| Panasonic Broadcast   AW-E860N   Menu Information   Adjustment   $ Total pedestal level adjustment   (Use an oscilloscope or a waveform monitor for this   adjustment.)   This step is to adjust the black levels (pedestal levels) of two   or more cameras to be the same.   [ADJUSTMENT by CAMERA]   1. Close the lens.   2. Select Pedestal item in the brightness setting Sub Menu.   (Select [Pedestal] in the [Iris, Shutter, Gain Set] sub   menu in User Mode.)   3. Set the pedestal level to 5 IRE (0.035 V) with the   YES/ABC switch or the NO/BAR switch.   NO/BAR switch   YES/ABC switch   [ADJUSTMENT with RCU (RCB, Hybrid control panel)]   Adjust the pedestal level to 5 IRE with the total pedestal   adjustment.   TOTAL PEDESTAL   -26-   $ Gen-lock adjustment   Phase adjustments must be performed with the camera or   the RCU (RCB) when external synchronizing signals are   supplied to the system in cases where multiple cameras are   used or peripheral devices are connected.   U Horizontal phase control   Observe the waveform of the external synchronizing input   signal (black burst signal) and video output signal on a   two-channel oscilloscope. Then match the horizontal phase   of both signals by adjusting them with the cameras or RCU’s   horizontal phase control.   NO/BAR switch   YES/ABC switch   [ADJUSTMENT with RCU (RCB, Hybrid control panel )]   Use the horizontal phase control.   External gen-lock input signal   (black burst output of special effect   generator)   Video signal   Adjust the horizontal phase   [ADJUSTMENT by CAMERA]   1. Press the NO/BAR switch for over 5 seconds to display   the color bar.   Subcarrier phase   fine control   Horizontal phase   control   2. Select [G/L Adjustment] on the main menu, then select [H   Phase] on the submenu.   3. Adjust the horizontal phase with the YES/ABC and   NO/BAR switch.   Subcarrier phase   coarse control   -27-   Adjustment   Caution:   4. Select [SC Fine] on the sub menu. Perform fine   adjustment with the YES/ABC switch and the NO/BAR   switch.   • When horizontal phase adjustment is required using RCU   (RCB) or hybrid control panel, BAR/CAM switch should be   set to BAR. Horizontal phase cannot be adjusted if the   switch is in the CAM position. After adjustment set   BAR/CAM switch back to CAM.   • When horizontal phase adjustment is moved, color phase   is also moved. Adjust color phase whenever horizontal   phase adjustment is moved.   U Color phase adjustment   Supply the output signal (split color bar) from the color   special effect generator to a color monitor or vectorscope.   Adjust the color phase of the camera.   [ADJUSTMENT with RCU (RCB, Hybrid control panel)]   Use the subcarrier phase coarse adjustment control and   subcarrier phase fine control.   ❈ It is recommended that a vectorscope be used for   maximum accuracy in color phase adjustment.   Color bar of camera   Sprit line   Color bar of special   effects generator   Caution:   • When color phase adjustment is required using RCU   (RCB) or hybrid control panel, BAR/CAM switch should be   set to BAR. Color phase cannot be adjusted if the switch is   in the CAM position. After adjustment set BAR/CAM switch   back to CAM.   • When horizontal phase adjustment is moved, color phase   is also moved. Adjust color phase whenever horizontal   phase adjustment is moved.   [ADJUSTMENT by CAMERA]   1. Press the NO/BAR switch for over 5 seconds for the color   bar mode.   2. Select [G/L Adjustment] on the main menu, then select   [SC Coarse] on the sub menu.   3. Make coarse adjustment with the YES/ABC switch and   the NO/BAR switch.   -28-   Use mode setting   2. Press the MENU switch, ITEM/AWC switch, or NO/BAR   switch to let the desired use mode blink.   MENU switch (A):   $ Use Mode Setting   The camera has four use modes, and various functions for   four use modes have been preset.   The blinking item moves up by one.   ITEM/AWC switch (S), NO/BAR switch (–):   The blinking item moves down by one.   Functions can be set as best suited to each use mode.   • Halogen mode   Suited to indoor shooting, such as at weddings, parties,   lecture meetings, events, etc.   Settings can be changed using a simple menu.   • Fluorescent mode   Suited to indoor shooting under fluorescent lighting.   Settings can be changed using a simple menu.   • Outdoor mode   Suited to outdoor shooting.   Settings can be changed using a simple menu.   • User mode   Settings can be changed using a detail menu.   3. Press the YES/ABC switch.   The blinking use mode comes into effect. After the use   mode setting menu is shown for about 5 seconds, the   camera returns to be ready for operation.   $ Setting by camera   Then, the camera operates in the selected use mode.   1. Turn the camera on while keeping the MENU switch   depressed.   The use mode setting menu shown at right appears on   the monitor screen and one of the use mode blinks.   -29-   Use mode setting   $ Setting by RCU (RCB) or hybrid control   panel   An operation mode is selected depending on the position of   the scene file switch.   Scene File Switch Scene File Switch   Operation mode   Position of   Position of Hybrid   RCU (RCB)   control panel   Halogen Mode   Fluorescent Mode   Outdoor Mode   User’s Mode   1 1 2 3 4 2 3 USER SET   CAMERA   RCU (RCB)   Hybrid control panel   MENU   ITEM/AWC   YES/ABC   NO/BAR   SCENE   FILE switch   SCENE FILE switch   -30-   Menu item setting   U Main menu screen   Main menu of Halogen,   $ Menu item setting   • Each of the four use modes of the camera has a main   menu. (Shown at right)   Fluorescent, Outdoor Mode   • Each item of the main menu has a submenu, which   consists of several settings.   Use mode   Blinking   • These settings have been preset to the optimum values to   suit each use mode, and can be changed to suit actual   shooting conditions.   • They can be set from the camera and RCU (RCB). They   can also be set from the hybrid control panel using the   switches, but the setting items are limited because the   menu is not shown.   Notes:   • Composite signals are output from the video output   regardless of the position ENC/VF of the RCU (RCB) user   set switch.   Main menu of User Mode   • [End] is displayed only in setting from the camera alone.   • [Option Card1] is shown only when an optional card is   inserted into the camera. [Option Card2] is shown only   when an additional card box is equipped with the camera   and then an optional card is inserted into the camera.   -31-   Menu item setting   ❈ If the output signal from camera is color bar, only “G/L,   6. Select [Return] using the MENU switch and ITEM/AWC   switch, then press the YES/ABC switch to return to the   main menu.   Color Bar Set” screen is displayed.   7. After changing the settings, take the following steps.   Camera alone:   Select [End] using the MENU switch and ITEM/AWC   switch and press the YES/ABC switch.   RCU (RCB):   Set the user set switch in the pocket to the OFF position.   The camera will now operate according to the new settings.   CAMERA   RCU (RCB)   USER SET switch   MENU   $ Setting   ITEM/AWC   YES/ABC   NO/BAR   1. From the camera alone:   Keep the MENU switch depressed for 5 seconds or more.   From RCU (RCB):   Set the user set switch in the pocket to the ON position.   The main menu appears on the monitor screen.   2. Each time the MENU switch (A), ITEM/AWC switch (S),   or NO/BAR switch (–) is pressed, the blinking item moves   up or down.   $ Changing the Language setting   The language on the menu screen can be changed from   English to Japanese. (Factory setting: English)   • Halogen, Fluorescent, Outdoor Mode   Select “Japanese” in the “Language” setting in Other Set   submenu.   3. When the YES/ABC switch is pressed after selecting the   desired item to blink, the submenu for the selected item   appears on the screen.   4. Select the desired item to be changed in its settings using   • Use Mode   the MENU switch (A) and ITEM/AWC switch (S).   Select “Japanese” in the “Language” setting in Other Set2   submenu.   5. Press the YES/ABC switch (+) or NO/BAR switch (–) to   change the settings.   -32-   $ Sub menu (Halogen Mode, Fluorescent Mode, Outdoor Mode)   1Brightness Set Display   3G/L, Color Bar Set Display   5Other Set Display   1–––––   2–––––   3–––––   4–––––   5–––––   6––––––   7–––––   8–––––   =–––––   >–––––   ?–––––   @–––––   A––––   G–––––   H–––––   I––––––   J–––––   K–––––   L–––––   M–––––   N–––––   O–––––   2Color Set Display   4Sharpness (DTL) Set Display   9–––––   :–––––   ;–––––   <––––––   B–––––   C––––––   D–––––   E–––––   F–––––   • Settings enclosed in parentheses can be set with the RCU (RCB) switch or VR in RCU (RCB) mode.   • Settings enclosed in [ ] is displayed when the optional card to process video signals (SDI card, etc.) is inserted.   • To return to the initial settings, refer to page 53.   -33-   Menu item setting   R/L cut: About one-third of both the right and left   portions of the screen are excluded from   measurement.   $ Setting and changing of the setting (Halogen   Mode, Fluorescent Mode, Outdoor Mode)   1Brightness Set Display   1 Video Level Adjustment [Picture Level: –50 to +50]   Convergence level of AUTO IRIS/AUTO GAIN UP/ AUTO   ND (ELC) can be adjusted.   4 Auto ND (ELC) Setting [Auto ND (ELC): OFF, ON]   OFF: Luminance is not automatically adjusted by the   electronic shutter.   ON: The electronic shutter is controlled to automatically   adjust the luminance.   2 Detecting Ratio Adjustment   [Light PEAK/AVG: P50 to A50]   The ratio of AUTO IRIS/AUTO GAIN UP/AUTO ND (ELC)   detected peak to average can be adjusted within a   predetermined range.   Notes   • ON is automatically selected when the electronic shutter   (H) on the submenu [Other Set] is set to [Auto ND].   