CBC ZN LN8048PHA User Manual

ETHERNET CAMERA, MPEG-4  
ZN-L8000  
INSTRUCTION MANUAL  
ZN-L8210PHA  
ZN-L8210NHA  
ZN-LN8048PHA  
ZN-LN8048NHA  
Color or Day/Night High Resolution Camera with Integrated  
Computar Auto-Iris Varifocal Lens & MPEG-4 Streaming Video  
1
INDEX  
INDEX  
3
4
INTRODUCTION  
SAFETY INFORMATION  
PRODUCT DESCRIPTION  
INSTALLATION  
5
6
8
CONFIGURATION WITH WEB BROWSER  
OPERATION WITH INTERNET EXPLORER  
SERVICE  
11  
26  
27  
28  
TECHNICAL SPECIFICATIONS  
v2.0 - English  
3
INTRODUCTION  
This manual is intended for persons authorized to install and operate this camera and  
other VCS products. International, national and any relevant regional regulations relating  
to electronics must be observed at all times.  
Conventions  
In this manual, the following symbols and notations are used to draw attention to special  
situations:  
Attention! This symbol indicates tips and notes that make using the device  
easier and more convenient.  
Hazard! This symbol indicates that failure to follow the safety instructions  
given may directly endanger people, cause damage to the system or to other  
equipment. This symbol represents a direct threat of danger.  
The following typographic conventions are used in this manual:  
Configuration  
[Enter], [C]  
[Ctrl] + [C]  
ping  
menu names and window and key names and parameters  
separate key names  
two or more keys pressed simultaneously  
command line input and output  
-
Intended Use  
This camera is intended to transmit video and control signals via Ethernet data networks.  
This camera is designed for use in CCTV systems.  
The connection of an external alarm sensor allows functions to be triggered automatically.  
Other unauthorized applications are not permitted.  
If you have any additional questions concerning the use of these devices which are NOT  
answered in this manual, please contact your dealer.  
This camera is compatible with following VCS products: VideoJet10e and VIDOS software.  
v2.0 - English  
4
SAFETY INFORMATION  
Electrical Shock Hazard  
Ø Never attempt to connect the unit or the power supply to any power source other  
than the one for which it was provided for.  
Ø Use only appropriate and approved power supply units with this device (see  
technical specifications).  
Ø Do not open the housing of the power supply unit.  
Ø Disconnect the power supply unit from the outlet and from all other devices if a fault  
occurs.  
Ø Install the power supply unit and the device in a dry place, which is protected from  
the elements.  
Ø If you are uncertain about the safe operation of the unit, shut it down immediately  
and secure it to prevent any unauthorized start-up. Safe operation of this unit is no  
longer possible under the following conditions:  
§ If damage is visible to the unit or the cables  
§ If the unit no longer operates correctly  
§ If the unit has been exposed to rain or moisture  
§ If objects have penetrated inside the unit  
§ After long storage under improper conditions or  
§ After heavy demands during transport  
Installation and Operation  
Ø All applicable electrical codes and regulations must be observed and followed at all  
times during the installation of this device.  
Ø Before installing or operating the system, ensure that you have read and  
understand the documentation for all other equipment that will be connected to the  
unit, such as monitors or pan-tilt (PTZ) heads. These documents may contain  
important safety notices and information concerning permissible applications.  
Ø Please only install and operate this device as described in this manual. All other  
work beyond this may lead to injuries to persons and damage to the system or  
other equipment.  
Ø Ensure a secure footing whenever working in elevated positions. Use only  
approved safety ladders. If necessary, use a safety harness or railings.  
Ø Use this camera with original Ganz tools.  
Repairs and Maintenance  
Ø Never open the housing of the unit.  
Ø Never open the housing of the power supply unit.  
Ø Only allow a qualified technician to perform maintenance or repair work.  
Ø Contact your dealer for authorized service or repair.  
v2.0 - English  
5
PRODUCT DESCRIPTION  
System Requirements  
Ø PC with Windows 98/2000/XP operating system and network connection  
Ø Microsoft Internet Explorer web browser (version 5 and up) or serial interface and  
terminal program, e.g. Windows Hyperterminal  
Configuration Requirements  
Ø Computer with Windows 98/2000/XP operating system and network connection  
Ø Microsoft Internet Explorer (version 5 and up) and MPEG-ActiveX plugin  
Operating Requirements  
Ø Computer with Windows 98/2000/XP operating system and network connection  
Ø Microsoft Internet Explorer (version 5 and up) and MPEG-ActiveX plugin  
Ø VideoJet10e with NTSC / PAL monitor or VIDOS software  
Functions  
This device is a high-resolution color or Day/Night camera for professional use in CCTV  
systems. It has an integrated video server for encoding the video and audio signals for  
transfer via an Ethernet LAN.  
The camera’s ¼” CCD offers a horizontal resolution of 480TVL(PAL) / 470TVL(NTSC).  
