [] or []  
key.  
The selected Address No. setting is entered.  
The Bit Numbers with SET status are displayed on the 7-segment  
Numeric display.  
[Enter]  
[End]  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
6-18  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
Setting Example)  
To set Address No. 1 with the following requirements:  
(Refer to the Address No. 1 table on the subsequent page.)  
Bit No. 1: Time NON-PRINT (SET status)  
Bit No. 3: Subtotal NON-PRINT (SET status)  
Other bits will be selected to “RESET” status.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “6 OTHER”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
five times.  
Depress the [6] or [Enter] key.  
Depress the [] key.  
The cursor is moved on to “2 SYSTEM  
OPTION”.  
Depress the [2] or [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Address No. list is displayed. Select a  
desired Address No. with the [] or []  
key.  
In this example, Address No. 1  
(01NON-PRINT) is selected.  
For the selected Address No., the Bit  
Numbers currently programmed are  
displayed on the 7-segment Numeric display.  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
With the [Enter] key depression,  
Address No. 1 setting is displayed.  
(continued on the next page)  
6-19  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The status of Bit No.1 is turned from N to Y.  
N: RESET status  
Y: SET status  
Depress the [] key to select the  
status of Bit No. 1.  
The numeric value 1 indicating the Bit No.  
with SET status is displayed on the 7-  
segment Numeric display.  
Depress the [] key twice to move the  
cursor on to Bit No. 3 (B3ST).  
The status of Bit No.3 is turned from N to Y.  
N: RESET status  
Y: SET status  
Depress the [] key to select the  
status of Bit No. 3.  
The numeric value 13 indicating the Bit Nos.  
with SET status is displayed on the 7-  
segment Numeric display.  
The [Enter] key depression results in  
that the Address No. 1 setting is  
entered.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
Programming in BLIND mode  
Repeat for another Address No.  
18 [X]  
| Address No. | [ST]  
| Bit Nos for “SET” | [#]  
[AT/TL]  
Enter a maximum of eight-digit number composed of Bit Nos  
whose status must be selected to SET status in the Address.  
ex.) To set Bit No. 2 only ...................... Enter 2.  
To set Bits No. 2 and No. 3 ........... Enter 23.  
To set all the Bit Nos ..................... Enter 12345678.  
To reset all the Bit Nos .................. Enter 0.  
NOTES:  
1. Any Bit No. with the “-- vacant --” item will be ignored even if it is set.  
(However, even if set, it will not result in an error.)  
2. When a RAM Clear is completed, the status of each Bit No. is automatically set to the side marked with an  
asterisk in the STANDARD STATUS column of each SYSTEM OPTION TABLE shown on the following  
pages. Therefore, only the Bit status changes of the required Addresses may be entered according to your  
customer’s requirements.  
6-20  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
Setting Example)  
To set Address No. 1 with the following requirements:  
(Refer to the Address No. 1 table on the next page.)  
Bit No. 1: Time NON-PRINT (SET status)  
Bit No. 3: Subtotal NON-PRINT (SET status)  
Other bits will be selected to “RESET” status.  
Key Operation: Mode Lock: BLIND, enter 18, depress [X].  
1 [ST] Address No.  
31-10-2005 MON #0  
13 [#] Bit Nos. for SET  
[AT/TL] To complete this setting.  
SYSTEM OP  
#01---------------------------13  
0003  
6-21  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
CONTENTS  
NON-PRINT OPTION I  
0
1
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
RESET PRINT  
REMARKS  
Time (on Sale Receipt,  
Report, Program  
Receipt)  
*
*
*
*
*
*
*
*
1
2
3
4
5
6
7
8
SET  
NON-PRINT  
RESET PRINT  
Sale Item Count on  
each Sale Receipt  
SET  
NON-PRINT  
Subtotal Amount print  
by [ST] key on Receipt  
and Journal  
RESET PRINT  
NOTE 1 below  
SET  
NON-PRINT  
RESET  
-- vacant --  
SET  
Customer Count for  
each Department on  
Department Reports  
RESET PRINT  
SET  
NON-PRINT  
Both Bit 5 & 6 RESET:  
Prints sales % of each  
Department and Group  
Sale % of each  
RESET PRINT  
Department and Group,  
on Department and  
Group Reports (NOTE 2)  
SET  
NON-PRINT  
“Department Gross  
Profit Read Reports”  
can be issued  
Gross Profit of each  
Department, on  
Department Reports  
RESET PRINT  
SET  
NON-PRINT  
regardless of this status  
Sales Person on Sale  
Receipt and Remote  
Slip  
RESET PRINT  
NOTE 3 below  
SET  
NON-PRINT  
NOTE 1: This bit status selection is also applied to the following cases in which the subtotal amount is automatically printed.  
Sale Finalization, % Operation, Amount Discount, and Special Rounding Spec.  
NOTE 2: The sale % of a department = (That Department) / (Sum of Positive Department)  
(When the “Sum of Positive Department” is zero or negative, the sale % of 0% will be printed.)  
The sale % of a negative Status Department is not printed.  
NOTE 3: If SET, no printing is performed on the receipt printer and the Remote Slip Printer during the salesperson entry, however, it is  
performed on the journal regardless of the setting.  
6-22  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
CONTENTS  
0
2
NON-PRINT OPTION II  
SELECTIVE STATUS  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
REMARKS  
RESET  
*
*
*
*
*
*
*
*
-- vacant --  
1
2
3
4
5
6
7
8
SET  
RESET  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
INPS 1 for the Charge  
Posting on Remote Slip  
Printer  
NOE 1 below  
(INPS = Item Not Print  
on Slip)  
RESET PRINT ALL ITEMS  
SET  
INPS 1  
INPS 2 for the Charge  
Posting on Remote Slip  
Printer  
RESET PRINT ALL ITEMS  
NOTE 2 below  
SET  
RESET  
SET  
INPS 2  
This bit must always be  
RESET.  
-- vacant --  
NOTE 1: If SET, print items except the following will not be printed on the Remote Slip Printer in the charge posting operation.  
PB+, PB-, Check Track No., CRT, PB R/A, PB PO and TRF  
NOTE 2: If SET, print items except NEW BAL will not be printed on the Remote Slip Printer in the charge posting operation. Trailer Line  
and NEW BAL will be printed on one line.  
6-23  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
CONTENTS  
6
3
OPTIONAL FUNCTION I  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
RESET Follow Bit 2 status  
*
*
*
*
*
Fraction Rounding  
ROUND UP  
If both RESET, it will be  
ROUND OFF.  
(If both SET, it will be  
ROUND DOWN.)  
1
2
3
4
5
6
7
8
SET  
RESET ROUND OFF  
SET  
ROUND DOWN  
RESET NOT COMPULSORY  
SET  
COMPULSORY  
RESET PROHIBITED  
SET  
ALLOWED  
RESET OPEN  
ROUND UP  
Fraction Rounding  
ROUND DOWN  
NOTE 1 below  
[ST] key before  
finalizing a sale  
Credit Balance in REG  
mode  
NOTE 2 below  
Drawer Opening on  
taking Financial Reports  
SET  
NOT OPEN  
RESET UNIT PRICE x QUANTITY  
Quantity Extension  
(Multiplication) order  
NOTE 3 below  
NOTE 4 below  
NOTE 5 below  
SET  
RESET NOT REQUIRED  
SET  
REQUIRED  
RESET NOT REQUIRED  
SET  
REQUIRED  
QUANTITY x UNIT PRICE  
*
Manager Intervention  
for entering Negative  
Departments/PLUs in  
REG mode  
Manager Intervention  
for finalizing Negative-  
balance Sales in REG  
mode  
*
*
NOTE 1: The selective status of the fraction rounding here applies to quantity extension, %+, and %- calculations. The fraction resulted  
from any tax % calculations (VAT or Add-on Type) will be ROUNDED OFF (no alternative rounding method is provided).  
NOTE 2: The "Credit Balance" means that amount entries through [-] (Amount Discount), [VOID], [STR CPN], [VND CPN], will result in  
over-subtraction of the subtotal amount at the time of the entry through any of those keys. If the SET status (ALLOWED) is  
selected, over-subtraction using these keys will be allowed in the REG mode. The [RTN MDSE] key and negative  
departments/PLUs are not subject to this "Credit Balance" status selection. The Credit Balance is always allowed in the MGR or  
- mode.  
NOTE 3: If RESET, Triple Multiplication operation is not possible. (Doing so may cause an error.)  
NOTE 4: This optional function is effective in the negative department/PLU entry operation. This operation is possible in the MGR or  
- mode regardless of the setting.  
NOTE 5: This optional function is effective for finalizing a negative balance sale by the media keys (excepting the [AT/TL] key).  
This operation is possible in the MGR or - mode regardless of the setting.  
6-24  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
CONTENTS  
23  
4
OPTIONAL FUNCTION II  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
Zero-skip in All  
Department and  
Department Group  
Reports  
Departments/Groups  
with no sale will be  
skipped in the report.  
RESET PRINT all Departments data  
*
1
2
3
4
5
6
7
8
SET  
RESET PRINT all PLUs data  
SET  
ZERO-SKIP  
RESET PRINT all items data  
SET  
ZERO-SKIP  
RESET ACTIVE  
ZERO-SKIP  
Zero-skip in PLU  
Reports  
*
*
Zero-skip on Financial  
and Cashier Reports  
*
*
*
*
*
Cashier feature  
NOTE 1 below  
SET  
NON-ACTIVE  
RESET NOT DISPLAYED  
Cashier No. Display on  
Operator Display  
SET  
DISPLAYED (NOTE 2)  
When both SET or both  
RESET, Department  
No. will be displayed.  
RESET NOT DISPLAYED  
PLU Price Level Display  
on Operator Display  
SET  
RESET  
SET  
DISPLAYED (NOTE 3)  
-- vacant --  
-- vacant --  
RESET  
SET  
NOTE 1: If SET, the cashier feature is not active as the registering operation is possible without cashier sign-ON.  
Cashier read and reset operations are not possible. Doing so may cause an error.  
Cashier signing operation (inputting 4-digit numeric values then [LOG]) in REG mode may cause an error.  
Cashier name is not printed on the validation slip.  
The cashier name portion on the receipt and the journal will be blank. Prior to changing this bit status from RESET to SET,  
the cashier daily/GT reset should be performed to clear the cashier memory. If the bit status is changed without performing  
the reset operation, the cashier memory data will not be guaranteed.  
NOTE 2: If SET, the Cashier No. of the signed-ON cashier is always displayed on the Department Code position (2 digits). Even when a  
department entry is performed, the Cashier No. is displayed instead of the department code.  
NOTE 3: If SET, the PLU Price Level is always displayed on the second leftmost digit of the 7-segment Numeric display.  
-- Address No. 5 is vacant. --  
6-25  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
CONTENTS  
0
6
REMOTE SLIP PRINTER CONTROL  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
Remote Slip Print  
SELECTIVE STATUS  
REMARKS  
RESET NOT COMPULSORY  
*
*
*
*
*
*
*
*
Compulsory for any PB  
entry  
NOTE below  
1
2
3
4
5
6
7
SET  
RESET  
SET  
COMPULSORY  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
8
NOTE:  
If SET, printing operation on the Remote Slip Printer is compulsory. In this case, a slip paper should be set prior to performing  
any Previous Balance entry.  
6-26  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
CONTENTS  
0
7
OPTIONAL FUNCTION III  
SELECTIVE STATUS  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
REMARKS  
RESET  
*
*
*
*
*
*
*
*
-- vacant --  
1
2
3
4
5
6
7
SET  
RESET  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET PRINT and ISSUE  
Cashier Sign ON/OFF  
Receipts  
NOTE below  
SET  
NOT ISSUE  
RESET NOT OPEN  
Drawer Open by  
Cashier Sign ON/OFF  
SET  
RESET  
SET  
OPEN  
-- vacant --  
8
NOTE:  
If SET, the cashier sign-ON/OFF receipt will not be issued. However, the printing operation is performed on the journal  
regardless of the setting. When the automatic cashier sign-OFF function is active (i.e. the SET status is selected in Address No.  
32, Bit No. 3), the cashier sign-OFF print is performed neither on the receipt nor on the journal regardless of the status of Address  
No. 7, Bit No. 6.  
-- Address Nos. 8 to 10 are vacant. --  
6-27  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
11  
CONTENTS  
568  
NON-PRINT OPTION III  
SELECTIVE STATUS  
BIT  
STANDARD  
STATUS  
ITEM  
REMARKS  
NO.  
RESET  
SET  
*
*
*
*
-- vacant --  
1
2
3
4
5
6
7
8
RESET  
SET  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
RESET COUNT  
[C] (Clear) Key Counter  
on Reports  
SET  
NON-COUNT  
*
*
Financial and Cashier  
Daily Read Counter on  
Reports  
RESET PRINT  
NOTE 1 below  
SET  
NON-PRINT  
RESET  
*
-- vacant --  
SET  
RESET PRINT (NOTE 2 below)  
[C] (Clear) Key on  
Journal  
SET  
NON-PRINT  
*
NOTE 1: If RESET, when performing a financial read/reset or cashier read/reset operation, their respective read counter (X counter) is  
printed on the report. (For details, please refer to the Table below.) The read counter (X counter) increases by one regardless of  
this bit status.  
Table: X counter and Z counter print  
Daily  
GT  
X Counter  
Printed  
Printed  
---  
Z Counter  
X Counter  
---  
---  
Printed  
Printed  
Z Counter  
Daily Read  
Daily Reset  
GT Read  
---  
Printed  
---  
---  
---  
---  
GT Reset  
---  
---  
Printed  
NOTE 2: The descriptor “CLEAR” (programmable) is printed on Journal every time the [C] key is operated in the REG mode to clear a  
numeric value or declaration key error. However, it will not be printed when the [C] key is depressed to clear an error condition.  
Additionally, this printing will not be recorded in the MGR or - mode. It will be performed neither on the Receipt nor Remote Slip  
Printer in any mode.  
- - Address Nos. 12 to 16 are vacant. - -  
6-28  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
17  
CONTENTS  
4
OPTIONAL FUNCTION IV  
SELECTIVE STATUS  
BIT  
STANDARD  
STATUS  
ITEM  
REMARKS  
NO.  
RESET  
SET  
*
*
*
-- vacant --  
1
2
3
4
5
6
7
8
RESET  
SET  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET HOLD  
Price Shift Function  
-- vacant --  
NOTE below  
SET  
RESET  
SET  
ONE-TIME  
*
*
*
*
*
RESET  
SET  
-- vacant --  
RESET  
SET  
-- vacant --  
RESET  
SET  
-- vacant --  
SET:  
When the [2nd PRICE] or [3rd PRICE] key is pressed, second or third price level is active for the next PLU entry only.  
Then first price level is automatically regained.  
NOTE:  
RESET:  
SET:  
When the [2nd PRICE] or [3rd PRICE] key is depressed, the second or third price level is held during a sale  
transaction. After finalizing a sale, the first price level is automatically regained.  
When the [2nd PRICE] or [3rd PRICE] key is depressed, the second or third price level is active for the next PLU  
entry only. Then the first price level is automatically regained.  
- - Address No. 18 is vacant. - -  
6-29  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
19  
CONTENTS  
0
CONSIGNMENT OPTION  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
RESET SINGLE-CONSIGNMENT  
*
*
*
*
Single-Consignment or  
Multi-Consignment  
NOTE 1 below  
1
2
3
SET  
MULTI-CONSIGNMENT  
RESET PRINT  
Date Print  
SET  
NON-PRINT  
RESET PRINT  
Consecutive No. (of  
Receipt) Print  
SET  
NON-PRINT  
RESET  
-- vacant --  
4
SET  
RESET PRINT  
*
*
*
*
Cashier Code Print  
5
6
7
8
SET  
NON-PRINT  
Logo, Store Message,  
Commercial Message,  
Footer Message Print  
RESET PRINT  
SET  
NON-PRINT  
Receipt feed after the  
trailer line print  
(5-line feed)  
RESET NO FEED  
If both RESET, no receipt  
feed is performed. (A long  
receipt is issued.)  
If both SET, a 10-line feed is  
performed.  
SET  
FIVE-LINE FEED  
Receipt feed after the  
trailer line print  
RESET NO FEED  
(NOTE 2 below)  
(10-line feed)  
SET  
TEN-LINE FEED  
NOTE 1: “SINGLE-CONSIGNMENT” means that consignment of the same item can be printed only once. (A second attempt to print the  
same item will result in an error.)  
“MULTI-CONSIGNMENT” means that consignment of the same item may be printed any number of times.  
NOTE 2: The number of line feeds after printing a trailer line (cashier name, consecutive No., current time) is selected.  
If only Bit No. 7 is SET, a five-line feed will be performed.  
If both Bit No. 7 and No. 8 are SET, a ten-line feed will be performed.  
If both are RESET, no line feed is performed.  
6-30  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
20  
CONTENTS  
TAX CONTROL I  
0
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
RESET CLOSE  
SET  
OPEN  
RESET CLOSE  
SET  
OPEN  
RESET CLOSE  
SET  
OPEN  
RESET CLOSE  
SET  
OPEN  
RESET CLOSE  
SET  
OPEN  
RESET CLOSE  
SET  
OPEN  
RESET CLOSE  
SET  
OPEN  
RESET CLOSE  
SET  
OPEN  
REMARKS  
*
*
*
*
*
*
*
*
Add-on Tax 1  
Open/Close  
1
2
3
4
5
6
7
Add-on Tax 2  
Open/Close  
Add-on Tax 3  
Open/Close  
Add-on Tax 4  
Open/Close  
Add-on Tax 5  
Open/Close  
Add-on Tax 6  
Open/Close  
Add-on Tax 7  
Open/Close  
Add-on Tax 8  
Open/Close  
8
NOTE:  
This optional function is effective when Address No. 21, Bit No. 5 has been SET (Add-on Tax feature).  
When SET status is selected on the ECR adopting the Add-on Tax feature, Tax 1 through Tax 8 are open.  
When Taxable status (SET status) is set to the [-], [%+], [%-], and [VND CPN] keys in the Key Status Programming, Tax 1  
through Tax 8 are processed according to this bit status (Open/Close). VAT feature is not subject to this bit status.  
6-31  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
21  
CONTENTS  
TAX CONTROL II  
0
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
RESET NON-PRINT  
REMARKS  
*
*
*
*
*
*
*
*
Multiple Taxes Separate  
Print on Receipt  
1
2
3
4
5
6
7
8
SET  
SEPARATE PRINT  
When Add-on Tax  
feature is selected at  
Bit No. 5, taxes are  
always printed.  
RESET NON-PRINT  
Tax Total Amount on  
Receipt  
SET  
RESET NON-PRINT  
SET  
PRINT  
RESET (Price x Rate) ÷ (1 + Rate)  
SET  
(Price x Rate)  
RESET VAT  
PRINT  
Taxable Total Print on  
Receipt  
NOTE 1 below  
This bit status selection  
is effective only when  
VAT feature has been  
selected.  
VAT Calculation Method  
(VAT = )  
Tax Type:  
VAT or Add-on Tax  
NOTE 2 below  
SET  
ADD-ON TAX  
This bit status selection  
is effective only when  
VAT feature has been  
selected.  
NET VAT Total  
Separate Print on  
Receipt (NOTE 3)  
RESET NON-PRINT  
SET  
RESET  
SET  
PRINT  
-- vacant --  
This bit status selection  
is effective only when  
VAT feature has been  
selected.  
RESET NON-PRINT  
SET  
PRINT  
NET Total Print on  
Receipt (NOTE 4)  
NOTE 1: Whether the taxable total is printed on the receipt is selected.  
SET: It is printed individually.  
RESET: It is not printed.  
NOTE 2: When the Add-on Tax feature is selected:  
1) The [TX1/M] to [TX8/M] keys can reverse the respective Tax status of Departments and PLUs. Reversing the Tax status of  
[% +], [% -], and [-] is also possible. (Neither the [TX1/M] to [TX7/M], nor [TX8/M] keys can be used when the VAT feature is  
selected.)  
2) When a taxable item (subject to any of Tax 1 to Tax 8) is entered in a sale, the symbol “T” is printed to the right of the item  
amount.  
NOTE 3: Whether the NET VAT total of each VAT is printed on the receipt is selected.  
SET:  
It is printed.  
RESET: It is not printed.  
NOTE 4: Whether the NET total (amount total not including VAT total) is printed on the receipt is selected.  
SET:  
It is printed.  
RESET: It is not printed.  
6-32  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
22  
CONTENTS  
TAX CONTROL III  
0
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
RESET NON-PRINT  
REMARKS  
*
*
*
*
*
*
*
*
VAT Symbol Print  
NOTE 1 below  
1
2
3
4
5
6
7
8
SET  
RESET  
SET  
PRINT  
NET TL VAT TL  
VAT TL NET TL  
Print order of VAT TL  
and NET TL  
NOTE 2 below  
RESET NONE  
Single line spacing  
under each VAT  
NOTE 3 below  
SET  
RESET  
SET  
SINGLE LINE SPACING  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
NOTE 1: If SET, the VAT symbols (A to H) are printed. They will be programmable in the Print Line Item Name Programming.  
NOTE 2: This bit status selection is effective when the following options have been SET.  
Address No. 21, Bit No. 2:  
Address No. 21, Bit No. 8:  
Tax total amount print  
NET total print  
NOTE 3: This bit status selection is effective when one of the following options has been SET.  
Address No. 21, Bit No. 1:  
Address No. 21, Bit No. 3:  
Address No. 21, Bit No. 6:  
Tax separate print  
Taxable total print  
NET VAT total separate print  
- - Address Nos. 23 to 26 are vacant. - -  
6-33  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
27  
CONTENTS  
DRAWER OPTION  
1
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
RESET NOT COMPULSORY  
SET  
COMPULSORY  
RESET NON-ACTIVE  
SET  
ACTIVE  
RESET SINGLE DRAWER  
SET  
MULTI DRAWER  
RESET BY CASHIER  
SET  
BY CURRENCY  
RESET IN DOMESTIC CURRENCY  
SET  
IN FOREIGN CURRENCY  
RESET 1 DRAWER  
REMARKS  
Drawer Close  
Compulsory  
NOTE 1 below  
1
2
3
4
5
6
7
8
*
*
*
*
*
*
*
*
Drawer Warning Alarm  
NOTE 2 below  
Single-drawer or Multi-  
drawer  
NOTE 3 below  
Multi-drawer Control  
Selection of Change at  
Tendering in Foreign  
Currencies  
NOTE 4 below  
Number of Drawers  
(if Multi-drawer spec.)  
SET  
RESET  
SET  
2 DRAWERS  
-- vacant --  
-- vacant --  
RESET  
SET  
NOTE 1:  
NOTE 2:  
If SET, the Drawer-close Compulsory option is active. In this case, when the drawer remains open, any operations except [RF], [JF], [C], numeric  
input for Sign-ON are prohibited. This rule is applied in REG, MGR, - , and LOCK modes; in the other modes, the drawer may remain open.  