OFF is selected when other than [Auto ND] is selected.   3 Photometric Measurement Method Setting   [Light Area: All, Center, Top cut, BTM cut, R/L cut]   A photometric measurement method can be selected for   AUTO IRIS/AUTO GAIN UP/AUTO ND (ELC).   • ON is selected when the SHUTTER switch is set to   [ELC] in RCU (RCB) mode, and OFF is selected when it   is set to other than [ELC].   All:   All the screen area is measured.   Center: The screen is measured mainly in the center   area, about one-third of both the top and   bottom and one-third of both the right and left   portions of the screen are excluded from   measurement.   Top cut: About one-third of the top part of the screen is   excluded from measurement.   BTM cut: About one-third of the bottom portion of the   screen is excluded from measurement.   SHUTTER switch   RCU (RCB)   -34-   5 Auto Gain Up Control Setting [Auto Gain Up: OFF, ON]   6 AGC Maximum Gain [AGC Max Gain: 6dB, 12dB,   18dB, 24dB, N/Eye L, N/Eye H]   OFF: The light quantity is not adjusted   automatically.   ON: The light quantity is adjusted automatically.   The maximum to which the gain can be increased   using the auto gain up function is selected by the   AGC maximum gain setting (6).   This is used to set the maximum amount to which the   gain can be increased when “ON” has been selected as   the auto gain up setting (5).   7 Manual Gain Up Control Setting   [Manu Gain Up: 0 dB to 30 dB, N/Eye L, N/Eye H]   Manual setting is possible only when the Auto Gain Up   control is in the OFF position.   Notes   • In case of settings on the camera alone or when the iris   switch on the RCU (RCB) is at [AUTO], the Auto Gain   Up control may not operate if the lens iris switch is in   the manual position.   0 dB:   0 dB should be selected in normal cases.   1 dB to 30 dB: Use this range if sufficient video output   cannot be obtained even when the lens   iris is opened in shooting dark scenes.   N/Eye L (Night Eye L):   • When the AGC switch on the hybrid control panel is set   to AGC, the Auto Gain Up control operates in the HIGH   position.   Use this mode if sufficient video output   cannot be obtained even if 30 dB gain up   should be selected.   AGC switch   N/Eye H (Night Eye H):   Use this setting if it is not possible to   achieve a satisfactory video output even   at the Night Eye L setting.   Hybrid control panel   -35-   Menu item setting   Notes   2Color Set Display   • Only 0 dB, 9 dB, or 18 dB can be selected in case of   using the RCU (RCB).   9 Chroma Level Adjustment [Chroma Level: –3 to +3]   Chroma Level can be decreased or increased to any of   three levels each.The signal output to the optional card   cannot be adjusted.   • 0 dB when the manual GAIN switch on the hybrid   control panel is at LOW, 9 dB when it is at MID, or   18 dB when it is at HIGH.   : Skin Color Adjustment [Flesh Tone: –3 to +3]   Skin color can be decreased or increased to any of three   levels each.   Manual GAIN switch   ; White Balance Setting   [White Bal: ATW, AWC A, AWC B, 3200K, 5600K]   ATW: The white balance is automatically adjusted to   be always right.   Hybrid control panel   AWC A, AWC B:   Once the white balance is adjusted with the   ITEM/AWC switch on the back of the camera, it   is no longer necessary to set the white balance   again if you simply select AWC A or AWC B,   provided that the camera is used under the same   conditions.   8 Black Level Setting [Pedestal: –150 to +150]   The black level (pedestal) of the luminance (Y) signal can   be set. Used in adjusting the black levels of two or more   cameras.   Fine color adjustment can be made after setting   AWC by red/blue gain adjustment in user mode   or from the RCU (RCB).   3200K: The white balance is adjusted to 3200K   illumination.   -36-   5600K: The white balance is adjusted to 5600K   3G/L, Color Bar Set Display   illumination.   = Horizontal Phase Adjustment [H Phase: –206 to +49]   Horizontal phase can be adjusted when a genlock signal   is supplied.   Note   Neither 3200K nor 5600K can be set from the RCU   (RCB) or the hybrid control panel.   > Subcarrier Phase Coarse Adjustment   [SC Coarse: 1, 2, 3, 4]   Coarse adjustment of subcarrier phase can be made   when a genlock signal is supplied.   < ATW Speed Setting   [ATW Speed: Slow 2, Slow 1, Mid, Fast 1, Fast 2]   ATW Speed can be set.   ? Subcarrier Phase Fine Adjustment   [SC Fine: –511 to +511]   Fine adjustment of subcarrier phase can be made when a   genlock signal is supplied.   @ Color Bar Setup Setting   [Color Bar Set: 0.0 IRE, 7.5 IRE]   The setup level of color bar can be adjusted.   A Color Bar Setup Setting for the optional cards   [Color Bar Set2: 0.0 IRE, 7.5 IRE]   This menu is displayed when the optional card to process   video signals is inserted.   The setup level of color bar to output to the optional card   can be adjusted.   