rangeguide
Commercial & Industrial Boilers
& Radiators
www.idealcommercialboilers.com
Ideal Boilers
Ideal Boilers is one of the most respected names in the UK Commercial and
Domestic heating industry. We design and develop ranges to suit the ever
changing UK marketplace. With the market’s continued move towards
condensing products, Ideal launched the
condensing range.
The recent addition of the x tra maintains Ideal’s position as the
market leading supplier in the Commercial and Industrial boiler sector.
The Commercial Heating Team
As industry leaders Ideal Boilers and Stelrad Radiators are committed to
ensuring that all products are engineered to the highest standards.
To support our products we have a comprehensive service department who
can supply you with in-depth product knowledge and system advice which
will ensure that your heating will run efficiently and will increase the
lifespan of our products.
Contact Numbers
Sales
Tel: 01482 498690
Fax: 01482 498621
Technical
Tel: 01482 498376
Fax: 01482 498621
Training
Tel: 01482 498432
Fax: 01482 498605
email: commercial_heating@idealboilers.com
Website
Our newly designed website contains useful information including details of
training courses, product information and literature, merchant stockists,
a background to Part L2, contact information and many more features.
You will find the website located at:
www.idealcommercialboilers.com
3
condensing
icos HE 30 + 36kW
• Wall mounted
• Robust cast aluminium heat exchanger
• Compact
• Easy to install and service
• Modulating output down to 10.4kW
• Wide range of flue options
• Optional remotely mountable user controls
General Data icos HE (30 + 36)
Model
30
36
Boiler Output (condensing) 50/30˚C
11.4 - 32.8
10.4 - 30.1
11.4 - 39.8
10.4 - 37.0
Boiler Output (non-condensing) 80/60˚C
Height
645
450
410
28
Width
Depth
Flow/Return Connections (mm)
Gas Inlet (BSP)
RC1/2
”
Concentric
Flue Size (mm)
60/100
80/80
60/100
80/80
Twin Pipe
Maximum Working Pressure (bar)
Water Content (L)
3
4.7
4.7
Approx Dry Weight (kg)
52.6
52.6
Top (mm)
Below (mm)
Left (mm)
Right (mm)
Front (mm)
165
150
15
Boiler
Clearances
15
450
Condensate Drain (mm)
21.5
Option Kits
Boiler
icos HE 30 + 36
Remote user control kit
Stand off kit
✓
✓
Syphon kit
Condensate pump kit
✓
✓
4
W 45 - 80kW
• Natural gas and propane
• Single unit or modular configuration,
wall or frame mounted
• Robust cast aluminium heat exchanger
• Easy to install and service
• Simple UK voltage system controls wiring
• Modulating output down to 13kW
• Wide range of flue options
General Data
Model
W (45 - 80)
W45
W45P
W60
W60P
W80
W80P
Boiler output (condensing)
50/30˚C
13.9 - 46.9
13.7 - 45.9
13.9 - 62.3
13.6 - 60.6
21.3 - 82.7
20.7 - 80.0
Boiler output (non-condensing)
80/60˚C
12.6 - 43.7
12.6 - 58.9
19.5 - 78.2
Height
900
Width
540
540
540
540
650
650
Depth
500
R11/4
22
Flow/Return Connections (BSP)
Gas Inlet (mm)
Flue Size (mm)
80/125 & 100/150
80/125 & 100/150
4
100/150
Maximum Working Pressure (bar)
Water Content (L)
Approx Dry Weight (kg)
8
8
8
8
10
10
87
87
88
88
101
101
Top (mm)
Below (mm)
Left (mm)
Right (mm)
dependant on flue
300
50
Boiler
Clearances
50
Option Kits
Remote indication kit
Hours run meter(s)
BMS (0-10V) kit
✓
Boiler
W
Modulating sequencer kit
Programmable room thermostat kit
Control interface kit
Outside sensor kit
Tank sensor kit
✓
✓
✓
✓
✓
*
✓
Pump kit
✓
✓
Multi boiler frame and header kits
*Provided as standard
5
condensing
p lu s II 90 - 310kW
Range of six models
•
•
•
•
•
•
•
•
•
Compact size - small footprint
High modulation - Close load matching (all models down to 11.6kW)
108.4% Net efficiency (fully condensing) at 30% part load
Boilers consist of several modules giving built-in standby capability
Robust cast aluminium heat exchanger
New
Model
Integral commissioning and fault diagnostics
Optional flue and system connections for fast installations
Meets Building Regulations 2006 (Part L2)
General Data
Model
p lu s II (90 - 310)
F90
F140
F180
F220
F270
F310
Boiler output (condensing)
50/30˚C
12.5 - 92.6
12.5 - 136.8
11.2 - 132.2
12.5 - 179.3
12.5 - 228.6
12.5 - 280.7
12.5 - 321.5
Boiler output (non-condensing)
80/60˚C
11.2 - 89.5
11.2 - 173.4
11.2 - 221.0
11.2 - 271.3
11.2 - 311.0
Height
1053
Width
695
695
832
968
1102
1236
Depth
695
R2
Flow/Return Connections (BSP)
Gas Inlet (BSP)
Flue Size (mm)
R11/2
150
150
150
200
200
200
Maximum Working Pressure (bar)
Water Content (L)
Approx Dry Weight (kg)
6
10.1
153
14.2
182
18.3
223
22.4
261
26.5
301
30.6
345
Front (mm)
600
Boiler
Clearances
Back (mm)
Side (mm)
450*
450*
450
450
450
450
50 (1 side) & 450 (other side), increase to 600 for side flues.
*F90 & F140 300 if no rear flue.