This bit status selection is effective only when Bit No. 1 is SET. If SET (ACTIVE), the setting in the DRAWER WARNING TIME operation will be  
effective. In this operation, a time value in seconds can be set for the time length with the drawer open until the warning alarm generated (the initial  
value is 15 seconds).  
NOTE 3:  
NOTE 4:  
If SET, the Multi-drawer specification is selected.  
In the case of Cashier Code Entry Method (using [LOG] or [LOG/RECEIPT] key), a drawer is to be designated in sale entries, and the number of  
drawers will be further selected at Bit No. 6.  
In the case of Cashier Key Method, the drawer to be used will be fixed as in the following:  
Drawer 1 for Cashier 1, Drawer 2 for Cashier 2 & all others.  
This bit status selection is available regardless of the status selection for the bit No. 3 and the bit No. 4 in this address.  
If RESET, change is returned to a customer by the domestic currency in the foreign currency tendering operation.  
If SET, change is returned to a customer by the foreign currency, the symbol “  
display.  
” is displayed in the leftmost 2 digits on the 7-segment Numeric  
• When change is returned to a customer by the foreign currency, the symbol “  
” will always be displayed even if the option of the cashier No.  
display or the PLU price level display (Bits No. 5 and No. 6 of Address No. 4) has been selected.  
• When change is returned to a customer by the foreign currency, the Drawer 2 will open if both the bit No. 3 and the bit No. 4 in this address have  
been “SET”.  
6-34  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
28  
CONTENTS  
0
OPTIONAL FUNCTION VI  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
RESET ALLOWED  
*
*
*
*
*
*
*
*
No-sale Entry After  
Non-add # Entry  
1
2
3
4
5
6
7
SET  
RESET ANY NUMBER OF TIMES  
SET  
ONLY ONCE ALLOWED  
RESET ALLOWED  
SET  
PROHIBITED  
RESET PRINT  
PROHIBITED  
Number of Times for  
Non-add # Entries  
Within a Receipt  
[RF] Operation During a  
Sale  
[JF] is allowed anytime.  
Even when NON-PRINT,  
the Consecutive No. is  
counted in memory.  
Consecutive No. on  
Receipt and Journal  
SET  
NON-PRINT  
RESET NON-RESETTABLE  
Consecutive No.  
Resetting  
NOTE below  
SET  
RESET ON Financial Daily Z  
RESET ALLOWED  
Negative Mode ( - )  
Operation  
SET  
PROHIBITED  
RESET OPEN  
Drawer Open when  
operating the [TRF] key  
SET  
RESET  
SET  
NOT OPEN  
-- vacant --  
8
NOTE:  
If SET status is selected, the Consecutive No. will start from “0001” on the first receipt issued after every Financial Daily Reset  
Report.  
6-35  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
29  
CONTENTS  
6
OPTIONAL FUNCTION VII  
SELECTIVE STATUS  
BIT  
STANDARD  
STATUS  
ITEM  
REMARKS  
NO.  
RESET  
SET  
*
*
*
*
*
-- vacant --  
1
2
3
4
5
6
7
RESET  
SET  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET PRINT  
Footer Message Print  
-- vacant --  
NOTE below  
SET  
RESET  
SET  
NON-PRINT  
*
*
*
RESET  
SET  
-- vacant --  
8
NOTE:  
Footer message print is selected.  
SET:  
NON-PRINT  
RESET:  
It is printed under the trailer line (cashier name, consecutive No., current time).  
6-36  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
30  
CONTENTS  
0
OPTIONAL FUNCTION VIII  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
IPD or INPD on Journal  
in REG and MGR  
modes  
RESET IPD  
*
*
*
*
*
*
*
*
NOTE 1 below  
1
2
3
4
5
6
7
8
SET  
RESET  
SET  
INPD  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
-- vacant --  
RESET  
SET  
-- vacant --  
RESET PROHIBITED  
Cashier Interrupt  
-- vacant --  
NOTE 2 below  
SET  
RESET  
SET  
ALLOWED  
RESET  
SET  
-- vacant --  
NOTE 1: RESET:  
IPD (Items Printed Detail) ······················Details of the sale entry are printed on journal, just as on receipts.  
INPD (Items Not Printed Detail) ·············Details of the Department/PLU entry in REG or MGR mode (excepting  
Returned Merchandise, Item Correct, Negative Dept./PLU, Void, All Void) are  
omitted on the journal only.  
SET:  
NOTE 2: RESET:  
Cashier Interrupt function is prohibited.  
Cashier Interrupt function is allowed.  
SET:  
6-37  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
31  
CONTENTS  
0
OPTIONAL FUNCTION IX  
SELECTIVE STATUS  
BIT  
STANDARD  
STATUS  
ITEM  
REMARKS  
NO.  
RESET  
*
*
*
*
*
*
*
*
-- vacant --  
1
2
3
4
5
6
7
8
SET  
RESET  
-- vacant --  
SET  
Date, day of week, and  
Register No. print on  
Journal  
RESET NON-PRINT  
NOTE 1 below  
SET  
RESET  
SET  
PRINT  
-- vacant --  
Selection of the Store  
Name Message or Store  
Name Logo on Receipt  
RESET STORE NAME LOGO  
NOTE 2 below  
SET  
RESET  
SET  
STORE NAME MESSAGE  
This bit must always be  
RESET.  
-- vacant --  
Group Print in All  
Department Read  
Report  
RESET NON-PRINT  
NOTE 3 below  
SET  
RESET  
SET  
PRINT  
-- vacant --  
NOTE 1: If SET, date, day of week, and register No. are printed on the journal.  
In X and Z modes, they are printed on the journal regardless of this bit status selection.  
NOTE 2: Either Store Name Message or Store Name Logo is selected. If SET, the Store Name Message specification is active. When  
none of store name message has been programmed, its corresponding portion on the receipt will be blank.  
NOTE 3: Whether the group is printed on the all department read report is selected. If SET, it will be printed. Additionally, the group is  
printed on the reset report regardless of this bit status selection.  
6-38  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
32  
CONTENTS  
0
OPTIONAL FUNCTION X  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
RESET ANY NUMBER OF TIMES  
*
*
*
*
*
*
*
*
[%+] and [%-] after a  
Subtotal within a Sale  
1
2
3
4
5
6
7
8
SET  
RESET  
SET  
ONLY ONCE ALLOWED  
-- vacant --  
RESET NON-ACTIVE  
SET  
ACTIVE  
RESET USED AS [%+] KEY  
SET  
USED AS [%-] KEY  
RESET USED AS [%-] KEY  
SET  
USED AS [%+] KEY  
RESET Sale Total Including PB  
SET  
Sale Total Excluding PB  
RESET NOT COMPULSORY  
SET  
COMPULSORY  
RESET ALLOWED  
SET  
PROHIBITED  
Automatic Cashier Sign  
OFF on finalizing a sale  
NOTE 1 below  
[% I] key Use (= SFKC  
70)  
NOTE 2 below  
[% II] key Use (= SFKC  
71)  
Amount Print on [CRT]  
Depression to Finalize a  
Sale including Previous  
Balance  
Displays Sale Total  
amount including PB in  
either status  
Salesperson Sign-ON  
Before Sale Item Entries  
NOTE 3 below  
Salesperson Sign-ON  
Anytime During a Sale  
NOTE 1: If SET (ACTIVE), the signed-ON cashier will automatically be signed OFF on finalizing each sale. At the automatic cashier sign  
OFF, the description “SIGN OFF” is printed neither on the receipt nor on the journal.  
NOTE 2: Bit No.4 and No.5 are provided in case your user wants two [%-] keys or two [%+] keys rather one for each.  
One [%+] and one [%-] (Standard Bit Status):  
Two [%-] keys:  
Bit No. 4…..RESET (%I = %+), Bit No. 5…..RESET (%II = %-)  
Bit No. 4…..SET (%I = %-), Bit No. 5…..RESET(%II = %-)  
In this case, do not forget to change the Financial Total Name of the %I key.  
Two [%+] keys: Bit No. 4…..RESET (%I = %+), Bit No. 5…..SET (%II = %+)  
In this case, do not forget to change the Financial Total Name of the %II key.  
NOTE 3: NOT COMPULSORY:  
A Salesperson Sign-ON may or may not be operated for sale entries.  
COMPULSORY:  
A Salesperson must sign ON first of all the sale items of Department, PLU, Amount Discount, Vendor  
Coupon, or PB+, PB-, entries.  
6-39  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
33  
CONTENTS  
2
OPTIONAL FUNCTION XI  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
RESET Follow Bit 2 status  
*
Date Set and Print  
Order  
If both RESET, it will be  
YEAR-MONTH-DAY  
order.  
(If both SET, it will  
result in MONTH-DAY-  
YEAR.)  
1
2
3
4
5
6
7
SET  
RESET Follow Bit 1 status  
SET  
DAY-MONTH-YEAR  
RESET NON-ACTIVE  
SET  
ACTIVE  
RESET 1 DIGIT  
SET  
2 DIGITS  
MONTH-DAY-YEAR  
Date Set and Print  
Order  
*
The digit selection (Bit  
No. 4) and SPECIAL  
ROUNDING PROCESS  
are further necessary.  
*
*
*
*
*
*
Special Rounding on  
Sale Total  
Number of Digits  
Subject to Special  
Rounding  
Denmark Special  
Rounding/Australia  
Special Rounding  
RESET NORMAL SP. ROUND  
NOTE below  
DENMARK SP. ROUND/  
SET  
AUSTRALIA SP. ROUND  
RESET  
SET  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
8
NOTE:  
To realize the Denmark Special Rounding feature or the Australia Special Rounding feature, set Bit No.3 through No.5 in this  
address as follows.  
for Denmark Special Rounding feature  
System Option  
Special rounding on sale total  
Number of digits subject to special rounding  
Denmark special rounding  
SET  
O
O
RESET  
Remarks  
(Bit No.3)  
(Bit No.4)  
(Bit No.5)  
2-digit type  
O
Set the rounding table of the Denmark Special Rounding in accordance with SPECIAL ROUNDING PROCESS SETTING, 2-  
digit type.  
for Australia Special Rounding feature  
System Option  
SET  
RESET  
Remarks  
Special rounding on sale total  
Number of digits subject to special rounding  
Australia special rounding  
(Bit No.3)  
(Bit No.4)  
(Bit No.5)  
O
O
1-digit type  
O
Set the rounding table of the Australia Special Rounding in accordance with SPECIAL ROUNDING PROCESS SETTING, 1-  
digit type.  
6-40  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
34  
CONTENTS  
12  
OPTIONAL FUNCTION XII  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
RESET  
REMARKS  
-- ex) 1.5%  
.
,
.
,
.
,
(POINT)  
Decimal Point in Item  
Count and % Rate  
1
2
3
4
5
6
7
8
SET  
RESET  
SET  
-- ex) 1,5%  
-- ex) €2.50  
-- ex) €2,50  
-- ex) ¥1.000  
-- ex) ¥1,000  
(COMMA)  
(POINT)  
*
*
Amount Division Symbol  
between Main and  
Subsidiary digits for  
0.00 type  
(COMMA)  
(POINT)  
Amount Division Symbol  
between 3rd and 4th  
digits for . - - 0  
RESET  
SET  
*
*
*
*
*
*
(COMMA)  
RESET  
SET  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
- - Address Nos. 35 is vacant. - -  
6-41  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
36  
CONTENTS  
0
FOREIGN CURRENCY OPTION  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
[CUR 1] (Foreign  
Currency 1) Zero-  
suppress Display  
RESET 0.00 ($, €, £, etc.)  
*
*
*
*
*
*
*
*
1
2
3
4
5
6
7
8
SET  
. - - 0 (such as Japan yen)  
[CUR 2] (Foreign  
Currency 2) Zero-  
suppress Display  
RESET 0.00 ($, €, £, etc.)  
SET  
. - - 0 (such as Japan yen)  
[CUR 3] (Foreign  
Currency 3) Zero-  
suppress Display  
These bits selections  
are also applied to the  
print.  
RESET 0.00 ($, €, £, etc.)  
SET  
. - - 0 (such as Japan yen)  
[CUR 4] (Foreign  
Currency 4) Zero-  
suppress Display  
RESET 0.00 ($, €, £, etc.)  
SET  
. - - 0 (such as Japan yen)  
[CUR 5] (Foreign  
Currency 5) Zero-  
suppress Display  
RESET 0.00 ($, €, £, etc.)  
SET  
. - - 0 (such as Japan yen)  
Foreign Currency  
Tender Amount Print in  
payment of a sale  
RESET NON-PRINT  
SET  
RESET NON-PRINT  
SET  
PRINT  
RESET PROHIBITED  
SET  
ALLOWED  
PRINT  
Foreign Currency  
Exchange Rate Print in  
payment or No-sale  
Exchange  
Exchange from a  
No-sale Exchange from  
Domestic to Foreign  
Currencies  
Foreign Currency to the  
Domestic currency is  
always allowed.  
6-42  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
37  
CONTENTS  
0
OPTIONAL FUNCTION XIII  
SELECTIVE STATUS  
BIT  
STANDARD  
STATUS  
ITEM  
REMARKS  
NO.  
RESET  
*
*
*
*
*
*
*
*
-- vacant --  
1
2
3
4
5
6
7
8
SET  
Department Memory  
Process for %- on  
Department Item  
RESET GROSS PROCESS  
SET  
RESET GROSS PROCESS  
SET  
NET PROCESS  
RESET ITEMIZED RECEIPT  
NET PROCESS  
NOTE 1 below  
PLU Memory Process  
for %- on PLU Item  
Post-issue Receipt Print  
Form  
NOTE 2 below  
SET  
RESET  
SET  
TOTAL-ONLY RECEIPT  
-- vacant --  
-- vacant --  
RESET  
SET  
% Calculation on  
additional item entries  
after Subtotal and %  
entries  
RESET Calculates on the entire sale  
NOTE 3 below  
Calculates on the additional  
items  
SET  
RESET  
SET  
-- vacant --  
NOTE 1: If RESET status (GROSS PROCESS) is selected, %- calculation is performed on the subtotal amount but not processed into  
each item memory.  
If SET status (NET PROCESS) is selected, %- calculation is performed on each entry item and processed into each item memory.  
NOTE 2: If RESET status is selected, a sale of maximum of 30 lines will be issued as an itemized receipt. Exceeding 30 lines, a total-only  
receipt will be issued.  
If SET status is selected, a total-only receipt will always be issued for the post-issue receipt operation.  
After the [TRF] key operation, the amounts of credit sale total and new balance are printed. The amount of credit sale total is  
printed according to the Address No. 32, Bit No. 6 setting (Amount print on [CRT] depression to finalize a sale including  
previous balance).  
After the [R/A] key operation, the amounts of received-on-account and the new balance are printed.  
NOTE 3: If SET status is selected, % calculation is performed on the additional items entered after the first Subtotal and % entries and  
before the second Subtotal and % entries (i.e., on the group subtotal)  
ex) Department Entries [ST] [%+]  
Department Entries [ST] [%-] ..........  
(A)  
(B)  
Calculates % on the amount of Group (B) not  
including Group (A).  
6-43  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
38  
CONTENTS  
0
OPTIONAL FUNCTION XIV  
SELECTIVE STATUS  
BIT  
STANDARD  
STATUS  
ITEM  
REMARKS  
NO.  
RESET  
*
*
*
*
*
*
*
*
-- vacant --  
1
2
3
4
5
6
7
SET  
RESET  
-- vacant --  
SET  
Cashier Identifying  
Method:  
Push SFKC Keys  
RESET CODE ENTRY METHOD  
NOTE below  
SET  
RESET  
SET  
PUSH SFKC KEYS  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
8
NOTE:  
If SET, PUSH SFKC KEYS specification is effective.  
CODE ENTRY METHOD:  
A cashier signs ON by entering a 4-digit code and the [LOG/RECEIPT] key.  
PUSH SFKC KEYS:  
Cashier keys can be programmed on the keyboard by the SFKC programming. A cashier signs ON  
by depressing a cashier key assigned on the keyboard. This cashier is valid until another cashier  
key is depressed.  
6-44  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
39  
CONTENTS  
0
OPTIONAL FUNCTION XV  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
RESET PROHIBITED  
*
*
*
*
*
*
*
*
Money Declaration  
Operation  
NOTE 1 below  
1
2
3
4
5
6
7
8
SET  
COMPULSORY  
RESET EACH CASHIER  
Money Declaration is  
performed by:  
NOTE 2 below  
SET  
RESET  
SET  
PERMITTED CASHIER  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
NOTE 1: The Money Declaration Operation Compulsory (SET) status may be selected only when the ECR adopts the PUSH SFKC Keys  
Method (not CODE ENTRY method).  
Whether Money Declaration is to be operated by individual cashiers or totally by the permitted cashier is determined by the  
Bit No. 2 status selection.  
With this option selected, the following reports cannot be taken: Media Sales and In-drawer Total Read, All Media  
Sales Total and Cash-in-Drawer Read, Daily All Cashier Read/Reset, Daily Individual Cashier Read/Reset. (However, when  
Bit 2 is SET, the Daily All Cashier Read/Reset Report and the Daily Individual Cashier Read/Reset Report can be printed.)  
When Bit No. 2 is RESET, the Daily Financial Read/Reset Report can be issued only after a Money Declaration operation for  
all the cashiers. When Bit No. 2 is set, these reports can be printed by the permitted cashier after performing a Money  
Declaration operation.  
NOTE 2: If SET status (PERMITTED CASHIER) is selected, the in-drawer amount entries are totally performed by the permitted cashier.  
In this case, the media difference memory will not be processed in the Cashier Reports but the Financial Reports.  
- - Address Nos. 40 and 41 are vacant. - -  
6-45  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
42  
CONTENTS  
0
OPTIONAL FUNCTION XVI  
SELECTIVE STATUS  
BIT  
STANDARD  
STATUS  
ITEM  
REMARKS  
NO.  
RESET  
SET  
*
*
*
*
*
*
*
*
-- vacant --  
1
2
3
4
5
6
7
RESET  
SET  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
Consecutive No. Print  
immediately after the  
previous daily financial  
reset  
RESET NON-PRINT  
NOTE below  
8
SET  
PRINT  
NOTE:  
If SET status is selected, the consecutive No. immediately after the previous daily financial reset is printed on the daily financial  
reset report. (Columbia specification)  
After a RAM Clear or Data Clear, the consecutive No. will be cleared.  
- - Address Nos. 43 to 46 are vacant. - -  
6-46  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
47  
CONTENTS  
0
PC OPTION  
BIT  
STANDARD  
STATUS  
ITEM  
NO.  
SELECTIVE STATUS  
REMARKS  
RESET  
SET  
*
*
*
*
*
*
*
*
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
1
2
3
4
5
6
7
8
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET PRINT ALL PLU DATA  
Zero-skip of PLU Data  
when transmitting to PC  
SET  
RESET  
SET  
ZERO-SKIP  
-- vacant --  
-- vacant --  
RESET  
SET  
- - Address No. 48 is vacant. - -  
6-47  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.5 System Option Programming  
System Option Table  
Standard Bit Set (auto-set by RAM Clear)  
ADDRESS NO.  
49  
CONTENTS  
0
OPTIONAL FUNCTION XVII  
BIT  
NO.  
STANDARD  
STATUS  
ITEM  
SELECTIVE STATUS  
REMARKS  
RESET STANDARD PRINTING  
*
*
*
*
*
*
*
*
Narrow Printing on  
Journal  
NOTE 1 below  
1
2
3
4
5
6
7
8
SET  
RESET  
SET  
NARROW PRINTING  
-- vacant --  
RESET CONNECTED  
Disconnection of the  
Journal Printer  
NOTE 2 below  
SET  
RESET  
SET  
DISCONNECTED  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
RESET  
SET  
RESET  
SET  
RESET  
SET  
RESET  
SET  
NOTE 1: Narrow printing on journal  
SET: Journal print is performed with narrow printings.  
RESET: Journal print is performed with standard printings.  
NOTE 2: If SET status is selected, the Journal Printer is disconnected. Only the receipt print will be performed.  
When this status is changed from SET (the Journal Printer is disconnected) to RESET (the Journal Printer is connected), power  
off then on the ECR.  
6-48  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.6 Commercial Message Programming  
6.6  
Commercial Message Programming  
A maximum of 96 characters of Commercial Message (32 characters x 3 lines) to be printed on the receipt is  
programmed here.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
Main Menu  
1 MESSAGES” for various message programming is selected.  
Depress [1] or [Enter].  
1 COMMERCIAL MESSAGE” is selected.  
The message already programmed is displayed.  
Depress [1] or [Enter].  
*
The ECR enters the 1st line message input mode.  
[Enter]  
A maximum of 32 one-byte or 16 two-byte characters are input.  
The 1st line message is entered and the programmed data is printed.  
The ECR enters the 2nd line message input mode.  
Input a message in the 1st line.  
[Enter]  
[Enter]  
Input a message in the 2nd line.  
[Enter]  
A maximum of 32 one-byte or 16 two-byte characters are input.  
The 2nd line message is entered and the programmed data is printed.  
The ECR enters the 3rd line message input mode  
[Enter]  
A maximum of 32 one-byte or 16 two-byte characters are input.  
The 3rd line message is entered and the programmed data is printed.  
Input a message in the 3rd line.  
[Enter]  
This programming is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
*: To program a message in a desired line, move the cursor there with  
the [] key then depress the [Enter] key.  
NOTES:  
1. For each line, a maximum of 32 one-byte characters or 16 two-byte characters can be entered.  
A combination of both types is also available.  
2. If three blank lines are programmed for a commercial message, their portions on the receipt will be closed.  
If at least one line message is programmed, the other two lines will be blank.  
6-49  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.6 Commercial Message Programming  
3) Example:  
To program the following Commercial Message.  
O p e n  
l o e d  
8
:
0 0 a m  
t
o
7
:
0 0 p m  
Line No. 1  
C
s
:
e v e  
r
y
W e d n e s d a y  
Line No. 2  
Line No. 3  
Operation  
LCD Display  
Remarks  
When the ECR is being outside a sale  
and in SET mode, depress the [1] or  
[Enter] key.  
Depress the [1] or [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
The message already programmed is  
displayed.  
(To program a message in a desired  
line, move the cursor there with the []  
key then depress the [Enter] key.)  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
The [Enter] key depression allows the  
ECR to enter the 1st line message  
input mode. (The [C] key depression  
clears the message already  
programmed.) The 1st line message is  
input.  
Example of key operation)  
[] [] [] [] [] [O] [A/a] [p] [e] [n]  
[] [] [3] [0] [8] [#] [3] [1] [0] [#] [3] [0]  
[0] [#] [3] [0] [0] [#] [a] [m] [] [t] [o] []  
[3] [0] [7] [#] [3] [1] [0] [#] [3] [0] [0] [#] [3]  
[0] [0] [#] [p] [m] [Enter]  
Number of programmed characters  
Number of programmable characters  
When the [Enter] key is depressed, the  
message programmed in the 1st line is  
printed.  