Set 0.0 IRE when the SDI card is inserted.   -37-   Menu item setting   D Noise Suppress Level Setting   [Noise Suppress: OFF, Low, High]   Screen noise can be reduced when Detail Level setting is   at High or Low.   4Sharpness (DTL) Set Display   B Detail Select Setting [DTL Select: Sharpness, Super DTL]   If contour correction is not sufficient at the Sharpness   position when Detail Level setting is set to Low or High,   select the Super DTL position.   E Clean DNR Setting [Clean DNR: OFF, Low, High]   Note   This enables the clean DNR effect to be selected.   Neither Sharpness nor Super DTL is valid for contour   correction if Detail Level setting is in the OFF position.   F Flesh Noise Suppress Level Setting   [Flesh Noise Sup.: OFF, Low, High]   Flesh noise is suppressed in two steps when the Detail   Level Setting is at High or Low.   C Detail Level Setting [Level: OFF, Low, High]   Detail level can be adjusted when Detail Select setting is   at Sharpness. Super DTL level can be adjusted when it is   at Super DTL.   In case of using the RCU (RCB), the above can be   adjusted with the contour correction switch (DTL).   RCU (RCB)   DTL switch   -38-   I Electronic Shutter Synchro Scan Setting   [Synchro Scan: 60.34Hz to 15.75kHz]   5Other Set Display   G Contrast Adjustment   This setting is possible only when Electronic Shutter   setting is at S/Scan.   Horizontal bar noise can be reduced by synchro-scan   adjustment in shooting workstation scenes, for example.   ❈ For luminance settings at each shutter speed and   synchro-scan shutter speed, refer to the table below.   [Contrast (Gamma): Low, Mid, High]   Contrast can be adjusted to any of three levels.   H Electronic Shutter Setting [Shutter Speed: OFF, 1/100   to 1/10000, S/Scan, Auto ND]   Shutter Speed   Synchro-scan   Required luminance ratio   OFF:   Electronic shutter is turned off.   OFF   — 1 2 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000:   Electronic shutter operates at one of these   speeds as selected.   1/100   100.3 Hz   250.0 Hz   492.2 Hz   984.4 Hz   1.969 kHz   3.938 kHz   7.875 kHz   1/250   4 S/Scan (Synchro Scan):   1/500   8 Electronic shutter operates at the speed set   with the electronic shutter synchro-scan setting.   Auto ND: Electronic shutter is controlled to automatically   adjust the luminance.   1/1000   1/2000   1/4000   1/10000   16   32   64   160   Notes   J CCD Read Out Mode Setting   • In case of using the RCU (RCB), none of the shutter speeds   — 1/250, 1/2000, 1/4000, and 1/10000 can be selected.   [V Resolution: Normal, Fine]   Normal: Normal image. (CCD storage will be by field   • In case of using the hybrid control panel, only OFF,   1/100, or Auto ND (ELC) can be selected.   storage.)   Fine:   Vertical resolution increases. (Vertical resolution   is raised without increasing residual images by   frame storage and Electronic shutter.)   Normal is recommended for general use   because sensitivity will decrease at the Fine   setting.   • If the lens iris switch is at M (Manual) when operating the camera   alone or when the iris switch on the RCU (RCB) is at AUTO, Auto   ND may not function. Set the lens iris switch to A (Auto).   • Flickering may increase at Auto ND under fluorescent lights.   • Auto ND is automatically selected if Auto ND (ELC)   setting is set to ON.   -39-   Menu item setting   K PC Control Access Speed Setting   [Baud Rate: 1200bps, 2400bps, 4800bps, 9600bps]   Select a communication speed in controlling the camera   from the computer.   O Language Selection [Language: English, Japanese]   English: Menu screen is displayed in English.   Japanese: Menu screen is displayed in Japanese.   L Component Output Setting   [Component: RGB, Y/Pr/Pb, Y/C]   This enables RGB, Y/Pr/Pb or Y/C to be selected as the   component signals which are to be output from the I/F   REMOTE connector.   M Aspect Ratio Selection [Aspect Ratio: 16:9, 4:3]   Aspect ratio can be selected from 16:9 or 4:3.   N Fan Setting [Fan SW: OFF, Auto]   OFF: Select this setting to stop the fan when its   operating sound is found to be bothersome in a   studio or other such environment.   Auto: The temperature is detected automatically, and   the fan starts operating when the temperature   exceeds approx. 95°F (35°C).   Under normal circumstances, the “Auto” setting is   used.   -40-   $ Sub menu (User Mode)   6Iris, Shutter, Gain Set Display 8G/L, Color Bar Set Display   9Detail Set Display   P–––––   Q–––––   R–––––   S–––––   T–––––   U–––––   V–––––   W––––––   ]–––––   ^–––––   _–––––   `–––––   a––––   b–––––   c–––––   d–––––   e–––––   f–––––   g–––––   h–––––   i–––––   j–––––   k–––––   l–––––   m–––––   7Color Set Display   X–––––   Y–––––   Z––––––   [–––––   \–––––   -41-   Menu item setting   :Color Matrix Set Display   ;Other Set Display   o–––––   p–––––   q–––––   – n–––––   n–––––   r––––   – s–––––   t–––––   ––––   u–––––   v–––––   w–––––   x–––––   y–––––   z–––––   ––––   • Settings enclosed in parentheses can be set with the RCU (RCB) switch or VR in RCU (RCB) mode.   • Settings enclosed in [ ] is displayed when the optional card to process video signals (SDI card, etc.) is inserted.   • To return to the initial settings, refer to page 53.   -42-   BTM cut: About one-third of the bottom portion of the   screen is excluded from measurement.   R/L cut: About one-third of both the right and left   portions of the screen are excluded from   measurement.   $ Setting and changing of the setting   items (User Mode)   6Iris, Shutter, Gain Set Display   P Video Level Adjustment [Picture Level: –50 to +50]   Convergence level of AUTO IRIS, AUTO GAINUP, ELC   can be adjusted.   Q Detecting Ratio Adjustment   S Auto Iris Level Fine Adjustment   [Light PEAK/AVG: P50 to A50]   [Auto Iris Adjust: OFF, ON]   The ratio of AUTO IRIS, AUTO GAINUP, ELC detected   peak to average can be adjusted within a range.   OFF: The iris control is invalid when the iris switch on the   RCU (RCB) or on the hybrid control panel is in the   AUTO position.   ON: Fine adjustment of auto iris convergence level can   be made with the iris control when the iris switch   on the RCU (RCB) or on the hybrid control panel is   in the AUTO position.   R Photometric Measurement Method Setting   [Light Area: All, Center, Top cut, BTM cut, R/L cut]   A photometric measurement method can be selected for   AUTO IRIS, AUTO GAINUP, ELC.   All:   All the screen area is measured.   RCU (RCB)   Center: The screen is measured mainly in the center   area, about one-third of both the top and   bottom and one-third of both the right and left   portions of the screen are excluded from   measurement.   Top cut: About one-third of the top portion of the screen   is excluded from measurement.   Iris control   Iris switch   -43-   Menu item setting   • When “Synchro Scan” has been selected as the   electronic shutter mode setting:   T Electronic Shutter Mode Setting   [Shutter Mode: Step, S/Scan, ELC]   Bar noise can be reduced by synchro-scan adjustment   in shooting workstation scenes, for example.   Step: Electronic shutter operates at the speed selected   by the Electronic Shutter Step/Synchro Scan   Setting.   ❈ For luminance setting at each shutter speed and synchro-   scan shutter speed, refer to the table below.   S/Scan (Synchro Scan):   Electronic shutter operates at the speed selected   in Electronic Shutter Step/Synchro Scan Setting.   ELC: Electronic shutter is controlled to automatically   Shutter Speed   OFF   Synchro-scan   — Required luminance ratio   1 2 1/100   100.3 Hz   250.0 Hz   492.2 Hz   984.4 Hz   1.969 kHz   3.938 kHz   7.875 kHz   adjust the luminance.   1/250   4 Note   1/500   8 If Frame 1 is selected in CCD Read Out Mode Setting   (u), Electronic Shutter Mode Setting cannot be added.   1/1000   1/2000   1/4000   1/10000   16   32   64   160   U Electronic Shutter Step/Synchro Scan Setting   [Step/Synchro: OFF, 1/100 to 1/10000 (Step),   60.34 Hz to 15.75kHz (Synchro Scan)]   Notes   • In case of using the RCU (RCB), none of the shutter   speeds — 1/250, 1/2000, 1/4000, and 1/10000 can be   selected.   This setting is possible only when Step or Synchro Scan   is selected in Electronic Shutter Mode Setting.   • When “Step” has been selected as the electronic   shutter mode setting:   • In case of using the hybrid control panel, only OFF,   1/100, or ELC can be selected.   OFF: Electronic shutter is turned off.   1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000:   Electronic shutter operates at one of these   speeds as selected.   • If the lens iris switch is at M (Manual) when operating   the camera alone or when the iris switch on the RCU   (RCB) is at AUTO, ELC may not function. Set the lens   iris switch to A (Auto).   • Flickering may increase at ELC under fluorescent lights.   -44-   V Gain Setting   Notes   [Gain: Auto, 0 dB to 30 dB, N/Eye L, N/Eye H]   • Only 0 dB, 9 dB, or 18 dB, AGC LOW, AGC HIGH can   be selected in case of using the RCU (RCB).   If the lens iris switch is at MANUAL, when operating the   camera alone or when the iris switch on the RCU (RCB,   Hybrid control panel) is at AUTO, AGC may not   function.   Auto:   The light quantity is adjusted   automatically.   0 dB:   0 dB should be selected in normal cases.   1 dB to 30 dB: Use this range if sufficient video output   cannot be obtained even when the lens   iris is opened in shooting dark scenes.   N/Eye L (Night Eye L):   • AGC HIGH when the AGC selection switch on the   hybrid control panel is at AGC.   • 0 dB when the manual gain switch on the hybrid control   panel is at LOW, 9 dB when it is at MID, or 18 dB when   it is at HIGH.   Use this mode if sufficient video output   cannot be obtained even if 30 dB gain up   should be selected.   