Nikon ProStaff Team Realtree 2 7x32 User Manual

Nikon Riflescope  
ProStaff  
Team Realtree  
3-9x50  
3-9x40  
2-7x32  
4x32  
Instruction Manual  
Congratulations on your choice of a Nikon RIFLESCOPE. Your new scope is the  
finest example of Nikon’s rugged and durable construction and precision bright  
optics; important qualities for a serious shooter’s riflescope.  
Whether you use your scope for hunting or for target shooting, the procedure for  
mounting is identical. You should acquire a set of high quality steel mounting  
rings which have a standard diameter of 25.4 mm (1inch). Follow the ring  
manufacturer’s instructions for mounting procedures. After mounting the scope  
on your rifle, follow the procedures for reticle alignment.  
Caution  
(1) Do not look at the sun through the riflescope. It will permanently damage  
your eye. This precaution applies to all optical devices such as cameras and  
binoculars.  
(2) The riflescope is effectively sealed against moisture and dust. You may use  
your scope safely either in the rain or in dusty climates. To preserve the  
appearance of the scope, we suggest that it be dried and cleaned prior to  
storage. Use a soft cloth for cleaning metal surfaces and use photographic lens  
tissue to clean the scope’s lenses.  
When setting the reticle for hunting, you should determine your standard range  
and then adjust the reticle based upon that target distance. For targets which  
vary from the standard distance you may simply adjust the position of the reticle  
in relation to your target, or you may wish to use the procedure for trajectory  
compensation. It’s up to your personal preference.  
We hope that you will enjoy your new Nikon RIFLESCOPE for many years to  
come. Enjoy using it, and above all, always follow safe shooting procedures!  
Tube Diameter  
Objective Outside Diameter  
Length  
(mm)  
(in)  
25.4  
1
25.4  
1
25.4  
1
25.4  
1
(mm)  
(in)  
47.3  
1.86  
58.7  
2.31  
39.3  
1.55  
39.3  
1.55  
(mm)  
(in)  
312  
12.3  
325  
12.8  
248  
11.2  
248  
11.2  
Weight  
(g)  
388  
470  
354  
340  
(oz)  
13.7  
16.6  
12.5  
12.0  
Adjustment Graduation*  
(moa)  
:1 click  
:1 click  
:1 click  
:1 click  
Max Internal*  
Adjustment (moa)  
(Elevation & Windage)  
80  
80  
80  
80  
Parallax Setting  
(at factory)  
(m)  
(yards)  
91.44  
100  
91.44  
100  
68.58  
75  
45.72  
50  
Outside Diameter of  
Eyepiece  
(mm)  
(in)  
39.3  
1.55  
39.3  
1.55  
39.3  
1.55  
39.3  
1.55  
*moa= minute of angle  
** (at minimum magnification)-(at maximum magnification)  
: At 100 yards  
3. Instructions  
(1) Focusing  
:At 75 yards  
:At 50 yards  
Look through the eyepiece with your eye positioned about 10cm (4 in)  
away from the eyepiece lens (Fig. 3-1), and you will see the Nikoplex  
reticle (Fig. 3-2), or the BDC reticle (Fig. 3-3).  
Be sure your eye is positioned within proper alignment and proper eye  
relief otherwise the view will “black out.”  
Point the objective end of the scope at the sky (Do not point at the sun) or  
at a plain unpatterned wall.  
Loosen the lock ring.  
Turn the eyepiece adjustment counter-clockwise and then turn it  
clockwise until the reticle appears sharp.  
Finally, without moving the eyepiece adjustment, turn the eyepiece lock  
ring as Fig. 3-4 to end so that the eyepiece adjustment will be firmly  
locked.  
The lock ring must be firmly tightened to ensure an air-tight seal.  
(2) Magnification  
The riflescope 4x32 has a fixed magnification of 4X.  
The riflescope 3-9x40, 3-9x50 has a variable magnification from 3 to 9X,  
2-7x32 from 2 to 7X.  
