THE ANATOMY OF GREAT PERFORMANCE
A
E
Combustion
Venturi-mixing gas/air
ratio system works with
variable speed blower to
precisely mix gas and air
throughout firing range,
provides good operation
with supply gas pressures
down to 4˝ WC, and
air intake – self
adjusting-no air
shutter required
B
B
E
is self-adjusting for
EMC-5000
Modulating Control
altitudes up to 6,000
feet all while providing
low NOx emissions that
meet or exceed the most
stringent standards
A
C
D
Advanced pre-mix
burner design
precisely mixes
F
air and gas prior to
ignition for optimum
performance, with
low-NOx emissions
(meets SCAQMD
Rule 1146.2)
Heavy-duty ASME 160
psi copper finned tube
heat exchanger—Vertical,
straight tube, multi-pass
design surrounds the
burner with a 360° wall
of copper finned tubing,
making the entire heat
exchanger immune to
thermal shock
C
G
D
F
All non-heating
surface heat
exchanger compo-
nents are outside
and away from the
combustion and flue
collection areas;
only the copper fin
tubes are exposed
to the products of
combustion
G
D
The sealed heat
exchanger flue collection
system is constructed
of AL29-4C stainless
steel that is immune
to corrosive flue gases
COMMERCIAL GAS BOILERS
CATEGORY IV LISTED
PROFESSIONAL START-UP SERVICE FURNISHED
MEETS ASHRAE/IESNA 90.1-1999
LOW NOx OPERATION
Up To 88% Efficient,
Hot Water Supply
Boiler with
Modulating Fire
4:1 Turndown
I
Meets or exceeds Texas and California
SCAQMD Rule 1146.2 quality standards
™
OTHER VF BOILER FEATURES:
I
ASME Pressure Relief Valve 125#
I
Factory-Mounted Flow Switch
Hot Water Supply
Applications:
VW-500 through
VW-1000
I
Low Gas Pressure Switch
I
All Bronze Factory Mounted Pump
Standard on VW hot water supply models
I
Digital Inlet/Outlet Temperature Read Out
I
Manual Reset Hi-Limit
Hydronic Heating
Applications:
VB-500 through
VB-1000
WARRANTY:
I
5 Year Limited Heat Exchanger
Warranty on VW Models
I
10 Year Limited Heat Exchanger Warranty
on VB Models
™
VF BOILER APPROVED OPTIONS*
*For optional boiler equipment see VF Boiler VB and VW spec sheets.
Versatile Multi-Venting Configurations
I
Two-pipe direct-venting vertical and /or horizontal sidewall, with all
combustion makeup air drawn from outside the building
70 Equivalent Feet Exhaust
70 Equivalent Feet Intake
90 Degree Elbows = 10 Feet
45 Degree Elbows = 5 Feet
Boot Tee = 5 Feet
DIRECT-VENTING
I
Standard-venting, vertical or horizontal sidewall
100 Equivalent Feet Max
90 Degree Elbows = 10 Feet
45 Degree Elbows = 5 Feet
Boot Tee = 5 Feet
SIDEWALL
VENTING
CONVENTIONAL
VENTING
Please consult latest edition
of the Installation Manual for
detail venting information
and maximum/minimum
venting distances.
Advanced EMC-5000 Modulating Control
The EMC-5000 Modulating Control provides true self-diagnostic capabilities to eliminate
guesswork in troubleshooting. It is the most advanced boiler control we have ever offered,
setting a new standard for copper boilers.
EMC-5000 Modulating Control
I
Modulates the boiler to
maintain tank temperature
within +/- 1 degree
I
Infinite boiler output control
between 100% to 25% fire
I
LED read out – provides
current boiler status in
plain English with help
screens to assist should
a fault occur
I
Controls and monitors every
electrical boiler function with
onboard diagnostics
Small Size And
Easy Service
Small Footprints, Zero Clearance
To Combustibles On Sides of Unit
I
Compact design, lightweight
copper heat exchanger makes
VF Series easier to move and
install in limited spaces –
perfect for retrofits
I
Fits in an elevator, ideal for
boiler rooms with limited
access—only 30˝ wide
I
Multiple boiler systems provide
increased turndown and even
smoother, more efficient
system operation
I
4 boilers w/4:1 Turndown
=16:1 total system turndown
Model
No.
Input Rating
Btu/hr
Output Rating Gallons Per Hour Recovery Height
Width
Inches
Depth W/
Pump
Depth W/O
Pump
Approx.
Shipping
Btu/hr
Temperature Rise -°F
Inches
Inches
Inches
Weight (Lbs.)
40
100
140
362
VW/
VB-500
500,000
750,000
421,500
633,750
845,000
1,268 507
1,901 761
56
62
71
30
30
30
37.5
37.5
37.5
30
30
30
450
575
750
VW/
VB-750
543
VW/
VB-1000
1,000,000
2,535 1,014 724
Ac-U-Temp —A total hot water supply
system using VF Series Boilers
With Ac-U-Temp, A. O. Smith makes it as easy as possible
to install a complete packaged hot water supply system,
combining 88% efficient VF Series Boilers with A. O. Smith
storage tanks. A. O. Smith offers a wide range of available
boiler/storage tank combinations using the Ac-U-Temp
system. There are a number of standard boiler and tank
configurations with tanks up to 1,000 gallons, or we can
custom design and build an Ac-U-Temp system with tanks
up to 10,000 gallons to meet your specifications and
application requirements. Ac-U-Temp systems are shipped
fully assembled, pre-piped and pre-wired. All the installer
has to do is make the flue, gas, electrical and water
connections, so field errors are minimized.
Consult your A. O. Smith representative for more
information on the wide range of available boiler/storage
tank combinations using the Ac-U-Temp system.
Examples of
Ac-U-Temp
Systems
For complete specifications on the VF Series, consult the
local A. O. Smith sales representative.
500 Tennessee Waltz Parkway
Ashland City, TN 37015
•
ACGBR00307 ©2007 A. O. Smith Corporation
A. O. Smith reserves the right to make product changes or improvements at any time without notice.
Printed in U.S.A
|