N/Eye H (Night Eye H):   Manual GAIN switch   AGC switch   Use this setting if it is not possible to   achieve a satisfactory video output even   at the Night Eye L setting.   Hybrid control panel   -45-   Menu item setting   W AGC Maximum Gain Setting   7Color Set Display   [AGC Max Gain: 6dB, 12dB, 18dB, 24dB, N/Eye L,   N/Eye H]   This is used to set the maximum gain up when “Auto” has   X Chroma Level Adjustment [Chroma Level: –3 to +3]   Chroma Level can be decreased or increased to three   levels. The signal output to the optional card cannot be   adjusted.   been selected as the gain setting.   Y White Balance Setting   [White Bal: ATW, AWC A, AWC B, 3200K, 5600K]   ATW: The white balance is automatically adjusted to   the optimum position.   AWC A, AWC B:   Once the white balance is adjusted with the   ITEM/AWC switch on the back of the camera, it   is no longer necessary to set the white balance   again if you simply select AWC A or AWC B,   provided that the camera is used under the same   conditions.   Fine color adjustment can be made after setting   AWC by red/blue gain adjustment in User Mode   or from the RCU (RCB).   3200K: The white balance is adjusted to 3200K   illumination.   5600K: The white balance is adjusted to 5600K   illumination.   Note   Neither 3200K nor 5600K can be set from the RCU   (RCB) or the hybrid control panel.   -46-   Z ATW Speed Setting   [ATW Speed: Slow 2, Slow 1, Mid, Fast 1, Fast 2]   ATW Speed can be set.   R/B gain   control   R/B pedestal   control   [ Black Level Setting [Pedestal: –150 to +150]   The black level (pedestal) of the luminance (Y) signal can   be set. Used in adjusting the black levels of two or more   cameras.   RCU (RCB)   \ Painting Setting   [Painting: R Gain, B Gain, R Pedestal, B Pedestal:   –150 to +150]   R Gain, B Gain:   Fine adjustment of the white balance can be made   after AWC setting when AWC A or AWC B is   selected in White Balance Setting. In case of using   the RCU (RCB), use the R/B gain controls for this   purpose. The set value returns to 0 after AWC   setting in using the camera alone.   R Pedestal, B Pedestal:   Fine adjustment of the black balance can be made   after ABC setting.   In case of using the RCU (RCB), use the R/B   pedestal controls for this purpose. The set value   returns to 0 after ABC setting in using the camera   alone.   -47-   Menu item setting   8G/L, Color Bar Set Display   9Detail Set Display   ] Horizontal Phase Adjustment [H Phase: –206 to +49]   Horizontal phase can be adjusted when a genlock signal   is supplied.   b Detail Level Setting [Detail: OFF, Low, High]   Contour correction quantity can be selected.   Detail settings made using the Horizontal/Vertical Detail   Level High/Low Setting.   ^ Subcarrier Phase Coarse Adjustment   [SC Coarse: 1, 2, 3, 4]   c Horizontal Detail Level High Setting   Coarse adjustment of subcarrier phase can be made   [H Detail Level H: L+1 to 63]   when a genlock signal is supplied.   d Vertical Detail Level High Setting   [V Detail Level H: L+1 to 31]   _ Subcarrier Phase Fine Adjustment   [SC Fine: –511 to +511]   e Horizontal Detail Level Low Setting   [H Detail Level L: 0 to H–1]   Fine adjustment of subcarrier phase can be made when a   genlock signal is supplied.   f Vertical Detail Level Low Setting   [V Detail Level L: 0 to H–1]   Detail level can be set in horizontal (H) and vertical (V)   directions with the Detail Level Setting at High or Low.   Whichever the direction, H or V, the set level at High   must be at least one position higher than that at Low.   ` Color Bar Setup Setting   [Color Bar Set: 0.0 IRE, 7.5 IRE]   The setup level of color bar can be adjusted.   a Color Bar Setup Setting for the optional cards   [Color Bar Set2: 0.0 IRE, 7.5 IRE]   g Detail Band Setting [Detail Band: 1 to 5]   A contour correction band can be set with the Detail   Level Setting at High or Low. The higher setting, the finer   will be the detail.   This menu is displayed when the optional card to process   video signals is inserted.   The setup level of color bar to output to the optional card   can be adjusted.   Set 0.0 IRE when the SDI card is inserted.   -48-   h Noise Suppress Level Setting   l Flesh Noise Suppress Level Setting   [Flesh Noise Sup.: OFF, Low, High]   Flesh noise is suppressed in two steps when the Detail   Level Setting is at High or Low.   [Noise Suppress: 1 to 10]   Screen noise can be reduced with the Detail Level   Setting at High or Low. If the noise suppress level is set   too high, a fine object will be reproduced less sharply.   m Precision Detail Level Setting   [Precision Detail: OFF, Low, High]   This setting is to narrow detail width and suppress detail   glare.   i Level Dependent Level Setting   [Level Dependent: 0% to 25%]   Screen noise due to the detail of dark parts of an object   can be reduced.   