The [Enter] key depression results in  
that the input message is entered and  
displayed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
The [Enter] key depression allows the  
ECR to enter the 2nd line message  
input mode. (The [C] key depression  
clears the message already  
Example of key operation)  
[] [] [] [] [C] [A/a] [l] [o] [s] [e] [d]  
[3] [1] [0] [#] [] [e] [v] [e] [r] [y] [][A/a]  
[W] [A/a] [e] [d] [n] [e] [s] [d] [a] [y] [Enter]  
programmed.) The 2nd line message  
is input.  
(continued on the next page)  
6-50  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.6 Commercial Message Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
When the [Enter] key is depressed, the  
message programmed in the 2nd line is  
printed.  
The [Enter] key depression results in  
that the input message is entered and  
displayed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
The [Enter] key depression allows the  
ECR to enter the 3rd line message  
input mode. (The [C] key depression  
clears the message already  
programmed.) The 3rd line message  
is input.  
Example of key operation)  
[Enter] (No message was input in the 3rd  
line.)  
When the [Enter] key is depressed, the  
message programmed in the 3rd line is  
printed.  
The [Enter] key depression results in  
that the input message is entered and  
displayed.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
NOTE: In the above example, characters except for alphabets are  
entered using the character code entry method.  
31-10-2005 MON #0  
CM NAME  
1
Open 8:00am to 7:00pm  
2
Closed: every Wednesday  
3
0004 13:10TM  
6-51  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.7 Footer Message Programming  
6.7  
Footer Message Programming  
A maximum of 64 characters of Footer Message (32 characters x 2 lines) to be printed on the receipt is  
programmed here.  
Prior to the Footer Message Programming, be sure to select RESET status for Address No. 29, Bit No. 6  
of the system option.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
Main Menu  
1 MESSAGES” for various message programming is selected.  
Depress [1] or [Enter].  
Depress [] then [Enter].  
2 FOOTER MESSAGE” is selected.  
The message already programmed is displayed.  
or  
Depress [2].  
*
The ECR enters the 1st line message input mode.  
[Enter]  
Input a message in the 1st line.  
[Enter]  
A maximum of 32 one-byte or 16 two-byte characters are input.  
The 1st line message is entered and the programmed data is printed.  
The ECR enters the 2nd line message input mode.  
[Enter]  
A maximum of 32 one-byte or 16 two-byte characters are input.  
The 2nd line message is entered and the programmed data is printed.  
Input a message in the 2nd line.  
[Enter]  
This programming is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
*: To program a message in a desired line, move the cursor there with  
the [] key then depress the [Enter] key.  
NOTES:  
1. For each line, a maximum of 32 one-byte characters or 16 two-byte characters can be entered.  
A combination of both types is also available.  
2. Print format is as shown below.  
(Space)  
Cashier Name, Consecutive No., Time  
Footer Logo Message  
6-52  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.7 Footer Message Programming  
3) Example:  
To program the following Footer Message.  
T h a n  
k
y
o u  
Line No. 1  
Line No. 2  
C a  
l
l
a g a  
i
n
Operation  
LCD Display  
Remarks  
When the ECR is being outside a sale  
and in SET mode, depress the [1] or  
[Enter] key.  
The cursor is moved on to “2 FOOTER  
MESSAGE”.  
Depress the [] key.  
Depress the [2] or [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
The message already programmed is  
displayed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
The [Enter] key depression allows the  
ECR to enter the 1st line message  
input mode. (The [C] key depression  
clears the message already  
programmed.) The 1st line message is  
input.  
Example of key operation)  
[] [] [] [] [] [] [T] [A/a] [h] [a] [n]  
[k] [] [A/a] [Y] [A/a] [o] [u] [Enter]  
(To program a message in a desired  
line, move the cursor there with the []  
key then depress the [Enter] key.)  
Number of programmed characters  
Number of programmable characters  
When the [Enter] key is depressed, the  
message programmed in the 1st line is  
printed.  
The [Enter] key depression results in  
that the input message is entered and  
displayed.  
(continued on the next page)  
6-53  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.7 Footer Message Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
The [Enter] key depression allows the  
ECR to enter the 2nd line message  
input mode. (The [C] key depression  
clears the message already  
Example of key operation)  
[] [] [] [] [] [] [] [] [] []  
[] [] [] [] [] [] [C] [A/a] [a] [l] [l]  
[] [a] [g] [a] [i] [n] [Enter]  
programmed.) The 2nd line message  
is input.  
When the [Enter] key is depressed, the  
message programmed in the 2nd line is  
printed.  
The [Enter] key depression results in  
that the input message is entered and  
displayed.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
NOTE: In the above example, characters except for alphabets are  
entered using the character code entry method.  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
FOOTER NAME  
1
Thank You  
2
Call again  
0004 13:13TM  
6-54  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.8 Store Name Message Programming  
6.8  
Store Name Message Programming  
A maximum of 128 characters of Store Name Message (32 characters x 4 lines) to be printed on the receipt is  
programmed here.  
Prior to the Store Name Message Programming, be sure to select SET status for Address No. 31, Bit No. 5  
of the system option.  
CONDITION  
Any time outside a sale  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
Main Menu  
1 MESSAGES” for various message programming is selected.  
Depress [1] or [Enter].  
Depress [] twice then [Enter].  
3 STORE MESSAGE” is selected.  
The message already programmed is displayed.  
or  
Depress [3].  
*
The ECR enters the 1st line message input mode  
[Enter]  
A maximum of 32 one-byte or 16 two-byte characters are input.  
Input a message in the 1st line.  
The 1st line message is entered and the programmed data is printed.  
[Enter]  
The ECR enters the 2nd line message input mode  
[Enter]  
A maximum of 32 one-byte or 16 two-byte characters are input.  
Input a message in the 2nd line.  
The 2nd line message is entered and the programmed data is printed.  
[Enter]  
The ECR enters the 3rd line message input mode  
[Enter]  
A maximum of 32 one-byte or 16 two-byte characters are input.  
Input a message in the 3rd line.  
The 3rd line message is entered and the programmed data is printed.  
[Enter]  
The ECR enters the 4th line message input mode  
[Enter]  
A maximum of 32 one-byte or 16 two-byte characters are input.  
Input a message in the 4th line.  
The 4th line message is entered and the programmed data is printed.  
[Enter]  
This programming is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
*: To program a message in a desired line, move the cursor there with  
the [] key then depress the [Enter] key.  
6-55  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.8 Store Name Message Programming  
NOTES: 1. For each line, a maximum of 32 one-byte characters or 16 two-byte characters can be entered.  
A combination of both types is also available.  
2. When blanks are entered for the whole one line, it results in one line feed.  
3. When the store name message specification has been selected, the 4-line range assigned for the  
store name message is either printed or fed, regardless of any system option selection.  
4. Print format for each specification is as shown below.  
1) Store Name Logo specification  
When Commercial Message is SET  
When Commercial Message is RESET  
Store Name Logo  
Store Name Logo  
Date, Register No.  
Commercial Message  
(Space)  
Description  
(Space)  
Date, Register No.  
(Space)  
Description  
2) Store Name Message specification  
When Commercial Message is SET  
When Commercial Message is RESET  
Store Name Message  
Store Name Message  
Commercial Message  
(Space)  
Date, Register No.  
(Space)  
(Space)  
Description  
Date, Register No.  
(Space)  
Description  
6-56  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.8 Store Name Message Programming  
3) Example:  
To program the following Store Message.  
T E C  
S T O R E  
Line No. 1  
1 3 4 3  
P E A C H  
8 7  
D R I V E  
6 4 3 7  
Line No. 2  
Line No. 3  
Line No. 4  
P H O N E :  
-
Operation  
LCD Display  
Remarks  
When the ECR is being outside a sale  
and in SET mode, depress the [1] or  
[Enter] key.  
The cursor is moved on to “3 STORE  
MESSAGE”.  
Depress the [] key twice.  
Depress the [3] or [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
The message already programmed is  
displayed.  
To program a message in a desired line,  
move the cursor there with the [] key then  
depress the [Enter] key.  
The [Enter] key depression allows the  
ECR to enter the 1st line message  
input mode. (The [C] key depression  
clears the message already  
programmed.) The 1st line message is  
input.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Number of programmed characters  
Number of programmable characters  
When the [Enter] key is depressed, the  
message programmed in the 1st line is  
printed.  
The [Enter] key depression results in  
that the input message is entered and  
displayed.  
Example of key operation)  
[] [] [] [] [] [][] [Dbl] [T] [E]  
[C] [] [S] [T] [O] [R] [E] [Enter]  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
The [Enter] key depression allows the  
ECR to enter the 2nd line message  
input mode. (The [C] key depression  
clears the message already  
programmed.) The 2nd line message  
is input.  
(continued on the next page)  
6-57  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.8 Store Name Message Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
When the [Enter] key is depressed, the  
message programmed in the 2nd line is  
printed.  
The [Enter] key depression results in  
that the input message is entered and  
displayed.  
Example of key operation)  
[] [] [] [] [] [] [] [3] [0] [1] [#]  
[3] [0] [3] [#] [3] [0] [4] [#] [3] [0] [3] [#] []  
[P] [E] [A] [C] [H] [] [D] [R] [I] [V] [E]  
[Enter]  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
The [Enter] key depression allows the  
ECR to enter the 3rd line message  
input mode. (The [C] key depression  
clears the message already  
programmed.) The 3rd line message  
is input.  
When the [Enter] key is depressed, the  
message programmed in the 3rd line is  
printed.  
The [Enter] key depression results in  
that the input message is entered and  
displayed.  
Example of key operation)  
[] [] [] [] [] [] [][] [P] [H] [O]  
[N] [E] [3] [1] [0] [#] [] [3] [0] [8] [#] [3] [0]  
[7] [#] [2] [1] [3] [#] [3] [0] [6] [#] [3] [0] [4]  
[#] [3] [0] [3] [#] [3] [0] [7] [#] [Enter]  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
The [Enter] key depression allows the  
ECR to enter the 4th line message  
input mode. (The [C] key depression  
clears the message already  
programmed.) The 4th line message is  
input.  
When the [Enter] key is depressed, the  
message programmed in the 4th line is  
printed.  
The [Enter] key depression results in  
that the input message is entered and  
displayed.  
Example of key operation)  
[Enter] (No message is input.)  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
NOTE: In the above example, characters except for alphabets are  
entered using the character code entry method.  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
STORE NAME  
1
TECSTORE  
2
1343 PEACH DRIVE  
3
PHONE: 87-6437  
0005 13:15TM  
6-58  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.9 Department Name Programming  
6.9  
Department Name Programming  
A maximum of 16 characters of department name is programmed here.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] then [Enter].  
2 NAMES” for various name programming is selected.  
1 DP KEY NAME” is selected.  
or  
Depress [2].  
Depress [2] or [Enter] key.  
Select a department of which name is  
to be programmed with the [] or []  
key.  
The department name already programmed is displayed.  
The ECR enters character input mode.  
[Enter]  
Input a department name.  
[Enter]  
A maximum of 16 one-byte or 8 two-byte characters are input.  
The department name is entered and printed.  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTE:  
A maximum of 16 one-byte characters or 8 two-byte characters can be entered. A combination of  
both types is also available.  
6-59  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.9 Department Name Programming  
3) Example  
To program “FOOD” as the name of Department 01.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
2 NAME” is selected.  
Depress the [2] or [Enter] key.  
1 DP KEY NAME” is selected.  
Depress the [1] or [Enter] key.  
When programming a name of another  
department, move the cursor on to a desired  
department with the [] or [] key, then  
depress the [Enter] key.  
Depress the [Enter] key.  
(Department 01 is selected.)  
The department name already programmed  
is displayed.  
The [C] key depression clears the  
department name already  
programmed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Input a desired name.  
Example of key operation)  
[F] [O] [O] [D] [Enter]  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
DP NAME  
01 FOOD  
0006 13:17TM  
6-60  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.10 Department Group Name Programming  
6.10 Department Group Name Programming  
In this operation, the name of each Department Group is programmed. Which Departments are linked to each  
Group has been set in the DEPARTMENT TABLE PROGRAMMING operation. A maximum of 15 department  
groups can be set.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
Main Menu  
ECR is being outside a sale and in SET mode.  
Depress [] then [Enter].  
or  
2 Names” is selected.  
Depress [2].  
Depress [] then [Enter].  
or  
2 DP GROUP NAME” is selected.  
Depress [2].  
Select a department group of which  
name is to be programmed with the []  
or [] key.  
The department group name already programmed is displayed.  
[Enter]  
Input a department group name.  
[Enter]  
The ECR enters character input mode.  
A maximum of 12 one-byte or 6 two-byte characters are input.  
The department group name is entered and printed.  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTE: A maximum of 12 one-byte characters or 6 two-byte characters can be entered. A combination of both  
types is also available.  
3) Example  
To program the following name on Department Group 1:  
Group 1  
F R E S H  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
(continued on the next page)  
6-61  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.10 Department Group Name Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
2 NAMES” is selected.  
Depress the [2] or [Enter] key.  
The cursor is moved on to “2 DP GROUP  
NAME”.  
Depress the [] key.  
2 DP GROUP NAME” is selected.  
Depress the [2] or [Enter] key.  
When programming a name of another  
department group, move the cursor on to a  
desired one with the [] or [] key, then  
depress the [Enter] key.  
Depress the [Enter] key.  
(Department Group 1 is selected.)  
The department group name already  
programmed is displayed.  
The [C] key depression clears the  
department group name already  
programmed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Input a desired name.  
Example of key operation)  
[Dbl] [F] [R] [E] [S] [H] [Enter]  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
GROUP  
FRESH  
01  
0007 13:19TM  
6-62  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.11 Cashier Name and Status Programming  
6.11 Cashier Name and Status Programming  
Cashier Name and Cashier Status for each cashier can be programmed here.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] then [Enter].  
2 NAMES” for various name programming is selected.  
or  
Depress [2].  
Depress [] twice then [Enter].  
3 CASHIER NAME” is selected.  
The cashier name already programmed is displayed.  
or  
Depress [3].  
Select a cashier to be programmed  
with the [] or [] key, then depress  
[Enter].  
The [Enter] key depression allows the ECR to enter the programming  
mode for a desired cashier. (Cashiers 1 to 8 are programmable.)  
The ECR enters character input mode.  
[Enter]  
Input a cashier name.  
[Enter]  
A maximum of 12 one-byte or 6 two-byte characters are input.  
The cashier name is entered and displayed.  
The ECR enters the cashier status input mode.  
[Enter]  
Select a cashier status with the [] or  
[] key, then depress the [] key to  
set/reset the status.  
The two statuses below are set/reset. (N: Reset, Y: Set)  
01 Training  
02 All MDR  
The programmed data is printed.  
[Enter]  
[End]  
*
This programming is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
*: Depress the [Rtn] key to program another cashier.  
6-63  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.11 Cashier Name and Status Programming  
NOTES:  
1. Cashiers 1 to 8 are programmed with the names “1CL” to “8CL” as default setting.  
2. For the name of each cashier, a maximum of 12 one-byte or 6 two-byte characters can be entered.  
A combination of both types is also available.  
3. Training entry status is available for every cashier.  
4. Prior to the change of cashier status (Normal cashier Training cashier, or Training cashier Normal  
Cashier), daily reports and GT reports of this cashier should be taken.  
3) Example  
To program the following cashier data.  
Cashier 1: JONES (cashier name), Training Cashier (status)  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
2 NAMES” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key twice.  
The cursor is moved on to “3 CASHIER  
NAME”.  
3 CASHIER NAME” is selected.  
Depress the [3] or [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
The cashier name already  
programmed is displayed.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
The [Enter] key depression allows the  
ECR to enter Cashier 1 programming  
mode menu.  
(To program a desired cashier, select  
the cashier with the [] key then  
depress the [Enter] key.)  
(continued on the next page)  
6-64  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.11 Cashier Name and Status Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
The [Enter] key depression allows the  
ECR to enter the cashier 1 name input  
mode. (The [C] key depression clears  
the name already programmed.) The  
cashier 1 name is input.  
Example of key operation)  
[J] [O] [N] [E] [S] [Enter]  
Number of programmed characters  
Number of programmable characters  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
The next [Enter] key depression  
allows the ECR to enter the cashier 1  
status input mode.  
Select the status of 01 TRAINING with  
the [] key.  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the Cashier 1 programming data is  
entered.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
CASHIER  
01  
#01  
#02  
JONES  
1
0008 13:21TM  
6-65  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.12 PLU Name Programming  
6.12 PLU Name Programming  
A maximum of 16 characters of PLU name is programmed here.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] then [Enter].  
2 NAMES” for various name programming is selected.  
or  
Depress [2].  
Depress the [] key three times then  
[Enter].  
or  
4 PLU (ITEM NO.) NAME” is selected.  
Depress [4].  
Select a PLU of which name is to be  
programmed with the [] or [] key.  
The PLU name already programmed is displayed.  
The ECR enters character input mode.  
[Enter]  
Input a PLU name.  
[Enter]  
A maximum of 16 one-byte or 8 two-byte characters are input.  
The PLU name is entered and printed.  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTE:  
A maximum of 16 one-byte characters or 8 two-byte characters can be entered. A combination of  
both types is also available.  
3) Example  
To program “Tomato” as the name of PLU Code No. 0001.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
(continued on the next page)  
6-66  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.12 PLU Name Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
Depress the [2] or [Enter] key.  
The cursor is moved on to “4 PLU (ITM NO.)  
NAME”.  
Depress the [] key three times.  
4 PLU (ITM NO.) NAME” is selected.  
Depress the [4] or [Enter] key.  
When programming a name of another PLU,  
move the cursor on to a desired PLU with the  
[] or [] key, then depress the [Enter] key.  
Depress the [Enter] key.  
(PLU Code No. 0001 is selected.)  
The PLU name already programmed is  
displayed.  
The [C] key depression clears the PLU  
name already programmed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Input a desired name.  
Example of key operation)  
[T] [A/a] [o] [m] [a] [t] [o] [Enter]  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
PLU NAME  
0001 Tomato  
0009 13:23TM  
6-67  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.13 Salesperson Name Programming  
6.13 Salesperson Name Programming  
By programming Salesperson here, the name of each salesperson can be programmed in a maximum of 12  
characters.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] then [Enter].  
2 NAMES” is selected.  
or  
Depress [2].  
Depress the [] key four times then  
[Enter] key.  
or  
5 SALESPERSON NAME” is selected.  
Depress [5].  
Select a salesperson of which name is  
to be programmed with the [] or []  
key.  
The salesperson name already programmed is displayed.  
The ECR enters character input mode.  
[Enter]  
Input a salesperson name.  
[Enter]  
A maximum of 12 one-byte or 6 two-byte characters are input.  
The salesperson name is entered and printed.  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTES:  
1. A maximum of 30 salesperson names can be set. The salesperson codes 1 to 30 are fixed.  
2. A maximum of 12 one-byte characters or 6 two-byte characters can be entered. A combination of both types  
is also available.  
6-68  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.13 Salesperson Name Programming  
3) Example  
To program “White” on Salesperson Code 01:  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
2 NAMES” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key four times.  
Depress the [5] or [Enter] key.  
The cursor is moved on to  
5 SALESPERSON NAME”.  
5 SALESPERSON NAME” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Depress the [Enter] key.  
(Salesperson 01 is selected.)  
The salesperson name already programmed  
is displayed.  
The [C] key depression clears the  
salesperson name already  
programmed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Input a desired name.  
Example of key operation)  
[W] [A/a] [h] [I] [t] [e] [Enter]  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
(continued on the next page)  
6-69  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.13 Salesperson Name Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
SALES PERSON  
01 White  
0010 13:25TM  
6-70  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.14 Financial Report Item Name Programming  
6.14 Financial Report Item Name Programming  
Item Names printed on Financial Report are programmed here. Many of them are also printed on sales receipts.  
Other Line Item Names will be programmed in 6.15 Print Line Item Name Programming.  
CONDITION  
After Financial Reset  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] then [Enter].  
2 NAMES” is selected.  
or  
Depress [2].  
Depress the [] key five times then  
[Enter] key.  
6 FINANCIAL ITM NAME” is selected.  
or  
Depress [6].  
Select a Financial item name of which  
The financial item name already programmed is displayed.  
name is to be programmed with the []  
or [] key.  
The ECR enters character input mode.  
[Enter]  
A maximum of 12 one-byte or 6 two-byte characters are input.  
Input a Financial item name.  
The financial item name is entered and printed.  
[Enter]  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTES:  
1. As for most items, a maximum of 12 regular-sized or 6 double-sized characters may be programmed for one  
item name.  
2. As shown in the table on the following pages, the standard program data are pre-programmed (which is  
auto-set after a RAM Clear). Therefore, program only the items that need to be changed.  
6-71  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.14 Financial Report Item Name Programming  
3) Example  
To program “NET GT” instead of “NET GT” for Item Code 2 (NET GT) all in double-sized characters.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
2 NAMES” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key five times.  
Depress the [6] or [Enter] key.  
The cursor is moved on to  
6 FINANCIAL ITM NAME”.  
6 FINANCIAL ITM NAME” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Depress the [] key, then depress the  
[Enter] key.  
(Item code 2 (“NET GT”) is selected.)  
The financial item name already  
programmed is displayed.  
The [C] key depression clears the  
financial item name already  
programmed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Input a desired name.  
Example of key operation)  
[Dbl] [N] [E] [T] [] [G] [T] [Enter]  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
(continued on the next page)  
6-72  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.14 Financial Report Item Name Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
FINANCIAL  
#002 NET GT  
0011 13:27TM  
Financial Report Item Name Table  
Item  
Code  
Item Name  
Standard Program  
1
Ground Total  
G T  
2
NET GT  
N
N
E
E
T
G
G
T
T
3
NEG GT  
G
4
Gross Sale  
G S  
5
Tax 1 (Add-on Tax 1)  
Tax 2 (Add-on Tax 2)  
Tax 3 (Add-on Tax 3)  
Tax 4 (Add-on Tax 4)  
Tax 5 (Add-on Tax 5)  
Tax 6 (Add-on Tax 6)  
Tax 7 (Add-on Tax 7)  
Tax 8 (Add-on Tax 8)  
Tax Total  
T
T
T
T
T
T
T
T
T
A
A
A
A
A
A
A
A
A
X
X
X
X
X
X
X
X
X
1
2
3
4
5
6
7
8
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
T
L
Net Sale with Tax  
% I (usually %+)  
N S  
% +  
%
V
D
-
% II (usually %-)  
-
.
Vendor Coupon  
C
S
P
.