The camera is characterized by a 2.8-10mm (color) or 4-7.5mm (Day/Night) Computar  
varifocal lens, with DC auto-iris.  
All of the camera settings are accessed via HTML pages using an Internet Web Browser,  
except the anti-flicker function, backlight compensation (BLC) and iris setup.  
Main functions are:  
Ø Automatic DC iris and varifocal lens  
Ø BLC and anti-flicker  
Ø AGC ON/OFF  
Ø Analog video output PAL/NTSC (BNC) for focus and iris setup  
v2.0 - English  
6
Multicast functions  
This camera utilizes MPEG-4 compression technology. Thanks to efficient encoding, the  
data transmission rate remains low, even with maximum image quality at 25 images per  
second; furthermore, it can be adapted to meet the bandwidth requirements of various  
network infrastructures.  
In appropriately configured networks, the multicast function permits the simultaneous video  
transmission in real time to several receivers. A requirement for this to function properly is  
the implementation of the UDP and IGMP protocols on the network.  
Configuration  
This camera can be configured with a browser via the local area network or  
through the Internet. Firmware updates and the quick uploading of device  
configurations are handled in the same way. Please note that disconnecting  
the camera or power supply while the firmware update is still in progress can  
cause serious damage to the camera.  
Summary  
Ø Video and Data Transmission over LAN / WAN networks  
Ø Digitally optimized video data  
Ø Automatic Iris Control  
Ø Integrated Computar Varifocal lens  
Ø Multicast or video streaming multicast connection  
Ø Local analog (NTSC / PAL) video output  
Ø 25 FPS (at high resolution)  
Ø MPEG-4 or M-JPEG  
Ø Integral Ethernet interface 10/100 Base-T RJ-45  
Ø Remote control of internal functions via TCP and UDP  
Ø 3-step Password Protection  
Ø 2 Alarm Inputs (NO or NC)  
Ø 1 Relay (NO or NC)  
Ø Automatic connection on alarm  
Ø Integrated motion detector  
Ø Firmware upgrade by flash memory  
Ø Bi-directional audio transmission  
v2.0 - English  
7
Connectors and Controls  
1
8
3
4
1
2
3
4
USB Port  
Power Supply LED  
Analog Video Output (BNC)  
Day/Night Control Terminal (NO)  
(Only on Day/Night models)  
10/100 Base-T LAN (RJ-45) connector  
Link LED  
5
6
7
8
Transmission LED  
Video termination switch (75 Ohm/High)  
5
7
2
6
6
7
8
9
ALARM IN 2  
Relay  
Relay  
12 V DC  
GND  
1
2
3
4
5
Line Audio In  
GND  
Line Audio Out  
GND  
ALARM IN 1  
1
2
3
4
5
6
7
8
9
10  
10  
6
7
1
2
3
4
5 / 8  
1
2
3
4
DC iris: ON  
5
6
7
8
VR for iris adjustment  
Zoom adjustment  
Focus adjustment  
DC iris connector  
Anti-Flicker: ON/OFF  
BLC: ON/OFF  
Always ON  
v2.0 - English  
8
INSTALLATION  
This camera is designed for indoor operations. Choose a site for installation  
which ensures that the camera is NOT exposed to extreme temperatures or  
extreme moisture or humidity. The ambient temperature must be between  
+40°F and 115°F (+5°C ~ 40°C) and the relative humidity cannot exceed 80%.  
During operation, the unit generates a good amount of heat. Please ensure  
sufficient ventilation and install this device away from heat-sensitive equipment  
or objects.  
Please observe the following installation conditions:  
Ø Do not install the camera in the immediate vicinity of radiators or other sources of  
heat. Avoid installing the camera where it is exposed to direct sunlight.  
Ø Ensure sufficient space for laying the cables.  
Ø Ensure adequate ventilation of the camera.  
Ø For all cable connections, use cables which prevent electrical interference, where  
necessary.  
Ø Ensure that the camera is not exposed to water at the installation site. If necessary,  
use fresh desiccant in waterproof housing to avoid moisture due to condensation.  
Ø Lay and install all cables in such a way that they cannot be damaged and ensure  
sufficient strain relief.  
Ø The camera mounting position always depends on the actual situation. No concrete  
instructions can be given here. The camera has a standard ¼” thread which can be  
installed on both the top and bottom of the housing.  
Ø Lay all cables up to the installation position.  
Ø If necessary, connect a monitor with a coax cable to the BNC jack in order to be  
able to check the video image on the spot (line impedance must be set by the switch  
#8 to HIGH).  
Ø Connect the leads of the power supply unit to terminals + and – of the DC 12V  
CONNECTOR. Pay attention to the correct connection of the leads.  
Network Connection  
You can connect the camera via hub, switch or router to a 10/100 Base-T network. Use a  
standard UTP Category 5 cable with RJ-45 connectors.  