Option Kits
Boiler
p lu s II
Hours run meter(s)
BMS (0-10V) kit
Outside sensor kit
Tank sensor kit
Remote indication kit
*
*
*
✓
*Provided as standard
6
*
x tra 80 - 560kW
Robust cast aluminium heat exchanger
•
•
•
•
•
•
•
•
•
In-built commissioning and fault diagnostics
Low NOx emissions
Volt free contacts supplied as standard
Meets Building Regulations 2006 (Part L2)
Compact size - small footprint
Extended
Output
Range
Fully modulating operation down to 20% of output
Up to 107.5% nett efficiency (fully condensing)
Fits through standard doorways
General Data
Model
x tra (80 - 560)
80
120
160
200
240
280
320
400
480
560
Boiler output (condensing)
50/30˚C
25.6 -
82.2
25.6 -
123.4
32.0 -
164.5
47.1 -
207.8
51.4 -
249.4
55.6 -
290.9
75.3 - 107.5 - 116.1 - 118.3 -
329.0
415.6
498.8
581.8
Boiler output (non-condensing)
80/60˚C
23.3 -
77.4
23.2 -
116.0
29.0 -
154.8
43.1 -
195.4
47.0 -
234.5
51.0 -
273.6
67.8 -
311.6
97.7 - 105.5 - 107.7 -
390.8
469.0
547.2
Height
1150
600
1327
R2”
R2”
R1”
200
6
Width
600
1024
R2”
R2”
R1”
150
600
1024
R2”
R2”
R1”
150
600
1024
R2”
R2”
R1”
150
600
1327
R2”
R2”
R1”
200
600
1327
R2”
R2”
R1”
200
1200
1004
80*
1200
1326
80*
1200
1326
80*
1200
1326
80*
Depth
Flow connection (BSP)
Return connection (BSP)
Gas inlet connection (BSP)
Nominal flue size / concentric (mm)
Maximum working pressure (bar)
Water content (L)
Weight (kg)
80*
80*
80*
80*
R2*
200
R2*
250
R2*
250
R2*
250
11.0
132
14.3
150
17.5
168
18.4
198
24.0
215
600
700
27.2
233
35.0
336
36.8
396
48.0
430
54.4
466
Front (mm)
Back (mm)
Boiler
Clearances
700
700
700
700
700
1000
450
1000
450
1000
450
1000
450
Side (mm) 450 150 450 150 450 150 450 150 450 150 450 150
(LH)(RH) (LH)(RH) (LH)(RH) (LH)(RH) (LH)(RH) (LH)(RH)
*DN flange. Flow, return and gas connection sizes shown are for the optional header kit.
If header kit not used: Flow & Return connections are 2 x R2. Gas connection is 2 x R1.
Option Kits
Boiler
x tra
320 - 560
Boiler
x tra
80 - 280
80 - 280
320 - 560
Modulating sequence control for
controlling multiple boiler installations
Programmable room thermostat
Tank sensor kit
✓
✓
Outside sensor kit
✓
✓
✓
✓
✓
Room sensor kit
✓
✓
✓
✓
✓
✓
n/a
Sequencer DHW sensor kit
Control interface kit
Standard
7
BMS control kit (0-10V)
Standard
condensing
Concord CXC 48 - 116kW
• Natural gas fired condensing boiler
• Meets Building Regulations 2006 (Part L2)
• Fully condensing high efficiency 85%
at 80˚C, 93% at 60˚C flow
• Compact space saving design
• Full automatic ignition
• Advanced electronic controls
General Data Concord CXC (48 - 116)
Model
48
70
94
116
Boiler output (condensing)
50/30˚C
48.83
69.84
93.65
116.25
Boiler output (non-condensing)
80/60˚C
44.63
63.84
83.60
106.30
Height
1438
600
Width
Depth
723
846
969
1092
RC1
Flow/Return Connections (BSP)
Gas Inlet (BSP)
Flue Size (mm)
RC2
RC3/4
RC3/4
RC3/4
150
4.5
Maximum Working Pressure (bar)
Water Content (L)
Approx Dry Weight (kg)
28
36
43
51
298
350
442
494
Front (mm)
Boiler
750
200
Clearances
Back (mm)
Side (mm)
50
50
50
100
Option Kits
Boiler
Concord CXC
Remote indication board
Outside sensor
✓
✓
8
GT Condenser 199 - 1096kW
• Up to 16% extra heat
• Compact space saving design
• Adjustable flue and system connections
• Low flue and system resistances
• High insulation levels
• Fanned or standard versions
• Suitable for Harrier, Viceroy and Viscount boilers
General Data GT Condenser (199 - 1096)
Model
RCI 300 RCI 300V
RCI 400 RCI 400V
RCI 500 RCI 500V
Output (kW)
180 - 450
1687
610
230 - 670
1777
698
390 - 986
1883
830
Height (mm)
Width (mm)
Depth (mm) (over optional fan)
Flue Size (mm)
1156
300
1250
350
1376
400
The addition of a GT Condenser to the boiler can
provide up to 16% more heat by cooling the flue gases
to gain both sensible and latent heat from condensation.
The lower the system return temperature being fed into
the Condenser the more the gain. It all provides benefits
in lower emissions and lower fuel bills.
Harrier, Viceroy and Viscount boilers with a boiler output
range suitability from 180kW (614,000 Btu/h) to
986kW (3,364,000Btu/h). Three output models cover
this range and to ensure easy flue installation, each is
available with or without a fan to overcome the flue
pressure loss of the GT Condenser if necessary. A 6 bar
working pressure capability ensures system application
is straight forward.