If level dependent level is set too high, however, hair, for   example, will be reproduced less sharply.   j Dark Detail Level Setting [Dark Detail: 0 to 5]   The contours of the darker portions of an object can be   emphasized.   This setting is possible only when the Level Dependent   Level Setting is set to 0%.   k Chroma Detail Level Setting [Chroma Detail: 0 to 15]   The contours of high-hue portions of an object can be   emphasized.   -49-   Menu item setting   G G Gain: Increases or decreases the green.   :Color Matrix Set Display   Phase: Varies the hue of the green.   n B_Mg Gain: Increases or decreases the intermediate   G_Cy Gain: Increases or decreases the intermediate   color between blue and magenta.   color between green and cyan.   B_Mg Phase: Varies the hue of the intermediate color   G_Cy Phase: Varies the hue of the intermediate color   between blue and magenta.   between green and cyan.   Mg   Mg   Gain: Increases or decreases the magenta.   Cy   Cy   Gain: Increases or decreases the cyan.   Phase: Varies the hue of the magenta.   Phase: Varies the hue of the cyan.   Mg_R Gain: Increases or decreases the intermediate   Cy_B Gain: Increases or decreases the intermediate   color between magenta and red.   color between cyan and blue.   Mg_R Phase: Varies the hue of the intermediate color   Cy_B Phase: Varies the hue of the intermediate color   between magenta and red.   between cyan and blue.   R R Gain: Increases or decreases the red.   B B Gain: Increases or decreases the intermediate   Phase: Varies the hue of the red.   color between blue and magenta.   R_Yl Gain: Increases or decreases the intermediate   Phase: Varies the hue of the intermediate color   color between red and yellow.   between blue and magenta.   R_Yl Phase: Varies the hue of the intermediate color   between red and yellow.   Yl   Yl   Gain: Increases or decreases the intermediate   color of yellow.   Phase: Varies the hue of the yellow.   Yl_G Gain: Increases or decreases the intermediate   color between yellow and green.   Yl_G Phase: Varies the hue of the intermediate color   between yellow and green.   -50-   v PC Control Access Speed Setting [Baud Rate:   1200bps, 2400bps, 4800bps, 9600bps]   ;Other Set Display   o Gamma Level Setting [Gamma: 0.35 to 0.55]   This setting is to select a communication speed in   controlling the camera from the computer.   Gamma correction level can be set.   p Knee Level Setting   w Component Output Setting   [Knee Point: 88% to 98%, Dynamic]   88% to 98%: The level of video signals subject to knee   (knee point) can be set.   [Component: RGB, Y/Pr/Pb, Y/C]   This enables RGB, Y/Pr/Pb or Y/C to be selected as the   component signals which are to be output from the I/F   REMOTE connector.   Dynamic:   Knee level is automatically adjusted   according to the scene.   x Aspect Ratio Selection [Aspect Ratio: 16:9, 4:3]   q White Clip Level Setting [White Clip: 95% to 110%]   The peak level of video signals to be white-clipped can   be set.   Aspect ratio can be selected from 16:9 or 4:3.   y Fan Setting [Fan SW: OFF, Auto]   OFF: Select this setting to stop the fan when its   operating sound is found to be bothersome in a   studio or other such environment.   Auto: The temperature is detected automatically, and   the fan starts operating when the temperature   exceeds approx. 95°F (35°C).   r Flare Correction Level Setting [Flare R/G/B: 0 to 100]   Flare correction level can be adjusted.   s Black Stretch Setting [Black Stretch: ON, OFF]   Black stretch to correct the suppression of black portions   at low luminance can be set to ON or OFF.   Under normal circumstances, the “Auto” setting is   used.   t Clean DNR Setting [Clean DNR: OFF, Low, High]   This enables the clean DNR effect to be selected.   z Language Selection [Language: English, Japanese]   u CCD Read Out Mode Setting   English:   Menu screen is displayed in English.   [Field/Frame: Field, Frame 1, Frame 2]   Japanese: Menu screen is displayed in Japanese.   Field:   CCD storage will be by field storage.   Frame 1: Vertical resolution increases in frame storage.   Frame 2: Vertical resolution is raised without increasing   residual images by frame storage and   -51-   electronic shutter.   Setting and changing the optional cards   3. Safety Zone Setting [Safety Zone: OFF, 1, 2, 3, 4, 5]   <Optional Card Setting Sub Menu   This is used to select the type of safety zone which is   displayed on the viewfinder. A safety zone is not   displayed when “OFF” is selected.   This sub menu appears when a studio card (AW-PB305 or   AW-PB506) has been inserted into the optional card slot.   ❈ The safety zone and center marker indicate electrical   positions and, as such, they may be at variance with   their optical positions.   1 –––––   2 ––––––   3 –––––   4 –––––   1 4 2 5 3 1. Zebra Indicator Setting [Zebra: OFF, ON]   This is used to select whether to display the zebra pattern   on the viewfinder.   