Alarm Inputs, Relay Output  
The alarm inputs of the camera will allow you to connect to an external alarm trigger. If  
configured accordingly, an alarm trigger can, for example, set up an automatic connection  
between the camera and a remote station.  
v2.0 - English  
9
The relay output allows for switching external devices. This control output can be used  
interactively during an active connection with the camera. The contact can be programmed  
as normally open (NO) or normally closed (NC) and it is possible to invert the mechanical  
function by software setup.  
The relay contact must not be subjected to a load of more than 40V and 0.8A.  
Power Supply  
This camera has no master power switch. When you have connected the power supply  
unit to the device and insert the power plug into a socket, the device is powered on and  
ready for operation.  
Assigning the IP Address  
Ø Start the ‘Jet Manager’ program.  
Ø Click on ‘scan’ icon.  
Ø Select the desired ‘ZN-L8000’ and right-click to bring up the context menu.  
Ø Click on “Change IP Address”.  
Ø Click on “IP Pool” if you have not yet specified a valid IP address range and set it.  
Ø Select “Set manually” and choose a valid IP address.  
Ø Click on “OK”  
Ø Wait few seconds and click again on ‘scan’ icon to view new IP address in the list.  
Ø Select again the ‘ZN-L8000’ and right-click, selecting “View in Browser” to view the  
camera in Microsoft Internet Explorer.  
Day / Night Manual Control Function  
Only the ZN-LN8048PHA and ZN-LN8048NHA Day / Night Models feature the N.O. input  
terminal (#4). This terminal will manually switch the camera from color (open contact) to  
B&W (closed contact). When this terminal is closed, the camera switches into Night Mode  
and adjusts the DC iris by fixing the AES speed.  
When the camera switches to Night Mode automatically, the DC iris is completely opened  
and the AES speed is adjusted by the camera.  
v2.0 - English  
10  
CONFIGURATION WITH WEB BROWSER  
Making the Connection  
The integrated HTTP server offers you the possibility of configuring the camera over the  
network with a web browser. This possibility is far more convenient than the configuration  
via the terminal program and also allows you to view live video images.  
In order for live video images to be decoded, the special MPEG ActiveX control  
required must be installed on the computer. The latest version of the MPEG  
ActiveX control may be installed from the supplied CD, or downloaded from our  
website. Notes on operation of the web browser can be found in the online  
help file.  
System Requirements  
Ø Microsoft Internet Explorer (version 5 and up)  
Ø Microsoft Java Virtual Machine (in case of Windows Pro XP, your dealer can provide  
you this software)  
Ø Network connection  
Establishing the Connection  
To use the camera on the network, it must be provided with an IP address.  
The following address has been preset at the factory:  
IP Address  
Subnet Mask  
Gateway  
192.168.0.1  
255.255.255.0  
0.0.0.0  
Type the camera’s IP address into the web browser’s address bar. If the address is not  
compatible with your network, you can easily change it using the JetManager software that  
you can download from our website.  
Configuration  
Once the Livepage has loaded, click on Settings to view the configuration pages.  
v2.0 - English  
11  
Click on the items in the left gray bar to navigate the configuration pages. The pages are  
divided into categories; click on each category and then on the desired subject.  
To save your changes, it is necessary to click the Set button on each screen  
before moving on to another category of settings.  
Unit Identification ó General Settings  
Unit name:  
Enter a name for the camera to aid in identification in multiple camera systems.  
Unit ID:  
Each device can be assigned a unique identifier which can be used to identify it.  
v2.0 - English  
12  
Unit Identification ó Password Settings  
Password level:  
Access to the camera is generally protected with a password in order to prevent  
unauthorized use of the device. The transmitters operate with three authorization  
levels: Live, User and Service.  
Service - for configuration, services control and live picture.  
User - for services control and live picture.  
Live - for live picture only.  
Password:  
You can define and change passwords for access to the device when you are  
working with the authorization level ‘Service’ or if the device is not protected with a  
password. Please enter the password.  
Password Confirm:  
Type the new password again and click Set.  
Unit Identification ó Language Settings  
Website language: select the desired language of the HTML pages.  
Unit Identification ó Time Settings  
If a number of cameras are combined in a system, it is important that the internal clocks of  
the separate units are all synchronized.  
Date Format:  
select here the desired date format, based on your country.  
Europe: DD.MM.YYYY USA: MM.DD.YYYY Japan: YYYY.MM.DD  
Unit Date/Time: manually enter the date and time or click on Synchr. PC to update the  
date and time, in synchronization with the PC’s current date and time.  
v2.0 - English  
13  
Unit Identification ó Time Server Settings  
The camera can receive a time signal from an NTP server and use it to set the internal  
clock. The device calls up the time signal automatically every two hours.  
Time zone:  
select the current time zone.  
Time server IP address:  
enter the IP address of the NTP server.  
Display Settings ó Camera name  
Camera 1:  
Enter here the camera name, click Set.  