This GT Condenser range is suitable for gas fired
boilers only but can be fitted to dual fuel boilers with
suitable flue design. Six models are available to suit
Option Kits
Boiler
GT Condenser
RCI 300V
RCI 400V
RCI 500V
Fan version
9
gas atmospheric
Concord CXA/H S/H 40 - 120kW
• Ultra reliable gas atmospheric boilers
• High, full and part load efficiencies -
meets Building Regulations 2006 (Part L2)
• Auto ignition
• Remote indication kit options
• CXA/H natural gas or propane CXA P/H (40-100kW)
• CXA/H is On/Off and CXS/H is High/Low operation
General Data Concord CXA/H S/H (40 - 120)
Model
40/H
50/H
60/H
70/H
80/H
5
90/H
6
100/H
6
110/H
7
120/H
7
Sections
Output (kW)
Height
3
4
4
5
40
50
60
70
80
90
100
110
120
1000
600
1042
RC2
RC3/4
200
6
Width
Depth
750
882
882
1042
1212
1212
1385
1385
Flow/Return Connections (BSP)
Gas Inlet (BSP)
RC3/4
RC3/4
150
RC3/4
175
RC3/4
175
RC1
200
RC1
200
RC1
250
RC1
250
Flue Size (mm)
150
Maximum Working Pressure (bar)
Water Content (L)
22
30
30
37
37
45
45
53
53
Approx Dry Weight (kg)
210
265
265
330
330
750
150
50
395
395
490
490
Front (mm)
Boiler
Clearances
Back (mm)
0
0
0
150
50
300
100
300
100
300
100
300
100
Sides (mm) 50
50
50
Option Kits
Boiler
CXA/H
CXS/H
Volt free contacts, boiler run,
overheat & lockout
✓
✓
✓
✓
✓
✓
✓
Down draft thermostat kit
Header kits (available from merchants)
Propane models
10
Concord Modular 80 - 720kW
• Suitable for Concord CXA/H and CXS/H models
• Multiple installation outputs from 80-720kW
• All servicing and maintenance from the front of boilers
• Large clean-out cover for full access to flueways
• Standard boiler width: 600mm
• Factory assembled and tested units
• Sequencer control kit available
• Remote indication kit options
General Data Concord Modular (80 - 720)
Model
40/H
50/H
60/H
70/H
80/H
90/H
100/H
200kW
300kW
400kW
500kW
600kW
110/H
220kW
330kW
440kW
550kW
660kW
120/H
240kW
360kW
480kW
600kW
720kW
No. Boilers 2x
80kW
100kW
150kW
200kW
250kW
300kW
120kW
180kW
240kW
300kW
360kW
140kW
210kW
280kW
350kW
420kW
160kW
240kW
320kW
400kW
480kW
180kW
270kW
360kW
450kW
540kW
3x
4x
5x
6x
120kW
160kW
200kW
240kW
Option Kits
Boiler
Modular
✓
Sequencer control kit
Outside sensor kit
Mandatory
Sequencer control kit
11
gas atmospheric
Concord CXSi/H 110 - 180kW
• Ultra reliable gas atmospheric boilers
• High, full and part load efficiencies -
meets Building Regulations 2006 (Part L2)
• Auto ignition
• Remote indication kit options
• High/Low operation
General Data Concord CXSi/H (110 - 180)
Model
110/H
120/H
140/H
160/H
9
180/H
10
Sections
7
7
8
Output (kW)
110
120
140
160
180
Height
1000
Width
1107
1036
1107
1036
1230
1353
1086
1476
1140
Depth
1036
Flow/Return Connections (mm)
Gas Inlet (BSP)
Flue Size (mm)
Maximum Working Pressure (bar)
Water Content (L)
Approx Dry Weight (kg)
Flow: DN65 Flange. Return RC2
RC11/2
250
6
250
250
250
300
53
53
60
68
76
520
520
587
700
200
654
721
Front (mm)
Boiler
Clearances
Back (mm)
Side (mm)
100 (not including clearance for side fitted flow header)
Option Kits
Boiler
CXSi/H
Volt free contacts, alarm & boiler run conditions
✓
12
Concord ES/H 140 - 380kW
• High/Low adjustable operation on all models
• High, full and part load efficiencies -
meets Building Regulations 2006 (Part L2)
• Assembled or unassembled
heat exchanger availability
• Robust cast iron heat exchanger
• Easy to install and service
• Low return temperature capability
General Data Concord ES/H (140 - 380)
Model
140/H
160/H
180/H
200/H
11
220/H
12
260/H
14
300/H
16
340/H
18
380/H
20
Sections
Output (kW)
Height
8
9
10
140
160
180
200
220
1406
1322
1362
R2
260
300
340
380
1406
970
1406
1058
1362
1406
1146
1362
1406
1234
1362
1406
1498
1412
1406
1674
1412
1406
1850
1412
1406
2026
1462
Width
Depth
1362
Flow/Return Connections (BSP)
Gas Inlet (BSP)
RP1
250
RP1
250
RP1
300
RP1
300
RP1
300
6
RP11/4
350
RP11/4
350
RP11/4
350
RP11/2
400
Flue Size (mm)
Maximum Working Pressure (bar)
Water Content (L)
61
68
76
84
91
106
122
137
154
Approx Dry Weight (kg)
667
730
807
880
934
1000
500
400
200
1096
1227
1364
1476
Front (mm)
Back (measured from rear edge of jacket) (mm)
At sides Water connection side (RH or LH) (mm)
At sides Non connection side (RH or LH) (mm)
Boiler
Clearances
Option Kits
Boiler
ES/H
Hours run meter (1 or 2 hours)
Flue gas thermometer
✓
✓
13
high efficiency
Super Series 4 50 - 600kW