P
C
N
Amount Discount  
Negative Depts. Total  
Special Round Fractions  
Net Sale (All-Media Sales)  
Cash Sales (AT/TL)  
Media 1 Sales (CHK)  
Media 2 Sales (CRT)  
Media 3 Sales (MISC)  
I
D
P
T
L
S
R
N
D
N S  
C
C
C
M
A
H
R
I
S
E
T
S
H
C
K
C
6-73  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.14 Financial Report Item Name Programming  
Financial Report Item Name Table (continued)  
Item  
Code  
Item Name  
Media 4 Sales (CPN)  
Standard Program  
26  
27  
28  
28  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
C
C
C
C
C
C
R
P
P
R
R
R
R
R
/
N
Media 5 Sales (Credit 1)  
T
T
T
T
T
A
T
T
T
T
T
L
L
L
L
L
1
2
3
4
5
Media 6 Sales (Credit 2)  
Media 7 Sales (Credit 3)  
Media 8 Sales (Credit 4)  
Media 9 Sales (Credit 5)  
Received-on-Account  
Paid-Out  
O
A
A
A
A
A
A
H
K
K
K
K
K
R
R
R
R
R
R
I
Cash-in-drawer  
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
M
M
M
M
M
M
C
C
C
C
C
C
C
C
C
C
C
C
C
S
S
S
S
S
S
E
H
H
H
H
H
H
C
C
C
C
C
C
I
D
U
U
U
U
U
I
Cash-in-drawer (Foreign Currency 1)  
Cash-in-drawer (Foreign Currency 2)  
Cash-in-drawer (Foreign Currency 3)  
Cash-in-drawer (Foreign Currency 4)  
Cash-in-drawer (Foreign Currency 5)  
Media 1-in-drawer (CHK)  
C
C
C
C
C
R
R
R
R
R
D
1
2
3
4
5
I
I
I
I
I
D
D
D
D
D
K
U
U
U
U
U
I
Cheque-in-drawer (Foreign Currency 1)  
Cheque-in-drawer (Foreign Currency 2)  
Cheque-in-drawer (Foreign Currency 3)  
Cheque-in-drawer (Foreign Currency 4)  
Cheque-in-drawer (Foreign Currency 5)  
Media 2-in-drawer (CRT)  
R
R
R
R
R
D
U
U
U
U
U
I
1
I
I
I
I
I
D
D
D
D
D
2
3
4
5
T
T
T
T
T
T
S
S
S
S
S
S
N
N
N
N
N
N
T
T
T
T
T
S
Credit-in-drawer (Foreign Currency 1)  
Credit-in-drawer (Foreign Currency 2)  
Credit-in-drawer (Foreign Currency 3)  
Credit-in-drawer (Foreign Currency 4)  
Credit-in-drawer (Foreign Currency 5)  
Media 3-in-drawer (MISC)  
C
C
C
C
C
R
R
R
R
R
D
U
U
U
U
U
1
2
3
4
5
I
I
I
I
I
D
D
D
D
D
C
C
C
C
C
C
MISC-in-drawer (Foreign Currency 1)  
MISC-in-drawer (Foreign Currency 2)  
MISC-in-drawer (Foreign Currency 3)  
MISC-in-drawer (Foreign Currency 4)  
MISC-in-drawer (Foreign Currency 5)  
Media 4-in-drawer (CPN)  
I
C
C
C
C
C
D
U
U
U
U
U
D
D
D
D
D
D
F
R
R
R
R
R
1
2
3
4
5
I
I
I
I
I
D
D
D
D
D
I
I
I
I
P
P
P
P
P
P
R
R
R
R
R
A
K
I
C
C
C
C
C
I
Coupon-in-drawer (Foreign Currency 1)  
Coupon-in-drawer (Foreign Currency 2)  
Coupon-in-drawer (Foreign Currency 3)  
Coupon-in-drawer (Foreign Currency 4)  
Coupon-in-drawer (Foreign Currency 5)  
Media 5-in-drawer (Credit 1)  
R
R
R
R
R
1
2
3
4
5
I
1
2
3
4
5
I
I
I
I
I
D
D
D
D
D
Media 6-in-drawer (Credit 2)  
I
Media 7-in-drawer (Credit 3)  
I
Media 8-in-drawer (Credit 4)  
I
Media 9-in-drawer (Credit 5)  
I
Cash-in-drawer Difference  
H
D
F
Media 1-in-drawer Difference  
I
6-74  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.14 Financial Report Item Name Programming  
Financial Report Item Name Table (continued)  
Item  
Code  
Item Name  
Media 2-in-drawer Difference  
Standard Program  
71  
72  
C
M
C
C
C
C
C
C
C
V
M
A
S
R
R
%
D
T
R
I
T
S
N
T
T
T
T
T
R
I
D
D
I
F
I
Media 3-in-drawer Difference  
Media 4-in-drawer Difference  
Media 5-in-drawer Difference  
Media 6-in-drawer Difference  
Media 7-in-drawer Difference  
Media 8-in-drawer Difference  
Media 9-in-drawer Difference  
Item Correct  
C
D
I
F
73  
P
R
R
R
R
R
O
O
I
F
I
74  
1
2
D
D
D
D
D
F
F
F
F
F
75  
I
76  
3
I
77  
4
I
78  
5
I
79  
R
D
C
80  
Void  
81  
Misc. Void  
S
L
V
D
D
82  
All Void  
L
V
N
83  
Store Coupon  
.
C
N
G
P
-
84  
Returned Merchandise  
Negative Mode Total  
%- on Line Items  
Amount Discount on Line Items  
Transfer Balance GT  
Transfer + GT  
T
E
-
85  
86  
87  
I
S
F
F
F
F
F
C
88  
R
R
R
R
R
B
B
B
X
A
X
A
X
A
X
A
X
A
X
A
X
A
X
A
A
T
L
89  
T
+
-
G
G
T
T
90  
Transfer – GT  
T
91  
Transfer + Daily  
T
+
-
92  
Transfer – Daily  
T
93  
PB (Previous Balance) Sales  
PB R/A (PB Paid)  
PB PO (PB Refunded)  
Taxable Total 1  
P
P
P
T
T
R
P
L
1
L
2
L
3
L
4
L
5
L
6
L
7
L
8
L
/
94  
A
95  
O
1
96  
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
T
97  
VAT 1 or Tax 1  
V
T
98  
Taxable Total 2  
2
3
4
5
6
7
8
T
99  
VAT 2 or Tax 2  
V
T
100  
101  
102  
103  
104  
105  
106  
107  
108  
109  
110  
111  
112  
113  
114  
115  
Taxable Total 3  
VAT 3 or Tax 3  
V
T
Taxable Total 4  
VAT 4 or Tax 4  
V
T
Taxable Total 5  
VAT 5 or Tax 5  
V
T
Taxable Total 6  
VAT 6 or Tax 6  
V
T
Taxable Total 7  
VAT 7 or Tax 7  
V
T
Taxable Total 8  
VAT 8 or Tax 8  
V
V
L
VAT Total  
N . N S  
Net Sale Without Tax  
Tax-exempt Customer  
VAT 1 or Tax 1 Exempt  
V
V
A
A
T
T
E
E
X
X
1
6-75  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.14 Financial Report Item Name Programming  
Financial Report Item Name Table (continued)  
Item  
Code  
Item Name  
VAT 2 or Tax 2 Exempt  
Standard Program  
116  
117  
118  
119  
120  
121  
122  
123  
124  
125  
126  
127  
128  
129  
130  
V
V
V
V
V
V
V
I
A
A
A
A
A
A
A
T
L
T
T
T
T
T
T
T
E
2
3
4
5
6
7
8
M
E
E
E
E
E
E
E
/
X
X
X
X
X
X
X
C
C
L
VAT 3 or Tax 3 Exempt  
VAT 4 or Tax 4 Exempt  
VAT 5 or Tax 5 Exempt  
VAT 6 or Tax 6 Exempt  
VAT 7 or Tax 7 Exempt  
VAT 8 or Tax 8 Exempt  
Sales Item Count per Customer  
Sales Amount per Customer  
No-Sale Counter  
U
U
E
S
S
T
N
C
C
V
M
/
O
L
S
A
S
I
A
R
I
[C] key Counter  
E
N
L
Consignment Counter  
Validation Counter  
O
A
.
G
C
N
T
C
T
R
R
Money Declaration Counter  
-- vacant --  
D
C
R
6-76  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.15 Print Line Item Name Programming  
6.15 Print Line Item Name Programming  
Print Line Item Names not listed in Section 6.14 Financial Report Item Name Programming can be  
programmed here.  
CONDITION  
OPERATION  
Anytime outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] then [Enter].  
2 NAMES” is selected.  
or  
Depress [2].  
Depress the [] key six times then  
[Enter] key.  
or  
7 PRINT ITEM NAME” is selected.  
Depress [7].  
Select a print item name of which name  
is to be programmed with the [] or []  
key.  
The print line item name already programmed is displayed.  
The ECR enters character input mode.  
NOTE 1 below  
[Enter]  
Input a print line item name.  
[Enter]  
The print line item name is entered and printed.  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTES:  
1. The maximum number of characters programmable for each item are shown in the table on the following  
pages. Please note that some items require their name entries as one set. The maximum number of  
characters in the table shows the capacity in one-byte characters. A two-byte character occupies two one-  
byte characters’ space. (Also refer to CHARACTER ENTRIES at the beginning of this chapter.)  
2. As shown in the table on the following pages, the standard program data are preprogrammed which is auto-  
set after a RAM Clear). Therefore, program only the items that need to be changed.  
6-77  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.15 Print Line Item Name Programming  
3) Example  
To program the amount mark “€” in Item Code 7: (The amount mark has not been preset as the standard  
program data).  
Meanwhile, the names of the other items in the Item Code 7 should remain unchanged as the standard  
program data (i.e. “@” for Unit Price Symbol and “ITEM” for Sale Item Count Symbol).  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
2 NAMES” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key six times.  
Depress the [7] or [Enter] key.  
The cursor is moved on to  
7 PRINT ITEM NAME”.  
7 PRINT ITEM NAME” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Depress the [] key six times, then  
depress the [Enter] key.  
(Item code 7 (“@ ITEM ”) is selected.)  
The print line item name already  
programmed is displayed.  
The [C] key depression clears the print  
line item name already programmed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Input a desired name.  
Example of key operation)  
400[#] 900[#] [I] [T] [E] [M] [] [Enter]  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
(continued on the next page)  
6-78  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.15 Print Line Item Name Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
PRINT NAME  
#007 @ITEM  
0012 13:29TM  
Print Line Item Name Table  
Max. Number of Characters  
Item  
Code  
Item Name or Application  
Subtotal in transactions  
Cash Tendered in transactions  
Sale Total of each transaction  
Change due in transactions  
Cash Refunded  
Standard Program  
1
2
3
4
5
6
S
C
T
C
C
-
U
A
O
H
A
T
B
T
T
A
S
O
I
T
E
A
N
H
T
T
L
8
8
8
8
8
8
7
1
1
4
1
6
2
2
2
2
---  
8
8
8
8
8
4
4
N
L
G
D
E
Negative Department Total  
The following items must be set together. (NOTE 1)  
A
E
L
M
@
Unit Price Symbol  
Amount Mark (€, $,etc.)  
Sale Item Count Symbol on Receipt  
Unit Price Symbol on Quantity Extension  
The following items must be set together. (NOTE 2)  
7
8
#
C
L
T
M
Register No. Symbol  
Cashier/Clerk Symbol  
Time Symbol  
Customer Count (on reports)  
-- vacant --  
Previous Balance (Credit) (NOTE 5)  
Previous Balance (Debit) (NOTE 5)  
Transferred Amount in Charge Posting  
Item Correct  
The following items must be set together.  
ON portion of Training ON/OFF  
OFF portion of Training ON/OFF  
9
C
U
10  
11  
12  
13  
14  
P B +  
P B -  
N
C
E
O
O
W
R
N
B
A
O
L
F
R
F
15  
6-79  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.15 Print Line Item Name Programming  
Print Line Item Name Table (continued)  
Max. Number of Characters  
Item  
Code  
Item Name or Application  
Standard Program  
VAT symbol (VAT 1 to VAT8)  
VAT 1 symbol  
A
B
C
D
E
F
G
H
8
1
VAT 2 symbol  
1
VAT 3 symbol  
1
16  
VAT 4 symbol  
1
VAT 5 symbol  
1
VAT 6 symbol  
1
VAT 7 symbol  
1
VAT 8 symbol  
1
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
-- vacant --  
-- vacant --  
Post-issue Receipt Header  
PLU Symbol (when no name is programmed for the PLU)  
---  
---  
10  
3
C
P
T
O
L
X
P
U
B
Y
L
Taxable Total  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
Sunday, Monday (as part of the date print line)  
T
L
8
---  
---  
---  
---  
---  
---  
8
4
4
8
4
S
T
U
U
N
E
M
W
F
O
E
N
D
I
28  
29  
30  
Sunday  
Monday  
Tuesday, Wednesday (as part of the date print line)  
Tuesday  
Wednesday  
Thursday, Friday (as part of the date print line)  
Thursday  
4
8
4
T
H
U
R
Friday  
4
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
Saturday (as part of the date print line)  
Training ON/OFF operation, Cashier Report  
Cashier Sign ON  
Cashier Sign OFF  
-- vacant --  
S
R
I
A
A
G
G
T
I
N
N
4
T
S
S
N
I
O
O
N
N
F
G
F
10  
10  
10  
---  
---  
---  
8
I
-- vacant --  
-- vacant --  
% calculation on Additional Item Entries after Subtotal and % entries  
G
R
R
E
P
C
.
S
I
T
P
-- vacant --  
Receipt Buffer  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
---  
12  
E
T
B
U
F
---  
---  
---  
---  
---  
---  
---  
---  
-- vacant --  
Foreign Currency 1 (for Sales Entry, Programming,  
Program Data Read)  
50  
C
U
R
1
12  
6-80  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.15 Print Line Item Name Programming  
Print Line Item Name Table (continued)  
Max. Number of Characters  
Item  
Code  
Item Name or Application  
Standard Program  
Foreign Currency 2 (for Sales Entry, Programming,  
Program Data Read)  
Foreign Currency 3 (for Sales Entry, Programming,  
Program Data Read)  
Foreign Currency 4 (for Sales Entry, Programming,  
Program Data Read)  
Foreign Currency 5 (for Sales Entry, Programming,  
Program Data Read)  
51  
C
C
C
C
U
U
U
U
R
R
R
R
2
3
4
5
12  
12  
12  
12  
52  
53  
54  
55  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
100  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
NET Total  
VAT/TAX  
Consignment  
NET TL1  
NET TL2  
NET TL3  
NET TL4  
---  
---  
---  
---  
---  
---  
12  
8
N
V
C
N
N
N
N
N
N
N
N
E
A
O
E
E
E
E
E
E
E
E
T
T
N
T
T
T
T
T
T
T
T
T
L
S
I
G
L
L
L
L
L
L
L
L
N
1
2
3
4
5
6
7
8
M
E
N
T
12  
12  
12  
12  
12  
12  
12  
12  
12  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
T
T
T
T
T
T
T
T
NET TL5  
NET TL6  
NET TL7  
NET TL8  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
6-81  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.15 Print Line Item Name Programming  
NOTES:  
1. The standard program data for the Amount Mark in Item Code 7 is set with a blank after a RAM Clear.  
When the specific Amount Mark for the domestic currency is required on sales receipts (such as £, ¥, $), you  
must program the entire contents of Item Code 7.  
2. The Cashier Symbol to be set in Item Code 8 (“CL” in Standard Program) will be used to print the 2-digit  
Cashier ID code on a validation slip. On receipts, the name of each cashier programmed in the CASHIER  
NAME AND STATUS PROGRAMMING operation will be printed.  
3. If no programming is performed for an item, the name in the Standard Program column will automatically be  
active. Therefore, program only the items that require changes from the standard program data.  
4. The following are other auto-preset data table and other fixed data table for printing various symbols, items,  
or descriptors.  
Other Auto-Preset Data (programmable)  
The following data are automatically preset in the program memory. However, when the corresponding  
items’ names are programmed in the corresponding setting, the programmed name will be active instead of  
the preset data.  
Item  
Department Group  
Department  
Cashier Symbol  
Salesperson Symbol  
Preset Data  
Remarks  
GP  
DP  
CL  
GP01 to GP15  
DP01 to DP99  
1CL to 8CL  
SP  
SP01 to SP99  
Other Fixed Data (unchangeable)  
Item  
Fixed Data  
Remarks  
RAM Clear  
RAM-C  
Data Clear  
DATA-C  
Status Clear  
STATUS-C  
Program Mode Symbol  
System Option Address  
Percent Rate Symbol  
Non-add Number Symbol  
Taxable Status Mark  
Negative Amount Mark  
Quantity Extension Mark  
P
#
%
#
T
-
X
6-82  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.16 Display item Name Programming  
6.16 Display Item Name Programming  
Display Item Name to be displayed on the LCD display can be programmed here. (Max. 16 characters)  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] then [Enter].  
2 NAMES” is selected.  
or  
Depress [2].  
Depress the [] key seven times then  
[Enter] key.  
or  
8 DISPLAY ITEM NAME” is selected.  
Depress [8].  
Select a display item name of which  
name is to be programmed with the []  
or [] key.  
The display item name already programmed is displayed.  
The ECR enters character input mode.  
[Enter]  
Input a display item name.  
[Enter]  
A maximum of 16 one-byte or 8 two-byte characters are input.  
The display item name is entered and printed.  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTES:  
1. A maximum of 16 characters can be programmed as the name or message for each Item Code.  
2
As shown in the table on the following page, the standard program data is pre-programmed for each Item  
Code. (which is auto-set after a RAM Clear). Therefore, program only the name or message that needs to  
be changed.  
6-83  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.16 Display item Name Programming  
Display Item Name Table  
Item  
Application  
Code  
Standard Program  
1
2
3
-- vacant --  
Signed-OFF condition  
(in REG, MGR, or - mode)  
Balance due after a short tendered  
L
O
G
T
O
T
A
L
4 to 9 -- vacant --  
10  
11  
12  
Price Shift 1 Operation  
Price Shift 2 Operation  
Price Shift 3 Operation  
P
P
P
R
R
R
I
I
I
C
C
C
E
E
E
S
S
S
H
H
H
I
I
I
F
F
F
T
T
T
1
2
3
13 to 43 -- vacant --  
44  
45  
46  
47  
48  
49  
50  
Slip Printer Connection Check  
-- vacant --  
VAT Total  
Preset Price Open  
Listing Capacity Open  
[OPEN] Key Depression  
Multiplication  
S
L
I
P
D
I
S
A
C
L
O
N
N
E
C
T
?
V
P
L
O
X
A
R
C
P
T
.
T
P
P
O
E
E
T
N
N
O
O
N
E
51 to 53 -- vacant --  
[TX1/M] Key Depression  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
T
T
T
T
T
T
T
T
X
X
X
X
X
X
X
X
1
2
3
4
5
6
7
8
/
/
/
/
/
/
/
/
M
M
M
M
M
M
M
M
[TX2/M] Key Depression  
[TX3/M] Key Depression  
[TX4/M] Key Depression  
[TX5/M] Key Depression  
[TX6/M] Key Depression  
[TX7/M] Key Depression  
[TX8/M] Key Depression  
-- vacant --  
-- vacant --  
SET, BLIND mode  
X mode  
Z mode  
REG mode  
MGR mode  
- mode  
Time Setting (hour)  
Time Setting (minute)  
Item Symbol  
-- vacant --  
-- vacant --  
Diag.  
S
E
T
X
Z
G
R
-
R
M
E
h
m
t
E
G
G
R
i
e
m
G
D
P
E
T
I
A
-
Key Status Setting (PB-)  
Key Status Setting (EX)  
Key Status Setting (TRF)  
YN Symbol  
Key Status Setting (1’st PRICE)  
Key Status Setting (2’nd PRICE)  
Key Status Setting (3’rd PRICE)  
B
X
R
F
Y
N
1
2
3
s
n
r
t
d
d
P
P
P
R
R
R
I
I
I
C
C
C
E
E
E
83 to 100 -- vacant --  
6-84  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.16 Display item Name Programming  
3) Example  
To program “BALANCE DUE” instead of standard program data “TOTAL” for Item Code 3.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
2 NAMES” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key seven times.  
Depress the [8] or [Enter] key.  
The cursor is moved on to  
8 DISPLAY ITEM NAME”.  
8 DISPLAY ITEM NAME” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Depress the [] key twice, then  
depress the [Enter] key.  
(Item code 3 (“TOTAL”) is selected.)  
The display item name already programmed  
is displayed.  
The [C] key depression clears the  
display item name already  
programmed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Input a desired name.  
Example of key operation)  
[B] [A] [L] [A] [N] [C] [E] [] [D] [U] [E]  
[Enter]  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
(continued on the next page)  
6-85  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.16 Display item Name Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
DISPLAY NAME  
#003 BALANCE DUE  
0013 13:31TM  
6-86  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.17 Error Item Name Programming  
6.17 Error Item Name Programming  
Error item names to be displayed on the LCD display are programmed here. A maximum of 16 one-byte  
characters by 2 lines can be programmed.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] then [Enter].  
2 NAMES” is selected.  
or  
Depress [2].  
Depress the [] key eight times then  
[Enter] key.  
or  
9 ERROR ITEM NAME” is selected.  
Depress [9].  
Select an error code of which error item  
name is to be programmed with the []  
or [] key.  
The error item name already programmed is displayed.  
The ECR enters character input mode.  
[Enter]  
Input an error item name.  
[Enter]  
A maximum of 16 one-byte characters are input.  
The error item name is entered and printed.  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTES:  
1. A maximum of 16 one-byte characters can be programmed as the error item name for each error code.  
Enter all the characters in regular size.  
2
As shown in the table on the following pages, the standard program data are preprogrammed (which is auto-  
set after a RAM Clear). Therefore, program only the error item names that need to be changed.  
6-87  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.17 Error Item Name Programming  
3) Example  
To program “CALL MANAGER” instead of standard program data “MANAGER REQUIRED” for Error Code 3.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
2 NAMES” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key eight times.  
Depress the [9] or [Enter] key.  
The cursor is moved on to  
9 ERROR ITEM NAME”.  
9 ERROR ITEM NAME” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Depress the [] key twice, then  
depress the [Enter] key.  
(Error Code 3 (“MANAGER  
REQUIRED”) is selected.)  
The error item name already programmed is  
displayed.  
The [C] key depression clears the error  
item name already programmed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Input a desired name.  
