XFyre™- Type H
Condensing Heating Boilers
Models 300-850
Job:
Engineer:
Contractor:
Prepared By:
Model:
Date:
Indoor/Outdoor:
Up to 94% Thermal Efficiency at Full Rate
100% Factory Fire Tested
Maximum Outlet Water Temperature: 210°F
Maximum System Temperature: 200°F
Full Safety Diagnostics with History
Footprint: Less Than 9-1/2 ft2
Limited Twenty-Year Thermal Shock Warranty
Limited Ten-Year Heat Exchanger Warranty
Full Electronic Modulation, Constant Ratio 5:1 Turndown
Soft-Start Modulating Controller with LCD Display
Status and Full Diagnostics Display
Heat Exchanger
ƒ All Stainless Steel Construction
ƒ Gasketless Heat Exchanger Design
ƒ ASME H Stamped
160 PSIG Working Pressure
ƒ National Board Approved
ƒ ASME Pressure Relief Valve
Multi-Boiler System Controllers
B-36 TempTracker Mod+ Digital
Controller, 2-4 Boilers, OA Reset
B-37 TempTracker Mod+ Digital
Controller, 5-10 Boilers, OA Reset
B-38 TempTracker Mod+ Digital
Controller, 11-16 Boilers, OA Reset
Gas Train
ƒ Fuel
Natural Gas
Propane
ƒ Zero Governor Regulator
ƒ Dual-Seat Combination Valve
ƒ Electronic Modulating Firing Mode (H7)
60 PSIG – Standard
Options
PSIG – Optional
ƒ Temperature and Pressure Gauge,
Shipped Loose
Construction
D-21 TruSeal™ Combustion Air Inlet
ƒ Indoor/Outdoor Construction
ƒ Front Controls Enclosed
ƒ PolyTuf Powder Coat Finish
ƒ Rear Connections (Electrical, Gas, Vent,
Combustion Air)
ƒ Top Connections (Water)
ƒ Design Certified ANSI Z21.13/
CSA 4.9
P-
Pump:
Cast Iron
HP, 120V, 1∅, 60Hz
Bronze
Control
S-1
S-2
Low Gas Pressure Switch,
Manual Reset
High Gas Pressure Switch,
Manual Reset
ƒ 120V, 60Hz, 1Ø, Power Supply
ƒ Digital Operating Control with LCD
display.
ƒ Outdoor reset with Indirect Priority
ƒ 0-10 VDC input for BMS
ƒ Cascade up to 8 boilers
ƒ Spark Ignition (IID)
ƒ Remote Flame Sensor
ƒ High Limit, Manual Reset, Fixed,
200ºF
Z-12 Condensate Neutralizer Kit
Venting (PVC-CPVC-Stainless.)
ƒ Vent Termination
Indoor, Vertical – Option D-11
Indoor, Horizontal – Option D-15
Outdoor
Regulatory Agency Requirements
ƒ Auto Limit, Fixed, 210ºF
ƒ Alarm Dry Contact Connection
ƒ On/Off Power Switch
ƒ Flow Switch
ƒ Extractor - Optional
By others
Not required
ƒ Blocked Vent Pressure Switch
ƒ Boiler, DHW & System Pump
Contacts
ƒ Water Temperature Sensors (3)
Burner
ƒ Ultra-Low NOx: Less than 20 PPM
Catalog No.: 2000.17
Effective: 6-22-09
Replaces: New
|
ProMaster LED30 User Manual
Pioneer DVD ROM Drive DVD 103S User Manual
Pioneer Car Stereo System SX 3400 User Manual
Panasonic Car Stereo System PT 50LC13 User Manual
Nikon Coolpix L120 User Manual
Nikon 2204B User Manual
Nikon 2197B User Manual
Manley Labs NEO CLASSIC 300B User Manual
Laney Amplification Car Satellite Radio System HCM160B User Manual
Kenwood Car Stereo System KDC MP146 User Manual