• Vertical and horizontal models
• High efficiency 85% (gross)
• Low NOx emissions (class 5)
• 50kW Modules
• Sequence controlled
• Compact size
• Complete package gas/water headers
General Data Super Series 4 (50 - 600)
Model
50/V 100/V 150/V 150/VA 200/V 250/V 250/H 300/V 300/H 350/V 400/V 450/V 450/H 500/V 500/H 550/V 550/H 600V 600H
Modules
Output (kW)
Height
1
2
3
3
4
5
5
6
6
7
8
9
9
10
10
11
11
12
12
50
100
150
150
200
250
250
300
300
350
400
450
450
500
500
550
550
600
600
782
439
698
1432 1912 1487 1487 1967 1443 1972 1443 1618 1618 2144 1345 2144 1345 2144 1345 2144 1345
Width
701
698
50
701
698
65
1171 1171 1171 1783 1171 1783 1822 1822 1833 2393 1833 2393 1833 2392 1833 2393
Depth
698
65
698
65
698
80
698
80
698
80
698
80
1350 1350 1350 1350 1350 1350 1350 1350 1350 1350
Flow/Return Connections (DN flange) 40
100
RC2
350
6
100
RC2
350
125
RC2
400
125
RC2
400
125
RC2
400
125
RC2
400
125
RC2
450
125
RC2
450
125
RC2
450
125
RC2
450
Gas Inlet (BSP)
Flue Size (mm)
RC3/4
RC1 RC11
/
4
RC11
200
/
4
RC11
250
/4
RC11
250
/
2
RC11
250
/
2
RC11
300
/
2
RC11
300
/2
125
175
200
Maximum Working Pressure (bar)
Water Content (L)
4.5
11.9
20.7
21.7
26.2
37.7
39.7
44.5
44.5
63.3
68.1
813
97.6
985
92.6 102.4 97.4 107.2 102.2 112
107
Approx Dry Weight (kg)
Front (mm)
82.1 187.7 274.1 296.4 348
461 411.2 511.2 513.7 765
972
1033 1020 1080 1067 1129 1115
950
Back (mm) 25
Left (mm) 450
Right (mm) 450
25
25
25
25
25
25
25
25
950
950
950
950
950
950
950
950
950
950
Boiler
Clearances
900
900
900
900
900
900
900
900
900
900
900
900
900
900
900
900
1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
Option Kits
Boiler
Super Series 4
Water flow switch for boiler protection in
the event of pump failure
✓
✓
✓
External sequencer control kit
Module blanking off pack
14
Super Plus 200 - 600kW
• Horizontal assembly
• High efficiency 85% (gross)
• Low NOx emissions (class 5)
• 100kW Modules
• Ultra compact
• Sequence controlled
• Easy to install and service
General Data Super Plus (200 - 600)
Model
200/S
300/3
3
300/3A
3
400/4
4
400/4A
4
500/5
5
600/6
6
Modules
2
Output (kW)
200
1800
910
990
65
300
1900
1510
990
125
RC2
350
300
400
1900
1510
990
125
RC2
450
6
400
500
1900
2115
990
125
RC2
450
600
1900
2115
990
125
RC2
450
Height
1900
2115
990
1900
2115
990
Width
Depth
Flow/Return Connections (DN flange)
Gas Inlet (BSP)
Flue Size (mm)
Maximum Working Pressure (bar)
Water Content (L)
Approx Dry Weight (kg)
Front (mm)
125
125
RC11/2
250
RC2
350
RC2
450
19.8
29.7
29.7
39.7
546.1
900
25
39.7
49.5
59.4
328.3
466.4
466.4
546.1
715.6
794.6
Back (mm)
Boiler
Clearances
Left (mm)
500
500
Right (mm)
Option Kits
Boiler
Super Plus
Water flow switch for boiler protection in
the event of pump failure
✓
✓
✓
Remote indication of boiler on,
lockout and overheat for each module
Module blanking off pack
15
pressure jet
Buccaneer GTE 21 - 39kW
• Natural gas, oil fired or dual fuel
• High efficiency
• Minimal emissions
• Compact size
• Comprehensive control
• Low temperature operation
General Data Buccaneer GTE (21 - 39)
Model
GTE 4
GTE 5
5
GTE 6
6
Sections
4
Output (kW)
21 - 27
27 - 33
835
570
939
R11/4
4
32 - 39
Height (mm)
Width (mm)
Depth (mm)
812
1066
Flow/Return Connections (BSP)
Maximum Working Pressure (bar)
Flue Size (mm)
Water Content (L)
Approx Dry Weight (kg)
Front
125
24.5
182
125
30.0
210
1000
500
500
500
153
35.5
238
Back (mm)
Boiler
Clearances
Left (mm)
Right (mm)
Option Kits
Boiler
Buccaneer GTE
DHW sensor
✓
16
Falcon GTS 40-100kW
• Natural gas or oil fired
• High efficiency
• Minimal emissions
• Compact size
New
Model
• Comprehensive control
• Low temperature operation
General Data Falcon GTS (40 - 100)
Model
GTS 4
GTS 5
5
GTS 6
GTS 7
7
GTS 8
8
Sections
4
6
Output (kW)
40-50
50-64
64-78
1100
520
1026
R11/2
4
78-92
92-100
Height
Width
Depth
772
899
1153
R11/2
1280
R11/2
Flow/Return Connections (BSP)
Maximum Working Pressure (bar)
Flue Size (mm)
Water Content (L)
Approx Dry Weight (kg)
Front (mm)
R11/4
R11/4
153
36
153
43
180
50
180
57
180
64
254
296
344
1000
500
500
500
381
423
Back (mm)
Boiler
Clearances
Left (mm)
Right (mm)
Option Kits
Boiler
Falcon GTS
DHW sensor
✓
17
pressure jet
Harrier GTE 105 - 330kW
• Natural gas, oil fired or dual fuel
• High efficiency
• Minimal emissions
• 3 pass heat exchanger
• Compact size
• Meets Building Regulations 2006 (Part L2)