Display Settings ó Display stamping  
You can configure the device so that the camera name, time and alarm source are  
displayed on the video image. Select Top if the names are to be displayed at the top of the  
image, or Bottom if the names are to be displayed at the bottom of the image. If you do not  
wish the names to be displayed, select Off.  
Camera name stamping:  
Camera name is shown in the LH corner of the video image.  
Time stamping:  
Date and time are shown in the RH corner of the video image.  
Alarm mode stamping:  
Select On to display the alarm source (e.g. motion alarm) in the video image.  
Select Off to not display the alarm source.  
Displayed alarm message:  
The text that should be displayed during an alarm event.  
v2.0 - English  
14  
Video/Audio Settings ó MPEG-4 Encoder  
The data transmission parameters can be configured to suit the local operating  
environment (e.g. network architecture, bandwidth, data structures).  
The ZN-L8000 camera can provide you the power of 2 independent MPEG-4 Encoders that  
you can use at different transmission bandwidths, resolutions, etc. for remote transmission,  
local transmission or recording, in order to optimize your system and network usage.  
Name of first/second encoder:  
Enter a name for the selected encoder  
Parameter preset:  
Input a name for the selected setup to recall it later.  
Datarate:  
Select the desired data rate (max 5000 Kbits per second, about 5 Mbps.)  
Video quality settings:  
Here you can select if the camera can automatically optimize the video quality or set  
this value manually. In Manual mode, move the bar close to “High” if you prefer  
picture quality over video refresh or otherwise (“Low”) you prefer good refresh rate  
over picture quality.  
Intra frame distance:  
The number of frames to be sent between two Intra-frames.  
Frame skip ratio:  
With this parameter you define which frames are encoded. If '1' is selected all  
images are encoded. When '2' is selected only every other image is encoded, etc. -  
the lower the bandwidth the higher this value should be in order to have highest-  
quality video.  
v2.0 - English  
15  
Video resolution:  
You can choose between these resolutions:  
Low 176 x 144 pixels (QCIF)  
Standard 352 x 288 pixels (CIF)  
High 704 x 288 pixels (2CIF)  
Reset this parameter preset:  
When the 'Default' button is pressed, the parameters for the selected profile are  
reset to the factory default values.  
If the MPEG ActiveX control is not installed on your computer, a corresponding  
message will be displayed when you switch to the live image page. The latest  
version of the MPEG ActiveX control may be installed from the supplied  
software CD, or downloaded free from our website.  
Video/Audio Settings ó Video Input Settings  
If a local analog video output connector is used, this page will allow you to open the line 75  
Ohm termination to use with other devices. Please set to On if external video peripherals  
are not being used (this setting must be identical to the position of the external 75  
Ohm/High impedance video line termination switch).  
Video/Audio Settings óAudio Settings  
Activate audio:  
Switch this option On if you want to send an audio stream along with the MPEG-4  
video. Transmitting audio requires additional bandwidth of approximately 80 Kbps.  
When audio is set to On, it is stored together with the video stream when centralized  
recording is active; audio can not be recorded on local storage media.  
Alarm settings ó Alarm sources  
v2.0 - English  
16  
Video loss alarm:  
Select the option On if the unit is to activate an alarm when the video signal is  
interrupted.  
Unified picture detection:  
This function constantly checks the contrast of the video image and triggers an  
alarm when the video is locked, for example, when the lens is covered.  
Motion alarm:  
Select On if the unit is to activate an alarm when the motion alarm is triggered.  
Alarm input 1/2:  
Select the option On in order to activate the alarm by means of an external alarm  
sensor. Otherwise select Off. If this setting is turned On, you must also select if the  
alarm is activated by an Active high or Active low voltage level. Enter into the text  
field a message for the alarm input which will be displayed on screen if an alarm is  
activated.  
Alarm Settings ó Alarm Connections  
Options are provided to specify the behavior of the devices in the event of an alarm.  
Connect on alarm:  
Select On, to automatically establish a connection to one of the predefined IP  
addresses in the event of an alarm. The addresses will be contacted in turn once  
until a connection is established.  
Select Assign IP to input if you want a predefined allocation of alarm input and  
remote IP address. Thereby only one remote IP address will be contacted in case of  
an alarm, namely the first IP address with alarm input 1 being triggered, the second  
with alarm input 2 and so on.  
Choosing the parameter Follow input 1, a connection to the first IP address is  
established when alarm input 1 is triggered and holds only until there is a contact at  
alarm input 1. For example, the connection is established if a push-button connected  
to alarm input 1 is activated and will be disconnected automatically when the button  
is turned off.  
Number of video receiver address:  
The ZN-L8000 can store up to 10 alarm IP addresses. In case of an alarm, the  
addresses are contacted one after the other until a connection is established.  
v2.0 - English  
17  
Alarm IP address:  
You can enter the IP addresses of a possible receiver.  
