Teleflex Marine Boating Equipment KE 4A User Manual

Morse KE-4a controls  
(electronic control  
— each lever controls  
throttle AND shift)  
The KE-4 set the standard for reliability  
in marine electronic controls. Its  
simplicity and proven design make it the  
choice for most multi-station/multi-engine  
control pleasure and work boats. KE-4a  
controls are available in either single or twin  
lever binnacle mount versions for single or  
premium  
multiple stations and up to two engines.  
engine control  
Applications:  
Electronic stand-alone controls are ideal  
for larger, multi-station boats, especially  
those applications in which a mechanical  
control cannot deliver the desired feel and  
performance. For nearly all engine types.  
(accepts these cables:)  
Universal 3300/33C Types  
Features:  
Use KE-4a if . . .  
Works with most engines: outboard, stern  
drive or inboard.  
• There are more than 2 stations.  
• Throttle and Shift are actuated  
mechanically (KE-4a has no electronic  
throttle interface).  
• Trolling valve control required.  
• Throttle Sync only is needed.  
• Electrical system is 12 or 24 volt.  
• Hand-held remote desired.  
Single or twin engine control; dual function  
for each lever.  
Up to 4 control heads.  
Optional hand-held remote control: great  
for docking and fishing!  
Built-in Station Select switch.  
Engine Sync option available.  
Gear shift delay available.  
• CANBus interface is not needed.  
(If needed, see i6000.)  
Neutral engine warm-up provision.  
Mechanical backup (easy to use “get  
home” system).  
Built-in overload protection & diagnostics.  
Visual failure alarm standard (audio alarm  
optional).  
NOTE: When properly installed, these engine  
controls will connect to outboard, stern drive and  
inboard engines, utilizing an electronic interface,  
universal 3300/33C type cables and appropriate  
engine connection kits.  
Uses standard 3300/33C type control  
cables on throttle/shift actuator.  
Easy to install. Plug-in connectors.  
12 and 24 volt capability.  
Meets/exceeds all applicable industry  
standards.  
The boat's original mechanical control and 3300/33C  
cables (if so equipped) can be reused for the "get home"  
(emergency back-up) feature. The back-up control does not  
have to be mounted, but be certain that the cables used  
with this control are long enough so that the control can be  
operated from the steering station.  
224  
Morse KE-4a controls  
Basic KE-4a System Overview:  
The following schematic shows elements of the KE-4a control system in a typical twin engine/twin station application.  
For part numbers associated with the items depicted below, please see the page at right.  
226  
electronic control: mechanical throttle/shift, up to 4 stations  
KE-4a System Components:  
The following chart lists components of the KE-4a control system for each application. For an illustration of each  
component, please see the page at left.  
Required for  
Single engine  
Required for  
Two engine  
No. Name  
Part No.  
Notes  
No. of Station  
1st 2nd 3rd 4th  
No. of Station  
1st 2nd 3rd 4th  
1
2
Control Head-Single Engine  
Control Head-Twin Engine  
Control Unit  
NM0511-00  
NM0510-00  
1
-
2
-
3
-
4
-
-
1
-
2
-
3
-
4
24V model  
12V model  
Throttle/Shift Actuator  
Communication  
NM0478-00  
NM0477-00  
NM0165-00  
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
2
2
3
4
Harness  
Harness -  
Remote  
Control  
5m  
4m  
6m  
NM0619-05  
NM0616-04  
NM0616-06  
NM0616-08  
NM0616-10  
NM0616-12  
NM0616-14  
NM0616-16  
NM0616-18  
NM0616-20  
NM0616-22  
NM0616-24  
NM0616-26  
NM0616-28  
NM0616-30  
NM0616-32  
NM0616-34  
NM0616-36  
NM0616-38  
NM0616-40  
NM0616-50  
NM0414-28  
NM0414-33  
-
-
-
-
1
1
1
1
5
8m  
10m  
12m  
14m  
16m  
18m  
20m  
22m  
24m  
26m  
28m  
30m  
32m  
34m  
36m  
38m  
40m  
50m  
5m  
1
2
3
4
2
4
6
8
6
7
8
9
Harness -  
Power  
Circuit  
Breaker  
Buzzer  
2
2
2
2
4
4
4
4
10m  
20A  
24V model  
12V model  
NJ0514-00  
NJ0515-00  
NJ0596-00 (replaces NJ0251-00)  
33C  
2
1
2
2
2
3
2
4
4
2
4
4
4
6
4
8
Option  
Option  
Cable  
(actuator)  
33C Supreme  
3300CC TFXTREME  
Use standard Morse 1  
control head  
33C  
2
2
2
2
1
4
2
4
2
4
2
4
2
Specify cable length  
Option  
10 Mechanical Control Head  
(for manual backup operation)  
11 Cable  
1
1
(for manual backup operation)  
33C Supreme  
2
2
2
2
4
4
4
4
Specify cable length  
3300CC TFXTREME  
NOTES:  
Please refer to the NAME OF EACH PART on previous page for the item number in chart above.  
All Wiring harnesses are measured in meters (1 meter = 39.37 inches).  
CC633XX is recommended. Teleflex Control Cables are measured by the foot. XX = Control cable length in feet. For Morse, XXX = inches.  
Using 20 amp circuit breaker NJ0514-00 is strongly recommended.  
227  

Winegard Car Satellite TV System FL5000C User Manual
VistaQuest VQ515 User Manual
Vista Davis & Sanford MAXI605811 User Manual
Turbo Air TBD 3SD User Manual
Triax UFO 100 User Manual
Tiffen Monopod Duo 60" Monopod User Manual
SOYO Car Video System M17GS User Manual
Sony HANDYCAM HDR XR500VE User Manual
Sony Ericsson Bluetooth HBH IS800 User Manual
Samsung VP L 700 User Manual