General Data Harrier GTE (105 - 330)
Model
GTE5
GTE6
6
GTE7
GTE8
8
GTE9
9
Sections
5
7
Output (kW)
140
180
230
280
330
Height
1297
Width
796
Depth
1151
180
1311
180
1471
1631
200
1791
200
Flow/Return Connections (DN flange)
Flue Size (mm)
Maximum Working Pressure (bar)
Water Content (L)
Approx Dry Weight (kg)
Front (mm)
65
200
6
116
748
136
906
156
176
196
1043
1165
1289
1500
Back (mm)
Boiler
Clearances
1000
100
Side - non hinge (mm)
Side - door hinge (mm)
500 or 200 + burner length
Option Kits
Boiler
Harrier GTE
Hours run meter(s)
✓
✓
✓
✓
De Luxe control panel (High / Low operation)
Flue gas thermometer
GT Condenser
18
Viceroy GT 300 - 780kW
• Natural gas, oil fired or dual fuel
• High efficiency
• Minimal emissions
• 3 pass heat exchanger
• Compact size
• Meets Building Regulations 2006 (Part L2)
General Data Viceroy GT (300 - 780)
Model
GT8
GT9
GT10
10
GT11
11
GT12
12
GT13
13
GT14
14
Sections
8
9
Output (kW)
390
450
540
600
1695
1000
1985
100
300
6
670
720
780
Height
Width
Depth
1505
75
1665
75
1825
75
2145
100
2305
100
2465
100
Flow/Return Connections (mm)
Flue Size (mm)
Maximum Working Pressure (bar)
Water Content (L)
Approx Dry Weight (kg)
Front (mm)
250
250
250
300
300
300
366
409
2028
2000
452
2524
2000
495
2492
2000
1000
500
500
538
581
624
1941
1500
2653
2500
2881
2500
3117
2500
Back (mm)
Boiler
Clearances
Left (mm)
Right (mm)
Option Kits
Boiler
Viceroy GT
Hours run meter(s)
✓
✓
✓
✓
De Luxe control panel (High / Low operation)
Flue gas thermometer
GT Condenser
19
pressure jet
Viscount GTE 754 - 1450kW
• Natural gas, oil fired or dual fuel
• Meets Building Regulations 2006 (Part L2)
• Minimal emissions
• 4 pass heat exchanger
• Comprehensive control
• Low temperature return
General Data Viscount GTE (754 - 1450)
Model
GTE14
GTE15
GTE16
GTE17
GTE18
18
GTE19
19
GTE20
20
GTE21
21
GTE22
22
GTE23
23
GTE24
24
GTE25
25
Sections
14
15
16
17
Output (kW)
812
870
928
986
1044
1102
1160
1760
1172
2845
159
1218
1276
1334
1392
1450
Height
Width
Depth
2105
139.7
450
2245
139.7
450
2355
139.7
450
2445
139.7
500
2555
159
2645
159
2955
159
3045
159
3155
159
3245
159
3355
159
Flow/Return Connections (mm)
Flue Size (mm)
Maximum Working Pressure (bar)
Water Content (L)
Approx Dry Weight (kg)
Front (mm)
500
500
500
500x700max 500x700max 500x700max 500x700max 500x700max
6
655
693
731
769
807
845
905
943
981
1019
4951
1057
5140
1095
5340
3218
3430
3629
3814
3950
4128
4369
1500
936
4567
4755
Back (mm)
Boiler
300
436
436
656
656
656
936
936
1266
1266
1266
Clearances
Side - non hinge (mm)
Right (mm)
500
1200
Option Kits
Boiler
Viscount GTE
Hours run meter(s)
✓
✓
✓
✓
De Luxe control panel (High / Low operation)
Flue gas thermometer
GT Condenser
20
Vanguard L 130 - 3500kW
• Steel shell construction
• Natural gas, oil fired or dual fuel
• One or two stage operation
• High efficiency 91% net (82% gross)
• Reverse flame combination chamber design
• Easy to install and service
• Meets Building Regulations 2006 (Part L2)
General Data Vanguard L (130 - 3500)
Model
170
240
290
340
420
510
630
760
870
970
1100 1320 1570 1850 2200 2650 3000 3500
Output (kW)
170
240
290
340
420
510
630
760
870
970
1100 1320 1570 1850 2200 2650 3000 3500
Height
1272 1272 1372 1372 1542 1542 1542 1622 1622 1622 1622 1622 1732 1732 1892 1892 2080 2340
Width
820
820
860
860
890
890
890
1122 1122 1122 1352 1352 1462 1462 1622 1622 1670 1920
Depth
1214 1474 1411 1541 1606 1801 2113 1989 2184 2379 2346 2686 2781 3151 3225 3545 3835 3879
Flow/Return Connections (DN flange)
Flue Size (mm)
Maximum Working Pressure (bar)
Water Content (L)
Approx Dry Weight (kg)
Front (mm)
65
65
80
80
100
250
100
250
100
250
125
350
125
350
6
125
350
150
400
150
400
175
450
175
450
200
520
200
520
200
570
200
620
200
200
250
250
190
435
251
510
264
588
298
629
398
796
462
919
565
671
753
836
1040 1242 1418 1617 2086 2324 2553 4862
1047 1341 1447 1553 1821 2030 2780 3280 4145 4465 5110 6700
Same length as boiler
500
Back (mm)
Boiler
Clearances
Side - non hinge (mm)
100
Right (mm)
200 + burner length
21
Stelrad Radiators
Stelrad Radiators
Stelrad is the UK market leader in central heating radiators, offering the
widest range, and in more sizes, than any other manufacturer. Our highly
advanced production and distribution facility in Mexborough, UK, produces
over 2.5 million steel panel radiators a year, for both Domestic and
Commercial markets.