Example of key operation)  
[C] [A] [L] [L] [] [M] [A] [N] [A] [G] [E] [R]  
[Enter]  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
(continued on the next page)  
6-88  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.17 Error Item Name Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
ERROR MSG  
003 CALL MANAGER  
0014 13:33TM  
Error Code and Error Item Name Table  
Error  
Code  
Content or Cause of Error  
Standard Program  
1
2
3
4
5
6
O
M
P
A
E
N
R
A
A
T
I
O
N
E
R
U
R
I
O
R
R
E
Operation or Key Sequence Error  
G
E
R
R
E
Q
D
Manager Intervention Required  
-- vacant --  
7
8
9
C
C
L
O
M
S
P
E
U
D
S
R
O
A
R
W
Y
E
R
C
Drawer-Close Compulsory Error  
Code Entry Compulsory Error  
-- vacant --  
O
L
O
D
E
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
-- vacant --  
-- vacant --  
M
P
C
P
I
S
C
C
E
G
E
M
E
A
R
M
R
M
R
R
O
E
O
E
R
R
R
R
Other Miscellaneous Errors  
File Receive Error (with PC feature)  
Undefined Code or Code Duplicated Error  
Programming Error  
-- vacant --  
C
O
R
O
R
R
R
O
O
R
R
D
O
-- vacant --  
-- vacant --  
6-89  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.17 Error Item Name Programming  
Error Code and Error Item Name Table (continued)  
Error  
Content or Cause of Error  
Limit Over Warning  
Standard Program  
Code  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
D
R
A
W
E
R
L
I
M
I
T
(in Media Pick Up)  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
C
C
C
O
O
O
N
M
M
S
P
P
I
U
U
G
L
L
N
S
S
M
O
O
E
R
R
N
Y
Y
T
Consignment Print Compulsory Error  
Endorsement Print Compulsory Error  
-- vacant --  
S
L
I
P
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
P
C
H
A
R
O
R
E
P
E
V
E
A
E
C
E
C
D
R
E
R
E
E
P
O
P
P
N
T
P
T
E
D
E
Receipt Printer Paper Out  
Receipt Cover Open  
Journal Paper Retainer Open  
Printer Head Temperature Error  
Printer Head Voltage Error  
Journal Printer Paper Out  
-- vacant --  
I
N
O
R
O
L
I
O
N
J
P
U
E
R
R
N
R
A
O
L
R
H
V
P
E
O
A
A
L
D
T
E
T
E
E
E
M
N
F
A
R
G
E
R
U
I
O
R
N
R
N
E
P
D
J
A
L
S
L
I
P
O
F
Slip printer is offline status.  
6-90  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.17 Error Item Name Programming  
Error Code and Error Item Name Table (continued)  
Content or Cause of Error Standard Program  
Error  
Code  
81  
82  
S
L
I
P
P
A
P
E
R
O
U
T
Slip Printer Paper Out  
83  
84  
-- vacant --  
85  
86  
-- vacant --  
87  
88  
-- vacant --  
89  
90  
-- vacant --  
91  
92  
-- vacant --  
93  
94  
95  
96  
S
T
C
O
M
P
[ST] Key Entry Compulsory error  
-- vacant --  
97  
98  
-- vacant --  
99  
-- vacant --  
100  
101  
102  
103  
104  
-- vacant --  
S
S
T
A
A
O
E
H
V
A
I
L
L
E
E
A
D
T
T
H
S
S
L
P
-
E
P
O
R
S
P
L
O
R
Y
L
N
O
C
I
O
B
M
I
P
T
Salesperson Entry Compulsory Error  
105 Salesperson Sign-ON Prohibit Error  
H
during a sale  
106  
107  
108  
109  
110  
111  
112  
113  
114  
115  
116  
T
N
_
N
O
Total Only Error  
T
E
E
E
I
R
N
N
N
/
N
P
P
P
P
Y
O
O
O
O
Tender Only Error  
S
O
C
F
D
D
G
A
R
R
R
R
H
H
H
H
I
I
I
I
B
B
B
B
I
I
I
I
T
T
T
T
Short Tendering Prohibition Error  
Over Tendering Prohibition Error  
No-Sale Exchange Prohibition Error  
_
S
N
117 Finalization of the R/A entry is  
R
prohibited.  
118  
119  
120  
121  
122  
123  
124  
125  
126  
127  
128  
129  
130  
131  
132  
-- vacant --  
N
E
G
A
D
T
I
V
E
N
U
M
B
E
R
Negative Balance Error  
-- vacant --  
-- vacant --  
M
C
D
O
R
N
C
I
O
T
M
I
P
MDR Compulsory Error  
Condition Error  
-- vacant --  
O
N
E
R
R
O
R
6-91  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.17 Error Item Name Programming  
Error Code and Error Item Name Table (continued)  
Content or Cause of Error Standard Program  
-- vacant --  
Error  
Code  
133  
134  
135  
136  
137  
138  
139  
140  
141  
142  
143  
144  
145  
146  
147  
148  
149  
150  
-- vacant --  
-- vacant --  
-- vacant --  
P
P
N
R
R
O
I
O
C
H
P
E
I
R
I
I
C
N
T
E
P
P
U
E
I
T
R
N
Price Input Prohibition Error  
No price is input.  
Key Mode Change Error  
-- vacant --  
B
I
R
P
O
U
R
T
M
O
D
E
-
C
H
R
O
H
I
B
I
T
-- vacant --  
151 to  
200  
-- vacant --  
6-92  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.18 Read/Reset Report Name Programming  
6.18 Read/Reset Report Name Programming  
Read/Reset Report Names are programmed here. A maximum of 12 one-byte characters can be programmed.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] then [Enter].  
2 NAMES” is selected.  
or  
Depress [2].  
Depress the [] key nine times then  
[Enter] key.  
or  
0 X/Z REPORT NAME” is selected.  
Depress [0].  
Select an X/Z report No. of which report  
name is to be programmed with the []  
or [] key.  
The X/Z report name already programmed is displayed.  
The ECR enters character input mode.  
[Enter]  
Input an X/Z report name.  
[Enter]  
A maximum of 12 one-byte characters are input.  
The X/Z report name is entered and printed.  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTES:  
1. Enter all characters in regular size. In actually printing on reports, they will be printed in all double-sized  
characters.  
2. As shown in the table on the following pages, the standard program data is preprogrammed (which is auto-  
set after a RAM Clear). Therefore, program only the report names that need to be changed.  
6-93  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.18 Read/Reset Report Name Programming  
3) Example  
To program “X_DP_PROFIT” instead of standard program data “X_PROFIT” for Report No. 21.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 NAMES”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key.  
2 NAMES” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key nine times.  
Depress the [0] or [Enter] key.  
The cursor is moved on to  
0 X/Z REPORT NAME”.  
0 X/Z REPORT NAME” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Depress the [] key twenty times, then  
depress the [Enter] key.  
(Report No. 21 (“X_PROFIT”) is  
selected.)  
The report name already programmed is  
displayed.  
The [C] key depression clears the  
report name already programmed.  
Numbers of programmed characters and of  
programmable characters are displayed on  
the 7-segment numeric display.  
Input a desired name.  
Example of key operation)  
[X] 515 [#] [D] [P] 515 [#] [P] [R] [O] [F] [I]  
[T] [Enter]  
When the [Enter] key is depressed, the  
programmed data is printed.  
The [Enter] key depression results in  
that the input name is entered and  
displayed.  
(continued on the next page)  
6-94  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.18 Read/Reset Report Name Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
REPORT NAME  
#21  
X_DP_PROFIT  
0015 13:35TM  
Read/Reset Report Name Table  
X:  
Z:  
GTX:  
GTZ:  
Daily Read  
Daily Reset  
GT Read  
GT Reset  
Report  
Report  
No.  
Type  
Standard Program  
1
2
3
4
5
X
Z
GTX  
GTZ  
X
X
Z
G
G
X
Z
G
G
X
Z
G
G
X
Z
_
_
T
T
_
_
T
T
_
_
T
T
_
_
F
F
X
Z
C
C
X
Z
C
C
X
Z
S
S
I
I
N
N
I
A
A
N
N
R
R
L
N
N
A
A
K
K
E
E
K
K
E
E
E
E
C
C
N
N
I
I
C
C
A
A
I
L
L
A
A
Financial  
F
F
L
L
_
_
L
L
_
_
L
L
L
L
I
I
E
E
C
C
E
E
C
C
S
S
6
Z
All Cashier  
7
GTX  
GTZ  
X
R
R
K
K
8
9
10  
L
R
R
L
L
P
P
Z
Individual Cashier  
11  
GTX  
GTZ  
X
R
R
R
R
K
K
S
S
12  
13  
O
O
N
N
All Salesperson  
14  
Z
15  
16  
17  
18  
-- vacant --  
19  
20  
6-95  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.18 Read/Reset Report Name Programming  
Read/Reset Report Name Table (continued)  
X:  
Z:  
GTX:  
GTZ:  
Daily Read  
Daily Reset  
GT Read  
GT Reset  
Report  
No.  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
Report  
Type  
Standard Program  
X
GTX  
X
G
_
T
P
X
R
_
O
P
F
R
I
O
T
F
Department Gross Profit  
I
T
-- vacant --  
X
Z
X
Z
GTX  
GTZ  
X
Z
X
Z
G
G
_
_
_
_
T
H
H
D
D
X
Z
O
O
P
P
_
U
U
_
_
D
D
R
R
A
A
P
P
L
L
L
L
_
_
Y
Y
L
L
A
A
Hourly Range  
All Department  
L
L
L
L
T
_
-- vacant --  
All Media Sales and Cash-in Drawer  
All PLU  
X
X
Z
X
X
Z
_
_
_
M
P
P
E
L
L
D
U
U
I
_
_
A
A
A
L
L
L
L
-- vacant --  
X
Z
X
Z
_
_
P
P
L
L
U
U
_
_
Z
Z
O
O
N
N
E
E
Zone PLU  
-- vacant --  
X
Z
X
Z
_
_
M
M
D
D
R
R
Money Declaration  
-- vacant --  
6-96  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.18 Read/Reset Report Name Programming  
Read/Reset Report Name Table (continued)  
X:  
Z:  
GTX:  
GTZ:  
Daily Read  
Daily Reset  
GT Read  
GT Reset  
Report  
No.  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
Report  
Type  
Standard Program  
Enforced Clear of Hold Condition  
H
O
L
D
_
C
A
N
C
E
L
-- vacant --  
X
Z
GTX  
GTZ  
X
Z
G
G
_
_
T
T
F
F
X
Z
I
I
_
_
N
N
F
F
C
C
I
A
A
N
N
L
L
C
C
+
+
L
L
D
D
+
P
P
D
D
Financial + All Department  
P
P
I
+
-- vacant --  
6-97  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.19 Department Table Programming  
6.19 Department Table Programming  
For each department, memory opening, and department various statuses settings are performed here.  
To change the positive/negative status:  
After Department and PLU Daily and GT Resets  
To change any other programmed data or to newly program departments:  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode  
Main Menu  
Depress [] twice then [Enter].  
3 DP/PLU” for Department/PLU table programming is selected.  
or  
Depress [3].  
1 DP” is selected.  
Depress [1] or [Enter] key.  
1 DP SETTING” is selected.  
Depress [1] or [Enter] key.  
Select a department to be programmed with  
the [] or [] key, then depress [Enter].  
A department to be programmed is selected.  
The ECR enters detailed setting mode for department.  
Department Group No. Setting (See *1.)  
Preset Price Setting (See *2.)  
[Enter]  
Input a Group No. (01 to15), then depress  
[Enter].  
Input a preset price, then depress [Enter].  
Select a department status with the [] or  
[] key, then depress the [] or [] key to  
set/reset the status. After that, depress  
[Enter].  
Department Status Setting (See *3.)  
Input a VAT/Add-on tax status code (max. 8  
VAT/Add-on Tax Status Setting (See *4.)  
High Amount Limit Setting (See *5.)  
Low Amount Limit Setting (See *6.)  
Gross Profit Rate Setting (See *7.)  
digits), then depress [Enter].  
Input a High Amount Limit (max. 7 digits),  
then depress [Enter].  
Input a Low Amount Limit (max. 7 digits),  
then depress [Enter].  
Input a Gross Profit Rate (0,01 to 100,00%),  
then depress [Enter].  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
6-98  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.19 Department Table Programming  
*1: Department Group No.  
Input a department group code (2 digits: 01 to 15), then depress the [Enter] key.  
To cancel a department group, input 0 then depress the [Enter] key.  
All departments can be programmed in a group. Negative departments are added to the group total.  
*2: Preset Price  
For a preset department (preset-price department), enter a maximum of 6-digit price, and depress the  
[Enter] key.  
1 to 999999 (result: 0,01 to 9999,99)  
A zero-price (0,00) may be preset by entering 0 in the above operation.  
When no numeric value is entered and the [Enter] key is simply depressed, the department will be an  
open department (open-price department).  
*3: Department Status  
The status ON or OFF is selected with the [] and [] keys.  
The status change between positive and negative should be performed after performing a  
department/PLU daily and GT resets.  
The following shows each department status.  
Status  
Code  
Selective Status  
ON (Y)  
Item  
OFF (N)  
Itemized  
1
2
3
4
5
6
7
8
Single-item or Itemized Receipt  
-- vacant --  
Positive or Negative Department  
-- vacant --  
Single-item  
Negative  
Positive  
-- vacant --  
-- vacant --  
-- vacant --  
-- vacant --  
*4: VAT or Add-on Tax Status  
Tax type should be selected from either “VAT” or “ADD-ON TAX” by the system option.  
Enter one- to eight-digit status codes for applicable VAT or Add-on Tax.  
[Enter]  
VAT or Add-on Tax Status Type  
0: Non-VAT or Non-taxable  
1: VAT 1 or Tax 1  
2: VAT 2 or Tax 2  
(More than one code can be entered for  
3: VAT 3 or Tax 3  
combining Tax 1 to Tax 8 taxable statuses.  
4: VAT 4 or Tax 4  
For example, enter 12 to select VAT 1 and VAT  
5: VAT 5 or Tax 5  
2 (or Tax 1 and Tax 2) taxable statuses.)  
6: VAT 6 or Tax 6  
7: VAT 7 or Tax 7  
8: VAT 8 or Tax 8  
A combination of VAT and Add-on tax statuses is not possible.  
6-99  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.19 Department Table Programming  
*5: High Amount Limit  
Enter a maximum of 7 digits to be set as the high amount to be locked out.  
Example) To prohibit any amount equal to or larger than 40,00:  
4000 [Enter]  
(Allows any amount equal to or smaller than 39,99.)  
NOTES:  
1. To cancel the preset limit (i.e. to allow any amount), input 0.  
2. The limit amount set here will be applied to entries in REG mode only, but not in MGR or - mode.  
3. Zeros must be entered as all the digits other than the highest digit. If any other value is entered, it will be  
regarded as a zero.  
Example) Entering 4001 to 4999 will all result in setting 4000.  
*6: Low Amount Limit  
Enter a maximum of 7 digits to be set as the low amount limit.  
Example) To prohibit any amount smaller than 4,00:  
400 [Enter]  
(Prohibits any amount smaller than 4,00.)  
NOTES:  
1. To cancel the preset limit (i.e. to allow any amount), input 0.  
2. The limit amount set here will be applied to entries in REG mode only, but not in MGR or - mode.  
3. Zeros must be entered as all the digits other than the highest digit. If any other value is entered, it will be  
regarded as a zero.  
Example) Entering 401 to 499 will all result in setting 400.  
*7: Gross Profit Rate  
Enter the gross profit rate of the department in a maximum of 3 integer digits and 2 decimal digits.  
[Enter]  
or  
[ • ]  
[Enter]  
0 to 100 (%)  
0,01 to 99,99 (%)  
The calculated gross profit will be outputted to the DEPARTMENT GROSS PROFIT REPORT.  
The fraction resulted from the profit calculation will be discarded.  
To cancel the gross profit rate once set, input 0 in place of a specific rate before [Enter]. The  
department whose gross profit rate has thus been cancelled will not be outputted in the GROSS PROFIT  
REPORT.  
3) Example  
To program the following Department Data  
Department Code:  
Department Group No.:  
Preset Price:  
01  
01  
Open  
Department Status:  
Tax Status:  
HALO:  
Single-item  
VAT 1 and VAT 2  
€40,00  
€4,00  
LALO:  
Gross Profit Rate:  
10,00%  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “3 DP/PLU”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
(continued on the next page)  
6-100  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.19 Department Table Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
3 DP/PLU” is selected.  
Depress the [3] or [Enter] key.  
1 DP” is selected.  
Depress the [1] or [Enter] key.  
1 DP SETTINGS” is selected.  
Depress the [1] or [Enter] key.  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Depress the [Enter] key to select  
Department 01.  
*1: see NOTE below  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 01 (or 1), then depress the  
[Enter] key.  
(Department Group No. 01 is set.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Depress the [Enter] key.  
(The open-price is set.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
The [Enter] key depression allows the  
ECR to enter Department Status  
setting menu.  
(continued on the next page)  
6-101  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.19 Department Table Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Move the cursor on to a desired status  
setting with the [] or [] key.  
The [] key depression results in that the  
status is changed from N to Y.  
Depress the [] key then the [Enter]  
key.  
(The status of SINGLE-ITEM DP is  
selected.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 12, then depress the [Enter] key.  
(VAT/Add-on tax statuses 1 and 2 are  
set.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 4000, then depress the [Enter]  
key.  
(High amount limit €40,00 is set.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 400, then depress the [Enter]  
key.  
(Low amount limit €4,00 is set.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 10, then depress the [Enter] key.  
(Gross Profit Rate 10% is set.)  
(continued on the next page)  
6-102  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.19 Department Table Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
Depress the [Rtn] key.  
The display returns to the Department  
Setting screen. Move the cursor on to  
another desired department with the  
[] or [] key, then depress the [Enter]  
key.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
DP  
DP01  
01  
#01  
#02  
#03  
#04  
#05  
#06  
#07  
01  
1
12  
40,00  
4,00  
10%  
0016 13:37TM  
NOTE:  
(1) Opening the department memory  
After performing a RAM Clear, the department memory on the standard keyboard will be open  
automatically.  
On the screen *1, the department can be open by entering a department code and the [Enter] key.  
(2) Closing the department memory  
On the screen *1, the department is closed by entering the [Del] key, department code, and the [Enter]  
key.  
Condition: After Department daily/GT reset, Financial Daily/GT reset, and PLU reset  
6-103  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.20 Department Preset Price Setting or Changing  
6.20 Department Preset Price Setting or Changing  
The preset price of each department may be set in the DEPARTMENT TABLE PROGRAMMING already  
described. However, in setting or changing the price only but not other programmed data, the following operation  
will be more convenient.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
3 DP/PLU” for Department/PLU table programming is selected.  
1 DP” is selected.  
Main Menu  
Depress [] twice then [Enter].  
or  
Depress [3].  
Depress [1] or [Enter] key.  
Depress [] then [Enter].  
2 UNIT PRICE” is selected.  
or  
Depress [2].  
Select a department of which unit price  
is to be preset with the [] or [] key.  
Max. 6 digits (0 to 999999) (See NOTE below.)  
Input a unit price value.  
The department preset price is entered and printed.  
[Enter]  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE: When inputting 0 then depressing the [Enter] key, a zero price will be set to the department. If none of  
unit price value is input then the [Enter] key is depressed, the department will be open (i.e. open-price  
department).  
3) Example  
To preset the price €1,00 on Department 1 (FOOD):  
Operation  
LCD Display  
Remarks  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
The cursor is moved on to “3 DP/PLU”.  
(continued on the next page)  
6-104  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.20 Department Preset Price Setting or Changing  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
3 DP/PLU” is selected.  
Depress the [3] or [Enter] key.  
1 DP” is selected.  
Depress the [1] or [Enter] key.  
Depress the [] key.  
The cursor is moved on to “2 UNIT PRICE”.  
Depress the [2] or [Enter] key.  
2 UNIT PRICE” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Input 100 for the preset price of  
Department 1 (FOOD).  
When the [Enter] key is depressed, the  
programmed data is printed.  
Depress the [Enter] key.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
DP PRICE  
01 FOOD  
1,00@  
0017 13:39TM  
6-105  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.21 Department Listing Capacity (LC) Programming  
6.21 Department Listing Capacity (LC) Programming  
The High Amount to be Locked Out (HALO) and Low Amount to be Locked Out (LALO) relating to the  
department entry are programmed here. Entry of an amount larger than HALO or smaller than LALO can be  
prohibited.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
3 DP/PLU” for Department/PLU table programming is selected.  
1 DP” is selected.  
Main Menu  
Depress [] twice then [Enter].  
or  
Depress [3].  
Depress [1] or [Enter] key.  
Depress [] twice then [Enter].  
3 DIGIT LIMIT(PRICE)” is selected.  
Max. 7 digits (0 to 9999999)  
or  
Depress [3].  
Input a HALO value.  
[Enter]  
Max. 7 digits (0 to 9999999)  
Input a LALO value.  
[Enter]  
HALO and LALO are entered and printed.  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTES:  
1. HALO and LALO relating to the department entry are programmed as shown below. (Max. 7 digits)  
Input a HALO value or LALO value relating to the department entry, then depress the [Enter] key.  
XXXXXXX [Enter]  
(HALO or LALO)  
Amount limit at the department entry: HALO > Department preset price LALO  
Example of HALO programming  
To prohibit an entry of an amount larger than 4000, input 4000.  
(i.e. The amount equal to or smaller than 3999 can be entered.)  
Example of LALO programming  
To allow an entry of an amount equal to or larger than 40, input 40.  
6-106  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.21 Department Listing Capacity (LC) Programming  
The HALO and LALO programmed here are effective at the department entry in REG mode only. They  
are not effective in MGR and - mode, as a maximum of 7-digit amount value can be entered.  
Zeros must be entered as all the digits other than the highest digit. If any other value is entered, it will be  
regarded as a zero.  
Example) Entering 4001 to 4999 will all result in setting 4000.  
2. Regarding a department of which amount limit is individually preprogrammed, the HALO and LALO  
programmed here will be ignored.  
3. The HALO and LALO programmed here are cancelled at the department entry by depressing the [LC  
OPEN] or [OPEN] key. (i.e. Amounts of 2-digit more than HALO and of 1-digit less than LALO can be  
entered, up to a maximum of 7 digits.)  
A maximum of 7-digit amount value can be entered in MGR and - mode.  
3) Example  
To program 100000 for HALO and 10 for LALO.  
Operation  
LCD Display  
Remarks  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
The cursor is moved on to “3 DP/PLU”.  
3 DP/PLU” is selected.  
Depress the [3] or [Enter] key.  
Depress the [1] or [Enter] key.  
Depress the [] key twice.  
1 DP” is selected.  
The cursor is moved on to “3 DIGIT LIMIT  
(PRICE)”.  
Depress the [3] or [Enter] key.  
3 DIGIT LIMIT (PRICE)” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Input 100000, then depress the [Enter]  
key.  
(HALO: 100000)  
(continued on the next page)  
6-107  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.21 Department Listing Capacity (LC) Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
When the [Enter] key is depressed, the  
programmed data is printed.  
Input 10, then depress the [Enter] key.  
(LALO: 10)  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
AMOUNT LIMIT  
#01  
#02  
1000,00  
0,10  
0018 13:41TM  
6-108  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.22 Key Sticker Printing  
6.22 Key Sticker Printing  
Key stickers of department names which were programmed in the DEPARTMENT NAME PROGRAMMING can  
be printed on the receipt printer.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
For printing all department names  
ECR is being outside a sale and in SET mode.  
3 DP/PLU” for Department/PLU table programming is selected.  
1 DP” is selected.  
Main Menu  
Depress [] twice then [Enter].  
or Depress [3].  
Depress [1] or [Enter] key.  
