Jacuzzi OPTICATM 300 User Manual

OPTICA300  
SHOWER MIXER/TRANSFER VALVE  
INSTALLATION INSTRUCTIONS  
FINISHING WALL  
TILE (FINISH SURFACE)  
SEALANT (SILICONE) ON BACKSIDE OF  
FACEPLATE  
FACEPLATE (SEALANT NOT PROVIDED)  
2-3/8" DIA.  
GASKET  
TRIM SLEEVE OF TRANSFER VALVE  
REAR VIEW  
4-15/16" MINIMUM  
LEFT-HAND THREAD TO  
SWEAT ADAPTOR (NOT PROVIDED)  
COPPER PIPE (NOT PROVIDED)  
FEMALE THREAD TO SWEAT ADAPTOR  
(NOT PROVIDED)  
SEALANT (100% SILICONE) ON BACKSIDE OF  
FACEPLATE (SEALANT NOT PROVIDED)  
NOTE: WHEN INSTALLING BAND, RING, ROPE  
OR FACETED HANDLE, PULL TRIM SLEEVE OUT  
TO MEET HANDLE.  
GASKET  
2-3/8" DIA.  
TRIM SLEEVE  
PLASTER GUARD  
REAR VIEW  
(FRONT HAS RED  
AND BLUE DOTS)  
WOOD CROSS MEMBER  
OPTICA 300  
WARNING: This system/device must be set by the installer to ensure safe, maximum temperature. Any change in  
the setting may raise the discharge temperature above the limit considered safe and may lead to scalds.  
CAUTION: As the installer of this valve, it is your responsibility to properly install and adjust this valve per the  
instructions given. This valve does not automatically adjust for inlet temperature changes, therefore, it is necessary  
to adjust the Rotational Limit Stop at the time of installation. You must inform the owner/user of this requirement by  
following the instructions below. After installation and adjustment, you must write in the temperature and the date  
you adjusted the Rotational Limit Stop on the warning label provided and apply or attach it to the hot water heater.  
Be sure this instruction sheet is delivered to the owner/user.  
WARNING: This pressure balanced bath valve is designed to minimize the effects of outlet water temperature  
changes due to inlet pressure changes, commonly caused by dishwashers, washing machines, toilets and the like.  
It may not provide protection from scalding when there is a failure of other temperature controlling devices elsewhere  
in the plumbing system if the Rotational Limit Stop is not properly set, or if the hot water temperature is changed after  
the Rotational Limit Stop is set, or if the water inlet temperature changes due to seasonal changes.  
INSTALLER: LEAVE THIS INSTRUCTION MANUAL FOR OWNER'S/USER'S REFERENCE  
©1995 Jacuzzi Whirlpool Bath G570000 D 12/06  
Page 1  
8. Slide bonnet nut (1) over the cartridge and thread  
onto the body. Hand tighten securely.  
WARNING:Insomeinstances,settingtheRotational  
Limit Stop in the hottest position (full counterclock-  
wise) could result in scald injury. It is necessary to  
adjust the Rotational Limit Stop so that the water  
coming out of the valve will not scald the user when  
the handle of the valve is rotated to the hot side.  
Adjustrotationallimitstop. Afterwaterhasrunasufcient  
length of time so that cold water is as cold as it will get,  
and hot water is as hot as it will get, place handle back  
on stem and rotate handle counter clockwise to the hot-  
test position. Place a thermometer in a plastic tumbler,  
and hold the tumbler in the water stream. Record the  
temperature reading and note or mark the position of  
the Rotational Limit Stop on the mating part. If the water  
temperature is above 120°F the Rotational Limit Stop  
must be rotated clockwise to reduce the temperature  
(See illustration).  
1
9. Flush your system prior to installing the shower  
head. Place handle on valve stem and turn handle to  
full mix position. Turn ON water supplies, check for  
leaks and let lines ush for one minute without moving  
faucet handle. Divert water to shower head and ush  
for 30 seconds. This will remove any debris from lines  
which can damage internal parts of the faucet and  
create leaks. After ushing, shut OFF water at faucet.  