From the classic, traditional Elite to the sophisticated, stylish Excel - Stelrad
has a variety of styles and finishes to harmonise with any period or
contemporary setting.
The Stelrad Team
Radiators
Tel: 08708 498056
Fax: 08708 498058
Spares Sales
Tel: 01482 498665
Technical Information
Tel: 01482 498663
email: info@stelrad.com
Website
You’ll find information here on the entire product range; user guides,
installation and mounting instructions, servicing manuals and technical
product data, available options; as well as the services we offer in support of
our products.
You will find the website located at:
www.stelrad.com
22
quality, choice & style
Ladder &
Mini Ladder STR
Bergamo
•
•
•
•
•
28 Models
•
•
•
•
•
5 Models
•
6 Models
Heights 698 - 1800mm
Lengths 400, 500 & 600mm
Output 240 - 1022 watts
Types Straight/Curved -
White/Chrome
Heights 645, 745mm
Lengths 425, 625, 825mm
Output 419 - 922 watts
Functional and aesthetically
superior
•
•
•
•
Heights 740, 1172, 1730mm
Lengths 500, 600mm
Output 376 - 940 watts
New flat tube design
•
•
Cost effective
Adds elegance
Vertex
Classic Column
•
•
12 Models
•
•
59 Models
Heights 1604, 1804, 2004,
2204mm
Heights 300, 500, 600,
750, 1800, 2000, 2500mm
Lengths 315 - 1800mm
Output 297 - 3015 watts
Types 2, 3, 4 columns
Chic solution
•
•
•
Lengths 445, 580, 715mm
Output 1110 - 2304 watts
Type P2
•
•
•
•
23
Traditional
Data & Dimensions
ٌ
Elite
Height Length
Output Watts at Δ T50
(mm)
(mm)
K1
P+
K2
P1
300
300
300
300
300
300
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
500
1000
1500
2000
2500
3000
400
259
517
388
776
506
•
•
1012
1518
2024
2530
3036
564
776
1164
1552
1940
2328
442
•
1034
1293
1551
307
•
•
•
190
238
286
333
381
428
476
•
500
384
553
705
600
461
664
845
700
538
774
986
800
614
885
1127
1268
1409
1550
1691
1973
2254
2536
2818
3100
3382
3663
3945
4227
711
900
691
995
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
400
768
1106
1217
1327
1548
1770
1991
2212
2433
2654
2876
3097
3318
564
845
922
571
666
762
•
1075
1229
1382
1536
1690
1843
1997
2150
2304
400
952
•
1142
•
•
•
•
•
•
•
•
•
•
216 Models
244
305
366
427
488
549
610
•
500
500
705
889
Heights 300, 450, 600, 700mm
Lengths 400 - 3000mm
Output 190 - 6033 watts
Types P1, K1, P+ & K2
600
600
845
1067
1245
1422
1600
1778
1956
2134
2489
2845
3200
3556
3912
4267
4623
4978
5334
804
700
700
986
800
800
1127
1268
1409
1550
1691
1973
2254
2536
2818
3100
3382
3663
3945
4227
639
900
900
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
400
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
457
732
854
976
•
Working pressure - 16psi (8 bar)
10 Year Warranty
1220
•
1464
•
Options
•
See page 31
•
280
350
419
489
559
629
699
•
500
571
799
1006
1207
1408
1609
1810
2011
2212
2413
2815
3218
3620
4022
4424
4826
5229
5631
6033
600
685
958
700
799
1118
1278
1437
1597
1757
1916
2236
2555
2875
3194
3513
3833
4152
4472
4791
800
914
900
1028
1142
1256
1370
1599
1827
2056
2284
2512
2741
2969
3198
3426
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
839
979
1118
•
1398
•
1678
•
•
•
24
Data & Dimensions
ٌ
Compact
Height Length
Output Watts at Δ T50
(mm)
(mm)
K1
P+
K2
P1
300
300
300
300
300
300
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
450
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
500
1000
1500
2000
2500
3000
400
255
509
373
745
491
•
•
982
764
1118
1490
1863
2235
422
1473
1964
2455
2946
548
•
1018
1273
1527
302
•
•
•
190
237
284
332
379
427
474
•
500
378
528
686
600
454
633
823
700
529
739
960
800
605
844
1097
1234
1371
1508
1645
1919
2194
2468
2742
3016
3290
3565
3839
4113
693
900
680
950
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
400
756
1055
1161
1266
1477
1688
1899
2110
2321
2532
2743
2954
3165
538
832
907
569
664
758
•
1058
1210
1361
1512
1663
1814
1966
2117
2268
392
948
•
1138
•
•
•
•
•
•
•
•
•
•
216 Models
248
310
371
433
495
557
619
•
500
490
673
866
Heights 300, 450, 600, 700mm
Lengths 400 - 3000mm
Output 190 - 5883 watts
Types P1, K1, P+ & K2
Working Pressure - 16psi (8bar)
10 Year Warranty
600
588
807
1039
1212
1386
1559
1732
1905
2078
2425
2771
3118
3464
3810
4157
4503
4850
5196
784
700
686
942
800
784
1076
1211
1345
1480
1614
1883
2152
2421
2690
2959
3228
3497
3766
4035
612
900
882
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
400
980
1078
1176
1372
1568
1764
1960
2156
2352
2548
2744
2940
447
743
867
990
•
1238
•
1486
•
Options
•
See page 31
•
286
358
429
501
572
644
715
•
500
559
765
981
600
670
918
1177
1373
1569
1765
1961
2157
2353
2745
3138
3530
3922
4314
4706
5099
5491
5883
700
782
1071
1224
1377
1530
1683
1836
2142
2448
2754
3060
3366
3672
3978
4284
4590
800
894
900
1005
1117
1229
1340
1564
1787
2011
2234
2457
2681
2904
3128
3351
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
858
1001
1144
•
1430
•
1716
•
•
•
25
low surface temperature
Data & Dimensions
LST Standard
ٌ
Height
Emitter
Height
(mm)
Length
Output Watts at Δ T50