Depress [] three times then [Enter].  
4 KEY STICKER PRINT” is selected.  
or Depress [4].  
The names of departments 1 to 15 are printed.  
Depress [1] or [Enter] key.  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
For printing part of department names  
ECR is being outside a sale and in SET mode.  
3 DP/PLU” for Department/PLU table programming is selected.  
1 DP” is selected.  
Main Menu  
Depress [] twice then [Enter].  
or Depress [3].  
Depress [1] or [Enter] key.  
Depress [] three times then [Enter].  
4 KEY STICKER PRINT” is selected.  
or Depress [4].  
Depress [] then [Enter].  
2 INDIVIDUAL DP” is selected.  
or Depress [2].  
Select desired departments with [] or  
[] key, then depress [Enter] key.  
The names of departments selected are printed.  
This operation is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
6-109  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.22 Key Sticker Printing  
NOTES:  
1. Print format  
< Single key >  
For the single key, a maximum of 12-digit department name (6 characters x 2 lines) can be printed.  
For a 7-digit-or-more department name, the first 6 digits are printed in the first line and the 7th digit and  
after are printed in the second line.  
The 6-digit-or-less department name is printed in the second line.  
For a 13-digit-or-more department name, the first 12 digits are printed.  
< Double-width key >  
For the double-width key, a maximum of 16-digit department name can be printed.  
The department name is printed in the second line.  
2. Departments 1 through 5 are fixed to the double-width keys and Departments 6 through 15 are fixed to the  
single keys. The number of the department is fixed to 15, as it remains unchanged even when the number  
of the department keys are changed in the SFKC PROGRAMMING.  
3. Key sticker printing should not be performed when the flat type keyboard is provided. (i.e. none of key caps  
are provided.)  
4. The key sticker is printed on the receipt only. Only the header is printed on the journal.  
5. When a department name contains two-byte characters, it will be printed with all one-byte characters.  
3) Example  
(1) To print all department names.  
Operation  
LCD Display  
Remarks  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
The cursor is moved on to “3 DP/PLU”.  
3 DP/PLU” is selected.  
Depress the [3] or [Enter] key.  
Depress the [1] or [Enter] key.  
Depress the [] key three times.  
Depress the [4] or [Enter] key.  
1 DP” is selected.  
The cursor is moved on to “4 KEY STICKER  
PRINT”.  
4 KEY STICKER PRINT” is selected.  
(continued on the next page)  
6-110  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.22 Key Sticker Printing  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
1 ALL DP” is selected.  
Depress the [1] or [Enter] key.  
A confirmation message is displayed.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this operation.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
0019 13:43TM  
6-111  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.22 Key Sticker Printing  
(2) To print part of department names.  
Operation  
LCD Display  
Remarks  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
The cursor is moved on to “3 DP/PLU”.  
3 DP/PLU” is selected.  
Depress the [3] or [Enter] key.  
Depress the [1] or [Enter] key.  
Depress the [] key three times.  
Depress the [4] or [Enter] key.  
Depress the [] key.  
1 DP” is selected.  
The cursor is moved on to “4 KEY STICKER  
PRINT”.  
4 KEY STICKER PRINT” is selected.  
The cursor is moved on to “2 INDIVIDUAL  
DP”.  
2 INDIVIDUAL DP” is selected  
Depress the [2] or [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
The department name already  
programmed is displayed.  
Move the cursor on to a desired  
department name of which key sticker  
is to be printed with the [] or [] key,  
then depress the [Enter] key.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this operation.  
6-112  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.23 PLU Table Programming  
6.23 PLU Table Programming  
This programming can be operated when new PLU items are to be added, PLU program data is to be changed,  
or PLUs are to be deleted.  
6.23.1 Programming or Changing  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] twice then [Enter].  
3 DP/PLU” for Department/PLU table programming is selected.  
or  
Depress [3].  
Depress [] then [Enter].  
2 PLU” is selected.  
or  
Depress [2].  
1 PLU SETTING” is selected.  
Depress [1] or [Enter] key.  
Input a PLU Code.  
[PLU]  
Max. 4 digits: 1 to 9999  
The ECR enters detailed setting mode for PLU.  
Input a linked department code (01 to 40),  
Link Department No. Setting (See *1.)  
Preset Price Setting (See *2.)  
then depress [Enter].  
Input a preset price (max. 6 digits: 1 to  
999999), then depress [Enter].  
(result: 0,01 to 9999,99)  
Input a 2nd preset price (max. 6 digits: 1 to  
999999), then depress [Enter].  
(result: 0,01 to 9999,99)  
2nd Preset Price Setting (See *3.)  
Input a 3rd preset price (max. 6 digits: 1 to  
999999), then depress [Enter].  
(result: 0,01 to 9999,99)  
3rd Preset Price Setting (See *4.)  
Input a VAT/Add-on tax status code (max. 8  
VAT/Add-on Tax Status Setting (See *5.)  
digits), then depress [Enter].  
The next PLU code (i.e. the currently programmed PLU code plus  
1) is displayed.  
[PLU]  
[End]  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
6-113  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.23 PLU Table Programming  
NOTES:  
1. A maximum of 1,000 PLUs are programmable.  
2
If a PLU is linked to a negative department, the PLU is automatically set as negative PLU.  
3. The [PLU] key here indicates the key labelled simply as “PLU” but not any PLU preset-code keys.  
*1: Linked Department Code  
Enter a 2-digit code of the department to which the PLU is linked.  
When the PLU is newly programmed, this entry is compulsory (an error will result if this entry is skipped.)  
[Enter]  
01 to 40  
*2: Preset Price  
For a preset PLU (preset-price PLU), enter a maximum of 6-digit price, and depress the [Enter] key.  
1 to 999999 (result: 0,01 to 9999,99)  
A zero-price (0,00) may be preset by entering 0 in the above operation.  
When no numeric value is entered and the [Enter] key is simply depressed, the PLU will be an open PLU  
(open-price PLU).  
*3: 2nd Preset Price  
For a preset PLU (preset-price PLU), enter a maximum of 6-digit price, and depress the [Enter] key.  
1 to 999999 (result: 0,01 to 9999,99)  
A zero-price (0,00) may be preset by entering 0 in the above operation.  
If the 2nd preset price entry is skipped, the 1st preset price will be automatically programmed as the 2nd  
preset price.  
*4: 3rd Preset Price  
For a preset PLU (preset-price PLU), enter a maximum of 6-digit price, and depress the [Enter] key.  
1 to 999999 (result: 0,01 to 9999,99)  
A zero-price (0,00) may be preset by entering 0 in the above operation.  
If the 3rd preset price entry is skipped, the 1st preset price will be automatically programmed as the 3rd  
preset price.  
*5: VAT or Add-on Tax Status  
Tax type should be selected from either “VAT” or “ADD-ON TAX” by the system option.  
Enter one- to eight-digit status codes for applicable VAT or Add-on Tax.  
[Enter]  
VAT or Add-on Tax Status Type  
0: Non-VAT or Non-taxable  
1: VAT 1 or Tax 1  
2: VAT 2 or Tax 2  
3: VAT 3 or Tax 3  
(More than one code can be entered for  
combining Tax 1 to Tax 8 taxable statuses.  
4: VAT 4 or Tax 4  
5: VAT 5 or Tax 5  
6: VAT 6 or Tax 6  
7: VAT 7 or Tax 7  
8: VAT 8 or Tax 8  
For example, enter 12 to select VAT 1 and VAT  
2 (or Tax 1 and Tax 2) taxable statuses.)  
A combination of VAT and Add-on tax statuses is not possible.  
6-114  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.23 PLU Table Programming  
3) Example  
To program the following PLU data:  
PLU Code:  
0010  
Linked Department:  
Preset Price:  
Department 1  
€1,00  
2nd Preset Price:  
3rd Preset Price:  
Tax Status:  
€1,20  
€1,50  
12 (VAT 1 and VAT 2)  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “3 DP/PLU”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
3 DP/PLU” is selected.  
Depress the [3] or [Enter] key.  
Depress the [] key.  
The cursor is moved on to “2 PLU”.  
2 PLU” is selected.  
Depress the [2] or [Enter] key.  
Depress the [1] or [Enter] key.  
1 PLU SETTING” is selected.  
PLU Code: Max. 4 digits (1 to 9999)  
Input 0010 (or 10), then depress the  
[PLU] key.  
(PLU Code 0010 is set.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 01 (or 1), then depress the  
[Enter] key.  
(Linked Department 1 is set.)  
(continued on the next page)  
6-115  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.23 PLU Table Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 100, then depress the [Enter]  
key.  
(Preset Price €1,00 is set.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 120, then depress the [Enter]  
key.  
(2nd Preset Price €1,20 is set.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 150, then depress the [Enter]  
key.  
(3rd Preset Price €1,50 is set.)  
The [?] key depression results in that the  
following guidance message appears on the  
LCD display.  
Input 12, then depress the [Enter] key.  
(VAT statuses 1 and 2 are set.)  
The [PLU] key depression completes  
the programming for PLU code 0010.  
When the [PLU] key is depressed, the next  
PLU code (i.e. the currently programmed  
PLU code plus 1) is displayed here.  
(Addition of new PLUs and changes of  
current PLUs can be performed.)  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
31-10-2005 MON #0  
PLU  
0010 PLU0010  
#01  
#02  
#03  
#04  
#05  
01  
1,00@  
1,20@  
1,50@  
12  
0001  
0020 13:45TM  
6-116  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.23 PLU Table Programming  
6.23.2 Deletion  
To delete a PLU with sales data of zero:  
To delete a PLU with sales data of not zero: After PLU Reset  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
Individual PLU Deletion:  
The programmed PLU data is deleted individually.  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] twice then [Enter].  
3 DP/PLU” for Department/PLU table programming is selected.  
or  
Depress [3].  
Depress [] then [Enter].  
2 PLU” is selected.  
or  
Depress [2].  
Depress [] three times then [Enter].  
4 DELETE (INDIV)” is selected.  
or  
Depress [4].  
Max. 4 digits: 1 to 9999  
Input a PLU code to be deleted.  
The specified PLU is deleted.  
[PLU]  
This operation is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
3) Example  
To delete PLU Code 0501 (Tuna Can) that was once programmed.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “3 DP/PLU”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
Depress the [3] or [Enter] key.  
(continued on the next page)  
6-117  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.23 PLU Table Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
Depress the [] key.  
2 PLU” is selected.  
Depress the [1] or [Enter] key.  
Depress the [] key three times.  
Depress the [4] or [Enter] key.  
The cursor is moved on to “4 DELETE  
(INDIV)”.  
4 DELETE (INDIV)” is selected.  
PLU Code: Max. 4 digits (1 to 9999)  
Input 0501 (or 501), then depress the  
[PLU] key.  
(PLU Code 0501 is specified.)  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this operation.  
6-118  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.23 PLU Table Programming  
All PLU Deletion:  
The programmed PLU data is deleted entirely.  
1) Menu Tree  
2) Operation  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “3 DP/PLU”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
Depress the [3] or [Enter] key.  
Depress the [] key.  
2 PLU” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key four times.  
Depress the [5] or [Enter] key.  
Depress the [ALL VOID] key.  
The cursor is moved on to “5 DELETE  
(ALL)”.  
5 DELETE (ALL)” is selected.  
The entire programmed PLU data is deleted,  
then the following message is displayed.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this operation.  
6-119  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.24 PLU Preset Price Setting or Changing  
6.24 PLU Preset Price Setting or Changing  
The preset price of each PLU may be set in the PLU TABLE PROGRAMMING already described. However, in  
setting or changing the price only (not other programmed data), the following operation will be more convenient.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] twice then [Enter].  
3 DP/PLU” for Department/PLU table programming is selected.  
or  
Depress [3].  
Depress [] then [Enter].  
2 PLU” is selected.  
or  
Depress [2].  
Depress [] then [Enter].  
2 UNIT PRICE” is selected.  
or  
Depress [2].  
Input a PLU code of which PLU preset  
price is to be set or changed.  
PLU code: Max. 4 digits (1 to 9999)  
[PLU]  
Max. 6 digits (0 to 999999) (NOTE1)  
Input 1st preset price, then [Enter].  
Input 2nd preset price, then [Enter].  
Input 3rd preset price, then [Enter].  
[PLU]  
Max. 6 digits (0 to 999999) (NOTE1)  
Max. 6 digits (0 to 999999) (NOTE1)  
The preset prices are entered and printed. (NOTE3)  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
6-120  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.24 PLU Preset Price Setting or Changing  
NOTES:  
1. When no price is input then the [Enter] key is depressed, the PLU will be open (i.e. open-price PLU).  
2. If inputting a nonexistent PLU code that was not programmed in the PLU Table Programming, this may  
cause an error.  
3. The [PLU] key depression here results in that the next PLU code (i.e. the currently programmed PLU code  
plus 1) is displayed. If it does not exist, the guidance message requiring a PLU code input is displayed.  
3) Example  
To change the preset prices of PLU Code 0001 as shown below:  
PLU Code:  
0001  
1st Preset Price: It is changed from €1,05 to €3,15.  
2nd Preset Price: It is changed from €2,10 to €5,40.  
3rd Preset Price: It remains €3,20.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “3 DP/PLU”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
Depress the [3] or [Enter] key.  
Depress the [] key.  
The cursor is moved on to “2 PLU”.  
The cursor is moved on to “2 UNIT PRICE”.  
PLU Code 0001 is specified.  
Depress the [2] or [Enter] key.  
Depress the [] key.  
Depress the [2] or [Enter] key.  
Input 1, then depress the [PLU] key.  
(continued on the next page)  
6-121  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.24 PLU Preset Price Setting or Changing  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The 1st preset price is changed from €1,05  
to €3,15.  
Make sure the cursor is shown on  
01PRICE. Then, input 315 and  
depress the [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
The 2nd preset price is changed from €2,10  
to €5,40.  
Make sure the cursor is shown on  
022ND PRICE. Then, input 540 and  
depress the [Enter] key.  
PLU0001 preset price setting is ended.  
As the 3rd preset price remains  
unchanged, depress the [PLU] key.  
When the [Enter] key is depressed, the  
programmed data is printed.  
The next PLU code (i.e. the currently  
programmed PLU code plus 1) is displayed.  
After the [PLU] key depression  
If the next PLU code (i.e. the currently  
programmed PLU code plus 1) does not  
exist, this guidance message requiring a PLU  
code input is displayed.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
PLU PRICE  
0001 PLU0001  
#01  
#02  
#03  
3,15@  
5,40@  
3,20@  
0021 13:47TM  
6-122  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.25 PLU Preset-Code Key Setting  
6.25 PLU Preset-Code Key Setting  
When there are any keys programmed as PLU Preset-code Keys (SFKC 96) on the ECR Keyboard (ordinary or  
Flat type), and /or when the PK-2 PLU Keyboard (hardware option) is connected to the ECR, a PLU code may be  
preset to each of those keys in this operation.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
For PLU Preset-Code Key (SFKC 96)  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] twice then [Enter].  
3 DP/PLU” is selected.  
or  
Depress [3].  
Depress [] then [Enter].  
2 PLU” is selected.  
or  
Depress [2]  
Depress [] twice then [Enter].  
3 ASSIGN TO KEYBOARD” is selected.  
or  
Depress [3].  
Depress [] then [Enter].  
2 PLU CODE KEY” is selected.  
or  
Depress [2]  
A 4-digit PLU code to be assigned to a key is specified.  
Input a PLU Code.  
[Enter]  
See Key Location Code on the next page.  
Input a desired key location code.  
[Enter]  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
6-123  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.25 PLU Preset-Code Key Setting  
For PK-2 Keyboard  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] twice then [Enter].  
3 DP/PLU” is selected.  
or  
Depress [3].  
Depress [] then [Enter].  
2 PLU” is selected.  
or  
Depress [2]  
Depress [] twice then [Enter].  
3 ASSIGN TO KEYBOARD” is selected.  
or  
Depress [3].  
Depress [Enter].  
or  
1 PK-2” is selected.  
Depress [1]  
A 4-digit PLU code to be assigned to a key is specified.  
Input a PLU Code.  
[Enter]  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE: PLU Codes 1 through 130 are automatically assigned to the PK-2 after performing a RAM Clear.  
Key Location Code  
Ordinary type keyboard  
1
2
3
4
5
6
7
8
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
9
10  
11  
12  
* For the double-width key, the key location code on the right is effective.  
6-124  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.25 PLU Preset-Code Key Setting  
Flat type keyboard  
1
2
3
4
5
6
7
8
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
77  
78  
83  
84  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
100  
101  
102  
9
10  
11  
12  
13  
14  
73  
74  
75  
85  
103  
79  
80  
81  
82  
86  
87  
88  
89  
104  
105  
106  
76  
3) Example  
(1) To assign PLU Code 1111 to Key Location Code 55 on the ordinary type keyboard.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “3 DP/PLU”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
3 DP/PLU” is selected.  
Depress the [3] or [Enter] key.  
Depress the [] key.  
The cursor is moved on to “2 PLU”.  
2 PLU” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key twice.  
Depress the [3] or [Enter] key.  
The cursor is moved on to “3 ASSIGN TO  
KEYBOARD”.  
3 ASSIGN TO KEYBOARD” is selected.  
(continued on the next page)  
6-125  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.25 PLU Preset-Code Key Setting  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 PLU CODE  
KEY”.  
Depress the [] key.  
2 PLU CODE KEY” is selected.  
Depress the [2] or [Enter] key.  
On this screen, when inputting a PLU code  
then depressing a PLU preset-code key, the  
[PLU] key setting is possible. In this case,  
the PLU preset-code keys on the standard  
flat type keyboard can be set. The other  
keys should be set with the key location  
code.  
Input 55, then depress the [Enter] key.  
(Key Location Code 55 is set.)  
Input 1111, then depress the [Enter]  
key.  
(PLU Code 1111 is set.)  
The display returns to the key location  
code input screen.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
(2) To assign PLU Code 1111 on the PK-2 keyboard.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “3 DP/PLU”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
twice.  
3 DP/PLU” is selected.  
Depress the [3] or [Enter] key.  
(continued on the next page)  
6-126  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.25 PLU Preset-Code Key Setting  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “2 PLU”.  
Depress the [] key.  
2 PLU” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key twice.  
The cursor is moved on to “3 ASSIGN TO  
KEYBOARD”.  
3 ASSIGN TO KEYBOARD” is selected.  
Depress the [3] or [Enter] key.  
Depress the [1] or [Enter] key.  
1 PK-2” is selected.  
Input 1111, then depress the [Enter]  
key.  
(PLU Code 1111 is set.)  
Directly depress a key on the PK-2  
keyboard where PLU Code 1111 is to  
be assigned.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
6-127  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.26 %+ and %- Preset Rate Setting  
6.26 %+ and %- Preset Rate Setting  
A preset rate may be set on each of the [%+] and [%-] keys, one independent rate for each key. Once a rate is  
preset, the % key will simply be depressed without a prior rate entry to activate the preset rate. If a rate is  
entered prior to the depression of the key, the entered rate (manual rate) will be activated instead.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] three times then [Enter].  
4 RATE, LIMIT AMOUNT” is selected.  
or  
Depress [4].  
1 %- RATE (%-/%+)” is selected.  
Depress the [1] or [Enter] key.  
Select a [%] key to be programmed  
To select [%-] key, depress [1] or [Enter].  
To select [%+] key, depress [2] or depress [] then [Enter].  
with the [] key.  
[Enter]  
0,001 to 99,999 (%): Use the [.] key if decimal portion is contained.  
(See NOTE below.)  
Input a Preset Rate.  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE: When inputting 0, the % preset rate will be cancelled. If doing so, the % preset rate should be set in the  
registration operation.  
6-128  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.26 %+ and %- Preset Rate Setting  
3) Example  
To program the following rate on the [%-] key:  
[%-] key ………. Rate 5,00%  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “4 RATE, LIMIT  
AMOUNT”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
three times.  
4 RATE, LIMIT AMOUNT” is selected.  
1 %- RATE (%-/%+)” is selected.  
1 %-” is selected.  
Depress the [4] or [Enter] key.  
Depress the [1] or [Enter] key.  
Depress the [1] or [Enter] key.  
Input 5.  
Preset Rate 5,00% is entered.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
% RATE  
5%  
%-  
0022 13:49TM  
6-129  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.27 VAT or Add-on Tax Rate Setting  
6.27 VAT or Add-on Tax Rate Setting  
The rates of VATs or Add-on Taxes are set in this operation,. (Which VAT or Add-on Tax is applicable to each  
Department or PLU has already been set in the DEPARTMENT TABLE PROGRAMMING and PLU TABLE  
PROGRAMMING.)  
After Financial Daily Reset  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] three times then [Enter].  
4 RATE, LIMIT AMOUNT” is selected.  
or  
Depress [4].  
Depress the [] then [Enter]  
2 VAT/TAX RATE” is selected.  
or  
Depress [2].  
Input a rate of VAT1 or TAX1, then  
0,01 to 99,99 (%): Use the [.] key if decimal portion is contained.  
0,01 to 99,99 (%): Use the [.] key if decimal portion is contained.  
0,01 to 99,99 (%): Use the [.] key if decimal portion is contained.  
0,01 to 99,99 (%): Use the [.] key if decimal portion is contained.  
0,01 to 99,99 (%): Use the [.] key if decimal portion is contained.  
0,01 to 99,99 (%): Use the [.] key if decimal portion is contained.  
0,01 to 99,99 (%): Use the [.] key if decimal portion is contained.  
0,01 to 99,99 (%): Use the [.] key if decimal portion is contained.  
depress the [Enter] key.  
Input a rate of VAT2 or TAX2, then  
depress the [Enter] key.  
Input a rate of VAT3 or TAX3, then  
depress the [Enter] key.  
Input a rate of VAT4 or TAX4, then  
depress the [Enter] key.  
Input a rate of VAT5 or TAX5, then  
depress the [Enter] key.  
Input a rate of VAT6 or TAX6, then  
depress the [Enter] key.  
Input a rate of VAT7 or TAX7, then  
depress the [Enter] key.  
Input a rate of VAT8 or TAX8, then  
depress the [Enter] key.  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE: Either VAT or Add-on Tax can be used. Tax feature is according to the status selected in Address No.  
21, Bit No. 5 of the system option.  
6-130  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.27 VAT or Add-on Tax Rate Setting  
3) Example  
To set the following VAT rate:  
VAT1………10%  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “4 RATE, LIMIT  
AMOUNT”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
three times.  
4 RATE, LIMIT AMOUNT” is selected.  
Depress the [4] or [Enter] key.  
Depress the [] key  
The cursor is moved on to “2 VAT/TAX  
RATE”.  
2 VAT/TAX RATE” is selected.  
Depress the [2] or [Enter] key.  
Input 10, then depress the [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Depress the [] six times.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
VAT/TAX RATE  
VAT1  
10%  
0023 13:51TM  
6-131  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.28 Foreign Currency Exchange Rate Setting  
6.28 Foreign Currency Exchange Rate Setting  
The rate of each foreign currency (corresponding to the [CUR1] to [CUR5] keys) are set in this operation.  