To change powers, just rotate the power selector ring until the desired  
magnification appears adjacent to the power index dot.  
(3) Adjustment of the riflescope  
Sighting through the riflescope, align the rifle with your aiming point on the  
target and shoot a trial round. If the bullet does not hit the aiming point, adjust  
the elevation and windage, as follows:  
If the bullet hits under the aiming point, turn the elevation adjustment  
(counter-clockwise) in the direction of the arrow marked “U” for up as in  
Fig. 3-5. If the bullet hits high, turn adjustment (clockwise) in the direction  
of the arrow marked “D” for down.  
If the bullet hits to the right of the aiming point, turn the windage  
adjustment (clockwise) in the direction of the arrow marked “L” for left as  
in Fig. 3-6. If the bullet hits to the left of the aiming point, turn adjustment  
(counter-clockwise) in the direction of the arrow marked “R” for right.  
After the reticle has been adjusted to the point of impact, insert the tip of  
a screwdriver into the slot of the scale ring and rotate the scale ring so  
that the “ ” is lined up with the index dot. (Fig. 3-7, Fig. 3-8)  
1) Lock Ring  
2) Eyepiece Adjustment  
3) Eye Relief  
Note:  
The windage and elevation scales of the riflescope 3-9x40, 3-9x50, 2-  
7x32, and 4x32 are calibrated in division of minute of angle with a click  
at intervals of minute if angle (one division).  
When adjusting the reticle to the point of aim, remember that one minute  
of angle equals approximately one inch (2.54 cm) at 100 yards (91.44 m).  
Therefore, if the impact point is two inches (5.08 cm) low and one inch  
(2.54 cm) right at 100 yards (91.44 cm) Parallax Setting, you should adjust  
two minutes of angle up one minute of angle left. In case of 50 yds (45.72  
m). Parallax Setting the adjusting value is double. In case of 75 yds (68.58  
m) Parallax Setting is 1.5 times.  
Maintenance  
(1) Lens cleaning  
To remove dirt or fingerprint, soak gauze or lens cleaning paper (silicon-free  
paper sold at camera shop) with a small quantity of absolute alcohol (available  
form drugstore) and lightly wipe off. Wiping with leather chamois is not  
recommended as it is likely to damage the lens surface.  
Dust may scratch the lens surface or corrode the lens.  
Brush dust off using a soft oil-free brush.  
(2) Scope Exterior  
Use a soft dry cloth to wipe off any dirt or fingerprints that might accumulate.  
It is not necessary to oil the scope’s surface.  
(3) Windage/Elevation Adjustments  
These adjustments are permanently lubricated. Do not attempt to lubricate  
them. Cover with caps supplied, except when adjusting, to keep out dust and  
dirt.  
(4) Eyepiece Adjustment  
This adjustment is permanently lubricated. Do not attempt to lubricate.  
(5) Power Selector Ring  
No lubrication is required on the power selector ring.  
Do not loosen or remove screws in power selector ring.  
In the event you should require service for your Nikon RIFLESCOPE, in case of  
USA market, please send it directly to:Nikon Scope Service  
841 Apollo Street, Suite 100  
El Segundo, CA. 90245-4721  
1-800-Nikon SV.  
In other market, please bring it to dealer from which you purchased it.  
Manufacturer: Nikon Inc.  
1300 Walt Whitman Road  
Melville, NY 11747-3064  
P: (631)547-8632  
F: (631)547-4040  

Pioneer Super Tuner III D+ AVH P7950DVD User Manual
Panasonic Lumix Mirrorless Camera DMCGF3XT User Manual
Panasonic KX TCM943 B User Manual
Panasonic AJ HPX3000 User Manual
NEC MultiSync LCD1735NXM User Manual
Mace CAM 16X User Manual
KitchenAid Blender KHB1231 User Manual
Kenmore 4EW150 User Manual
JVC KD SH77 User Manual
JVC GZ MS120BU User Manual