Gas-Fired, Direct Vent
Hot Water Boiler
(
)
DIMENSIONS in inches
CROWN Co-axial Horizontal Vent Terminal
Air inlet collar located on center rear of CWD193 through CWD245
*
CWD SERIES SPECIFICATIONS
D.O.E
IBR NET
WATER
RATING
BTU/HR.
44,000
62,000
COLLAR
DIAMETER
AGA
INPUT
BTU/HR
NO. OF
SECS.
HEATING
CAPACITY
BTU/HR
WIDTH
A
SHIPPING
WEIGHT
Model
AFUE
INLET
EXHAUST
(inches)
4”
(inches)
(inches)
(%)
CWD060
CWD083
CWD110
CWD138
CWD165
CWD193
CWD220
CWD245
3
4
5
6
7
8
9
10
60,000
82,500
51,000
71,000
94,000
118,000
142,000
165,000
189,000
211,000
3”
3”
3”
16-1/8
19-3/4
23-3/8
27
30-5/8
34-1/8
32-3/4
41-3/8
85.1
85.1
85.2
85.2
85.2
85.2
85.2
85.3
280
315
350
385
420
475
525
580
4”
4”
4”
4”
4”
4”
4”
110,000
137,500
165,000
192,500
220,000
245,000
82,000
103,000
123,000
143,000
164,000
183,000
3”
3” or 4”
3” or 4”
3” or 4”
3” or 4”
LOCATING THE BOILER
• Clearances: Sides 1”, front 3”, rear 1”, top 12”
• 6” clearance to air inlet collar when combustion air is supplied from indoors
• Boiler may be installed directly on a non-carpeted combustible floor
• Relief valve may not be moved from factory location
1. Altitudes above 2,000 ft.–ratings should be reduced at a rate of 4%
for each 1,000 ft. above sea level (U.S.A. only), in Canada, boilers are
certified for altitudes up to 2,000 feet only.
2. Please specify fuel (natural gas or LPG).
3. Specifications and dimensions are subject to change without notice.
Important:This boiler requires a special venting system.
Read instructions carefully before installing.
Heat Exchanger constructed and tested in accordance
with ASME Section IV standard.
AVAILABLE FROM:
Since 1949, homeowners have depended on us
for quality, value and service
3633 I Street, P. O. Box 14818
Philadelphia, PA 19134
Phone: (215) 535-8900 Fax: (215) 535-9736
CWD-11/05-(20M)
PN980528R1
|