Remote receiver password:  
Here you can enter the respective receiver password in case the receiver is  
protected by one.  
Live video auto-connect:  
Select the option On if it is required to re-establish a connection to the previously  
specified IP address after each restart, e.g. after a connection breakdown or network  
dropout. The addresses will be contacted in turn once until a connection is  
established.  
Alarm settings ó Motion detector  
The camera contains an integrated video sensor, which based on the video processing can  
register changes in the video signal. These changes are primarily initiated by movement in  
the field of view of the camera. The sensitivity of the video sensor can be adjusted, so that  
an alarm is generated only if a given threshold is exceeded.  
In order for the alarm to operate, the following conditions must be fulfilled:  
Ø motion detection must be activated.  
Ø at least one cell must be activated.  
Ø parameters must be matched to environmental conditions and to required responses.  
Ø the sensitivity must be set to a value greater than 0.  
Light reflections, switching on or off of floodlights or light level changes caused  
by cloud movement in bright daylight can cause undesirable responses from  
the video sensor and thereby generate false alarms. Test for different day and  
night time conditions in order to ensure correct operation of the video sensor.  
For surveillance of indoor areas, ensure a constant lighting of the areas during  
the day and at night. Uniform surfaces without contrast can trigger false alarms  
even with uniform lighting.  
v2.0 - English  
18  
Motion detector:  
Select the option On to activate the video sensor.  
Select sensor field:  
The areas of the image to be monitored by the video sensor are selected here. The  
video frame is subdivided into 396 square cells. Each of these cells can be  
activated or deactivated. If it is necessary to exclude particular regions of the  
camera field of view from the monitoring process because of, say, continuous  
movement (e.g. due tree movement in a wind), the relevant cells can be deactivated  
(use mouse click for this operation)  
Local sensitivity:  
The basic sensitivity of the video sensor can be adapted for the ambient camera  
conditions. The sensor reacts to brightness variations in the video image. The  
darker the observation range, the greater the value that must be selected here.  
Adjust the sensitivity by moving the slider to the desired setting with the mouse key  
held down.  
Average n [frames]:  
It is possible to define the number of frames during which a movement is monitored  
in order to generate an alarm. In this way, it is possible to prevent generating a false  
alarm, e.g. by a bird flying across the surveillance area. Select the desired value by  
moving the slider to the desired position with the mouse key held down.  
Object min size [n*] blocks:  
The number of sensor cells, which a moving object must cover in order to generate  
an alarm, can be specified. In this way it is possible to prevent too small objects from  
producing an alarm. For this, the minimum recommended value is 2 (2 × 2 sensor  
fields). Select the desired value by moving the slider to the desired position with the  
mouse key held down.  
Alarm indicator:  
To prevent false alarms, a motion signal can be matched to a given alarm threshold.  
In this way, for example, it is possible to filter out effects caused by the background  
noise generated in the camera itself. The blue line indicates the alarm threshold.  
Any value greater than this will produce an alarm signal. The components of the  
motion signal generating the alarm are indicated in red. The alarm threshold can be  
varied to suit individual requirements.  
Take note of the amplitude of the movement signal displayed in the window over a  
long period and at all light levels likely to be encountered in practice. Move the  
mouse pointer onto the blue line. Holding the left mouse button pressed, move the  
blue line to the required position.  
Motion tracking:  
For certain applications, it can make sense to generate an alarm only if movement  
takes place in a particular direction. You can activate the motion detection and  
select the direction of movement required to generate an alarm. Select the option  
On, in order to activate the motion tracking feature of the video sensor.  
v2.0 - English  
19  
Tracker:  
In the Tracker field you see an arrow, which indicates the current motion in the  
video image. By means of check boxes in the four corners, the desired direction can  
be activated. If, for example, all movements to the “left” and “upwards” are to  
activate an alarm, then mark the top left corner. If all movement to the “left” is to  
activate the alarm, then check the left upper and the lower left corners. Note the  
movements indicated by the arrow in the video image over a long period and at all  
light levels likely to be encountered in practice. Click the check box in order to  
activate the corresponding directional component.  
Relay Setting ó Relay Configuration  
The switching conditions for the relay output can be configured. The function of an open  
switching relay (normally closed contact) or a closed switching relay (normally open  
contact) can be specified. It is also possible to specify whether the output should operate  
as a bistable or as a monostable. In bistable operation, the activated state of the relay  
remains as switched. In monostable operation, the time can be selected after which the  
relay is to revert to its steady state. Various events can be selected to automatically  
activate the output. In this way, for example, it is possible to switch on a floodlight when a  
motion alarm has been detected and to switch the light off again at the end of the alarm.  
Please note that changing the default configuration the relay will work as set when the  
camera is powered on but as indicated in the previous session when powered off.  
Idle state:  
Select Open if the relay is to operate as a normally open contact or Closed if it is to  
operate as a normally closed contact.  