Remove handle and attach escutcheon. Attach shower  
head.  
RemovetheRotationalLimitStopandreplaceitonetooth  
counterclockwiseforevery6°F(approximate)reduction  
in temperature that must be made. If water temperature  
isbelow90°F,rotatethestopcounter-clockwise. Repeat  
asnecessary. Makesurecoldwaterowsfromthevalve  
rst and does not exceed 120°F at the hottest ow. A  
guide to setting the approximate outlet temperature is  
included. This is only a guide and any setting must be  
veried by using the above procedure.  
CAUTION: Connection of deck-mount spouts to in-  
wall valves is not recommended. Neither is the use of  
handshowersconnectedtobathspoutsinabath/shower  
push button diverter combination.  
Hotter  
Colder  
Disc  
Stem  
1st Position  
Rotational Limit Stop  
10. IMPORTANT: The Rotational Limit Stop is used to  
limit the amount of hot water available such that, if set  
properly, the user will not be scalded if the handle ac-  
cidentally is rotated all the way to “hot” when a person  
is showering or lling a tub. The rst position allows the  
LEAST amount of hot water to mix with the cold water  
in the system. In the rst position the water will be the  
coldest possible when the handle is turned all the way to  
hot.AsyoumovetheRotationalLimitStopcounterclock-  
wise, you progressively add more and more hot water  
in the mix. The last position to the left will result in the  
greatest amount of hot water to the mix, and the great-  
est risk of scald injury if someone accidentally turns the  
valve handle all the way to the hot side while showering  
or lling a tub.  
©1995 Jacuzzi Whirlpool Bath G570000 D 12/06  
Page 3  
HELPFUL HINTS:  
1. Before removing cartridge assembly for any maintenance, be sure to note the position of the stop on the cap.  
The cartridge assembly must always be put back in the same position. For normal installations, the stop on the cap  
will face the left. To be safe, after you have nished the installation turn ON valve to make sure cold water ow  
rst.  
2. To remove cartridge from body, shut OFF water supplies and remove handle, trim sleeve and bonnet. Place  
handle on stem and rotate clockwise while lifting cartridge out of body.  
3. To remove seats and springs, remove cartridge (see above). Separate cap assembly from the housing assem-  
bly by rotating the cap counter clockwise 90 degrees. Separate cap and housing assemblies. Remove seats and  
springs. Place new seats and spring. Place the largest diameter of the spring into the seat pocket rst and then  
press the tapered end of the seal over the spring. Reassemble cartridge and replace in body following instructions  
given in Step 1 above.  
4. If the water in your area has lime, rust, sand or other contaminants in it, your pressure balanced valve will require  
periodic inspection. The frequency of the inspection will depend on the amount of contaminants in the water. To  
inspect cartridge, remove it and follow Step 1. Turn the valve to the full mix position and shake the cartridge rigor-  
ously. If there is a rattling sound, the unit is functional and can be reinstalled following instructions given in Step 1  
as listed. If there is no rattle, replace housing assembly.  
No adjustment to the Optica shower mixer Rotational Limit Stop should be made except by a trained installer.  
CARE INSTRUCTIONS  
Your Optica Faucet is designed and engineered in accordance with the highest quality and performance standards.  
With proper care, it will give you years of trouble free service. Care should be given to the cleaning of this product.  
Although its nish is extremely durable, it can be damaged by harsh abrasives or polish. To clean, wipe gently with  
a damp cloth and blot dry with a soft towel.  
TROUBLESHOOTING  
CONDITION  
REMEDY  
Replace seats and springs – Repair Kit RP4993.  
Check conditions of lower o-rings and replace if  
necessary.  
Faucet leaks from bath spout/showerhead – SHUT  
OFF WATER SUPPLIES  
If leak persists – SHUT OFF WATER SUPPLIES  
Unable to maintain constant water temperature  
Replace housing assembly (PN D513000) – Re-  
pair Kit RP19805  
Replace housing assembly with RP19805 or follow  
Helpful Hint #4.  