The inside and outside frames denote safety zones of about   90% and about 95%, respectively.   OFF: The zebra pattern is not displayed on the   viewfinder.   ON: The zebra pattern is displayed on the viewfinder.   4. EVF Output Setting [EVF Output: Y, CVBS]   This is used to set the signals to be output to the   viewfinder.   2. Zebra Level Setting [Level: 70% to 110%]   This enables the zebra pattern to be displayed so that it   will provide as a general guideline for the luminance level.   ❈ It can be set when “ON” has been selected as the   zebra indicator setting.   Y:   The luminance signal is output to the viewfinder.   CVBS: The color signals are output to the viewfinder.   ❈ When “CVBS” has been selected as the setting, the   zebra pattern will not be displayed on the viewfinder.   -52-   Setting to initial set   $ Setting to initial set   In case of the wrong setting in any use mode, take the   following steps to return to the initial settings.   (3) If the NO/BAR switch is pressed, or if the YES/ABC   switch is not pressed, within about 10 seconds, the   screen shown at 3, and the camera returns to main   menu, and the existing settings are not initialized.   (1) Select [Initialize Data] on the main menu screen of each   Use Mode. (See page 29.)   Press the YES/ABC switch, then [Initialize Data] screen   shown for about 10 seconds.   Note   (2) Press the YES/ABC switch within about 10 seconds to   return to the initial settings, the existing settings are   initialized, the screen shown at 2, and the camera   returns to main menu.   If you are using an option card, the Option Card Setting   Submenu will not be initialized even if “Return to   Initialize” is performed.   1 2 3 -53-   $ Initial settings of the setting items (Factory preset values)   U Halogen, Fluorescent, Outdoor Mode   Item   Halogen mode Fluorescent mode Outdoor mode   Picture Level   Light PEAK/AVG   Light Area   Auto ND (ELC)   Auto Gain Up   AGC Max Gain   Manu Gain Up   Pedestal   0 0 0 0 0 0 Top cut   OFF   Top cut   OFF   Top cut   ON   Brightness   Set   OFF   OFF   ON   –––   –––   N/Eye H   –––   0dB   0dB   0 0 –40   Chroma Level   Flesh Tone   White Bal   0 0 +0   0 AWC A   –––   +0   0 ATW   Mid   Color Set   AWC A   –––   ATW Speed   H Phase   0 1 0 1 0 1 SC Coarse   G/L, Color   Bar Set   SC Fine   Color Bar Set   Color Bar Set 2   0 0 0 7.5 IRE   0.0 IRE   7.5 IRE   0.0 IRE   7.5 IRE   0.0 IRE   DTL Select   Level   Sharpness   High   OFF   Sharpness   High   OFF   Sharpness   High   OFF   Sharpness   (DTL) Set   Noise Suppress   Clean DNR   OFF   OFF   OFF   Note   Flesh Noise Sup.   OFF   OFF   OFF   When the optional card   is inserted to the   camera, “Language”   menu will not be   returned to default   setting even if “Initialize   Data” menu is executed.   Contrast (Gamma)   Shutter Speed   Synchro Scan   V Resolution   Baud Rate   Mid   OFF   Mid   OFF   Mid   Auto ND   –––   Normal   9600bps   Y/Pr/Pb   16:9   –––   –––   Normal   9600bps   Y/Pr/Pb   16:9   Normal   9600bps   Y/Pr/Pb   16:9   Other Set   Component   Aspect Ratio   Fan SW   Language   Auto   (English)   Auto   (English)   Auto   (English)   -54-   U User Mode   Item   User mode   Item   User mode   Picture Level   Light PEAK/AVG   Light Area   0 0 Detail   High   20   19   13   8 H Detail Level H   V Detail Level H   H Detail Level L   V Detail Level L   Detail Band   Top cut   OFF   Iris,Shutter, Auto Iris Adjust   Gain Set   Shutter Mode   Step/Synchro   Gain   Step Detail Set 1   OFF   0dB   –––   5 Noise Suppress   Level Dependent   Dark Detail   3 0%   0 AGC Max Gain   Chroma Level   White Bal   ATW Speed   Pedestal   Painting R Gain   B Gain   +2   AWC A   Chroma Detail   0 OFF   OFF   ––– Detail Set 2 Flesh Noise Suppress   0 0 0 0 0 Precision Detail   Color Set   R Pedestal   B Pedestal   H Phase   SC Coarse   SC Fine   Color Bar Set   Color Bar Set2   0 1 G/L, Color   Bar Set   0 7.5 IRE   0.0 IRE   -55-   Setting to initial set   Item   User mode   Item   User mode   B_Mg Gain   B_Mg Phase   Mg Gain   Mg Phase   Mg_R Gain   Mg_R Phase   0 0 Gamma   0.45   88%   110%   0 Knee Point   White Clip   Flare R   +27   0 Other Set 1   0 0 Flare G   Flare B   Black Stretch   Clean DNR   0 0 OFF   OFF   R R Gain   +15   0 Phase   R_Yl Gain   R_Yl Phase   Yl Gain   Yl Phase   Yl_G Gain   Yl_G Phase   0 0 Field/Frame   Baud Rate   Component   Aspect Ratio   Fan SW   Field   9600bps   Y/Pr/Pb   16:9   Auto   (English)   +18   +6   0 Other Set 2   Color   Matrix Set   0 Language   G G Gain   Phase   +30   +112   0 G_Cy Gain   G_Cy Phase   Cy Gain   Cy Phase   Cy_B Gain   Cy_B Phase   0 Note   +44   –15   0 When the optional card is inserted to the camera,   “Language” menu will not be returned to default setting   even if “Initialize Data” menu is executed.   0 –20   +36   B B Gain   Phase   -56-   |