Operating mode:  
Select the operating mode for the relay. If, for example, a lamp is switched on by an  
alarm and is to remain on when the alarm has ended, select Bistable. If an acoustic  
signal activated by an alarm is to remain on for a period of, for example, 10 seconds,  
select 10 s.  
Relay follows:  
Select a particular event by which the relay is to be activated as required.  
v2.0 - English  
20  
The following events can activate the relay:  
Ø Off: No relay triggering by events  
Ø Connection: Triggering if any connection is established  
Ø Video alarm: Triggering caused by loss of the video signal  
Ø Motion alarm: Triggering by the motion alarm  
Ø Local input: Triggering caused by an external alarm sensor  
Ø Remote input: Triggering by a switching contact from a remote location.  
Relay name:  
The relay can be assigned a name here. The name will be shown on the live page,  
depending upon the configuration.  
Trigger relay:  
Click on the button Relay to manually switch the relay (e.g. for test purposes or to  
operate a door opener).  
Service Settings ó Network Settings  
Unit IP address:  
the unit’s IP address.  
Subnet mask:  
the unit’s Subnet mask.  
Gateway IP address:  
Video/Audio transmission:  
the gateway IP address (usually the router or firewall)  
If the device is used in front of a firewall, transmission over TCP (Port 80) should be  
selected. If used in a local network select UDP.  
Ethernet link type:  
Adjust the type of Ethernet link to the network. In most applications, 'Auto' is the  
correct choice. For some routers and switches it may be necessary to set the  
Ethernet link type to a fixed value.  
Select the appropriate value:  
10 MBit/s HD = 10 Mbps half-duplex  
10 MBit/s FD = 10 Mbps full-duplex  
100 MBit/s HD = 100 Mbps half-duplex  
100 MBit/s FD = 100 Mbps full-duplex  
v2.0 - English  
21  
DNS Server IP Address:  
When working with a device over the Internet, dynamic IP addresses are assigned  
for efficient use of the IP address pool, i.e. the device gets a new (changing) IP  
address each time a connection is set up. Connecting is easier when the device is  
listed on a DNS server. The device logs in regularly, leaving the device name,  
device IP address and the current Internet IP address.  
To connect to a device over the Internet you just insert the device name together  
with the URL of the DNS server, which then returns the valid Internet IP address for  
automatic connection set up. The default setting for the DNS server IP address is  
the IP address of the VCS DNS server videotec.info. The ZN-L8000 contacts the  
server automatically when a refresh time is specified in the next parameter. The IP  
address of the VCS DNS server is 195.145.107.78.  
DNS refresh time: enter here the time interval for the ZN-L8000 to contact the DNS  
server. You can enter a value from 30 to 86400 sec (24 h). Leave  
this field empty if you don't want to use the DNS function.  
Multicast operation is only possible using the UDP protocol. The TCP  
protocol does not support any multicast connection.  
Due to settings inside this device, the following ports in your network have to be opened:  
TCP (Port 80): port 80  
UDP (without Multicast): all UDP ports starting with port 1024 and TCP port 1756.  
UDP (with Multicast): the defined Multicast video port and the consecutive 7 ports.  
Service Settings ó Multilink – Multicast  
Along with a 1:1 connection between a transmitter and a receiver (unicast), the units  
provide the option of connecting a number of receivers to simultaneously receive the video  
signal. This is achieved either by a duplication of the data stream in the unit with  
subsequent distribution to a number of receivers (multi-unicast) or by distribution of a single  
data stream on the network itself to a number of receivers in a defined group (multicast).  
Requirement for multicast operation is a multicast compliant network with  
implementation of the UDP protocol and the IGMP protocol. Other group  
management protocols are not supported. The TCP protocol does not support any  
multicast connection.  
v2.0 - English  
22  
The devices support the multi-unicast operation up to a maximum of 5 simultaneously  
connected receivers for MPEG-4. The transparent data connection is maintained from the  
first unit. However, after 15 seconds of inactivity the data connection is automatically  
suspended and another unit can exchange transparent data with the transmitter.  
For multilink operation, the network is not required to be multicast compatible as the  
devices are also multi-unicast compatible. Duplication of the data in the unit requires  
considerable processor power and, under certain circumstances, leads to limitations in the  
picture quality.  
Multicast streaming:  
Select the option On in order to activate the multicast function. For that purpose a  
valid Multicast group IP address has to be entered.  
Multicast group IP address:  
Before you and use the multicast and the streaming mode in a multicast-compatible  
network, you must establish a special IP address (class D address). The network  
must support the establishment of a group IP address and the Internet Group  
Management Protocol (IGMP). The address range is from 224.0.1.0 to  
238.255.255.255. With this field left empty (0.0.0.0) the device is sending in multi-  
unicast mode and streaming is not possible.  
Multicast port MPEG-4:  
This field is read-only and informs about the selected video port. Assignment of port  
numbers is done automatically by the software.  
