Raypak 302BE 902BE User Manual

Hi Delta® - Type H  
Job:  
Engineer:  
Contractor:  
Prepared By:  
Model:  
Hydronic Heating Boiler  
Models 302BE-902BE  
Date:  
87% Efficiency  
MBTUH Input:  
Indoor/Outdoor:  
Š 100% Factory Fire Tested  
Š Efficiency: 87%  
Š Maximum Outlet Temperature: 230°F  
Š Minimum Non-Condensing Inlet Temperature: 120°F  
Š Thermal Shock Proof Heat Exchanger  
Š Limited Twenty-Year Thermal Shock Warranty  
Š Limited Ten-Year Heat Exchanger Warranty  
Š Diagnostic Center with Fault History  
Š PolyTuf Powder Coated Cabinet  
Š No Combustible Floor Shield Required  
Š Fan-Assisted  
Š Patented Burner Security Blanket  
Heat Exchanger  
Gas Train  
Burner  
ƒ
ƒ
H Stamp  
Headers  
ƒ
ƒ
ƒ
ƒ
ƒ
Manual Gas Shut-Off Valve(s)  
ƒ
Ultra-Low NOx: Less than 30 PPM  
Gas Pressure Regulator  
Safety Shut-Off Valve  
Firing Control Valve  
Firing Mode  
Temperature Controls  
Glass-Lined Cast Iron – Standard  
B-2 Tankstat, Single-Stage (100-200°F)  
B-3 Tankstat, 2-Stage (100-200°F)  
B-6 Aquastat, 2-Stage (100-200°F)  
Bronze – Option A-1  
ASME Inspected and Stamped  
160 PSIG Working Pressure  
National Board Approved  
Fin Tubing  
ƒ
On/Off (H4): Models 302BE  
and 402BE  
2-Stage (H3): Models 302BE -  
902BE  
B-  
TempTracker Digital Controller,  
2-Stage  
ƒ
ƒ
B-  
TempTracker Digital Controller,  
4-Stage  
Copper – Standard  
Cupro Nickel – Option A-3  
ASME Steel Tube Sheet  
Silicone High Temp O-Rings  
Pressure Relief Valve, ASME  
45 PSIG – Standard on Models  
302BE and 402BE  
ƒ
ƒ
Fuel  
Y-241 Electronic Sequencer, 4-Stage  
Y-281 Electronic Sequencer, 8-Stage  
ƒ
ƒ
ƒ
Natural Gas  
Propane Gas  
4” WC Gas Supply Pressure  
G-20  
Options  
C-6 Ignition Module, Manual Reset  
D-21 TruSeal® Direct Vent  
Design Certified ANSI Z21.13/  
CSA 4.9  
F-10 Low Water Cut-Off, Remote Probe  
60 PSIG – Standard on Models  
502BE-902BE  
I-1  
High Limit Control, Auto Reset  
Venting  
ƒ
PSIG – Optional  
P-  
Pump: HP, 120V, 1, 60Hz  
Vent Location  
ƒ
ƒ
Temperature and Pressure Gauge  
Water Connections  
Water Hardness:  
Cast Iron  
Mounted  
GPG  
Bronze  
Loose  
Rear  
Top – Standard  
Rear – Option D-14  
Vent Termination Cap  
Outdoor D-11  
Indoor, Horizontal D-15  
Indoor, Vertical (by others)  
Combustion Air  
In-Line Filter Kit (Recommended  
with Ducted-In Air Only) D-17  
Air Intake Elbow D-16  
Extractor - Optional  
By Others  
Left – Standard  
Right – Option A-6  
ƒ
Front  
P-26 Cold Water Start (See 2000.48)  
S-1 Low Gas Pressure Switch, Manual  
S-2 High Gas Pressure Switch,  
Manual  
X-1 SureRack™ Kit  
X-2 SureRack Add-on  
Controls  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
120V, 60Hz, 1Power Supply  
120/24V 60Hz Transformer  
100% Shutoff/Lockout  
Hot Surface Ignition  
Remote Flame Sensor  
High Limit Control, Manual Reset  
On/Off Power Switch  
Manual Shut-Off, Front-Mounted  
Flow Switch  
Blocked Vent Pressure Switch  
Combustion Air Proving Switch  
Economaster Pump Time Delay  
ƒ
ƒ
Regulatory Agency Requirements  
Not Required  
Construction  
ƒ
ƒ
Indoor/Outdoor Construction  
Enclosed Front Controls  
Catalog No.: 2000.441E  
Effective: 11-15-07  
Replaces: 1-1-07  

Q See QSICB2 User Manual
Philips AQ 4420 User Manual
Philips AQ4140 User Manual
Panasonic SDR H90P User Manual
Panasonic CQ VX777EW User Manual
Nokia BH 202 User Manual
Nikon 1960 User Manual
Kenwood KAC 629S User Manual
Kenwood Car Amplifier KAF S500 User Manual
Kenwood BL650 User Manual