(mm)
(mm)
K1
P+
K2
500
500
500
500
500
500
500
500
650
650
650
650
650
650
650
650
800
800
800
800
800
800
800
800
300
300
300
300
300
300
300
300
450
450
450
450
450
450
450
450
600
600
600
600
600
600
600
600
560
760
196
293
284
426
348
522
960
391
568
696
1160
1360
1560
1760
1960
560
489
710
870
587
852
1044
1218
1392
1566
478
685
994
782
1136
1278
386
880
290
760
435
580
717
960
580
773
956
1160
1360
1560
1760
1960
560
725
966
1195
1434
1673
1912
2151
615
870
1159
1352
1546
1739
501
1015
1160
1305
365
760
548
751
922
960
730
1002
1252
1502
1753
2003
2254
1230
1537
1844
2152
2459
2767
1160
1360
1560
1760
1960
913
1096
1278
1461
1643
•
•
•
•
•
•
•
72 Models
Heights 500, 650, 800mm
Lengths 560 - 1960mm
Output 196 - 2767 watts
Types K1, P+ & K2
Safety grilles supplied as standard
Casing supplied with valve/pipework
“knockouts” on side panels
•
•
Flexibility of choice
Competitively versatile
Options
Remote sensing thermostatic valves
26
Data & Dimensions
ٌ
LST Plus
Model Height
Height Emitter Length Emitter
Output Watts at Δ T50
(mm) inc Kick Grille Height
(mm)
Length
(mm)
K1
P+
K2
(mm)
(mm)
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
500
600
600
600
600
600
600
600
600
500
500
500
500
500
500
500
500
650
650
650
650
650
650
650
650
750
750
750
750
750
750
750
750
300
300
300
300
300
300
300
300
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
650
850
400
600
203
304
406
507
608
710
811
913
264
397
529
661
793
925
1058
1190
336
503
671
839
1007
1175
1342
1510
290
435
362
542
1050
1250
1450
1650
1850
2050
650
800
580
723
1000
1200
1400
1600
1800
400
725
904
870
1085
1266
1446
1627
456
1015
1160
1305
388
850
600
581
685
1050
1250
1450
1650
1850
2050
650
800
775
913
1000
1200
1400
1600
1800
400
969
1141
1369
1597
1825
2054
558
1163
1357
1550
1744
461
850
600
692
837
1050
1250
1450
1650
1850
2050
800
922
1116
1395
1674
1953
2232
2511
1000
1200
1400
1600
1800
1153
1384
1614
1845
2075
•
•
•
•
•
•
•
•
72 Models
Heights 500, 650, 750mm
Lengths 650 - 2050mm
Output 203 - 2511 watts
Types K1, P+ & K2
Specialised integrated features as standard
Complete pre-assembled package
Unique design ensuring safety
and fast installation
Disabled Adaptor
The disabled adapter comes as standard and is
designed to aid those who may find it difficult to
manoeuver the standard control.
Blanking Cap
Each LST 2 has a blanking cap which
can be used to make the LST 2 totally
tamper proof.
TRV - Lockable
Kick Grilles
The TRV within the LST 2 can be locked
at any temperature within the range so
that performance and comfort levels can
be maintained. Also comes with 2m
remote sensing capiliary as standard.
Optional kick grilles are provided on the
two larger models and can be used as
either full unit grilles or simply pipe
cores.
27
specifier range
Data & Dimensions - Style
Style
ٌ
Height Length
Output Watts at Δ T50
(mm)
(mm)
K1
K2
P+
P2
300
300
300
300
500
500
500
500
500
500
500
500
500
600
600
600
600
600
600
600
600
600
500
1000
1400
2000
400
225
450
435
869
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
630
1217
1738
514
900
290
600
436
772
800
581
1029
1286
1543
1800
2058
2315
2572
597
1000
1200
1400
1600
1800
2000
400
726
871
1016
1162
1307
1452
339
600
508
895
800
678
1194
1492
1790
2089
2387
2686
2984
1000
1200
1400
1600
1800
2000
847
1016
1186
1355
1525
1694
•
•
•
•
•
•
44 Models
Heights 300, 500, 600mm
Lengths 400 - 2000mm
Output 225 - 2984 watts
Types K1 & K2
Data & Dimensions - Style Lo-line
Height Length
Output Watts at Δ T50
(mm)
(mm)
K1
K2
P+
P2
200
200
200
200
500
•
•
•
•
242
483
676
966
307
614
•
•
•
•
1000
1400
2000
Stylish linear design
860
1228
Options
See page 31
Data & Dimensions - Style Vertical
Height Length
Output Watts at Δ T50
(mm)
(mm)
K1
K2
P+
P2
1600
1600
1600
1800
1800
1800
2000
2000
2000
2400
2400
2400
300
500
600
300
500
600
300
500
600
300
500
600
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
707
1062
1228
785
1180
1364
862
1295
1498
1011
1520
1757
28
Data & Dimensions
Planar
ٌ
Height Length
Output Watts at Δ T50
(mm)
(mm)
K1
K2
300
300
300
300
400
400
400
400
400
400
400
400
400
500
500
500
500
500
500
500
500
500
600
600
600
600
600
600
600
600
600
500
1000
1400
2000
400
235
469
465
929
657
1301
1858
471
938
250
600
376
706
800
501
942
1000
1200
1400
1600
1800
2000
400
626
1177
1412
1648
1883
2119
2354
564
751
876
1002
1127
1252
310
600
464
847
800
619
1129
1411
1693
1975
2258
2540
2822
654
1000
1200
1400
1600
1800
2000
400
774
929
1084
1238
1393
1548
364
600
547
980
•
•
•
•
•
•
•
62 Models
800
729
1307
1634
1961
2288
2614
2941
3268
1000
1200
1400
1600
1800
2000
911
Heights 300, 400, 500, 600mm
Lengths 400 - 2000mm
Output 235 - 3268 watts
Types K1 & K2
1093
1275
1458
1640
1822
6 Tappings - Pre-piped TBSE
Flat fronted design
6 Tappings
The planar comes with 6 tappings enabling a multitude
of installation configurations which dramatically reduce
installation time.