Multicast racket TTL:  
Here the number of junctions can be entered a data packet can pass within the  
network. By setting the parameter you determine the life span of the data packets,  
e.g. if multicast is operated over a router the value must be greater than 1 to  
guarantee transmission of the packets.  
Service Settings ó Version Information  
Hardware and software version numbers are only required for information and can not be  
altered. Keep a record of these numbers in case technical assistance is required.  
v2.0 - English  
23  
Service Settings ó Livepage Settings  
The live page can be set up to suit individual requirements. Options are provided here to  
display different information and operating elements along with the video picture. In  
addition, individual background images for the main window and for the upper screen area  
(banner) can be used.  
For the background image you can use the file types GIF and JPEG. The file  
paths must correspond to the type of access (for access to a locally stored file,  
for example, c:\Images\Logo.gif, for access to an Internet/Intranet file, for  
example, http://www.cbcamerica.com/images/logo.gif). Note that with Internet  
or Intranet access, the connection must be maintained in order to continually  
display the image. The image files are not stored in the device.  
Start page background URL:  
Enter the file path to a suitable background image. The image can be stored on a  
local computer, on a local network or at an Internet address.  
Start page logo URL:  
Enter the file path to a suitable image for the upper screen area (banner). The image  
can be stored on a local computer, on a local network or at an Internet address.  
Video from Encoder on live page:  
Select the encoder you want to use for viewing in the web browser, on the livepage.  
Select all items that you want to view on the Livepage; you have choice of alarm,  
relay, show alarm messages and show general messages. (all shown by default)  
Save alarm logfile to hard disk:  
Select this option to store alarm data in a text file on the local computer.  
v2.0 - English  
24  
Save general logfile to hard disk:  
Select this option to store the logfile in a text file on the local computer.  
File for saving alarm messages:  
Enter the path to the location where the log files for the alarm messages are stored.  
File for saving general messages:  
Enter the path to the location where the log files for the general system messages  
are to be stored.  
Path for JPEG/MPEG-4 files:  
Enter the path to the storage location for the JPEG snapshots and video sequences  
which can be stored from the live page or the DRAM-Replay.  
Service Settings ó Software Update  
Software upload:  
The units are designed in such a way that their functions and parameters can be  
updated with firmware (device software). In such cases, transmit the updated  
firmware package via the selected network to the device. On termination of the  
connection, the firmware will be automatically installed. This allows a device to be  
remotely serviced and updated without a technician having to modify the device  
installation on site.  
Before starting the firmware upload, ensure that you have selected the correct  
upload file! An upload of other files can result in the device being no longer  
addressable and having to be replaced. Please remember that you can damage  
a camera interrupting a firmware upload.  
Configuration download:  
You can store the configuration setting of the device on a PC and upload stored  
configuration settings from a PC to the device. (Click on Download)  
Configuration upload:  
Upload the configuration by selecting a file and clicking Upload.  
Reset operation  
In order to activate the new configuration the system must be rebooted by  
entering the current IP address followed by a reset operation.  
v2.0 - English  
25  
OPERATION WITH INTERNET EXPLORER  
You must use Microsoft Internet Explorer from version 5, the Microsoft Java  
Virtual Machine and please disable the java script debugging.  
You need to install the MPEG ActiveX plugin.  
Your PC should support a video resolution of 1024 x 768 pixels.  
Connection  
Once you have configured your device, you may enter the IP address of the camera into  
the Internet Explorer address bar. (using 192.168.0.1 or http://192.168.0.1/ is acceptable.)  
Picture Dimensions (352 x 288 or 704 x 576 pixels)  
Alarm Input Status  
Relay  
Event Messages  
JPEG Snapshots  
Start or Stop Recording  
MPEG-4 Streams  
Alarm Messages  
v2.0 - English  
26  
Snapshot  
Individual images can be displayed in different resolutions. To select the resolution,  
append the corresponding parameter to the command snap.jpg:  
Ex: 192.168.0.1/snap.jpg  
Ø Snap.jpg?JpegSize=S 176 x 144 pixels  
Ø Snap.jpg?JpegSize=M 352 x 288 pixels  
(default value)  
Ø Snap.jpg?JpegSize=XL 704 x 576 pixels  
SERVICE  
The connection between two IP addresses can be checked using the command ping. You  
can thus check whether the device in the network is active.  
Ø Open the DOS input window and enter the command ping followed by the IP  
address of the device. (Ex: ping 192.168.0.1)  
Ø When the device is found, you receive in response: Reply from ..., followed by the  
number of bytes transmitted and the transmission time in milliseconds (ms). Other  
messages, such as a time out or unreachable, this indicates that the device cannot  
be addressed via the network. This can have the following causes:  
The device is not physically connected to the network. In this case, check the  
connecting leads, and the link lights on all devices. Or, perhaps the device is not  
correctly integrated into the network with its settings. Check the IP address, the  
subnet mask and the gateway IP.  
