Attwood Tsunami 69390 User Manual

Figure 1  
®
Thru-Hull Connector  
Hose & Clamp  
3
Tsunami Bilge Pump  
4606, 4608, 4612, 4613 Series  
Installation Instructions  
12" min. Above  
Water Line  
Base Strainer  
SAVE THESE INSTRUCTIONS  
Form Number 69390 Rev. A  
Hose MUST Rise  
Upward with NO DIP  
10-03  
Suitable Mounting Pad  
WARNING  
2. Do not mount pump directly to hull. Attach base strainer to a  
marine plywood mounting pad that is fiberglassed to the hull.  
Read all instructions carefully before installing and using this product.  
To prevent personal injury, disconnect the power source when installing  
or servicing this product. Always remove the boat from the water before  
using 120V AC power tools.  
HOSE CONNECTION INSTRUCTIONS  
IMPORTANT: To prevent airlock, hose must rise continually upward  
to the thru-hull connector with no dips or sharp bends. Support hose  
if necessary.  
DO NOT use pump to remove gasoline, oil or other flammable liquids.  
Always use the fuse amperage rating specified for your pump model.  
Failure to do so could result in serious personal injury or fire hazards.  
1. Orient pump outlet for a direct, unobstructed hose path.  
2. Secure all connections with hose clamps.  
3. If no thru-hull connector exists, install at 12" min. (25mm) above  
water line. Apply marine sealant around thru-hull flanges on  
interior and exterior of hull.  
Attwood bilge pumps are designed to exhaust STANDING WATER  
ONLY. They are not intended to prevent rapid accumulation of  
on-board water due to rough weather, hull damage, and/or other  
unsafe navigational conditions.  
Refer to Specification Chart to be sure you have selected the  
proper pump:  
PUMP MOUNTING INSTRUCTIONS  
1. To access mounting holes, remove base strainer. Hold housing with  
one hand, depress locking tab with other. Twist counter-clockwise  
and remove pump housing from base. It is not necessary to remove  
motor cartridge for installation. (Figure 2)  
12-Volt Models  
ABYC Specifications  
@13.6 VDC  
ISO Specifications  
@12 VDC  
(GPH = Gal. Per Hour) (LPH = Liters Per Hour)  
Figure 2  
0 ft.  
Head  
3.3 ft  
Head  
GPH/  
amps  
6.7 ft  
Head  
GPH/  
amps  
0kPa  
Head  
LPH/  
amps  
10kPa  
Head  
LPH/  
amps  
Max  
Head  
kPa@12v)  
Lock  
Part  
Outlet  
Num./  
Series  
Hose Motor Amp GPH/  
Unlock  
I.D.  
Cart. Fuse amps  
Motor  
Cartridge  
Tab  
4606/600 3/4"  
4608/800 3/4"  
4620 2.5A 500/1.5 400/ 1.5 250/1.5 1705/1.3 1250/1.3 8'/27  
Unlock  
Pump Housing  
4622 4A  
800/3.0 660/3.0 510/3.0 2840/2.5 2274/2.5 14'/33  
1200/3.5 900/3.5 700/3.5 4169/3.0 3000/3.0 11' 7"/28  
Lock  
4612/1200 1-1/8" 4624 5A  
24-Volt Models  
Motor Cartridge Replacement  
ABYC Specifications  
@24.0 VDC  
ISO Specifications  
@24.0 VDC  
(3) #8 Fasteners  
Base Strainer  
(GPH = Gal. Per Hour) (LPH = Liters Per Hour)  
Press Tab  
To Unlock  
0 ft.  
Head  
Amp GPH/  
Fuse amps  
3.3 ft  
Head  
GPH/  
amps  
6.7 ft  
Head  
GPH/  
amps  
0kPa  
Head  
LPH/  
amps  
10kPa  
Head  
LPH/  
amps  
Max  
Head  
(ft.@24v/  
kPa@24v)  
Part  
Num.  
Series  
1/8" Pilot Holes  
4609/800 3/4"  
4623 2A  
800/1.3 660/1.3 500/1.3 2842/1.1 2160/1.1 14'/31  
1200/1.5 900/1.5 725/1.5 4100/1.3 3100/1.3 11'/28  
4613/1200 1-1/8" 4625 2A  
2. Use base as template to mark 3 mounting holes in mounting pad.  
CAUTION: Do not drill through hull. Before drilling be sure mounted  
pump will be correctly positioned with pump nozzle pointing toward  
thru-hull connector. (Figure 1)  
MATERIALS REQUIRED  
• Three #8 stainless fasteners, suitable length for mounting surface  
• Cordless drill and 1/8" (3mm) bit  
• Hose clamps (Attwood # 9185, 2 per connection)  
• Mounting pad: marine plywood, fiberglass cloth and resin  
• Manual (# 7615A) or automatic float switch (#4201 or 4202)  
• Fuel-resistant, reinforced smooth bore outlet hose  
3. Remove base. Drill three 1/8" (3mm) pilot holes at marked locations.  
4. Replace base. Attach with #8 stainless steel fasteners.  
5. Re-attach pump to base. Insert into base, twist clockwise until tab  
snaps in and prevents turning. (Figure 2)  
WIRING INSTRUCTIONS  
Make all wire connections above the highest water level. Use marine  
grade wire connectors only. Waterproof all connections with suitable  
materials. (Figure 3)  
INSTALLATION LOCATION  
1. Position pump in the lowest accessible part of the bilge. On  
sailboats, location should be centered over keel. (Figure 1)  
NOTE: Failure to make waterproof connections and fuse pump properly  
will void the product warranty.  

Alphasonik PTZ25SE User Manual
Audiovox Rampage ACC 60 User Manual
Blaupunkt Car Stereo System TRUE User Manual
Citizen Calculator CT 555W User Manual
Crown Boiler KSZ150 User Manual
Eclipse Fujitsu Ten Car Stereo System CH3083 User Manual
Elmo Cable Box CBL CEL24 5 User Manual
Fujitsu Siemens Computers Rugged Tablet Case User Manual
Hifionics OLM1600D2 User Manual
JBL Professional JBL SR X Speakers 981 00052 02 User Manual