Options
See page 31
29
data & dimensions
Data & Dimensions - Plane
Concord
Height Length
Elements
Plane
Plane
(mm)
(mm)
Single
Double
440
440
440
440
440
440
440
440
440
440
440
440
440
440
440
440
440
588
588
588
588
588
588
588
588
588
588
588
588
588
588
588
588
588
736
736
736
736
736
736
736
736
736
736
736
736
736
736
736
736
736
500
600
6
6
382
458
673
808
700
6
535
942
800
6
611
1077
1211
1346
1481
1615
1884
2154
2423
2692
2961
3230
3500
3769
4038
827
900
6
688
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
500
6
764
6
840
6
917
6
1070
1222
1375
1528
1681
1834
1986
2139
2292
500
6
6
6
6
6
6
6
6
8
600
8
599
992
700
8
699
1158
1323
1489
1654
1819
1985
2316
2646
2977
3308
3639
3970
4300
4631
4962
1046
1255
1464
1674
1883
2092
2301
2510
2929
3347
3766
4184
4602
5021
5439
5858
6276
800
8
799
900
8
899
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
500
8
999
•
•
130 Models
8
1099
1199
1399
1598
1798
1998
2198
2398
2597
2797
2997
606
8
Heights 144, 292, 440, 588, 736,
1800, 2000mm
8
8
8
8
8
•
•
•
•
Lengths 320 - 3000mm
8
8
Output 382 - 6276 watts
8
8
Low water content for fast efficient heat-up
High pressure tested to withstand 6.0 bar
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
600
727
700
848
800
970
900
1091
1212
1333
1454
1697
1939
2182
2424
2666
2909
3151
3394
3636
1000
1100
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
Options
See page 31
Data & Dimensions - Lo-Line
Height Length
Elements
Lo-Line
(mm)
(mm)
144
144
144
144
144
144
144
144
292
292
292
292
292
292
292
292
800
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
530
663
Data & Dimensions - Vertical & Slimline
1000
1200
1400
1600
1800
2000
2200
800
Height Length
Elements
Vertical
Slimline
796
(mm)
(mm)
928
1800
1800
1800
1800
1800
1800
2000
2000
2000
2000
2000
2000
320
440
520
588
640
736
320
440
520
588
640
736
8
6
872
1417
1744
978
1061
1193
1326
1459
898
780
1040
1300
870
13
8
16
10
8
1000
1200
1400
1600
1800
2000
2200
1122
1346
1571
1795
2020
2244
2468
11
13
8
1589
1956
1160
1450
30
16
10
radiator options
3
Valves
Stelrad can offer a range of
luxury valves to complement
our design products.
/4” Adaptor
The adaptor enables you to
3
connect to / ” pipework with
4
no detriment to
performance.
Extension Pieces
20/30 and 40mm extension
pieces are available to help
bridge gaps on replacement
installations.
Floor Standing
Brackets
When wall space is at a
premium or has insufficient
load bearing, floor standing
brackets can offer a suitable
alternative.
Continental
Brackets
Top Grilles & Side
Panels
If it is extra security you
need, continental brackets
clean up the top and bottom
seam offering greater
stability.
Can be fitted to Elite
radiators when a more
aesthetic solution is
required.
A full range of options and accessories can be seen by visiting
www.stelrad.com
31
The Ideal Commercial Range
20
40
100 150 200
340 511 682
600
800
1000
3412
1500
5118
3500
kW
Boiler output
Btu/h (000) 68
136
2047
2729
11942
Atmospheric Boilers
Concord CXA/H
40-120
40-120
Concord CXS/H
Concord CXSi/H
110-180
Concord ES/H
140-380
80-720
Concord Modular
High Efficiency Boilers
Concord Super Series 4
Concord Super Plus
Condensing Boilers
50-600
200-600
icos HE
30-36
45-80
W
Concord CXC
48-116
90-310
80-560
p lu s II
x tra
GT Condenser
Pressure Jet Boilers
Buccaneer GTE
Falcon GTS
180-990
21-39
40-100
Harrier GTE
Viceroy GT
105-330
300-780
Viscount GTE
Vanguard L
754-1450
130-3500
Approval
Contact Numbers
Sales
These appliances are certified to
G.A.D. 90/396 and B.E.D. 92/42
safety and performance Directives
for gas boilers.
Tel: 01482 498690
Fax: 01482 498621
Technical
Ideal Boilers pursues a policy of
continuous improvement in design
and performance of its products
and reserves the right to vary
specification without notice.
Statutory rights of the consumer
are not affected.
Tel: 01482 498376
Fax: 01482 498621
Training
Assurance of quality
BS EN ISO 9001: 2000
Tel: 01482 498432
Fax: 01482 498605
Ideal Stelrad Group, PO Box 103, National Avenue, Kingston upon Hull HU5 4JN.
www.idealcommercialboilers.com www.stelrad.com email: commercial_heating@idealboilers.com
Range/7/07 Issued subject to standard conditions
© 2007 Ideal Boilers Limited
|