XTherm™- Type WHP
Job:
Engineer:
Contractor:
Prepared By:
Model:
Water Heaters
Models 1005-2005
Date:
Indoor/Outdoor:
97% Thermal Efficiency at Full Rate; Up to 99% at Part Load
100% Factory Fire Tested
Maximum Outlet Water Temperature: 160°F
Minimum Acceptable Inlet Water Temperature: 50°F
Full Safety Diagnostics with History
Footprint: Less Than 10.8 ft2
Limited Twenty-Five-Year Thermal Shock Warranty
Limited Ten-Year Primary Heat Exchanger Warranty
Limited Five-Year Secondary Heat Exchanger Warranty
Full Electronic Modulation, Constant Ratio 4:1 Turndown
Digital Controller with LCD Display
Status Display Lights
Heat Exchanger
Control (cont.)
Multi-Boiler Digital Temp Controllers
Bronze Headers
ASME HLW Stamped; 160 PSIG
MAWP
Diagnostics Panel with LCD Display,
2 lines, 20 characters
Digital Temperature Control
Water Temperature Sensors (3)
Cold Water Protection
B-36 TempTracker Mod+,
2-4 Water Heaters
B-37 TempTracker Mod+,
5-10 Water Heaters
B-38 TempTracker Mod+,
11-16 Water Heaters
National Board Listed
Cupro Nickel Fin Tubing
ASME Powder-Coated Tube Sheet
Silicone High Temp O-Rings
ASME Pressure Relief Valve
125 PSIG – Standard (Loose)
150 PSI Air Vent, Auto
T&P Gauge (Loose)
Stainless Steel Secondary Heat
Exchanger
Stainless Steel Evaporator Plate
Boiler Pump: Bronze,
120V, 1∅, 60Hz
Burner
Ultra-Low NOx: Less than 20 PPM
(Natural Gas Only)
Options
F-10 Low Water Cut-Off, Remote
Probe
Gas Train
Fuel
I-5
High Limit, Manual Reset,
Adj., 100-200°F
Low Gas Pressure Switch,
Manual Reset
High Gas Pressure Switch,
Manual Reset
Natural Gas
Propane
Zero Governor Regulator
Dual-Seat Combination Valve
Electronic Firing Mode (WHP)
S-1
S-2
HP,
Z-12 Condensate Neutralizer Kit
Construction
Indoor/Outdoor Construction
Front Controls Enclosed
PolyTuf Powder Coat Finish
Rear Connections (Water, Gas, Vent,
Electrical, Comb. Air, Cond. Drain)
Combustion Air Filter
Control
Regulatory Agency Requirements
120V, 60Hz, 1Ø, Power Supply
120/24V 60Hz Transformer
Ignition Module
3-Try – Standard
Single-Try – Option C-6
Hot Surface Ignition (HSI)
Remote Flame Sensor
High Limit Control, Auto Reset
On/Off Power Switch
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switch
Freeze Protection
Design Certified ANSI Z21.10.3/CSA 4.3
Venting
Vent Termination
Outdoor or Indoor, Vertical –
Option D-11
Indoor, Horizontal – Option D-15
Extractor - Optional
By others
Pump Switch
Pump Time Delay
Blocked Condensate Switch
Not required
Catalog No.: 6000.37
Effective: 9-15-08
Replaces: NEW
|