Reset  
In order to activate the new configuration the system must be rebooted by  
entering the current IP address followed by a reset operation:  
Updated Firmware Download  
You can find updated firmware for ZN-L8000 cameras at the following URL:  
v2.0 - English  
27  
TECHNICAL SPECIFICATIONS  
Video  
Model  
ZN-LN8048NHA  
ZN-LN8048PHA  
ZN-L8210PHA  
ZN-L8210NHA  
System  
NTSC/EIA (Day/Night)  
PAL/ CCIR (Day/Night)  
PAL  
NTSC  
Sensor  
Pixels  
Scanning System  
1/4" Interline Transfer CCD  
768(H) x 492(V) pixels  
752(H) x 582(V) pixels  
2:1 interlaced  
768(H) x 492(V) pixels  
Sync. System  
Internal  
(H) : 15.734KHz  
(V) :59.94Hz  
470 TVL  
(H) : 15.625KHz  
(V) :50.00Hz  
480 TVL  
(H) : 15.734KHz  
(V) :59.94Hz  
470 TVL  
Scanning freq.  
Res. (H)  
S/N ratio  
>50dB  
Sensitivity  
Gamma  
< 0.09 lux (F1.6) @ 30 IRE (Night Mode)  
< 1.5 lux (F1.2) @ 50 IRE  
0.45  
Video Output  
White Balance  
1.0Vp-p / 75O, BNC  
Auto Tracking  
Elect. Shutter 1/60 sec. fixed  
(1/100 sec. @ FL mode)  
1/60 (1/100 sec. @ FL mode)  
1/20,000 sec  
Elect. Shutter 1/50 sec. fixed  
(1/120 sec. @ FL mode)  
Elect. Shutter 1/60 sec fixed  
(1/100 sec. @ FL mode)  
1/60 (1/100 sec. @ FLmode)  
1/20,000 sec  
DC iris control  
AES  
1/50 (1/120 sec. @ FL mode) 1/20,000 sec  
Anti-Flicker On/Off, BLC On/Off,  
Night-Mode On/Off  
Controls  
Power  
Anti-Flicker On/Off, BLC On/Off  
Voltage 12VDC  
Power consumption 600mA max.  
Dimensions  
Dimensions  
(L) 180 x (W) 80.5 x (H) 59 mm  
Operation Temp. 40° ~ 115°F (5° ~ 45°C)  
Weight ~400 g (~0.9 lbs)  
Lens  
Model  
ZN-LN8048NHA  
4 ~ 7.5 mm  
F:1.6-360  
ZN-LN8048PHA  
ZN-L8210PHA  
2.8 ~ 10 mm  
@ 2.8 mm: 1.2 / @ 10 mm: 2.1  
ZN-L8210NHA  
Focal length  
F-stop  
Iris control  
DC  
Network  
Standard  
MPEG-4 (ISO/IEC 14496), M-JPEG  
adjustable – 4 Mbps max (MPEG-4)  
Bandwidth  
Video Encoder  
Audio  
176 x 144 QCIF / 352 x 288 CIF / 704 x 288 2CIF  
Datarate: 80 kbps / Standard: G.711; 300 Hz – 3.4 KHz  
1 x mono, 1Vp-p, 50K Ohm  
Audio input  
Audio Output  
Protocols  
Software update  
Configuration  
Alarm input  
Relay  
1 x mono, 1Vp-p, min 8 Ohm  
RTP, RTCP, UDP, TCP, IP, HTTP, IGMP, ICMP, ARP, DHCP, *FTP, *SNMP  
Flash ROM, remote site programmable  
using web browser (through built-in web server)  
2x, max 24V, max load 10 Ohm  
1x, max 40Vp-p, 0,8A  
USB  
* 1 x memory local storage or Wireless LAN (IEEE 802.11) connection  
10/100 Base-T, RJ45  
Ethernet  
* with future firmware update  
v2.0 - English  
28  
CBC (America) Corp.  
Imaging Technology Division  
New York Office  
Los Angeles Office  
55 Mall Drive  
20521 Earl Street  
Torrance, CA 90503  
Tel: 310 793 1500  
Fax: 310 793 1506  
Commack, NY 11725  
Tel.: 631 864 9700  
Fax: 631 543 5426  
v2.0 - English  
29  

Blaupunkt Orlando CD70 User Manual
Bosch Appliances GREENSTAR 28i junior User Manual
Canon Eos 70d 18 135 Is Stm Lens Kit 8469B016 User Manual
Draper Satellite TV System 3010 User Manual
Electrolux E24WC75HSS0 User Manual
Excalibur electronic JK01 User Manual
FujiFilm Camcorder DV108SA SA1 User Manual
HP (Hewlett Packard) LCD Monitor L1750 User Manual
JVC Digital Camcorder GZ EX210AUS User Manual
JVC GR FXM35 User Manual