By setting a rate on each Foreign Currency Key, reading the sale total and tendering in the foreign currency value  
will be possible for sale finalization.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode  
Main Menu  
Depress [] three times then [Enter].  
4 RATE, LIMIT AMOUNT” is selected.  
or  
Depress [4].  
Depress [] twice then [Enter].  
3 CUR EXCHANGE RATE” is selected.  
or  
Depress [3].  
Input the rate of [CUR1] key, then  
0,000001 to 9999,999999 (%): Use the [.] key if decimal portion is  
contained. (See NOTE below.)  
depress [Enter].  
Input the rate of [CUR2] key, then  
0,000001 to 9999,999999 (%): Use the [.] key if decimal portion is  
contained. (See NOTE below.)  
depress [Enter].  
Input the rate of [CUR3] key, then  
0,000001 to 9999,999999 (%): Use the [.] key if decimal portion is  
contained. (See NOTE below.)  
depress [Enter].  
Input the rate of [CUR4] key, then  
0,000001 to 9999,999999 (%): Use the [.] key if decimal portion is  
contained. (See NOTE below.)  
depress [Enter].  
Input the rate of [CUR5] key, then  
0,000001 to 9999,999999 (%): Use the [.] key if decimal portion is  
contained. (See NOTE below.)  
depress [Enter].  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE: When inputting 0, the rate of the foreign currency will be cancelled. If doing so, the rate of the foreign  
currency should be set in the registration operation.  
6-132  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.28 Foreign Currency Exchange Rate Setting  
Foreign Currency Exchange Rate Calculation  
1. The rate must be calculated in the subsidiary currency unit values for both the domestic and the foreign  
currencies. (In case of calculating the rate from the domestic to a foreign currency with the same zero-  
suppress form, such as from Euro to U.S. $, it will be no problem even if it is calculated in the main currency  
of Euro and $. However, in case of exchanging from a domestic currency such as Euro or $ to Japanese  
yen, or vice versa, this rule must be obeyed; otherwise a wrong rate will result.)  
2. Calculate the required foreign currency value equivalent to the domestic currency value “1”. Then the  
obtained value is the Exchange Rate value to be entered in the setting operation stated on the previous  
page.  
3) Example  
To set two foreign currency rates:  
(The rates here are merely examples, and may be different from the actual rates currently in effect.)  
Conditions given for Domestic Currency and Foreign Currencies  
(DOMESTIC)  
EURO  
(CUR1)  
U.S. Dollar  
(CUR2)  
Japanese Yen  
€1,00  
$1,20  
¥137,74  
1 EURO Cent  
1.20 Cent  
1,3774 yen  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “4 RATE, LIMIT  
AMOUNT”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
three times.  
4 RATE, LIMIT AMOUNT” is selected.  
Depress the [4] or [Enter] key.  
Depress the [] key twice.  
The cursor is moved on to “3 CUR  
EXCHANGE RATE”.  
3 CUR EXCHANGE RATE” is selected.  
Depress the [3] or [Enter] key.  
(continued on the next page)  
6-133  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.28 Foreign Currency Exchange Rate Setting  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The exchange rate from € to $ is set on the  
[CUR1] key.  
Make sure the cursor is shown on  
01CUR1. Then, input 1.20 and  
depress the [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
The exchange rate from € to Japan Yen is  
set on the [CUR2] key.  
Make sure the cursor is shown on  
02CUR2. Then, input 1.3774 and  
depress the [Enter] key.  
The cursor is moved on to “05CUR5”.  
Depress the [] key twice.  
Make sure the cursor is shown on  
05CUR5.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
CUR RATE  
CUR1  
CUR2  
1.2  
1,3774∗  
0024 13:53TM  
Resetting a Foreign Currency Rate Once Set  
Input 0 in place of the Exchange Rate for the Foreign Currency in the setting operation. Then the rate for that  
foreign currency will be reset. The rate of the Foreign Currency Key thus reset cannot be used in sales entries.  
6-134  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.29 Negative Amount Key Limit Amount Setting  
6.29 Negative Amount Key Limit Amount Setting  
The limit amount to be entered through each of the negative-amount keys [VND CPN], [STR CPN], and [-] Are  
set here.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] three times then [Enter].  
4 RATE, LIMIT AMOUNT” is selected.  
or  
Depress [4].  
Depress [] three times then [Enter].  
4 DISC AMT LIMIT” is selected.  
0 to 999999 (€0,00 to €9999,99)  
0 to 999999 (€0,00 to €9999,99)  
0 to 999999 (€0,00 to €9999,99)  
or  
Depress [4].  
Input the limit amount of the Vender  
Coupon Key ([VND CPN]), then  
depress [Enter].  
Input the limit amount of the Store  
Coupon Key ([STR CPN]), then  
depress [Enter].  
Input the limit amount of the Amount  
Discount Key ([-]), then depress  
[Enter].  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTES: 1. The [VND CPN] key will not be restricted by the limit amount set here but the amount up to 7  
digits will be entered in MGR or - mode.  
2. The limit amount set here cannot be released by the [LC OPEN] (or [OPEN]) key in transaction  
entries.  
6-135  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.29 Negative Amount Key Limit Amount Setting  
3) Example  
To set the following preset amount on the keys below:  
Key  
[VND CPN]  
[STR CPN]  
Limit Amount  
10.00  
20.00  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “4 RATE, LIMIT  
AMOUNT”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
three times.  
4 RATE, LIMIT AMOUNT” is selected.  
Depress the [4] or [Enter] key.  
Depress the [] key three times.  
Depress the [4] or [Enter] key.  
The cursor is moved on to “4 DISC AMT  
LIMIT”.  
4 DISC AMT LIMIT” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Input 1000, then depress the [Enter]  
key.  
(The limit amount of the [VND CPN]  
key is set.)  
Input 2000, then depress the [Enter]  
key.  
(The limit amount of the [STR CPN]  
key is set.)  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
31-10-2005 MON #0  
LIMIT TABLE  
V.CPN  
S.CPN  
10,00  
20,00  
0025 13:55TM  
6-136  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.30 Time Setting or Adjustment  
6.30 Time Setting or Adjustment  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] four times then [Enter].  
5 BASIC” is selected.  
or  
Depress [5].  
1 TIME” is selected.  
Depress [1] or [Enter].  
4-digiti-time value (HHMM) (See NOTE below.)  
Input a 4-digit time value.  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE: If an hour value of more than 23 or a minute value of more than 59 is entered, the current data remains  
unchanged by setting or adjusting the time.  
3) Example  
To set time “1:15 p.m. (13:15)”  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “5 BASIC”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
four times.  
5 BASIC” is selected.  
Depress the [5] or [Enter] key.  
1 TIME” is selected.  
Depress the [1] or [Enter] key.  
(continued on the next page)  
6-137  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.31 Date Setting or Adjustment  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The time “13:15” is set.  
Input 1315.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
31-10-2005 MON #0  
TIME  
13:15TM  
0026 13:15TM  
6.31 Date Setting or Adjustment  
Any time outside a sale  
CONDITION  
Mode Lock: SET  
OPERATION  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] four times then [Enter].  
5 BASIC” is selected.  
or  
Depress [5].  
Depress [] then [Enter].  
2 DATE” is selected.  
or  
Depress [2].  
9-digit value (Day-of-Week Code & DDMMYYYY)  
Input a 9-digit value.  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE: The date entry order may be Month-Day-Year or Year-Month-Day instead of Day-Month-Year if so  
selected in the system option. The “Day-Month-Year” is set as default.  
6-138  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.31 Date Setting or Adjustment  
3) Example  
To set Date “Monday 31 October, 2005”  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “5 BASIC”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
four times.  
5 BASIC” is selected.  
Depress the [5] or [Enter] key.  
Depress the [] key.  
The cursor is moved on to “2 DATE”.  
2 DATE” is selected.  
Depress the [2] or [Enter] key.  
Depress the [] key.  
Input 131102005.  
1 31 10 2005  
31 October, 2005  
Day-of Week Code: 1=Monday  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
31-10-2005 MON #0  
DATE  
1 31-10-2005  
0027 13:15TM  
6-139  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.32 Store/Register No. Setting  
6.32 Store/Register No. Setting  
A maximum of 6 digits may be set as ID No. for the store and/or register. And once set, it will be printed on every  
receipt.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] four times then [Enter].  
5 BASIC” is selected.  
or  
Depress [5].  
Depress [] twice then [Enter].  
3 REGISTER NO.” is selected.  
or  
Depress [3].  
6-digit value (0 to 999999)  
Input a 6-digit value.  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE:  
The preceding zeros, if entered, will not be printed. For example, if “001234” is entered in the above  
operation, “#1234” will always be printed as the Register No.  
3) Example  
To set the Register No. of this ECR 3001  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “5 BASIC”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
four times.  
5 BASIC” is selected.  
Depress the [5] or [Enter] key.  
(continued on the next page)  
6-140  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.32 Store/Register No. Setting  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “3 REGISTER  
NO.”.  
Depress the [] key twice.  
3 REGISTER NO.” is selected.  
Depress the [3] or [Enter] key.  
Input 3001.  
(Store/Register No. 3001 is set.)  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #0  
REG No.  
#3001  
0028 13:17TM  
6-141  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.33 Hourly Range Table Setting  
6.33 Hourly Range Table Setting  
By setting a maximum of 24 terms per day, sales data control for each term can be performed.  
CONDITION  
OPERATION  
After Hourly Range Reset  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] four times then [Enter].  
5 BASIC” is selected.  
or  
Depress [5].  
Depress [] three times then [Enter].  
4 HOURLY RANGE” is selected.  
or  
Depress [4].  
1 SETTING” is selected.  
Depress [1] or [Enter].  
Input a numeric value for TIME01, then  
A 4-digit numeric value is input with the 24 hour time system  
(HHMM)  
depress [Enter].  
Input a numeric value for TIME24, then  
A 4-digit numeric value is input with the 24 hour time system  
(HHMM)  
depress [Enter].  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTES:  
1. A maximum of 24 terms can be set per day.  
2. To partially or entirely change the hourly range table once set, do the entire setting operation over again.  
3. Do not set a term across 24:00, such as “23:00 to 1:00”.  
4. After performing a RAM Clear, the hourly range table is set with hourly terms in the range of 7:00 to 23:00.  
6-142  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.33 Hourly Range Table Setting  
3) Example  
To set the following hourly range table:  
TIME01  
TIME02  
TIME03  
TIME04  
until 8:00*  
8:00 to 12:00  
12:00 to 15:00  
15:00 to 19:00  
*(The first term is automatically continued from 19:00 of the preceding day.)  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “5 BASIC”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
four times.  
5 BASIC” is selected.  
Depress the [5] or [Enter] key.  
Depress the [] key three times.  
Depress the [4] or [Enter] key.  
Depress the [1] or [Enter] key.  
The cursor is moved on to “4 HOURLY  
RANGE”.  
4 HOURLY RANGE” is selected.  
1 SETTING” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Input 0800, then depress the [Enter]  
key.  
(TIME01 is set with 8:00.)  
Input 1200, then depress the [Enter]  
key.  
(TIME02 is set with 12:00.)  
(continued on the next page)  
6-143  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.33 Hourly Range Table Setting  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
Input 1500, then depress the [Enter]  
key.  
(TIME03 is set with 15:00.)  
Input 1900, then depress the [Enter]  
key.  
(TIME04 is set with 19:00.)  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
• Hourly Range Table Resetting Procedure  
If the hourly range table is reset, follow the procedure below.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “5 BASIC”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
four times.  
5 BASIC” is selected.  
Depress the [5] or [Enter] key.  
Depress the [] key three times.  
Depress the [4] or [Enter] key.  
Depress the [] key.  
The cursor is moved on to “4 HOURLY  
RANGE”.  
4 HOURLY RANGE” is selected.  
The cursor is moved on to “2 RESET”.  
(continued on the next page)  
6-144  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.33 Hourly Range Table Setting  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
2 RESET” is selected.  
Depress the [2] or [Enter] key.  
A guidance message is displayed.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
-- Receipt Sample of Hourly Range Table Setting --  
-- Receipt Sample for Hourly Range Table Resetting --  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #3001  
31-10-2005 MON #3001  
HOURLY  
HOURLY  
08:00TM  
12:00TM  
15:00TM  
19:00TM  
0030 13:21TM  
0029 13:19TM  
6-145  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.34 Tone Volume Setting  
6.34 Tone Volume Setting  
Key-in tone for the ECR keyboard and error tone are selectable from High, Low, and OFF.  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] four times then [Enter].  
5 BASIC” is selected.  
or  
Depress [5].  
Depress [] four times then [Enter].  
5 KEY-IN TONE” is selected.  
or  
Depress [5].  
Select a key tone with the [] or []  
It is selectable from HIGH, LOW, and OFF.  
key.  
The [Enter] key depression results in that the selected key tone  
sounds for 2 seconds. (See NOTE 1 below.)  
[Enter]  
[End]  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
NOTES:  
1. The [Enter] key depression results in that the selected key tone sounds for 2 seconds. When the key tone  
“OFF” is selected, no sound occurs.  
2. After performing a RAM Clear, the key tone “HIGH” is set as standard.  
6-146  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.34 Tone Volume Setting  
3) Example  
To change the key tone from “HIGH” (default setting) to “LOW”.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “5 BASIC”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
four times.  
5 BASIC” is selected.  
Depress the [5] or [Enter] key.  
Depress the [] key four times.  
Depress the [5] or [Enter] key.  
Depress the [] key.  
The cursor is moved on to “5 KEY-IN TONE”.  
5 KEY-IN TONE” is selected.  
The cursor is moved on to “1 TONE  
VOLUME (LOW)”.  
1 TONE VOLUME (LOW)” is selected.  
Depress the [1] or [Enter] key.  
The selected key tone sounds for 2  
seconds.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
31-10-2005 MON #3001  
KEY TONE  
TONE VOLUME (LOW)  
0031 13:23TM  
6-147  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.35 Report Item Print/Non-Print Setting  
6.35 Report Item Print/Non-Print Setting  
Items to be printed on Financial, Cashier, and Salesperson Reports are set here.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] five times then [Enter].  
6 OTHER” is selected.  
or  
Depress [6].  
1 REPORT PRINT ITEM” is selected.  
Depress [1] or [Enter] key.  
Move the cursor on to a report item  
name to be set with the [] or [] key.  
Select either Print or Non-print status  
for the report item name with the [] or  
[] key.  
[Enter]  
[End]  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
NOTES:  
1. Items which are set with Print status will be printed on the reports. They are not affected by the open/close  
status of the key.  
2. Financial report item names are programmed in Section 6.14 Financial Report Item Name Programming.  
3. All item names are set with Print status after performing a RAM Clear.  
4. When the open/close status of the key is changed in the SFKC Programming, perform this setting again to  
set the print/non-print status of the corresponding key.  
6-148  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.35 Report Item Print/Non-Print Setting  
3) Example  
To set Item Code 3 “NEG GT” with Non-print status.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “6 OTHER”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
five times.  
6 OTHER” is selected.  
Depress the [6] or [Enter] key.  
1 REPORT PRINT ITEM” is selected.  
Depress the [1] or [Enter] key.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Depress the [] key twice.  
(Item Code 3 (“NEG GT”) is selected.)  
The status reverses between Y and N with  
the [] or [] key.  
Select either Print or Non-print status  
with the [] or [] key.  
The [Enter] key depression results in  
that the setting data is entered.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #3001  
REPORT PRINT  
#003 NEG GT  
#003 NEG GT  
0
1
0032 13:25TM  
6-149  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.35 Report Item Print/Non-Print Setting  
Report Item Name Table  
Item  
Code  
Item Name  
Standard Program  
1
Ground Total  
G T  
2
NET GT  
N
N
E
E
T
G
G
T
T
3
NEG GT  
G
4
Gross Sale  
G S  
5
Tax 1 (Add-on Tax 1)  
T
T
T
T
T
T
T
T
T
A
A
A
A
A
A
A
A
A
X
X
X
X
X
X
X
X
X
1
2
3
4
5
6
7
8
6
Tax 2 (Add-on Tax 2)  
7
Tax 3 (Add-on Tax 3)  
8
Tax 4 (Add-on Tax 4)  
9
Tax 5 (Add-on Tax 5)  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
28  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
Tax 6 (Add-on Tax 6)  
Tax 7 (Add-on Tax 7)  
Tax 8 (Add-on Tax 8)  
Tax Total  
T
L
Net Sale with Tax  
N S  
% +  
%
V
D
-
% I (usually %+)  
% II (usually %-)  
-
.
Vendor Coupon  
C
S
P
.
P
C
N
Amount Discount  
I
Negative Depts. Total  
Special Round Fractions  
Net Sale (All-Media Sales)  
Cash Sales (AT/TL)  
D
P
T
L
S
R
N
D
N S  
C
C
C
M
C
C
C
C
C
C
R
P
C
C
C
C
C
C
C
C
C
C
C
C
A
H
R
I
S
E
T
S
N
T
T
T
T
T
A
H
C
Media 1 Sales (CHK)  
K
Media 2 Sales (CRT)  
Media 3 Sales (MISC)  
Media 4 Sales (CPN)  
C
P
R
R
R
R
R
/
Media 5 Sales (Credit 1)  
Media 6 Sales (Credit 2)  
Media 7 Sales (Credit 3)  
Media 8 Sales (Credit 4)  
Media 9 Sales (Credit 5)  
Received-on-Account  
Paid-Out  
T
T
T
T
T
L
L
L
L
L
1
2
3
4
5
O
A
A
A
A
A
A
H
K
K
K
K
K
Cash-in-drawer  
S
S
S
S
S
S
E
H
H
H
H
H
H
C
C
C
C
C
C
I
D
U
U
U
U
U
I
Cash-in-drawer (Foreign Currency 1)  
Cash-in-drawer (Foreign Currency 2)  
Cash-in-drawer (Foreign Currency 3)  
Cash-in-drawer (Foreign Currency 4)  
Cash-in-drawer (Foreign Currency 5)  
Media 1-in-drawer (CHK)  
Cheque-in-drawer (Foreign Currency 1)  
Cheque-in-drawer (Foreign Currency 2)  
Cheque-in-drawer (Foreign Currency 3)  
Cheque-in-drawer (Foreign Currency 4)  
Cheque-in-drawer (Foreign Currency 5)  
C
C
C
C
C
R
R
R
R
R
D
1
2
3
4
5
I
I
I
I
I
D
D
D
D
D
K
U
U
U
U
U
R
R
R
R
R
1
I
I
I
I
I
D
D
D
D
D
2
3
4
5
6-150  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.35 Report Item Print/Non-Print Setting  
Report Item Name Table (Continued)  
Item Name  
Item  
Standard Program  
Code  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
Media 2-in-drawer (CRT)  
C
C
C
C
C
C
M
M
M
M
M
M
C
C
C
C
C
C
C
C
C
C
C
C
C
C
M
C
C
C
C
C
C
C
V
R
R
R
R
R
R
I
T
T
T
T
T
T
S
S
S
S
S
S
N
N
N
N
N
N
T
T
T
T
T
S
I
D
U
U
U
U
U
I
Credit-in-drawer (Foreign Currency 1)  
Credit-in-drawer (Foreign Currency 2)  
Credit-in-drawer (Foreign Currency 3)  
Credit-in-drawer (Foreign Currency 4)  
Credit-in-drawer (Foreign Currency 5)  
Media 3-in-drawer (MISC)  
MISC-in-drawer (Foreign Currency 1)  
MISC-in-drawer (Foreign Currency 2)  
MISC-in-drawer (Foreign Currency 3)  
MISC-in-drawer (Foreign Currency 4)  
MISC-in-drawer (Foreign Currency 5)  
Media 4-in-drawer (CPN)  
C
C
C
C
C
R
R
R
R
R
D
U
U
U
U
U
1
2
3
4
5
I
I
I
I
I
D
D
D
D
D
C
C
C
C
C
C
I
C
C
C
C
C
D
U
U
U
U
U
D
D
D
D
D
D
F
R
R
R
R
R
1
2
3
4
5
I
I
I
I
I
D
D
D
D
D
I
I
I
I
P
P
P
P
P
P
R
R
R
R
R
A
K
R
I
I
C
C
C
C
C
I
Coupon-in-drawer (Foreign Currency 1)  
Coupon-in-drawer (Foreign Currency 2)  
Coupon-in-drawer (Foreign Currency 3)  
Coupon-in-drawer (Foreign Currency 4)  
Coupon-in-drawer (Foreign Currency 5)  
Media 5-in-drawer (Credit 1)  
Media 6-in-drawer (Credit 2)  
Media 7-in-drawer (Credit 3)  
Media 8-in-drawer (Credit 4)  
Media 9-in-drawer (Credit 5)  
Cash-in-drawer Difference  
Media 1-in-drawer Difference  
Media 2-in-drawer Difference  
Media 3-in-drawer Difference  
Media 4-in-drawer Difference  
Media 5-in-drawer Difference  
Media 6-in-drawer Difference  
Media 7-in-drawer Difference  
Media 8-in-drawer Difference  
Media 9-in-drawer Difference  
Item Correct  
R
R
R
R
R
1
2
3
4
5
I
1
2
3
4
5
I
I
I
I
I
D
D
D
D
D
I
I
I
I
H
D
F
F
I
T
S
N
T
T
T
T
T
R
I
D
I
F
I
C
D
I
P
R
R
R
R
R
O
O
I
D
F
I
1
2
D
D
D
D
D
F
F
F
F
F
I
3
I
4
I
5
I
R
D
C
Void  
Misc. Void  
M
A
S
L
V
D
D
All Void  
L
.