If your Optica 300 components do not match this unit, please contact Service Support: 1-800-288-4002  
Page 4  
©1995 Jacuzzi Whirlpool Bath G570000 D 12/06  
WARNING: This is a guide to help you set the Rotational Limit Stop. This is only a guide and should be veried by  
following the instructions on setting the rotational limit stop given in this installation and instruction sheet.  
MIX TEMPERATURE-VS-POSITION OF ROTATIONAL LIMIT STOP  
APPROXIMATE MIX TEMPERATURE (°F) WITH VARYING INLET TEMPERATURES  
Cold Hot  
Cold Hot  
Cold Hot  
Cold Hot  
Cold Hot  
Cold Hot  
Cold Hot  
Cold Hot  
Setting of limiter  
50°F 160°F  
50°F 120°F 70°F 120°F 50°F 140°F  
70°F 140°F  
85°F 180°F  
40°F 180°F  
70°F 160°F  
SHUT OFF ZONE: NO FLOW APPROXIMATELY 0-20 DEGREES OF HANDLE ROTATION  
1st Position  
2nd Position  
3rd Position  
4th Position  
50  
61  
68  
70  
79  
83  
50  
67  
75  
70  
83  
90  
70  
74  
84  
70  
89  
97  
40  
70  
84  
85  
101  
110  
5th Position  
6th Position  
7th Position  
74  
79  
82  
85  
87  
90  
93  
95  
85  
96  
91  
104  
110  
115  
118  
95  
117  
125  
130  
135  
91  
101  
104  
107  
99  
103  
109  
115  
97  
104  
108  
8th Position  
104  
(Factory Set)  
9th Position  
10th Position  
11th Position  
89  
100  
105  
115  
117  
134  
138  
111  
121  
133  
115  
128  
149  
124  
136  
151  
124  
140  
165  
141  
153  
172  
98  
111  
Setting of limiter  
The rst position of the Rotational Limit Stop (the Limiter) is that position that restricts the rotation of the stem the  
most and is at the maximum counterclockwise setting. According to industry standards, the maximum allowable  
temperature of the water exiting from the valve is 120°F. This temperature may vary in your local area. The Rota-  
tional Limit Stop may need to be readjusted if the inlet water temperature changes. For instance, during the winter,  
the cold water temperature is colder than it is during the summer which could result in varying outlet temperatures.  
Typical temperature for a comfortable bath or shower is between 90°-110°F.  
©1995 Jacuzzi Whirlpool Bath G570000 D 12/06  
Page 5  
This page left blank.  
CAUTION  
Sinceplumbingttingsmaycontributedetectableamountsofleadtowater,thefollowingnoticeisrequiredbyCalifor-  
nialaw(Proposition65). "ThisproductcontainsachemicalknowntotheStateofCaliforniatocausebirthdefectsor  
reproductiveharm." Innormaluse,anyleadexposurecanbeminimizedbyallowingthewatertorunfreeforseveral  
secondsbeforedrinking.  
Proper Installation of the ll spout and compliance with local codes is the responsibility of the installer. Jacuzzi  
Whirlpool Bath does not warrant connections of water supply ttings and piping, ll systems, or drain/overow sys-  
tems. Nor is it responsible for damage to the bath (or spa) which occurs during any installation procedure.  
Jacuzzi Whirlpool Bath  
14801 Quorum Dr., Suite 400, Dallas, TX 75254  
Service Support: Call 1-800-288-4002  
©1995 Jacuzzi Whirlpool Bath G570000 D 12/06  
Printed in the U.S.A.  
Printed on Recycled Paper  

Archos Jukebox Traveler Case AV300 User Manual
Audiovox HRDV700 User Manual
Black Decker BLC18750DMS User Manual
Briggs Stratton POWER BUILT 150000 User Manual
Canon Prima Super 150U DATE User Manual
Canon UC 900 User Manual
Canon ZR500 User Manual
Casio FX 9750GII User Manual
Cuisinart ICE 40 User Manual
Fostex FT7RP User Manual