V
N
Store Coupon  
S
C
N
G
P
-
Returned Merchandise  
R
R
%
D
T
T
E
-
Negative Mode Total  
%- on Line Items  
Amount Discount on Line Items  
Transfer Balance GT  
I
S
F
F
F
C
R
R
R
T
L
Transfer + GT  
T
+
-
G
G
T
T
Transfer – GT  
T
6-151  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.35 Report Item Print/Non-Print Setting  
Report Item Name Table (Continued)  
Item Name  
Item  
Code  
Standard Program  
91  
Transfer + Daily  
T
T
P
P
P
T
V
T
V
T
V
T
V
T
V
T
V
T
V
T
V
V
R
R
B
B
B
X
A
X
A
X
A
X
A
X
A
X
A
X
A
X
A
A
F
F
+
-
92  
Transfer – Daily  
93  
PB (Previous Balance) Sales  
PB R/A (PB Paid)  
PB PO (PB Refunded)  
Taxable Total 1  
T
R
P
L
1
L
2
L
3
L
4
L
5
L
6
L
7
L
8
L
94  
/
A
95  
O
1
96  
B
T
B
T
B
T
B
T
B
T
B
T
B
T
B
T
T
97  
VAT 1 or Tax 1  
98  
Taxable Total 2  
2
3
4
5
6
7
8
T
99  
VAT 2 or Tax 2  
100  
101  
102  
103  
104  
105  
106  
107  
108  
109  
110  
111  
112  
113  
114  
115  
116  
117  
118  
119  
120  
121  
122  
123  
124  
125  
126  
127  
128  
129  
130  
Taxable Total 3  
VAT 3 or Tax 3  
Taxable Total 4  
VAT 4 or Tax 4  
Taxable Total 5  
VAT 5 or Tax 5  
Taxable Total 6  
VAT 6 or Tax 6  
Taxable Total 7  
VAT 7 or Tax 7  
Taxable Total 8  
VAT 8 or Tax 8  
L
VAT Total  
N . N S  
Net Sale Without Tax  
Tax-exempt Customer  
VAT 1 or Tax 1 Exempt  
VAT 2 or Tax 2 Exempt  
VAT 3 or Tax 3 Exempt  
VAT 4 or Tax 4 Exempt  
VAT 5 or Tax 5 Exempt  
VAT 6 or Tax 6 Exempt  
VAT 7 or Tax 7 Exempt  
VAT 8 or Tax 8 Exempt  
Sales Item Count per Customer  
Sales Amount per Customer  
No-Sale Counter  
V
V
V
V
V
V
V
V
V
I
A
A
A
A
A
A
A
A
A
T
L
T
T
T
T
T
T
T
T
T
E
E
E
E
E
E
E
E
E
E
/
X
X
X
X
X
X
X
X
X
C
C
L
1
2
3
4
5
6
7
8
M
U
U
E
S
S
T
N
C
C
V
M
/
O
L
S
A
S
I
A
R
I
[C] key Counter  
E
N
L
Consignment Counter  
Validation Counter  
Money Declaration Counter  
-- vacant --  
O
A
.
G
C
N
T
C
T
R
R
D
C
R
6-152  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.36 Key Status Programming  
6.36 Key Status Programming  
Various selective statuses of media keys and other function keys are programmed here.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] five times then [Enter].  
6 OTHER” is selected.  
or  
Depress [6].  
Depress [] twice then [Enter].  
3 KEY FUNCTION” is selected.  
or  
Depress [3].  
Move the cursor on to a key name to be  
programmed with the [] or [] key,  
then depress [Enter].  
Move the cursor on to a bit No. to be  
programmed with the [] or [] key,  
then select the status with the [] or  
[] key.  
[Enter]  
[End]  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
3) Example)  
To change Bit No. 2 status of Key Code 3 ([CHK TEND]) from SET to RESET.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “6 OTHER”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
five times.  
6 OTHER” is selected.  
Depress the [6] or [Enter] key.  
(continued on the next page)  
6-153  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.36 Key Status Programming  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “3 KEY  
FUNCTION”.  
Depress the [] key twice.  
3 KEY FUNCTION” is selected.  
Depress the [3] or [Enter] key.  
The cursor is moved on to “03 CHECK”.  
Depress the [] key twice.  
03 CHECK” is selected.  
Depress the [Enter] key.  
(Key Code 3 “CHECK” is selected.)  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Depress the [] key, then depress the  
[] key.  
The Bit Nos. currently programmed are  
displayed on the 7-segment numeric display.  
By the [] key depression, Bit No. 2 status  
is changed from “Y” to “N”.  
Depress the [Enter] key.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this programming.  
31-10-2005 MON #3001  
KEY STATUS  
#03----------------------------7  
0033 13:27TM  
6-154  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.36 Key Status Programming  
Key Status Table (Key Code 1 to 20)  
Bit No.  
Function  
SET  
TOTAL-only key  
RESET  
1
2
3
4
5
6
7
8
1
2
TOTAL-only  
If both SET or RESET:  
TOTAL and TENDER  
TENDER-only  
-- vacant bit --  
TENDER-only key  
SHORT TENDERING  
OVER TENDERING  
-- vacant bit --  
Prohibited  
Prohibited  
Allowed  
Allowed  
NO-PURCHASE CASHING  
FINALIZING R/A ITEMS  
Allowed  
Prohibited  
Allowed  
Free  
Prohibited  
Compulsory  
CONSIGNMENT  
-- vacant bit --  
DRAWER OPEN AFTER THE KEY  
OPERATION (see NOTE below)  
3
Not Open  
Open  
Key  
Key Name  
[AT/TL]  
1
2
3
4
5
6
7
8
1
2
3
Code  
1
2
R
R
R
R
R
R
R
R
R
R
R
R
R
3
R
S
R
R
S
S
S
S
S
S
R
S
S
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
S
R
R
R
R
R
S
R
R
R
R
R
R
R
R
R
S
R
R
S
S
S
S
S
[CHK TEND]  
[CRT]  
4
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
5
6
7
[MISK TEND]  
[CPN]  
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
[CREDIT 1]  
[CREDIT 2]  
[CREDIT 3]  
[CREDIT 4]  
[CREDIT 5]  
NOTE: Regardless of this bit status selection, the drawer opens on over-tendering operation, but does not open  
on short-tendering operation.  
Description of symbol in the above table:  
R
S
= RESET Status  
= SET Status  
Standard Bit status selection auto-preset after a RAM Clear.  
Those bits marked with either “R” or “S” may be RESET or SET according to your requirements.  
= Bit not applicable to the key (Those bits can be SET or RESET.)  
6-155  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.36 Key Status Programming  
Key Status Table (Key Code 21 to 42)  
Bit No.  
Function  
SET  
RESET  
1
2
3
4
5
6
7
8
-- vacant bit --  
MGR INTERVENTION (in REG mode)  
ADD-ON TAX/VAT STATUS  
-- vacant bit --  
Compulsory  
All Taxes Taxable  
Free  
Non-taxable  
-- vacant bit --  
-- vacant bit --  
-- vacant bit --  
-- vacant bit --  
Key  
Key Name  
[ - ] (Disc)  
1
2
3
4
5
6
7
8
Code  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
R
R
R
S
S
S
[VND CPN]  
[STR CPN]  
-- vacant --  
[% I]  
R
R
R
S
S
[% II]  
[RTN MDSE]  
-- vacant --  
[VOID]  
R
-- vacant --  
[PO]  
R
R
R
R
[NS]  
[PB-]  
[EX]  
-- vacant --  
[ALL VOID]  
-- vacant --  
-- vacant --  
-- vacant --  
[1st PRICE]  
[2nd PRICE]  
[3rd PRICE]  
R
R
R
R
Key Codes 43 to 45 are vacant.  
NOTE: If RESET status is selected for the [STR CPN] key, the key will always be non-taxable regardless of the  
department tax status.  
Description of symbol in the above table:  
R
S
= RESET Status  
= SET Status  
Standard Bit status selection auto-preset after a RAM Clear.  
Those bits marked with either “R” or “S” may be RESET or SET according to your requirements.  
= Bit not applicable to the key (Those bits can be SET or RESET.)  
6-156  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.37 Cash Tender key Preset Amount Setting  
6.37 Cash Tender Key Preset Amount Setting  
A maximum of 6-digit amount is preset to the Cash Key ([CASH 1] to [CASH 3]).  
When depressing the cash key with preset amount in a registration operation, it will be processed as a tendering  
operation of the preset amount.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] five times then [Enter].  
6 OTHER” is selected.  
or  
Depress [6].  
Depress [] three times then [Enter].  
4 CASH KEY AMOUNT” is selected.  
or  
Depress [4].  
Preset amount: Max. 6 digits (0 to 999999) (See NOTE below.)  
Input a preset amount of the [CASH 1].  
[Enter]  
Input a preset amount of the [CASH 2].  
[Enter]  
Preset amount: Max. 6 digits (0 to 999999) (See NOTE below.)  
Preset amount: Max. 6 digits (0 to 999999) (See NOTE below.)  
Input a preset amount of the [CASH 3].  
[Enter]  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE: When inputting “0”, the preset amount will be reset. An operation of the cash key of which preset  
amount is reset may cause an error in a registration transaction.  
6-157  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.37 Cash Tender key Preset Amount Setting  
3) Example  
To preset €10000,00 to the [CASH 1] key and €10,00 to the [CASH 2] key.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “6 OTHER”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
five times.  
6 OTHER” is selected.  
Depress the [6] or [Enter] key.  
Depress the [] key three times.  
Depress the [4] or [Enter] key.  
The cursor is moved on to “4 CASH KEY  
AMOUNT”.  
4 CASH KEY AMOUNT” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Input 100000, then depress the [Enter]  
key.  
(The amount 1000,00 is preset to the  
[CASH 1] key.)  
Input 1000, then depress the [Enter]  
key.  
(The amount 10,00 is preset to the  
[CASH 2] key.)  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
31-10-2005 MON #3001  
CASH PRICE  
01 CASH  
02 CASH  
1000,00  
10,00  
0034 13:29TM  
6-158  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.38 Drawer Warming Time Setting  
6.38 Drawer Warning Time Setting  
This operation sets the number of seconds as the period of time for the cash drawer remaining open until the  
alarm buzzer is generated to warn operator to close the drawer.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] five times then [Enter].  
6 OTHER” is selected.  
or  
Depress [6].  
Depress [] four times then [Enter].  
5 DRW WARNING TIME” is selected.  
or  
Depress [5].  
Input a numeriv value of time to start  
the drawer warning buzzer.  
Max. 2 digits: 1 to 99 (seconds)  
This programming is ended. A long receipt is issued and the  
display returns to Main Menu screen.  
[End]  
NOTES:  
1. The value of 0 second cannot be set. (To cancel the drawer warning function, reset the warning option  
itself.)  
2. After a RAM Clear, the value of 15 seconds is set as the default setting.  
3. The setting here is effective only when the following are both selected in the system option programming:  
Address No. 27 - Bit No. 1 SET: Drawer-close compulsory  
Address No. 27 - Bit No. 2 SET: Drawer warning alarm ACTIVE  
4. The drawer warning error is cleared only by closing the drawer. This error cannot be cleared by turning the  
Mode Lock to any position.  
5. The drawer warning time is processed only in REG, MGR, and modes.  
6-159  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.38 Drawer Warming Time Setting  
3) Example  
To set 30 seconds for the drawer warning time.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “6 OTHER”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
five times.  
6 OTHER” is selected.  
Depress the [6] or [Enter] key.  
Depress the [] key four times.  
Depress the [5] or [Enter] key.  
Input 30.  
The cursor is moved on to “5 DRW  
WARNING TIME”.  
5 DRW WARNING TIME” is selected.  
(The drawer warning time is set to 30  
seconds.)  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #3001  
DRAWER WNG  
30  
0035 13:31TM  
6-160  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.39 Special Rounding Process Setting, 1-digit type  
6.39 Special Rounding Process Setting, 1-digit type  
For Special Rounding and Denmark/Australia rounding, the pre-rounded value of the least effective digit and the  
post-rounded value are set here. This operation is effective when the option “Special Rounding ACTIVE” and “1  
digit subject to Special Rounding” are selected (System Option Address No. 33, Bit No. 3 SET & Bit No. 4  
RESET).  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] five times then [Enter].  
6 OTHER” is selected.  
or  
Depress [6].  
Depress [] five times then [Enter].  
6 ROUND TBL 1 DIGIT” is selected.  
or  
Depress [6].  
Maximum value of the range of the digit  
subject to round (1 digit)  
+
*
Maximum value of the range of the digit subject to round: 0 to 9  
Post-rounded value: 00 to 09  
Post-rounded value (2 digits)  
[Enter]  
[End]  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
*: Repeat for the next break entries (max. 10 breaks).  
NOTES:  
1. The values shown in the example below are default setting values after a RAM Clear.  
2. When the “Post-rounded Value” is to be 10 (i.e. the final break point), the break entry is automatically set  
(refer to the example below.). Therefore, it does not need to be entered. Entering a value larger 9 for the  
Post-rounded Value will not cause an error. However, the rounding process will occur only on the least  
effective digit in sales entries.  
3. A maximum of 10 breaks can be programmed.  
3) Example  
To set the following rounding table:  
Pre-rounded value of the  
Post-rounded value  
least effective digit  
0 to 2  
3 to 7  
8 to 9  
0 (=00)  
5 (=05)  
10  
Ignore in setting  
6-161  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.39 Special Rounding Process Setting, 1-digit type  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “6 OTHER”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
five times.  
6 OTHER” is selected.  
Depress the [6] or [Enter] key.  
Depress the [] key five times.  
Depress the [6] or [Enter] key.  
The cursor is moved on to “6 ROUND TBL 1  
DIGIT”.  
6 ROUND TBL 1 DIGIT” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Input 200, then depress the [Enter]  
key.  
Input 705, then depress the [Enter]  
key.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #3001  
ROUNDING1  
200  
705  
0036 13:33TM  
6-162  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.40 Special Rounding Process Setting, 2-digit type  
6.40 Special Rounding Process Setting, 2-digit type  
For Special Rounding and Denmark rounding, the pre-rounded value of the two least effective digit and the post-  
rounded value are set here. This operation is effective when the option “Special Rounding ACTIVE” and “2 digits  
subject to Special Rounding” are selected (System Option Address No. 33, Bit No. 3 SET & Bit No. 4 SET).  
CONDITION  
OPERATION  
Any time outside a sale  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] five times then [Enter].  
6 OTHER” is selected.  
or  
Depress [6].  
Depress [] six times then [Enter].  
7 ROUND TBL 2 DIGITS” is selected.  
or  
Depress [7].  
Maximum value of the range of the digit  
subject to round (2 digits)  
+
*
Maximum value of the range of the digit subject to round: 00 to 99  
Post-rounded value: 00 to 99  
Post-rounded value (2 digits)  
[Enter]  
[End]  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
*: Repeat for the next break entries (max. 10 breaks).  
NOTES:  
1. When the “Post-rounded Value” is to be 100 (i.e. the final break point), the break entry is automatically set  
(refer to the example below). Therefore, it does not need to be entered. Entering a value larger 99 for the  
Post-rounded value will not cause an error. However, the rounding process will occur only on the two least  
effective digits in sales entries.  
2. A maximum of 10 breaks can be programmed.  
3. Values for Sweden rounding are set after performing a RAM Clear.  
4. Example of Sweden rounding  
For the Sweden rounding, the amount total is rounded as shown below.  
Pre-rounded value of the  
two least effective digits  
Post-rounded value  
0 to 24  
25 to 74  
75 to 99  
00  
50  
100  
6-163  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.40 Special Rounding Process Setting, 2-digit type  
Example of Denmark rounding  
For the Denmark rounding, the amount total is rounded as shown below.  
Pre-rounded value of the  
two least effective digits  
Post-rounded value  
0 to 12  
13 to 37  
37 to 62  
63 to 87  
88 to 112  
00  
25  
50  
75  
100  
3) Example  
To set the Denmark rounding.  
Pre-rounded value of the  
two least effective digits  
Post-rounded value  
00  
25  
50  
75  
100  
0 to 12  
13 to 37  
37 to 62  
63 to 87  
88 to 112  
Ignore in setting  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “6 OTHER”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
five times.  
6 OTHER” is selected.  
Depress the [6] or [Enter] key.  
Depress the [] key six times.  
Depress the [7] or [Enter] key.  
The cursor is moved on to “7 ROUND TBL 2  
DIGITS”.  
7 ROUND TBL 2 DIGITS” is selected.  
While ? is shown on the upper-right corner  
of the LCD display screen, the [?] key  
depression results in that the following  
guidance message appears on the LCD  
display.  
Input 1200, then depress the [Enter]  
key.  
(continued on the next page)  
6-164  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.40 Special Rounding Process Setting, 2-digit type  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
Input 3725, then depress the [Enter]  
key.  
Input 6250, then depress the [Enter]  
key.  
Input 8775, then depress the [Enter]  
key.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #3001  
ROUNDING2  
1200  
3725  
6250  
8775  
0037 13:35TM  
6-165  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.41 Number of Receipt Print Buffer Line Setting  
6.41 Number of Receipt Print Buffer Line Setting  
The number of receipt print buffer line is set here. When it reaches the set value, only a receipt print operation  
starts. This setting is effective only in REG, MGR, and - modes or programming operation.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] five times then [Enter].  
6 OTHER” is selected.  
or  
Depress [6].  
Depress [] seven times then [Enter].  
8 RCT PRINT BUFFER” is selected.  
or  
Depress [8].  
Input the Number of receipt print buffer line  
to be set.  
Max. 2 digits: 1 to 50  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTE: The Number of receipt print buffer line is set to 50 as default setting after performing a RAM Clear.  
3) Example  
To set the Number of receipt print buffer line is 30 lines.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “6 OTHER”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
five times.  
6 OTHER” is selected.  
Depress the [6] or [Enter] key.  
(continued on the next page)  
6-166  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.41 Number of Receipt Print Buffer Line Setting  
(continued from the previous page)  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “8 RCT PRINT  
BUFFER”.  
Depress the [] key seven times.  
8 RCT PRINT BUFFER” is selected.  
Depress the [8] or [Enter] key.  
Number of receipt print buffer line: max. 2  
digits (1 to 50)  
Input 30.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #3001  
R PR BUFFER  
RECEIPT BUF  
30  
0038 13:37TM  
6-167  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.42 Serial No. Setting  
6.42 Serial No. Setting  
A maximum of 8-digit serial No. is set here. The serial No. will be printed on the Daily and GT Financial  
Read/Reset Reports.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: SET  
1) Menu Tree  
2) Operation Flowchart  
ECR is being outside a sale and in SET mode.  
Main Menu  
Depress [] five times then [Enter].  
6 OTHER” is selected.  
or  
Depress [6].  
Depress [] eight times then [Enter].  
9 SERIAL NO.” is selected.  
or  
Depress [9].  
Max. 8 digits  
Input a Serial Number.  
This setting is ended. A long receipt is issued and the display  
returns to Main Menu screen.  
[End]  
NOTES:  
1. When inputting 0, the serial No. will be reset. (None of serial No. is printed on the reports.)  
2. The serial No. is always printed on the reports with an 8-digit value. If the serial No. 1 is set, ”00000001” is  
printed on the reports.  
6-168  
6. TERMINAL FILE PROGRAMMING  
EO3-11106  
6.42 Serial No. Setting  
3) Example  
To set the serial No. 12345678.  
Operation  
LCD Display  
Remarks  
The cursor is moved on to “6 OTHER”.  
When the ECR is being outside a sale  
and in SET mode, depress the [] key  
five times.  
6 OTHER” is selected.  
Depress the [6] or [Enter] key.  
Depress the [] key eight times.  
Depress the [9] or [Enter] key.  
Input 12345678.  
The cursor is moved on to “9 SERIAL NO.”.  
9 SERIAL NO.” is selected.  
A long receipt is issued and the display  
returns to Main Menu screen.  
The [End] key depression allows the  
ECR to end this setting.  
TECSTORE  
1343 PEACH DRIVE  
PHONE: 87-6437  
Open 8:00am to 7:00pm  
Closed: every Wednesday  
31-10-2005 MON #3001  
SERIAL NO.  
#12345678  
0039 13:39TM  
6-169  
7. VERIFICATION OF PROGRAMMED DATA  
EO3-11106  
7. VERIFICATION OF PROGRAMMED DATA  
7. VERIFICATION OF PROGRAMMED DATA  
The programmed data entered in the preceding chapter can be read for verification purposes.  
The print format of each program reading is almost the same as on the program receipt, except that “X” is printed  
instead of printing Program Name.  
Any time outside a sale  
CONDITION  
OPERATION  
Mode Lock: X or SET  
1. Turn the Mode Lock to the X or SET position with the MGR key.  
2. In X mode, move the cursor on to “3 PROGRAM DATA READ” which is displayed on the LCD display with  
the [] key, then depress the [Enter] key.  
In SET mode, move the cursor on to “7 PROGRAM DATA READ”, then depress the [Enter] key.  
3. PROGRAM DATA READ menu is shown on the next page. Move the cursor on to a desired item to be  
verified with the [] key, then depress the [Enter] key.  
4. The currently programmed data is printed both on the receipt and on the journal.  
NOTE: On depressing the [Enter] key, the programmed data will be printed. To abort printing once started,  
depress the [ITEM CORR] or [VOID] key. The reading operation is immediately stopped halfway.  
Example)  
To verify the preset rates of the [%-] and [%+] keys in X mode.  
1. When the ECR is being outside a sale and in X mode, depress  
the [] key twice to move the cursor on “3 PROGRAM DATA  
READ”.  
2. Depress the [3] or [Enter] key.  
3. Depress the [] key three times to move the cursor on to “4  
RATE, LIMIT AMOUNT”.  
4. Depress the [4] or [Enter] key.  
5. The [1] or [Enter] key depression results in printing.  
31-10-2005 MON #3001  
X
RATE  
%-  
5%  
0040 13:41TM  
7- 1  
7. VERIFICATION OF PROGRAMMED DATA  
EO3-11106  
7. VERIFICATION OF PROGRAMMED DATA  
PROGRAM DATA READ menu  
X mode  
1 DAILY  
2 GT  
3 PROGRAM DATA READ  
4 OTHER ITEMS  
X
0
1 MESSAGES  
1 COMMERCIAL MESSAGE  
SET mode  
4 RATE, LIMIT AMOUNT SET  
5 BASIC  
6 OTHER  
7 PROGRAM DATA READ  
2 FOOTER MESSAGE  
3 STORE MESSAGE  
0
2 MAMES  
1 DP GROUP NAME  
2 CASHIER NAME  
3 SALESPERSON NAME  
4 FINANCIAL ITM NAME  
5 PRINT ITEM NAME  
6 DISPLAY ITEM NAME  
7 ERROR ITEM NAME  
8 X/Z REPORT NAME  
9 DISP MENU  
0 MESSAGES  
3 DP/PLU  
1 DP SETTING  
1 DP SETTING  
2 DIGIT LIMIT(PRICE)  
2 PLU SETTING  
1 ALL PLU  
2 ZONE PLU  
3 PLU PRICE SETTING  
1 ALL PLU  
2 ZONE PLU  
4 ASSIGN TO KEYBOARD  
4 RATE, LIMIT AMOUNT  
1 %- RATE(%-/%+)  
2 VAT/TAX RATE  
3 CUR EXCHANGE RATE  
4 DISC AMT LIMIT  
5 BASIC  
1 HOURLY RANGE  
2 KEY-IN TONE  
6 OTHER  
1 REPORT PRINT ITEM  
2 SYSTEM OPTION  
3 KEY FUNCTION  
4 CASH KEY AMOUNT  
5 DRW WARNING TIME  
6 ROUND TBL 1 DIGIT  
7 ROUND TBL 2 DIGITS  
8 RTC PRINT BUFFER  
7- 2  

Vivitar DVR 910HD User Manual
Vita Mix XTG012 User Manual
Toshiba Car Video System 23HLV87 User Manual
Sony VCL HG0737C User Manual
Sony HDR TG7VE User Manual
Sony CFD S28 User Manual
Sony 500MM F8 REFLEX SAL500F80 User Manual
Sony 3 280 847 1100000000#User Manual
Samsung SCX 300WM User Manual
Samsung HMX Q100UP User Manual